Sheet A3 Plan Details.pdf
PDF 266 KB Posted
- Attached to
- Roof Replacement at Crow Agency, MT
- Solicitation number
- 75H701-20-R-00038
About this file
This document contains details for a federal roof replacement contract opportunity and related project documents. The Indian Health Service is soliciting proposals for roof replacement services at the Crow Service Unit in Crow Agency, Montana under solicitation number 75H701-20-R-00038. The project has a magnitude between $500,000 and $1 million, has a NAICS code of 238160 for roofing contractors, and is set aside for small businesses with a size standard of $16.5 million in annual receipts. Proposals are due by 2:00 PM MDT on June 29, 2020. The document also includes construction drawings and details for the roof replacement work. A mandatory site visit will be held and all questions must be submitted in writing by noon on June 15, 2020.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TERO WPA - Amended (5-10).pdf | ||
| Parapet detail.jpg | JPG image | |
| TERO Compliance Plan.docx | DOCX document | |
| TERO WPA Agreement with Employer.docx | DOCX document | |
| Sheet A4 Expansion Joint-Parapet to Parapet.pdf | ||
| Amendment 00002_75H701-20-R-00038.docx | DOCX document | |
| TERO Certification App.pdf | ||
| Materials schedule.jpg | JPG image | |
| Amendment 0001_75H701-20-R-00038.docx | DOCX document | |
| Solicitation - 75H701-20-R-00038.docx | DOCX document | |
| Section J_Attachment 2 18CR203H6-dwgs-20191029.pdf | ||
| Section J_Attachment 3 WD_MT20200056_02212020.pdf | ||
| Section J_Attachment 1 18CR203H6-Crow-NC Roof - Specs.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 1/2" METAL ROOF DECK
5/8" TYPE X GYPSUM BOARD
6 MIL VAPOR BARRIER
1 1/2" POLYISOCYANURATE
ROOF INSULATION
TAPERED ROOF INSULATION
THICKNESS VARIES
1/2" RECOVERY BOARD
ROOF MEMBRANE
MECHANICALLY FASTENED
REMOVE AND REPLACE
NOTE: REMOVE AND REPLACE RECOVERY BOARD AND INSULATION IF DAMAGED
AND DIRECTED TO REPLACE BY ENGINEER.
REMOVE & REPLACE
EXISTING FASCIA
SINGLE PLY MEMBRANE
SET IN BONDING ADHESIVE
LAP OVER TOP OF PARAPET
CONTINUOUS SEALANT
BETWENN WALL & FASCIA
EXTEND ROOF MEMBRANE
MIN. 6" ONTO PARAPET
FASTEN WITH TERMINATION BAR
EXTEND PARAPET MEMBRANE
MIN 6" ONTO ROOF
HEAT WELD AND CAULK SEAM
SEALANT
METAL TERMINATION BAR
MEMBRANE FLASHING
IN BONDING ADHESIVE
METAL TERMINATION BAR
HOT AIR WELD
SEAM CAULK
INSTALL REGLET COUNTERFLASHING
EXTEND A MINIMUM 2" BELOW
TERMINATION BAR
APPROX. 1" SAWCUT IN MORTAR
FOR REGLET INSTALLATION
SEAL CUT TO PRECLUDE WATER
12" MIN
EXTEND ROOF MEMBRANE
OVER MEMBRANE FLASHING
PLATE & FASTENER
HOT AIR WELD
& SEAM CAULK
MEMBRANE FLASHING SET IN BONDING ADHESIVE
EXTEND INTO DRAIN BOOT BELOW CLAMPING RING
USE SEALANT BELOW FLASHING IN DRAIN BOOT
DECK CLAMP
ROOF DRAIN
SINGLE PLY MEMBRANE
SET IN BONDING ADHESIVE
LAP OVER TOP OF CURB
EXTEND ROOF MEMBRANE
MIN. 6" ONTO CURB
FASTEN WITH TERMINATION BAR
EXTEND CURB MEMBRANE
MIN 6" ONTO ROOF
HEAT WELD AND CAULK SEAM
REMOVE AND REINSTALL
CURB MOUNTED EQUIPMENT
WATER CUT-OFF MASTIC
STAINLESS STEEL
CLAMPING RING
PREMOLDED PIPE SEAL
ROOF MEMBRANE
LAP SEALANT
SEAM SEALANT
FASTEN MEMBRANE W/
TERMINATION BAR
REMOVE AND REPLACE
EXISTING FASCIA
EXTEND MEMBRANE FLASHING
BELOW FASCIA
ADHERE TO SUBSTRATE WITH
BONDING ADHESIVE
SKYLIGHT
AIR WELD &
SEAM CAULK
SCALE 1" = 1'-0"
TYPICAL ROOF CONSTRUCTION
SCALE 1 1/2" = 1'-0"
ROOF TO PARAPET
SCALE 1 1/2" = 1'-0"
ROOF TO WALL
SCALE 1 1/2" = 1'-0"
ROOF DRAIN
SCALE 1 1/2" = 1'-0"
MECHANICAL EQUIPMENT CURBS
SCALE 1 1/2" = 1'-0"
VENTS & PIPES
SCALE 1 1/2" = 1'-0"
SKYLIGHT
1A3 2A3
3A3
4A3
5A3
6A3
7A3