7-Spec Sheet-HY6G.pdf

PDF 253 KB Posted

Attached to
Alpine School District Nutrition Equipment Bid Spring 2026
Solicitation number
ASD04162026KWR
Issued by
Utah County, Utah

About this file

This specification sheet details equipment requirements for the Alpine School District Nutrition Equipment Bid Spring 2026, a procurement initiative for the Alpine School District in Utah. The document specifies a Groen Model HY-6G stainless steel pressureless steamer as one of the required gas-fired units. The steamer features 6-pan capacity with twin atmospheric 45,000 BTU/hr gas steam generators for a total of 90,000 BTU maximum input. Key specifications include all-stainless steel construction with removable panels for maintenance access, field-reversible insulated doors with magnetic switches, and a wide drip sink with condensate drain. The unit accommodates various pan sizes including 12 x 20 x 1" (6 pans per cavity), 12 x 20 x 2½" (3 pans per cavity), and 12 x 20 x 4" (2 pans per cavity). The steamer reaches operational readiness in 8-10 minutes under normal conditions and includes a 60-minute mechanical timer with continuous steam setting, auto-delime functionality, and NSF-listed certification to ANSI Z83.11 standards. The equipment is designed and manufactured in the United States by Unified Brands.

Installation requirements include natural or propane gas service via ½" NPT pipe, two ¾" NH cold water supply lines, a 1¼" O.D. free venting drain, and 115-volt single phase, 4 AMP electrical service. The manufacturer recommends water treatment using a PureSteem softening system when total dissolved solids exceed 30-40 parts per million and pH ranges outside 7.0-9.0. Optional accessories include flanged feet kits, caster kits, and single water connection modifications. The specification sheet was revised as of March 17, 2017, with product information available through the manufacturer's website at unifiedbrands.net or by phone at 888-994-7636.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NAME:

LOCATION:

ITEM NO:

QTY:

MODEL NO:

AIA NO:

SIS NO:

HYPERSTEAM PRESSURELESS STEAMER

6-Pan capacity stainless steal pres-sureless steamer, with twin gas atmospheric steam generators in cabinet base. (model HY-6G shown)

HyPerSteam 140797 RevD

Revised 03/17

CONSTRUCTION: Steamer cavities and cabinet base shall be all stainless steel construction with removable right side panel providing access to internal components.

Steamer doors are all stainless steel, with strong continuous hinge and is field-reversible for left or right-swing. Doors shall be insulated and provided with a one piece, replaceable seal. Easy-open handle and latch shall provide positive lock and seal when door is pushed or slammed shut. Hidden magnetic door switch cuts power to blower and cuts power to generator when the door is opened. Pan support racks shall be polished stainless steel and removable for easy cleaning. Wide drip sink with condensate drain is positioned under cavity doors. 21 5/8” wide cabinet base shall have stainless steel frame with removable front, side and back panels standard. Cabinet base shall be provided with 6” legs with adjustable bullet feet.

FINISH: Cabinet exterior including door shall be finished to a #3 uniform finish. Cavity interiors are polished stainless steel. Control panel face plates shall be smudge resistant polyester film, ensuring maximum ease in cleaning and maintaining an attractive appearance.

C.S.A. DESIGN CERTIFICATION: Steamer shall be C.S.A. (formerly A.G.A.) design-certified to ANSI Z83.11.

SANITATION: Unit shall be designed and manufac-tured to meet NSF codes and be NSF-listed. Unit shall allow operator to delime both steam generators through access ports on top of unit without tools or service call. Push button auto-DELIME is standard.

CONTROLS: Steamer cavity controls shall include an ON-OFF power touch pad; 60 minute mechanical timer, with continuous steam setting; and READY light which indicates when cavity is ready for steaming. Auto-DELIME button initi-ates deliming cycle.

PERFORMANCE FEATURES: Each steamer cavity shall have a powerful side-mounted blower, which increases steam velocity and provides efficient steam distri-bution throughout cavity and between loaded pans. Steam generators deliver approximately 15,000 BTUs/hour input

Steamer shall be a Groen Model HY-6G stainless steel pressureless steamer with twin atmospheric 45,000 BTU/hr gas steam generators, for total of 90,000 BTU maximum.

CABINET MOUNTED GAS MODEL HY-6G

1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net Please reference our website for the most updated product information and specifications.

per 2 1/2” deep steam pan. Heat up time to READY shall be 8-10 minutes, under normal conditions. Cavities are kept warm and ready for instant steam between loads.

No cavity warm up required, after READY light comes on.

DELIME indicator light warns operator of need to delime generator. Unit will shut off if water level is low. When power is turned off, unit automatically blows down the steam generator, to reduce sediment build-up.

CABINET BASE STEAM SOURCE: Unit shall have twin gas heated cabinet mounted steam gen-erators to provide atmospheric steam to the chambers at a temperature of approximately 212° F. Each steam generator has an electric water sensor, a 45,000 BTU/hr firing rate. Unit comes standard with standing pilot with electronic ignition system.

PAN CAPACITY :

Pan Size/Type Per cavity Total

12 x 20 x 1” 6 12

12 x 20 x 2 1/2” 3 6

12 x 20 x 4” 2 4

INSTALLATION: Unit requires gas service (specify natural or propane) via 1/2” NPT pipe or approved equiv-alent. Unit requires two 3/4” NH cold water supply lines;

and 1-1/4” O.D. free venting drain; and 115 volt single phase, 4 AMP electric service. A second cold water con-nection is provided for the spray condenser.

WATER SUPPLY REQUIREMENTS: To minimize service problems a PureSteem water treatment (softening) system is recommended when water quality is found to exceed limits stated below and in operator manual. Recommended MINIMUM water quality stan-dards are: Total dissolved solids (TDS) content should have a value of 30 to 40 parts per million, and the water pH should be 7.0 to 9.0

ORIGIN OF MANUFACTURE: Designed and manufactured in the United States.

OPTIONS/ACCESSORIES:

Flanged feet kit
Caster kit
Single water connection

(cold water)

888-994-7636, unifiedbrands.net © 2018 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.