William Tate - Request for Clarification 5.docx

DOCX document 22 KB Posted

Attached to
Dockside (DS): USCGC William Tate FY20 Repair
Solicitation number
70Z085-20-Q-P4595400
Issued by

About this file

This document contains a request for clarification and the related federal contract opportunity solicitation. The request for clarification concerns dockside repairs for the USCGC WILLIAM TATE, including a question about whether the contractor must gas free the emergency diesel fuel tank since the piping is directly connected to the tank. The response indicates that gas freeing the tank is required in accordance with the standard specification.

The federal contract opportunity solicitation seeks dockside repair services for the USCGC WILLIAM TATE, a 175-foot buoy coastal tender. The contractor must furnish all necessary facilities, labor, materials, services, equipment and supplies to perform various dockside repairs in accordance with the solicitation and attached specification. The solicitation was issued by the Department of Homeland Security US Coast Guard.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offeror’s questions will be answered by an Amendment.

1. Offeror’s questions concerning this solicitation shall be submitted in writing, and must be submitted on the attached “Request for Clarification” form. One question should be submitted per form. Each form should indicate the name of the offeror’s firm.

2. Questions should be submitted via email to Andrew.G.Jacobs@uscg.mil.

REQUEST FOR CLARIFICATION

Submit requests not later than 27 May 2020 at 9:00 am Pacific Time

Offeror’s Name:

Date:
27 May 2020

Question No.

Five

FY20 Dockside repairs for CGC WILLIAM TATE

RFQ Number:
70Z085-20-Q-P4595400

SOLICITATION SECTION:

PARA NO.

DEFINITE/OPTIONAL ITEM NO.
Work Item 030
PARA NO.
3.2

TITLE:

Gas Free

QUESTION: Will the Contractor be required to gas free the Emer Diesel Fuel Tank since the piping is directly connected to the tank?

RESPONSE: Yes, … IAW Standard specification 0740