This document is a reference file containing facility information and photographs for Building #5 (Gymnasium) located at USCG Base Elizabeth City in North Carolina, with Real Property Unique Identifier (RPUID) #24032.

The gymnasium is a two-story structure with a 26-foot interior ceiling height on the second floor, featuring a main gym space measuring 109 feet by 49 feet. The building contains administrative offices, mechanical rooms, bathrooms, a kitchen/food service area, and associated support spaces. The facility has experienced significant wind damage to its curved roof section, with temporary repairs currently in place consisting of blue tarpaulin coverings. Interior damage includes sheetrock replacement with plywood in affected areas. The building is accessed via multiple gates on the USCG Base and is situated near the Pasquotank River. Photographs document the building's exterior views from four directions (north, east, west, and south), interior gymnasium views, roof conditions before and after wind damage, and temporary repair efforts. The facility measurements indicated in the plan view are noted as approximate.

View the file

Other files

File Type Posted
Building 5 Drawing.pdf PDF
70Z08126QELIZ0008 QA.pdf PDF
SF-1442.pdf PDF
SF25A Payment Bond.pdf PDF
SF25 Performance Bond.pdf PDF
Clauses and Provisions.pdf PDF
B5 Roof Repair SOW.pdf PDF
Wage Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Page 1 of 14 Reference (a)

Pasquotank River

Back Gate

Front Gate

Page 2 of 14 Reference (a)

26 Ft. Interior Ceiling Height

Building# 5 - Gymnasium

Page 3 of 14 Reference (a)

Real Property Unique Identifier (RPUID)# - 24032

Front – North Side

Page 4 of 14 Reference (a)

East Side

Page 5 of 14 Reference (a)

West Side

Page 6 of 14 Reference (a)

Rear - South Side

Page 7 of 14 Reference (a)

24032

Gym View #1

Page 8 of 14 Reference (a)

Gym View #2

Page 9 of 14 Reference (a)

Interior View – Sheetrock Replaced with Plywood

Page 10 of 14 Reference (a)

Flat Roof View

Page 11 of 14 Reference (a)

Curved Roof View BEFORE Wind Damage

Page 12 of 14 Reference (a)

Curved Roof Wind Damage

Page 13 of 14 Reference (a)

Curved Roof Temporary Repairs

Page 14 of 14 Reference (a)

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10
Slide Number 11
Slide Number 12
Slide Number 13
Slide Number 14