907 Dock Street St. Louis, MO 63147 Ph: (314) 739-1155 Fax: (314) 739-1166

E-Mail: info@gencorpservices.com

Asbestos and Lead Assessment

USCG Surface Force Logistics Center

Timothy Shuhart 300 East Main Street, Suite 600

Norfolk, VA 23510

CGC SLEDGE

2401 HAWKINS POINT ROAD

BALTIMORE, MD 21226

PROJECT 17A058

March 2017

TABLE OF CONTENTS

1.0 Summary

1.1 Compartment and Task List

2.0 Findings and Assessments (Asbestos Containing Material)

2.1 Tender One Hold

2.2 Barge BOSN Hole

2.3 Barge Engine Room

2.4 Barge Forward Engineering

2.5 Barge Line Locker

2.6 Barge Forward ATON Hold

2.7 Barge Rigging Hold

2.8 Barge EM Shop

2.9 Tender Ventilation

2.10 Tender Mess Deck & Galley

2.11 Tender CO Berthing Area

2.12 Tender EPO/XPO Berthing

2.13 Tender Crew Berthing

2.14 Tender Engine Room

2.15 Tender Shaft Alley

2.16 Tender Main Deck Passageways & Ladders

2.17 Tender 01 Deck Passageways & Ladders

2.18 Lazarette

2.19 MSD Space

2.20 Barge Forward Rake

3.0 Pictures: Asbestos Containing Material

4.0 Analytical Data (ACM Bulk Sampling)

5.0 Analytical Data (Asbestos Aggressive Air)

6.0 Findings and Assessments (Lead Based Paint)

6.1 Tender One Hold

6.2 Barge BOSN Hole

6.3 Barge Engine Room

6.4 Barge Forward Engineering

6.5 Barge Line Locker

6.6 Forward ATON Hold

6.7 Barge Rigging Hold

6.8 Barge EM Shop

6.9 Tender Ventilation

6.10 Tender Mess Deck & Galley

6.11 Tender CO Berthing Area

6.12 Tender EPO/XPO Berthing Area

6.13 Tender Crew Berthing Area

6.14 Tender Engine Room

6.15 Tender Shaft Alley

6.16 Tender Main Deck Passageways & Ladders

6.17 Tender 01 Deck Passageways & Ladders

6.18 Lazarette

6.19 MSD Space

6.20 Barge Forward Rake

7.0 Pictures: Lead Based Paint

8.0 Analytical Data (Lead Based Paint Bulk Sampling)

9.0 Analytical Data (Lead Dust Wipe Sampling Results)

10.0 Licenses

1.0 SUMMARY

From March 23 - 26 2017, GenCorp Services sampled and assessed the compartments listed below on the CGC Sledge. Asbestos Containing Material Bulk Sampling, Asbestos Air Sampling, Lead Paint Bulk Sampling and Lead Dust Wipe Sampling were conducted in these compartments.

SanAir Technologies Laboratory analyzed the samples. The results, summary of the findings, and our recommendations are in the following sections. Not all areas were visible at the time of sampling and the quantities listed may not be an accurate representation.

1.1 Compartment and Task List

Location Type of Sample Number of Samples

Tender One Hold ACM Aggressive Air Sample 06

Tender One Hold Lead Paint Wipes 10

Barge BOSN Hole Lead Paint Wipes 10

Barge BOSN Hole ACM Aggressive Air Sample 06

Barge Engine Room ACM Aggressive Air Sample 12

Barge Engine Room Lead Paint Wipes 10

Barge Engineering Storage ACM Aggressive Air Sample 08

Barge Engineering Storage Lead Paint Wipes 10

Barge Line Locker ACM Aggressive Air Sample 06

Barge Line Locker Lead Paint Wipes 10

Barge Forward ATON Hold ACM Aggressive Air Sample 06

Barge Forward ATON Hold Lead Paint Wipes 10

Barge RIGGING Hold ACM Aggressive Air Sample 06

Barge RIGGING Hold Lead Paint Wipes 10

Barge EM Shop ACM Aggressive Air Sample 04

Barge EM Shop Lead Paint Wipes 10

Tender Ventilation ACM Aggressive Air Sample 08

Tender Ventilation Lead Paint Wipes 10

Tender Mess Deck and Galley ACM Aggressive Air Sample 06

Tender Mess Deck and Galley Lead Paint Wipes 10

Tender CO Berthing Area ACM Aggressive Air Sample 04

Tender CO Berthing Area Lead Paint Wipes 10

Tender EPO/XPO Berthing Area ACM Aggressive Air Sample 04

Tender EPO/XPO Berthing Area Lead Paint Wipes 10

Tender Crew Berthing Area ACM Aggressive Air Sample 06

Tender Crew Berthing Area Lead Paint Wipes 10

Tender Engine Room ACM Aggressive Air Sample 08

Tender Engine Room Lead Paint Wipes 10

Tender Shaft Alley ACM Aggressive Air Sample 06

Tender Shaft Alley Lead Paint Wipes 10

Tender Main Deck Passageway & Ladders

ACM Aggressive Air Sample 08

Tender Main Deck Passageway & Ladders

Lead Paint Wipes 20

Tender 01 Deck Passageway & Ladders

ACM Aggressive Air Sample 08

Tender 01 Deck Passageway & Ladders

Lead Paint Wipes 20

Lazarette ACM Aggressive Air Sample 05

Lazarette Lead Paint Wipes 10

Lazarette ACM Bulk Sample 03

Lazarette Lead Paint Bulk Sample 03

MSD Space ACM Aggressive Air Sample 05

MSD Space Lead Paint Wipes 10

MSD Space ACM Bulk Sample 01

MSD Space Lead Paint Bulk Sample 01

Barge Forward Rake Lead Paint Bulk Sample 04

Barge Forward Rake ACM Bulk Sample 04

2.0 FINDINGS AND ASSESSMENTS (ASBESTOS CONTAINING MATERIAL)

2.1 Tender One Hold

Aggressive Air Sampling Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

OH – AG01 One Hold Port Center

PCM <5.5 <0.001

OH – AG02 One Hold Forward Starboard

PCM 8 0.002

OH – AG03 One Hold Forward Port

PCM <5.5 <0.001

OH – AG04 One Hold AFT Port

PCM 6 0.002

OH – AG05 One Hold AFT Center

PCM <5.5 <0.001

OH – AG06 One Hold Forward Center

PCM <5.5 <0.01

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

Recommendations Throughout Area:

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air sampling results are below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.

• The overhead and bulkheads appear to be deteriorated but many areas have been encapsulated. Area should be abated or stabilized if found to contain asbestos.

• The deck appears to be intact.

2.2 Barge BOSN Hole

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

BH – AG01 BOSN Hole Center Center

PCM Overloaded

BH – AG02 BOSN Hole Port Forward

PCM Overloaded

BH – AG03 BOSN Hole Port Center

PCM Overloaded

BH – AG04 BOSN Hole Port AFT

PCM Overloaded

BH – AG05 BOSN Hole Starboard Center

PCM Overloaded

BH – AG06 BOSN Hole Starboard AFT

PCM Overloaded

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead and bulkheads appear to be deteriorated. Area should be abated or stabilized if found to contain asbestos.

• The forward bulkhead consists of lockers, I beams and L beams.

2.3 Barge Engine Room

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

BER – AG01 Barge Engine Room Starboard AFT

PCM Overloaded

BER – AG02 Barge Engine Room Port AFT

PCM Overloaded

BER – AG03 Barge Engine Room Port Center

PCM Overloaded

BER – AG04 Barge Engine Room Center AFT

PCM Overloaded

BER – AG05 Barge Engine Room Port Forward

PCM Overloaded

BER – AG06 Barge Engine Room Center Center

PCM Overloaded

BER – AG07 Barge Engine Room Starboard Forward

PCM Overloaded

BER – AG08 Barge Engine Room Center Forward

PCM Overloaded

BER – AG09 Barge Engine Room Starboard Center

PCM Overloaded

BER – AG10 Barge Engine Room AFT Center

PCM Overloaded

BER – AG11 Barge Engine Room Center Forward

PCM Overloaded

BER – AG12 Barge Engine Room Port Center

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead and bulkheads appear to be deteriorated but many areas have been encapsulated. Area should be abated or stabilized if found to contain asbestos.

• The aft bulkhead consists of lockers, I beams and L beams.

2.4 Barge Forward Engineering

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

FE – AG01 Forward Engineering Port Forward

PCM Overloaded

FE – AG02 Forward Engineering Port Center

PCM Overloaded

FE – AG03 Forward Engineering Port AFT

PCM Overloaded

FE – AG04 Forward Engineering Starboard Forward

PCM Overloaded

FE – AG05 Forward Engineering Starboard Center

PCM Overloaded

FE – AG06 Forward Engineering Starboard AFT

PCM Overloaded

FE – AG07 Forward Engineering Center Forward

PCM Overloaded

FE – AG08 Forward Engineering Center AFT

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead and deck appear to be deteriorated. Area should be abated or stabilized if found to contain asbestos.

• The bulkheads appear to be intact.

2.5 Barge Line Locker

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

LL – AG01 Line Locker Port Forward

PCM Overload

LL – AG02 Line Locker Port Center

PCM Overload

LL – AG03 Line Locker Port AFT

PCM Overload

LL – AG04 Line Locker Starboard Forward

PCM Overload

LL – AG05 Line Locker Starboard Center

PCM Overload

LL – AG06 Line Locker

PCM Overload

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead, AFT bulkhead, Port bulkhead and STBD bulkhead appear to be deteriorated.

Area should be abated or stabilized if found to contain asbestos.

• The deck and forward bulkhead appear to be intact.

2.6 Barge Forward ATON Hold

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

FA – AG01 Forward ATON Hold Port Forward

PCM Overloaded

FA – AG02 Forward ATON Hold Port Center

PCM Overloaded

FA – AG03 Forward ATON Hold Port AFT

PCM Overloaded

FA – AG04 Forward ATON Hold Starboard Forward

PCM Overloaded

FA – AG05 Forward ATON Hold Starboard Center

PCM Overloaded

FA – AG06 Forward ATON Hold

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead and bulkheads appear to be deteriorated but many areas have been encapsulated. Area should be abated or stabilized if found to contain asbestos.

2.7 Barge Rigging Hold

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

RH – AG01 Rigging Hold Port Forward

PCM Overloaded

RH – AG02 Rigging Hold Port AFT

PCM Overloaded

RH – AG03 Rigging Hold Port Center

PCM Overloaded

RH – AG04 Rigging Hold Starboard Center

PCM Overloaded

RH – AG05 Rigging Hold Starboard Center

PCM Overloaded

RH – AG06 Rigging Hold

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead, deck and bulkheads appear to be intact.

2.8 Barge EM Shop

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

ES – AG01 EM Shop Starboard AFT

PCM Overloaded

ES – AG02 EM Shop Port AFT

PCM Overloaded

ES – AG03 EM Shop Port Forward

PCM Overloaded

ES – AG04 EM Shop Starboard Forward

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead and deck appear to be deteriorated. Area should be abated or stabilized if found to contain asbestos.

• The bulkheads appear to be intact.

2.9 Tender Ventilation

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

VT – AG01 Ventilation Forward Port

PCM 7 0.002

VT – AG02 Ventilation Forward Port

PCM <5.5 <0.001

VT – AG03 Ventilation Forward Center

PCM <5.5 <0.001

VT – AG04 Ventilation Forward Starboard

PCM 6 0.002

VT – AG05 Ventilation Forward Starboard

PCM 8 0.002

VT – AG06 Ventilation AFT Port

PCM <5.5 <0.001

VT – AG07 Ventilation AFT Center

PCM <5.5 <0.001

VT – AG08 Ventilation AFT Starboard

PCM <5.5 <0.001

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air sampling results are below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.

• The ducts appear to be intact.

2.10 Tender Mess Deck & Galley

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

MD – AG01 Mess Deck Forward Port

PCM 18 0.005

MD – AG02 Mess Deck Forward Center

PCM 16 0.004

MD – AG03 Mess Deck Forward Starboard

PCM 21 0.006

MD – AG04 Mess Deck AFT Starboard

PCM 19 0.005

MD – AG05 Mess Deck AFT Center

PCM 14 0.004

MD – AG06 Mess Deck AFT Port

PCM 25 0.007

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air sampling results are below the OSHA approved exposure limit of 0.01 fibers/cc and

2.11 Tender CO Berthing Area

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

CO – AG01 CO Berthing Forward Port

PCM Overloaded

CO – AG02 CO Berthing Port Center

PCM Overloaded

CO – AG03 CO Berthing AFT Port

PCM Overloaded

CO – AG04 CO Berthing Starboard

PCM 13 0.004

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• One of air sampling results was below the OSHA approved exposure limit of 0.01 fibers/cc.

Three of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

2.12 Tender EPO/XPO Berthing

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

EPO – AG01 EPO Berthing Starboard Center

PCM 16 0.004

EPO – AG02 EPO Berthing AFT Center

PCM 18 0.005

EPO – AG03 EPO Berthing Center Center

PCM Overloaded

EPO – AG04 EPO Berthing Starboard Center

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• Two of air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc.

Two of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

2.13 Tender Crew Berthing

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

CB – AG01 Crew Berthing Starboard Forward

PCM 24 0.007

CB – AG02 Crew Berthing Starboard Center

PCM 7 0.002

CB – AG03 Crew Berthing Starboard AFT

PCM 14 0.004

CB – AG04 Crew Berthing AFT Center

PCM 20 0.005

CB – AG05 Crew Berthing Forward Center

PCM 19 0.005

CB – AG06 Crew Berthing Port Forward

PCM 25 0.007

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc and

2.14 Tender Engine Room

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

TER – AG01 Tender Engine Room Port Center

PCM 20 0.005

TER – AG02 Tender Engine Room Port AFT

PCM 16 0.004

TER – AG03 Tender Engine Room Forward Port

PCM 19 0.005

TER – AG04 Tender Engine Room Forward Starboard

PCM 23 0.006

TER – AG05 Tender Engine Room Center Forward

PCM 20 0.005

TER – AG06 Tender Engine Room Center Center

PCM 17 0.005

TER – AG07 Tender Engine Room AFT Port

PCM <5.5 <0.001

TER – AG08 Tender Engine Room Center AFT

PCM 22 0.006

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.

• The overhead appears to be deteriorated. Area should be abated or stabilized if found to contain asbestos.

• The deck and bulkheads appear to be intact.

2.15 Tender Shaft Alley

ACM Bulk Sampling Sample # Sample Location Material

Description % of Asbestos Actions Required Notes

SA – A01 Shaft Alley Potable Water

Tank Forward Starboard

Spray on Material None Detected None

SA – A02 Shaft Alley Overhead

AFT Starboard

Insulation None Detected None

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

SA – AG01 Shaft Alley AFT Starboard

PCM Overloaded

SA – AG02 Shaft Alley AFT Center

PCM Overloaded

SA – AG03 Shaft Alley AFT Port

PCM Overloaded

SA – AG04 Shaft Alley Forward Starboard

PCM Overloaded

SA – AG05 Shaft Alley Forward Center

PCM Overloaded

SA – AG06 Shaft Alley Forward Port

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

Overhead:

• No further action is required on the materials that tested negative for asbestos.

• Area appeared to be intact.

Deck:

• No sampling was performed.

• Area appeared to be intact.

Aft Bulkhead:

• No sampling was performed.

• Area appeared to be intact.

Starboard Bulkhead:

• No sampling was performed.

• Area appeared to be intact.

Forward Bulkhead:

• No sampling was performed.

• Area appeared to be intact.

Port Bulkhead:

• No sampling was performed.

• Area appeared to be intact Other:

• Potable Water Tank o No further action is required on the materials that tested negative for asbestos.

o Area appeared to be intact.

2.16 Tender Main Deck Passageways & Ladders

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

MP – AG01 Main Passage AFT Port

PCM Overload

MP – AG02 Main Passage Center Port

PCM Overload

MP – AG03 Main Passage Center Starboard

PCM Overload

MP – AG04 Main Passage Forward Starboard

PCM 26 0.007

MP – AG05 Main Passage Center Port

PCM Overload

MP – AG06 Main Passage Center Starboard

PCM 21 0.006

MP – AG07 Main Passage Forward Starboard

PCM 19 0.005

MP – AG08 Main Passage Center Starboard

PCM 24 0.007

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• Four of the air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc. Four of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead, deck and bulkheads appears to be intact.

2.17 Tender 01 Deck Passageways & Ladders

Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes

01P – AG01 01 Passageway Forward Head

PCM 16 0.004

01P – AG02 01 Passageway Port Pilothouse

PCM <5.5 <0.001

01P – AG03 01 Passageway Port Passageway

PCM 12 0.003

01P – AG04 01 Passageway Lower Stairwell

PCM 21 0.006

01P – AG05 01 Passageway AFT Head

PCM 24 0.007

01P – AG06 01 Passageway Starboard Passageway

PCM 20 0.005

01P – AG07 01 Passageway Pilothouse Stairwell

PCM 15 0.004

01P – AG08 01 Passageway Starboard Pilothouse

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• Seven of the air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc. One of the air samples was overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

• The overhead, deck, bulkheads and ladders appear to be intact.

• Air sampling was conducted in the Pilothouse and 01 head but areas were not assessed.

2.18 Lazarette

Sample # Sample Location Material

Description % of Asbestos Actions Required Notes

LAZ – A1 Lazarette Overhead

Forward Starboard

Spray on Material 2% Chrysotile Abatement

LAZ – A2 Lazarette Overhead

Forward Starboard

Spray on Material Coating

2% Chrysotile Abatement

LAZ – A3 Lazarette AFT Bulkhead

Center

Spray on Material Coating

None Detected None

LAZ – AG01 Lazarette Forward Port

PCM <5.5 <0.001

LAZ – AG02 Lazarette Forward Starboard

PCM Overloaded

LAZ – AG03 Lazarette AFT Port

PCM Overloaded

LAZ – AG04 Lazarette AFT Starboard

PCM Overloaded

LAZ – AG05 Lazarette AFT Center

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• One of the air sampling results was below the OSHA approved exposure limit of 0.01 fibers/cc. Four of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.

Overhead:

• The spray on material tested positive for the presence of asbestos.

• The overhead should be properly abated or stabilized.

• Area was deteriorating.

Deck:

• No sampling was performed on the Deck.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Forward Bulkhead:

• Positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.

• Area appeared to be intact.

AFT Bulkhead:

• The spray on material tested for the negative of asbestos.

• However, positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.

• Area appeared to be intact.

Port Bulkhead:

• No sampling was performed.

• Positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.

• Area appeared to be intact.

Starboard Bulkhead:

• No sampling was performed.

• Positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.

• Area appeared to be intact.

2.19 MSD Space

Sample # Sample Location Material

Description % of Asbestos Actions Required Notes

MSD – A01 MSD Space Overhead Port

Coating None Detected None

MSD – AG01 MSD Space Forward Port

PCM 10 0.003

MSD – AG02 MSD Space Forward Starboard

PCM 7 0.002

MSD – AG03 MSD Space Forward Center

PCM <5.5 <0.001

MSD – AG04 MSD Space AFT Port

PCM 6 0.002

MSD – AG05 MSD Space AFT Starboard

PCM 7 0.002

Note: All samples were below OSHA approved exposure limits and therefore no further action is required.

• If materials are found and suspected to contain asbestos, they should be tested before disturbed.

• The air sampling results was below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.

Overhead:

• No further action is required on the materials that tested negative for asbestos.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Deck:

• No sampling was performed.

• Area appeared to be intact.

Forward Bulkhead:

• No sampling was performed.

• Area appeared to be intact.

Aft Bulkhead:

• No sampling was performed.

• Area appeared to be intact.

Port Bulkhead:

• No sampling was performed.

• Area appeared to be intact.

Starboard Bulkhead:

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Other:

• Sewage Tank o No sampling was performed.

o Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

2.20 Barge Forward Rake

Sample # Sample Location Material

Description % of Asbestos Actions Required Notes

FR – A01 Forward Rake Overhead

Starboard Center

Coating None Detected None

FR – A02 Forward Rake Port Bulkhead

AFT

Coating None Detected None

FR – A03 Forward Rake AFT Bulkhead

Starboard

Debris None Detected None

FR – A04 Forward Rake Center

Spray on Material Coating

None Detected None

• If other materials are found and suspected to contain asbestos, they should be tested before disturbed.

Overhead:

• No further action is required on the materials that tested negative for asbestos.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Deck:

• No sampling was performed.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Aft Bulkhead:

• No further action is required on the materials that tested negative for asbestos.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Starboard Bulkhead:

• No sampling was performed.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Forward Bulkhead:

• No sampling was performed.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Port Bulkhead:

• No further action is required on the materials that tested negative for asbestos.

• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

Other:

• Mid Line Frame Support o No further action is required on the materials that tested negative for asbestos.

o Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.

3.0 PICTURES: ASBESTOS CONTAINING MATERIAL

SA—A01 SHAFT ALLEY

Potable Water Tank

Forward Starboard

SA—A02 SHAFT ALLEY

Overhead

AFT Starboard

LAZ—A01 LAZARETTE

Overhead

Forward Starboard

LAZ—A02 LAZARETTE

Forward Starboard

LAZ—A03 LAZARETTE

AFT Bulkhead

Center

MSD—A01 MSD SPACE

Port

FR –A01 FORWARD RAKE

Overhead

Starboard Center

FR—A02 FORWARD RAKE

Port Bulkhead

AFT

FR—A03 FORWARD RAKE

AFT Bulkhead

Starboard

FR –A04 FORWARD RAKE

Mid Line Frame Support

Center

4.0 ANALYTICAL DATA (ACM BULK SAMPLING)

SanAir Technologies LaboratorySanAir Technologies Laboratory

Analysis Report prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010688

804.897.1177 www.sanair.com804.897.1177 www.sanair.com

SanAir Technologies Laboratory, Inc.

1551 Oakbridge Drive, Suite B, Powhatan, VA 23139

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010688 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 2 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): SA-A01, SA-A02.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

2 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/24/2017

3/27/2017 9:35:00 AM

3/27/2017 11:09:50 AM

Robertson, Erin

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers SA-A01 / 17010688-001 White 2% Cellulose 98% Other None Detected Shaft Alley - Other Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers SA-A02 / 17010688-002 Yellow 97% Glass 3% Other None Detected Shaft Alley - Overhead Fibrous

Homogeneous

17010688 SanAir ID Number

FINAL REPORT

Certification

Analyst: Approved Signatory:

Analysis Date: 3/27/2017 Date: 3/27/2017 Page 3 of 6

Disclaimer

The final report cannot be reproduced, except in full, without written authorization from SanAir.

Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

NY ELAP lab ID 11983 prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010683

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010683 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 3 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): LAS-A01, LAS-A02, LAS-A03.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

3 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/23/2017

3/27/2017 9:35:00 AM

3/27/2017 11:38:19 AM

Toth, Elizabeth

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LAS-A01 / 17010683-001 Various 98% Other 2% Chrysotile Lazarette - Overhead Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LAS-A02 / 17010683-002 Various 98% Other 2% Chrysotile Lazarette - Overhead Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LAS-A03 / 17010683-003 White 100% Other None Detected Lazarette - Aft Bulkhead Non-Fibrous

Heterogeneous

17010683 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 3/27/2017 Date: 3/27/2017 Page 3 of 5 accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010680

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010680 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 1 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): MSD-A01.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

1 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/24/2017

3/27/2017 9:35:00 AM

3/27/2017 11:05:15 AM

Fleming, Christopher

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers MSD-A01 / 17010680-001 Various 100% Other None Detected MSD Space - Overhead Non-Fibrous

Homogeneous

17010680 SanAir ID Number

FINAL REPORT

Certification accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010686

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010686 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 4 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): FR-A01, FR-A02, FR-A03, FR-A04.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

4 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/23/2017

3/27/2017 9:35:00 AM

3/27/2017 11:08:11 AM

Rouillard, Elliott

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A01 / 17010686-001 Various 100% Other None Detected Forward Rake - Overhead Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A02 / 17010686-002 Various 100% Other None Detected Forward Rake - Port Bulkhead Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A03 / 17010686-003 Red 100% Other None Detected Forward Rake - Aft Bulkhead Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A04 / 17010686-004 Black 100% Other None Detected Forward Rake - Other, Spray On Non-Fibrous Material Homogeneous

FR-A04 / 17010686-004 White 100% Other None Detected Forward Rake - Other, Coating Non-Fibrous

Homogeneous

17010686 SanAir ID Number

FINAL REPORT

Certification accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or

5.0 ANALYTICAL DATA (ASBESTOS AGGRESSIVE AIR)

prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010674

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010674 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): OH-AG01, OH-AG02, OH-AG03, OH-AG04, OH-AG05, OH-AG06.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

6 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/25/2017

3/27/2017 9:35:00 AM

3/27/2017 12:31:04 PM

Weakley, Alison

Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

OH-AG01 One Hold - Port Ctr 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-001

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

OH-AG02 One Hold - Fwd Stbd 1800 8 100 0.001 0.240.00210.191 17010674-002

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

OH-AG03 One Hold - Fwd Port 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-003

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

OH-AG04 One Hold - Aft Port 1800 6 100 0.001 0.240.0027.643 17010674-004

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

OH-AG05 One Hold - Aft Ctr 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-005

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

OH-AG06 One Hold - Fwd Ctr 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-006

17010674 SanAir ID Number

FINAL REPORT

Certification

Final reports cannot be reproduced, except in full, without written authorization from SanAir.

Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.

governmental agencies; and may not be certified by every local, state and federal regulatory agencies.

Revision date 8/31/2013 prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010696

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010696 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): BH-AG01, BH-AG02, BH-AG03, BH-AG04, BH-AG05, BH-AG06.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/23/2017

3/27/2017 9:35:00 AM

3/27/2017 1:52:24 PM

Weakley, Alison

Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BH-AG01 Bosn Hole - Center 1800 Overloaded 17010696-001 Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BH-AG02 Bosn Hole - Port Fwd 1800 Overloaded 17010696-002

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BH-AG03 Bosn Hole - Port 1800 Overloaded 17010696-003 Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BH-AG04 Bosn Hole - Port Aft 1800 Overloaded 17010696-004

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BH-AG05 Bosn Hole - 1800 Overloaded 17010696-005 Starboard Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BH-AG06 Bosn Hole - 1800 Overloaded 17010696-006 Starboard Aft

17010696 SanAir ID Number

FINAL REPORT

Certification

Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.

prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010690

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010690 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 12 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): BER-AG01, BER-AG02, BER-AG03, BER-AG04, BER-AG05, BER-AG06, BER-AG07, BER-AG08, BER-AG09, BER-AG10, BER-AG11, BER-AG12.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

12 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/23/2017

3/27/2017 9:35:00 AM

3/27/2017 1:34:52 PM

Weakley, Alison

Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG01 Bange Engine Room - 1800 Overloaded 17010690-001 Starboard Aft

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG02 Bange Engine Room - 1800 Overloaded 17010690-002 Port Aft

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG03 Bange Engine Room - 1800 Overloaded 17010690-003 Port Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG04 Bange Engine Room - 1800 Overloaded 17010690-004 Center Aft

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG05 Bange Engine Room - 1800 Overloaded 17010690-005 Port Forward

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG06 Bange Engine Room - 1800 Overloaded 17010690-006 Center Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG07 Bange Engine Room - 1800 Overloaded 17010690-007 Starboard Forward

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG08 Bange Engine Room - 1800 Overloaded 17010690-008 Center Forward

17010690 SanAir ID Number

FINAL REPORT

Certification

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/23/2017

3/27/2017 9:35:00 AM

3/27/2017 1:34:52 PM

Weakley, Alison

Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG09 Bange Engine Room - 1800 Overloaded 17010690-009 Stbd Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG10 Bange Engine Room - 1800 Overloaded 17010690-010 Aft Center

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG11 Bange Engine Room - 1800 Overloaded 17010690-011 Center Forward

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

BER-AG12 Bange Engine Room - 1800 Overloaded 17010690-012 Port Center

17010690 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 3/27/2017 Date: 3/27/2017 Page 4 of 6

Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.

prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010695

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010695 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 8 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): FE-AG01, FE-AG02, FE-AG03, FE-AG04, FE-AG05, FE-AG06, FE-AG07, FE-AG08.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

8 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

GenCorp Services 907 Dock St St. Louis, MO 63147

Project Number:

P.O. Number:

Project Name: CGC Sledge

Collected Date:

Received Date:

Report Date:

Analyst:

3/24/2017

3/27/2017 9:35:00 AM

3/27/2017 1:50:53 PM

Weakley, Alison

Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG01 Forward Engineer - 1800 Overloaded 17010695-001 Port Fwd

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG02 Forward Engineer - 1800 Overloaded 17010695-002 Port Ctr

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG03 Forward Engineer - 1800 Overloaded 17010695-003 Port Aft

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG04 Forward Engineer - 1800 Overloaded 17010695-004 Stbd Fwd

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG05 Forward Engineer - 1800 Overloaded 17010695-005 Stbd Ctr

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG06 Forward Engineer - 1800 Overloaded 17010695-006 Stbd Aft

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG07 Forward Engineer - 1800 Overloaded 17010695-007 Ctr Fwd

Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2

FE-AG08 Forward Engineer - 1800 Overloaded 17010695-008 Ctr Aft

17010695 SanAir ID Number

FINAL REPORT

Certification

Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.

prepared for

GenCorp Services

Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010705

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

GenCorp Services 907 Dock St St. Louis, MO 63147

March 27, 2017

SanAir ID # 17010705 Project Name: CGC Sledge Project Number:

Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): LL-AG01, LL-AG02, LL-AG03, LL-AG04, LL-AG05, LL-AG06.