This document is a reference file containing facility information and photographs for Building #5 (Gymnasium) located at USCG Base Elizabeth City in North Carolina, with Real Property Unique Identifier (RPUID) #24032.
The gymnasium is a two-story structure with a 26-foot interior ceiling height on the second floor, featuring a main gym space measuring 109 feet by 49 feet. The building contains administrative offices, mechanical rooms, bathrooms, a kitchen/food service area, and associated support spaces. The facility has experienced significant wind damage to its curved roof section, with temporary repairs currently in place consisting of blue tarpaulin coverings. Interior damage includes sheetrock replacement with plywood in affected areas. The building is accessed via multiple gates on the USCG Base and is situated near the Pasquotank River. Photographs document the building's exterior views from four directions (north, east, west, and south), interior gymnasium views, roof conditions before and after wind damage, and temporary repair efforts. The facility measurements indicated in the plan view are noted as approximate.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Building 5 Drawing.pdf | ||
| 70Z08126QELIZ0008 QA.pdf | ||
| SF-1442.pdf | ||
| SF25A Payment Bond.pdf | ||
| SF25 Performance Bond.pdf | ||
| Clauses and Provisions.pdf | ||
| B5 Roof Repair SOW.pdf | ||
| Wage Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page 1 of 14 Reference (a)
Pasquotank River
Back Gate
Front Gate
Page 2 of 14 Reference (a)
26 Ft. Interior Ceiling Height
Building# 5 - Gymnasium
Page 3 of 14 Reference (a)
Real Property Unique Identifier (RPUID)# - 24032
Front – North Side
Page 4 of 14 Reference (a)
East Side
Page 5 of 14 Reference (a)
West Side
Page 6 of 14 Reference (a)
Rear - South Side
Page 7 of 14 Reference (a)
24032
Gym View #1
Page 8 of 14 Reference (a)
Gym View #2
Page 9 of 14 Reference (a)
Interior View – Sheetrock Replaced with Plywood
Page 10 of 14 Reference (a)
Flat Roof View
Page 11 of 14 Reference (a)
Curved Roof View BEFORE Wind Damage
Page 12 of 14 Reference (a)
Curved Roof Wind Damage
Page 13 of 14 Reference (a)
Curved Roof Temporary Repairs
Page 14 of 14 Reference (a)
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| Slide Number 10 |
| Slide Number 11 |
| Slide Number 12 |
| Slide Number 13 |
| Slide Number 14 |
File details come from the government source that posted it. Updated .