This is a Site Exploration and Geotechnical Engineering Report for a proposed Tracker Mounted Array Solar system installation at Rosebud IHS Hospital in Rosebud, South Dakota, prepared by Twin Rivers Testing & Environmental, LLC, dated October 20, 2014.
The project involves installing twelve Tracker Mounted Array Solar units in an area measuring 154 feet by 219 feet northwest of the IHS Hospital. The site subsurface exploration identified Sandy Lean Clay, Clayey Sand, and Poorly Graded Sand with Clay materials. The solar panels will be supported by helical pile foundation systems installed to a depth of ten feet below existing grade, with site grading requiring approximately one foot of cut/fill. The geotechnical engineer recommends lateral bearing pressures of 180 PSF for Sandy Lean Clay (with notation that this material should be neglected due to frost action) and 250 PSF for Clayey Sand and Poorly Graded Sand. No groundwater was encountered during drilling on August 27, 2014, though the report notes that groundwater levels may fluctuate seasonally. The field investigation consisted of two soil test borings drilled to 15 feet below ground surface using standard penetration testing and laboratory analysis including natural water content, unconfined compression, sieve wash, and Atterberg limits tests.
The report provides detailed site preparation, fill placement, excavation, utility trenching, seismic design, and drainage recommendations for construction. Site Class "D" is recommended for seismic design calculations per the 2003 International Building Code. All fill materials require geotechnical engineer approval and testing prior to placement, with specified compaction standards and moisture content requirements. The contractor bears sole responsibility for designing and constructing stable temporary excavations in accordance with OSHA regulations (29 CFR Part 1926). The report emphasizes that boring logs depict subsurface conditions only at specific drilling locations and variations should be expected between locations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A03 Add Geotech Report from 300 fT Away RLSC.pdf | ||
| A02 Pump Specs RLSC.pdf | ||
| A01 Add Attachment RLSC.pdf | ||
| J03a Plans RLSC.pdf | ||
| J06 WH-347 Payrolls Exp 31Jan2028.pdf | ||
| J05 Self Performed Calculation Sheet.docx | DOCX document | |
| Optional Company Specialized Experience Form.pdf | ||
| J04 Wage Det SD20260018 18May2026.pdf | ||
| J07 Release of Claims.docx | DOCX document | |
| J02 Block 17 Support Schedule RLSC.docx | DOCX document | |
| B01 RFP RLSC 75H70126R00030.pdf | ||
| J01 SOW Rosebud Lift Station Construction.docx | DOCX document | |
| Optional Past Performance Questionnaire.docx | DOCX document | |
| J03 Tech Specs RLSC.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .