About this file
This is a Work Write-Up document prepared by the City of Jackson Community Development Department for electrical system repairs at 717 Elmwood Avenue, Jackson, Michigan. The project involves one electrical-to-code work item (Specification ID: 80.00000) requiring comprehensive updates to bring the residential structure into compliance with Housing Code and Electrical Regulations, as well as the 2023 Michigan Residential Code (MRC) and 2015 MRC standards. The scope includes installation of a new 200-amp service panel (duplex) with disconnect, meter base, riser, service wire, grounding and bonding; hardwired smoke and carbon monoxide detectors with interconnection capability; new dedicated circuits for furnace and water heater; removal of unused basement wiring; installation of four basement service lights with GFCI protection; two dedicated 20-amp kitchen circuits with GFCI protection; one dedicated 20-amp bathroom circuit with GFCI protection and lights; removal and replacement of knob and tube wiring; and exterior lighting and tamper-resistant GFCI receptacles at front and rear doors. The document was prepared on June 23, 2026, and is dated as Exhibit 1. The property owner is John O'Dowd located at 3418 Caroline Drive, Jackson, Michigan 49203.
The work write-up includes a fixture allowance of $500.00 incorporated into the bid price, with the electrical contractor responsible for all wall and ceiling repairs resulting from wire installation, ensuring repairs are smooth, sanded, and ready for paint. A permit is required for this project. The contractor must obtain a change order from the Rehabilitation Specialist prior to installation of wiremold or similar exposed wiring in living areas, and the contractor is responsible for daily cleanup and workmanlike installation of all wiring per applicable code chapters. The document requires signature acceptance from both the owner and contractor, including a Construction Specialist, though specific pricing, bid submission dates, and award information are not completed in this work write-up document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 717_Elmwood_Ave_-_Electrical_to_Code.pdf | ||
| Maintenance_and_Guarantee_Bond.pdf | ||
| All_Services_Sample_Contract_.docx | DOCX document | |
| Labor_and_Material_Payment_Bond.pdf | ||
| CDBG_Additional_Forms.pdf | ||
| Performance_Bond.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Work Write-Up
E02 – ELECTRICAL TO CODE
* EXHIBIT 1 *
Dated: 6/23/2026
CUSTOMER INFORMATION
John ODowd 3418 Caroline Dr , Jackson, MI 49203
PREPARED BY
sharrison@cityofjackson.org
* NOTE *
THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF
1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT
2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP
Location: Unassigned
| Electrical System |
| Quantity |
| Units |
| Total |
1 - E02 – ELECTRICAL TO CODE
(Specification ID:80.00000 )
EA
* PERMIT REQUIRED *
Correct all existing violations or hazardous conditions existing in this structure as specified in the Housing Code and Electrical Regulations as to existing structures, as well as those included below.
I, the Electrical Contractor, shall perform the following alterations or installations stated below and shall further assure that upon completion, the structure shall be in compliance with the respective codes and permit requirements for the agreed contract price.
A change order must be executed by the Rehabilitation Specialist prior to installation of any "wiremold" or similar exposed wiring in living areas. • Fixture allowance included in bid: $ 500.00. See specs for additional electrical items.
Note: Electrical Contractor shall be responsible for all wall and ceiling repairs from any holes that were needed to run wire. Wall repairs shall be smooth, and sanded and ready for paint, owner responsible for painting. Repair of holes shall be done with plaster so as to match the existing materials.
Contractor responsible for daily cleanup.
All new outlets shall be wired with a constant feed unless specifically listed to provide switched lighting.
To include the following.
1: Install new 200- amp service panel (DUPLEX), disconnect, meter base, riser, service wire grounding and bonding per MRC code 2023 2: Install of a hard wire smoke and carbon monoxide detector in basement, to include interconnected if hardwire cannot be done, then radio frequency interconnect with 10-year lithium battery. Smokes according to MRC 2015.
3: New dedicated circuit for furnace.
4: Basement, remove all unused wiring. To include all cable.
5: Basement, any existing wiring shall be run in a workman like manner. Per chapter 3 8 of MRC 2015.
6: Basement, Install of four service lights. One within 10ft the service panel, one within 10ft of the furnace, the other two spaced evenly in remaining space.
7: Basement, One GFCI outlet at the service panel and one on the furnace.
8: Kitchen, install 2 dedicated 20-amp circuits with GFCI protection and receptacles spaced according to chapter 39 of the MRC.
9: Bathroom, install 1 dedicated 20-amp circuit with GFCI protection and lights. GFCI and lights.
10: Remove and replace knob and tube wiring and replace using the 6 / 12 rule of the MRC 2015.
11: New dedicated circuit for the water heater 12: Provide exterior lights at the front and rear door.
14: Provide exterior tamper resistant/ weather resistant GFCI receptacles at front and rear doors.
Electrical Contractor Name:
Permit Number:
Total
Prepared By: sharrison@cityofjackson.org on 6/23/2026
OWNER ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.
| x_________________________ | __________ | |
| Owner: | Date |
CONTRACTOR ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.
| x_________________________ | __________ | |
| Contractor | Date |
| x____________________________ | __________ | |
| Construction Specialist | Date |
| Prepared By: sharrison@cityofjackson.org on 6/23/2026 |