8-2026-09-25 - Dunmore Carpet Factory Renovation- Add 05.pdf

PDF 252 KB Posted

Attached to
Dunmore Carpet Factory Renovation and Site Work Project
Solicitation number
Not on record
Issued by
Lackawanna County, Pennsylvania

About this file

Summary

This is Addendum #05 to the door hardware specification section (087100) for the Dunmore Carpet Factory Renovation and Site Work Project, issued by ALLOY5, LLC on behalf of Hoofty Holdings. The addendum extends the bid deadline to Tuesday, October 6, 2026, at 2:00 P.M. prevailing time and provides clarifications on exterior brick repointing, appliance supply responsibility, electrical demolition scope, door hardware scheduling, and mixed air ductwork definitions. The comprehensive specification section 087100 establishes requirements for mechanical and electrified door hardware, electronic access control system components, hinges, continuous hinges, cylindrical locks, exit devices, electronic programmable interconnected locksets, power supplies, door closers, thresholds, and related hardware. The hardware schedule details 16 hardware groups with specific manufacturers and products, including scheduled manufacturers such as Schlage, Falcon, LCN, Von Duprin, and Ives, with acceptable alternate manufacturers specified for most items. The project requires submission of detailed door hardware schedules prepared by a DHI-certified Architectural Hardware Consultant, product data, wiring diagrams, samples, keying schedules, and compliance certifications for fire-rated assemblies.

The specification mandates single-source responsibility for each hardware type to ensure compatibility and continuity of maintenance standards. Quality assurance requirements include a minimum of five years' documented experience for hardware suppliers, qualified installers, and DHI-certified consultants available during the work. Warranty periods vary by manufacturer and product type, ranging from one year for electrical components to 25 years for certain door closers such as the LCN 4050 Series. The project requires a mandatory keying conference and pre-installation conference prior to construction, coordination with electrical and security systems, and post-installation functional testing and inspection in compliance with NFPA 80 and NFPA 101. Approximately 300 access control credentials in black finish are specified as miscellaneous items. Installation must follow DHI guidelines and manufacturer specifications, with hardware mounted at heights complying with ANSI standards and accessibility requirements. A key control system with capacity for 150 percent of project locks and maintenance data including care instructions and replacement parts information must be provided at project closeout.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM #05

ALLOY5, LLC

530 WEST BROAD STREET

BETHLEHEM, PA 18018

WWW.ALLOY5.COM

PROJECT: DUNMORE CARPET FACTORY RENOVATION AND SITE WORK PROJECT

BIDS DUE TO: PennBid

BIDS DUE: TUESDAY, OCTOBER 6TH, 2026 @ 2:00 P.M. PREVAILING TIME

DATE: FRIDAY, SEPTEMBER 25, 2026

The following clarifications, amendments, additions, deletions, revisions and modifications in this Addendum forms a part of the Contract Documents and modifies the original Bidding Documents as noted below. This addendum must be acknowledged in the form of proposal in the space provided for this purpose. Failure to acknowledge this addendum may subject the Bidder to disqualifications.

GENERAL

1. The deadline for bids has been extended until Tuesday, October 6, 2026 at 2:00 P.M.

2. REMINDER: Project Allowances (Unit Prices) to be included in the Base Bid Cost. Owner would like to see the combined cost of the project separate from the Grand Total cost.

DRAWINGS

Revised Drawings

New Drawings

SPECIFICATIONS

New Specification Sections:

1. 087100 DOOR HARDWARE

Revised Specification Sections:

Questions:

5.1 On the Structural Elevations it is depicted that there are areas of the exterior elevations which are to be repointed. On the Architectural elevations it’s called out to be "Existing Exterior brick to be repointed and repaired. See Structural Drawings for Extents of Brick Repair"

Does this mean that all of the building is being repointed and were referring to the structural drawings for repair? It is conflicting between the Structural and Architectural please advise.

Answer: To clarify, this means that the building is to be repointed in the area outlined on the elevations found in the Structural Elevation Drawings.

5.2 Is the supply of the Appliances the responsibility of the General Contractor.

Answer: Appliances are the responsibility of the GC. Please see drawing A7.40 for

Manufactures and Model Numbers.

5.3 The architectural Demo drawings have notes that say to reference Electrical Demo drawings for more info, but I do not see any electrical demo drawings. Is this just a cut and paste note or am I missing drawings.

Answer: The electrical receptacles, switches, loose wiring, and wire mold track is to be removed as indicated on the Architectural Demolition Drawings from the walls that are scheduled to remain. The statement “Refer to elec. Demo dwg for more info” can be ignored in Key Note 15.

5.4 Will there be a door hardware schedule for this project.

Answer: See attached specification section “087100 Door Hardware”

5.5 Per addendum# 2 what is mixed air ductwork?

Answer: The term "mixed air ductwork" appears in our specifications for Ductwork and

Ductwork Insulation, and is just referring to any sections of duct where outdoor ventilation air mixes with return air, before being supplied through an HVAC system.

Typically, a VTAC would have a mixing box or plenum box on the intake side where the ventilation air from outside mixes with the return air already in the space. That section would be considered the "mixed air" going into the units to be conditioned for the space.

DOOR HARDWARE 087100-1

09/25/2026

SECTION 087100 - DOOR HARDWARE

PART 1 - GENERAL

1.01 SUMMARY

A. Section includes:

1. Mechanical and electrified door hardware

2. Electronic access control system components

B. Section excludes:

1. Windows

2. Cabinets (casework), including locks in cabinets

3. Signage

4. Toilet accessories

5. Overhead doors

C. Related Sections:

1. Division 01 "General Requirements" sections for Allowances, Alternates, Owner

Furnished Contractor Installed, Project Management and Coordination.

2. Division 06 Section ''Rough Carpentry''

3. Division 06 Section ''Finish Carpentry''

4. Division 07 Section ''Joint Sealants'' for sealant requirements applicable to threshold installation specified in this section.

5. Division 08 Sections:

a. ''Metal Doors and Frames''

b. ''Flush Wood Doors''

c. ''Aluminum-Framed Entrances and Storefronts''

6. Division 26 ''Electrical'' sections for connections to electrical power system and for low-voltage wiring.

7. Division 28 ''Electronic Safety and Security'' sections for coordination with other components of electronic access control system and fire alarm system.

1.02 REFERENCES

A. UL LLC

1. UL 10B - Fire Test of Door Assemblies

2. UL 10C - Positive Pressure Test of Fire Door Assemblies

3. UL 1784 - Air Leakage Tests of Door Assemblies

4. UL 305 - Panic Hardware

B. DHI - Door and Hardware Institute

1. Sequence and Format for the Hardware Schedule

2. Recommended Locations for Builders Hardware

3. Keying Systems and Nomenclature

4. Installation Guide for Doors and Hardware

DOOR HARDWARE 087100-2

C. NFPA – National Fire Protection Association

1. NFPA 70 – National Electric Code

2. NFPA 80 – Standard for Fire Doors and Other Opening Protectives

3. NFPA 101 – Life Safety Code

4. NFPA 105 – Smoke and Draft Control Door Assemblies

5. NFPA 252 – Fire Tests of Door Assemblies

D. ANSI - American National Standards Institute

1. ANSI A117.1 – 2017 Edition – Accessible and Usable Buildings and Facilities

2. ANSI/BHMA A156.1 - A156.29, and ANSI/BHMA A156.31 - Standards for Hardware and Specialties

3. ANSI/BHMA A156.28 - Recommended Practices for Keying Systems

4. ANSI/WDMA I.S. 1A - Interior Architectural Wood Flush Doors

5. ANSI/SDI A250.8 - Standard Steel Doors and Frames

1.03 SUBMITTALS

A. General:

1. Submit in accordance with Conditions of Contract and Division 01 Submittal Procedures.

2. Prior to forwarding submittal:

a. Review drawings and Sections from related trades to verify compatibility with specified hardware.

b. Highlight, encircle, or otherwise specifically identify on submittals: deviations from

Contract Documents, issues of incompatibility or other issues which may detrimentally affect the Work.

B. Action Submittals:

1. Product Data: Submit technical product data for each item of door hardware, installation instructions, maintenance of operating parts and finish, and other information necessary to show compliance with requirements.

2. Riser and Wiring Diagrams: After final approval of hardware schedule, submit details of electrified door hardware, indicating:

a. Wiring Diagrams: For power, signal, and control wiring and including:

1) Details of interface of electrified door hardware and building safety and security systems.

2) Schematic diagram of systems that interface with electrified door hardware.

3) Point-to-point wiring.

4) Risers.

3. Samples for Verification: If requested by Architect, submit production sample of requested door hardware unit in finish indicated and tagged with full description for coordination with schedule.

a. Samples will be returned to supplier. Units that are acceptable to Architect may, after final check of operations, be incorporated into Work, within limitations of key coordination requirements.

4. Door Hardware Schedule:

a. Submit concurrent with submissions of Product Data, Samples, and Shop Drawings.

Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate fabrication of other work critical in Project construction schedule.

DOOR HARDWARE 087100-3

b. Submit under direct supervision of a Door Hardware Institute (DHI) certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) with hardware sets in vertical format as illustrated by Sequence of Format for the Hardware Schedule published by DHI.

c. Indicate complete designations of each item required for each opening, include:

1) Door Index: door number, heading number, and Architect's hardware set number.

2) Quantity, type, style, function, size, and finish of each hardware item.

3) Name and manufacturer of each item.

4) Fastenings and other pertinent information.

5) Location of each hardware set cross-referenced to indications on Drawings.

6) Explanation of all abbreviations, symbols, and codes contained in schedule.

7) Mounting locations for hardware.

8) Door and frame sizes and materials.

9) Degree of door swing and handing.

10) Operational Description of openings with electrified hardware covering egress, ingress (access), and fire/smoke alarm connections.

5. Key Schedule:

a. After Keying Conference, provide keying schedule that includes levels of keying, explanations of key system's function, key symbols used, and door numbers controlled.

b. Use ANSI/BHMA A156.28 ''Recommended Practices for Keying Systems'' as guideline for nomenclature, definitions, and approach for selecting optimal keying system.

c. Provide 3 copies of keying schedule for review prepared and detailed in accordance with referenced DHI publication. Include schematic keying diagram and index each key to unique door designations.

d. Index keying schedule by door number, keyset, hardware heading number, cross keying instructions, and special key stamping instructions.

e. Provide one complete bitting list of key cuts and one key system schematic illustrating system usage and expansion. Forward bitting list, key cuts and key system schematic directly to Owner, by means as directed by Owner.

f. Prepare key schedule by or under supervision of supplier, detailing Owner's final keying instructions for locks.

C. Informational Submittals:

1. Provide Qualification Data for Supplier, Installer and Architectural Hardware Consultant.

2. Provide Product Data:

a. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.

b. Include warranties for specified door hardware.

D. Closeout Submittals:

1. Operations and Maintenance Data: Provide in accordance with Division 01 and include:

a. Complete information on care, maintenance, and adjustment; data on repair and replacement parts, and information on preservation of finishes.

b. Catalog pages for each product.

c. Final approved hardware schedule edited to reflect conditions as installed.

d. Final keying schedule

e. Copy of warranties including appropriate reference numbers for manufacturers to identify project.

f. As-installed wiring diagrams for each opening connected to power, both low voltage and 110 volts.

DOOR HARDWARE 087100-4

E. Inspection and Testing:

1. Submit written reports to the Owner and Authority Having Jurisdiction (AHJ) of the results of functional testing and inspection for:

a. Fire door assemblies, in compliance with NFPA 80.

b. Required egress door assemblies, in compliance with NFPA 101.

1.04 QUALITY ASSURANCE

A. Qualifications and Responsibilities:

1. Supplier: Recognized architectural hardware supplier with a minimum of 5 years documented experience supplying both mechanical and electromechanical door hardware similar in quantity, type, and quality to that indicated for this Project. Supplier to be recognized as a factory direct distributor by the manufacturer of the primary materials with a warehousing facility in the Project’s vicinity. Supplier to have on staff, a certified

Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) available to Owner, Architect, and Contractor, at reasonable times during the Work for consultation.

2. Installer: Qualified tradesperson skilled in the application of commercial grade hardware with experience installing door hardware similar in quantity, type, and quality as indicated for this Project.

3. Architectural Hardware Consultant: Person who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project and meets these requirements:

a. For door hardware: DHI certified AHC or DHC.

b. Can provide installation and technical data to Architect and other related subcontractors.

c. Can inspect and verify components are in working order upon completion of installation.

d. Capable of producing wiring diagram and coordinating installation of electrified hardware with Architect and electrical engineers.

4. Single Source Responsibility: Obtain each type of door hardware from single manufacturer.

B. Certifications:

1. Fire-Rated Door Openings:

a. Provide door hardware for fire-rated openings that complies with NFPA 80 and requirements of authorities having jurisdiction.

b. Provide only items of door hardware that are listed products tested by UL LLC, Intertek Testing Services, or other testing and inspecting organizations acceptable to authorities having jurisdiction for use on types and sizes of doors indicated, based on testing at positive pressure and according to NFPA 252 or UL 10C and in compliance with requirements of fire-rated door and door frame labels.

2. Smoke and Draft Control Door Assemblies:

a. Provide door hardware that meets requirements of assemblies tested according to

UL 1784 and installed in compliance with NFPA 105

b. Comply with the maximum air leakage of 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) at tested pressure differential of 0.3-inch wg (75 Pa) of water.

3. Electrified Door Hardware

a. Listed and labeled as defined in NFPA 70, Article 100, by testing agency acceptable to authorities having jurisdiction.

DOOR HARDWARE 087100-5

4. Accessibility Requirements:

a. Comply with governing accessibility regulations cited in ''REFERENCES'' article

087100, 1.02.D3 herein for door hardware on doors in an accessible route. This project must comply with all Federal Americans with Disability Act regulations and all Local Accessibility Regulations.

C. Pre-Installation Meetings

1. Keying Conference

a. Incorporate keying conference decisions into final keying schedule after reviewing door hardware keying system including:

1) Function of building, flow of traffic, purpose of each area, degree of security required, and plans for future expansion.

2) Preliminary key system schematic diagram.

3) Requirements for key control system.

4) Requirements for access control.

5) Address for delivery of keys.

2. Pre-installation Conference

a. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.

b. Inspect and discuss preparatory work performed by other trades.

c. Inspect and discuss electrical roughing-in for electrified door hardware.

d. Review sequence of operation for each type of electrified door hardware.

e. Review required testing, inspecting, and certifying procedures.

f. Review questions or concerns related to proper installation and adjustment of door hardware.

3. Electrified Hardware Coordination Conference:

a. Prior to ordering electrified hardware, schedule and hold meeting to coordinate door hardware with security, electrical, doors and frames, and other related suppliers.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Inventory door hardware on receipt and provide secure lock-up for hardware delivered to Project site. Promptly replace products damaged during shipping

B. Tag each item or package separately with identification coordinated with final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package. Deliver each article of hardware in manufacturer's original packaging.

C. Maintain manufacturer-recommended environmental conditions throughout storage and installation periods.

D. Provide secure lock-up for door hardware delivered to Project. Control handling and installation of hardware items so that completion of Work will not be delayed by hardware losses both before and after installation.

E. Handle hardware in manner to avoid damage, marring, or scratching. Correct, replace or repair products damaged during Work. Protect products against malfunction due to paint, solvent, cleanser, or any chemical agent.

F. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.

DOOR HARDWARE 087100-6

1.06 COORDINATION

A. Coordinate layout and installation of floor-recessed door hardware with floor construction.

Cast anchoring inserts into concrete.

B. Installation Templates: Distribute for doors, frames, and other work specified to be factory or shop prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

C. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant.

D. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.

1.07 WARRANTY

A. Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within published warranty period.

1. Warranty does not cover damage or faulty operation due to improper installation, improper use or abuse.

2. Warranty Period: Beginning from date of Substantial Completion, for durations indicated in manufacturer's published listings.

a. Mechanical Warranty

1) Locks

a) Schlage ND Series: 10 years

b) Schlage ALX Series: 10 years

2) Exit Devices

a) Falcon: 10 years

3) Closers

a) LCN 4050 Series: 25 years

b. Electrical Warranty

1) Exit Devices

a) Falcon: 1 Year

1.08 MAINTENANCE

A. Furnish complete set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.

B. Turn over unused materials to Owner for maintenance purposes.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

DOOR HARDWARE 087100-7

A. The Owner requires use of certain products for their unique characteristics and project suitability to ensure continuity of existing and future performance and maintenance standards. After investigating available product offerings, the Awarding Authority has elected to prepare proprietary specifications. These products are specified with the notation: ''No Substitute.''

1. Where ''No Substitute'' is noted, submittals and substitution requests for other products will not be considered.

B. Approval of alternate manufacturers and/or products other than those listed as ''Scheduled Manufacturer'' or ''Acceptable Manufacturers'' in the individual article for the product category are only to be considered by official substitution request in accordance with section 01 25 00.

C. Approval of products from manufacturers indicated in ''Acceptable Manufacturers'' is contingent upon those products providing all functions and features and meeting all requirements of scheduled manufacturer's product.

D. Where specified hardware is not adaptable to finished shape or size of members requiring hardware, furnish suitable types having same operation and quality as type specified, subject to Architect's approval.

2.02 MATERIALS

A. Fabrication

1. Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. provide screws according to manufacturer’s recognized installation standards for application intended.

2. Finish exposed screws to match hardware finish, or, if exposed in surfaces of other work, to match finish of this other work including prepared for paint surfaces to receive painted finish.

3. Provide concealed fasteners wherever possible for hardware units exposed when door is closed. Coordinate with “Metal Doors and Frames”, “Flush Wood Doors”, “Stile and Rail

Wood Doors” to ensure proper reinforcements. Advise the Architect where visible fasteners, such as thru bolts, are required.

B. Provide screws, bolts, expansion shields, drop plates and other devices necessary for hardware installation.

1. Where fasteners are exposed to view: Finish to match adjacent door hardware material.

C. Cable and Connectors:

1. Where scheduled in the hardware sets, provide each item of electrified hardware and wire harnesses with number and gage of wires enough to accommodate electric function of specified hardware.

2. Provide Molex connectors that plug directly into connectors from harnesses, electric locking and power transfer devices.

3. Provide through-door wire harness for each electrified locking device installed in a door and wire harness for each electrified hinge, electrified continuous hinge, electrified pivot, and electric power transfer for connection to power supplies.

2.03 HINGES

DOOR HARDWARE 087100-8

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Ives 5BB series

2. Acceptable Manufacturers and Products:

a. Hager BB1191/1279 series

b. McKinney TB series

B. Requirements:

1. Provide hinges conforming to ANSI/BHMA A156.1.

2. Provide five knuckle, ball bearing hinges.

3. 1-3/4 inch (44 mm) thick doors, up to and including 36 inches (914 mm) wide:

a. Exterior: Standard weight, bronze or stainless steel, 4-1/2 inches (114 mm) high

b. Interior: Standard weight, steel, 4-1/2 inches (114 mm) high

4. 1-3/4 inch (44 mm) thick doors over 36 inches (914 mm) wide:

a. Exterior: Heavy weight, bronze/stainless steel, 5 inches (127 mm) high

b. Interior: Heavy weight, steel, 5 inches (127 mm) high

5. 2 inches or thicker doors:

a. Exterior: Heavy weight, bronze or stainless steel, 5 inches (127 mm) high

b. Interior: Heavy weight, steel, 5 inches (127 mm) high

6. Adjust hinge width for door, frame, and wall conditions to allow proper degree of opening.

7. Provide three hinges per door leaf for doors 90 inches (2286 mm) or less in height, and one additional hinge for each 30 inches (762 mm) of additional door height.

8. Hinge Pins: Except as otherwise indicated, provide hinge pins as follows:

a. Steel Hinges: Steel pins

b. Non-Ferrous Hinges: Stainless steel pins

c. Out-Swinging Exterior Doors: Non-removable pins

d. Out-Swinging Interior Lockable Doors: Non-removable pins

e. Interior Non-lockable Doors: Non-rising pins

9. Provide hinges with electrified options as scheduled in the hardware sets. Provide with number and gage of wires enough to accommodate electric function of specified hardware. Locate electric hinge at second hinge from bottom or nearest to electrified locking component. Provide mortar guard for each electrified hinge specified.

2.04 CONTINUOUS HINGES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Select

b. Best

B. Requirements:

1. Provide aluminum geared continuous hinges conforming to ANSI/BHMA A156.26, Grade 1.

DOOR HARDWARE 087100-9

2. Provide aluminum geared continuous hinges, where specified in the hardware sets, fabricated from 6063-T6 aluminum.

3. Provide split nylon bearings at each hinge knuckle for quiet, smooth, self-lubricating operation.

4. Provide hinges capable of supporting door weights up to 450 pounds, and successfully tested for 1,500,000 cycles.

5. On fire-rated doors, provide aluminum geared continuous hinges classified for use on rated doors by testing agency acceptable to authority having jurisdiction.

6. Provide aluminum geared continuous hinges with electrified option scheduled in the hardware sets. Provide with number and gage of wires enough to accommodate electric function of specified hardware.

7. Provide hinges 1 inch (25 mm) shorter in length than nominal height of door, unless otherwise noted or door details require shorter length and with symmetrical hole pattern.

2.05 ELECTRIC POWER TRANSFER

A. Manufacturers:

1. Scheduled Manufacturer and Product:

a. Von Duprin EPT-10

2. Acceptable Manufacturers and Products:

a. Securitron CEPT-10

b. Security Door Controls PTM

B. Requirements:

1. Provide power transfer with electrified options as scheduled in the hardware sets. Provide with number and gage of wires enough to accommodate electric function of specified hardware.

2. Locate electric power transfer per manufacturer's template and UL requirements, unless interference with operation of door or other hardware items.

2.06 CYLINDRICAL LOCKS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage ND series

2. Acceptable Manufacturers and Products:

a. Best Lock Co. – 9K Series

b. Corbin-Russwin CL3100 series

B. Requirements:

1. Provide cylindrical locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 1, and UL Listed for 3-hour fire doors.

2. Indicators: Where specified, provide escutcheon with lock status indicator window on top of lockset rose:

a. Escutcheon height (including rose) 6.05 inches high by 3.68 inches wide.

b. Indicator window measuring a minimum 3.52-inch by .60 inch with 1.92 square-inches of front facing viewing area and 180-degree visibility with a total of .236 square-inches of total viewable area.

DOOR HARDWARE 087100-10

c. Provide snap-in serviceable window to prevent tampering. Lock must function if indicator is compromised.

d. Provide messages color-coded with full text and symbol, as scheduled, for easy visibility.

e. Unlocked and Unoccupied message will display on white background, and Locked and Occupied message will display on red background.

3. Cylinders: Refer to ''KEYING'' article, herein.

4. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with

1/2-inch latch throw. Provide proper latch throw for UL listing at pairs.

5. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws.

6. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.

7. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.

8. Provide electrified options as scheduled in the hardware sets.

9. Lever Trim: Solid cast levers without plastic inserts and wrought roses on both sides.

a. Vandlgard: Provide levers with vandal resistant technology for use at heavy traffic or abusive applications.

b. Lever Design: LAT.

2.07 CYLINDRICAL LOCKS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage ALX series

2. Acceptable Manufacturers and Products:

a. Best Lock Co. – 7K Series

b. Corbin-Russwin CL3800 series

B. Requirements

1. Provide cylindrical locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 2, and UL Listed for 3-hour fire doors with a minimum cycle life of 1 million.

2. Cylinders: Refer to ''KEYING'' article, herein.

3. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with

1/2-inch latch throw. Provide ¾'' latch throw for UL listing at pairs.

4. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws.

5. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.

6. Provide a minimum of 5 points of lever engagement between the cassette spindle and lever shank to prevent lever sag.

7. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.

8. Plug-n-Play – Provide modular lockset allowing lock functions to be created for 7 typical functions by inserting/installing parts into the exterior of a fully assembled chassis

9. Reconfigurable Chassis - Provide modular lockset that allows the function to be reconfigured by removing external components from the chassis

10. Lever Trim: Solid cast levers and wrought roses on both sides.

a. Lever Design: Lat.

2.08 EXIT DEVICES

A. Manufacturers and Products:

DOOR HARDWARE 087100-11

1. Scheduled Manufacturer and Product:

a. Falcon 24/25 series

2. Acceptable Manufacturers and Products:

a. Sargent 19-43-GL-80 series

b. Detex Advantex series

B. Requirements:

1. Provide exit devices tested to ANSI/BHMA A156.3 Grade 1 and UL listed for Panic Exit or Fire Exit Hardware.

2. Cylinders: Refer to ''KEYING'' article, herein.

3. Provide touchpad type exit devices, fabricated of brass, bronze, stainless steel, or aluminum, plated to standard architectural finishes to match balance of door hardware.

4. Touchpad must extend a minimum of one half of door width. No plastic inserts are allowed in touchpads.

5. Provide exit devices with deadlatching feature for security and for future addition of alarm kits and/or other electrified requirements.

6. Provide flush end caps for exit devices.

7. Provide exit devices with manufacturer's approved strikes.

8. Install exit devices at height recommended by exit device manufacturer, allowable by governing building codes, and approved by Architect.

9. Mount mechanism case flush on face of doors or provide spacers to fill gaps behind devices. Where glass trim or molding projects off face of door, provide glass bead kits.

10. Provide cylinder or hex-key dogging as specified at non fire-rated openings.

11. Removable Mullions: 2 inches (51 mm) x 3 inches (76 mm) steel tube. Where scheduled as keyed removable mullion, provide type that can be removed by use of a keyed cylinder, which is self-locking when re-installed.

12. Provide factory drilled weep holes for exit devices used in full exterior application, highly corrosive areas, and where noted in hardware sets.

13. Provide electrified options as scheduled.

14. Provide exit devices with optional trim designs to match other lever and pull designs used on the project.

2.09 ELECTRONIC PROGRAMMABLE INTERCONNECTED LOCKSETS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage FE410F

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Product: Schlage FE410F interconnected electronic lockset.

1. Provide interlocked locksets conforming to ANSI A156.12 Series 5000, Grade 2 with simultaneous retraction of deadbolt and latch for single motion egress.

2. Provide locks with 2-3/4 inches (70 mm) backset, based on door detail, with 1/2-inch (13

mm) latch throw latchbolt and 1 inch (25 mm) throw deadbolt.

3. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.

4. Provide manufacturers standard T-strike, unless extended lip strike is necessary to protect trim, and deadbolt strike.

5. Rose/Escutcheon Design: Addison (ADD)

DOOR HARDWARE 087100-12

6. Lever Design: LAT

C. Requirements

1. Provide programmable electronic locksets with the following:

a. Time and Date controlled access.

b. Up to 500 user.

c. 1000 event Audit Trail report.

d. 8 time zone capability

2. Provide entry by a Key fob that supports Schlage MIFARE classic, Schlage DESFire EV1/EV3 and Schlage Mobile credentials.

3. Provide power by four (4) AA batteries (included), where if loss of battery power occurs, a 9V battery can be used to jump start the lock and provide access with an assigned credential. Battery life of 2 years in OFF-LINE MODE.

4. Coordinate with Division 01 and 281300 Access Control.

2.10 ACCESS CONTROL CREDENTIALS

A. Manufacturer:

1. Scheduled Manufacturer:

a. Schlage MIFARE DESFire EV1/EV3:

2. Acceptable Manufacturers:

a. No Substitute

B. Requirements:

1. Provide access control credentials as scheduled that are ISO 14443 compliant and GSC- IS® certified, compatible with access control readers that allow authorized entry and hold information specific to the user.

2. Provide credentials that have an ISO MIFARE microprocessor, function at 13.56 MHz, 8kbits of memory, open memory architecture, and a passive design requiring no batteries.

3. Provide credentials made of a composite material for added durability that have a read range of up to 4 inches, support up to a 40-bit format.

4. Provide credentials which, when presented to the access control reader at any angle within a minimum distance of one 1-inch, will result in an accurate reading of the card.

C. The smart credentials (“credentials”) shall communicate with a compatible reader at 13.56

MHZ, be compliant with MIFARE DESFire EV3 and be available in several physical form factors, as described below.

D. Credentials shall comply with MIFARE DESFire EV1/EV3 and meet ISO standard 14443.

1. Read range: up to 2.25”

E. Encryption:

1. Type:128-bit AES

2. The Manufacturer shall offer Owner the option to take sole possession of the encryption keys.

F. Physical type: (OPTION: SELECT ONLY THE CREDENTIAL(S) BEING SPECIFIED)

DOOR HARDWARE 087100-13

1. 8543 ISO Glossy Card

a. Single Technology 13.56 MHz

b. Dimensions: 3.37" x 2.125" x 0.033"

c. Slot punch: vertical or horizontal

2. 8643T thin keyfob

a. Single Technology 13.56 MHz

b. Dimensions: 1.77" x 1.18" x 0.11"

3. 8843T thin keyfob

a. Multi-Technology 125 kHz +13.56 MHz

b. Dimensions: 1.77" x 1.18" x 0.11"

4. All physical type credentials are engineered with PETF material for durability requirements.

G. Memory

1. Capacity: 4 KB

2. The memory shall be freely programmable.

H. The credentials shall not have an internal battery.

I. The credentials shall be available with custom artwork and laser engraving.

J. Multi-technology cards, inclusive of both 125 kHz and 13.56 MHz for backward compatibility and/or migration requirements, are available upon request.

K. Provide a CardTrax Security account for the Owner. Review language[JG1] [JG2] [JG3]

1. A security program that creates a tracking methodology to ensure specific credential property combinations are unique and never duplicated on any other cards created for the assigned account.

2. Ability to generate and manage CardTrax format (35- or 40-bit format only) credentials with unique sequential numbering embedded as per CardTrax specifications.

3. Program guarantees no duplication of cards with other users for other formats. It will be for the sole purpose of tracking numbers through the manufacturer.

4. Supports batch programming of CardTrax credentials with sequential numbering to streamline large-scale credential issuance.

2.11 OFFLINE CONTROLLER

A. Manufacturer and Product:

1. Scheduled Manufacturer and Product:

a. Schlage CTE Engage Controller

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide an offline single opening controller UL 294 listed and compatible with the Schlage Engage Application. Include a multi-technology reader kit.

DOOR HARDWARE 087100-14

2. Provide interfaces for a multi-technology credential reader, powered and dry output relays for strike, alarm, and auxiliary function, and with wireless communication capability.

3. Provide offline controller with the following power options:

a. Power Over Ethernet (POE)

1) .5A at 12 VDC for up to 500 feet.

2) 1.5A at 24 VDC for up to 500 feet.

b. 12 VDC in 2A at 12 VDC for up to 500 feet.

c. 24 VDC in 2A at 24 VDC for up to 500 feet.

4. Provide offline controller with the following communication standards:

a. Bluetooth low energy version 4.2.

b. 2.4 GHz Wi-Fi (IEEE 802.11b/g/n).

c. WPA2, WPA, WEP, 802.1x (PEAP).

d. Transport Layer Security (TLS) version 12.

e. Advanced Encryption Standard (AES) 256-bit.

5. Provide offline controller with the following signal inputs:

a. One Schlage MT11-485 or MT15-485 reader.

b. Request to Enter (REN).

c. Request to Exit (REX).

d. Remote Release – hardwired.

e. Door Position Switch (DPS).

f. Reader tamper (TAMP).

6. Provide offline controller with the following signal outputs:

a. Card Reader 0.3A at 12 VDC for up to 500 feet.

b. Locking mechanism: 2A at 30 VDC max.

c. Auxiliary: 2A at 30 VDC max.

d. Alarm: 2A at 30 VDC max.

7. Provide offline controller with the following with operating temperatures between -31 F (- 35 C) to 151 F (66 C).

8. Provide offline controller with the following on board database:

a. up to 5,000 users

b. up to 2,000 audits (FIFO)

c. up to 16 Time Zones

d. up to 32 Holiday Schedules

e. up to 16 Schedules (lock & unlock)

9. Provide offline controller with the following connectivity options:

a. Apple or Droid smart phone – Bluetooth updates to CTE.

b. Wi-Fi access point – automatic daily updates (one time per day) if connected to Wi-Fi.

C. Provide offline controller with ''No-Tour'' with MT20W enrollment reader and Schlage 1K smart credentials (13.56 MHz).

2.12 ELECTRIC STRIKES

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Von Duprin 6000 Series

2. Acceptable Manufacturers and Products:

a. Folger Adam 300 Series

DOOR HARDWARE 087100-15

b. HES 1006 Series

B. Requirements:

1. Provide electric strikes designed for use with type of locks shown at each opening.

2. Provide electric strikes UL Listed as burglary resistant that are tested to a minimum endurance test of 1,000,000 cycles.

3. Where required, provide electric strikes UL Listed for fire doors and frames.

4. Provide transformers and rectifiers for each strike as required. Verify voltage with electrical contractor.

2.13 POWER SUPPLIES

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage/Von Duprin PS900 Series

2. Acceptable Manufacturers and Products:

a. Securitron BPS series

b. Security Door Controls 600 series

B. Requirements:

1. Provide power supplies approved by manufacturer of supplied electrified hardware.

2. Provide appropriate quantity of power supplies necessary for proper operation of electrified locking components as recommended by manufacturer of electrified locking components with consideration for each electrified component using power supply, location of power supply, and approved wiring diagrams. Locate power supplies as directed by Architect.

3. Provide regulated and filtered 24 VDC power supply, and UL class 2 listed.

4. Provide power supplies with the following features:

a. 12/24 VDC Output, field selectable.

b. Class 2 Rated power limited output.

c. Universal 120-240 VAC input.

d. Low voltage DC, regulated and filtered.

e. Polarized connector for distribution boards.

f. Fused primary input.

g. AC input and DC output monitoring circuit w/LED indicators.

h. Cover mounted AC Input indication.

i. Tested and certified to meet UL294.

j. NEMA 1 enclosure.

k. Hinged cover w/lock down screws.

l. High voltage protective cover.

2.14 CYLINDERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage Everest 29

a. Corbin-Russwin Patented Keyway

DOOR HARDWARE 087100-16

b. Best Lock Patented Keyway

B. Requirements:

1. Provide cylinders/cores compliant with ANSI/BHMA A156.5; latest revision; cylinder face finished to match lockset; manufacturer’s series as indicated. Refer to “KEYING” article, herein.

2. Provide cylinders in the below-listed configuration(s), distributed throughout the Project as indicated.

a. Patented Open: cylinder with interchangeable core.

3. Patent Protection: Cylinders/cores requiring use of restricted, patented keys, patent protected.

4. Nickel silver bottom pins.

2.15 KEYING

A. Scheduled System:

1. New factory registered system:

a. Provide a factory registered keying system, complying with guidelines in

ANSI/BHMA A156.28, incorporating decisions made at keying conference.

2. Existing factory registered system:

a. Provide cylinders/cores keyed into Owner’s existing factory registered keying system.

Comply with guidelines in ANSI/BHMA A156.28, incorporating decisions made at keying conference.

B. Requirements:

1. Construction Keying:

a. Temporary Construction Cylinder Keying.

1) Provide construction cores that permit voiding construction keys without cylinder removal, furnished in accordance with the following requirements.

a) Split Key or Lost Ball Construction Keying System.

b) 3 construction control keys, and extractor tools or keys as required to void construction keying.

c) 12 construction change (day) keys.

2) Owner or Owner’s Representative will void operation of temporary construction keys.

b. Replaceable Construction Cores.

1) Provide temporary construction cores replaceable by permanent cores, furnished in accordance with the following requirements.

a) 3 construction control keys

b) 12 construction change (day) keys.

2) Owner or Owner’s Representative will replace temporary construction cores with permanent cores.

2. Permanent Keying:

a. Provide permanent cylinders/cores keyed by the manufacturer according to the following key system.

1) Master Keying system as directed by the Owner.

b. Forward bitting list and keys separately from cylinders, by means as directed by Owner. Failure to comply with forwarding requirements will be cause for replacement of cylinders/cores involved at no additional cost to Owner.

DOOR HARDWARE 087100-17

c. Provide keys with the following features:

1) Material: Nickel silver; minimum thickness of .107-inch (2.3mm)

2) Patent Protection: Keys and blanks protected by one or more utility patent(s).

3) Geographically Exclusive: Where High Security or Security cylinders/cores are indicated, provide nationwide, geographically exclusive key system complying with the following restrictions.

d. Identification:

1) Mark permanent cylinders/cores and keys with applicable blind code for identification. Do not provide blind code marks with actual key cuts.

2) Identification stamping provisions must be approved by the Architect and Owner.

3) Stamp cylinders/cores and keys with Owner’s unique key system facility code as established by the manufacturer; key symbol and embossed or stamped with “DO NOT DUPLICATE” along with the “PATENTED” or patent number to enforce the patent protection.

4) Failure to comply with stamping requirements will be cause for replacement of keys involved at no additional cost to Owner.

5) Forward permanent cylinders/cores to Owner, separately from keys, by means as directed by Owner.

e. Quantity: Furnish in the following quantities.

1) Permanent Control Keys: 3.

2) Master Keys: 6.

3) Change (Day) Keys: 3 per cylinder/core that is keyed differently

4) Key Blanks: Quantity as determined in the keying meeting.

2.16 KEY CONTROL SYSTEM

A. Manufacturers:

1. Scheduled Manufacturer:

a. Telkee

2. Acceptable Manufacturers:

a. HPC

b. Lund

B. Requirements:

1. Provide key control system, including envelopes, labels, tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet, all as recommended by system manufacturer, with capacity for 150% of number of locks required for Project.

a. Provide complete cross index system set up by hardware supplier, and place keys on markers and hooks in cabinet as determined by final key schedule.

b. Provide hinged-panel type cabinet for wall mounting.

2.17 DOOR CLOSERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. LCN 4050A series

a. Falcon SC70A series

DOOR HARDWARE 087100-18

b. Norton 7500 series

B. Requirements:

1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. ISO 9000 certify closers. Stamp units with date of manufacture code.

2. Provide door closers with fully hydraulic, full rack and pinion action with cast aluminum cylinder.

3. Closer Body: 1-1/2-inch (38 mm) diameter with 11/16-inch (17 mm) diameter heat-treated pinion journal and full complement bearings.

4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and all weather requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F.

5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards.

6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and back check.

7. Pressure Relief Valve (PRV) Technology: Not permitted.

8. Provide stick on templates, special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.

2.18 DOOR TRIM

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide push plates, push bars, pull plates, pulls, and hands-free reversible door pulls with diameter and length as scheduled.

2.19 PROTECTION PLATES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide protection plates with a minimum of 0.050 inch (1 mm) thick, beveled four edges as scheduled. Furnish with sheet metal or wood screws, finished to match plates.

DOOR HARDWARE 087100-19

2. Sizes plates 2 inches (51 mm) less width of door on single doors, pairs of doors with a mullion, and doors with edge guards. Size plates 1 inch (25 mm) less width of door on pairs without a mullion or edge guards.

3. At fire rated doors, provide protection plates over 16 inches high with UL label.

2.20 OVERHEAD STOPS AND OVERHEAD STOP/HOLDERS

A. Manufacturers:

1. Scheduled Manufacturers:

a. Glynn-Johnson

2. Acceptable Manufacturers:

a. Rixson

b. Sargent

B. Requirements:

1. Provide overhead stop at any door where conditions do not allow for a wall stop or floor stop presents tripping hazard.

2.21 DOOR STOPS AND HOLDERS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Provide door stops at each door leaf:

1. Provide wall stops wherever possible. Provide concave type where lockset has a push button of thumbturn.

2. Where a wall stop cannot be used, provide universal floor stops.

3. Where wall or floor stop cannot be used, provide overhead stop.

4. Provide roller bumper where doors open into each other and overhead stop cannot be used.

2.22 SILENCERS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

DOOR HARDWARE 087100-20

1. Provide ''push-in'' type silencers for hollow metal or wood frames.

2. Provide one silencer per 30 inches (762 mm) of height on each single frame, and two for each pair frame.

3. Omit where gasketing is specified.

2.23 THRESHOLDS, SEALS, DOOR SWEEPS, AUTOMATIC DOOR BOTTOMS, AND

GASKETING

A. Scheduled Manufacturer:

1. Zero International

B. Acceptable Manufacturers:

1. National Guard

2. Reese

3. Pemko

C. Seals and Gasketing: Provide continuous gasketing on exterior openings, to the head and jambs, forming a continuous seal between the door and the frame. Provide smoke, light, or sound gasketing on interior doors where indicated.

1. Provide self-tapping fasteners for aluminum extruded gasketing being applied to hollow metal frames.

a. Provide non-corrosive fasteners for all exterior applications.

b. Provide security fasteners where indicated.

2. Provide neoprene, EPDM, silicone, or nylon brush inserts as specified in hardware sets.

Provide non brush inserts of solid or sponge cell, as specified in hardware sets. Vinyl inserts are not allowed except where specified in hardware sets.

D. Smoke Labeled Gasketing: At all smoke labeled openings, provide smoke listed perimeter gasketing assemblies complying with NFPA 105 listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction for smoke control ratings indicated based on testing according to UL 1784.

E. Fire Listed Gasketing: Assemblies complying with NFPA 80 that are listed by a testing and inspecting agency acceptable to authorities having jurisdiction for fire ratings indicated based on testing according to UL-10C.

1. Where frame-applied intumescent seals are required by the manufacturer, provide gaskets that comply with UL10C Standard for Positive Pressure Fire Tests of Door Assemblies and UBC 7-2, Fire Tests of Door Assemblies.

F. Sound-Rated Gasketing: Provide acoustic gasketing to meet Sound Transmission Class (STC) rating required.

G. Meeting-Stile Gasketing: Provide meeting-stile gasketing that fastens to the meeting stiles forming a continuous seal when doors are closed.

H. Door Sweeps or Shoes: Apply to the bottom of the door to close the gap between the door bottom and finished floor or saddle threshold.

1. Provide solid neoprene, EPDM, silicone, or nylon brush type of seal as specified in hardware sets. Vinyl inserts are not allowed except where specified in hardware sets.

DOOR HARDWARE 087100-21

I. Automatic Door Bottoms:

1. Provide closed cell sponge, bulb neoprene. or EPDM type of seal as specified in hardware sets.

2. Door bottom to be mortised, semi mortised, or surface mount as with a minimum thickness as specified in hardware sets.

J. Rain Drips:

1. Provide overhead rain drips for out-swinging hollow metal doors that are not covered against 45 degree blowing rain. Aluminum extrusion to be a minimum of .088 inches thick and extend 2.50 inches from the face of the frame, in anodized finish to match door.

2. Door sweeps or shoes with integral rain drip must meet ADA requirements

K. Thresholds: Provide threshold units not less than 4 inches wide, formed to accommodate change in floor elevation where indicated, and fabricated to accommodate door hardware and fit door frames.

1. Threshold extrusion to be a minimum thickness as specified in hardware sets.

2.24 BALL CATCHES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide ball catches at single doors with strike to fit ANSI frame prep. If dummy levers are used in conjunction with ball catch, mount ball catch at a height as to not interfere with proper mounting and height of dummy lever.

2. Provide ball catches with full lip strike at pair doors. Mount rolling ball in top rail of each leaf per manufacturer's template.

2.25 FINISHES

A. FINISH: BHMA 626/652 (US26D); EXCEPT:

1. Aluminum Geared Continuous Hinges: BHMA 628 (US28)

2. Push Plates, Pulls, and Push Bars: BHMA 630 (US32D)

3. Protection Plates: BHMA 630 (US32D)

4. Overhead Stops and Holders: BHMA 630 (US32D)

5. Door Closers: Powder Coat to Match

6. Wall Stops: BHMA 630 (US32D)

7. Latch Protectors: BHMA 630 (US32D)

8. Weatherstripping: Clear Anodized Aluminum

9. Thresholds: Mill Finish Aluminum

DOOR HARDWARE 087100-22

PART 3 - EXECUTION

3.01 EXAMINATION

A. Prior to installation of hardware, examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance. Verify doors, frames, and walls have been properly reinforced for hardware installation.

B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.

C. Submit a list of deficiencies in writing and proceed with installation only after unsatisfactory conditions have been corrected.

3.02 INSTALLATION

A. Mount door hardware units at heights to comply with the following, unless otherwise indicated or required to comply with governing regulations.

1. Standard Steel Doors and Frames: ANSI/SDI A250.8.

2. Custom Steel Doors and Frames: HMMA 831.

3. Interior Architectural Wood Flush Doors: ANSI/WDMA I.S. 1A

4. Installation Guide for Doors and Hardware: DHI TDH-007-20

B. Install door hardware in accordance with NFPA 80, NFPA 101 and provide post-install inspection, testing as specified in section 1.03.E unless otherwise required to comply with governing regulations.

C. Install each hardware item in compliance…

This is the start of the file's text. The full file is on GovTribe.