P10364042Dwgs1-31.pdf
PDF 14 MB Posted
- Attached to
- USCG AIRSTATION CLEARWATER: Major Repairs AIRSTA Clearwater and Repair Water Intrusion - Annex
- Solicitation number
- 70Z0G119BBF2221000
About this file
Drawing P10364042 Page 1-31
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Abstract_19-B-BF2221.pdf | ||
| Amendment0002_19-B-BF2221.pdf | ||
| Amendment0001_19-B-BF2221.pdf | ||
| P10364042Dwgs32-62.pdf | ||
| P10364042Specs_Reduced.pdf | ||
| P10276005Dwgs.pdf | ||
| P10276005Specs.pdf | ||
| IFB_70Z0G119BBF222100.pdf | ||
| General_Decision_Number_FL190222_02012019.pdf | ||
| Standard_Form_24.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UNITED STATES COAST GUARD
CIVIL ENGINEERING UNIT PROVIDENCE
MAJOR REPAIRS
CG AIRSTATION CLEARWATER
PSN 10364042
CLEARWATER, FLORIDA
(PINELLAS COUNTY)
NOT TO SCALE
LOCATION MAP
NOT TO SCALE
VICINITY MAP
PROJECT LOCATION
SHEET # APPLICABLE TO BID OPTION SHEET TITLEDWG #
DRAWING INDEX
SHEET # SHEET TITLEDWG # SHEET # SHEET TITLEDWG #
PROJECT LOCATION
1 OF 62 G-001
2 OF 62 G-002
3 OF 62 G-003
4 OF 62 S-001
5 OF 62 E-001
RPUID 7904 – EXCHANGE BUILDING
6 OF 62 AD101A
7 OF 62 AD201A
8 OF 62 A-101A
9 OF 62 A-201A
RPUID 67087 – SAFETY TRAILER
10 OF 62 AD101B
11 OF 62 AD201B
12 OF 62 A-101B
13 OF 62 A-201B
14 OF 62 S-101B
RPUID 7902 - FIXED WING HANGAR
15 OF 62 E-101C
RPUID 7903 – ROTARY HANGAR
16 OF 62 E-101D
RPUID 810701 – ARMORY
17 OF 62 AD101E
18 OF 62 A-101E
19 OF 62 A-501E
20 OF 62 S-101E
21 OF 62 E-101E
22 OF 62 E-501E
RPUID 67090 – C130 AIRCRAFT EQUIPMENT SHED
23 OF 62 AD101F
24 OF 62 A-101F
RPUID 7908 – BEQ – BASE ENLISTED QUARTERS
25 OF 62 AD101G
26 OF 62 A-101G
27 OF 62 A-501G
RPUID 7907 - BOQ - BASE OFFICER QUARTERS
28 OF 62 AD101H
29 OF 62 A-101H
30 OF 62 A-201H
31 OF 62 A-501H
32 OF 62 E-101H
33 OF 62 E-102H
34 OF 62 E-501H
RPUID 7906 - GALLEY
35 OF 62 AD101J
36 OF 62 A-101J
37 OF 62 A-501J
RPUID 7905 – DISPENSARY/ MED CLINIC
38 OF 62 AD101K
39 OF 62 AD102K
40 OF 62 AD201K
41 OF 62 A-101K
42 OF 62 A-102K
43 OF 62 A-201K
44 OF 62 S-101K
45 OF 62 S-301K
46 OF 62 MD101K
47 OF 62 MD102K
48 OF 62 M-101K
49 OF 62 M-102K
50 OF 62 M-501K
51 OF 62 M-701K
52 OF 62 ED101K
53 OF 62 ED102K
54 OF 62 E-101K
55 OF 62 E-102K
56 OF 62 E-103K
57 OF 62 E-501K
RPUID 7933 - WATER SURVIVAL TRAINING FACILITY
58 OF 62 A-101L
RPUID 7958 EXCHANGE OFFICE
59 OF 62 AD101M
60 OF 62 AD201M
61 OF 62 A-101M
62 OF 62 A-201M
TITLE SHEET
SITE PLAN, PHASING AND NOTES
SYMBOLS, ABBREVIATIONS & NOTES
GENERAL STRUCTURAL NOTES
NOTES, ABBREVIATIONS & LEGEND
ROOF PLAN - DEMOLITION
ELEVATIONS - DEMOLITION
ROOF PLAN
ELEVATIONS
FLOOR AND ROOF PLANS - DEMOLITION
ELEVATIONS DEMOLITION
FLOOR AND ROOF PLAN
ELEVATIONS
NEW WORK PLAN
PLAN, PHOTOS, SINGLE LINE DIAGRAM
DETAILS
FLOOR PLAN - DEMOLITION
PLANS & ELEVATIONS
DETAILS
CANOPY FOUNDATION PLAN
LIGHTNING PROTECTION
LIGHTNING PROTECTION DETAILS
ROOF PLAN - DEMOLITION
PLAN & ELEVATION
SOFFIT PLAN - DEMO
SOFFIT PLAN & ELEVATIONS
DETAILS
ROOF - DEMOLITION
ROOF PLAN & SECTION
ELEVATIONS - NEW WORK
DETAILS - NEW WORK
FLOOR PLAN
LIGHTNING PROTECTION
LIGHTNING PROTECTION DETAILS
SOFFIT - DEMOLITION PLAN
SOFFIT PLAN & ELEVATIONS
DETAILS
FLOOR PLAN - DEMOLITION
ROOF PLAN - DEMOLITION
ELEVATIONS - DEMOLITION
PARTIAL FLOOR PLAN
ROOF PLAN
ELEVATIONS - NEW WORK
NEW WORK ROOF PLAN
SECTIONS AND DETAILS
FLOOR PLAN - DEMOLITION
ROOF PLAN - DEMOLITION
FLOOR PLAN
ROOF PLAN
DETAILS
SCHEDULES
REFLECTED CEILING PLAN - DEMOLITION
ROOF PLAN - DEMOLITION
FLOOR PLAN
ROOF PLAN
LIGHTNING PROTECTION
LIGHTNING PROTECTION DETAILS
ROOF PLAN
ROOF PLAN - DEMOLITON
ELEVATIONS - DEMOLITION
ROOF PLAN
ELEVATIONS
BASE 1 2 3
APPLICABLE TO BID OPTION APPLICABLE TO BID OPTION
BASE 1 2 3 BASE 1 2 3
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
GOSSELIN.GERALD.G.127117
Digitally signed by
GOSSELIN.GERALD.G.1271179576
Date: 2019.04.15 11:01:22 -04'00'
A. RPUID 7904 – EXCHANGE BUILDING - PHASE 2
B. RPUID 67087 – SAFETY TRAILER - PHASE 2
C. RPUID 7902 – FIXED WING HANGAR - PHASE 2
D. RPUID 7903 – ROTARY HANGAR - PHASE 1
E. RPUID 810701 – ARMORY - PHASE 1
F. RPUID 67090 – C130 AIRCRAFT EQUIPMENT SHED - PHASE 2
G. RPUID 7908 – BEQ – BASE ENLISTED QUARTERS - PHASE 2
H. RPUID 7907 – BOQ – BASE OFFICER QUARTERS - PHASE 1
J. RPUID 7906 – GALLEY - PHASE 1
K. RPUID 7905 – DISPENSARY/ MED CLINIC - PHASE 3
L. RPUID 7933 – WATER SURVIVAL TRAINING FACILITY - PHASE 2
M. RPUID 7958 - EXCHANGE OFFICE - PHASE 1
NOTE:
1. THERE WILL BE OTHER WORK PERFORMED UNDER DIFFERENT CONTRACT AT THE HANGAR BUILDINGS DURING THE SAME TIME PERIOD AS
THIS CONTRACT. CONTRACTOR TO COORDINATE THE WORK THAT WILL BE PERFORMED UNDER THIS CONTRACT IN THE HANGARS WITH THE
COR FOR ACCESS TO THE BUILDINGS.
2. CONTRACTOR IS RESPONSIBLE TO SECURE THEIR CONEX BOXES, TRAILERS AND EQUIPMENT. WORK WILL BE DURING THE HURRICANE
SEASON.
3. FIRE LANE/ACCESS NEEDS TO REMAIN OPEN THROUGH CONTRACTOR LAY DOWN AREA/PARKING TO BOQ AND ROADWAY TO PAST GALLEY.
WE RECOMMEND PARKING NOT BE FENCED OFF THROUGH THAT AREA.
E
D
G
J
F
H
L
A B
C
NOT TO SCALE
SITE PLANA4
CONTRACTOR
LAYDOWN AREA
AND PARKING
AREA OF OTHER
WORK UNDER
CONSTRUCTION
DURING THE SAME
TIME PERIOD
1. COMPLETE PHASE I PRIOR TO STARTING PHASE II.
2. PROVIDE A WEEK AFTER FINISHING THE RPUID 7907
BOQ, BEFORE STARTING CONSTRUCTION ON RPUID
7908 BEQ TO ALLOW BASE TO MOVE OCCUPANTS
AND FURNITURE BETWEEN THE TWO FACILITIES.
3. PHASE III – PROVIDE 45 DAYS’ NOTICE TO BASE
PRIOR TO STARTING THE PROJECT. THIS CAN BE AT
THE SAME TIME WITH OTHER PHASES. HAVE ALL
MATERIALS AND EQUIPMENT NECESSARY ON SITE
PRIOR TO STARTING THE WORK IN ORDER TO
MINIMIZE CONSTRUCTION TIME ON THE MED CLINIC.
4. PAVING PROJECT IS STARTING IN NOVEMBER AND
END IN APRIL – FOR THE APRON BETWEEN AND
AROUND THE TWO LARGE HANGARS. WORK AT THE
HANGAR SHOULD BE COORDINATED WITH COR.
5. BEQ, BOQ AND THE MED CLINIC WILL BE VACATED
DURING CONSTRUCTION. ALL OTHER BUILDINGS
WILL REMAIN IN OPERATIONS.
PHASING NOTES
PROJECT PHASES
PHASE I:
RPUID 7906 GALLEY
RPUID 7907 BOQ
RPUID 810701 ARMORY
RPUID 7903 ROTARY HANGAR
RPUID 7958 EXCHANGE OFFICE
PHASE II:
RPUID 7904 EXCHANGE BUILDING
RPUID 67087 SAFETY TRAILER
RPUID 7902 FIXED WING HANGAR
RPUID 67090 C130 AIRCRAFT EQUIPMENT SHED
RPUID 7908 BEQ
RPUID 7933 WATER SURVIVAL TRAINING FACILITY
PHASE III:
RPUID 7905 DISPENSARY/MED CLINIC
M
K
GENERAL SHEET NOTES
1. ALL DIMENSIONS SHOWN ARE APPROXIMATE. BIDDERS ARE RESPONSIBLE
TO VERIFY ALL DIMENSIONS, EXISTING CONDITIONS AND QUANTITIES
PRIOR TO FABRICATION.
2. COMPONENTS OF THE PROPOSED CONSTRUCTIONS SHALL MEET ALL
APPLICABLE CODES AND REGULATIONS.
3. THE CONTRACTOR SHALL REPORT ANY DETERIORATED OR UNSUITABLE
SUBSTRATES / EXIST. MATERIALS THAT ARE INDICATED TO REMAIN, TO THE
CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO PERFORMING NEW
WORK.
4. CONTRACTOR SHALL DISCONNECT, PROTECT, REMOVE, REINSTALL AND
RECONNECT ALL EXISTING ELECTRICAL CONDUITS, LIGHT FIXTURES, ANY
MEP PENETRATIONS AS REQUIRED TO COMPLETE THE PROPOSED WORK.
5. PORTIONS OF THE EXISTING BUILDING WILL BE OCCUPIED AND REMAIN IN
USE DURING ALL PHASES OF CONSTRUCTION. BEFORE COMMENCEMENT
OF WORK, THE CONTRACTOR SHALL COORDINATE WITH THE
CONTRACTING OFFICER AND BUILDING CUSTOMER ANY WORK OR
PROCEDURES THAT WILL INTERRUPT ACTIVITIES IN AND/OR AROUND THE
BUILDING.
6. WHERE DEMOLITION IS INDICATED ON THE DRAWINGS, OR REQUIRED FOR
INSTALLATION OF NEW CONSTRUCTION, REMOVE EXISTING
CONSTRUCTION (I.E. AREAS OF FLOORS, WALLS, CEILINGS, ROOFS, ETC)
TO PERFORM THE WORK INDICATED.
7. WHERE DEMOLITION WORK HAS OCCURRED AND RESTORATION OF
FLOORS, WALLS, CEILINGS, ROOF ETC IS REQUIRED (I.E. EXISTING
CONSTRUCTION TO REMAIN EXPOSED TO VIEW), PATCH AND/OR REPAIR
SURFACES TO MATCH EXISTING ADJACENT SURFACE CONDITIONS AND
FINISHES TO REMAIN.
8. PATCHING AND PAINTING: HOLES IN FLOORS, CEILINGS AND WALLS
CAUSED BY THIS SCOPE OF WORK AND EXISTING HOLES IN VISIBLE
FINISHED SPACES SHALL BE FILLED, SEALED AND PAINTED NEATLY WITH
MATERIAL TO MATCH EXISTING ADJACENT MATERIAL AND FINISH. PAINTING
OF EXISTING WALLS SHALL BE FROM FLOOR TO TOP OF WALL AND FROM
CORNER TO CORNER, UNLESS OTHERWISE NOTED.
9. LEAD AND ASBESTOS SURVEY WAS PERFORMED AT THE PROJECT
FACILITIES AND IS ATTACHED TO THE SPECIFICATION. ALL HAZARDOUS
MATERIALS IN AREAS DISTURBED BY THIS CONTRACT SHALL BE ABATED. IF
LEAD OR ASBESTOS ARE ENCOUNTERED IN LOCATION OUTSIDE OF THE
REPORT, NOTIFY THE CONTRACTING OFFICER IMMEDIATELY.
BID OPTION ITEMS-CONTINUED
SHEET ON WHICH
DETAIL IS REFERENCED
DETAIL
LETTER
X-XXX
X
X
X
X
X
XXX
PLAN TITLE OR
TYPICAL DETAIL
GENERAL SYMBOLS
TRUE NORTH ARROW
REFERENCED
DETAIL BUBBLE REFERENCED
ELEVATION SYMBOL
ELEVATION
LETTER
SHEET ON
WHICH
SECTION IS
REFERENCED
SECTION
NUMBER
ELEVATION
LETTER
REFERENCED MULTIPLE
INTERIOR ELEVATION SYMBOL
DIRECTION
OF VIEW
SECTION IS
TAKEN
SHEET ON WHICH
ELEVATIONS ARE
REFERENCED
REFERENCED
SECTION SYMBOL
SHEET ON
WHICH
ELEVATION IS
REFERENCED
VIEW TITLE
COORDINATE NUMBER
DATUM ELEVATION
EXISTING CONSTRUCTION TO BE REMOVED
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
SHEET KEYNOTE
ROOM NAME
101 ROOM IDENTIFIER, NAME AND NUMBER
REVISION TAGX
X
INTERIOR
XX
XXXXXX
DISCIPLINE
SHEET
NUMBER
SUB DISCIPLINE OR A DASH
FOR PLACEHOLDER
BUILDING IDENTIFIER
DRAWING NAMING CONVENTION
X
XX
X-XXX
X
EXTERIOR
RPUID 67087 – SAFETY TRAILER
A. ARCHITECTURE
1. DAMAGED EXTERIOR ENVELOPE SHALL BE REMOVED AND REPLACED UNDER UNIT
PRICE NO. 5.
2. UNIT PRICE NO. 5 ESTIMATED QUANTITY: 16'-0" LONG X 13'-6" HIGH AREA OF EXTERIOR
WALL (216 SF).
3. SALVAGE WINDOWS WITHIN AREA OF WALL DEMOLITION FOR REINSTALLATION.
4. PROVIDE NEW CARPET AND WALL BASE.
5. DEMOLISH AND REPLACE 100 SF OF CARPET TILE TO MATCH EXISTING.
6. DEMOLISH MEMBRANE ROOF SYSTEM DOWN TO ROOF DECK. PROVIDE NEW TAPERED
INSULATION, 3-PLY MODIFIED BITUMINOUS ROOF SYSTEM, GUTTERS, DOWNSPOUTS
AND SPLASH BLOCKS.
7. REMOVE AND REINSTALL (2) RECEPTACLES ON WALL NEEDING REPAIR.
B. STRUCTURAL
1. DAMAGED STRUCTURAL ELEMENTS ARE TO BE REMOVED AND REPLACED IN KIND.
DAMAGE IS PRESUMED TO EXTEND A MINIMUM OF 8’-0” IN EACH DIRECTION FROM THE
NORTHWEST CORNER OF THE BUILDING.
2. UNIT PRICE NO. 3 ESTIMATED QUANTITY: 16'-0" LONG X 13'-6" TALL SECTION OF WALL
(216SF).
3. UNIT PRICE NO. 4 ESTIMATED QUANTITY: 8'-0"X8'-0" SQUARE PORTION OF THE ROOF
(64SF).
RPUID 7902 – FIXED WING HANGAR:
A. ELECTRICAL
1. REPLACE 800A MAIN CIRCUIT BREAKER IN PANEL MDP5.
2. REPLACE CIRCUIT BREAKER IN PANEL DP5 – NW.
3. PROVIDE GROUND BAR IN THE EXISTING AUTOMATIC TRANSFER SWITCH.
4. PROVIDE EQUIPMENT GROUNDING CONDUCTOR FROM ATS TO THE ENCLOSED
CIRCUIT BREAKER AND FROM ATS TO PANEL DP5-NW.
RPUID 7903 – ROTARY HANGAR:
A. ELECTRICAL
1. REPLACE 200A CIRCUIT BREAKER IN PANEL DP6-W.
RPUID 7908 – BEQ – BASE ENLISTED QUARTERS:
A. ARCHITECTURE
1. REPLACE EXISTING VENTED SOFFIT WITH THE NEW ALUMINUM VENTED METAL SOFFIT
PANEL SYSTEM.
2. REPLACE GUTTER & DOWNSPOUT.
3. PATCH CRACKS & HOLES IN THE STUCCO FAÇADE.
4. REMOVE DETERIORATED SEALANTS FOR THE CORNERS AND JOINTS, REPLACE WITH
NEW SILICON BASED SEALANTS.
5. APPLY WATERPROOF ELASTOMERIC COATING ON ENTIRE STUCCO FACADE.
6. REPLACE EXISTING CORRODED LOUVER WITH NEW LOUVER.
7. UNIT PRICE NO. 2 ESTIMATED QUANTITY: 40 BOARD FOOT.
8. UNIT PRICE NO. 6 ESTIMATED QUANTITY: 200 LF.
9. UNIT PRICE NO. 7 ESTIMATED QUANTITY: 100 LF.
10. REPLACE LIGHTING FIXTURES AT THE SOFFIT.
RPUID 7907 – BOQ – BASE OFFICER QUARTERS:
A. ARCHITECTURE
1. REPLACE EXISTING WATER DAMAGED SECTION OF GYPSUM WALL BOARD AND VINYL
BASE WITH NEW GYPSUM WALL BOARD AND VINYL COVE BASE TO MATCH EXISTING.
PAINT THE REPAIRED WALL FROM CORNER TO CORNER.
2. REPLACE EXISTING ASPHALT SHINGLES ROOF, INCLUDING GUTTERS, DOWNSPOUTS,
FASCIA AND OTHER ROOF ACCESSORIES, WITH NEW STANDING SEAM METAL ROOF,
GUTTER, FASCIA, DOWNSPOUTS AND SPLASH BLOCK.
3. REMOVE EXIST. BATT INSULATION COMPLETELY FROM THE ENTIRE ATTIC AREA.
4. PROVIDE R-25 OPEN CELL SPRAY FOAM INSULATION AT THE UNDERSIDE OF THE
ENTIRE ROOF DECK.
5. REMOVE WATER DAMAGED STUCCO AND REPLACE WITH NEW STUCCO SYSTEM.
6. PATCH CRACKS & HOLES IN THE STUCCO FAÇADE.
7. REMOVE DETERIORATED SEALANTS AT THE CORNERS AND JOINTS, REPLACE WITH
NEW SILICON BASED SEALANTS.
8. APPLY WATERPROOF ELASTOMERIC COATING ON ENTIRE STUCCO FACADE.
9. UNIT PRICE NO. 1 ESTIMATED QUANTITY: 600 SF.
10. UNIT PRICE NO. 2 ESTIMATED QUANTITY: 60 BOARD FOOT.
11. UNIT PRICE NO. 6 ESTIMATED QUANTITY: 200 LF.
12. UNIT PRICE NO. 7 ESTIMATED QUANTITY: 75 LF.
13. REPLACE SOFFIT LIGHTING.
B. ELECTRICAL
1. COORDINATE CONDUIT REMOVAL/REPLACEMENT WITH ARCHITECTURAL FOR
INTERIOR WALL REPAIRS.
2. PROVIDE LIGHTNING PROTECTION SYSTEM.
RPUID 7906 – GALLEY:
A. ARCHITECTURE
1. REPLACE EXISTING VENTED SOFFIT WITH THE NEW ALUMINUM VENTED METAL SOFFIT
PANEL SYSTEM.
2. REPLACE GUTTER & DOWNSPOUT.
3. PATCH CRACKS & HOLES IN THE STUCCO FAÇADE.
4. REPAIR STUCCO SPALL.
5. REMOVE DETERIORATED SEALANTS FOR THE CORNERS AND JOINTS, REPLACE WITH
NEW SILICON BASED SEALANTS.
6. APPLY WATERPROOF ELASTOMERIC COATING ON ENTIRE STUCCO FACADE.
7. UNIT PRICE NO. 2 ESTIMATED QUANTITY: 40 BOARD FOOT.
8. UNIT PRICE NO. 6 ESTIMATED QUANTITY: 500 LF.
9. UNIT PRICE NO. 7 ESTIMATED QUANTITY: 100 LF.
10. REPLACE SOFFIT LIGHTING.
RPUID 7905 – DISPENSARY/ MED CLINIC:
A. ARCHITECTURE
1. DEMOLISH AND REPLACE ROOF MEMBRANE WITH 3-PLY MODIFIED BITUMINOUS ROOF.
2. REPLACE ROOF INSULATION WITH MINIMUM R-25 TAPERED INSULATION AND PROVIDE
COVER BOARD
3. DEMOLISH CONDUCTOR HEADS AND DOWNSPOUTS AND PROVIDE NEW GUTTERS,
DOWNSPOUTS AND SPLASH BLOCKS.
4. PROVIDE PREFABRICATED ROOF CURBS FOR ALL MECHANICAL EQUIPMENT.
5. PROVIDE ROOF WALKPADS AT ALL MECHANICAL EQUIPMENT LOCATIONS
6. PROVIDE LIQUID FLASHING AT ALL ROOF PENETRATIONS.
7. DEMOLISH AND REPLACE/MODIFY EXISTING GYPSUM BOARD CEILINGS.
B. STRUCTURAL
1. PROVIDE STRUCTURAL STEEL SUPPORTS FOR NEW MECHANICAL ROOFTOP
EQUIPMENT.
2. PROVIDE STRUCTURAL STEEL FRAMING TO INFILL AN EXISTING ROOF OPENING.
3. PROVIDE NEW STEEL LADDER FOR ROOF ACCESS ON THE BUILDING'S EXTERIOR.
C. MECHANICAL
1. REPLACE THE THREE EXISTING ROOFTOP UNITS WITH TWO 7.5-TON PACKAGED
ROOFTOP HEAT PUMPS AND ONE NEW EXISTING 5-TON ROOFTOP HEAT PUMP.
2. ALL NEW UNITS SHALL BE INSTALLED WITH NEW ROOF CURBS AND SHALL HAVE AN
ELECTRIC AUXILIARY HEATING COIL.
3. REMOVE ONE EXISTING SPLIT SYSTEM AIR HANDLER AND OUTDOOR UNIT AND
ASSOCIATED DUCT SYSTEM. INSTALL A NEW VARIABLE AIR VOLUME DUCT SYSTEM TO
REPLACE THE REMOVED SPLIT SYSTEM.
4. REMOVE TWO EXISTING ROOFTOP EXHAUST FANS THAT ARE NO LONGER ACTIVE AND
WERE ABANDONED IN PLACE. REMOVE THE ASSOCIATED ROOF CURBS AND PATCH
THE ROOF.
5. REPLACE TWO ROOFTOP EXHAUST FANS (CENTRIFUGAL DOWN-BLAST TYPE) AND
THEIR ROOF CURBS.
6. NEW FANS TO BE CENTRIFUGAL DOWN-BLAST TYPE EXHAUST FANS, 400 CFM, 120
VOLT EACH.
D. ELECTRICAL
1. PROVIDE ELECTRICAL WORK TO SUPPORT MECHANICAL UPGRADE.
2. PROVIDE LIGHTNING PROTECTION SYSTEM REPLACEMENT.
BID OPTION 1
RPUID 7904 – EXCHANGE BUILDING
A. ARCHITECTURE
1. DEMOLISH AND REPLACE METAL SOFFIT. SOFFIT DEPTH IS 2’-6”.
2. DEMOLISH AND REPLACE (8) 5.5” X 4” DOWNSPOUTS
3. PROVIDE NEW SPLASH BLOCK AT EACH DOWNSPOUT
4. PROVIDE AN INDUSTRIAL ELASTOMERIC METAL ROOF COATING ON THE
EXISTING METAL ROOF AND GUTTER
5. PROVIDE LEAF GUARD AT GUTTERS.
BID OPTION 2
RPUID 810701 – ARMORY:
A. ARCHITECTURE
1. REPLACE EXISTING CANOPY ROOF WITH STRUCTURAL STANDING SEAM METAL ROOF
INCLUDING GUTTER, DOWNSPOUTS AND SPLASH BLOCKS.
B. STRUCTURAL
1. DEMOLISH EXISTING METAL CANOPY AND REPLACE WITH A NEW PRE-ENGINEERED
METAL CANOPY STRUCTURE.
2. DEMOLISH A PORTION OF THE EXISTING SLAB-ON-GRADE TO ACCOMMODATE FOR THE
A NEW GRADE BEAM FOUNDATION SYSTEM TO BE CONSTRUCTED AROUND THE
PERIMETER.
C. ELECTRICAL
1. PROVIDE LIGHTING PROTECTION SYSTEM FOR NEW ARMORY CANOPY.
2. PROVIDE LIGHTNING PROTECTION SYSTEM REPLACEMENT FOR NEW CANOPY.
3. REMOVE AND REPLACE CCTV SYSTEM.
RPUID 7958 - EXCHANGE OFFICE
D. ARCHITECTURE
1. DEMOLISH AND REPLACE METAL SOFFITS.
2. DEMOLISH AND REPLACE DOWNSPOUTS
3. DEMOLISH AND REPLACE SPLASH BLOCKS AT DOWNSPOUT LOCATIONS
4. PROVIDE AN INDUSTRIAL ELASTOMERIC METAL ROOF COATING ON THE EXISTING
METAL ROOF AND GUTTER
5. PROVIDE LEAF GUARDS AT GUTTERS.
BID OPTION 3
RPUID 7933 – WATER SURVIVAL TRAINING FACILITY:
A. ARCHITECTURE
1. AT THE HIGH ROOF SECTION SEAL HORIZONTAL AND VERTICAL SEAM JOINTS WITH
COMPATIBLE SEAM SEALER.
RPUID 67090 - C130 EQUIPMENT SHED
A. ARCHITECTURE
1. DEMOLISH AND REPLACE METAL FASCIA
2. DEMOLISH AND REPLACE METAL GUTTER AND DOWNSPOUT
MATERIAL SYMBOLS
CONCRETE
MASONRY UNIT
EXTERIOR FINISH
MASONRY UNIT
GRAVEL
EARTH CONCRETE
INSULATION
(BLANKET, BATT)
RIGID INSULATION
STEEL IN SECTION
PLYWOOD
GYPSUM
WALLBOARD
COMPOSITE
METAL PANEL
WOOD BLOCKING
BASE BID ITEMS BASE BID ITEMS-CONTINUED
ABBREVIATIONS
A/C AIR CONDITION
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALM ALARM
ALT ALTERNATE
ALUM ALUMINUM
APPD APPROVED
APPROX APPROXIMATE
ARCH ARCHITECT
ASTM AMERICAN SOCIETY FOR TESTING MATERIALS
AVG AVERAGE
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLW BELOW
BOT BOTTOM
BTWN BETWEEN
CALC CALCULATE
CAP CAPACITY
CJ CONSTRUCTION JOINT, CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COEFF COEFFICIENT
COL COLUMN
COMM COMMUNICATION
CONC CONCENTRIC, CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUE, CONTROLLER
CONTR CONTRACT, CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER’S REPRESENTATIVE
CORR CORRIDOR
CPT CARPET, CONTROL POWER TRANSFORMER
CTG COATING
CTR CENTER
CTRL CONTROL
DBL DOUBLE
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIAG DIAGRAM
DIM DIMENSION
DIR DIRECTION
DIST DISTANCE
DIV DIVISION
DL DEAD LOAD
DR DOOR
DS DOWN SPOUT W/ SPLASH BLOCK
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR, EXTERNAL, EXTINGUISHER
FA FIRE ALARM, FRESH AIR
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER W/CABINET
FF FINISHED FLOOR
FF&E FURNITURE, FIXTURE & EQUIPMENT
FIN FINISH
FLR FLOOR
FT FOOT, FEET
FTG FOOTING
GALV GALVANIZED
GC GENERAL CONTRACTOR
GD GUARD
GEN GENERAL, GENERATOR
GYP BD GYPSUM BOARD
GYP GYPSUM
HAZ HAZARD
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATING & AIR CONDITIONING
ID INSIDE DIAMETER, INSIDE DIMENSION
INCL INCLUDED
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
J-BOX JUNCTION BOX
L ANGLE
LB POUND
LF LINEAR FEET
LL LIVE LOAD
LT LIGHT
LVL LEVEL
LVR LOUVER
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL ELECTRICAL PLUMBING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD BIT MODIFIED BITUMEN
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
NT WT NET WEIGHT
OC ON CENTER
OCC OCCUPY, OCCUPANCY
OD OUTSIDE DIAMETER
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
PAT PATTERN
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PH PHASE
PLAM PLASTIC LAMINATE
PLAT PLATFORM
PLBG PLUMBING
PLYWD PLYWOOD
PREFAB PREFABRICATE
PRELIM PRELIMINARY
PROJ PROJECT
PT PAINT, PRESSURE TREATED
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
QUAD QUADRANGLE, QUADRANT
R RADIUS, RISER
RCP REFLECTED CEILING PLAN, REINF CONC PIPE
RD ROAD, ROOF DRAIN
REF REFERENCE, REFRIGERATION
REINF REINFORCE(D)
REQ'D REQUIRED
REV REVISION
RFI REQUEST FOR INFORMATION
RO ROUGH OPENING
SECT SECTION
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SLNT SEALANT
SPEC SPECIFICATION
SST STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STL STEEL
STD STANDARD
STOR STORAGE
STRUCT STRUCTURAL
SUM SUMMARY
SYM SYMBOL
SYS SYSTEM
TO TOP OF ______
TOC TOP OF CONCRETE, TOP OF CURB
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOPO TOPOGRAPHY
TOW TOP OF WALL
TOS TOP OF SLAB, TOP OF STEEL
TS TUBE STEEL
TSTAT THERMOSTAT
TYP. TYPICAL
UL UNDERWRITERS LABORATORIES
UN UNLESS NOTED
UNO UNLESS NOTED OTHERWISE
VAR VARIATION, VARIES, VOLT AMPERES REACTIVE
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE, VITRIFIED CLAY TILE
VEL VELOCITY
VENT VENTILATOR
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VENT THRU ROOF
W WASTE, WATT, WIDE
W/ WITH
WD WOOD, WOOD DOOR
WL WIND LOAD
W/O WITHOUT
WP WATER PROOFING, WEATHERPROOF, WORKING
POINT
16'8'4'0
GRAPHIC SCALE
NOT TO SCALE
UNIT PRICE ITEMS
1. UNIT PRICE NO. 1: REPLACE DAMAGED PLYWOOD ROOF SHEATHING.
2. UNIT PRICE NO. 2: REPLACE DAMAGED DIMENSIONAL LUMBER.
3. UNIT PRICE NO. 3: CONTRACTOR SHALL REPAIR THE EXISTING WALL FRAMING AND SHEATHING, SILL
PLATES, METAL CONNECTORS, ETC. REMOVE DAMAGED STRUCTURAL WOOD WALL FRAMING AND
SHEATHING AND REPLACE FRAMING IN KIND.
4. UNIT PRICE NO. 4: CONTRACTOR SHALL REPAIR THE EXISTING ROOF FRAMING AND SHEATHING, METAL CONNECTORS, ETC. REMOVE DAMAGED STRUCTURAL WOOD ROOF FRAMING AND SHEATHING
AND REPLACE FRAMING IN KIND. IF ROOF JOIST SPAN EXCEEDS BEYOND THE PRESUMED AREA OF
DAMAGE, THE FULL LENGTH OF THE JOIST SHALL BE REPLACED.
5. UNIT PRICE NO. 5: CONTRACTOR SHALL REPAIR THE EXISTING EXTERIOR METAL WALL PANELS, BATT
INSULATION AND INTERIOR GYPSUM WALLBOARD.
6. UNIT PRICE NO. 6: REPAIR CRACKS 1/32-INCH TO 1/8-INCH WIDE IN STUCCO.
7. UNIT PRICE NO. 7: REPAIR CRACKS 1/8-INCH TO 1/4-INCH WIDE IN STUCCO
ESTIMATED QUANTITIES: SEE EACH RPUID UNDER THE BASE BID ITEMS FOR ESTIMATED UNIT PRICE
QUANTITY TO BE INCLUDED IN THE BASE BID.
BID OPTION ITEMS
D1
± 34'-0"
1:
S
LO
P E
TYP
EXIST ARMORY STORAGE
STRUCTURE BELOW TO REMAIN
EXIST ROTARY HANGAR BLDG (NIC)
D4
AD101E
B1
AD101E
C2
TYP
'-0
3'
-0
D2
TYP
EXIST CHAIN-LINK FENCE
DOUBLE SWING GATE
(± 13'-0" WIDE VIF);
REMOVE & SALVAGE FOR REUSE
EXIST CHAIN-LINK FENCE
SLIDING GATE (± 3'-6" WIDE VIF);
REMOVE & SALVAGE FOR REUSE
AD101E
C1
AD101E
B2EXIST CONC
WALKWAY
PAD TO REMAIN; PROTECT
WALKWAY PAD & PROVIDE
COMPRESSIBLE FILL
AND SEALANT AT THE JOINT
BETWWEN EXIST. PAD AND
NEW CONC. WORK
D3
D1. REMOVE METAL CANOPY IN ITS ENTIRETY INCLUDING ROOF, GUTTER,
DOWNSPOUTS, STRUCTURAL FRAMING, LIGHTING AND LIGHTNING
PROTECTION SYSTEM. .
D2. REMOVE CHAIN LINK FENCE INCLUDING POSTS AND BARBED WIRE.
SALVAGE DOUBLE SWING AND SLIDING GATES WITH ASSOCIATED POSTS,
HARDWARE AND BARBED WIRE FOR REUSE.
D3. REMOVE, SALVAGE AND REINSTALL CCTV CAMERAS. COORDINATE WITH
COR; SEE ELECTRICAL.
D4. SEE STRUCTURAL DWG S-101E FOR REMOVAL OF TWO-FEET WIDE CONC
FLOOR SLAB ALONG THE PERIMETER (INDICATED BY SHADED AREA).
SHEET KEYNOTES
8'4'0 2'
D1
TYP D1
TYP
EXIST. ROTARY HANGAR
BLDG (NIC).
D2
CANOPY PLAN - DEMOA3
SOUTH VIEWC2UNDERSIDE CANOPY VIEWC1
GENERAL SHEET NOTES
1. ALL WORK ON THIS SHEET IS FOR BID OPTION 2.
2. EXISTING ARMORY STORAGE SHALL REMAIN AT THE EXISTING LOCATION.
PROTECT ARMORY STORAGE DURING THE CONSTRUCTION INCLUDING
PORTION OF EXISTING CONC SLAB INDICATED TO REMAIN.
SLIDING GATEB2DOUBLE SWING GATEB1
EXIST. ARMORY STORAGE TO REMAIN
EXIST. CHAIN-LINK DOUBLE SWING GATE EXIST. SLIDING GATE
D3
1/4"=1'-0"
NOT TO SCALE
NOT TO SCALENOT TO SCALE
NOT TO SCALE
1/4"=1'-0"
INTEGRAL SHEET MTL.
GUTTER W/
DOWNSPOUTS &
SPLASH BLOCKS, TYP
34'-0"
STANDING SEAM METAL
CANOPY ROOF, TYP
STRUCTURAL CANOPY FRAMING
BELOW, TYP
: 1
S
LO
P
E
EXIST. ROTARY HANGAR BLDG. (NIC)
MAINTAIN HORIZONTAL
SEPARATION BETWEEN
THE NEW CANOPY & THE
ROTARY HANGAR BUILDING,
SAME AS EXISTING;
FIELD VERIFY
A-101E B3
A-101E C1
TYP
A-501E
C4
TYP
A-501E
C3
A-101E C3
A-101E B1
'-0
2' -0
2'
-0
2'-0" 2'-0"
D.S.D.S.D.S.
3'
-0
EXIST. CONC WALKWAY
PAD TO REMAIN
EDGE OF CONC.
FOUNDATION BELOW,
TYP
30'-0"
32'-0"
10'-8" 10'-8" 10'-8"
'-0
'-0
'-0
2'-0"
CANOPY
OVERHANG
2'-0"
CANOPY
OVERHANG
4' -6
4'
-6
'-0 " V
IF
M
A
TC
H W
I/ E
X S
T.
G
A
TE
W
ID
TH
2'-0" 26'-0" 2'-0"
2' -0
'-0
2' -0
1'-0"
1' -0
1'
-0
1'-0"
6'-4" 4'-4" 10'-8"
10'-8"
EXIST. ROTARY HANGAR BLDG. (NIC)
EXIST. CONC WALKWAY
PAD TO REMAIN
SLIDING GATE
DOUBLE
GATE
EXIST. ARMORY
STORAGE (NIC),
TO REMAIN IN PLACE
PORTION OF EXIST. CONC
SLAB TO REMAIN, TYP
PERIMETER CONC GRADE
BEAM, SEE STRUC.;
FINISHED CONC LVL TO
MATCH EXISTING, TYP
TYP
3 4
2 4
TYP
TYP
COLUMN, SEE STRUC, TYP
DOWNSPOUT W/
SPLASH BLOCK, TYP
2' -0
C
A N
O P
Y O
V E
R H
A N
G
EXTENT OF CANOPY
ROOF ABOVE, TYP
A3 A501E
TYP
A1 A501E
TYP
A2
A501E
TYP
STRUCTURAL CANOPY
FRAMING, TYP
SHEET METAL INTEGRAL
GUTTER WITH
DOWNSPOUTS, TYP
STANDING SEAM METAL
ROOF, TYP
CONC. GRADE BEAM AT
PERIMETER, SEE
STRUCTURAL, TYP
EXISTING ARMORY
STORAGE (NIC), TYP
6'
-0 " V
IF
C
H A
IN
-L
IN
K
H T.±
'-0 " V
IF
CHAIN LINK FENCE W/
BARBED WIRE AT TOP,
TYP
1'
-6 " V
IF
STRUCTURAL CANOPY
FRAMING, TYP
STANDING SEAM METAL
ROOF, TYP
CONC. GRADE BEAM AT
PERIMETER, SEE
STRUCTURAL, TYP
EXISTING ARMORY
STORAGE (NIC) TO
REMAIN, TYP
CHAIN LINK FENCE W/
BARBED WIRE AT TOP,
TYP
6'
-0 " V
IF
C
H A
IN
-L
IN
K
H T.±
'-0 " V
IF
1'
-6 " V
IF
1"=1'-0"
STRUCTURAL CANOPY
FRAMING, TYP
SHEET METAL INTEGRAL
GUTTER WITH
DOWNSPOUTS, TYP
STANDING SEAM METAL
ROOF, TYP
CONC. GRADE BEAM AT
PERIMETER, SEE
STRUCTURAL, TYP
EXISTING ARMORY
STORAGE (NIC) TO
REMAIN, TYP
CHAIN LINK FENCE W/
BARBED WIRE AT TOP,
TYP
6'
-0 " V
IF
C
H A
IN
-L
IN
K
H T.±
'-0 " V
IF
1'
-6 " V
IF
STRUCTURAL CANOPY
FRAMING, TYP
SHEET METAL INTEGRAL
GUTTER WITH
DOWNSPOUTS, TYP
STANDING SEAM METAL
ROOF, TYP
CONC. GRADE BEAM AT
PERIMETER, SEE
STRUCTURAL, TYP
EXISTING ARMORY
STORAGE (NIC) TO
REMAIN, TYP
CHAIN LINK FENCE W/
BARBED WIRE AT TOP,
TYP
6'
-0 " V
IF
C
H A
IN
-L
IN
K
H T.
'-1 0"
V
IF
1'
-6 " V
IF
1. PROVIDE PRE-ENGINEERED METAL CANOPY INCLUDING STRUCTURAL FRAMING, STANDING
SEAM METAL ROOF, GUTTER, DOWNSPOUTS, AND SPLASH BLOCK.
PRE-ENGINEERED METAL CANOPY NOTES:
A. SUBMIT DELEGATED DESIGN FOR STRUCTURAL PERFORMANCE OF PRE-ENGINEERED
METAL CANOPY, INCLUDING ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED
PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION. SEE STRUCT DWG,
FOR STRUCT DESIGN CRITERIA.
B. BASIS OF DESIGN: PROVIDE PRE-ENGINEERED METAL CANOPY FROM DUO-GARD
INDUSTRIES INC., 40442 KOPPERNICK ROAD, CANTON, MICHIGAN 48187.
C. STRUCTURAL FRAMING MATERIAL SHALL BE STEEL, SAND/BEAD BLASTED AND PAINTED
WITH TWO-PART TNEMEC EPOXY PAINT FINISH WITH "DURASHIELD" POLYURETHANE TOP
COAT. COLOR: WHITE.
D. STANDING SEAM METAL ROOF, GUTTER AND DOWNSPOUT MATERIAL SHALL BE 24 GA.
GALVALUME-COATED STANDING SEAM STEEL PANELS, WITH 3-COAT KYNAR 500 PAINT
FINISH ON EXPOSED SURFACES. COLOR: WHITE.
2. MODIFY EXISTING SLAB PERIMETER AND PROVIDE TWO FEET WIDE CONC GRADE BEAM AT
ALL AROUND PERIMETER. SEE STRUCTURAL DWG S-101E.
3. PROVIDE CHAIN LINK FENCE SYSTEM INCLUDING ASSOCIATED POSTS, CONC. FOOTINGS,
GATES, LOCKING HARDWARE, LIGHTNING PROTECTION AND BARBED WIRE.
CHAIN LINK FENCE NOTES:
A. CHAIN-LINK FENCE AND GATE FRAMEWORKS SHALL WITHSTAND THE DESIGN WIND LOADS
AND STRESSES FOR FENCE HEIGHT(S) AND UNDER EXPOSURE CONDITIONS INDICATED
ACCORDING TO ASCE/SEI 7. SEE STRUCT FOR DESIGN WIND LOAD. SUBMIT DELEGATED
DESIGN FOR STRUCTURAL PERFORMANCE OF CHAIN-LINK FENCE AND GATE FRAMEWORKS,
INCLUDING ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL
ENGINEER RESPONSIBLE FOR THEIR PREPARATION.
B. FENCING MATERIAL SHALL CONSIST OF CHAIN LINK FENCING. THE MAXIMUM
VERTICAL/HORIZONTAL OPENING DIMENSION SHALL BE 2-INCH. MINIMUM THICKNESS OF
WIRE SHALL BE 9 GAUGE .
C. THE FENCING FABRIC MUST BE EXTENDED TO WITHIN 2-INCH OF FIRM GROUND.
D. ALL FENCING MATERIAL SHALL BE GALVANIZED STEEL OR ALUMINUM COATED STEEL
FABRIC.
E. FENCE POSTS SHALL BE INSTALLED PLUMB AND CHECKED FOR ALIGNMENT.
F. POSTS MUST BE VERTICAL PLUS OR MINUS 2 DEGREES IN EACH DIRECTION.
G. FENCING MUST BE GROUNDED IN ACCORDANCE WITH THE NATIONAL
ELECTRIC SAFETY CODE (NESC) - IEEE C2.
CONCRETE FOOTING NOTES:
A. CONCRETE FOR FENCE POSTS SHALL BE DESIGNED, MIXED AND PLACED IN ACCORDANCE
WITH ACI 318.
B. READY-MIX CONCRETE SHALL CONFORM TO ASTM C94 WITH MINIMUM COMPRESSIVE
STRENGTH OF 4,000 PSI AT 28 DAYS.
C. MINIMUM AGGREGATE SIZE SHALL BE 1-1/2 INCH.
D. CONCRETE SLUMP SHALL BE 2 TO 4 INCH AS MEASURED IN ACCORDANCE WITH ASTM C143.
E. FOOTINGS SHALL BE CYLINDRICAL IN SHAPE WITH THE TOP OF CONCRETE BEING 2 INCHES
ABOVE FINISHED GRADE, AS MEASURED AT THE POST. THE CONCRETE SHALL SLOPE AWAY
FROM THE POST WITH AT LEAST A ½ INCH DROP FROM THE CENTER TO THE EDGE OF THE
FOOTING.
F. THE DIMENSIONS PROVIDED FOR THE CONCRETE FOOTING ARE MINIMUMS AND ARE NOT
TO BE REDUCED.
4. STABILIZE ANY DISTURBED GROUND DUE TO PROPOSED CONC WORK WITH 4" TOP SOIL,
SEED AND MULCH.
SHEET KEYNOTES
8'4'01/4"=1'-0" 2'
CANOPY ROOF PLAN - NEW WORKA3
ELEVATION - WEST
ELEVATION - NORTH
ELEVATION - EAST
C1 C3
B1
CANOPY FLOOR PLAN - NEW WORKA1
ELEVATION - SOUTHB3
1/4"=1'-0"
1/4"=1'-0"
1/4"=1'-0"
1/4"=1'-0"
1/4"=1'-0"
1/4"=1'-0"
GENERAL SHEET NOTES
1. ALL WORK ON THIS SHEET IS FOR BID OPTION 2.
CONT. SHEET MTL.
FASCIA 2" W X 8" D
ON RAKE AND RIDGE SIDE, TYP
STANDING SEAM MTL ROOF;
PANEL SEAM HT MIN. 3";
PANEL WIDTH MAX. 8" WIDE
PRE-ENGINEERED
STRUCTURAL
STEEL
COLUMNS,
RAFTERS &
PURLINS
SHEET MTL.
INTEGRAL GUTTER;
MIN. SIZE 4" W X 6" H
DOWNSPOUT;
MIN. SIZE 2" W X 3" D
STANDING SEAM MTL ROOF;
PANEL SEAM HT MIN. 3";
PANEL WIDTH MAX. 8" WIDE
PRE-ENGINEERED
STRUCTURAL
STEEL
COLUMNS,
RAFTERS &
PURLINS
TOP RAIL
1'-6" DIA MIN
3' -0
" M
IN
S P
A C
E U
N D
E R
F A
B R
IC
2"
M A
X , T
Y P
1.66" OD PIPE
TRUSS ROD
CHAIN LINK FABRIC,
TYP
CHAIN LINK
BANDS, TYP
BRACE BAND
TERMINAL POST
CONCRETE
FOOTING,
TYPICAL
2'
6" M
IN
BARBED WIRE,
TYP
CROWN
CONCRETE
AT POST,
TYP
TOP RAIL
1.66" OD PIPE
TRUSS ROD
CHAIN LINK FABRIC,
TYP
CHAIN LINK
BANDS, TYP
BRACE BAND
TRUSS ROD, TYP
1'-0" DIA MIN
2' -6
" M
IN
3' -0
" M
IN
INTERMEDIATE POST
BARBED WIRE,
TYP
CROWN
CONCRETE
AT POST,
TYP
GATE POST
HINGE
CANE
BOLT
1'-0"
4" M
IN
LOCKING
DEVICE,
VIF
MATCH
EXIST.
INTERMEDIATE POST,
SEE DETAIL A2/A501E, TYP
BARBED WIRE, TYP
CONC.
CONC.
FOOTING,
SEE DETAIL
A2/A501E, TYP
DOUBLE GATE DETAILA3
C4C3 EAVE DETAIL GUTTER DETAIL
2'1'0 1"=1'-0"
1 1/2"=1'-0"
0 1' 1' 6"
1 1/2"=1'-0"
1 1/2"=1'-0"
1"=1'-0"
INTERMEDIATE POST DETAILA2 1"=1'-0"
TERMINAL POST DETAILA1 1"=1'-0"
GENERAL SHEET NOTES
1. ALL WORK ON THIS SHEET IS FOR BID OPTION 2.
EXISTING WALL (TYP)
D1
D3
D3
61'-6" 60'-8"
'-0
2'
-1 0"
2'-8" 2'-8"
2' -8
2'
-8
60'-6" 2'-8"
'-0
60'-8"
'-6
'-0
2' -8
2'
-8
'-6
'-0
A-501G A1
TYP
TYP
D2
TYP
D1 D1
AD101G
A2
AD101G
B2
AD101G
A1
AD101G
B1
D4
L1
L2
D1
D1
EXISTING BEAM
D5
TYP
SHEET KEYNOTES
D1. REMOVE EXIST. VINYL SOFFIT INCLUDING ASSOCIATED CHANNELS, VENT
SCREENS AND FASTENERS TO EXPOSE EXIST. VENTED WOOD SOFFIT.
D2. REMOVE EXIST. GUTTER, MTL. FASCIA COVER, DOWNSPOUTS AND SPLASH
BLOCKS.
D3. REMOVE LOUVER INCLUDING ANY ASSOCIATED FLASHING & SHIMS TO
EXPOSE STRUCTURAL JAMB, HEAD AND SILL STRUCTURE.
D4. DISCONNECT & REMOVE LIGHT FIXTURES. PROTECT EXISTING LIGHTING
CIRCUIT FOR REUSE.
D5. REMOVE EXIST. CORRODED MESH AT THE DUCT OPENING (SIZE ± 6" X 12").
D1 EXIST. WOOD SOFFIT WITH
VENTED SLOT TO REMAIND3
D4 D3
32'
1/16"=1'-0"
16'8'0
SOFFIT PLAN - DEMOLITIONA3
LOUVERA2
DAMAGED SOFFITB2LOUVERB1
SOFFITA1
LEGEND
X LOUVER TAG
NOT TO SCALE NOT TO SCALE
NOT TO SCALENOT TO SCALE
1/16"=1'-0"
DEMO EXIST. VINYL SOFFIT
±61'-6" ±60'-8"
±4 4'
-0
±2 '-1
0"
TYP
A-501G
A3
TYP
EXISTING INTERIOR WALL (NIC) TYP
±2'-8" ±2'-8"
±2 '-8
±2
'-8
±60'-6" ±2'-8"
±2 4'
-0
±60'-8"
±2 1'
-6
±2 4'
-0
±2 '-8
±2
'-8
±2 1'
-6 " 3
TYP
TYP
±4 4'
-0
A-501G B1
A-501G B1
L1
L2
A-101G B3
A-101G B1
A-101G C1
A-101G C3
TYP
DSDS
DSDS
DSDS
DS DS
DS DS
DSDS
TYP
±7 '-3
±1 5'
-0
TYP
EXIST. STANDING SEAM METAL
TYP
TYP
EXIST. LOUVER
EXIST. WINDOW, TYP
EXIST. DOOR , TYP
3 3
TYP
±7 '-3
±1 4'
-8
4 2
TYP
TYP
EXIST. DOOR, TYP
EXIST. WINDOW, TYP
EXIST. STANDING SEAM
METAL ROOFEXIST. LOUVER
±7 '-3
±1 4'
-8
TYP
TYP
TYP
EXIST. LOUVER
EXIST.
WINDOW,
TYP EXIST. DOOR, TYP
±7 '-3
±1 5'
-0
TYP
TYP
TYP
TYP
TYP
EXIST. WINDOW, TYP
EXIST. STANDING SEAM METAL ROOFEXIST. LOUVER
33 3
32' 1/16"=1'-0"
16'8'0
SHEET KEYNOTES
1. PROVIDE VENTED METAL SOFFIT PANEL SYSTEM OVER THE EXIST.
WOODEN SOFFIT SUBSTRATE IN ACCORDANCE TO THE FOLLOWING NOTES:
A. BASIS OF DESIGN PRODUCT: PROVIDE 0.032 IN THK ALUMINUM
V-GROOVE-PROFILE METAL SOFFIT PANEL, MODEL E-375 BY ENGLERT
OR APPROVED EQUAL.
A.1 METAL SOFFIT FINISH SHALL BE 3-COAT KYNAR. COLOR TO BE
SELECTED BY COR FROM MANUFACTURER'S FULL RANGE OF
AVAILABLE COLORS.
A.2 WARRANTY ON FINISHES: 20 YEARS
B. SUBMIT DELEGATED DESIGN FOR STRUCTURAL PERFORMANCE OF
METAL PANEL SYSTEM, INCLUDING ANALYSIS DATA SIGNED AND
SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER
RESPONSIBLE FOR THEIR PREPARATION. PROVIDE METAL PANEL
SYSTEMS CAPABLE OF WITHSTANDING THE EFFECTS OF THE
FOLLOWING LOADS, BASED ON TESTING ACCORDING TO ASTM E
1592:
B.1 WIND LOADS
ULTIMATE DESIGN WIND SPEED, VULT: 150 MPH
NOMINAL DESIGN WIND SPEED, VASD: 116 MPH
RISK CATEGORY: II
WIND EXPOSURE CATEGORY: D
INTERNAL PRESSURE COEFFICIENT: ±0.18
B.2 OTHER LOADS: SELF-WEIGHT OF THE METAL PANEL SYSTEM AND
FRAMING IT SUPPORTS
B.3 DEFLECTION LIMITS: FOR WIND LOADS, NO GREATER THAN 1/240.
C. SUBMIT PRODUCT DATA AND SHOP DRAWINGS FOR MTL SOFFIT SYSTEM.
2. PROVIDE SHEET MTL. GUTTER (STYLE-A, SIZE 6"X6") AND SHEET MTL.
FASCIA COVER; COLOR TO MATCH W/ EXISTING METAL. LIFT EXIST. EAVE
FLASHING TO ALLOW NEW GUTTER & FASCIA COVER INSTALLATIONS,
RESTORE EAVE FLASHING, SECURE AND SEAL WATERTIGHT.
3. PROVIDE DOWNSPOUT (± 4" W X 4" D) W/ PRECAST CONC SPLASH BLOCK
(SIZE 12" X 24") AT THE SPACING NOT TO EXCEED 40 FEET; DOWNSPOUT
COLOR TO MATCH W/ EXISTING. FIELD VERIFY DOWNSPOUT LOCATION TO
CLEAR ANY WALL OPENINGS.
4. PROVIDE WIND DRIVEN RAIN RESISTANT STATIONARY LOUVER. SEE
LOUVER SCHEDULE ON DRAWING A-501G.
5. PROVIDE 6" ROUND LED RECESSED DOWNLIGHT 3500 K COLOR
TEMPERATURE, 2000 LUMEN WET LOCATION LISTED AT ALL ORIGINAL
LOCATIONS, FIELD VERIFY. MATCH EXIST. FIXTURE FINISH. UTILIZE
EXISTING LIGHTING CIRCUIT.
6. REMOVE EXIST. ABANDONED FOUR (4) WALL ANCHORS (± 1-INCH DIA.) AND
PATCH HOLES IN THE WALL WITH BACKER ROD & SEALANT. INVESTIGATE
ENTIRE EXTERIOR WALLS FOR ANY OTHER HOLES AND PATCH W/ BACKER
ROD & SEALANT.
ESTIMATED QUANTITY: HOLE SURFACE AREA = ± 50 SQ. IN.
7. SEAL GAP (± 1/4 INCH WIDE) AROUND THE PIPE PENETRATIONS WITH
BACKER ROD AND SEALANT. INVESTIGATE ENTIRE EXTERIOR WALLS FOR
ANY OTHER PENETRATIONS WITH GAP AND PATCH WITH BACKER ROD AND
SEALANT.
ESTIMATED QUANTITY: GAP LENGTH = ± 5 LF
8. UNIT PRICE NO. 6: REPAIR CRACKS 1/32-INCH TO 1/8-INCH WIDE IN STUCCO
AS PER THE FOLLOWING METHOD:
A. REMOVE ALL LOOSE MATERIAL AND CLEAN THE CRACK.
B. APPLY COMPATIBLE BRUSH GRADE PATCH COMPOUND DIRECTLY OVER
THE CRACK AND FEATHER OUT A MINIMUM OF 4-INCH ON EACH SIDE.
BASIS OF DESIGN PRODUCT: 5100 PLASTIFLEX® ELASTOMERIC
ADHESIVE CAULK BY SCOTT PAINT.
INVESTIGATE ENTIRE EXTERIOR WALLS FOR ALL SUCH CRACK LOCATIONS
AND REPAIR AS ABOVE.
ESTIMATED QUANTITY: CRACK LENGTH = ± 200 LF.
9. UNIT PRICE NO. 7: REPAIR CRACKS 1/8-INCH TO 1/4-INCH WIDE IN STUCCO
AS PER THE FOLLOWING METHOD:
A. GRIND OUT CRACK TO A MIN 1/4-INCH WIDE BY 1/4 IN DEEP GROOVE.
B. REMOVE ALL LOOSE MATERIAL AND CLEAN THE CRACK.
C. FILL GROOVE WITH COMPATIBLE KNIFE GRADE PATCH COMPOUND.
D. BRIDGE CRACK WITH COMPATIBLE BRUSH GRADE PATCH COMPOUND.
APPLY AT APPROXIMATELY 1/4-INCH THICKNESS OVER THE CRACK AND
FEATHER OUT A MINIMUM OF 4-INCH ON EACH SIDE..
BASIS OF DESIGN PRODUCT: 5200 PLASTIFLEX® ELASTOMERIC PATCHING
COMPOUND BY SCOTT PAINT.
INVESTIGATE ENTIRE EXTERIOR WALLS FOR ALL SUCH CRACK LOCATIONS
AND REPAIR AS ABOVE.
ESTIMATED QUANTITY: CRACK LENGTH = ± 100 LF
10. REMOVE EXIST. DETERIORATED SEALANT AND ANY LOOSE MATERIALS
FROM THE VERTICAL JOINTS (± 1/4" WIDE) AT ALL EXTERIOR WALL TO WALL
CORNERS. CLEAN THE JOINT, PRIME JOINT EDGES AND PROVIDE BACKER
ROD AND SEALANT.
ESTIMATED QUANTITY: JOINT LENGTH = ± 40 LF
11. UPON COMPLETION OF MISC. WALL REPAIR AS AS PER NOTES #6 TO #10
ABOVE, CLEAN ENTIRE WALL SURFACE TO REMOVE ALL CHALK DIRT, DUST,
LOOSE COATINGS AND OTHER FOREIGN MATERIALS. PREPARE SURFACE
AND PROVIDE COMPATIBLE PRIMER AND WATERPROOF ELASTOMERIC
COATING OVER THE ENTIRE EXTERIOR WALL.
BASIS OF DESIGN PRODUCT: WEATHERPRIME & WEATHERLASTIC SMOOTH
COATING BY DRYVIT.
12. PROVIDE ALUMINUM LOUVERED GRILLE (SIZE ± 6"X12" VIF) AT EXIST. DUCT
OPENING IN THE SOFFIT. REWORK DUCT FLANGE AS PER MANUFACTURER
RECOMMENDATION. BASIS OF DESIGN: PROVIDE 350 FL BY TITUS.
±40'-0"
±40'-2"
SOFFIT PLAN - NEW WORKA1
WEST ELEVATIONB3NORTH ELEVATIONB1
SOUTH ELEVATIONC1 EAST ELEVATIONC3
LEGEND
X
WATERPROOF ELASTOMERIC
COATING OVER EXIST. STUCCO
METAL SOFFIT
LOUVER TAG
GENERAL SHEET NOTES
1. CONTRACTOR SHALL INSPECT THE BUILDING FACADES TO CONFIRM THE
TYPES AND LOCATIONS OF THE REPAIR WORK INDICATED IN THE PLAN AND
ELEVATIONS. ANY DISCREPANCIES AND DIFFERING WORK DISCOVERED
SHALL BE BROUGHT TO ATTENTION OF THE OWNER PRIOR TO THE
COMMENCEMENT OF THE WORK.
2. CONTRACTOR SHALL INSPECT THE BUILDING FACADE TO CONFIRM THE
ESTIMATED QUANTITIES PROVIDED BELOW IN NOTE #6 TO NOTE #10. ANY
DISCREPANCIES SHALL BE BROUGHT TO ATTENTION OF THE OWNER PRIOR
TO THE COMMENCEMENT OF THE WORK.
3. PROVIDE BASIS OF DESIGN PRODUCT OR APPROVED EQUAL W/
MANUFATURER'S STANDARD WARRANTY UNO.
1/16"=1'-0" 1/16"=1'-0"
1/16"=1'-0"1/16"=1'-0"
1/16"=1'-0"
DS DOWNSPOUT W/ SPLASH BLOCK
GENERAL SHEET NOTES
1. CONTRACTOR SHALL INSPECT THE BUILDING FACADES TO CONFIRM THE
TYPES AND LOCATIONS OF THE REPAIR WORK INDICATED IN THE PLAN AND
ELEVATIONS. ANY DISCREPANCIES AND DIFFERING WORK DISCOVERED
SHALL BE BROUGHT TO ATTENTION OF THE C.O.R. PRIOR TO THE
COMMENCEMENT OF THE WORK.
2. PROVIDE BASIS OF DESIGN PRODUCT OR APPROVED EQUAL W/
MANUFATURER'S STANDARD WARRANTY UNO.
3. FOLLOWING WORK SHALL BE ACCOMPLISHED UNDER UNIT PRICING:
3.1. UNIT PRICE NO. 2: REPLACE DAMAGED DIMENSIONAL LUMBER:
REMOVE DAMAGED DIMENSIONAL LUMBER WHICH IS INDICATED TO
REMAIN, AND FOUND TO BE DETERIORATED UPON UNCOVERING DURING
DEMOLITION. REPLACE WITH NEW DIMENSIONAL LUMBER TO MATCH
EXIST. THICKNESS/SIZE.
ESTIMATED QUANTITY: INCLUDE 60 BOARD FOOT OF DIMENSIONAL
LUMBER REPLACEMENT IN THE BASE BID.
3.2. UNIT PRICE NO. 6: REPAIR CRACKS 1/32-INCH TO 1/8-INCH WIDE IN STUCCO:
SEE KEY NOTE # 8 ON SHEET FOR REPAIR METHOD AND ESTIMATED
QUANTITY.
3.3. UNIT PRICE NO. 7: REPAIR CRACKS 1/32-INCH TO 1/8-INCH WIDE IN STUCCO:
SEE KEY NOTE # 9 ON SHEET FOR REPAIR METHOD AND ESTIMATED
QUANTITY.
REMOVE EXIST. VINYL SOFFIT
INCLUDING CHANNELS, AND
FASTENERS TO EXPOSE WOOD
SOFFIT
EXIST STANDING SEAM METAL ROOF TO REMAIN, TYP
REMOVE EXIST SHEET
METAL FASCIA COVER
EXIST. WOOD SOFFIT TO
REMAIN
REMOVE EXIST. MTL CHANNEL AND
ABANDONED SCREEN (TYP)
EXIST MASONRY WALL W/ STUCCO
FINISH (TYP)
REMOVE EXIST. GUTTER
LIFT EAVE FLASHING TO ALLOW
GUTTER & FASCIA INSTALLATION
EXIST. FASCIA WOOD BOARD
TO REMAIN
REMOVE EXIST. DOWNSPOUT
AND SPLASH BLOCK, TYP
EXIST. EXTERIOR GRADE, TYP
EXIST. WALL BEHIND, TYP
VENTED METAL SOFFIT
INCLUDING SUPPORT
CHANNELS, FURRINGS &
FASTENERS
EXIST. STANDING SEAM METAL ROOF, TYP
EXIST. VENTED WOOD SOFFIT,
FIELD VERIFY, RE-FASTEN /
SECURE TO EXIST. ROOF
JOISTS IF LOOSE, TYP
PROVIDE SEALANT (TYP)
EXIST MASONRY WALL W/ STUCCO
FINISH (TYP)
PROVIDE GUTTERS
SMACNA STYLE A
(SIZE 6"X6")
SHEET METAL FASCIA
COVER
PATCH & FINISH EXIST. STUCCO IF
DAMAGED DUE TO SOFFIT
REPLACEMENT WORK; MATCH W/
EXTERIOR STUCCO FINISH
PROVIDE CONT. SOFFIT
J-CHANNELS W/ MTL FURRINGS
AT THE SOFFIT PERIMETER (TYP)
PROVIDE
INTERMEDIATE
FURRING TO SUPPORT
THE SOFFIT PANELS AT
THE CENTER (TYP)
PROVIDE CONT. SOFFIT
J-CHANNELS W/ MTL FURRINGS
AT THE SOFFIT PERIMETER (TYP)
EXIST. FASCIA WOOD BOARD
TYP
4" THK PLYWOOD ATTACHED TO
EXIST. SOFFIT FRAMING / JOISTS
+/- 6"
" V
IF
SHEET MTL DOWNSPOUT
SIZE(4" X4") SECURED TO THE
WALL, TYP
EXIST. WALL BEHIND, TYP
PRECAST CONC SPLASH
BLOCK (SIZE 12" X 24"),
PROVIDE UNDER EACH
DOWNSPOUT, TYP
EXIST. WALL W/ STUCCO
FINISH, TYP; FIELD VERIFY
EXIST. HEAD, JAMB &
SILL CONSTRUCTION; PATCH
& FINISH ANY DAMAGE
TO THE STUCCO WALL DUE TO THE
LOUVER REPLACEMENT TO MATCH W/
EXIST. STUCCO FINISH; REPLACE
ANY EXIST. DETERIORATED WOOD
DISCOVERED AT HEAD, JAMB OR SILL
UNDER THE UNIT PRICE #2, TYP
FLANGE MOUNT WIND DRIVEN
RAIN RESISTANT STATIONARY
LOUVER; BLADE PROFILE AS
PER SCHEDULED PRODUCT
FASTENERS, AS PER
MANUFACTURER'S
REQUIREMENT, TYP
SEALANT, ALL AROUND
PERIMETER, TYP
RECONNECT TO EXIST.
MECH. DUCT / FAN, VIF
BIRD-SCREEN
1 1/2"=1'-0" 0 1' 1' 6"
SOFFIT DETAIL - NEW WORKA3
SOFFIT DETAIL - DEMOLITIONA1
LOUVER SCHEDULE
LOUVER TYPE WIDTH HEIGHT REMARKS
L1
L2
± 3'-6" VIF ± 3'-6" VIF
± 4'-0" VIF ± 2'-6" VIF
1, 2, 3, 4
LOUVER DETAIL NEW WORKB1
1 1/2"=1'-0"1 1/2"=1'-0"
1 1/2"=1'-0"
MATERIAL FINISH
MANUFACTURER MODEL
FREE AREA FRAME
AL KYNAR RUSKIN EME420MD 40% MIN. INTEGRAL FLANGE
REMARKS:
1. PROVIDE 20 YEAR FINISH WARRANTY.
2. COLOR SHALL MATCH EXISTING.
3. LOUVER SHALL BE MIAMI-DADE COUNTY APPROVED FOR HIGH WINDLOAD (±120 PSF) AND MISSILE IMPACT
RESISTANCE.
4. SUBMIT LOUVER PRODUCT DATA AND SHOP DRAWING.
1, 2, 3, 4AL KYNAR RUSKIN EME420MD 40% MIN. INTEGRAL FLANGE
BASIS OF DESIGN
10X8
12X10
10X8
10X8
16X8
14X12
14X12
12X6 12X6
14X12
10X8
10X8
10X8
30X12
12X8
12X8
16X8 12X8
8X8
20X8 16X12
24X1210X6
10X8
8X8
8X8
10X810X8
16X8
10X8
12X4 12X4
14X12
24X12
16X10
12X8 10X8
10X8
12X8
10X8
12X8
8X8
16X12 16X8
8X8
8X8
12X8
16X10
± 24'-0"
3' -0
± 24'-0"
± 29'-4" ± 27'-4"
± 27'-4"
'-4
± 29'-4"
D6
TYP
D7
D7
TYP
TYP
D7
TYP
D7
TYP
EXIST. EXT. DOOR (TYP)
EXIST. EXT. WALL (TYP)
EXIST. WINDOW (TYP)
EXIST. SOFFIT (TYP)
EXIST. MECHANICAL DUCT INSIDE
THE ATTIC (TYP)
EXIST. DUCT SIZE IN INCH (TYP)
EXIST. SMOKE
BARRIER TO THE
UNDERSIDE OF
THE PLYWOD ROOF
DECK (TYP)
EXIST. ATTIC WOOD JOISTS
AT 24" O.C. (TYP)
EXIST. MECH
EQUIPMENT (TYP)
± 3'-4"
± 3'-4"
'-8
'-8
± 3'-4"
± 3'-4" ± 3'-4"
ATTIC ACCESS
THROUGH CEILING
(± 24" X 24" VIF)
± 31'-8"
4' -4
± 26'-0" ± 34'-6"
6' -0
'-8
± 35'-0"
1' -4
9' -0
± 25'-0"
TYP
P
V
V
GN
EF
EF
D1
L
L
L
L
L
L
L L
PP
P
V
D5
D4
TYP
TYP
D2
D2
D2
D2
± 30'-8"
EXIST. EXT. WALL
BELOW (TYP)
EXIST.
ROOF
SLOPE
± 4:12 VIF
(TYP)
AD101H
C1
DS
D3
D1
D3
AD101H
C2
TYP
A-501H
C1
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
D1. REMOVE EXIST. ASPHALT SHINGLES INCLUDING UNDERLAYMENT, ASSOCIATED FLASHING
AND LIGHTNING PROTECTION DOWN TO THE EXIST. PLYWOOD DECK TO REMAIN.
D2. REMOVE EXIST. GUTTER INCLUDING DOWNSPOUTS, SPLASH BLOCKS & FASCIA METAL COVER.
D3. REMOVE EXIST. CORRODED GOOSENECK AND ROOF VENT. PROTECT DUCT OPENING TO
RECEIVE NEW GOOSENECK AND VENTS.
D4. EXIST. VENT PIPE SHALL REMAIN; REMOVE FLASHING.
D5. DISCONNECT, REMOVE AND SALVAGE EXIST. EXHAUST FAN FOR REUSE. PROTECT EXISTING
CIRCUIT AND DUCT / OPENING FOR REUSE.
D6. REMOVE EXIST. BATT INSULATION COMPLETELY FROM THE ENTIRE ATTIC AREA. WORK
CAREFULLY IN THE ATTIC AREA AND PROTECT EXIST. CONSTRUCTION TO REMAIN INCLUDING
BUT NOT LIMITED TO THE GYP BOARD CEILING, SMOKE BARRIER, MECHANICAL DUCTS,
PIPING, CONDUITS AND LIGHTING:
A. DURING THE REMOVAL OF INSULATION, INTERIOR SPACES UNDER THE CEILING SHALL BE
PROTECTED FROM ANY INSULATION DUST. AFTER INSULATION IS REMOVED, VACUUM
ENTIRE ATTIC AREA USING HEPA FILTERED INDUSTRIAL VACUUM TO REMOVE ANY
INSULATION DUST FROM THE ATTIC.
B. INSULATION SHALL BE REMOVED DIRECTLY TO THE OUTSIDE THROUGH THE ROOF;
REMOVE EXIST. PLYWOOD ROOF DECK FROM JOIST TO JOIST ONLY AS REQUIRED TO
REMOVE ATTIC INSULATION; CLOSE THE OPENING WITH NEW PLYWOOD SHEATHING IN
THICKNESS TO MATCH EXISTING (5/8" VIF).
D7. EXIST. METAL SOFFIT SHALL REMAIN. PROTECT EXIST. METAL SOFFIT AND SECURE IN
PLACE DURING THE ROOF REPLACEMENT WORK.
SHEET KEYNOTESGENERAL SHEET NOTES
1. MECHANICAL DUCT LAYOUT AS SHOWN IN THE ATTIC PLAN IS BASED ON THE
RECORD DRAWINGS AND INCLUDED HERE TO SHOW AVAILABLE SPACE INSIDE
THE ATTIC FOR ACCOMPLISHING THE PROPOSED WORK. ACTUAL CONDITION
INSIDE THE ATTIC MAY VARY; FIELD VERIFY.
1/8"=1'-0" 16'8'4'0
ROOF PLAN - DEMOA1 ATTIC PLAN - BATT INSULATION DEMOA3
EXHAUST FANC1 ROOF & PIPE VENTC2
LEGEND
ASPHALT SHINGLES
METAL SOFFIT
BATT INSULATION
D4
1/8"=1'-0"
NOT TO SCALE NOT TO SCALE
1/8"=1'-0"
GOOSE NECK
ROOF VENT
VENT PIPE
EXHAUST FAN
DOWNSPOUT W/ SPLASH BLOCK
LIGHTNING PROTECTION
/ GN
/ V
/ P
/ EF
/ DS
/ L
D5 D3
±31'-8"
±7 4'
-4
±56'-8" ±34'-6"
±1 6'
-0
±1
'-8
±35'-0"
±6 1'
-4
±4 9'
-0
±25'-0"
TYP
A-201H B1
A-201H A1
A-201H C1
A-201H B2
P
V
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
V
V
GN
EF
EF
PP
P
V
EXIST. EXT. WALL
BELOW (TYP)
EXIST.
ROOF
SLOPE
± 4:12 VIF
(TYP) TYP
A-102H A3
S
LO
P E
D O
W N
SLOPE
DOWN
SLOPE
DOWN
SLOPE
DOWN
S
LO
P E
D O
W
N TYP
A-501H C3
TYP
A-501H
B3
TYP
A-501H
B1
TYP
A-501H
B1
TYP
A-501H
B1
TYP
A-501H
B2
TYP
A-501H
A1
TYP
A-501H
A1
TYP
A-501H
A1
TYP
A-501H
A1
TYP
A-501H
B3
TYP
A-501H
C3
TYP
A-501H C3
EXPANSION
JOINT, TYP
EXPANSION
JOINT, TYP
TYP
A-501H
A2
TYP
A-501H
A2
EXIST. SMOKE BARRIER TO THE
UNDERSIDE OF ROOF DECK
EXIST. MECHANICAL
DUCT, SEE
A3/AD101H FOR
EXIST. DUCT
LAYOUT, VIF
GYP BOARD CEILING
TYP
9'
-0 " V
IF
TR
U S
S B
E A
R
IN
G
± 4:12 ± 4:12
TYP
TYP
TYP
TYP
1/8"=1'-0"
16'8'4'0
TYP SECTION
ROOF PLAN
A3
A1
1. PROVIDE STANDING SEAM METAL ROOFING SYSTEM INCLUDING UNDERLAYMENT, AND
ASSOCIATED FLASHING. SEE ROOF DETAILS ON SHEET A-501H.
2. PROVIDE SHEET MTL. GUTTER (STYLE-A, SIZE 6"X6") AND SHEET MTL. FASCIA COVER;
COLOR TO MATCH W/ EXISTING METAL. LIFT EXIST. EAVE FLASHING TO ALLOW NEW
GUTTER & FASCIA COVER INSTALLATIONS, RESTORE EAVE FLASHING, SECURE AND SEAL
WATERTIGHT.
3. PROVIDE DOWNSPOUT (± 4" W X 4" D) W/ PRECAST CONC SPLASH BLOCK (SIZE 12" X 24")
AT THE SPACING NOT TO EXCEED 40 FEET; DOWNSPOUT COLOR TO MATCH W/ EXISTING.
FIELD VERIFY DOWNSPOUT LOCATION TO CLEAR ANY WALL OPENINGS.
4. PROVIDE GALVANIZED STL GOOSENECK AND ROOF VENTS OVER PRE-MANUFACTURED
SHEET METAL CURB AT THE EXIST. GOOSENECK / ROOF VENT LOCATIONS. UTILIZE EXIST.
DUCT (SIZE ± 8" X 8" VIF), EXTEND / ADJUST EXIST. DUCT AS REQUIRED TO
ACCOMMODATE NEW CURB HT.
5. REINSTALL THE EXIST. SALVAGED EXHAUST FAN OVER PRE-MANUFACTURED SHEET
METAL CURB AT THE EXIST. EXHAUST FAN LOCATION. UTILIZE EXISTING EXIST. DUCT
(SIZE ± 10" X 10" VIF) AND FAN CIRCUIT; EXTEND OR ADJUST DUCT AND CIRCUIT AS
REQUIRED TO ACCOMMODATE NEW CURB HT.
6. CLOSE RIDGE, SOFFIT, DORMER VENTS AND PROVIDE R-25 OPEN CELL SPRAY FOAM
INSULATION AT THE UNDERSIDE OF THE ENTIRE ROOF DECK AND WALL ABOVE THE
CEILING TO CREATE UN-VENTED ATTIC W/ CONT. THERMAL ENVELOP AT THE UNDERSIDE
OF THE ROOF DECK. WORK CAREFULLY INSIDE THE ATTIC AND PROTECT EXIST. CEILING,
MECHANICAL DUCTS, UTILITIES AND OTHER CONSTRUCTION TO REMAIN.
7. PROVIDE CONT. EXPANSION JOINT IN MTL. ROOF, GUTTER AND FASCIA COVER AT THE
EXIST. ± 1-IN WIDE EXPANSION JOINT LOCATION. COMPLY W/ SMACNA STANDARD FOR
INSTALLING EXPANSION JOINT IN SHEET METAL.
SHEET KEYNOTES
1/8"=1'-0"
LEGEND
GOOSE NECK
ROOF VENT
VENT PIPE
EXHAUST FAN
DOWNSPOUT W/ SPLASH BLOCK
/ GN
/ V
/ P
/ EF
/ DS
1/8"=1'-0"
STANDING SEAM METAL ROOF
GENERAL SHEET NOTES
1. FOLLOWING WORK SHALL BE ACCOMPLISHED UNDER UNIT PRICING:
1.1. UNIT PRICE NO. 1: REMOVE EXISTING PLYWOOD DECKING THAT IS FOUND TO
BE DETERIORATED DURING CONSTRUCTION TO THE CLOSEST RAFTER
CENTERLINE ON EITHER SIDE OF THE DAMAGED AREA. PROVIDE PLYWOOD
ROOF SHEATHING TO MATCH DECK THICKNESS (5/8" THICK VIF), ATTACH TO
WOOD FRAMING AS PER EXPOSED CONDITIONS.
ESTIMATED QUANTITY: INCLUDE 600 SF OF PLYWOOD SHEATHING
REPLACEMENT IN THE BASE BID.
1.2. UNIT PRICE NO. 2: REPLACE DAMAGED DIMENSIONAL LUMBER:
REMOVE EXISTING DIMENSIONAL LUMBER THAT IS FOUND TO BE
DETERIORATED DURING CONSTRUCTION. REPLACE WITH NEW DIMENSIONAL
LUMBER TO MATCH EXIST. THICKNESS/SIZE.
ESTIMATED QUANTITY: INCLUDE 60 BOARD FOOT OF DIMENSIONAL
LUMBER REPLACEMENT IN THE BASE BID.
±7 '-0
D2 8
STANDING SEAM MTL ROOF, TYP
±3
'-8
±18'-0"
±1 3'
-9
EXIST.
WINDOW,
TYP
EXIST. STOREFRONT, TYP
EXPANSION JOINT
TYP
TYP
CONTROL JOINT, TYP
DOWNSPOUT & SPLASH BLOCK, TYP
GUTTER, TYP
±7 '-0
7 410
EXIST.
WINDOW,
TYP
EXIST.
WINDOW,
TYP
STANDING SEAM
MTL ROOF, TYPTYPTYP
TYP
TYP
CONTROL JOINT, TYP
DOWNSPOUT &
SPLASH BLOCK, TYP
GUTTER, TYP
±7 '-0
6 5
6 56 5
EXIST. LOUVER
± 8'-0"
EXIST. LOUVER
± 8'-0"
EXIST. DOOR, TYP EXIST. DOOR, TYP
STANDING SEAM MTL ROOF, TYP
TYP
CONTROL JOINT, TYP
TYP TYP
TYP
TYP
TYPTYPTYPTYPTYPTYPTYP
DOWNSPOUT &
SPLASH BLOCK, TYP
GUTTER, TYP
±7 '-0
"±1 2'
-2
957 7
EXIST. LOUVER
± 8'-0"
EXIST. DOOR, TYP
EXIST. LOUVER
EXIST.
WINDOW,
TYP
STANDING SEAM MTL ROOF, TYP
EXPANSION JOINT
TYP
TYP TYP
TYP
TYP
CONTROL JOINT, TYP
GUTTER, TYP
±1 8'
-0
±27'-4"
12 D1 A-201H
C3
TYP
A501H A3
D2A-201H B3
8'
-6 " V
IF
3'
-0 " V
IF
± 5' - 0" VIF
D1
EXIST. CEILING, TYP
EXIST. WINDOW, TYP
SHEET KEYNOTES
D1. REMOVE EXISTING WATER DAMAGED SECTION OF GYPSUM WALL BOARD
INCUDING FURRING, RIGID INSULATION AND VINYL BASE. SEE ELEC. FOR
HANDLING OF EXIST. CONDUIT AT THE DAMAGED AREA.
D2. REMOVE EXIST. WATER DAMAGED STUCCO DOWN TO THE CMU TO REMAIN.
INTERIOR DRYWALL REPAIR NOTES:
1. PROVIDE 5/8" THK GYPSUM WALL BOARD INCLUDING Z-FURRING, RIGID
INSULATION AND VINYL BASE.
2. PREPARE SURFACE AND PAINT THE ENTIRE WALL FROM CORNER TO
CORNER TO MATCH EXIST. COLOR AND FINISH.
3. SEE C1/E-101H FOR ELECTRICAL WORK REQ'D.
EXTERIOR STUCCO REPAIR NOTES
4. SEAL GAP (± 1/4 INCH WIDE) AROUND THE PIPE PENETRATIONS WITH
BACKER ROD AND SEALANT. INVESTIGATE ENTIRE EXTERIOR WALLS FOR
ANY OTHER PENETRATIONS WITH GAP AND PATCH WITH BACKER ROD AND
SEALANT.
ESTIMATED QUANTITY: GAP LENGTH = ± 5 LF
5. UNIT PRICE NO. 6: CRACKS 1/32-INCH TO 1/8-INCH WIDE IN STUCCO:
A. REMOVE ALL LOOSE MATERIAL AND CLEAN THE CRACK.
B. APPLY COMPATIBLE BRUSH GRADE PATCH COMPOUND DIRECTLY OVER
THE CRACK AND FEATHER OUT A MINIMUM OF 4-INCH ON EACH SIDE.
BASIS OF DESIGN PRODUCT: 5100 PLASTIFLEX® ELASTOMERIC
ADHESIVE CAULK BY SCOTT PAINT.
INVESTIGATE ENTIRE EXTERIOR WALLS FOR ALL SUCH CRACK LOCATIONS
AND REPAIR AS ABOVE.
ESTIMATED QUANTITY: CRACK LENGTH = ± 200 LF.
6. UNIT PRICE NO. 7: FOR CRACKS 1/8-INCH TO 1/4-INCH WIDE IN STUCCO:
A. GRIND OUT CRACK TO A MIN 1/4-INCH WIDE BY 1/4 IN DEEP GROOVE.
B. REMOVE ALL LOOSE MATERIAL AND CLEAN THE CRACK.
C. FILL GROOVE WITH COMPATIBLE KNIFE GRADE PATCH COMPOUND.
D. BRIDGE CRACK WITH COMPATIBLE BRUSH GRADE PATCH COMPOUND.
APPLY AT APPROXIMATELY 1/4-INCH THICKNESS OVER THE CRACK AND
FEATHER OUT A MINIMUM OF 4-INCH ON EACH SIDE.
BASIS OF DESIGN PRODUCT: 5200 PLASTIFLEX® ELASTOMERIC
PATCHING COMPOUND BY SCOTT PAINT.
INVESTIGATE ENTIRE EXTERIOR WALLS FOR ALL SUCH CRACK LOCATIONS
AND REPAIR AS ABOVE.
ESTIMATED QUANTITY: CRACK LENGTH = ± 75 LF
7. REMOVE EXIST. DETERIORATED SEALANT AND ANY LOOSE MATERIALS
FROM ALL EXTERIOR CORNERS(± 1/4" WIDE), CONTROL JOINTS (± 1/2" WIDE)
& EXPANSION JOINTS ( ±1" WIDE) . CLEAN THE JOINT, PRIME JOINT EDGES
AND PROVIDE BACKER ROD AND SEALANT.
ESTIMATED QUANTITY: JOINT LENGTH = ± 40 LF
8. PROVIDE STUCCO FINISH SYSTEM INCLUDING COMPATIBLE BONDING
AGENT AND FIBERGLASS REINFORCED CEMENT PLASTER IN THICKNESS
TO MATCH EXIST (± 1/2" VIF).
BASIS OF DESIGN PRODUCT: COMMERCIAL CEMENT PLASTER (CCP) 1 BY
DRYVIT.
9. REPAIR STUCCO SPALL AS PER THE FOLLOWING METHOD:
A. REMOVE LOOSE STUCCO DOWN TO THE CMU SUBSTRATE.
B. CLEAN AREA AND PATCH WITH COMPATIBLE BONDING AGENT AND
CEMENT PLASTER.
BASIS OF DESIGN PRODUCT: COMMERCIAL CEMENT PLASTER (CCP) 1 BY
DRYVIT.
ESTIMATED QUANTITY: STUCCO SPALL AREA = ± 6 SF
10. UPON COMPLETION OF MISC. WALL REPAIR AS AS PER NOTES #4 TO #10
ABOVE, CLEAN ENTIRE WALL SURFACE TO REMOVE ALL CHALK DIRT, DUST,
LOOSE COATINGS AND OTHER FOREIGN MATERIALS. PREPARE SURFACE
AND PROVIDE COMPATIBLE PRIMER AND WATERPROOF ELASTOMERIC
COATING OVER THE ENTIRE EXTERIOR WALL.
BASIS OF DESIGN PRODUCT: WEATHERPRIME & WEATHERLASTIC SMOOTH
COATING BY DRYVIT.
11. PROVIDE 0.05-IN THK PREFINISHED ALUMINUM SHEET MTL BLANK-OFF
PANEL AT ALL ATTIC LOUVERS PRIOR TO SPRAY FOAM APPLICATION INSIDE
THE CEILING SPACE. ATTACH BLANK-OFF PANEL TO THE LOUVER WITH
MANUFACTURER RECOMMENDED CLIPS AND FASTENERS. COLOR TO
MATCH EXIST. LOUVER.
1/8"=1'-0"
16'8'4'0
A1 NORTH ELEVATION
B2 SOUTH ELEVATION
B1 WEST ELEVATION
C1 EAST ELEVATION
DRYWALL REPAIR - PART PLANA3
DRYWALL REPAIR - ELEVATIONB3
D1
PHOTO- DRYWALL REPAIRC3
1/8"=1'-0"
1/8"=1'-0"
1/4"=1'-0"
1/8"=1'-0"
1/8"=1'-0"
8'4'0 2'
1/8"=1'-0"
1/4"=1'-0"
NOT TO SCALE
GENERAL SHEET NOTES
1. CONTRACTOR SHALL INSPECT THE BUILDING FACADES TO CONFIRM THE
TYPES AND LOCATIONS OF THE REPAIR WORK INDICATED IN THE PLAN
AND ELEVATIONS. ANY DISCREPANCIES AND DIFFERING WORK
DISCOVERED SHALL BE BROUGHT TO ATTENTION OF THE C.O.R. PRIOR TO
THE COMMENCEMENT OF THE WORK.
2. PROVIDE BASIS OF DESIGN PRODUCT OR APPROVED EQUAL W/
MANUFATURER'S STANDARD WARRANTY UNO.
3. FOLLOWING WORK SHALL BE ACCOMPLISHED UNDER UNIT PRICING:
3.1. UNIT PRICE NO. 6: REPAIR CRACKS 1/32-INCH TO 1/8-INCH WIDE IN
STUCCO: SEE KEY NOTE # 5 ON SHEET FOR REPAIR METHOD AND
ESTIMATED QUANTITY.
3.2. UNIT PRICE NO. 7: REPAIR CRACKS 1/32-INCH TO 1/8-INCH WIDE IN
STUCCO: SEE KEY NOTE # 6 ON SHEET FOR REPAIR METHOD AND
ESTIMATED QUANTITY.
EXIST. MTL SOFFIT TO REMAIN
REMOVE ASPHALT SHINGLES
INCLUDING UNDERLAYMENT
AND ASSOCIATED FLASHING TO
EXPOSE EXIST. PLYWOOD DECK TYP
REMOVE EXIST SHEET
METAL FASCIA COVER
EXIST MASONRY WALL W/ STUCCO
FINISH TO REMAIN (TYP)
REMOVE EXIST. GUTTER INCLUDING
DOWNSPOUTS AND SPLASH BLOCKS.
EXIST. MTL SOFFIT TO REMAIN,
FIELD VERIFY, RE-FASTEN /
SECURE TO EXIST. STRUC IF
LOOSE, TYP
PROVIDE SEALANT (TYP)
EXIST MASONRY WALL W/ STUCCO
FINISH (TYP)
PROVIDE GUTTERS
SMACNA STYLE A (SIZE
6"X6") & DOWNSPOUTS
(SIZE 4"X4"). RE-SECURE
EAVE FLASHING & SEAL
JOINTS
SHEET METAL FASCIA
COVER
REPAIR STUCCO AS SCHEDULED, TYP
PROVIDE 5/8" THK PLYWOOD
BETWEEN EXIST. ROOF JOISTS
ALL AROUND EAVE PERIMETER
TO CLOSE-OFF VENT, TYP
EXIST. FASCIA WOOD BOARD
R-25 SPRAY-FOAM INSULATION
EXIS…