William Tate - Request for Clarification 6.docx
DOCX document 24 KB Posted
- Attached to
- Dockside (DS): USCGC William Tate FY20 Repair
- Solicitation number
- 70Z085-20-Q-P4595400
About this file
This document contains a request for clarification regarding a solicitation for dockside repair services on the USCGC William Tate. The solicitation seeks a contractor to perform various dockside repairs on the vessel, including replacing fifteen stanchions located on the foc'sle, port bridge wing and fantail. Offerors are instructed to submit any clarification questions by 27 May 2020 to the Coast Guard contact via email. One question should be submitted per request for clarification form. This particular request seeks clarification on work item 032 regarding gas-freeing, asking that language be added to account for potential interferences that may be encountered when removing stanchions. The Coast Guard response provides further details on the stanchions to be replaced as listed in the solicitation and notes that all potential interferences at each location should be considered.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 3-William Tate DS.docx | DOCX document | |
| William Tate - Request for Clarification 1.docx | DOCX document | |
| William Tate - Request for Clarification 2.docx | DOCX document | |
| William Tate - Request for Clarification 3.docx | DOCX document | |
| William Tate - Request for Clarification 5.docx | DOCX document | |
| William Tate - Request for Clarification 4.docx | DOCX document | |
| Amendment 2-William Tate DS.doc | DOC document | |
| Amendment 2-William Tate DS.pdf | ||
| Amendment 1-William Tate DS.doc | DOC document | |
| Attachment 3 - William Tate - Past Performance Information Form.doc | DOC document | |
| Attachment 2 - William Tate - Specification Rev 1.doc | DOC document | |
| Attachment 1 - William Tate - Work Item Price List.xls | XLS spreadsheet | |
| William Tate Solicitation (final).doc | DOC document | |
| Attachment 4 - William Tate - Request for Clarification.docx | DOCX document | |
| Attachment 5 - William Tate - USCG Ombudsman Notice.doc | DOC document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offeror’s questions will be answered by an Amendment.
1. Offeror’s questions concerning this solicitation shall be submitted in writing, and must be submitted on the attached “Request for Clarification” form. One question should be submitted per form. Each form should indicate the name of the offeror’s firm.
2. Questions should be submitted via email to Andrew.G.Jacobs@uscg.mil.
REQUEST FOR CLARIFICATION
Submit requests not later than 27 May 2020 at 9:00 am Pacific Time
Offeror’s Name:
| Date: |
| 27 May 2020 |
Question No.
Six
FY20 Dockside repairs for CGC WILLIAM TATE
| RFQ Number: |
| 70Z085-20-Q-P4595400 |
SOLICITATION SECTION:
PARA NO.
| DEFINITE/OPTIONAL ITEM NO. |
| Work Item 032 |
| PARA NO. |
| 3.1.4 |
TITLE:
Gas Free
QUESTION: Table 1 does not delineate the stanchions to be repaired? At the site visit, only three stanchions were identified. The other twelve are to be designated. The interferences and attachments are not known therefore and since the stanchions are welded directly to the deck, interferences below may vary greatly. Adding “Removal of wire runs or ventilation ducting as required to access the overhead in the space below the stanchions will be per CR” would reduce the base cost of the Work Item since the Contractor does not have to assume the worst case scenario.
RESPONSE: All stanchions to be renewed are listed in table 1. “Stanchion renewal section” 15 total. All nine stanchions on the Foc’sle are to be replaced. / All three stanchions on the port bridge wing are to be replaced and all three stanchions on frame 90-95 are to be replaced. All interferences located at “Frame/Location” in the table should be considered.
| Component |
| Quantity |
| diameter (inches) |
| material |
| Frame LOCATION |
| Stanchion |
| 3ea |
| 2” |
| TYP SCH 40 |
| Port bridge wing |
| Stanchion |
| 9ea |
| 2” |
| TYP SCH 40 |
| 01 /Forecastle |
| Stanchion |
| 3ea |
| 2” |
| TYP SCH 40 |
| Fantail FR 90-95 |
Attachment 4