7-3202600039 Attachment 7 Project Drawings.pdf
PDF 4 MB Posted
- Attached to
- RFP 3202600039 CCRC Backup Generator
- Solicitation number
- 3202600039
- Issued by
- Travis County, Austin City, Texas
About this file
This is a project drawings attachment for a backup generator installation project at the Texas Workforce Commission's Criss Cole Rehabilitation Center located at 4800 North Lamar Boulevard in Austin, Texas. The drawings package includes plumbing and electrical specifications and details for the installation of a 400 kilowatt natural gas-powered generator with associated infrastructure. The project involves new natural gas piping from an existing meter to the generator equipment, installation of a pressure regulator system located a minimum of 3 feet from all electrical equipment within the mechanical yard, and complete electrical interconnection including underground and overhead conduit routing from the generator pad to the main electrical room. The natural gas piping specifications include Schedule 40 metallic pipe with maximum developed lengths of 59 linear feet for 5 PSI pressure systems and 100 linear feet for low-pressure systems below 2 PSI, with support requirements every 5 feet using hot-dipped galvanized or stainless steel fasteners. Electrical work includes installation of a new automatic transfer switch (ATS) rated at 1400 amperes, proper grounding and bonding systems compliant with NEC standards, conduit systems with compression connections, and comprehensive labeling and identification of all circuits and equipment.
The project documentation specifies that the contractor must coordinate with Austin Energy for a scheduled utility outage prior to demolition and new work, with key contact Elizabeth Kasprowicz at the Austin Energy Key Account Manager office. The electrical design is based on peak demand load analysis showing 344 kilowatt-hours with an additional 25 percent buffer for new loads, totaling 430 kilovolt-amperes and 1,194 amperes at 208 volts three-phase. The generator specifications include Cummins equipment with weather-protective, sound-attenuated Level 2 enclosure rated at 75 decibels at 23 feet, vertical discharge configuration, natural gas fuel type, and full accessory packages including fuel filters, lube oil filters, air intake filters, coolers, transfer pumps, and priming pumps. All materials and installation must comply with applicable plumbing and electrical codes including the 2023 National Electrical Code, NFPA standards, ASME standards, and local authority having jurisdiction requirements. The contractor is responsible for testing and commissioning all systems, providing temporary construction power and lighting, maintaining functionality of existing building systems, and conducting short circuit coordination studies and arc flash hazard analysis with calculated labels per NFPA 70E.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLUMBING ABBREVIATIONS
DESCRIPTION AAB DESCRIPTION AAB
ABOVE CEILING A/C LAVATORY LAV
ABOVE FINISHED FLOOR AFF MAN HOLE MH
ABOVE GRADE. GROUND AG MAXIMUM MAX
ACCESS PANEL AP MECHANICAL MECH
ACRYLONITRILE BUTADIENE STYTENE ABS MINIMUM MIN
AIR ADMITTANCE VALVE AAV MIXING VALVE MV
ARCHITECT ARCH MOP SINK MS
AUTHORITY HAVING JURISDICTION AHJ NORMALLY CLOSED NC
BACKFLOW PREVENTER BFP NORMALLY OPEN NO
BELOW FINISHED FLOOR BFF NOT IN CONTRACT NIC
BELOW FLOOR B/F NOT TO SCALE NTS
BELOW GRADE/ GROUND BG EXISTING TO BE PROTECTED IN PLACE (P)
BELOW SLAB B/S POLYETHYLENE PE
BOTTOM OF PIPE BOP POLYETHYLENE CROSS-LINKED PEX
BRAKE HORSEPOWER BHP POLYVINYL CHLORIDE PVC
BRITISH THERMAL UNIT BTUH POLYVYLIDENE FLOURIDE/ DIOFLOURIDE PVDF
BTUH ( THOUSANDS ) MBH POUND LB
CAST IRON CI POUNDS PER SQUARE INCH PSI
CELCIUS C POUNDS PER SQUARE INCH ABSOLUTE PSIA
CHILLED WATER RETURN CHWR POUNDS PER SQUARE INCH GAUGE PSIG
CHILLED WATER SUPPLY CHWS PRESSURE DROP PD
CHLORINATED POLYVINYL CHLORIDE CPVC PRESSURE REDUCING VALVE PRV
CLEANOUT CO PUMP, BOOSTER BP
CLEANOUT, FLOOR FCO PUMP, CHILLED WATER CHWP
CLEANOUT, GRADE GCO PUMP, CIRCULATION CP
CLEANOUT, GRADE TWO-WAY DGCO PUMP, HOT WATER HWP
CLEANOUT, WALL WCO REDUCED PRESSURE ZONE RPZ
CLEANOUT, YARD YCO EXISTING TO BE RELOCATED (R)
CLEANOUT, YARD TWO-WAY DYCO REVOLUTION PER MINUTE RPM
CONDENSER RETURN CWR SCHEDULE SCH
CONDENSER SUPPLY CWS SHOWER SH
COPPER CU SINK SK
CUBIC FEET CF SQUARE FEET SF
CUBIC FEET PER HOUR CFH STRUCTURAL STRUC
CUBIC FEET PER MINUTE CFM TEMPERATURE TEMP
EXISTING TO BE DEMOLISHED/ REMOVED (D) TEMPERATURE, ENTERING WATER EWT
DEGREE D TEMPERATURE, LEAVING WATER LWT
DIAMETER DIA THERMOSTATIC MIXING VALVE TMV
DRAIN, AREA AD TOP OF PIPE TOP
DRAIN, FLOOR FD TRAP PRIMER TP
DRAIN, ROOF PRIMARY RD TYPICAL TYP
DRAIN, ROOF SECONDARY SRD ULTRAVIOLET UV
ELECTRICAL ELEC UNDERGROUND UG
ELEVATION ELEV UNIT, AIR HANDLING AHU
EXISTING EXIST, (E) UNIT, FAN COIL FC
FAHRENHEIT F UNLESS NOTED OTHERWISE UNO
FAT, OIL, AND GAS FOG UP/ DOWN UP/DN
FOOT/ FEET FT VACUUM BREAKER VB
FEET PER MINUTE FPM VALVE FLOW COEFFICIENT CV
FEET PER SECOND FPS VENT THRU ROOF VTR
FIXTURE UNIT FU WATER GAUGE WG
FLEXIBLE FLEX WATER CLOSET WC
FLOOR FLR WATER HAMMER ARRESTOR WHA
FLOOR SINK FS WATER, OIL, AND GAS WOG
FUTURE (F)
GALLON GAL ELECTRICAL
GALLONS PER HOUR GPH VOLTAGE V, VOLT
GALLONS PER MINUTE GPM WATTAGE W, WATT
HEAD IN FEET FTHD KILOWATT KW
HEAD IN INCHES WATER COLUMN INWC PHASE PH
HEATING HOT WATER RETURN HWR AMPERE A, AMP
HEATING HOT WATER SUPPLY HWS
HEATING, VENTILATION, AIR CONDITIONING HVAC
HORSEPOWER HP
HOUR HR
HUB DRAIN HD
INCHES PER HOUR IN/HR
INDIRECT DRAIN/ RECEPTOR ID
INDIRECT WASTE IW
INVERT ELEVATION IE
WATER SYSTEMS
SYSTEM TYPE ABBV LINE TYPE
NATURAL GAS SYSTEMS
LOW PRESSURE GAS (LESS THAN 2 PSI)
MEDIUM PRESSURE GAS ( 2PSI - 5 PSI)
HIGH PRESSURE GAS (GREATER THAN 5 PSI)
LIQUID GAS
SYSTEM TYPE ABBV LINE TYPE
HPG
MPG
G
LG
PLUMBING PIPE TYPES
UNION, SCREWED
VCR FITTING WITH CAP
TEE, OUTLET DOWN
REDUCER, ECCENTRIC
FLANGE JOINT
REDUCER, CONCENTRIC
ELBOW, TURN-UP
ELBOW, TURN-DOWN
INDICATES TIE-IN BETW. EXIST. AND NEW
PIPE CAP
BLIND FLANGE
CAPPED TEE
PIPE FITTINGS
UNION, FLANGED
BALL JOINT
PLUGGED PIPE
COUPLING (JOINT)
CROSSING
TEE
TEE, OUTLET UP
P-TRAP
HIGHER PIPE
LOWER PIPE
BFP
BALL
DIAPHRAGM
GAS COCK
GATE
BALANCING
GLOBE
PLUG
PRESSURE REDUCING
PRESSURE RELIEF
QUICK OPENING
CHECK
SPRING CHECK
SWING CHECK
BALL CHECK
GAUGE COCK
PRESSURE-TEMPERATURE RELIEF
ALARM CHECK
BACK FLOW PREVENTER,
DOUBLE CHECK TYPE
PLUMBING VALVES
S
THERMOMETER WELL ONLY
THRUST BLOCK
TEST PLUG
STRAINER, WYE
STRAINER W/ BLOW DOWN
PITCH OF PIPE, RISE (R) OR DROP (D)
PRESSURE GAUGE AND COCK
PRESSURE SWITCH
METER
FLOW METER, VENTURI
FLOW SWITCH
FLOW METER, INSERTION
FLEX CONNECTION
FLOWMETER, ORIFICE
EXPANSION LOOP
FILTER
EXPANSION JOINT
AIR VENT, AUTOMATIC W/SERVICE VALVE
ANCHOR
AIR VENT, AUTOMATIC W/SERVICE VALVE
ALIGNMENT GUIDE (PIPE SLEEVE)
AIR VENT, MANUAL
PIPING SPECIALITIES
PURGE PORT
F
FM
F
M
P
TB
TOP TO BOTTOM
1"-CW
1"-HW
1"-DI
1"-HWR
PIPING IDENTIFIED FROM
TOP TO BOTTOM
PLUMBING TAGS
PIPING IDENTIFIED FROM
LEFT TO RIGHT
PIPING IDENTIFIED FROM
1"-HWR
1"-HW
1"-DI
1"-CW
1"-HWR
1"-HW
1"-DI
1"-CW
X-1TYPE/MARK (SEE SCHEDULE)
PLUMBING EQUIPMENT/FIXTURE TAGS
CODE AND REGULATORIES ABBREVIATIONS
DESCRIPTION AAB DESCRIPTION AAB
AMERICAN NATIONAL STANDARDS ANSI NATIONAL ELECTRICAL CODE NEC
AMERICAN SOCIETY OF CIVIL ENGINEERS ASCE NATIONAL FIRE PROTECTION ASSOCIATION NFPA
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND
AIR-CONDITIONING ENGINEERS
ASHRAE UNIFORM BUILDING CODE UBC
AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASME UNIFORM FIRE CODE UFC
AMERICAN SOCIETY OF PLUMBING ENIGNEERS ASPE UNIFORM PLUMBING CODE UPC
AMERICAN SOCIETY OF SANITARY ENGINEERING ASSE UNDERWRITERS LABORATORIES UL
AMERICAN SOCIETY OF TESTING AND MATERIALS ASTM
AMERICAN WATER WORKS ASSOCIATION AWWA
CAST IRON SOIL PIPE INSTITUTE CISPI
FACTORY MUTAL FM
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS IEEE
INTERNATIONAL ASSOCIATION OF PLUMBING AND
MECHANICAL OFFICIALS
IAPMO
INTERNATIONAL BUILDING CODE IBC
INTERNATIONAL ENERGY CONSERVATION CODE IECC
INTERNATIONAL FIRE CODE IFC
INTERNATIONAL FUEL GAS CODE IFGC
INTERNATIONAL MECHANICAL CODE IMC
INTERNATIONAL PLUMBING CODE IPC
INTERNATIONAL RESIDENTIAL CODE IRC
GENERAL PLUMBING SYMBOLS
REVISION NUMBER - SHOWN ON PLANS
POINT WHERE NEW CONNECTS TO EXISTING
NUMBER OF DETAIL ON SHEET
NUMBER OF SHEET WHERE DETAIL APPEARS
KEYNOTE
CONTINUATION SYMBOL
ROOM NAME AND NUMBER
ITEM TO BE DEMOLISHED
AREA NOT IN CONTRACT
PIPE SIZE TAG (DIAMETER)
ABOVE GROUND PIPING
BELOW GROUND PIPING
PIPE INVERT ELEVATION TAG
EXISTING PIPE TAG
PIPING BEING DEMOLISHED
PIPE SLOPE TAG
INVERT: -105'- 0" 127/128"
1/8" / 12" SLOPE
2"
(E)
Room
7300 FM 2222 #2
Austin, Texas 78730-2314 USA
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole
Rehabilitation
Center
Generator
4800 N.Lamar
Blvd. Austin, TX.
78756
24-1053.00
P0.0
PLUMBING GENERAL NOTES &
SYMBOLS
PLUMBING SHEET INDEX
P0.0 PLUMBING GENERAL NOTES & SYMBOLS
P3.0 PLUMBING PLAN
P5.0 PLUMBING DETAILS
1. CONTRACTOR SHALL REVIEW AND ADHERE TO ALL NOTES LOCATED IN THE MEP SHEET
SET.
2. PROVIDE PIPING MATERIALS AND FACTORY-FABRICATED PIPING PRODUCTS OF SIZES,
TYPES, PRESSURE RATINGS, AND CAPACITIES AS INDICATED. WHERE NOT INDICATED,
PROVIDE PROPER SELECTION AS DETERMINED BY INSTALLER TO COMPLY WITH
INSTALLATION REQUIREMENTS. PROVIDE SIZES, AND TYPES MATCHING PIPING AND
EQUIPMENT CONNECTIONS; PROVIDE FITTINGS OF MATERIALS WHICH MATCH PIPE
MATERIALS USED IN SOIL, AND VENT PIPING SYSTEMS.
3. NOT ALL PIPE SIZES ARE SHOWN ON PLANS FOR CLARITY. REFER TO RISER DIAGRAMS
FOR PIPING SIZES.
4. COORDINATE FIRE ALARM CONNECTIONS TO FIRE PROTECTION SYSTEM WITH FIRE
PROTECTION CONTRACTOR.
5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING
PIPE, JOINTS, OR CONNECTED EQUIPMENT.
6. SLEEVE FOUNDATION BEAM PENETRATIONS WITH SCH. 40 STEEL PIPE SLEEVE OF 2"
LARGER DIAMETER.
7. GAS PIPING:
a. FURNISH AND INSTALL A GAS COCK, DIRT LEG, AND UNION CONNECTION AT EACH
PIECE OF EQUIPMENT.
b. SUPPORT PIPING EVERY 5 FEET, AS REQUIRED BY OWNER, AS DETAILED ON
DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT.
c. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF
THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES.
d. GAS PIPING INSTALLED IN RETURN AIR PLENUMS OR BURIED BELOW BUILDING
INTERIOR CONCRETE SLABS SHALL BE SLEEVED AND VENTED TO ATMOSPHERE IN
ACCORDANCE WITH ALL CODES.
e. GAS PIPING EXPOSED TO EXTERIOR SHALL BE PAINTED WITH 2 COATS OF YELLOW
BITUMINOUS BASED RUST-INHIBITING PAINT.
f. ALL BUILDING INTERIOR MOUNTED PRESSURE REGULATOR SHALL BE OPD TYPE AND
VENTED TO ATMOSPHERE. UTILIZE MAXITROL; 325-L SERIES LINE PRESSURE
REGULATORS WITH OPD.
GENERAL PLUMBING NOTES:
Digitally Signed
Mark Mikulin, PE (TX)
2025.12.04 10:35:11-06'00'
NATURAL
GAS METER
(E) 2" HG
(E) 3" MG
(E
3" M
G
1 1/4" MG 4" G
GENERATOR GEN-1
PLUMBING NOTES
A. FIELD VERIFY SIZES OF ALL MAINS, BRANCHES, AND VALVES PRIOR TO
ORDER AND INSTALLATION.
B. CONTRACTOR TO VERIFY EXISTING GAS SERVICES ARE NOT AFFECTED BY
GENERATOR ADDITION. EXISTING GAS FLOW RATES TO REMAIN AS
EXISTING.
C. NATURAL GAS TO BE INSTALLED 1'-0" MINIMUM ABOVE FINISHED FLOOR OF
MECHANICAL YARD.
D. DO NOT ANCHOR SUPPORTS IN MORTAR. ANCHOR ONLY IN BRICK OR CMU.
E. NATURAL GAS SUPPORTS AND FASTNERS TO BE HOT DIPPED GALVANIZED
(NOT ELECTRO-GALVANIZED, ZINC PLATED, ETC.) OR STAINLESS STEEL.
F. PAINT ALL NEW, MODIFIED, OR REPLACED PIPING TO MATCH EXISTING.
PAINT ALL EXPOSED PIPING WITH A RUST INHIBITOR PAINT TO PREVENT
EXTERIOR PIPE RUSTING DUE TO MOISTURE AND CHEMICALS.
7300 FM 2222 #2
Austin, Texas 78730-2314 USA
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole
Rehabilitation
Center
Generator
4800 N.Lamar
Blvd. Austin, TX.
78756
24-1053.00
P3.0
PLUMBING PLAN
1/8" = 1'-0"P3.0
1 PLUMBING PLAN
NEW WORK KEYNOTES
1 NEW NATURAL GAS METER TO BE PROVIDED AND INSTALLED BY UTILITY SERVICE
PROVIDER. CONTRACTOR TO PROVIDE NEW GAS REGULATOR AND ACCESSORIES
DOWNSTREAM OF THE GAS METER. REFER TO DETAIL 1 / P5.0 FOR GAS RISER
DIAGRAM.
2 LOCATE PRESSURE REGULATOR(S) A MINIMUM OF 3-FT FROM ALL ELECTRICAL
EQUIPMENT WITHIN THE MECHANICAL YARD.
GAS
NATURAL GAS
(5 PSI OR LESS)
2" AND BELOW
STD WT BLACK CARBON STEEL ASTM
A53 GRADE B
TYPE E OR S
CL. 150 MALLEABLE IRON
ASTM A197, ASME B16.3
THREADED
N/A
BA-2
EXPOSED EXERIOR GAS PIPING SHALL BE PAINTED WITH RUST-
INHIBITING PAINT.
3" AND ABOVE
BUTTWELD: STD WT CS
ASTM A234, ASME B16.9
BUTTWELD PER ASME B31.9 FOR BUILDING
SERVICES PIPING
GA-1
SCHEDULE NOTES
1. ALL PLUMBING MATERIALS TO MEET PLUMBING CODE REQUIREMENTS.
2. PROVIDE PRODUCT LISTED OR ENGINEER PRE-APPROVED EQUAL, APPLIES TO ALL PRODUCTS LISTED IN SCHEDULE.
3. INSTALL ALL PRODUCTS PER THE MANUFACTURERS RECOMMENDATIONS.
4. ALL PIPING IS TO BE SUPPORTED PER ANSI B31.9, ASME B31.1, MSS SP-58 AND MSS SP-69 AND MANUFACTURER'S INSTRUCTIONS.
5. CLEAN AND FLUSH ALL NEWLY INSTALLED PIPING AND STRAINER / FILTERS WITH SYSTEM APPROPRIATE MATERIAL PRIOR TO PUTTING SYSTEM INTO OPERATION.
6. PVC, CPVC AND CAST IRON PIPE AND FITTINGS SHALL BE BY CHARLOTTE PIPE OR EQUAL.
7. PVC SHALL NOT TO BE USED IN THE FOLLOWING LOCATIONS:
A. HVAC PLENUMS OR IN EXTERIOR LOCATIONS WHERE EXPOSED TO SUNLIGHT; COATINGS OR WRAPS ARE NOT ALLOWED IN THESE LOCATIONS.
B. DOMESTIC WATER SUPPLY SYSTEMS INSIDE OF THE BUILDING.
8. PIPING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE APPLICABLE CODES AND LOCAL AHJ.
9. WHEN JOINING DISIMILAR METALS USE DIELECTRIC NIPPLES OR COUPLINGS, OR DIELECTRIC FLANGE KITS ON LARGER PIPING. DIELCTRIC UNIONS ARE NOT ALLOWED.
PLUMBING PIPE SCHEDULE
PIPING ID SERVICE SIZE MATERIAL TYPE FITTING TYPE JOINT TYPE INSULATION TYPE VALVES REMARKS
Digitally Signed
2025.12.04 10:35:22-06'00'
7300 FM 2222 #2
Austin, Texas 78730-2314 USA
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole
Rehabilitation
Center
Generator
4800 N.Lamar
Blvd. Austin, TX.
78756
24-1053.00
P5.0
PLUMBING DETAILS
TABLE 1215.2(6) [UPC 2021]
SCEDULE 40 METALLIC PIPE [NFPA 54: TABLE 6.2.1(g)]
GAS: NATURAL
INLET PRESSURE: 5.0 PSI
PRESSURE DROP: 3.5 PSI
TOTAL DEVELOPED LENGTH: 59 LF
PIPE SIZE
(INCHES)
MAXIMUM FLOW
(CFH)
1/2 1,300
3/4 2,630
1 4,800
1-1/4 9,960
1-1/2 14,800
2 28,500
2-1/2 45,400
3 80,200
4 164,000
TOTAL HORIZONTAL PIPING = 45 FT
TOTAL VERTICAL PIPING = FT
SUBTOTAL PIPING LENGTH = FT
ADD FOR FITTINGS= 25% FT
TOTAL DEVELOPED LENGTH = FT
12" = 1'-0"P5.0
2 NATURAL GAS RISER DIAGRAM - DEMO
12" = 1'-0"P5.0
1 NATURAL GAS RISER DIAGRAM - NEW WORK
TABLE 1215.2(1) [UPC 2021]
SCEDULE 40 METALLIC PIPE [NFPA 54: TABLE 6.2.1(b)]
GAS: NATURAL
INLET PRESSURE: LESS THAN 2 PSI
PRESSURE DROP: 0.5 IN.WC.
TOTAL DEVELOPED LENGTH: 100 LF
PIPE SIZE
(INCHES)
MAXIMUM FLOW
(CFH)
1/2 50
3/4 104
1 195
1-1/4 400
1-1/2 600
2 1,160
2-1/2 1,840
3 3,260
4 6,640
Digitally Signed
2025.12.04 10:35:37-06'00'
A AMPERE
AC ABOVE COUNTER
AFF ABOVE FINISHED FLOOR
AIC AMP INTERRUPTING CAPACITY
A/V AUDIO VISUAL
ATS AUTOMATIC TRANSFER SWITCH
BLDG BUILDING
C CONDUIT
CKT CIRCUIT
CM CONTROL MODULE
CONN CONNECT OR CONNECTION
CT CURRENT TRANSFORMER
DIM DIMENSION
EA EACH
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
ELEC ELECTRIC, ELECTRICAL
EMER EMERGENCY
EPO EMERGENCY POWER OFF
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FLA FULL LOAD AMPS
FS FLOW SWITCH
FSD FIRE SMOKE DAMPER
GC GENERAL CONTRACTOR
GFI GROUND FAULT INTERRUPTER
GND GROUND
HOA HAND-OFF-AUTO
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HTR HEATER
J-BOX JUNCTION BOX
KCM THOUSAND CIRCULAR MILLS
ELECTRICAL ABBREVIATIONS LIST
LOTO LOCK OUT TAG OUT
LTG LIGHT OR LIGHTING
MCB MAIN CIRCUIT BREAKER
MC MOTOR CONTROL CENTER
MCP MOTOR CIRCUIT PROTECTOR
MIN MINIMUM
MH METAL HALIDE
MLO MAIN LUGS ONLY
MNS MASS NOTIFICATION SYSTEM
MRS MOTOR RATED SWITCH
MSB MAIN SWITCH BOARD
MTD MOUNTED
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
N.I.C. NOT IN CONTRACT
NL NIGHT LIGHT (UNSWITCHED)
NTS NOT TO SCALE
∅ PHASE
OL OVERLOAD
OE OVER HEAD ELECTRIC
PS PULL STRING
RECPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
SPD SURGE PROTECTION DEVICE
TS TAMPER SWITCH
TYP. TYPICAL
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
V VOLTAGE
WH WATER HEATER
WP WEATHER PROOF
WR WEATHER RATED
XFMR TRANSFORMER
ELECTRICAL EQUIPMENT CLEARANCE REQUIREMENTS
KEYED NOTES:
3' (0-150V TO GND),
3.5' (151V-600V TO GND), 4'
(OVER 150V WITH EXPOSED
LIVE PARTS ON OTHER
SIDE).
DEDICATED EQUIPMENT
SPACE SHALL BE KEPT
CLEAR TO 6FT ABOVE
EQUIPMENT OR TO
STRUCTURE OF ALL BUT
CONDUIT SERVING
EQUIPMENT.
MIN OFFSET SHALL BE
DEPTH OF EQUIPMENT ON
PERPENDICULAR WALL
ELECTRICAL
EQUIPMENT
ELECTRICAL
EQUIPMENT
WORKING
SPACE XFMR
30"
MIN
DOOR
WIDTH
MINUS 3"
ES
DH
3/ 4"
3/ 4"
3/ 4"
3/ 4"
1"
S
TO LTG/PANEL
TO DOOR OPERATOR
TO PLENUM, EXCEPT TO IT CLOSET
WHERE CEILING IS EXPOSED TO
DECK OR INACCESSIBLE
TO FACP
TO CONTACTOR
48" 1.
2.
REFER TO RCP FOR CEILING TYPES IN
ALL AREAS.
PRIORITY FOR PROXIMITY TO DOOR
SHALL BE AS SHOWN.
3"
18"
3/ 4"
1/
4"
1- 2"
, 1 -1
AV1
2"
TO FLOORBOX
TO PANEL
TO PLENUM. TO IT CLOSET
WHERE CEILING IS EXPOSED
TO DECK OR INACCESSIBLE.
TO PLENUM, EXCEPT TO AV
EQUIP. WHERE CEILING IS
EXPOSED TO DECK OR
INACCESSIBLE.
EXIT
6"
TV TV
3/ 4" 2"
60"
BACKSPLASH
AC AC
4"
FIRE
FIRE ALARM
PULL DOWN
SIMPLEX
WALL MNT TV
VERIFY TV HT
BEFORE
INSTALL AND
CENTER
OUTLETS
BEHIND TV
4"
80"
MINIMUM
CLEARANCE
TO CEILING
6"
CLEARANCE
TO CEILING
SHALL HAVE
PRIORITY
OVER 80"
ABOVE
FINISHED
FLOOR
MIN HT TO
BOTTOM
OF
NOTIFICATION
APPLIANCES
OS
8"
MAX12'-0"
MINIMUM
CLEARANCE
TO CEILING
NAMEPLATE REQUIREMENTS
ELECTRICAL PANELS EQUIPMENT CONTROLS
1.
2.
3.
4.
5.
SPECIFICATIONS
NAMEPLATE: 1/16" PHENOLIC PLASTIC LAMINATE, TWO FLAT HEAD
SCREWS
FINISHED AREA WIRING DEVICES: ADHESIVE LABELS, CLEAR W/ BLACK
TEXT
J-BOXES: USE PERMANENT INK MARKER AND PAINT AS NOTED
OUTDOOR AND HARSH ENVIRO WIRING DEVICES: MARKER ON INSIDE OF
COVER
IN PUBLIC AREAS SUCH AS LOBBIES, CONF. ROOMS, ETC, LABEL INSIDE
OF RECEPTACLE COVERS AND EXPOSED JBOX COVERS USING MARKER.
PLACE A DOT OF PAINT ON OUTSIDE OF SPECIAL SYSTEMS BOXES.
RECEPTACLES J-BOXES
PNL # CKT
PWR IT FIRE
NO
PAINT
ORANGE
COVER
RED
COVER
L1#1 120V
COM FA
NAC
PANEL L1
208/120V, 3PH, 4W
225A, FED FROM H1
VIA XFMR T-L1
CWP-VFD
208/120V, 3PH, 4W
5HP, FED FROM L1
CLNG
J
J
SINGLE RECEPTACLE
DUPLEX RECEPTACLE
SPLIT CONTROLLED DUPLEX RECEPTACLE
CONTROLLED DUPLEX RECEPTACLE
WALL MOUNTED JUNCTION BOX
CEILING MOUNTED JUNCTION BOX
MULTIOUTLET ASSEMBLY
SAFETY DISCONNECT SWITCH (NON-FUSED)
SAFETY DISCONNECT SWITCH (FUSED)
M MOTOR RATED TOGGLE SWITCH
P POWER POLE (OPEN OFFICE STYLE)
UTILITY SERVICE POWER POLE
T30
TRANSFORMER. THE TRANSFORMER TYPE IS
INDICATED BY A NUMBER INDICATING KVA RATING
FOLLOWING THE UPPER CASE LETTER "T"
POWER DEVICE LEGEND
SPECIAL RECEPTACLE
FB1 FLOORBOX (SEE FLOORBOX SCHEDULE)
ELECTRICAL PANELBOARD
FLOOR CLEARANCE AREA
USB RECEPTACLE
QUADPLEX RECEPTACLE
FLOOR MOUNTED DUPLEX RECEPTACLE
FLOOR MOUNTED QUADPLEX RECEPTACLE
CEILING DUPLEX RECEPTACLE
COMBINATION MOTOR STARTER (FUSED)
EMERGENCY POWER OFF BUTTON
TCS
OS
LIGHTING CONTROLS LEGEND
LIGHT SWITCH
LIGHT SWITCH WITH INTEGRAL OCCUPANCY SENSOR
CELING MOUNTED OCCUPANCY SENSOR
CELING MOUNTED DAYLIGHT SENSOR
A LIGHTING CONTROL TAG
(SEE LIGHTING CONTROL MATRIX)
CELING MOUNTED PHOTOCELL
TOUCHSCREEN CONTROL STATION
OS
DS
PC
PC
DS
OS WALL MOUNTED OCCUPANCY SENSOR
WALL MOUNTED DAYLIGHT SENSOR
WALL MOUNTED PHOTOCELL
AV1
SPECIAL SYSTEMS DEVICES
VOICE/DATA OUTLET
TELEPHONE OUTLET
CEILING VOICE/DATA OUTLET
DATA OUTLET
CEILING OUTLET
AUTO PUSH DOOR BUTTON
ELECTRIC STRIKE
MAGNETIC LOCK
CARD READER
SECURITY KEYPAD
CLNG
CLNG
ML
ES
CR
TV DATA OUTLET
1V2D
# OF VOICE AND # OF DATA OUTLETS.
EXAMPLE: 1V2D = 1 VOICE, 2 DATA
# OF DATA OUTLETS
TV
WIRELESS ACCESS POINT
AUDIO VIDEO INPUT JACK BOX
ELECTRICAL SYMBOL NOTES
LOWERCASE LETTER INDICATED LIGHTING
ZONE (WHERE APPLICABLE)
A d P1#1
EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES
CEILING MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S).
ARROW INDICATES DIRECTIONAL ARROW ON ILLUMINATED FACE(S).
AE DIAGONAL HATCH INDICATES EMERGENCY/EGRESS LIGHTING AND/OR
TAGGED WITH "E" (AS IN "AE")d
P1#1
CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD CONDITIONS
CONDUIT IN FLOOR
1 REVISION NUMBER - SHOWN ON PLANS
NUMBER OF DETAIL ON SHEET
NUMBER OF SHEET WHERE DETAIL APPEARS
1 KEYED NOTE (SEE SCHEDULE)
Room
6 ROOM NAME AND NUMBER
NEW
EXISTING TO BE REMOVED/RELOCATED
EXISTING TO REMAIN
ITEM TO BE
REMOVED
GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL SYMBOLS.
a
SWITCHING INSTRUCTIONS
LOWER CASE LETER DESIGNATES A
SWITCHLEG, LETTER WILL BE SHOWN NEXT TO
EACH FIXTURE CONTROLLED BY SWITCH
SPECIFICATION NOTES:
2 = DOUBLE POLE
3 = THREE WAY
4 = FOUR WAY
D = DIMMER
EP = EXPLOSION PROOF
K = KEY OPERATED
T = TIMER
AC
MOUNTING REQUIREMENTS
48" = MOUNT AT 48 INCHES ABOVE FINISHED FLOOR
AC = MOUNT ABOVE COUNTER 4" ABOVE BACK-SPLASH
(MOUNT AT 18 INCHES ABOVE FINISH FLOOR U.N.O.)
SPECIFICATION NOTES:
GFI = INTEGRAL GROUND FAULT TRIP MODULE
IG = ISOLATED GROUND
MG = MARINE GRADE
TL = TWIST-LOCK
TR = TAMPER-RESISTANT
WP = WEATHER RESISTANT RECEPTACLE WITH
METAL WEATHERPROOF WHILE IN USE COVER
GFI
FIXTURE TYPE ID (SEE LIGHT FIXTURE SCHEDULE)
PANEL NAME & CIRCUIT NUMBER
M
ELECTRICAL ONE LINE SYMBOLS
MOLDED CASE/ THERMAL MAGENTIC CIRCUIT BREAKER
FUSED DISCONNECT SWITCH
FUSE, HOLDER & PULLER
GROUND
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
UTILITY METER
SURGE PROTECTION DEVICE
X MOTOR, "X" INDICATING HORSE POWER
AUTOMATIC TRANSFER SWITCH
ST SHUNT TRIP (K=KIRK KEY INTERLOCK, RT=REMOTE TRIP)
K KIRK-KEY
DRAWOUT CIRCUIT BREAKER, AIR TYPE
DRAWOUT CIRCUIT BREAKER, VAC TYPE
THERMAL OVERLOAD
NON-FUSED DISCONNECT SWITCH
SPD
6"
OS
CR F FAA
ELECTRICAL SHEET INDEX
E0.0 ELECTRICAL SYMBOLS AND LEGENDS
E0.1 ELECTRICAL GENERAL NOTES
E0.2 ELECTRICAL GENERAL NOTES
E1.0 EQUIPMENT SCHEDULES
E3.0 ELECTRICAL PLANS
E5.0 ELECTRICAL ONE-LINE
7300 FM 2222, Bldg. 2, Ste. 2 Austin, Texas 78730-2314 USA
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole Rehabilitation
Center Generator
4800 N.Lamar Blvd. Austin, TX.
78756
24-1053.00
E0.0
ELECTRICAL SYMBOLS AND
LEGENDS
1.1. SPECIAL SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, TELECOMMUNICATIONS, FIRE
ALARM, AUDIO/VIDEO, ACCESS CONTROL SYSTEMS.
1.2. FOR SPECIAL SYSTEMS EQUIPMENT AND DEVICES SHOWN ON THE CONSTRUCTION
DOCUMENTS, OR EQUIPMENT AND DEVICES THAT CAN BE REASONABLY IMPLIED AS
REQUIRED TO OPERATE ITEMS SHOWN, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR POWER, RACEWAY/BOX/ENCLOSURES ROUGH-IN, AND INFRASTRUCTURE PROVISION
EVEN IF SAID SPECIAL SYSTEMS ARE PROVIDED BY A SPECIALIST CONTRACTOR, OWNER'S
AGENT, OR UNDER SEPARATE CONTRACT.
1.3. TELECOMMUNICATIONS: IT CABLING, JACKS, EQUIPMENT RACKS, NETWORKING
EQUIPMENT, AND PATCH PANELS WILL BE PROVIDED AND INSTALLED BY TELECOM
CONTRACTOR. ALL OTHER WORK BY ELEC. CONTRACTOR.
1.4. FIRE ALARM: CONTROL PANELS, MODULES, NOTIFICATION APPLIANCES, INITIATING
DEVICES, WIRING, BATTERIES, AND MISC. MATERIALS SHALL BE PROVIDED BY
SPECIALIST FIRE ALARM CONTRACTOR UNDER THIS CONTRACT.
1.5. AUDIO/VIDEO: COORDINATE SCOPE WITH OWNER PRIOR TO BID.
1.6. ACCESS CONTROL (SECURITY): COORDINATE SCOPE WITH OWNER PRIOR TO BID.
1.7. COORDINATE REQUIREMENTS FOR DATA ROOMS WITH OWNER'S INFORMATION
TECHNOLOGIES REPRESENTATIVE (IT REP).
1.8. AT MINIMUM, THE FOLLOWING GENERAL PROVISIONS SHALL BE PROVIDED BY THE
CONTRACTOR. ADDITIONAL ITEMS SPECIFIED ELSEWHERE ON THE CONSTRUCTION
DOCUMENTS:
1.8.1. DOUBLE GANG DEVICE BOX WITH SINGLE GANG REDUCER (AS NEEDED) AT
EACH LOCATION SHOWN ON PLANS. NOTE THAT SOME SPECIAL SYSTEMS EQUIPMENT
MAY REQUIRE A DIFFERENT SIZE BOX. COORDINATE LOCATIONS AND SIZES FOR
BOXES WITH RESPECTIVE SPECIALIST CONTRACTORS PRIOR TO ROUGH-IN.
1.8.2. CONDUIT WITH PULL STRINGS FROM SOURCE (TELEPHONE BACKBOARD,
SECURITY PANEL, FACP, ETC) OR ACCESSIBLE CEILING SPACE TO ALL DEVICE
LOCATIONS SHOWN ON THESE PLANS. HOMERUN CONDUITS MAY BE COMBINED
WHERE APPROVED BY SPECIALIST CONTRACTOR. COORDINATE CONDUIT SIZES WITH
RESPECTIVE SPECIALIST CONTRACTORS PRIOR TO INSTALLATION.
1.9. POWER LIMITED AND NON POWER LIMITED CABLE SHALL NOT SHARE COMMON
RACEWAYS OR ENTER JUNCTION BOXES THROUGH THE SAME OPENING.
SPECIAL SYSTEMS NOTES:
2025.12.04 10:35:55-06'00'
7300 FM 2222, Bldg. 2, Ste. 2
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole Rehabilitation
Center Generator
4800 N.Lamar Blvd. Austin, TX.
78756
24-1053.00
E0.1
ELECTRICAL GENERAL NOTES
CODE REQUIREMENTS
THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF LAWS, RULES, REGULATIONS, CODES STANDARDS, AND ORDINANCES OF FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION, AND ALL EQUIPMENT AND MATERIALS SHALL COMPLY WITH SAID AUTHORITIES WHETHER INDICATED ON THE CONTRACT
DOCUMENTS OR NOT.
1. ALL WORK SHALL BE PERFORMED PER:
1.1. 2023 NATIONAL ELECTRICAL CODE - NEC
1.2. NATIONAL FIRE PROTECTION ASSOCIATION - NFPA
2. THE PUBLICATIONS AND STANDARDS OF THE FOLLOWING AUTHORITIES, IN ADDITION TO THOSE SPECIFIED IN RELATED SUPPLEMENTARY CONDITIONS, SHALL BE OBSERVED DURING CONSTRUCTION AND ARE REFERENCED IN THE DOCUMENTATION BY THE ABBREVIATIONS NOTED:
2.1. UNITED STATES OF AMERICA STANDARDS INSTITUTE - USASI
2.2. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS - IEEE
2.3. NATIONAL ELECTRICAL CODE - NEC
2.4. NATIONAL FIRE PROTECTION ASSOCIATION - NFPA
2.5. UNDERWRITER'S LABORATORY - UL
2.6. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION - NEMA
2.7. CERTIFIED BALLAST MANUFACTURERS - CBM
2.8. AMERICAN SOCIETY FOR TESTING AND MATERIALS - ASTM
2.9. OCCUPATIONAL SAFETY AND HEALTH ACT - OSHA
3. U.N.O., EQUIPMENT AND DEVICES SHALL BE MOUNTED PER ADA AND TAS REQUIREMENTS.
3.1. OPERABLE DEVICES (SWITCHES, CARD READERS, ETC) AT OR BELOW 48" AFF
3.2. RECEPTACLES, TELEPHONE AND DATA OUTLETS AT 18" AFF (15" MIN TO BOTTOM OF DEVICE), UNO
SCOPE OF WORK
1. THE SCOPE OF WORK SHALL INCLUDE COMPLETE PROVISIONS FOR ELECTRICAL POWER DISTRIBUTION TO ALL LIGHTING, DEVICES, APPLIANCES, AND EQUIPMENT SHOWN
ON THE CONSTRUCTION DOCUMENTS.
1.1. PROVISIONS INCLUDE, BUT ARE NOT LIMITED TO, ALL SUPPLIES, MATERIALS, EQUIPMENT, TOOLS AND LABOR.
1.2. PROVISIONS ALSO INCLUDE ALL MISCELLANEOUS MATERIALS REQUIRED TO COMPLETE THE WORK SHOWN INCLUDING, BUT NOT LIMITED TO, SUPPORTS, HANGERS, RACEWAYS, BOXES, SLEEVES, SEALS, EQUIPMENT PADS, WIRING CONNECTORS, TERMINALS, LABELS, SIGNS, AND MARKERS.
1.3. THE CONSTRUCTION DOCUMENTS INCLUDE ALL PLANS, ELEVATIONS, DETAILS, DIAGRAMS, SCHEDULES, AND NOTES ON THE DRAWINGS AND THE WRITTEN
SPECIFICATIONS INCLUDING ANY ITEMS MENTIONED IN EITHER THE SPECIFICATIONS OR ON THE DRAWINGS BUT NOT IN THE OTHER.
1.4. WHERE USED ON THE PLANS AND IN THE SPECIFICATIONS AND WHERE NOT SPECIFICALLY NOTED OTHERWISE, THE TERM "PROVIDE" AND THE TERM "INSTALL"
SHALL MEAN FURNISH, INSTALL, CONNECT AND TEST.
1.5. UNLESS EXPLICITLY NOTED "BY OTHERS" OR "EXISTING", ALL ITEMS SHOWN GRAPHICALLY OR SPECIFIED BY NOTES AND DETAILS ON THE PLANS SHALL BE
FURNISHED, INSTALLED, CONNECTED, AND TESTED AS NEEDED.
2. ADDITIONALLY, THE SCOPE OF WORK SHALL INCLUDE:
2.1. APPLICATION FOR TEMPORARY AND PERMANENT ELECTRICAL SERVICE, PERMITTING, INSPECTION, AND PAYMENT OF ALL ASSOCIATED FEES.
2.2. TESTING AND COMMISSIONING OF ELECTRICAL SYSTEMS.
2.3. EQUIPMENT RENTAL.
2.4. TEMPORARY CONSTRUCTION POWER AND LIGHTING.
2.5. PROVISIONS FOR MAINTAINING THE FUNCTIONALITY OF EXISTING TO REMAIN BUILDING COMMUNICATIONS, FIRE ALARM, SECURITY/ACCESS CONTROL, PUBLIC
ADDRESS, AND BELL SYSTEMS THAT WILL BE AFFECTED BY THE WORK.
2.6. SHORT CIRCUIT COORDINATION STUDY AND ARC FLASH HAZARD ANALYSIS WITH CALCULATED LABELS PER NFPA 70E.
SUBMITTALS
1. PRODUCT DATA: SUBMIT CATALOG DATA SHOWING MANUFACTURER'S NAME AND CONTACT INFORMATION, ALL STANDARD FEATURES, AMPERAGE, VOLTAGE, AIC RATINGS, DIMENSIONS, WEIGHTS, LISTINGS & PRODUCT LABELS, MATERIAL TYPES, FINISHES AND CLEARLY INDICATING WHICH OPTIONAL FEATURES WILL BE PROVIDED.
1.1. WHERE MULTIPLE SIZES ARE LISTED, INDICATE SIZES TO BE USED.
1.2. WHERE MULTIPLE PRODUCTS ARE SHOWN ON THE SAME PAGE, INDICATE WHICH PRODUCTS TO BE USED.
2. SHOP DRAWINGS (WHERE APPLICABLE): MANUFACTURER OR CONTRACTOR PREPARED DRAWINGS SHOWING ALL RELEVANT DIMENSIONS, WEIGHTS, ELECTRICAL & MECHANICAL CONNECTION REQUIREMENTS, CONDUIT ENTRY POINTS, ASSEMBLY REQUIREMENTS, LIFTING REQUIREMENTS, LIFTING POINTS, REQUIRED CLEARANCES.
INCLUDE PLAN VIEWS & ELEVATIONS.
2.1. INCLUDE ALL RELEVANT ELECTRICAL DIAGRAMS INCLUDING SCHEMATIC AND INTERCONNECTION DIAGRAMS FOR POWER, SIGNAL, AND CONTROL WIRING.
COORDINATION
1. ALL POWER OUTAGES SHALL BE COORDINATED IN WRITING WITH OWNER SEVEN (7) BUSINESS DAYS (MIN) PRIOR TO THE OUTAGE. COORDINATE SHUT-DOWN OF
UTILITIES WITH UT PM AND FACILITY SERVICES.
2. COOPERATE FULLY WITH THE OWNER OR THEIR REPRESENTATIVE DURING CONSTRUCTION OPERATIONS TO MINIMIZE CONFLICTS AND TO FACILITATE OWNER USAGE SO
AS NOT TO INTERFERE WITH THE OWNER'S OPERATIONS.
3. THE DRAWINGS ARE DIAGRAMMATIC. THEY DO NOT SHOW SWITCHES, POWER AND DATA OUTLETS, SPECIAL SYSTEMS COMPONENTS (FA, ACCESS CONTROL, A/V, ETC), ELECTRICAL EQUIPMENT, EQUIPMENT CONNECTIONS, REQUIRED RACEWAY, ETC. IN THEIR EXACT DIMENSIONED LOCATIONS. THE CONTRACTOR MUST CAREFULLY REVIEW THE ARCHITECTURAL, STRUCTURAL MECHANICAL, PLUMBING, FIRE PROTECTION, AND SPECIAL SYSTEMS PLANS TO IDENTIFY CONFLICTS AND AREAS THAT
REQUIRE COORDINATION.
4. COORDINATE ELECTRICAL AND SPECIAL SYSTEMS EQUIPMENT ROUGH-IN WITH FURNITURE, MILLWORK, SIGNS, MECHANICAL AND PLUMBING SYSTEMS, SPRINKLER SYSTEMS, ARCHITECTURAL AND STRUCTURAL ELEMENTS, AND THE OWNER'S REPRESENTATIVE. MINOR CHANGES IN ELECTRICAL EQUIPMENT LOCATIONS AND LAYOUT THAT ARE REQUIRED BY SITE CONDITIONS OR ORDERED BY THE DESIGN TEAM PRIOR TO PERFORMANCE OF WORK SHALL BE MADE BY THE CONTRACTOR WITHOUT
ADDITIONAL CHARGES TO THE OWNER .
5. MAINTAIN REQUIRED NEC WORKING SPACE AND DEDICATED EQUIPMENT SPACE AROUND ALL ELECTRICAL EQUIPMENT, CONTROLS PANELS, ETC THAT ARE SUBJECT TO MAINTENANCE, TESTING, OR USER INTERFACE. COORDINATE WITH OTHER TRADES. IF CLEARANCE CANNOT BE PROVIDED, THE CONTRACTOR SHALL NOTIFY THE
ENGINEER PRIOR TO ROUGH-IN.
6. COORDINATE COLOR SELECTIONS FOR LUMINAIRES AND ALL DEVICE PLATES WITH ARCHITECT.
7. COORDINATE POWER REQUIREMENTS FOR HVAC CONTROLS, FIRE ALARM, SECURITY, AND OTHER SPECIAL SYSTEMS TO MAKE SURE THAT ALL WORK IS COVERED IN THE
BID.
8. CONTACT UT EHS TO DISPOSE OF THE FOLLOWING WASTE FROM RENOVATION; SILVER TIPPED FLORESCENT LIGHT BULBS (REMOVED INTACT), ALL BALLASTS NOT LABELED “NO PCBS”, MERCURY CONTAINING THERMOSTATS, SMOKE DETECTORS AND EXIT SIGNS THAT CONTAIN RADIOACTIVE MATERIAL. CONTRACTOR TO BUY DOT APPROVED CONTAINERS, PLACE WASTE IN CONTAINERS AND USE UT WASTE TAGS FOR EACH CONTAINER. COMPLETE REQUEST FOR DISPOSAL (UT EID REQUIRED) AND
SUBMIT TO EHS.
QUALIFICATIONS
1. MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING PRODUCTS SHOWN ON THE CONSTRUCTION DOCUMENTS WITH MINIMUM THREE YEARS DOCUMENTED
EXPERIENCE.
2. INSTALLER: A STATE LICENSED ELECTRICIAN WITH DOCUMENTED EXPERIENCE INSTALLING ALL EQUIPMENT SPECIFIED HERE IN SHALL DIRECTLY SUPERVISE ALL WORK.
WHERE NOTED IN THE SPECIFICATIONS, REQUIRED BY CODE, OR REQUIRED BY THE MANUFACTURER, INSTALLER SHALL BE A MANUFACTURER TRAINED AND/OR
CERTIFIED INSTALLER OF THE SPECIFIC PRODUCT TO BE INSTALLED.
3. WHERE TESTING IS REQUIRED BY THE CONSTRUCTION DOCUMENTS, EQUIPMENT MANUFACTURER, OR CODE; TESTING SHALL BE PERFORMED BY AN AGENCY WITH DOCUMENTED EXPERIENCE AND PROPERLY CALIBRATED, FULLY FUNCTIONING EQUIPMENT, THAT IS A MEMBER OF THE INTERNATIONAL ELECTRICAL TESTING ASSOCIATION, MANUFACTURER CERTIFIED, OR IS A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), AND IS ACCEPTABLE TO THE AUTHORITY HAVING
JURISDICTION.
QUALITY ASSURANCE
1. UNLESS OTHERWISE APPROVED, ALL EQUIPMENT SHALL BE NEW, PROPERLY DESIGNED, FROM A REPUTABLE MANUFACTURER MEETING THE SPECIFICATION QUALIFICATIONS, IN COMPLIANCE WITH THE SPECIFICATION REQUIREMENTS, AND IN FULL WORKING ORDER.
2. WHERE TWO OR MORE ITEMS OF THE SAME CLASS OF EQUIPMENT ARE REQUIRED, THESE ITEMS SHALL BE PRODUCTS OF A SINGLE MANUFACTURER; HOWEVER, THE COMPONENT PARTS OF THE ITEM NEED NOT BE THE PRODUCTS OF THE SAME MANUFACTURER UNLESS STATED IN THE TECHNICAL SECTION.
3. LISTING AND LABELING: WHERE REQUIRED, ALL ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION AND MARKED FOR THE INTENDED USE. TESTING AGENCY SHALL BE UL UNLESS
NOTED OTHERWISE OR PRE-APPROVED BY OWNER AND AHJ.
4. ALL EQUIPMENT USED FOR TESTING SHALL BE IN FULL WORKING ORDER AND CALIBRATED PER THE MANUFACTURER'S RECOMMENDATIONS.
GENERAL ELECTRICAL REQUIREMENTS:
IDENTIFICATION
1. PROVIDE APPROPRIATE LABELS AND WARNING SIGNS FOR ALL EQUIPMENT, WIRING DEVICES, CONDUCTORS, CABLES, BOX, AND ENCLOSURES. PROVIDE BURIED
DETECTABLE WARNING TAPE FOR UNDERGROUND CONDUITS.
2. CONDUCTOR TAGGING: TAG ALL CONDUCTORS AT MOTOR CONTROLS, PANELS, TERMINAL CABINETS AND JUNCTION BOXES. TAG CIRCUITS WHICH PASS THROUGH
OTHER DEVICES SUCH AS LIGHTING CONTACTORS.
3. PROVIDE A TYPED PANEL DIRECTORY FOR EACH PANEL PROVIDED OR MODIFIED FOR THIS PROJECT. DIRECTORY SHALL IDENTIFY THE CIRCUIT NUMBER, LOADS SERVED, AND LOCATION OF LOADS BY ROOM NUMBER. MOUNT ON INSIDE OF EACH PANEL AND FILE THEM WITH THE OWNER WHEN THE WORK IS COMPLETED.
4. PROVIDE EACH PANEL WITH A MANUFACTURER PREPARED ARC FLASH HAZARD WARNING LABEL.
5. ALL ELECTRICAL EQUIPMENT SHALL BE IDENTIFIED BY MEANS OF 3"X1" (MIN)NAMEPLATES PERMANENTLY ATTACHED TO THE EQUIPMENT, PLATES SHALL BE METAL, PLASTIC, OR SIMILAR, BLACK WITH 1/4"h (MIN) ENGRAVED WHITE LETTERS.
6. JUNCTION AND PULL BOXES SHALL BE LABELED WITH PANEL NAME, CIRCUIT #, AND VOLTAGE.
7. RECEPTACLES SHALL BE LABELED WITH THE PANEL NAME AND CIRCUIT #. USE WHITE LABELS WITH BLACK TEXT. RECEPTACLES IN LOBBIES AND OTHER "HIGH END"
AREAS SHALL BE LABELED BEHIND THE FACEPLATE.
8. FIRE ALARM, EMERGENCY/CRITICAL PWR, LIFE SAFETY LABELS, INCLUDING RECEPTACLES, SHALL BE COLOR CODED & ENGRAVED.
GENERAL REQUIREMENTS
1. THE CONTRACTOR SHALL PROVIDE CONCRETE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT. THE CONCRETE SHALL PROTRUDE 3" PAST THE EDGE OF THE ELECTRICAL EQUIPMENT ON ALL SIDES. THE CONCRETE PAD SHALL BE 6" TALL AND CONTAIN A 1/2" CHAMFER ON ALL SIDES. PROVIDE A MINIMUM OF 3000
PSI CONCRETE AND #4 REBAR.
2. ALL TERMINALS, LUGS AND BUS JOINTS SHALL BE TIGHTENED PER THE MANUFACTURER'S TORQUE RECOMMENDATIONS.
3. NO FOREIGN SYSTEMS SUCH AS PIPING, DUCT WORK, ETC SHALL BE INSTALLED ABOVE ELECTRICAL EQUIPMENT.
4. PROVIDE SLEEVES FOR PENETRATIONS THROUGH WALLS/FLOORS. SEAL ALL OPENINGS. USE FIRE-RATED SEALANT FOR OPENINGS IN RATED WALLS.
5. PERFORM GROUND PENETRATING RADAR SCAN BEFORE CUTTING EXISTING STRUCTURES. COORDINATE LOCATIONS WITH STRUCTURAL ENGINEER/ARCHITECT.
CONDUCTORS AND CABLES
1. ALL BUILDING WIRING SHALL BE INSULATED COPPER CONDUCTORS RUN FROM LOAD TO SOURCE INSIDE RACEWAY, CONTINUOUS (WITHOUT SPLICES) BETWEEN JUNCTION
AND PULL BOXES, AND EXPOSED INSIDE PANELS ONLY.
2. ALL SINGLE POLE CIRCUITS SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR ROUTED TO THE SOURCE PANEL.
3. FIELD VERIFY WHETHER A NEUTRAL IS REQUIRED FOR ALL TWO AND THREE POLE CIRCUITS. FOR ALL LOADS EXCEPT MOTORS, A NEUTRAL IS ASSUMED TO BE REQUIRED
UNLESS FIELD DETERMINED TO BE UNNECESSARY.
4. ALL POWER & CONTROL WIRING ROUTED THROUGH RETURN AIR PLENUMS SHALL BE PLENUM RATED.
5. UP TO 3-20A CIRCUITS MAY SHARE A RACEWAY FOR HOMERUNS WHERE SUITABLE & PER NEC CONDUIT FILL RULES.
6. 120V, 20A. HOME RUNS LONGER THAN 100' AND 277V, 20A. HOME RUNS LONGER THAN 150' SHALL BE #10 MIN.
GROUNDING AND BONDING
1. ALL RACEWAYS AND CIRCUITS SHALL BE PROVIDED WITH A NEC 250 COMPLIANT GREEN GROUND CONDUCTOR.
2. ALL EQUIPMENT SHALL BE PROPERLY BONDED.
3. UPON COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL INSTALLATION SHALL BE MEGGER TESTED AND PROVED TO BE FREE OF UNWANTED GROUNDS AND
OTHER DEFECTS.
4. ROUTING OF GROUNDING ELECTRODE CONDUCTORS SHALL BE IN METAL CONDUIT IN ALL LOCATIONS THAT ARE SUBJECT TO PHYSICAL ABUSE OR ENVIRONMENTAL
DETERIORATION SUCH AS EXTERIOR MOUNTED, EXPOSED BELOW LAY IN CEILING, ETC.
HANGERS AND SUPPORTS
1. SUPPORT RACEWAYS USING GALVANIZED STEEL OR MALLEABLE IRON STRAPS; CHANNEL OR PIPE CLAMPS AS APPROPRIATE.
2. PROVIDE SUPPORTS AT ALL BOXES, ELEC. EQUIP., LOADS, & AT CODE REQUIRED INTERVALS ALONG RACEWAYS.
3. GROUP RELATED RACEWAYS AND SUPPORT USING STEEL CHANNEL CONDUIT RACKS WITH 25% SPARE CAPACITY.
4. SUPPORT LTG, ELEC. EQUIP., RACEWAYS/BOXES, ETC. INDEPENDENTLY. DO NOT USE CEILING SUPPORT WIRES, PIPING SYSTEMS, ETC.
RACEWAY AND BOXES
1. PROVIDE COMPLETE RACEWAY SYSTEMS FROM SOURCE TO ALL LOADS WITH DEDICATED SUPPORTS FOR EACH RACEWAY ELEMENT.
2. PROVIDE ALL REQUIRED BOXES & SUPPORTS FOR WIRING DEVICES, TELECOMMUNICATIONS, FIRE ALARM, ACCESS CONTROL, CONTROLS EQUIPMENT, ALARMS, SENSORS, ETC.
3. PROVIDE PULL BOXES AT APPROPRIATE LOCATIONS FOR ALL POWER AND SPECIAL SYSTEMS RACEWAYS WHETHER SHOWN ON PLANS OR NOT. INSTALL IN CONCEALED, ACCESSIBLE LOCATIONS.
4. DO NOT INSTALL RACEWAY WITH MORE THAN THE EQUIVALENT OF THREE NINETY DEGREE BENDS BETWEEN PULL POINTS.
5. THE CONDUIT ROUTING SHOWN ON THESE PLANS IS DIAGRAMMATIC.
6. COORDINATE INTERIOR ROUTING WITH OTHER TRADES; STRUCTURE; NEW AND EXISTING UTILITIES, DUCTWORK, PIPING; AND OTHER EXISTING CONDITIONS AS REQUIRED
FOR A COMPLETE, CONFLICT FREE INSTALLATION.
7. COORDINATE SITE ROUTING WITH OTHER TRADES; STRUCTURE; NEW AND EXISTING BURIED UTILITIES, PAVED AREAS, CONDUIT SLEEVES, AND LANDSCAPING BEFORE
DIGGING TO AVOID CONFLICTS, DAMAGE, AND TO ALLOW FOR FUTURE INSTALLATIONS.
8. ROUTE RACEWAYS PARALLEL AND PERPENDICULAR TO WALLS, FLOORS, AND CEILINGS.
9. ROUTE EXPOSED CONDUIT PARALLEL AND TIGHT TO STRUCTURAL ELEMENTS. FOLLOW ALL SURFACE CONTOURS; DO NOT ROUTE IN FREE AIR FROM POINT TO POINT.
10. INSTALL RACEWAYS SO THAT IT DRAINS TO JUNCTION AND PULL BOXES TO AVOID MOISTURE TRAPS AT LOW POINTS; INSTALL JUNCTION BOX WITH DRAIN FITTING AT LOW
POINTS IN CONDUIT SYSTEM.
11. INSTALL FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE RACEWAY CROSSES SEISMIC, CONTROL, AND EXPANSION JOINTS.
12. INSTALL SUITABLE PULL STRING OR CORD IN EACH EMPTY RACEWAY, LABEL, AND CAP.
13. CLOSE ENDS AND UNUSED OPENINGS IN SURFACE RACEWAYS, WIREWAY, BOXES, AND ENCLOSURES.
14. WHERE POSSIBLE, ALL CONDUIT ROUTED THROUGH ROOF STRUCTURE SHALL SHARE COMMON PENETRATIONS AS MECHANICAL DUCTWORK OR PIPING. COORDINATE
WITH MECHANICAL CONTRACTOR.
15. ALL ROOF AND WALL PENETRATIONS SHALL BE FLASHED AND SEALED TO MAINTAIN THE FIRE RATING AND WATERPROOFING OF THE STRUCTURE PER THE
MANUFACTURER OF THE MATERIAL'S RECOMMENDED PRACTICES.
16. USE MULTI-GANG BOXES IN ALL POSSIBLE LOCATIONS.
17. PAINT EXPOSED RACEWAYS AND BOXES TO MATCH THE SURFACE TO WHICH THEY ARE ATTACHED.
18. ALL CONDUIT SHALL HAVE AN NEC COMPLIANT GROUND AND AN INSULATED THROAT BUSHING IN PLACE FOR PULLING CONDUCTORS.
19. ALL CONNECTIONS TO MOTORS, INSTRUMENTS, MACHINES, AND EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE MADE USING LIQUID-TIGHT, FLEXIBLE
METAL CONDUIT (LFMC), (3FT MAX).
INSTALLATION:
DELIVERY AND STORAGE
1. STORE ALL ELECTIRCAL/SPECIAL SYSTEMS EQUIPMENT/MATERIALS IN CLEAN, DRY SPACE LOCATED ABOVE GRADE. PROTECT FROM DIRT, WATER, CONSTRUCTION
DEBRIS, TRAFFIC, FREEZE, AND DETERIORATION FROM SUN LIGHT.
2. MAINTAIN FACTORY WRAPPING OR PROVIDE APPROPRIATE COVER FOR ALL LARGE ELECTRICAL EQUIPMENT. FOLLOW ALL MANUFACTURER RECOMMENDATIONS FOR
HUMIDITY AND MAX/MIN TEMPERATURES FOR STORING ELECTRICAL EQUIPMENT.
GENERAL ELECTRICAL REQUIREMENTS:
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole Rehabilitation
Center Generator
4800 N.Lamar Blvd. Austin, TX.
78756
24-1053.00
E0.2
ELECTRICAL GENERAL NOTES
WIRING DEVICES
1. DUPLEX RECEPTACLES MOUNTED ON OPPOSITE SIDES OF A COMMON WALLS SHALL BE A MINIMUM OF 12" APART. (NO BACK TO BACK OUTLETS) TO REDUCE NOISE TRANSFER, JUNCTION BOXES IN ADJACENT ROOMS SHALL NOT BE INSTALLED IN THE SAME WALL CAVITY. SEPARATE ALL JUNCTION BOXES BY AT LEAST ONE FRAMING
MEMBER.
2. PROVIDE GFI RECEPTACLES & DIMMERS WITH DEDICATED NEUTRALS INDEPENDENT OF OTHER LOADS ON THE CIRCUIT.
ENCLOSED SWITCHES AND CONTACTORS
1. TO FACILITATE SAFE REPAIR AND REPLACEMENT OF EQUIPMENT, PROVIDE ALL STARTERS AND DISCONNECTS WITH LOTO PROVISIONS.
2. MOUNT STARTERS AND DISCONNECTS SERVING HVAC EQUIPMENT TO STRUCTURE ADJACENT TO EQUIPMENT SERVED RATHER THAN MOUNTING DIRECTLY TO THE EQUIPMENT. THIS INCLUDES U-CHANNEL SUPPORT AND 120V MAINTENANCE RECEPTACLE FOR ROOF MOUNTED EQUIPMENT. PROVIDE WORKING SPACE PER NEC
REQUIREMENTS.
LIGHTING
1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LIGHT FIXTURE LOCATIONS AND QUANTITIES.
2. EXAMINE THE AREA OF INSTALLATION TO VERIFY ADEQUATE SPACE AND MOUNTING PROVISIONS ARE PROVIDED FOR THE SPECIFIED LUMINAIRE PRIOR TO ORDERING
LUMINAIRES.
3. VERIFY THAT LUMINAIRES WILL NOT INTERFERE WITH REQUIRED CLEARANCES FOR EQUIPMENT INCLUDING FILTER PULL SPACE, NEC WORKING SPACE IN FRONT OF
DISCONNECTS, CONTROL PANELS, ETC.
4. COORDINATE EXIT LIGHT LOCATIONS WITH STRUCTURE AND BUILDING SYSTEMS TO INSURE EXIT SIGNS ARE VISIBLE.
5. PROVIDE GROUND WIRE AND ONE NEUTRAL CONDUCTOR PER CIRCUIT IN ALL LIGHTING CONDUIT.
6. LABEL ALL CIRCUIT BREAKERS SERVING EMERGENCY LIGHTING.
7. UNO, ALL EXIT SIGNS, EMERGENCY EGRESS PATHWAY LIGHT FIXTURES, LIGHTS NOTED "xE", AND LIGHTS SHOWN CROSS HATCHED SHALL BE CONNECTED TO THE SWITCHED AREA LIGHTING CIRCUIT FOR NORMAL OPERATION AND AN UNSWITCHED CIRCUIT FROM THE SAME OCPD TO AUTOMATICALLY CONTROL POWER TRANSFER TO AN INTEGRAL BATTERY PACK FOR 90 MINUTES OF EMERGENCY OPERATION WHEN LOSS OF NORMAL POWER IS SENSED ON THE UNSWITCHED CIRCUIT. PROVIDE A BATTERY
STATUS INDICATOR MOUNTED IN A VISIBLE LOCATION.
8. INSTALL FIXTURES PLUMB, SQUARE AND LEVEL WITH CEILINGS AND WALLS AND SECURE FIXTURES PER MANUFACTURER'S PRINTED INSTRUCTIONS.
9. ADJUST AIMABLE FIXTURES, CLEAN, AND PROVIDED ALL FIXTURES WITH LAMPS PRIOR TO OWNER OCCUPANCY.
10. U.N.O., LIGHTING SWITCHES IN ROOMS SHALL CONTROL ONLY FIXTURES IN THAT ROOM.
11. WHEN MORE THAN ONE(1) LIGHTING SWITCH IS SHOWN AT A LOCATION THEY SHALL BE GANGED TOGETHER.
12. LUMINAIRE WHIPS MAY BE FMC, 6FT MAX. SECURE TO STRUCTURE USING LISTED SUPPORTS.
13. EXIT SIGNS WITH BACKWARD LETTERING SHALL NOT BE PERMITTED ANYWHERE. SINGLE-SIDED EXIT SIGNS SHALL HAVE A BLANK BACK SIDE.
DOUBLE-SIDED EXIT SIGNS SHALL HAVE ENGLISH LETTERS "E X I T" THAT READ FROM LEFT-TO-RIGHT ON EACH SIDE.
LIGHTING CONTROL REQUIREMENTS
1. OCCUPANCY SENSOR OFF DELAY SHALL BE SET BY EC AT END OF PROJECT TO 20 MINUTES. AMBIENT LIGHT OVERRIDE SHALL BE SET SUCH THAT THE LUMINAIRES ARE SWITCHED OFF WHEN APPROPRIATE FC LEVEL IS MEASURED ON THE FLOOR (REGARDLESS OF THE FOOTCANDLES MEASURED AT THE OCCUPANCY SENSOR).
2. INSTALL DIMMER SWITCHES ON THE LOAD SIDE OF OCCUPANCY SENSORS AND OTHER CONTROLS.
GENERAL REQUIREMENTS
1. COMPLIANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF PROVIDING EQUIPMENT THAT IS NEW, PROPERLY DESIGNED, FROM A REPUTABLE MANUFACTURER, AND IN FULL WORKING ORDER.
2. IF CONFLICTS BETWEEN THE SPECIFICATIONS AND DRAWINGS OCCUR, THE HIGHER QUALITY OR QUANTITY SHALL BE PROVIDED AND INSTALLED. WHEN CONFLICTS EXIST, CONTRACTOR SHALL PROVIDE A WRITTEN REQUEST FOR CLARIFICATION FROM THE ENGINEER. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL EXPENSES
INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO OBTAIN CLARIFICATION.
3. ALL ELECTRICAL EQUIPMENT ENCLOSURES SHALL BE 16 GAUGE SHEET METAL (MIN). PROVIDED WITH MANUFACTURER'S CORROSION RESISTANT PAINT SYSTEM, PROVIDED WITH CONTINUOUSLY HINGED, LATCHING DOORS (UNO).
4. EQUIPMENT TO BE INSTALLED OUTDOORS SHALL HAVE NEMA 3R ENCLOSURES MIN. EQUIPMENT IN CORROSIVE OR HAZARDOUS ENVIRONMENTS SHALL BE RATED FOR THE
INTENDED USE.
5. CONDUCTORS AND CABLES SHALL BE THHN/THWN SOFT DRAWN, STRANDED COPPER, XHHW FOR UG, USE SOLID COPPER FOR #10 & SMALLER, MIN SIZE #12.
6. FULLY ENCLOSED RACEWAYS AND BOXES REQUIRED FOR ALL WIRING. TYPE REQUIRED IS BY LOCATION.
WIRING DEVICES
1. WIRING DEVICES SHALL BE COMMERCIAL GRADE (MIN), GROUNDING, AND RATED FOR LOAD (20A MIN). NOTE THAT SOME LOCATIONS REQUIRE WEATHER RATED, INDUSTRIAL
OR HEAVY DUTY, AND HOSPITAL GRADE DEVICES.
2. SURFACE MOUNTED RACEWAY FOR RECEPTACLES AND DATA OUTLETS SHALL BE DUAL CHANNEL, METAL RACEWAYS, TWO PIECE DESIGN WITH METAL BASE AND SNAP- ON METAL COVER. ASSEMBLED BASE AND COVER SHALL BE A MINIMUM OF 4" WIDE BY 1.5" DEEP. DEVICE BRACKETS AND COVER PLATES THAT WILL ACCEPT DUPLEX RECEPTACLES AND STANDARD DATA JACK MOUNTING PLATES WITHOUT FIELD CUTTING MUST BE AVAILABLE FROM THE RACEWAY MANUFACTURER.
ENCLOSED SWITCHES AND CONTACTORS
1. DISCONNECTS SHALL BE QUICK MAKE/BREAK LOAD INTERRUPTING KNIFE SWITCHES WITH EXTERNAL HANDLE LOCKABLE IN ON AND OFF POSITIONS, FULLY HINGED DOOR THAT IS LOCKED WHEN ENERGIZED AND PROVIDED WITH A DEFEATER MECHANISM TO OPEN ENCLOSURE WHEN ENERGIZED.
2. ENCLOSED MOTOR STARTERS SHALL HAVE REMOTE START SIGNAL INPUT, FULL SIZED OVERLOADS, CONTROL XFMR WITH PRIMARY & SECONDARY FUSING, HAND-OFF- AUTO SELECTOR SWITCH, (2) NORMALLY OPEN AND (2) NORMALLY CLOSED AUX. DRY CONTACTS. COORDINATE CPT VOLTAGE WITH CONTRACTOR PROVIDING EQUIPMENT
TO BE CONTROLLED.
LIGHTING
1. ALL LIGHT FIXTURES/LAMPS SHALL BE UL LISTED AND CONFORM TO ALL APPLICABLE UL, ANSI AND NFPA STANDARDS.
2. REFER TO LUMINAIRE SCHEDULE FOR FIXTURE, BALLAST, AND LAMP SPECIFICATIONS. SUBSTITUTIONS SHOULD BE APPROVED PRIOR TO BID.
PRODUCT SPECIFICATIONS:
GENERAL REQUIREMENTS
1. PROVIDE RACEWAY AND BOXES AS SPECIFIED BELOW FOR POWER, LIGHTING, COMMUNICATIONS, FIRE ALARM, ACCESS CONTROL/SECURITY, CONTROLS, AND OTHER
SPECIAL SYSTEMS.
2. PROVIDE RACEWAY AND BOXES FOR ALL EQUIPMENT; LIGHTING; WIRING DEVICES; COMMUNICATIONS EQUIPMENT AND OUTLETS; FIRE ALARM EQUIPMENT, APPLIANCES, AND DEVICES; ACCESS CONTROL/SECURITY POINTS; CONTROLS POINTS; AND OTHER SPECIAL SYSTEMS SHOWN ON PLANS.
3. PROVIDE RACEWAY BOXES AT OTHER LOCATIONS AS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, AND COMPLIANCE WITH REGULATORY REQUIREMENTS. RACEWAY AND BOXES ARE SHOWN IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. PROVIDE RACEWAY TO COMPLETE WIRING SYSTEM.
4. PROVIDE COMPRESSION CONNECTIONS FOR ALL METAL RACEWAYS.
IN CONCRETE
1. PROVIDE WRAPPED RIGID STEEL CONDUIT WHERE ENTERING OR EXITING CONCRETE; FOR ELBOWS 1" AND LARGER.
2. PROVIDE RIGID STEEL CONDUIT FOR STRAIGHT RUNS IN CONCRETE.
3. PROVIDE CAST METAL BOXES. NONMETALLIC MAY BE USED ONLY WITH ENGINEER APPROVAL.
4. USE CONCRETE TIGHT, MASONRY RATED BOXES AND FITTINGS WHERE INSTALLED IN CONCRETE, STONE, BRICK, CMU.
CONCEALED DRY INTERIOR LOCATIONS:
1. PROVIDE RIGID STEEL CONDUIT, INTERMEDIATE METAL CONDUIT, OR ELECTRICAL METALLIC TUBING.
2. PROVIDE SHEET-METAL BOXES.
EXPOSED DRY INTERIOR LOCATIONS:
1. PROVIDE RIGID STEEL CONDUIT BELOW 10 FT, AND RIGID STEEL, INTERMEDIATE METAL, OR ELECTRICAL METALLIC TUBING ABOVE 10 FT.
RACEWAY AND BOX SPECIFICATIONS BY LOCATION:
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole Rehabilitation
Center Generator
4800 N.Lamar Blvd. Austin, TX.
78756
24-1053.00
E1.0
EQUIPMENT SCHEDULES
1.
ATS SCHEDULE KEYNOTES:
SB - OPTIONAL STANDBY (NEC ART. 702)
LR - LEGALLY REQUIRED STANDBY (NEC ART. 701)
B. LOAD CLASS: EM - EMERGENCY/LIFE SAFETY (NEC ART. 700)
A. ENGINE EXERCISER: START ENGINE EVERY 7 DAYS; RUN FOR 30 MINUTES BEFORE SHUTTING DOWN. BYPASS EXERCISER CONTROL WHEN NORMAL SOURCE FAILS DURING EXERCISING PERIOD.
ATS SCHEDULE GENERAL...
ATS-SB CUMMINS 1400 3 208 3 4 65 SB 1 Y N O 1 15 60 15 5 30 N 1 N -
EN
G
IN
E
ST
A
R T
D
EL
A Y
(S
TR
A
N
SF
ER
D
EL
A
Y (S
M A
X.
T
O
TA
L
TI
M E
TO
TR
A N
SF
ER
(S
TR
A
N
SF
ER
T
O U
TI
LI
TY
(M
TE
ST
M O
D E
TR
A
N
SF
ER
T
O U
TI
LI
TY
(M
EN
G
IN
E
C O
O
LD
O W
N (M
EQ
U
IP
M
EN
T
M A
R K
B A
SI
S
O F
D
ES
IG
N
M A
N U
FA
C
TU
ER
SI
ZE
(A
PO
LE
S
VO
LT
A G
E
PH W
IR
E
W C
R (k
A
LO
A
D C
LA
SS
EN
C
LO
SU
R E
R A
TI
N
G (N
EM
A
B
YP
A
SS
/IS
O
LA
TI
O N
SE
R
VI
C
E
IN
TR
A
N C
E R
A
TE
D
O
PE
N (O
C
LO
SE
D (C
) T R
A N
SI
TI
O
N TIME SETTINGS FROM LOSS
OF UTILITY
TIME SETTINGS FROM
RESTORATION OF UTILITY
R
EM
O
TE
A N
N U
N C
IA
TO
R
SW
IT
C H
P R
IO
R
IT
Y
LE
VE
L
LO
A
D S
H
ED
K
EY
N O
TE
S
ATS SCHEDULE
1. VERTICAL DISCHARGE
GENERATOR SCHEDULE KEYNOTES:
WPS2 - WEATHER PROTECTIVE / SOUND ATTENUATED LEVEL 2 (75 dBA @ 23') WPS1 - WEATHER PROTECTIVE / SOUND ATTENUATED LEVEL 1 (88 dBA @ 23')
WP - WEATHER PROTECTIVE
G. ENCLOSURE TYPES: N - NONE
P - PROPANE
NG - NATURAL GAS
F. FUEL TYPES: D - DIESEL
E. SUB-BASE, DOUBLE WALL DAY TANK TO COMPLY WITH UL 142 OR UL 2085 FOR TANKS EXCEEDING 660 GALLONS
D. PROVIDE WITH THE FOLLOWING ACCESSORIES -FUEL FILTER, LUBE OIL FILTER, INTAKE AIR FILTER, LUBE OIL COOLER, FUEL TRANSFER PUMP, FUEL PRIMING PUMP, GEAR-DRIVEN WATER PUMP. FURNISH FUEL PRESSURE GAGE, WATER TEMPERATURE GAGE, AND LUBE OIL PRESSURE GAGE ON ENGINE/GENERATOR CONTROL PANEL.
C. GENERATOR SHALL COMPLY WITH ASME B15.1, UL 2200, NFPA 37, AND NFPA 110
B. ALL COMPONENTS, DEVICES, AND ACCESSORIES SHALL BE LISTED AND LABELED AS DEFINED BY NFPA 70.
A. SITE CONDITIONS: ALTITUTE 650', AMBIENT TEMP 110°F
GENERATOR SCHEDULE GENERAL...
GEN-1 CUMMINS 400 NG 208 3 4 Standby WPS2 96 10 2 3 H 125 Y Y Y Y Y N N Y 1400A N 1
C
LA
SS
TY
PE
LE
VE
L
EQ
U
IP
M
EN
T
M A
R K
B A
SI
S
O F
D
ES
IG
N
M A
N U
FA
C
TU
ER
C A
PA
C
IT
Y
(K W
FU
EL
T
YP
E
VO
LT
A G
E
PH W
IR
E
R A
TI
N
G
EN
C
LO
SU
R E
TY
PE
NFPA 110
REQUIREMENTS
EM
IS
SI
O
N S
TI
ER
IN
SU
LA
TI
O N
C
LA
SS
TE
M
PE
R
A
TU
R E
R
IS
E
F)
JA
C
K
ET
H
EA
TE
R
O
IL
/F U
EL
H
EA
TE
R
A N
TI
-C
O N
D
EN
SA
TI
O N
H
EA
TE
R
B A
TT
ER
Y H
EA
TE
R
B A
TT
ER
Y C
H A
R G
ER
R
EM
O
TE
A N
N U
N C
IA
TO
R
SE
PR
A
TE
LY
D
ER
IV
ED
S
YS
TE
M
G R
O U
N D
F A
U
LT
M O
N
IT
O R
IN
G
O U
TP
U
T C
IR
C
U
IT
B R
EA
K
ER
(S
LO
A
D B
A N
K
K
EY
N O
TE
S
GENERATOR SCHEDULE
101660.05
Iron Rod Set
Storage
ETR
MSB
ATS-SB
1 GENERATOR GEN-1 2
4 5
SUNSHINE DRIVE
ETR
UTILITY
XFMR
ETR
METER
7300 FM 2222, Bldg. 2, Ste. 2 Austin, Texas 78730-2314 USA
512.744.4400 main - 512.744.4444 fax www.eeace.com
EEA Project No.
State of registration Firm Registration No.
20250239
F-2497
TX
REVISIONS:
24-1053.00
DECEMBER 4, 2025
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS ARE PROPERTY
OF THE CLIENT LISTED, AND ARE ISSUED IN STRICT
CONFIDENCE AND SHALL NOT BE MADE AVAILABLE,
REPRODUCED, OR COPIED, OR USED FOR ANY OTHER
INTENDED PURPOSE, OR AS BASIS FOR MANUFACTURE OR
SALE OF APARATUS WITHOUT WRITTEN PERMISSION.
CONFIDENTIAL AND PROPRIETARY
SHEET NUMBER:
SHEET NAME:
PROJECT NUMBER:
ISSUE DATE:
SEAL(S) / CONSULTANT:
CLIENT / PROJECT NAME:
Criss Cole Rehabilitation
Center Generator
4800 N.Lamar Blvd. Austin, TX.
78756
24-1053.00
E3.0
ELECTRICAL PLANS
8' 16'4'0 1/8" = 1'-0"E3.0
1 ELECTRICAL PLAN
NEW WORK…