This is a Limited Asbestos Inspection and Lead-Based Paint Survey report prepared by Hill West Environmental for the State of Utah Department of Administrative Services, Division of Facilities Construction and Management (DFCM), regarding the Division of Wildlife Resources Mammoth Creek Fish Hatchery located at 1306 Fish Hatchery Road in Hatch, Utah. The inspection, conducted on June 3, 2026, assessed building materials in the Office, Shop, Garage, and Raceway Buildings that will be impacted by planned upgrades including HVAC improvements, office upgrades, and lighting enhancements. The survey examined suspect materials including sheetrock wall systems, roof cores, caulk, block fillers, baseboards, window caulk, floor tile, and ceiling tile within the designated renovation areas only. The project manager, Ms. Aubrey Stapel, requested the inspection to identify asbestos-containing materials (ACM) and lead-based paint components requiring remediation before renovation activities commence.
The inspection results identified no asbestos-containing materials within the project upgrade areas and no lead detected in any building components within the upgrade area. However, the report identified universal, hazardous, and toxic wastes requiring management, including 22 fluorescent light bulbs and one rooftop air-conditioning unit containing CFCs that must be recycled by licensed contractors. The report specifies that if renovation or demolition contractors discover additional suspect materials not sampled during this inspection, work must cease and DFCM must be notified for further sampling and analysis. This pre-renovation assessment supports the larger Mammoth Creek Hatchery Improvements project (DFCM Project #27087520) with a construction cost estimate of $346,789.00, which includes office upgrades, lighting changes, generator upgrades, RV pad installation, mechanical upgrades, radon mitigation, and window upgrades with no changes to facility use, building sizes, or occupant loads.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED ASBESTOS INSPECTION
AND LEAD-BASED PAINT SURVEY
Division of Wildlife Resources Mammoth Creek Fish Hatchery
(Office, Shop, Garage, and Raceway Buildings)
1306 Fish Hatchery Road Hatch, Utah 84735
HVAC Upgrade, Office Upgrade, and Lighting Upgrades
July 13, 2026
Prepared for:
Ms. Aubrey Stapel
Project Manager, Statewide Programs
State of Utah
Department of Administrative Services
Division of Facilities Construction and Management (DFCM)
Taylorsville State Office Building
4315 South 2700 West, 3rd Floor
Taylorsville, Utah 84735-2128
Prepared by:
Hill West Environmental
7963 Douglas Drive
Hatch, Utah 84735
State of Utah Company Certification # ASBC-495
Claude Dahlk, CHMM, CIEC
(801) 450-8060
EXECUTIVE SUMMARY
On June 3, 2026, Hill West Environmental conducted a limited pre-renovation inspection for asbestos and lead-based paint of the Division of Wildlife Resources - Mammoth Creek Fish Hatchery (Office, Shop, Garage, and Raceway Buildings) located at 1306 Fish Hatchery Road, Hatch, Utah 84735.
The project includes upgrades to the HVAC Upgrade, Office Upgrade, and Lighting Upgrades within the project areas.
Ms. Aubrey Stapel, Project Manager with the State of Utah, Division of Facilities Construction and Management (DFCM) requested this inspection to identify asbestos-containing materials (ACM) and building components with lead-based paint that need to be addressed before the building is renovated.
The suspect materials sampled during the survey were sheetrock wall system, roof core, caulk, block filler, baseboard, window caulk, floor tile, and 1’ x 1’ ceiling tile that was sampled during the survey. Areas in which renovations are to occur were inspected, and all other areas were not inspected as part of this survey. Hill West has identified the following asbestos-containing materials (ACM) and lead-based paint during this inspection:
Asbestos-Containing Materials
Homogeneous Area Number
Material Description
Asbestos Content
Amount
Cost Estimate
N/A No ACM was identified in this survey N/A N/A N/A
Building Components with XRF Lead readings ≥ 0.4 mg/cm2
Material Type Reading (mg/cm2)
Lead was not detected within the project area. N/A
Universal, Hazardous, and Toxic Wastes
Material Type Quantity
Fluorescent Light Bulbs 22
Roof top A/C unit 1
Conclusions
ACM – No Asbestos Containing Materials (ACM) were identified within the project upgrade areas.
If the renovation or demolition contractor discovers additional suspect building materials that were not sampled as part of this inspection, they shall stop working and notify DFCM so that the materials can be sampled.
Lead – Lead was not detected within any building components within the upgrade area. If the renovation or demolition contractor discovers additional suspect building materials that were not sampled as part of this inspection that will be impacted, they shall stop working and notify DFCM so that the materials can be sampled.
Universal, Hazardous and Toxic Wastes – All Universal, Hazardous, and Toxic Wastes will need to be recycled by licensed contractors (CFCs in air handler on roof) impacted during this renovation project.
1.0 INTRODUCTION
As per DFCM’s instructions, Hill West Environmental conducted a limited asbestos and lead-based paint inspection of the Division of Wildlife Resources – Mammoth Creek Fish Hatchery (Office, Shop, Garage, and Raceway Buildings) located at 1306 Fish Hatchery Road, Hatch, Utah 84735. Due to the remodel and upgrades to the HVAC upgrade, office upgrade, and lighting upgrades, Hill West was instructed to only inspect areas that will be impacted during the renovation project.
The purpose of this survey was to identify the existence, extent, and condition of both friable and non-friable asbestos-containing materials (ACM) and lead-based paint/lead materials within the renovation areas.
2.0 SITE VISIT /OBSERVATIONS
2.1 Asbestos Inspection
On June 3, 2026, Hill West Environmental visited the site to survey the renovation areas of the building. A complete asbestos inspection of the areas that will be impacted during renovations was made to determine conditions and develop a sampling scheme for the areas. The materials that will be impacted during this upgrade project include sheetrock wall system, roof core, caulk, block filler, baseboard, window caulk, floor tile, and 1’x1’ ceiling tile Table 1 summarizes the asbestos inspection results.
Table 1 – Asbestos Materials
Homogenous Area Number
Material Description/Location Asbestos Content Amount Cost Estimate
N/A No ACM was identified in this survey of the upgrade areas.
N/A N/A N/A
Appendix A photographs of samples collected by Hill West Environmental and Site Map.
Appendix B contains analytical results and certifications.
2.2 Lead-based Paint Inspection
On June 3, 2026, Hill West Environmental conducted a limited lead-based paint inspection of the Division of Wildlife Resources – Mammoth Creek Fish Hatchery (Office, Shop, Garage, and Raceway Buildings)) within the project work area.
Direct measurement of lead in paint/dust were made using a Niton XL2 X-ray Fluorescence (XRF) Spectrum Analyzer. The Niton XRF non-destructively measures lead concentrations of painted surfaces, regardless of the number of layers present.
According to the manufacturer, the detection limit (lower limit of reliable measurement) for this instrument is 0.1 milligrams per square centimeter (mg/cm2) ±0.3 mg/cm2 with the instrument set on the “quick” measuring mode.
The quick mode provides 95% confidence that the lead concentration in the paint is above or below the set point of the instrument which, for this survey is 0.4 mg/cm2. For this survey, measurements below 0.4 mg/cm2 were not reported as lead containing.
The Niton XRF sometimes reports negative values. According to the manufacturer, negative values should be expected and interpreted as zero lead content due to the statistical variability of XRF measurement technology. Both HUD and the EPA recognize the statistical variability of XRF technology and the possibility of obtaining negative values where the lead content is near zero.
Table 2 summarizes the lead-based paint inspection results. Measurements are reported in milligrams of lead per square centimeter (mg/cm2). All the coatings tested during this inspection were in good to fair condition. Only positive readings (>0.4 mg/cm2) are summarized in Table 2. Appendix B contains all XRF readings for this survey.
Table 2 – Positive Lead-Based Paint/Lead Dust Readings
Building Component Material Description/Location Lead Content (mg/cm2)
N/A No lead was detected within the upgrade area. N/A
3.0 RESULTS
Table 3 summarizes the analytical results for the asbestos samples collected.
Table 3 – Asbestos Analytical Results
Sample Number
Homogeneous Area Number
Material Sampled Sample
Location Estimated Quantity*
Analytical Results
FH – 01A M001 Roof Core Roof <3,500 ft2 None Detected
FH – 01B M001 Roof Core Roof <3,500 ft2 None Detected
FH – 01C M001 Roof Core Roof <3,500 ft2 None Detected
FH – 01D M001 Roof Core Roof <1,000 ft2 None Detected
FH – 01E M001 Roof Core Roof <1,000 ft2 None Detected
FH – 02A M002 Black Caulk Office <30 ft2 None Detected
FH – 02B M002 Black Caulk Office <30 ft2 None Detected
FH – 02C M002 Black Caulk Office <30 ft2 None Detected
FH – 03A M003 1’ x 1’ Ceiling Tile Office <150 ft2 None Detected
FH – 03B M003 1’ x 1’ Ceiling Tile Office <150 ft2 None Detected
FH – 03C M003 1’ x 1’ Ceiling Tile Office <150 ft2 None Detected
FH – 04A S001 Exterior Brown Block Filler Office <1,000 ft2 None Detected
FH – 04B S001 Exterior Brown Block Filler Office <1,000 ft2 None Detected
Sample Number
Homogeneous Area Number
Material Sampled Sample
Location Estimated Quantity*
Analytical Results
FH – 04C S001 Exterior Brown Block Filler Office <1,000 ft2 None Detected
FH – 05A S002 Brown Block Filler Office <300 ft2 None Detected
FH – 05B S002 Brown Block Filler Office <300 ft2 None Detected
FH – 05C S002 Brown Block Filler Office <300 ft2 None Detected
FH – 06A M004 Brown Baseboard Office <50 linear feet None Detected
FH – 06B M004 Brown Baseboard Office <50 linear feet None Detected
FH – 06C M004 Brown Baseboard Office <50 linear feet None Detected
FH – 07A M005 Window Caulk Office <80 linear feet None Detected
FH – 07B M005 Window Caulk Office <80 linear feet None Detected
FH – 07C M005 Window Caulk Office <80 linear feet None Detected
FH – 08A M006 Beige Floor Tile Office <150 ft2 None Detected
FH – 08B M006 Beige Floor Tile Office <150 ft2 None Detected
FH – 08C M006 Beige Floor Tile Office <150 ft2 None Detected
FH – 09A M007 Sheetrock Wall System Garage Building <100 ft2 None Detected
FH – 09B M007 Sheetrock Wall System Garage Building <100 ft2 None Detected
FH – 09C M007 Sheetrock Wall System Garage Building <100 ft2 None Detected
* Estimated Quantity is based on amount to be disturbed during the upgrade project.
4.0 DISCUSSION/CONCLUSTIONS
In Utah, EPA asbestos regulations are administered by the Utah Division of Air Quality. Utah Occupational Safety and Health Administration (UOSHA) has adopted the Federal OSHA regulations. In addition, the Salt Lake Valley Health Department (SLVHD) regulates demolition activities in Salt Lake County. The SLVHD regulations for pre-demolition building inspections require an asbestos inspection, but also required building owners to inspect the building for other hazardous materials such as universal wastes, hazardous and toxic wastes and lead-based paint. Similar to asbestos, these wastes, if present must be removed prior to demolition/renovation.
A copy of this report should be on-site during all renovation activities.
This limited asbestos and lead-based paint inspection was conducted on the project area that will be impacted during renovation activities. Only items that are believed to be impacted during renovation activities were inspected during this survey. This survey is not intended to represent an exhaustive research of all asbestos or other hazards or conditions which may exist within other buildings located at this project site.
This report does not purport to represent future indoor conditions or events.
Situations or activities which transpire subsequent to this report, which result in adverse environmental, construction and/or engineering impacts, are not to be construed as relevant to this study.
This report is intended for the sole use of Hill West's client. This report may not be used or relied upon by any other party without the written consent of Hill West.
The scope of services performed in execution of the evaluation may not be appropriate to satisfy the needs of other users, and the use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user. Appendix B contains all Company certifications and individual inspector certifications.
Prepared by:
Claude Dahlk, CHMM, CIEC Asbestos Inspector ASB-0433
Appendix A
Photographs of Samples
Site Map
Mammoth Fish Hatchery
1306 Fish Hatchery Road
Hatch, Utah
FH – 01A Roof Core
FH – 01B Roof Core
FH – 01C Roof Core
FH – 01D Roof Core
FH – 01E Roof Core
FH – 02A Black Caulk
FH – 02B Black Caulk
FH – 02C Black Caulk
FH – 03A 12 Inch Ceiling Tile
FH – 03B 12 Inch Ceiling Tile
FH – 03C 12 Inch Ceiling Tile
FH – 04A Exterior Brown Block Filler
FH – 04B Exterior Brown Block Filler
FH – 04C Exterior Brown Block Filler
FH – 05A Brown Block Filler
FH – 05B Brown Block Filler
FH – 05C Brown Block Filler
FH – 06A Brown Baseboard
FH – 06B Brown Baseboard
FH – 06C Brown Baseboard
FH – 07A Window Caulk
FH – 07B Window Caulk
FH – 07C Window Caulk
FH – 08A Beige Floor Tile
FH – 08B Beige Floor Tile
FH – 08C Beige Floor Tile
FH – 09A Sheetrock Wall System
FH – 09B Sheetrock Wall System
FH – 09C Sheetrock Wall System
Lighting Being Replaced
Appendix B
Analytical Results
Certifications
Approved by:
Approved Signatory Renee Luna-Trepczynski
Report for:
Claude Dahlk Hill West Environmental, LLC 7963 Douglas Drive Park City, UT 84098
Regarding:
Eurofins Aerotech Built Environment Testing, LLC Project: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
EML ID: 4575315
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Aerotech Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 06-16-2026
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 500031-0
EMLab ID: 4575315, Page 1 of 10Eurofins Aerotech Built Environment Testing, LLC
Eurofins Aerotech Built Environment Testing, LLC 1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Total Samples Submitted: 29 Total Samples Analyzed: 29
Total Samples with Layer Asbestos Content > 1%: 0
Location: FH-01A, Roof Core Lab ID-Version‡: 23054994-1
Sample Layers Asbestos Content Black Roofing Material ND
Tan Mastic ND White Drywall with Gray Surface ND
Orange Non-Fibrous Material ND Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Poor
Location: FH-01B, Roof Core Lab ID-Version‡: 23054995-1
Sample Layers Asbestos Content Black Roofing Material ND
Black Roofing Material 2 ND Tan Mastic ND
White Drywall with Gray Surface ND Orange Non-Fibrous Material ND
Brown Roofing Felt ND Yellow Foam ND
Composite Non-Asbestos Content: 5% Glass Fibers 3% Cellulose
Sample Composite Homogeneity: Poor
EMLab ID: 4575315, Page 2 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-01C, Roof Core Lab ID-Version‡: 23054996-1
Sample Layers Asbestos Content Black Roofing Material ND
Tan Mastic ND White Drywall with Gray Surface ND
Brown Roofing Felt ND Yellow Foam ND
Composite Non-Asbestos Content: 5% Glass Fibers 3% Cellulose
Sample Composite Homogeneity: Poor
Location: FH-01D, Roof Core Lab ID-Version‡: 23054997-1
Sample Layers Asbestos Content Black Roofing Material ND
Tan Mastic ND Off-White Drywall with Gray Surface ND
Brown Roofing Felt ND Yellow Foam ND
Composite Non-Asbestos Content: 5% Glass Fibers 3% Cellulose
Sample Composite Homogeneity: Poor
Location: FH-01E, Roof Core Lab ID-Version‡: 23054998-1
Sample Layers Asbestos Content Black Roofing Material ND
Tan Mastic ND White Drywall with Gray Surface ND
Brown Roofing Felt ND Yellow Foam ND
Composite Non-Asbestos Content: 5% Glass Fibers 3% Cellulose
Sample Composite Homogeneity: Poor
EMLab ID: 4575315, Page 3 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-02A, Black Caulk Lab ID-Version‡: 23054999-1
Sample Layers Asbestos Content Black Caulk ND
Sample Composite Homogeneity: Good
Location: FH-02B, Black Caulk Lab ID-Version‡: 23055000-1
Sample Layers Asbestos Content Black Caulk ND
Sample Composite Homogeneity: Good
Location: FH-02C, Black Caulk Lab ID-Version‡: 23055001-1
Sample Layers Asbestos Content Black Caulk ND
Sample Composite Homogeneity: Good
Location: FH-03A, 12 inch ceiling tile Lab ID-Version‡: 23055002-1
Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND
Brown Mastic ND Composite Non-Asbestos Content: 80% Cellulose Sample Composite Homogeneity: Moderate
Location: FH-03B, 12 inch ceiling tile Lab ID-Version‡: 23055003-1
Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND
Composite Non-Asbestos Content: 80% Cellulose Sample Composite Homogeneity: Good
EMLab ID: 4575315, Page 4 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-03C, 12 inch ceiling tile Lab ID-Version‡: 23055004-1
Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND
Brown Mastic ND Composite Non-Asbestos Content: 80% Cellulose Sample Composite Homogeneity: Moderate
Location: FH-04A, Exterior Brown Block Filler Lab ID-Version‡: 23055005-1
Sample Layers Asbestos Content Gray Cementitious Material with Paint Layers ND
Sample Composite Homogeneity: Moderate Comments: Described Block Filler not observed in submitted sample.
Location: FH-04B, Exterior Brown Block Filler Lab ID-Version‡: 23055006-1
Sample Layers Asbestos Content Gray Cementitious Material with Paint Layers ND
Sample Composite Homogeneity: Moderate Comments: Described Block Filler not observed in submitted sample.
Location: FH-04C, Exterior Brown Block Filler Lab ID-Version‡: 23055007-1
Sample Layers Asbestos Content Gray Cementitious Material with Paint Layers ND
Sample Composite Homogeneity: Moderate Comments: Described Block Filler not observed in submitted sample.
EMLab ID: 4575315, Page 5 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-05A, Brown Block Filler Lab ID-Version‡: 23055008-1
Sample Layers Asbestos Content Tan Block Filler with Paint ND
Gray Block with Paint ND Gray Mortar with Paint ND
Sample Composite Homogeneity: Poor
Location: FH-05B, Brown Block Filler Lab ID-Version‡: 23055009-1
Sample Layers Asbestos Content Tan Block Filler with Paint ND
Gray Block with Paint ND Gray Mortar with Paint ND
Sample Composite Homogeneity: Poor
Location: FH-05C, Brown Block Filler Lab ID-Version‡: 23055010-1
Sample Layers Asbestos Content Tan Block Filler with Paint ND
Gray Block with Paint ND Gray Mortar with Paint ND
Sample Composite Homogeneity: Poor
Location: FH-06A, Brown Baseboard Lab ID-Version‡: 23055011-1
Sample Layers Asbestos Content Brown Baseboard ND
Cream Mastic ND Sample Composite Homogeneity: Moderate
EMLab ID: 4575315, Page 6 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-06B, Brown Baseboard Lab ID-Version‡: 23055012-1
Sample Layers Asbestos Content Brown Baseboard ND
Cream Mastic ND Brown Mastic ND
Sample Composite Homogeneity: Poor
Location: FH-06C, Brown Baseboard Lab ID-Version‡: 23055013-1
Sample Layers Asbestos Content Brown Baseboard ND
Cream Mastic ND Sample Composite Homogeneity: Moderate
Location: FH-07A, Window Caulk Lab ID-Version‡: 23055014-1
Sample Layers Asbestos Content Brown/Gray Caulk ND
Sample Composite Homogeneity: Good
Location: FH-07B, Window Caulk Lab ID-Version‡: 23055015-1
Sample Layers Asbestos Content Brown/Gray Caulk ND
Sample Composite Homogeneity: Good
EMLab ID: 4575315, Page 7 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-07C, Window Caulk Lab ID-Version‡: 23055016-1
Sample Layers Asbestos Content Brown/Gray Caulk ND
Sample Composite Homogeneity: Good
Location: FH-08A, Beige Floor Tile Lab ID-Version‡: 23055017-1
Sample Layers Asbestos Content Beige Floor Tile ND
Tan Mastic ND Sample Composite Homogeneity: Moderate
Location: FH-08B, Beige Floor Tile Lab ID-Version‡: 23055018-1
Sample Layers Asbestos Content Beige Floor Tile ND
Sample Composite Homogeneity: Good Comments: Tan Mastic observed; Insufficient material present for analysis.
Location: FH-08C, Beige Floor Tile Lab ID-Version‡: 23055019-1
Sample Layers Asbestos Content Beige Floor Tile ND
Tan Mastic ND Sample Composite Homogeneity: Moderate
EMLab ID: 4575315, Page 8 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
Location: FH-09A, Sheet rock wall system Lab ID-Version‡: 23058541-1
Sample Layers Asbestos Content White Compound with Paint ND
Cream Tape ND White Joint Compound ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Location: FH-09B, Sheet rock wall system Lab ID-Version‡: 23058542-1
Sample Layers Asbestos Content White Compound with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: FH-09C, Sheet rock wall system Lab ID-Version‡: 23058543-1
Sample Layers Asbestos Content White Compound with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
EMLab ID: 4575315, Page 9 of 10Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Mammoth Fish Hatchery; 1306 Fish Hatchery Rocio, Hatch, UT
Date of Sampling: 06-03-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026
ASBESTOS PLM REPORT
PROJECT ANALYST AND SIGNATORY REPORT
Project Analyst
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
Analyst: Kaitlyn Jones
EMLab ID: 4575315, Page 10 of 10Eurofins Aerotech Built Environment Testing, LLC
Inspector: Dominic Hobbs
Date Inspected: 6-3-2026
PB-2781
Limited-Lead Based Paint Readings Mammoth Fish Hatchery
Index Time Results Component Substrate Condition Color Building PbC
10 6/3/2026 17:08 Positive CALABRATE 1.17
11 6/3/2026 17:08 Positive CALABRATE 1.13
12 6/3/2026 17:09 Positive CALABRATE 1.14
13 6/3/2026 17:09 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
14 6/3/2026 17:09 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
15 6/3/2026 17:09 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
16 6/3/2026 17:09 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
17 6/3/2026 17:09 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
18 6/3/2026 17:10 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
19 6/3/2026 17:10 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
20 6/3/2026 17:10 Negative WALL CMU BRICK FAIR BEIGE Office <LOD
21 6/3/2026 17:10 Negative CABINETS WOOD FAIR BEIGE Office 0.12
22 6/3/2026 17:10 Negative CABINETS WOOD FAIR BEIGE Office <LOD
23 6/3/2026 17:10 Negative CABINETS WOOD FAIR BEIGE Office <LOD
24 6/3/2026 17:11 Negative CABINETS WOOD FAIR BEIGE Office <LOD
25 6/3/2026 17:11 Negative CABINETS WOOD FAIR BEIGE Office <LOD
26 6/3/2026 17:11 Negative CABINETS WOOD FAIR BEIGE Office <LOD
27 6/3/2026 17:11 Negative TRIM METAL FAIR BROWN Office <LOD
28 6/3/2026 17:11 Negative TRIM METAL FAIR BROWN Office <LOD
29 6/3/2026 17:11 Negative TRIM METAL FAIR BROWN Office 0.26
30 6/3/2026 17:12 Negative TRIM METAL FAIR BROWN Office <LOD
31 6/3/2026 17:12 Negative DOOR METAL FAIR BROWN Office <LOD
32 6/3/2026 17:12 Negative DOOR METAL FAIR BROWN Office <LOD
33 6/3/2026 17:12 Negative DOOR METAL FAIR BROWN Office 0.22
34 6/3/2026 17:12 Negative DOOR METAL FAIR BROWN Office <LOD
35 6/3/2026 17:12 Negative DOOR METAL FAIR BROWN Office <LOD
Inspector: Dominic Hobbs
Date Inspected: 6-3-2026
PB-2781
Limited-Lead Based Paint Readings Mammoth Fish Hatchery
Index Time Results Component Substrate Condition Color Building PbC
36 6/3/2026 17:13 Negative WINDOW METAL FAIR BROWN Office <LOD
37 6/3/2026 17:13 Negative WINDOW METAL FAIR BROWN Office <LOD
38 6/3/2026 17:13 Negative WINDOW METAL FAIR BROWN Office <LOD
39 6/3/2026 17:13 Negative WINDOW METAL FAIR WHITE Office <LOD
40 6/3/2026 17:14 Negative WINDOW METAL FAIR WHITE Office <LOD
41 6/3/2026 17:14 Negative WINDOW METAL FAIR WHITE Office <LOD
42 6/3/2026 17:15 Negative EXTERIOR WALL CMU BRICK FAIR BEIGE Office <LOD
43 6/3/2026 17:15 Negative EXTERIOR WALL CMU BRICK FAIR BEIGE Office <LOD
44 6/3/2026 17:15 Negative EXTERIOR WALL CMU BRICK FAIR BEIGE Office <LOD
45 6/3/2026 17:16 Negative TRIM CMU BRICK FAIR BROWN Office <LOD
46 6/3/2026 17:16 Negative TRIM CMU BRICK FAIR BROWN Office <LOD
47 6/3/2026 17:16 Negative TRIM CMU BRICK FAIR BROWN Office <LOD
48 6/3/2026 17:20 Negative FRAME METAL FAIR BROWN Storage Room <LOD
49 6/3/2026 17:20 Negative FRAME METAL FAIR BROWN Raceway <LOD
50 6/3/2026 17:24 Negative WALL DRYWALL FAIR BEIGE Garage <LOD
51 6/3/2026 17:24 Negative WALL DRYWALL FAIR BEIGE Garage <LOD
52 6/3/2026 17:25 Negative WALL DRYWALL FAIR BEIGE Garage <LOD
53 6/3/2026 17:25 Negative WALL DRYWALL FAIR BEIGE Garage <LOD
54 6/3/2026 17:25 Negative WALL DRYWALL FAIR BEIGE Garage <LOD
55 6/3/2026 17:25 Negative WALL DRYWALL FAIR BEIGE Garage <LOD
56 6/3/2026 17:29 Positive CALABRATE 0.75
57 6/3/2026 17:29 Positive CALABRATE 1.01
58 6/3/2026 17:29 Negative CALABRATE 0.94
| Mammoth Fish Hatechery Upgrades Limited Haz Mat Report 06 18 2026 |
| ACM Photo Log Mammoth Fish Hatchery 06 18 26 |
| Figure 1 Mammoth Creek Labeled |
| Mammoth Fish Hatechery Upgrades Limited Haz Mat Report 06 18 2026 |
| Project-4575315_Mammoth Fish Hatchery |
| Copy of Copy of Mammoth Fish Hatchery Lead 07 07 26_ |
| 2026 Dahlk Hobbs HW ACM Lead Certs |
| scan_20260108062842 |
| 2025 Dahlk Hobbs HW ACM Lead Certs |
| 2024 Dahlk HW Hobbs Asbestos Certs |
| 2025 Dahlk Hobbs HW ACM Lead Certs |
| Hill West Lead Cert 2026 |
File details come from the government source that posted it. Updated .