USCG AIR STATION SITKA ANNUAL BACK-FLOW PREVENTER INSPECTION
Solicitation number
70Z04524QKODI0019
Issued by

About this file

This solicitation is for annual backflow prevention system inspection services. The U.S. Coast Guard is seeking quotes for inspection of backflow prevention systems at the USCG Air Station Sitka located at 611 Airport Road in Sitka, Alaska. Quotes are due no later than 1:00pm Alaska Time on January 17, 2024 and shall be submitted to the contracting officer via email. The inspection services shall be completed by February 15, 2024. This acquisition is set aside exclusively for small businesses. The primary point of contact for questions is the named contracting specialist and work will be performed at the listed Coast Guard air station location.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Back Flow Form

Anchorage Water & Wastewater Utility Attn: Field Services 3000 Arctic Blvd. Anchorage, AK 99503-3813 Phone: (907) 564-2762

FAX: (907)786-5001

EMAIL: awwufieldservices@awwu.blz

Service Type

Existing New Replacement

Replaces SN# Serial Number MOA # 017295 Assembly ID Contact Name Test Due Date Tim Logan

Assembly Location Information Facility Name Location ID USCG Sitka Service Address Zip Phone 611-Airport Road 99835 (907)942-7562

Property Information Mailing Name Same Address 1

City ST Zip Telephone

Assembly Information Type Size Mfr Model RP 3/4 Watts LF909 QT RPZ

Equip Location Club boiler room

Hazard Type Domestic

Water Turn Off Authorization: (Print) Time

03:17:14 PM

Is the Assembly installed in accordance with manufacturers recommendations and/or local codes? Yes No

Test Date 10/25/2022 https://mydoforms.appspot.com/

Initial Test

Pass Fail

Reduced Pressure Principal Assembly Check Valve #1 Check Valve #2 Relief Valve

Held at 8.1 PSID Held at PSID Opened at 3.4 PSID

Closed Tight Leaked

Closed Tight Leaked

Did Not Open

Pressure Vacuum Breaker Air Inlet Check Valve

Opened at PSID Held at PSID Did Not Open Leaked

Repairs and Materials Used

Final Test

Pass

Reduced Pressure Principal Assembly Check Valve #1 Check Valve #2 Relief Valve

Held at PSID Held at PSID Opened at PSID

Closed Tight Closed Tight

Pressure Vacuum Breaker Air Inlet Check Valve

Opened at PSID Held at PSID

Test Gauge Used:

Manufacturer/Model: SN: Calib/Accur Date:

Midwest 07143561

Remarks

Photos

Image 1 Image 2

Image 3 Image 4

Image 5 Image 6

Image 7 Image 8

Image 9 Image 10

Service Restored Yes No

The above is certified to be true at the time of testing Tester Name Company Name Steve Sizemore IV North Star Fire Protection, LLC Company Address Phone Number 520 W. 58th Ave. Unit G Anchorage, AK 99518 (907)677-1233 Tester Signature Certified Tester #

BAT 723

Customer Email

Other Email

Powered by www.doForms.com https://mydoforms.appspot.com/imageViewer?blobKey=ag9zfm15ZG9mb3Jtcy1ocmRyFwsSCmJsb2Jfc3RvcmUYgICMkKWc8QoM&blobName=9a856g853r3oft0$$05042020162136$$Published$$458$$P1$$P1.jpg https://mydoforms.appspot.com/imageViewer?blobKey=ag9zfm15ZG9mb3Jtcy1ocmRyFwsSCmJsb2Jfc3RvcmUYgICM0Imu8QoM&blobName=9a856g853r3oft0$$05042020162136$$Published$$458$$S1$$S1.jpg https://www.doForms.com

File details come from the government source that posted it. Updated .