CYPRESS (WLB 225B) DD FQ4 KAH 25R1 BLANK PRICING SCHEDULE.xls
XLS spreadsheet 152 KB Posted
- Solicitation number
- 70Z08525RIBCT0002
About this file
This is a comprehensive pricing schedule for the USCGC CYPRESS (WLB-225B) Drydock Availability for Fiscal Year 2025. The document contains a detailed line-item breakdown of 118 specific maintenance and repair tasks, each priced at $0.00, covering extensive ship systems including hull plating, propulsion components, tanks, ventilation, hydraulic systems, cathodic protection, and various preservation and inspection activities. The drydock is scheduled for performance starting around September 29, 2025, with a projected end date of January 5, 2026, and is being solicited by the US Coast Guard under solicitation number 70Z08525RIBCT0002.
The pricing schedule includes a cost estimate template with labor rate assumptions of $55 per hour, a 15% General & Administrative factor, and a 10% profit factor. The only line item with a specified price is the drydock itself at $149,250.00, with an estimated 1,600 labor hours. The procurement is structured as an unrestricted commercial items solicitation using FAR Part 12 and Part 13.5, with a NAICS code of 336611 (Ship Repair) and a small business size standard of 1,300 employees. The scope encompasses comprehensive ship repair and associated support work for the USCGC CYPRESS buoy tender, potentially including items not explicitly listed in the definitive item list.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CYPRESS DD FY 25 Work Item - Blank Revised.xlsx | XLSX spreadsheet | |
| CYPRESS (WLB 225B) DD FQ4 KAH 25R3.pdf | ||
| A00004.pdf | ||
| Clarifications for Solicitation 70Z08525RIBCT0002.docx | DOCX document | |
| A00003.pdf | ||
| CYPRESS (WLB 225B) DD FQ4 KAH 25R2.pdf | ||
| A00002.pdf | ||
| CYPRESS (WLB 225B) DD FQ4 KAH SPECS 25R1.pdf | ||
| 70Z08525RIBCT0002 CGC CYPRESS SOLICITATION.pdf | ||
| A00001.pdf | ||
| Clarifications for Solicitation 70Z08525QIBCT0006.docx | DOCX document | |
| Attachment 1 - CYPRESS DD FY 25 Work Item - Blank.xls | XLS spreadsheet | |
| Attachment 2 - USCGC CYPRESS DD FY25 - SPECIFICATION.pdf | ||
| Attachment 3 - Past Performance Information Form.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOS&S
| PRICING SCHEDULE: | APM | ||||
| USCGC CYPRESS (WLB-225B) DRYDOCK AVAILABILITY FY2025 | Date Spec Due | ||||
| Date Est Due | |||||
| ITEM | DESCRIPTION | UNIT PRICE | UNIT | QTY | EXTENDED PRICE |
| D-001 | Fire Prevention Requirements | $0.00 | NSP | 1 | $0.00 |
| D-002 | Hull Plating, U/W Body, Inspect | $0.00 | JOB | 1 | $0.00 |
| D-003 | Hull Plating, U/W Body, Ultrasonic Testing | $0.00 | JOB | 1 | $0.00 |
| D-004 | Hull Plating, Freeboard, Ultrasonic Testing | $0.00 | JOB | 1 | $0.00 |
| D-005 | U/W Body, Preserve, Partial, Condition A | $0.00 | JOB | 1 | $0.00 |
| O-006 | U/W Body, Preserve, Partial, Condition B | $0.00 | JOB | 1 | $0.00 |
| O-007 | U/W Body, Preserve, Partial, Condition C | $0.00 | JOB | 1 | $0.00 |
| D-008 | Hull Plating Freeboard, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| D-009 | Appendages, U/W, Leak Test | $0.00 | JOB | 1 | $0.00 |
| D-010 | Propulsion Shaft Fairwaters And Rope Guards, Inspect | $0.00 | JOB | 1 | $0.00 |
| D-011 | Appendages, U/W, Internal, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-012 | Chain Lockers, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-013 | Voids, Non-Accessible, Leak Test | $0.00 | JOB | 1 | $0.00 |
| D-014 | Voids, Non-Accessible, Internal Surfaces, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-015 | Tanks, MP Fuel Service, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-016 | Tanks, Potable Water, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-017 | Tanks, Ballast, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-018 | Voids, Accessible, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-019 | Tanks, Dirty Oil and Waste, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-020 | Hydraulically Operated Cargo Hatch, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-021 | Propulsion Shaft Seals, Mechanical Overhaul And Inflatable Renewal | $0.00 | JOB | 1 | $0.00 |
| D-022 | Propulsion Shaft Seals, Bulkhead, Overhaul | $0.00 | JOB | 1 | $0.00 |
| D-023 | Strain Gage Alignment, Check | $0.00 | JOB | 1 | $0.00 |
| D-024 | Propulsion Shaft Bearings, External, Check Clearances | $0.00 | JOB | 1 | $0.00 |
| O-025 | Propulsion Shaft Bearing, Stave Renewal | $0.00 | JOB | 1 | $0.00 |
| D-026 | Controllable Pitch Propellers, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-027 | Controllable Pitch Propeller, System Maintenance, Perform | $0.00 | JOB | 1 | $0.00 |
| D-028 | Controllable Pitch Propeller Hub, General Maintenance with EAL, Perform | $0.00 | JOB | 1 | $0.00 |
| D-029 | Main Reduction Gear, Shaft End NDT | $0.00 | JOB | 1 | $0.00 |
| D-030 | Controllable Pitch Propellers, Remove and Reinstall | $0.00 | JOB | 1 | $0.00 |
| D-031 | Sea Water System Piping, Clean and Flush | $0.00 | JOB | 1 | $0.00 |
| D-032 | Heat Exchangers, Clean, Inspect And Hydro | $0.00 | JOB | 1 | $0.00 |
| D-033 | Main Diesel Engine, MDE, Exhaust Piping, Commercial Clean | $0.00 | JOB | 1 | $0.00 |
| D-034 | Ship Service Diesel Generator, SSDG, Exhaust Piping, Commercial Clean | $0.00 | JOB | 1 | $0.00 |
| D-035 | Emergency Diesel Generator, Clean & Inspect | $0.00 | JOB | 1 | $0.00 |
| D-036 | Fathometer Transducer, General Maintenance | $0.00 | JOB | 1 | $0.00 |
| D-037 | Vent Ducts, Engine And Motor Room, All, Commercial Cleaning | $0.00 | JOB | 1 | $0.00 |
| D-038 | Vent Ducts, Galley and Pantry Room, All, Commercial Cleaning | $0.00 | JOB | 1 | $0.00 |
| D-039 | Vent Ducts, Laundry Exhaust, Commercial Cleaning | $0.00 | JOB | 1 | $0.00 |
| D-040 | Vent Ducts, All Other, Commercial Cleaning | $0.00 | JOB | 1 | $0.00 |
| D-041 | Sea Valves and Waster Pieces, Overhaul Or Renew | $0.00 | JOB | 1 | $0.00 |
| D-042 | Sea Strainers, All Sizes, Renew | $0.00 | JOB | 1 | $0.00 |
| D-043 | Sea Strainers, Duplex, All Sizes, Overhaul | $0.00 | JOB | 1 | $0.00 |
| D-044 | Sea Strainers, Simplex, All Sizes, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-045 | Sea Bay, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| O-046 | Sea Bay, Preserve 100% | $0.00 | JOB | 1 | $0.00 |
| D-047 | Potable Water Pneumatic Tanks, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-048 | Compressed Air Receivers and System Valves, All, Clean, Inspect, Hydro and Lift | $0.00 | JOB | 1 | $0.00 |
| D-049 | Rudders, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| D-050 | Rudder Stock Bearings, Check Clearances | $0.00 | JOB | 1 | $0.00 |
| D-051 | Rudder, Inspect And Repair | $0.00 | JOB | 1 | $0.00 |
| D-052 | Rudder and Rudder Stock, Remove and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-053 | Rudder Bearings, Renewal | $0.00 | JOB | 1 | $0.00 |
| D-054 | Thruster Units, Overhaul Fluid Change to EAL | $0.00 | JOB | 1 | $0.00 |
| D-055 | Hull Fittings (Weight Handling Rigging Hardware), Inspect and Test | $0.00 | JOB | 1 | $0.00 |
| D-056 | Hydraulic Chain Stoppers, Inspect And Service | $0.00 | JOB | 1 | $0.00 |
| D-057 | Crossdeck Winches, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-058 | Hydraulic Inhaul Winch, Inspect And Service | $0.00 | JOB | 1 | $0.00 |
| D-059 | Mechanical Chain Stoppers, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-060 | Anchor Windlass, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-061 | Anchor Chains and Ground Tackle, Inspect and Repair | $0.00 | JOB | 1 | $0.00 |
| D-062 | Anchor Chain and Ground Tackle, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-063 | Anchors, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-064 | Hawse Pipes, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-065 | Warping Capstan, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-066 | Hull Fittings (Mooring and Towing), Inspect and Test | $0.00 | JOB | 1 | $0.00 |
| D-067 | Single Point Davit, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-068 | Welin Lambie Dual Point Davit TWPIV 5.0B, Inspect, Test, and Overhaul | $0.00 | JOB | 1 | $0.00 |
| D-069 | Commissary Hoist, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-070 | Buoy Crane, Appleton EB600-60-40, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-071 | Grey Water Holding Tanks, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-072 | Sewage Holding Tanks, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-073 | Grey Water Piping, Clean and Flush | $0.00 | JOB | 1 | $0.00 |
| D-074 | Sewage Piping, Clean and Flush | $0.00 | JOB | 1 | $0.00 |
| O-075 | Accessible Voids, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| O-076 | Tanks, Ballast, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| O-077 | Chain Locker, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| D-078 | Accessible Void(s), Preserve, Partial, | $0.00 | JOB | 1 | $0.00 |
| 0-079 | Tanks, Potable Water, Preserve, Partial, | $0.00 | JOB | 1 | $0.00 |
| D-080 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | $0.00 | JOB | 1 | $0.00 |
| D-081 | Hull Plating Freeboard (Buoy Port Areas), Preserve | $0.00 | JOB | 1 | $0.00 |
| O-082 | Superstructure, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| D-083 | Cathodic Protection, Zinc Anodes, Renew, | $0.00 | JOB | 1 | $0.00 |
| D-084 | Impressed Current Cathodic Protection System, Inspect and Maintain | $0.00 | JOB | 1 | $0.00 |
| D-085 | Impressed Current, Cathodic Protection System, Reference Cells, Renew | $0.00 | JOB | 1 | $0.00 |
| D-086 | Drydock | $0.00 | JOB | 1 | $0.00 |
| D-087 | Temporary Services, Provide - Cutter | $0.00 | JOB | 1 | $0.00 |
| D-088 | Sea Trial Performance, Support, Provide | $0.00 | JOB | 1 | $0.00 |
| D-089 | Potable Water Pump Room Deck, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-090 | Bilges, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-091 | Deck Covering, Interior, Wet and Dry, Renew | $0.00 | JOB | 1 | $0.00 |
| D-092 | Space or Component, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-093 | Water Tight Hatches, Internal DC Deck and Below, Renew | $0.00 | JOB | 1 | $0.00 |
| D-094 | Watertight Doors and Scuttles, External, Renew | $0.00 | JOB | 1 | $0.00 |
| D-095 | Life Rail Renewal | $0.00 | JOB | 1 | $0.00 |
| D-096 | Missing Handgrabs, Install | $0.00 | JOB | 1 | $0.00 |
| D-097 | SW Ballast Tank TLI, Repair | $0.00 | JOB | 1 | $0.00 |
| D-098 | Fuel Oil (FO) Piping, Renew | $0.00 | JOB | 1 | $0.00 |
| D-099 | Circuit Breakers, Inspect, Maintain & Test | $0.00 | JOB | 1 | $0.00 |
| D-100 | Single Point Davit Ladder, Renew | $0.00 | JOB | 1 | $0.00 |
| D-101 | Exterior Deck Drain, Renew | $0.00 | JOB | 1 | $0.00 |
| D-102 | Shower Pan Renew | $0.00 | JOB | 1 | $0.00 |
| D-103 | Boat Deck, Port and Starboard, Removable Lifeline Latches, Modify | $0.00 | JOB | 1 | $0.00 |
| D-104 | Steering Gear Heat Exchanger, Modify | $0.00 | JOB | 1 | $0.00 |
| D-105 | Steering System PLC, Upgrade | $0.00 | JOB | 1 | $0.00 |
| D-106 | Galley Vent Ducting Modify | $0.00 | JOB | 1 | $0.00 |
| D-107 | Thruster Generator, Clean & Inspect | $0.00 | JOB | 1 | $0.00 |
| D-108 | Fluxgate Digital Compass System | $0.00 | JOB | 1 | $0.00 |
| D-109 | Directional Control Valve, Uprade | $0.00 | JOB | 1 | $0.00 |
| D-110 | Independent NACE Inspector (Level 3), Provide | $0.00 | NSP | 1 | $0.00 |
| D-111 | Tenting, Provide | $0.00 | NSP | 1 | $0.00 |
| O-00A | Composite Labor Rate | 0 | Hour | 500 | 0 |
| O-00Z | Laydays | $0.00 | Day | 5 | $0.00 |
| Total Price of Definite Items | $0.00 | ||||
| Total Price of Option Items | $0.00 | ||||
| Total Price of Definite and Optional Items | $0.00 |
&C(12/11/2024) Draft-3 - Page &P of &N
CostEstimateBreakdowns
| Composite Labor Rate | 55 | |||||||||||||||||||||||
| Assumed G&A Factor | 15% | |||||||||||||||||||||||
| Assumed Profit Factor | 10% | Direct Labor | Direct Material/Subs Cost | |||||||||||||||||||||
| ITEM | DESCRIPTION | UNIT PRICE | Sub-Contracted (put a "1" in the blank) | Total Labor Hours | Total Material & Subs (cost + G&A + profit) | Eng Tech | Machinest/Pipe Fitter | Electrician | Shipfitter | Welder | Firewatch | Insulator/Lagger | Painter | Gen Labor/Helper/Rigger | Supt/QA/NDT | Mat/Sub Cost 1 | Mat/Sub Cost 2 | Mat/Sub Cost 3 | Mat/Sub Cost 4 | Lab Rate | Area | WorkItemID | WIFileID | LoadData |
| D-001 | Fire Prevention Requirements «TYPE» | $ - 0 | 0 | 0 | 62 | Baltimore, MD | 11293 | 1 | 118 | |||||||||||||||
| D-002 | Hull Plating, U/W Body, Inspect | $ - 0 | 0 | 0 | 52 | Biloxi, MS | 5089 | 1 | 21 | |||||||||||||||
| D-003 | Hull Plating, U/W Body, Ultrasonic Testing | $ - 0 | 0 | 0 | 56 | Boston, MA | 23 | 1 | WLB 225B | |||||||||||||||
| D-004 | Hull Plating, Freeboard, Ultrasonic Testing | $ - 0 | 0 | 0 | 50 | Charleston, SC | 3999 | 1 | 0 | |||||||||||||||
| D-005 | U/W Body, Preserve, 100 percent | $ - 0 | 0 | 0 | 60 | Corpus Christi, TX | 1705 | 1 | 17 | |||||||||||||||
| D-006 | U/W Body, Preserve, Partial, Condition A | $ - 0 | 0 | 0 | 51 | Hampton Roads | 522 | 1 | 155 | |||||||||||||||
| D-007 | U/W Body, Preserve, Partial, Condition B | $ - 0 | 0 | 0 | 64 | Honolulu, HI | 523 | 1 | FY2025 | |||||||||||||||
| D-008 | U/W Body, Preserve, Partial, Condition C | $ - 0 | 0 | 0 | 55 | Houston, TX | 524 | 1 | DD | |||||||||||||||
| D-009 | Hull Plating Freeboard, Preserve, Partial | $ - 0 | 0 | 0 | 56 | Los Angeles, CA | 5236 | 1 | cutter | |||||||||||||||
| D-010 | Appendages, U/W, Leak Test | $ - 0 | 0 | 0 | 55 | Median Rate | 5158 | 1 | CYPRESS (WLB 225B) DD FQ4 KAH 25D3.doc | |||||||||||||||
| D-011 | Propulsion Shaft Fairwaters And Rope Guards, Inspect | $ - 0 | 0 | 0 | 49 | Miami | 5405 | 1 | ||||||||||||||||
| D-012 | Appendages, U/W, Internal, Preserve | $ - 0 | 0 | 0 | 50 | Narragansett Bay, RI | 42 | 1 | ||||||||||||||||
| D-013 | Chain Lockers, Clean and Inspect | $ - 0 | 0 | 0 | 55 | New London, CN | 46 | 1 | ||||||||||||||||
| D-014 | Voids, Non-Accessible, Leak Test | $ - 0 | 0 | 0 | 45 | New Orleans | 54 | 1 | ||||||||||||||||
| D-015 | Voids, Non-Accessible, Internal Surfaces, Preserve | $ - 0 | 0 | 0 | 62 | NYNY | 67 | 1 | ||||||||||||||||
| D-016 | Tanks, MP Fuel Service, Clean and Inspect | $ - 0 | 0 | 0 | 49 | Panama City, FL | 9875 | 1 | ||||||||||||||||
| D-017 | Tanks, Potable Water, Clean and Inspect | $ - 0 | 0 | 0 | 60 | Philadelphia, PA | 75 | 1 | ||||||||||||||||
| D-018 | Tanks, Ballast, Clean and Inspect | $ - 0 | 0 | 0 | 51 | Portland, ME | 3996 | 1 | ||||||||||||||||
| D-019 | Voids, Accessible, Clean and Inspect | $ - 0 | 0 | 0 | 57 | Portland, OR | 5420 | 1 | ||||||||||||||||
| D-020 | Tanks, Dirty Oil and Waste, Clean and Inspect | $ - 0 | 0 | 0 | 55 | San Diego, CA | 81 | 1 | ||||||||||||||||
| D-021 | Hydraulically Operated Cargo Hatch, Inspect and Service | $ - 0 | 0 | 0 | 67 | San Francisco, CA | 9591 | 1 | ||||||||||||||||
| D-022 | Main Reduction Gear, Overhaul | $ - 0 | 0 | 0 | 55 | Santa Barbara, CA | 10757 | 1 | ||||||||||||||||
| D-023 | Propulsion Shafting; Remove, Inspect, and Reinstall | $ - 0 | 0 | 0 | 55 | SE North Carolina | 5195 | 1 | ||||||||||||||||
| D-024 | Propulsion Shaft Seals, Mechanical Overhaul And Inflatable Renewal | $ - 0 | 0 | 0 | 65 | Seattle, WA | 9679 | 1 | ||||||||||||||||
| D-025 | Propulsion Shaft Seals, Bulkhead, Overhaul | $ - 0 | 0 | 0 | 48 | Tampa-St. Petersburg | 175 | 1 | ||||||||||||||||
| D-026 | Strain Gage Alignment, Check | $ - 0 | 0 | 0 | 60 | Wilmington, DE | 9708 | 1 | ||||||||||||||||
| D-027 | Propulsion Shafting, Optical or Laser Alignment Check | $ - 0 | 0 | 0 | 5103 | 1 | ||||||||||||||||||
| D-028 | Propulsion Tail Shaft Sleeve, Skim Cut | $ - 0 | 0 | 0 | 201 | 1 | ||||||||||||||||||
| D-029 | Propulsion Shaft Bearings, External, Check Clearances | $ - 0 | 0 | 0 | 10773 | 1 | ||||||||||||||||||
| D-030 | Propulsion Shaft Bearing, Stave Renewal | $ - 0 | 0 | 0 | 11139 | 1 | ||||||||||||||||||
| D-031 | Stern Tube Interior Surfaces, Preserve, 100 Percent | $ - 0 | 0 | 0 | 526 | 1 | ||||||||||||||||||
| D-032 | Controllable Pitch Propellers, Clean and Inspect | $ - 0 | 0 | 0 | 8500 | 1 | ||||||||||||||||||
| D-033 | Controllable Pitch Propeller, System Maintenance, Perform | $ - 0 | 0 | 0 | 860 | 1 | ||||||||||||||||||
| D-034 | Controllable Pitch Propeller Hub, General Maintenance with EAL, Perform | $ - 0 | 0 | 0 | 10678 | 1 | ||||||||||||||||||
| D-035 | CPP Cooler, Clean and Inspect | $ - 0 | 0 | 0 | 827 | 1 | ||||||||||||||||||
| D-036 | Controllable Pitch Propeller Hub, Remove and Reinstall | $ - 0 | 0 | 0 | 1076 | 1 | ||||||||||||||||||
| D-037 | Sea Water System Piping, Clean and Flush | $ - 0 | 0 | 0 | 2839 | 1 | ||||||||||||||||||
| D-038 | Heat Exchangers, Clean, Inspect And Hydro | $ - 0 | 0 | 0 | 245 | 1 | ||||||||||||||||||
| D-039 | Main Diesel Engine, MDE, Exhaust Piping, Commercial Clean | $ - 0 | 0 | 0 | 692 | 1 | ||||||||||||||||||
| D-040 | Ship Service Diesel Generator, SSDG, Exhaust Piping, Commercial Clean | $ - 0 | 0 | 0 | 693 | 1 | ||||||||||||||||||
| D-041 | Ship Service Diesel Generator, Clean and Inspect | $ - 0 | 0 | 0 | 274 | 1 | ||||||||||||||||||
| D-042 | Emergency Diesel Generator, Clean & Inspect | $ - 0 | 0 | 0 | 799 | 1 | ||||||||||||||||||
| D-043 | Fathometer Transducer, General Maintenance | $ - 0 | 0 | 0 | 10101 | 1 | ||||||||||||||||||
| D-044 | Fwd Scan Sonar Transducer, General Maintenance, Perform | $ - 0 | 0 | 0 | 1795 | 1 | ||||||||||||||||||
| D-045 | Vent Ducts, Engine And Motor Room, All, Commercial Cleaning | $ - 0 | 0 | 0 | 300 | 1 | ||||||||||||||||||
| D-046 | Vent Ducts, Galley and Pantry Room, All, Commercial Cleaning | $ - 0 | 0 | 0 | 301 | 1 | ||||||||||||||||||
| D-047 | Vent Ducts, Laundry Exhaust, Commercial Cleaning | $ - 0 | 0 | 0 | 302 | 1 | ||||||||||||||||||
| D-048 | Vent Ducts, All Other, Commercial Cleaning | $ - 0 | 0 | 0 | 303 | 1 | ||||||||||||||||||
| D-049 | Sea Valves and Waster Pieces, Overhaul Or Renew | $ - 0 | 0 | 0 | 2065 | 1 | ||||||||||||||||||
| D-050 | Sea Strainers, All Sizes, Renew | $ - 0 | 0 | 0 | 312 | 1 | ||||||||||||||||||
| D-051 | Sea Strainers, Duplex, All Sizes, Overhaul | $ - 0 | 0 | 0 | 314 | 1 | ||||||||||||||||||
| D-052 | Sea Strainers, Simplex, All Sizes, Clean and Inspect | $ - 0 | 0 | 0 | 315 | 1 | ||||||||||||||||||
| D-053 | Sea Bay, Clean and Inspect | $ - 0 | 0 | 0 | 2774 | 1 | ||||||||||||||||||
| D-054 | Sea Bay, Preserve 100% | $ - 0 | 0 | 0 | 2775 | 1 | ||||||||||||||||||
| D-055 | Potable Water Pneumatic Tanks, Clean and Inspect | $ - 0 | 0 | 0 | 3995 | 1 | ||||||||||||||||||
| D-056 | Compressed Air Receivers and System Valves, All, Clean, Inspect, Hydro and Lift | $ - 0 | 0 | 0 | 11361 | 1 | ||||||||||||||||||
| D-057 | Rudders, Preserve, 100 Percent | $ - 0 | 0 | 0 | 1869 | 1 | ||||||||||||||||||
| D-058 | Rudder Stock Bearings, Check Clearances | $ - 0 | 0 | 0 | 1243 | 1 | ||||||||||||||||||
| D-059 | Rudder, Inspect And Repair | $ - 0 | 0 | 0 | 1245 | 1 | ||||||||||||||||||
| D-060 | Rudder and Rudder Stock, Remove and Inspect | $ - 0 | 0 | 0 | 6680 | 1 | ||||||||||||||||||
| D-061 | Rudder Bearings, Renewal | $ - 0 | 0 | 0 | 1249 | 1 | ||||||||||||||||||
| D-062 | Thruster Units, Overhaul Fluid Change to EAL | $ - 0 | 0 | 0 | 10816 | 1 | ||||||||||||||||||
| D-063 | Hull Fittings (Weight Handling Rigging Hardware), Inspect and Test | $ - 0 | 0 | 0 | 5308 | 1 | ||||||||||||||||||
| D-064 | Hydraulic Chain Stoppers, Inspect And Service | $ - 0 | 0 | 0 | 5427 | 1 | ||||||||||||||||||
| D-065 | Crossdeck Winches, Inspect and Service | $ - 0 | 0 | 0 | 5419 | 1 | ||||||||||||||||||
| D-066 | Hydraulic Inhaul Winch, Inspect And Service | $ - 0 | 0 | 0 | 7702 | 1 | ||||||||||||||||||
| D-067 | Mechanical Chain Stoppers, Inspect and Service | $ - 0 | 0 | 0 | 7710 | 1 | ||||||||||||||||||
| D-068 | Anchor Windlass, Inspect and Service | $ - 0 | 0 | 0 | 7707 | 1 | ||||||||||||||||||
| D-069 | Anchor Chains and Ground Tackle, Inspect and Repair | $ - 0 | 0 | 0 | 718 | 1 | ||||||||||||||||||
| D-070 | Anchor Chain and Ground Tackle, Preserve | $ - 0 | 0 | 0 | 1787 | 1 | ||||||||||||||||||
| D-071 | Anchors, Preserve | $ - 0 | 0 | 0 | 1394 | 1 | ||||||||||||||||||
| D-072 | Hawse Pipes, Preserve | $ - 0 | 0 | 0 | 1890 | 1 | ||||||||||||||||||
| D-073 | Warping Capstan, Inspect and Service | $ - 0 | 0 | 0 | 7703 | 1 | ||||||||||||||||||
| D-074 | Hull Fittings (Mooring and Towing), Inspect and Test | $ - 0 | 0 | 0 | 6604 | 1 | ||||||||||||||||||
| D-075 | Single Point Davit, Inspect and Service | $ - 0 | 0 | 0 | 10754 | 1 | ||||||||||||||||||
| D-076 | Welin Lambie Dual Point Davit TWPIV 5.0B, Inspect, Test, and Overhaul | $ - 0 | 0 | 0 | 10755 | 1 | ||||||||||||||||||
| D-077 | Commissary Hoist, Inspect and Service | $ - 0 | 0 | 0 | 9618 | 1 | ||||||||||||||||||
| D-078 | Buoy Crane, Appleton EB600-60-40, Inspect and Service | $ - 0 | 0 | 0 | 10753 | 1 | ||||||||||||||||||
| D-079 | Grey Water Holding Tanks, Clean and Inspect | $ - 0 | 0 | 0 | 9871 | 1 | ||||||||||||||||||
| D-080 | Sewage Holding Tanks, Clean and Inspect | $ - 0 | 0 | 0 | 9873 | 1 | ||||||||||||||||||
| D-081 | Grey Water Piping, Clean and Flush | $ - 0 | 0 | 0 | 9874 | 1 | ||||||||||||||||||
| D-082 | Sewage Piping, Clean and Flush | $ - 0 | 0 | 0 | 455 | 1 | ||||||||||||||||||
| D-083 | Accessible Voids, Preserve, 100 Percent | $ - 0 | 0 | 0 | 3985 | 1 | ||||||||||||||||||
| D-084 | Tanks, Ballast, Preserve, 100 Percent | $ - 0 | 0 | 0 | 5108 | 1 | ||||||||||||||||||
| D-085 | Tanks, Ballast, Preserve, Partial | $ - 0 | 0 | 0 | 489 | 1 | ||||||||||||||||||
| D-086 | Chain Locker, Preserve, 100 Percent | $ - 0 | 0 | 0 | 2416 | 1 | ||||||||||||||||||
| D-087 | Accessible Void(s), Preserve, Partial, | $ - 0 | 0 | 0 | 505 | 1 | ||||||||||||||||||
| D-088 | Tanks, Potable Water, Preserve, Partial, | $ - 0 | 0 | 0 | 499 | 1 | ||||||||||||||||||
| D-089 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | $ - 0 | 0 | 0 | 2865 | 1 | ||||||||||||||||||
| D-090 | Hull Plating Freeboard (Buoy Port Areas), Preserve | $ - 0 | 0 | 0 | 5295 | 1 | ||||||||||||||||||
| D-091 | Superstructure, Preserve, Partial | $ - 0 | 0 | 0 | 5045 | 1 | ||||||||||||||||||
| D-092 | Cathodic Protection, Zinc Anodes, Renew, | $ - 0 | 0 | 0 | 542 | 1 | ||||||||||||||||||
| D-093 | Impressed Current Cathodic Protection System, Inspect and Maintain | $ - 0 | 0 | 0 | 2181 | 1 | ||||||||||||||||||
| D-094 | Impressed Current, Cathodic Protection System, Reference Cells, Renew | $ - 0 | 0 | 0 | 1648 | 1 | ||||||||||||||||||
| D-095 | Drydock | $ 149,250.00 | 1600 | 61250 | $1,600.00 | $49,000.00 | 555 | 1 | ||||||||||||||||
| D-096 | Temporary Services, Provide - Cutter | $ - 0 | 0 | 0 | 556 | 1 | ||||||||||||||||||
| D-097 | Sea Trial Performance, Support, Provide | $ - 0 | 0 | 0 | 563 | 1 | ||||||||||||||||||
| D-098 | Potable Water Pump Room Deck, Preserve | $ - 0 | 0 | 0 | 2561 | 1 | ||||||||||||||||||
| D-099 | Bilges, Preserve | $ - 0 | 0 | 0 | 5139 | 1 | ||||||||||||||||||
| D-100 | Deck Covering, Interior, Wet and Dry, Renew | $ - 0 | 0 | 0 | 1731 | 1 | ||||||||||||||||||
| D-101 | Space or Component, Preserve | $ - 0 | 0 | 0 | 684 | 24 | ||||||||||||||||||
| D-102 | Water Tight Hatches, Internal DC Deck and Below, Renew | $ - 0 | 0 | 0 | 662 | 1 | ||||||||||||||||||
| D-103 | Watertight Doors and Scuttles, External, Renew | $ - 0 | 0 | 0 | 665 | 1 | ||||||||||||||||||
| D-104 | Life Rail Renewal | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-105 | Missing Handgrabs, Install | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-106 | SW Ballast Tank TLI, Repair | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-107 | Fuel Oil (FO) Piping, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-108 | «Type» Circuit Breakers, Inspect, Maintain & Test | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-109 | Single Point Davit Ladder, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-110 | Exterior Deck Drain, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-111 | Shower Pan Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-112 | Boat Deck, Port and Starboard, Removable Lifeline Latches, Modify | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-113 | Steering Gear Heat Exchanger, Modify | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-114 | Steering System PLC, Upgrade | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-115 | Galley Vent Ducting Modify | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-116 | Thruster Generator, Clean & Inspect | $ - 0 | 0 | 0 | 11190 | 1 | ||||||||||||||||||
| D-117 | Independent NACE Inspector (Level 3), Provide | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-118 | Tenting, Provide | $ - 0 | 0 | 0 | 10000 | 0 |
&C(09/28/2009) Page &P of &N
CostEstimateTemplate
| Composite Labor Rate | 55 | ||||||||||||||||
| Assumed G&A Factor | 15% | ||||||||||||||||
| Assumed Profit Factor | 10% | Direct Labor | Direct Material/Subs Cost | ||||||||||||||
| Sub-Contracted (put a "1" in the blank) | Total Labor Hours | Total Material & Subs (cost + G&A + profit) | Eng Tech | Machinest/Pipe Fitter | Electrician | Shipfitter | Welder | Firewatch | Insulator/Lagger | Painter | Gen Labor/Helper/Rigger | Supt/QA/NDT | |||||
| DESCRIPTION | UNIT PRICE | Lab Rate | Area | ||||||||||||||
| $0 | 0 | $0 | 62 | Baltimore, MD | |||||||||||||
| $0 | 0 | $0 | 52 | Biloxi, MS | |||||||||||||
| $0 | 0 | $0 | 56 | Boston, MA | |||||||||||||
| $0 | 0 | $0 | 50 | Charleston, SC | |||||||||||||
| $0 | 0 | $0 | 60 | Corpus Christi, TX | |||||||||||||
| $0 | 0 | $0 | 64 | Honolulu, HI | |||||||||||||
| $0 | 0 | $0 | 55 | Houston, TX | |||||||||||||
| $0 | 0 | $0 | 56 | Los Angeles, CA | |||||||||||||
| $0 | 0 | $0 | 55 | Median Rate | |||||||||||||
| $0 | 0 | $0 | 55 | Median Rate | |||||||||||||
| $0 | 0 | $0 | 50 | Narragansett Bay, RI | |||||||||||||
| 55 | New London, CN | ||||||||||||||||
| 45 | New Orleans | ||||||||||||||||
| 62 | NYNY | ||||||||||||||||
| 49 | Panama City, FL | ||||||||||||||||
| 60 | Philadelphia, PA | ||||||||||||||||
| 51 | Portland, ME | ||||||||||||||||
| 57 | Portland, OR | ||||||||||||||||
| 55 | San Diego, CA | ||||||||||||||||
| 67 | San Francisco, CA | ||||||||||||||||
| 55 | Santa Barbara, CA | ||||||||||||||||
| 55 | SE North Carolina | ||||||||||||||||
| 65 | Seattle, WA | ||||||||||||||||
| 48 | Tampa-St. Petersburg | ||||||||||||||||
| 60 | Wilmington, DE |