907 Dock Street St. Louis, MO 63147 Ph: (314) 739-1155 Fax: (314) 739-1166
E-Mail: info@gencorpservices.com
Asbestos and Lead Assessment
USCG Surface Force Logistics Center
Timothy Shuhart 300 East Main Street, Suite 600
Norfolk, VA 23510
CGC SLEDGE
2401 HAWKINS POINT ROAD
BALTIMORE, MD 21226
PROJECT 17A058
March 2017
TABLE OF CONTENTS
1.0 Summary
1.1 Compartment and Task List
2.0 Findings and Assessments (Asbestos Containing Material)
2.1 Tender One Hold
2.2 Barge BOSN Hole
2.3 Barge Engine Room
2.4 Barge Forward Engineering
2.5 Barge Line Locker
2.6 Barge Forward ATON Hold
2.7 Barge Rigging Hold
2.8 Barge EM Shop
2.9 Tender Ventilation
2.10 Tender Mess Deck & Galley
2.11 Tender CO Berthing Area
2.12 Tender EPO/XPO Berthing
2.13 Tender Crew Berthing
2.14 Tender Engine Room
2.15 Tender Shaft Alley
2.16 Tender Main Deck Passageways & Ladders
2.17 Tender 01 Deck Passageways & Ladders
2.18 Lazarette
2.19 MSD Space
2.20 Barge Forward Rake
3.0 Pictures: Asbestos Containing Material
4.0 Analytical Data (ACM Bulk Sampling)
5.0 Analytical Data (Asbestos Aggressive Air)
6.0 Findings and Assessments (Lead Based Paint)
6.1 Tender One Hold
6.2 Barge BOSN Hole
6.3 Barge Engine Room
6.4 Barge Forward Engineering
6.5 Barge Line Locker
6.6 Forward ATON Hold
6.7 Barge Rigging Hold
6.8 Barge EM Shop
6.9 Tender Ventilation
6.10 Tender Mess Deck & Galley
6.11 Tender CO Berthing Area
6.12 Tender EPO/XPO Berthing Area
6.13 Tender Crew Berthing Area
6.14 Tender Engine Room
6.15 Tender Shaft Alley
6.16 Tender Main Deck Passageways & Ladders
6.17 Tender 01 Deck Passageways & Ladders
6.18 Lazarette
6.19 MSD Space
6.20 Barge Forward Rake
7.0 Pictures: Lead Based Paint
8.0 Analytical Data (Lead Based Paint Bulk Sampling)
9.0 Analytical Data (Lead Dust Wipe Sampling Results)
10.0 Licenses
1.0 SUMMARY
From March 23 - 26 2017, GenCorp Services sampled and assessed the compartments listed below on the CGC Sledge. Asbestos Containing Material Bulk Sampling, Asbestos Air Sampling, Lead Paint Bulk Sampling and Lead Dust Wipe Sampling were conducted in these compartments.
SanAir Technologies Laboratory analyzed the samples. The results, summary of the findings, and our recommendations are in the following sections. Not all areas were visible at the time of sampling and the quantities listed may not be an accurate representation.
1.1 Compartment and Task List
Location Type of Sample Number of Samples
Tender One Hold ACM Aggressive Air Sample 06
Tender One Hold Lead Paint Wipes 10
Barge BOSN Hole Lead Paint Wipes 10
Barge BOSN Hole ACM Aggressive Air Sample 06
Barge Engine Room ACM Aggressive Air Sample 12
Barge Engine Room Lead Paint Wipes 10
Barge Engineering Storage ACM Aggressive Air Sample 08
Barge Engineering Storage Lead Paint Wipes 10
Barge Line Locker ACM Aggressive Air Sample 06
Barge Line Locker Lead Paint Wipes 10
Barge Forward ATON Hold ACM Aggressive Air Sample 06
Barge Forward ATON Hold Lead Paint Wipes 10
Barge RIGGING Hold ACM Aggressive Air Sample 06
Barge RIGGING Hold Lead Paint Wipes 10
Barge EM Shop ACM Aggressive Air Sample 04
Barge EM Shop Lead Paint Wipes 10
Tender Ventilation ACM Aggressive Air Sample 08
Tender Ventilation Lead Paint Wipes 10
Tender Mess Deck and Galley ACM Aggressive Air Sample 06
Tender Mess Deck and Galley Lead Paint Wipes 10
Tender CO Berthing Area ACM Aggressive Air Sample 04
Tender CO Berthing Area Lead Paint Wipes 10
Tender EPO/XPO Berthing Area ACM Aggressive Air Sample 04
Tender EPO/XPO Berthing Area Lead Paint Wipes 10
Tender Crew Berthing Area ACM Aggressive Air Sample 06
Tender Crew Berthing Area Lead Paint Wipes 10
Tender Engine Room ACM Aggressive Air Sample 08
Tender Engine Room Lead Paint Wipes 10
Tender Shaft Alley ACM Aggressive Air Sample 06
Tender Shaft Alley Lead Paint Wipes 10
Tender Main Deck Passageway & Ladders
ACM Aggressive Air Sample 08
Tender Main Deck Passageway & Ladders
Lead Paint Wipes 20
Tender 01 Deck Passageway & Ladders
ACM Aggressive Air Sample 08
Tender 01 Deck Passageway & Ladders
Lead Paint Wipes 20
Lazarette ACM Aggressive Air Sample 05
Lazarette Lead Paint Wipes 10
Lazarette ACM Bulk Sample 03
Lazarette Lead Paint Bulk Sample 03
MSD Space ACM Aggressive Air Sample 05
MSD Space Lead Paint Wipes 10
MSD Space ACM Bulk Sample 01
MSD Space Lead Paint Bulk Sample 01
Barge Forward Rake Lead Paint Bulk Sample 04
Barge Forward Rake ACM Bulk Sample 04
2.0 FINDINGS AND ASSESSMENTS (ASBESTOS CONTAINING MATERIAL)
2.1 Tender One Hold
Aggressive Air Sampling Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
OH – AG01 One Hold Port Center
PCM <5.5 <0.001
OH – AG02 One Hold Forward Starboard
PCM 8 0.002
OH – AG03 One Hold Forward Port
PCM <5.5 <0.001
OH – AG04 One Hold AFT Port
PCM 6 0.002
OH – AG05 One Hold AFT Center
PCM <5.5 <0.001
OH – AG06 One Hold Forward Center
PCM <5.5 <0.01
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
Recommendations Throughout Area:
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air sampling results are below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.
• The overhead and bulkheads appear to be deteriorated but many areas have been encapsulated. Area should be abated or stabilized if found to contain asbestos.
• The deck appears to be intact.
2.2 Barge BOSN Hole
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
BH – AG01 BOSN Hole Center Center
PCM Overloaded
BH – AG02 BOSN Hole Port Forward
PCM Overloaded
BH – AG03 BOSN Hole Port Center
PCM Overloaded
BH – AG04 BOSN Hole Port AFT
PCM Overloaded
BH – AG05 BOSN Hole Starboard Center
PCM Overloaded
BH – AG06 BOSN Hole Starboard AFT
PCM Overloaded
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead and bulkheads appear to be deteriorated. Area should be abated or stabilized if found to contain asbestos.
• The forward bulkhead consists of lockers, I beams and L beams.
2.3 Barge Engine Room
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
BER – AG01 Barge Engine Room Starboard AFT
PCM Overloaded
BER – AG02 Barge Engine Room Port AFT
PCM Overloaded
BER – AG03 Barge Engine Room Port Center
PCM Overloaded
BER – AG04 Barge Engine Room Center AFT
PCM Overloaded
BER – AG05 Barge Engine Room Port Forward
PCM Overloaded
BER – AG06 Barge Engine Room Center Center
PCM Overloaded
BER – AG07 Barge Engine Room Starboard Forward
PCM Overloaded
BER – AG08 Barge Engine Room Center Forward
PCM Overloaded
BER – AG09 Barge Engine Room Starboard Center
PCM Overloaded
BER – AG10 Barge Engine Room AFT Center
PCM Overloaded
BER – AG11 Barge Engine Room Center Forward
PCM Overloaded
BER – AG12 Barge Engine Room Port Center
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead and bulkheads appear to be deteriorated but many areas have been encapsulated. Area should be abated or stabilized if found to contain asbestos.
• The aft bulkhead consists of lockers, I beams and L beams.
2.4 Barge Forward Engineering
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
FE – AG01 Forward Engineering Port Forward
PCM Overloaded
FE – AG02 Forward Engineering Port Center
PCM Overloaded
FE – AG03 Forward Engineering Port AFT
PCM Overloaded
FE – AG04 Forward Engineering Starboard Forward
PCM Overloaded
FE – AG05 Forward Engineering Starboard Center
PCM Overloaded
FE – AG06 Forward Engineering Starboard AFT
PCM Overloaded
FE – AG07 Forward Engineering Center Forward
PCM Overloaded
FE – AG08 Forward Engineering Center AFT
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead and deck appear to be deteriorated. Area should be abated or stabilized if found to contain asbestos.
• The bulkheads appear to be intact.
2.5 Barge Line Locker
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
LL – AG01 Line Locker Port Forward
PCM Overload
LL – AG02 Line Locker Port Center
PCM Overload
LL – AG03 Line Locker Port AFT
PCM Overload
LL – AG04 Line Locker Starboard Forward
PCM Overload
LL – AG05 Line Locker Starboard Center
PCM Overload
LL – AG06 Line Locker
PCM Overload
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead, AFT bulkhead, Port bulkhead and STBD bulkhead appear to be deteriorated.
Area should be abated or stabilized if found to contain asbestos.
• The deck and forward bulkhead appear to be intact.
2.6 Barge Forward ATON Hold
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
FA – AG01 Forward ATON Hold Port Forward
PCM Overloaded
FA – AG02 Forward ATON Hold Port Center
PCM Overloaded
FA – AG03 Forward ATON Hold Port AFT
PCM Overloaded
FA – AG04 Forward ATON Hold Starboard Forward
PCM Overloaded
FA – AG05 Forward ATON Hold Starboard Center
PCM Overloaded
FA – AG06 Forward ATON Hold
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead and bulkheads appear to be deteriorated but many areas have been encapsulated. Area should be abated or stabilized if found to contain asbestos.
2.7 Barge Rigging Hold
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
RH – AG01 Rigging Hold Port Forward
PCM Overloaded
RH – AG02 Rigging Hold Port AFT
PCM Overloaded
RH – AG03 Rigging Hold Port Center
PCM Overloaded
RH – AG04 Rigging Hold Starboard Center
PCM Overloaded
RH – AG05 Rigging Hold Starboard Center
PCM Overloaded
RH – AG06 Rigging Hold
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead, deck and bulkheads appear to be intact.
2.8 Barge EM Shop
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
ES – AG01 EM Shop Starboard AFT
PCM Overloaded
ES – AG02 EM Shop Port AFT
PCM Overloaded
ES – AG03 EM Shop Port Forward
PCM Overloaded
ES – AG04 EM Shop Starboard Forward
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead and deck appear to be deteriorated. Area should be abated or stabilized if found to contain asbestos.
• The bulkheads appear to be intact.
2.9 Tender Ventilation
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
VT – AG01 Ventilation Forward Port
PCM 7 0.002
VT – AG02 Ventilation Forward Port
PCM <5.5 <0.001
VT – AG03 Ventilation Forward Center
PCM <5.5 <0.001
VT – AG04 Ventilation Forward Starboard
PCM 6 0.002
VT – AG05 Ventilation Forward Starboard
PCM 8 0.002
VT – AG06 Ventilation AFT Port
PCM <5.5 <0.001
VT – AG07 Ventilation AFT Center
PCM <5.5 <0.001
VT – AG08 Ventilation AFT Starboard
PCM <5.5 <0.001
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air sampling results are below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.
• The ducts appear to be intact.
2.10 Tender Mess Deck & Galley
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
MD – AG01 Mess Deck Forward Port
PCM 18 0.005
MD – AG02 Mess Deck Forward Center
PCM 16 0.004
MD – AG03 Mess Deck Forward Starboard
PCM 21 0.006
MD – AG04 Mess Deck AFT Starboard
PCM 19 0.005
MD – AG05 Mess Deck AFT Center
PCM 14 0.004
MD – AG06 Mess Deck AFT Port
PCM 25 0.007
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air sampling results are below the OSHA approved exposure limit of 0.01 fibers/cc and
2.11 Tender CO Berthing Area
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
CO – AG01 CO Berthing Forward Port
PCM Overloaded
CO – AG02 CO Berthing Port Center
PCM Overloaded
CO – AG03 CO Berthing AFT Port
PCM Overloaded
CO – AG04 CO Berthing Starboard
PCM 13 0.004
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• One of air sampling results was below the OSHA approved exposure limit of 0.01 fibers/cc.
Three of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
2.12 Tender EPO/XPO Berthing
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
EPO – AG01 EPO Berthing Starboard Center
PCM 16 0.004
EPO – AG02 EPO Berthing AFT Center
PCM 18 0.005
EPO – AG03 EPO Berthing Center Center
PCM Overloaded
EPO – AG04 EPO Berthing Starboard Center
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• Two of air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc.
Two of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
2.13 Tender Crew Berthing
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
CB – AG01 Crew Berthing Starboard Forward
PCM 24 0.007
CB – AG02 Crew Berthing Starboard Center
PCM 7 0.002
CB – AG03 Crew Berthing Starboard AFT
PCM 14 0.004
CB – AG04 Crew Berthing AFT Center
PCM 20 0.005
CB – AG05 Crew Berthing Forward Center
PCM 19 0.005
CB – AG06 Crew Berthing Port Forward
PCM 25 0.007
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc and
2.14 Tender Engine Room
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
TER – AG01 Tender Engine Room Port Center
PCM 20 0.005
TER – AG02 Tender Engine Room Port AFT
PCM 16 0.004
TER – AG03 Tender Engine Room Forward Port
PCM 19 0.005
TER – AG04 Tender Engine Room Forward Starboard
PCM 23 0.006
TER – AG05 Tender Engine Room Center Forward
PCM 20 0.005
TER – AG06 Tender Engine Room Center Center
PCM 17 0.005
TER – AG07 Tender Engine Room AFT Port
PCM <5.5 <0.001
TER – AG08 Tender Engine Room Center AFT
PCM 22 0.006
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.
• The overhead appears to be deteriorated. Area should be abated or stabilized if found to contain asbestos.
• The deck and bulkheads appear to be intact.
2.15 Tender Shaft Alley
ACM Bulk Sampling Sample # Sample Location Material
Description % of Asbestos Actions Required Notes
SA – A01 Shaft Alley Potable Water
Tank Forward Starboard
Spray on Material None Detected None
SA – A02 Shaft Alley Overhead
AFT Starboard
Insulation None Detected None
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
SA – AG01 Shaft Alley AFT Starboard
PCM Overloaded
SA – AG02 Shaft Alley AFT Center
PCM Overloaded
SA – AG03 Shaft Alley AFT Port
PCM Overloaded
SA – AG04 Shaft Alley Forward Starboard
PCM Overloaded
SA – AG05 Shaft Alley Forward Center
PCM Overloaded
SA – AG06 Shaft Alley Forward Port
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
Overhead:
• No further action is required on the materials that tested negative for asbestos.
• Area appeared to be intact.
Deck:
• No sampling was performed.
• Area appeared to be intact.
Aft Bulkhead:
• No sampling was performed.
• Area appeared to be intact.
Starboard Bulkhead:
• No sampling was performed.
• Area appeared to be intact.
Forward Bulkhead:
• No sampling was performed.
• Area appeared to be intact.
Port Bulkhead:
• No sampling was performed.
• Area appeared to be intact Other:
• Potable Water Tank o No further action is required on the materials that tested negative for asbestos.
o Area appeared to be intact.
2.16 Tender Main Deck Passageways & Ladders
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
MP – AG01 Main Passage AFT Port
PCM Overload
MP – AG02 Main Passage Center Port
PCM Overload
MP – AG03 Main Passage Center Starboard
PCM Overload
MP – AG04 Main Passage Forward Starboard
PCM 26 0.007
MP – AG05 Main Passage Center Port
PCM Overload
MP – AG06 Main Passage Center Starboard
PCM 21 0.006
MP – AG07 Main Passage Forward Starboard
PCM 19 0.005
MP – AG08 Main Passage Center Starboard
PCM 24 0.007
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• Four of the air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc. Four of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead, deck and bulkheads appears to be intact.
2.17 Tender 01 Deck Passageways & Ladders
Sample # Sample Location Sampling Method Fiber Count Fibers/cc Notes
01P – AG01 01 Passageway Forward Head
PCM 16 0.004
01P – AG02 01 Passageway Port Pilothouse
PCM <5.5 <0.001
01P – AG03 01 Passageway Port Passageway
PCM 12 0.003
01P – AG04 01 Passageway Lower Stairwell
PCM 21 0.006
01P – AG05 01 Passageway AFT Head
PCM 24 0.007
01P – AG06 01 Passageway Starboard Passageway
PCM 20 0.005
01P – AG07 01 Passageway Pilothouse Stairwell
PCM 15 0.004
01P – AG08 01 Passageway Starboard Pilothouse
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• Seven of the air sampling results were below the OSHA approved exposure limit of 0.01 fibers/cc. One of the air samples was overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
• The overhead, deck, bulkheads and ladders appear to be intact.
• Air sampling was conducted in the Pilothouse and 01 head but areas were not assessed.
2.18 Lazarette
Sample # Sample Location Material
Description % of Asbestos Actions Required Notes
LAZ – A1 Lazarette Overhead
Forward Starboard
Spray on Material 2% Chrysotile Abatement
LAZ – A2 Lazarette Overhead
Forward Starboard
Spray on Material Coating
2% Chrysotile Abatement
LAZ – A3 Lazarette AFT Bulkhead
Center
Spray on Material Coating
None Detected None
LAZ – AG01 Lazarette Forward Port
PCM <5.5 <0.001
LAZ – AG02 Lazarette Forward Starboard
PCM Overloaded
LAZ – AG03 Lazarette AFT Port
PCM Overloaded
LAZ – AG04 Lazarette AFT Starboard
PCM Overloaded
LAZ – AG05 Lazarette AFT Center
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• One of the air sampling results was below the OSHA approved exposure limit of 0.01 fibers/cc. Four of the air samples were overloaded and therefore it is recommended to conduct ACM Dust Wipe Sampling.
Overhead:
• The spray on material tested positive for the presence of asbestos.
• The overhead should be properly abated or stabilized.
• Area was deteriorating.
Deck:
• No sampling was performed on the Deck.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Forward Bulkhead:
• Positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.
• Area appeared to be intact.
AFT Bulkhead:
• The spray on material tested for the negative of asbestos.
• However, positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.
• Area appeared to be intact.
Port Bulkhead:
• No sampling was performed.
• Positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.
• Area appeared to be intact.
Starboard Bulkhead:
• No sampling was performed.
• Positive ACM results on the overhead and therefore the area should be considered positive for ACM and should be properly abated or stabilized.
• Area appeared to be intact.
2.19 MSD Space
Sample # Sample Location Material
Description % of Asbestos Actions Required Notes
MSD – A01 MSD Space Overhead Port
Coating None Detected None
MSD – AG01 MSD Space Forward Port
PCM 10 0.003
MSD – AG02 MSD Space Forward Starboard
PCM 7 0.002
MSD – AG03 MSD Space Forward Center
PCM <5.5 <0.001
MSD – AG04 MSD Space AFT Port
PCM 6 0.002
MSD – AG05 MSD Space AFT Starboard
PCM 7 0.002
Note: All samples were below OSHA approved exposure limits and therefore no further action is required.
• If materials are found and suspected to contain asbestos, they should be tested before disturbed.
• The air sampling results was below the OSHA approved exposure limit of 0.01 fibers/cc and therefore no further action is required.
Overhead:
• No further action is required on the materials that tested negative for asbestos.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Deck:
• No sampling was performed.
• Area appeared to be intact.
Forward Bulkhead:
• No sampling was performed.
• Area appeared to be intact.
Aft Bulkhead:
• No sampling was performed.
• Area appeared to be intact.
Port Bulkhead:
• No sampling was performed.
• Area appeared to be intact.
Starboard Bulkhead:
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Other:
• Sewage Tank o No sampling was performed.
o Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
2.20 Barge Forward Rake
Sample # Sample Location Material
Description % of Asbestos Actions Required Notes
FR – A01 Forward Rake Overhead
Starboard Center
Coating None Detected None
FR – A02 Forward Rake Port Bulkhead
AFT
Coating None Detected None
FR – A03 Forward Rake AFT Bulkhead
Starboard
Debris None Detected None
FR – A04 Forward Rake Center
Spray on Material Coating
None Detected None
• If other materials are found and suspected to contain asbestos, they should be tested before disturbed.
Overhead:
• No further action is required on the materials that tested negative for asbestos.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Deck:
• No sampling was performed.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Aft Bulkhead:
• No further action is required on the materials that tested negative for asbestos.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Starboard Bulkhead:
• No sampling was performed.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Forward Bulkhead:
• No sampling was performed.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Port Bulkhead:
• No further action is required on the materials that tested negative for asbestos.
• Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
Other:
• Mid Line Frame Support o No further action is required on the materials that tested negative for asbestos.
o Area was deteriorating. Area should be abated or stabilized if found to contain asbestos.
3.0 PICTURES: ASBESTOS CONTAINING MATERIAL
SA—A01 SHAFT ALLEY
Potable Water Tank
Forward Starboard
SA—A02 SHAFT ALLEY
Overhead
AFT Starboard
LAZ—A01 LAZARETTE
Overhead
Forward Starboard
LAZ—A02 LAZARETTE
Forward Starboard
LAZ—A03 LAZARETTE
AFT Bulkhead
Center
MSD—A01 MSD SPACE
Port
FR –A01 FORWARD RAKE
Overhead
Starboard Center
FR—A02 FORWARD RAKE
Port Bulkhead
AFT
FR—A03 FORWARD RAKE
AFT Bulkhead
Starboard
FR –A04 FORWARD RAKE
Mid Line Frame Support
Center
4.0 ANALYTICAL DATA (ACM BULK SAMPLING)
SanAir Technologies LaboratorySanAir Technologies Laboratory
Analysis Report prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010688
804.897.1177 www.sanair.com804.897.1177 www.sanair.com
SanAir Technologies Laboratory, Inc.
1551 Oakbridge Drive, Suite B, Powhatan, VA 23139
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010688 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 2 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): SA-A01, SA-A02.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
2 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/24/2017
3/27/2017 9:35:00 AM
3/27/2017 11:09:50 AM
Robertson, Erin
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers SA-A01 / 17010688-001 White 2% Cellulose 98% Other None Detected Shaft Alley - Other Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers SA-A02 / 17010688-002 Yellow 97% Glass 3% Other None Detected Shaft Alley - Overhead Fibrous
Homogeneous
17010688 SanAir ID Number
FINAL REPORT
Certification
Analyst: Approved Signatory:
Analysis Date: 3/27/2017 Date: 3/27/2017 Page 3 of 6
Disclaimer
The final report cannot be reproduced, except in full, without written authorization from SanAir.
Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.
NY ELAP lab ID 11983 prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010683
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010683 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 3 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): LAS-A01, LAS-A02, LAS-A03.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
3 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/23/2017
3/27/2017 9:35:00 AM
3/27/2017 11:38:19 AM
Toth, Elizabeth
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LAS-A01 / 17010683-001 Various 98% Other 2% Chrysotile Lazarette - Overhead Non-Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LAS-A02 / 17010683-002 Various 98% Other 2% Chrysotile Lazarette - Overhead Non-Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LAS-A03 / 17010683-003 White 100% Other None Detected Lazarette - Aft Bulkhead Non-Fibrous
Heterogeneous
17010683 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 3/27/2017 Date: 3/27/2017 Page 3 of 5 accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010680
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010680 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 1 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): MSD-A01.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
1 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/24/2017
3/27/2017 9:35:00 AM
3/27/2017 11:05:15 AM
Fleming, Christopher
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers MSD-A01 / 17010680-001 Various 100% Other None Detected MSD Space - Overhead Non-Fibrous
Homogeneous
17010680 SanAir ID Number
FINAL REPORT
Certification accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010686
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010686 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 4 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): FR-A01, FR-A02, FR-A03, FR-A04.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
4 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/23/2017
3/27/2017 9:35:00 AM
3/27/2017 11:08:11 AM
Rouillard, Elliott
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A01 / 17010686-001 Various 100% Other None Detected Forward Rake - Overhead Non-Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A02 / 17010686-002 Various 100% Other None Detected Forward Rake - Port Bulkhead Non-Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A03 / 17010686-003 Red 100% Other None Detected Forward Rake - Aft Bulkhead Non-Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers FR-A04 / 17010686-004 Black 100% Other None Detected Forward Rake - Other, Spray On Non-Fibrous Material Homogeneous
FR-A04 / 17010686-004 White 100% Other None Detected Forward Rake - Other, Coating Non-Fibrous
Homogeneous
17010686 SanAir ID Number
FINAL REPORT
Certification accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or
5.0 ANALYTICAL DATA (ASBESTOS AGGRESSIVE AIR)
prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010674
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010674 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): OH-AG01, OH-AG02, OH-AG03, OH-AG04, OH-AG05, OH-AG06.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
6 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/25/2017
3/27/2017 9:35:00 AM
3/27/2017 12:31:04 PM
Weakley, Alison
Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
OH-AG01 One Hold - Port Ctr 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-001
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
OH-AG02 One Hold - Fwd Stbd 1800 8 100 0.001 0.240.00210.191 17010674-002
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
OH-AG03 One Hold - Fwd Port 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-003
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
OH-AG04 One Hold - Aft Port 1800 6 100 0.001 0.240.0027.643 17010674-004
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
OH-AG05 One Hold - Aft Ctr 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-005
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
OH-AG06 One Hold - Fwd Ctr 1800 <5.5 100 0.001 0.24<0.0017.006 17010674-006
17010674 SanAir ID Number
FINAL REPORT
Certification
Final reports cannot be reproduced, except in full, without written authorization from SanAir.
Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.
governmental agencies; and may not be certified by every local, state and federal regulatory agencies.
Revision date 8/31/2013 prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010696
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010696 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): BH-AG01, BH-AG02, BH-AG03, BH-AG04, BH-AG05, BH-AG06.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/23/2017
3/27/2017 9:35:00 AM
3/27/2017 1:52:24 PM
Weakley, Alison
Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BH-AG01 Bosn Hole - Center 1800 Overloaded 17010696-001 Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BH-AG02 Bosn Hole - Port Fwd 1800 Overloaded 17010696-002
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BH-AG03 Bosn Hole - Port 1800 Overloaded 17010696-003 Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BH-AG04 Bosn Hole - Port Aft 1800 Overloaded 17010696-004
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BH-AG05 Bosn Hole - 1800 Overloaded 17010696-005 Starboard Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BH-AG06 Bosn Hole - 1800 Overloaded 17010696-006 Starboard Aft
17010696 SanAir ID Number
FINAL REPORT
Certification
Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.
prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010690
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010690 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 12 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): BER-AG01, BER-AG02, BER-AG03, BER-AG04, BER-AG05, BER-AG06, BER-AG07, BER-AG08, BER-AG09, BER-AG10, BER-AG11, BER-AG12.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
12 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/23/2017
3/27/2017 9:35:00 AM
3/27/2017 1:34:52 PM
Weakley, Alison
Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG01 Bange Engine Room - 1800 Overloaded 17010690-001 Starboard Aft
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG02 Bange Engine Room - 1800 Overloaded 17010690-002 Port Aft
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG03 Bange Engine Room - 1800 Overloaded 17010690-003 Port Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG04 Bange Engine Room - 1800 Overloaded 17010690-004 Center Aft
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG05 Bange Engine Room - 1800 Overloaded 17010690-005 Port Forward
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG06 Bange Engine Room - 1800 Overloaded 17010690-006 Center Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG07 Bange Engine Room - 1800 Overloaded 17010690-007 Starboard Forward
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG08 Bange Engine Room - 1800 Overloaded 17010690-008 Center Forward
17010690 SanAir ID Number
FINAL REPORT
Certification
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/23/2017
3/27/2017 9:35:00 AM
3/27/2017 1:34:52 PM
Weakley, Alison
Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG09 Bange Engine Room - 1800 Overloaded 17010690-009 Stbd Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG10 Bange Engine Room - 1800 Overloaded 17010690-010 Aft Center
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG11 Bange Engine Room - 1800 Overloaded 17010690-011 Center Forward
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
BER-AG12 Bange Engine Room - 1800 Overloaded 17010690-012 Port Center
17010690 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 3/27/2017 Date: 3/27/2017 Page 4 of 6
Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.
prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010695
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010695 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 8 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): FE-AG01, FE-AG02, FE-AG03, FE-AG04, FE-AG05, FE-AG06, FE-AG07, FE-AG08.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
8 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
GenCorp Services 907 Dock St St. Louis, MO 63147
Project Number:
P.O. Number:
Project Name: CGC Sledge
Collected Date:
Received Date:
Report Date:
Analyst:
3/24/2017
3/27/2017 9:35:00 AM
3/27/2017 1:50:53 PM
Weakley, Alison
Asbestos Air PCM NIOSH 7400 Method Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG01 Forward Engineer - 1800 Overloaded 17010695-001 Port Fwd
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG02 Forward Engineer - 1800 Overloaded 17010695-002 Port Ctr
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG03 Forward Engineer - 1800 Overloaded 17010695-003 Port Aft
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG04 Forward Engineer - 1800 Overloaded 17010695-004 Stbd Fwd
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG05 Forward Engineer - 1800 Overloaded 17010695-005 Stbd Ctr
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG06 Forward Engineer - 1800 Overloaded 17010695-006 Stbd Aft
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG07 Forward Engineer - 1800 Overloaded 17010695-007 Ctr Fwd
Sample Location Volume Fibers Fields LOD Fibers/ Fibers/ RSD ccmm2
FE-AG08 Forward Engineer - 1800 Overloaded 17010695-008 Ctr Aft
17010695 SanAir ID Number
FINAL REPORT
Certification
Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. Samples were received in good condition unless otherwise noted on the report. Limit of Detection is 7 fibers/mm². This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S.
prepared for
GenCorp Services
Report Date: 3/27/2017 Project Name: CGC Sledge SanAir ID#: 17010705
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
GenCorp Services 907 Dock St St. Louis, MO 63147
March 27, 2017
SanAir ID # 17010705 Project Name: CGC Sledge Project Number:
Dear Thomas Dougherty, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Monday, March 27, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): LL-AG01, LL-AG02, LL-AG03, LL-AG04, LL-AG05, LL-AG06.
These results…