8-08. Project Plans (15 Sheets).pdf
PDF 29 MB Posted
- Solicitation number
- Not on record
- Issued by
- Montgomery County, Pennsylvania
About this file
This document is a comprehensive project plan set consisting of 15 sheets prepared by Remington & Vernick Engineers for Upper Gwynedd Township's 2026 Liquid Fuels Road Program in Montgomery County, Pennsylvania. The project encompasses roadway rehabilitation work including mill and overlay operations on Township Line Road, Swedesford Road, and General Nash Drive, along with ADA curb ramp replacements at multiple locations. The plans include detailed mill and overlay plans for Township Line Road (2 sheets), Swedesford Road (3 sheets), and General Nash Drive (1 sheet), supplemented by three ADA site plans, two construction detail sheets, and a traffic control plan. The project design was completed in March 2026, with professional engineering oversight provided by Owen M. Hyne (PE License No. PE-080447). Contractors must verify all existing conditions and dimensions in the field prior to construction initiation and are required to obtain PA One-Call System notifications between three and ten business days before beginning excavation or demolition work.
The project plans establish comprehensive requirements for erosion and sediment control, temporary best management practices including storm inlet protection, sediment barriers, concrete washout facilities, and pumped water filter bags. Contractors bear responsibility for all maintenance, protection of traffic in accordance with PennDOT Publication 213, dewatering and groundwater infiltration management, and final site restoration. All construction specifications and details conform to current PennDOT standards including Publication 35 (Qualified Products List), Publication 408/2020 (Specifications), Publication 72M/2010 (Standards for Roadway Construction), and Publication 111 (Traffic Control Standards). The township's Public Works Department, led by Dan Ferris at 261 Township Line Road, North Wales, PA 19454, serves as the primary contact. Funding is provided through the Pennsylvania Department of Transportation Liquid Fuels Program, which supports roadway resurfacing, base repairs, and ADA accessibility improvements throughout Upper Gwynedd Township's municipal limits.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
SHEETS DESCRIPTION
1 TITLE
2 GENERAL NOTES & QUANTITIES
3 LEGEND
4 TOWNSHIP LINE ROAD MILL & OVERLAY PLAN - 1
5 TOWNSHIP LINE ROAD MILL & OVERLAY PLAN - 2
6 SWEDESFORD ROAD MILL & OVERLAY PLAN - 1
7 SWEDESFORD ROAD MILL & OVERLAY PLAN - 2
8 SWEDESFORD ROAD MILL & OVERLAY PLAN - 3
9 GENERAL NASH DRIVE MILL & OVERLAY PLAN
10 ADA SITE PLAN - 1
11 ADA SITE PLAN - 2
12 ADA SITE PLAN - 3
13 CONSTRUCTION DETAILS - 1
14 CONSTRUCTION DETAILS - 2
15 TRAFFIC CONTROL PLAN
PROJECT LOCATION MAP
2026 LIQUID FUELS ROAD PROGRAM
UPPER GWYNEDD TOWNSHIP
MONTGOMERY COUNTY, PENNSYLVANIA
MARCH 2026 1
TI
TL
E
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
K.
dw g
/9 /2
3:
:2
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
UPPER GWYNEDD TOWNSHIP SEWER
DAN FERRIS
261 TOWNSHIP LINE ROAD
NORTHWALES, PA 19454
(215) 699-5824
LIST OF UTILITIES AND
EMERGENCY CONTACT INFORMATION
PUBLIC
WORKS:
WATER:
SEWER:
ELECTRIC/
GAS:
CABLE:
CABLE:
NORTH WALES WATER AUTHORITY
200 W. WALNUT STREET
NORTH WALES, PA 19454
(215) 699-4836
UPPER GWYNEDD TWP. PUBLIC WORKS DEPARTMENT
1 PARKSIDE PLACE
NORTH WALES, PA 19454
(215) 699-7777
PECO ENERGY C/O USIC
2301 MARKET STREET
PHILADELPHIA, PA 19103
1 (800) 494-4000
COMCAST CABLE
200 CRESSON BOULEVARD
OAKS, PA 19456
(610) 650-3066
VERIZON PENNSYLVANIA LLC
1717 ARCH STREET
PHILADELPHIA, PA 19103
(215) 466-9900
TELEPHONE:
COMCAST CABLE COMMUNICATION INC.
1500 MARKET STREET
PHILADELPHIA, PA 19102
(215) 665-1700
BASE BID
N
PA ONE - CALL SYSTEM
R
-8
-2
-1
P E
S
L
N
AC
L
YLS N
P
N
OT
V A
EB FO
AI
O
U
YE
O
C LA L
D
STE
S
IG
Y
M I
C N
PROJECT LOCATION MAP
SITE
ALTERNATE BID #1
SITE
ALTERNATE BID #3
SITES
ALTERNATE BID #2
SITE
03/10/2026
G
EN
ER
AL
N O
TE
S
Q
U
AN
TI
TI
ES
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
ED
Q
.d w g
/9 /2
3:
:2
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EXISTING CONDITIONS & SURVEY NOTES
1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD. ANY ERRORS OR
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY.
EROSION & SEDIMENT CONTROL (E&S) NOTES
1. THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL TEMPORARY E&S BEST MANAGEMENT PRACTICES (BMPS) DURING THE CONSTRUCTION. TEMPORARY E&S
BMPS SHALL INCLUDE ANY DEPICTED ON THE PLANS AND THE FOLLOWING:
a. STORM INLET PROTECTION. INLET FILTER BAGS SHALL BE INSTALLED IN EACH EXISTING AND PROPOSED STORM INLET RECEIVING RUNOFF FROM THE PROJECT
AREA.
b. SEDIMENT BARRIERS. COMPOST FILTER SOCK, SILT FENCE OR OTHER SUITABLE BARRIERS SHALL BE INSTALLED ON LEVEL GRADE DOWNSTREAM FROM
DISTURBED AREAS AND STOCKPILES.
c. CONCRETE WASHOUT. FOR ANY PROJECT WHERE CONCRETE WILL BE POURED ON SITE, A SUITABLE WASHOUT FACILITY MUST BE PROVIDED.
d. PUMPED WATER FILTER BAG. A PUMPED WATER FILTER BAG SHALL BE USED TO FILTER WATER PUMPED FROM EXCAVATED AREAS (DEWATERING), SEDIMENT
STORAGE AREAS OF SEDIMENT BASINS AND SEDIMENT TRAPS.
2. E&S BMPS SHALL BE INSPECTED AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN
OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM AS
EXPECTED, REPLACEMENT BMPS OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
3. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY E&S BMPS. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT
NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION.
DEMOLITION NOTES
1. BEFORE BEGINNING ANY DEMOLITION WORK, THE CONTRACTOR SHALL INSTALL E&S BMPS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, TRANSPORTATION, AND PROPER DISPOSAL OF ALL DEMOLISHED MATERIALS. DEMOLISHED MATERIALS
MUST BE MOVED OFFSITE TO AN APPROVED FACILITY.
3. THE CONTRACTOR SHALL PERFORM DEMOLITION WORK AS NECESSARY TO FACILITATE THE PROPOSED WORK, INCLUDING ANY DEMOLITION WORK NOT SPECIFICALLY
INDICATED ON THE PLANS.
4. ALL TREES DESIGNATED FOR REMOVAL SHALL BE MARKED BY THE CONTRACTOR AND VERIFIED BY THE ENGINEER PRIOR TO REMOVAL.
5. TREE REMOVAL SHALL INCLUDE REMOVAL OF THE EXISTING TREE ALONG WITH COMPLETE STUMP REMOVAL TO A DEPTH OF ONE FOOT (1') BELOW EXISTING GRADE, PROPOSED GRADE, OR PROPOSED FEATURES, WHICHEVER IS LOWER.
GENERAL CONSTRUCTION NOTES
1. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR AND MATERIALS, INCLUDING FLAGGERS, FOR THE MAINTENANCE AND PROTECTION OF TRAFFIC (MPT)
DURING THE PROJECT IN ACCORDANCE WITH THE PROJECT PLANS AND PENNDOT PUBLICATION 213 “TEMPORARY TRAFFIC CONTROL GUIDELINES”.
2. EACH CONTRACTOR AND SUBCONTRACTOR PERFORMING EXCAVATION OR DEMOLITION WORK FOR THIS PROJECT IS REQUIRED TO SUBMIT A CONSTRUCTION
NOTIFICATION THROUGH THE PA ONE CALL SYSTEM NOT LESS THAN THREE (3) NOR MORE THAN TEN (10) BUSINESS DAYS IN ADVANCE OF BEGINNING EXCAVATION OR DEMOLITION WORK. EACH CONTRACTOR AND SUBCONTRACTOR ARE REQUIRED TO COMPLY WITH ALL PROVISIONS OF THE UNDERGROUND UTILITY LINE
PROTECTION LAW (PA ACT 287 OF 1974, AS AMMENDED).
3. THE CONTRACTOR SHALL ANTICIPATE ENCOUNTERING GROUND WATER INFILTRATION INTO EXCAVATED AREAS DURING CONSTRUCTION. ALL COSTS ASSOCIATED WITH SIZING AND PROVIDING TEMPORARY BYPASS PUMPING AND/OR DEWATERING SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
4. ALL FILL SHALL BE PLACED IN EIGHT INCH (8”) LAYERS AND THOROUGHLY COMPACTED TO THE SATISFACTION OF THE ENGINEER. IF BORROW FILL IS REQUIRED, IT
SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER.
5. THE CONTRACTOR SHALL EXERCISE PARTICULAR CARE WHEN CONSTRUCTING OR RESURFACING PAVEMENT, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE FLOWING STORMWATER. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY THE CONTRACTOR AT NO COST TO THE OWNER.
6. ALL PEDESTRIAN ACCESS TO SIDEWALKS AND STREETS, INCLUDING CROSSWALKS, CURB RAMPS, STREET FURNISHINGS, PEDESTRIAN SIGNALS, PARKING AND OTHER COMPONENTS OF PEDESTRIAN ACCESS PROPOSED IN BUILDINGS, SITES OR THE RIGHT-OF-WAY ARE TO BE IN ACCORDANCE WITH AMERICANS WITH DISABILITIES ACT (ADA) & ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES AND THE CURRENT PUBLIC RIGHTS-OF-WAY GUIDELINES PROPOSED BY THE ARCHITECTURAL
AND TRANSPORTATION BARRIERS COMPLIANCE BOARD (ACCESS BOARD).
7. ALL PLANTING LOCATIONS SHOWN ON THE PLANS ARE APPROXIMATE. FINAL LOCATIONS FOR ALL PLANTINGS SHALL BE MARKED BY THE CONTRACTOR AND VERIFIED
BY THE ENGINEER PRIOR TO PLANTING.
8. ALL CONSTRUCTION SPECIFICATIONS AND DETAILS NOT SHOWN SHALL BE IN ACCORDANCE WITH PENNDOT STANDARDS AS DETAILED IN THE LATEST REVISIONS OF
THE FOLLOWING:
a. PUBLICATION 35 (BULLETIN 15) “QUALIFIED PRODUCTS LIST FOR CONSTRUCTION”;
b. PUBLICATION 408/2020 ”SPECIFICATIONS”;
c. PUBLICATION 72M/2010 “STANDARDS FOR ROADWAY CONSTRUCTION”;
d. PUBLICATION 111 “TRAFFIC CONTROL - PAVEMENT MARKINGS AND SIGNING STANDARDS”;
e. PUBLICATION 213 “TEMPORARY TRAFFIC CONTROL GUIDELINES”.
INCLUDING ALL APPLICABLE BASELINE DOCUMENT CHANGES AND APPENDICES. THESE CONSTRUCTION SPECIFICATIONS AND DETAILS MAY BE PURCHASED THROUGH
THE PENNDOT SALES STORE AT:
P.O BOX 2028
HARRISBURG, PA 17105-2028
(TELEPHONE: 1-717-787-6746)
UTILITY NOTES
1. LOCATION OF EXISTING UTILITIES ARE APPROXIMATE AND MUST BE VERIFIED IN THE FIELD PRIOR TO THE START OF CONSTRUCTION.
2. UNLESS NOTED OTHERWISE, THE APPROXIMATE DEPTH OF ALL EXISTING WATER MAIN IS ± 4 FEET.
3. UNLESS NOTED OTHERWISE, APPROXIMATE DEPTH OF ALL EXISTING GAS MAIN IS ± 3 FEET.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF THE UNDERGROUND AND SURFACE UTILITIES AND STRUCTURES AT OR
ADJACENT TO THE SITE OF CONSTRUCTION AND IT SHALL BE AT THEIR OWN EXPENSE TO REPAIR OR REPLACE ANYTHING THAT THEY DAMAGE.
5. THE CONTRACTOR SHALL USE PENNDOT NO. 2A COARSE AGGREGATE FOR BACKFILL BENEATH ANY STRUCTURES OR PAVEMENT AREAS, INCLUDING GRAVEL SURFACES.
6. THE CONTRACTOR MAY USE EXCAVATED MATERIALS FOR BACKFILL IN UNPAVED AREAS, UNLESS OTHERWISE DIRECTED BY THE ENGINEER.
CONCRETE NOTES
1. EXPANSION JOINTS (A.K.A. ISOLATION JOINTS) SHALL BE INSTALLED IN CONCRETE CURB AND SIDEWALK AREAS EVERY FORTY FEET (40') OR WHEREVER CONCRETE
CURB OR SIDEWALK AREAS ADJOIN STRUCTURES (E.G. CURBS, BUILDINGS, UTILITY POLES, EXISTING SIDEWALKS, ETC.), AND AT HE END OF EACH DAYS CONCRETE
PLACEMENT.
2. SEPARATE PAYMENT WILL NOT BE MADE FOR PROVIDING EXPANSION JOINT MATERIAL FOR ALL CONCRETE WORK, BUT THE COST SHALL BE INCLUDED IN THE
VARIOUS ITEMS OF THE PROPOSAL.
3. CONTRACTION JOINTS (A.K.A. CONTROL JOINTS) SHALL BE INSTALLED IN ALL CONCRETE CURB EVERY TEN FEET (10') AND IN SIDEWALK AREAS EVERY EIGHT FEET (8') OR THE WIDTH OF THE SIDEWALK, WHICHEVER IS LESS, EACH WAY. CONTRACTION JOINTS SHALL BE SAWCUT OR HAND GROOVED INTO CONCRETE WITHIN 12 HOURS OF
THE CONCRETE HARDENING.
4. REINFORCEMENT SHALL BE SECURED IN THE PROPER LOCATION IN THE FORMS WITH TIE WIRE OR OTHER BAR SUPPORT SYSTEM TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. STEEL REINFORCEMENT IN CONCRETE SHALL HAVE A MINIMUM COVER OF THREE INCHES (3”) WHEN CAST AGAINST THE EARTH AND TWO
INCHES (2”) WHEN CAST IN REMOVABLE FORMS AND EXPOSED TO THE EARTH OR WEATHER.
5. NO ADDITIONAL WATER SHALL BE ADDED TO CONCRETE.
6. ON FORMED CONCRETE SURFACES, THE CONTRACTOR SHALL CURE FINISHED CONCRETE BY APPLYING TWO (2) COATS OF A WHITE PIGMENTED CURING COMPOUND
(ASTM C 309, TYPE 2). THE FIRST COAT SHALL BE APPLIED IMMEDIATLY AFTER STRIPPING THE FORMS. THE SECOND COAT SHALL BE APPLIED IMMEDIATELY AFTER THE
FIRST COAT HAS SET.
7. COLD WEATHER CONCRETE. IN ACCORDANCE WITH ACI 306R-16, THE CONTRACTOR SHALL PROVIDE ADDITIONAL PROTECTION WHEN PLACING CONCRETE DURING
COLD WEATHER, DEFINED AS 40°F OR BELOW:
a. THE CONTRACTOR SHALL ARANGE FOR COLD WEATHER CONCRETE EQUIPMENT AND MATERIALS SUCH AS TARPING OR BLANKETS TO BE AT THE PROJECT SITE
BEFORE COLD WEATHER IS LIKELY TO OCCUR.
b. FROZEN SUBGRADE MUST BE THAWED PRIOR TO THE PLACEMENT OF CONCRETE.
c. CURE AND PROTECT CONCRETE AGAINST DAMAGE FROM FREEZING FOR A MINIMUM PERIOD OF THREE (3) DAYS, UNLESS OTHERWISE SPECIFIED. THE
PROTECTION PERIOD MAY BE REDUCED TO TWO (2) DAYS IF ONE OR MORE OF THE FOLLOWING ARE IMPLEMENTED: (1) TYPE 3 PORTLAND CEMENT MEETING REQUIREMENTS OF ASTM C 150; (2) A STRENGTH ACCELERATING ADMIXTURE MEETING THE REQUIREMENTS OF ASTM C 494; OR (3) 100 LB/CY OF ADDITIONAL
CEMENT.
PAVEMENT NOTES
1. AT THE END OF EACH WORKDAY, THE CONTRACTOR SHALL BACKFILL ANY EXCAVATED AREAS WITHIN ROADWAYS, INSTALL TEMPORARY PAVEMENT RESTORATIONS
AND REOPEN ROADWAYS FOR VEHICLE TRAFFIC. THE USE OF COLD PATCH MATERIAL OR STEEL PLATES (SECURE PLATES AS NECESSARY) ON LOCAL STREETS REQUIRES
PRIOR AUTHORIZATION BY THE ENGINEER AND IS PROHIBITED ON STATE HIGHWAYS.
2. THE CONTRACTOR SHALL REMOVE ANY TEMPORARY PAVEMENT RESTORATIONS AND INSTALL PERMANENT PAVEMENT RESTORATIONS FOR ALL EXCAVATED AREAS
PRIOR TO BEGINNING SAWCUTTING OR MILLING FOR PAVEMENT RESURFACING WORK.
3. THE CONTRACTOR SHALL VERIFY THE LIMITS OF PAVEMENT RESURFACING OR RECONSTRUCTION WORK WITH THE ENGINEER PRIOR BEGINNING TO ASSOCIATED
SAWCUTTING OR MILLING.
4. THE CONTRACTOR SHALL SAWCUT CLEAN JOINTS THROUGH EXISTING ASPHALT PAVEMENT TO FACILIATE NEW BUTT JOINTS. THE CONTRACTOR SHALL MILL AN EIGHTEEN INCHES (18”) WIDTH OF THE EXISTING PAVEMENT BEYOND THE JOINT TO PROVIDE AN OVERLAP OF NEW SURFACE COURSE ASPHALT PAVEMENT OVER
EXISTING ASPHALT PAVEMENT.
5. AFTER MILLING ASPHALT PAVEMENT SURFACES, THE CONTRACTOR SHALL PROVIDE A FULLY LOADED TRI-AXLE DUMP TRUCK AND PERFORM A PROOF ROLL OF MILLED
SURFACES WITH THE ENGINEER TO DETERMINE AREAS FOR BASE REPAIR. BASE REPAIRS SHALL BE PERFORMED PRIOR TO INSTALLING SCRATCH, LEVELING OR
WEARING COURSES.
6. THE CONTRACTOR SHALL ADJUST ALL EXISTING MANHOLES, UTILITY COVERS AND VALVE BOXES TO AN ELEVATION FIVE-EIGHTHS OF AN INCH (5/8”) BELOW THE
PROPOSED PAVEMENT SURFACE.
7. THE CONTRACTOR SHALL PAINT EXISTING VERTICAL SURFACES OF CURBS, STRUCTURES, GUTTERS, AND PAVEMENTS THAT WILL BE IN CONTACT WITH ASPHALT MIXTURES WITH A UNIFORM COATING OF EITHER EMULSIFIED ASPHALT, CONSISTING OF PENNDOT MATERIAL CLASS TACK OR HOT ASPHALT BINDER OF THE CLASS
AND TYPE AS SPECIFIED IN SECTION 460 OF PENNDOT PUBLICATION 408.
CONTRACT NOTES
1. THE CONTRACTOR SHALL MAKE A PRE-CONSTRUCTION VIDEO OF THE PROJECT AREA BEFORE BEGINNING ANY CONSTRUCTION ACTIVITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL EXISTING CONCRETE CURB AND SIDEWALK AREAS NOT SHOWN TO BE REMOVED OR REPLACED. THE
CONTRACTOR WILL BE RESPONSIBLE FOR COMPLETE REMOVAL AND REPLACEMENT OF ANY DAMAGED CURB OR SIDEWALK NOT DOCUMENTED PRIOR TO THE START
OF CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
3. THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH OTHER PRIME CONTRACTORS FOR THIS PROJECT, IF APPLICABLE. IN ADDITION, THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH PRIME CONTRACTORS ON OTHER PROJECTS UNDER CONSTRUCTION NEAR THE PROJECT AREA. ANY COORDINATION ISSUES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. THERE WILL NOT BE ANY SEPARATE PAYMENT FOR THIS COORDINATION, BUT THE COST SHOULD BE
INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
4. RECONSTRUCTION OF EXISTING MANHOLES AND INLETS, INCLUDING CONCRETE CAPS AND OTHER NECESSARY MODIFICATIONS TO ACCOMMODATE NEW INLET CONSTRUCTION, SHALL BE INCLUDED IN THE UNIT PRICE BID FOR INLETS AND MANHOLES OF THE VARIOUS KINDS.
5. SEPARATE PAYMENT WILL NOT BE MADE FOR SAWCUTTING OF ANY KIND, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
6. SEPARATE PAYMENT WILL NOT BE MADE FOR STEEL TREE ROOT PROTECTION PLATES, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
7. SEPARATE PAYMENT WILL NOT BE MADE FOR THE REMOVAL, TEMPORARY STORAGE AND REINSTALLATION OF EXISTING SIGNAGE ALONG THE PROJECT AREA, BUT THE
COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
8. SEPARATE PAYMENT WILL NOT BE MADE FOR THE EXCAVATION OF ROCK.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TRANSPORTATION AND PROPER DISPOSAL OF ALL UNUSED MATERIAL EXCAVATED FROM THE PROJECT SITE. PROPER
DISPOSAL SHALL BE IN ACCORDANCE WITH PA DEP REQUIREMENTS.
10. CONTRACTOR SHALL RESTORE ALL EXISTING FEATURES DISTURBED DURING CONSTRUCTION (I.E. MAILBOXES, IRRIGATION SYSTEMS, LANDSCAPING, ETC.). ALL COSTS
SHALL BE INCLUDED IN THE PRICE BID FOR SITE CLEARING.
11. THE CONTRACTOR SHALL ANTICIPATE GROUND WATER INFILTRATION INTO ALL OF THE COMBINED SEWER/STORM SEWER PIPES, INLETS AND MANHOLES WHEN
PERFORMING THE VARIOUS TASKS ASSOCIATED WITH THIS PROJECT. ALL COSTS ASSOCIATED WITH THE TEMPORARY BYPASS PUMPING AND OR DEWATERING SHALL
BE INCLUDED IN THE VARIOUS ITEMS IN THE PROPOSAL.
12. SEPARATE PAYMENT WILL NOT BE MADE FOR EXCAVATION, DEWATERING, FITTINGS, PIPE BEDDING, SHEETING, BRACING, SHORING, INLET CONNECTIONS, TRAPS, AND SUITABLE BACKFILL MATERIAL INVOLVED IN ALL PIPE AND ASSOCIATED STRUCTURES REMOVAL, RECONSTRUCTION AND INSTALLATION, BUT THE COST SHALL BE
INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL REGARDLESS OF DEPTH.
SITE SAFETY, CLEANLINESS & RESTORATION NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY ON THE PROJECT SITE AND FOR FOLLOWING ALL OSHA AND LOCAL SAFETY STANDARDS.
2. THE CONTRACTOR SHALL ENSURE THAT THE SITE IS SECURE AT THE END OF EACH WORKDAY. ALL EQUIPMENT AND MATERIALS SHOULD BE STORED NEATLY AND
SECURELY. EXCAVATED AREAS SHALL BE BACKFILLED OR SECURED TO PREVENT ANY FALL HAZARD.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING PAVED SURFACES, INCLUDING SIDEWALKS, FREE AND CLEAR OF SEDIMENT AND IN A BROOM SWEPT
CONDITION WHEN OPEN TO PUBLIC USE. AT A MINIMUM, THE CONTRACTOR SHALL CLEAN PAVED SURFACES AT THE END OF EACH WORKDAY AND WHEN DIRECTED
BY THE ENGINEER.
4. THE ALL VEGETATED AREAS DISTRIBUTED DURING CONSTRUCTION SHALL BE TOPSOILED, SEEDED, FERTILIZED AND COVERED WITH STRAW MULCH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING AND/OR RE-SEEDING AS NECESSARY TO ENSURE VEGETATIVE STABILIZATION.
5. ALL PAVED AND CONCRETE AREAS EXCAVATED OR DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITION AT LEAST EQUAL TO THAT WHICH
EXISTED PRIOR TO THE START OF CONSTRUCTION.
6. PRIOR TO FINAL PAYMENT, THE CONTRACTOR SHALL PERFORM FINAL CLEANING. FINAL CLEANING SHALL INCLUDE REMOVAL AND PROPER DISPOSAL OF ALL EXCESS
CONSTRUCTION MATERIALS AND DEBRIS AS WELL AS CLEANING ALL PAVED SURFACES.
IRRIGATION PIPE
WATER SERVICE
COMMUNICATIONS SERVICE
TELEPHONE SERVICE
FIBER OPTIC SERVICE
ELECTRIC SERVICE
SANITARY SEWER PIPE $12"
SANITARY SEWER PIPE [12"
GAS SERVICE
STORM SEWER PIPE $12"
STORM SEWER PIPE [12"
SANITARY FORCE MAIN PIPE
OVERHEAD WIRE
WATER SHUT-OFF
WATER METER
WATER VALVE
WATER HYDRANT
WELL
YARD HYDRANT
METER PIT
GAS SHUT-OFF
GAS METER
GAS VALVE
GAS LINE MARKER
CLEANOUT
SEWER VENT
IRRIGATION CONTROL VALVE
IRRIGATION BOX
IRRIGATION CONTROL BOX
SPRINKLER HEAD
COMMUNICATIONS PEDESTAL
COMMUNICATIONS LINE MARKER
TELEPHONE PEDESTAL
TELEPHONE LINE MARKER
ELEC. BOX
ELEC. METER
ELEC. TRANSFORMER PAD
ELEC. VAULT
ELEC. LINE MARKER
MANHOLES
UTILITY POLE
GUY ANCHOR
ELEC. OUTLET
AREA DRAIN
LIGHTS
CONCRETE MONUMENT
PK / MAG NAIL / DRILL HOLE / SPIKE
STAKE
HUB
PIN W/ CAP
IRON PIPE
CROSS CUT
DRILL HOLE W/ WINGS
DISK
STONE
REBAR
BASELINE
CENTERLINE
EASEMENT
RIGHT-OF-WAY
BORING LOCATION
MONITORING WELL LOCATION
TEST PIT LOCATION
FRESHWATER WETLAND FLAG
FRESHWATER WETLAND LINE
EDGE OF WATER
STREAM CENTERLINE
DECIDUOUS TREE
SHRUBS / BUSH
EVERGREENS
STUMP
WOODS / TREE LINE
CROWS FOOT
IRON PIN
PROPERTY BOUNDARY
RAILROAD TRACKS
ADJACENT PROPERTY BOUNDARY
STATE BOUNDARY
MUNICIPAL / COUNTY BOUNDARY
FRESHWATER WETLAND BUFFER
WIRE FENCE
SPLIT RAIL FENCE
WOOD / VINYL FENCE
CHAIN-LINK FENCE
TOP OF BANK / DITCH
BOTTOM OF BANK / DITCH
FLOW LINE / SWALE
CONTOUR (MAJOR)
CONTOUR (MINOR)
TIME OF CONCENTRATION
ROADWAY GRADE
DRAINAGE FLOW
EDGE OF PAVEMENT
CURB
PAVEMENT / CONC. / SIDEWALK
LIMIT OF EXCAVATION
GUIDE RAIL
BOLLARD
MAILBOX
SIGNS
FLAG POLE
BENCH
PILE
TRAFFIC CONTROL BOX
TRAFFIC LIGHT
DEPT. OF TRANSPORTATION MANHOLE
STATE HIGHWAY DEPARTMENT
TYPICAL NORTH ARROW
BENCHMARK LOCATION
DETECTABLE WARNING SURFACE
TYPICAL STRIPING
ADA STRIPING
CALL BOX
OIL FILL
UNDERGROUND STORAGE TANK LID
RISER PIPE
UNKNOWN VALVE
VENT
VENT PIPE
SPOT GRADE
AERIAL TARGET
RAILROAD CROSSING BEACON
RAISED PAVEMENT MARKER
GRASS/SOD
APR. APRON EL. ELEVATION PERF. PERFORATED SWL SINGLE WHITE LINE
ASB ASBESTOS CEMENT PIPE EX. EXISTING PC POINT OF CURVATURE SYL SINGLE YELLOW LINE
AFF ABOVE FINISHED FLOOR FFE FINISH FLOOR ELEVATION PI POINT OF INFLECTION TBA TO BE ABANDONED
ASB ASBESTOS FT FEET PT POINT OF TANGENCY TBR TO BE REMOVED
AL ALUMINUM E.B.,W.B,
N.B.,S.B.
EASTBOUND, WESTBOUND,
NORTHBOUND, SOUTHBOUND PSI POUNDS PER SQUARE INCH TC TOP OF CURB
BL BASELINE GL GUTTER LINE PK PARKER KAYLON MASONRY NAIL TEL TELEPHONE
BM BENCH MARK GR GRATE PROP. PROPOSED TEMP. TEMPORARY
BIT. BITUMINOUS GALV. GALVANIZED PVC POLYVINYL CHLORIDE PIPE TYP. TYPICAL
BLDG. BUILDING HW HEADWALL PVC POINT OF VERTICAL
CURVATURE UD UNDERDRAIN
BGS BELOW GROUND SURFACE HDPE HIGH DENSITY POLYETHYLENE PIPE PVI POINT OF VERTICAL
INTERSECTION UP UTILITY POLE
CL CENTERLINE INV. INVERT PVT POINT OF VERTICAL TANGENCY V VOLTS
CIP CAST IRON PIPE IP IRON PIN R RADIUS VAR. VARIES
CONC. CONCRETE IN INCHES RCP REINFORCED CONCRETE PIPE WM WATER METER
CMP CORRUGATED METAL PIPE JB JUNCTION BOX RMC RIGID METALLIC CONDUIT
CULV. CULVERT LSA LANDSCAPED AREA R.O.W. RIGHT OF WAY
CS CARBON STEEL LF LINEAR FEET R.R. RAILROAD
CF CUBIC FEET LST LANDSCAPE TIE RTE. ROUTE
CY CUBIC YARDS LOM LIMIT OF MILLING SAN. SANITARY
CMU CONCRETE MASONRY UNIT LOP LIMIT OF PAVING SS STAINLESS STEEL
D.C. DEPRESSED CURB MB MAILBOX SWK. SIDEWALK
DH DRILL HOLE MAX. MAXIMUM SHD STATE HIGHWAY DEPARTMENT
DIA. DIAMETER MIN. MINIMUM SHLD. SHOULDER
DIP DUCTILE IRON PIPE MH MANHOLE STY. STORY
DWY DRIVEWAY NO. NUMBER STA. STATION
DYL DOUBLE YELLOW LINE N.T.S. NOT TO SCALE
P PIPE
HEADWALL W/ WINGS
HEADWALL
INLET TYPE M
INLET TYPE C
INLET TYPE DOUBLE M
LE
G
EN
D
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
ED
Q
.d w g
/9 /2
3:
:3
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
TO
W
N
SH
IP
L
IN
E
R O
AD
M
IL
L
O
VE
R
LA
Y
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:4
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 30' 60'
1 INCH =
GRAPHIC SCALE
30 FT.
90'
TO
W
N
SH
IP
L
IN
E
R O
AD
M
IL
L
O
VE
R
LA
Y
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:5
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 30' 60'
1 INCH =
GRAPHIC SCALE
30 FT.
SW
ED
ES
FO
R D
R O
AD
M
IL
L
O
VE
R
LA
Y
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:1
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 30' 60'
1 INCH =
GRAPHIC SCALE
30 FT.
ED
ES
FO
R D
R O
AD
M
IL
L
O
VE
R
LA
Y
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:2
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 30' 60'
1 INCH =
GRAPHIC SCALE
30 FT.
ED
ES
FO
R D
R O
AD
M
IL
L
O
VE
R
LA
Y
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:3
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 30' 60'
1 INCH =
GRAPHIC SCALE
30 FT.
G
EN
ER
AL
N
AS
H D
R
IV
E M
IL
L
O
VE
R
LA
Y
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:4
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 40' 80'
1 INCH =
GRAPHIC SCALE
40 FT.
120'
AD
A
SI
TE
P
LA
N
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:4
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 20' 40'
1 INCH =
GRAPHIC SCALE
20 FT.
60'
A
SI
TE
P
LA
N
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:5
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 20' 40'
1 INCH =
GRAPHIC SCALE
20 FT.
A
SI
TE
P
LA
N
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
C .d w g
/9
/2
3:
:4
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
0 20' 40'
1 INCH =
GRAPHIC SCALE
20 FT.
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
D
ET
.d w g
/9 /2
3:
:5
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
D
ET
.d w g
/9 /2
3:
:5
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
TR
AF
FI
C
C O
N
TR
O L
PL
AN
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JMB DF OH
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_M on tg om er y\
_U pp er
G w yn ed d\ T\
T0
-2
U
G T
R oa d Pr og ra m \0
2_ D es ig n th ru C on tra ct s\
_C
AD
D
\D W
G \P
A4
4T
3-
D
ET
.d w g
/9 /2
3:
:5
PM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
of 02-26-2026
PA461504T003
AS NOTED
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
U
PP
ER
G
W
YN
ED
D
T O
W N
SH
IP
M O
N
TG
O M
ER
Y
C O
U N
TY
PE
N N
SY
LV
AN
IA
L
IQ
U
ID
F U
EL
S
R O
AD
P
R O
G R
AM
PROFESSIONAL ENGINEER LIC. No. PE-080447
OWEN M. HYNE
DATE:
REMINGTON
& VERNICK
ENGINEERS
(610) 940-1050, FAX (610) 940-1161
Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406
WEB ADDRESS : RVE.COM
| Sheets and Views |
| 1 TITLE |
| 2 GENERAL NOTES & QUANTITIES |
| 3 LEGEND |
| 4 TOWNSHIP LINE ROAD MILL & OVERLAY PLAN - 1 |
| 5 TOWNSHIP LINE ROAD MILL & OVERLAY PLAN - 2 |
| 6 SWEDESFORD ROAD MILL & OVERLAY PLAN - 1 |
| 7 SWEDESFORD ROAD MILL & OVERLAY PLAN - 2 |
| 8 SWEDESFORD ROAD MILL & OVERLAY PLAN - 3 |
| 9 GENERAL NASH DRIVE MILL & OVERLAY PLAN |
| 10 ADA SITE PLAN - 1 |
| 11 ADA SITE PLAN - 2 |
| 12 ADA SITE PLAN - 3 |
| 13 CONSTRUCTION DETAILS - 1 |
| 14 CONSTRUCTION DETAILS - 2 |
| 15 TRAFFIC CONTROL PLAN |
File details come from the government source that posted it. Updated .