7-26DB26 COPPER HILLS KEYING BID DRAWINGS.pdf
PDF 9 MB Posted
- Attached to
- IFB - Keying Upgrade
- Solicitation number
- 26DB26
- Issued by
- Salt Lake County, Utah
About this file
This file consists of architectural bid drawings for a keying upgrade project at Copper Hills High School in Sandy, Utah, prepared by the Jordan School District. The drawings are floor plans for the first and second floors of the school building, compiled by 3D/I Entelen based on original architect plans. The first floor plan and second floor plan are presented at a scale of 1/32"=1'-0" and include detailed room numbering, locker locations, and fire wall designations indicating both 2-hour and 1-hour fire wall locations throughout the facility. The drawings reference multiple drawing sheets (703-95ORG2O, 703-95ORG1B through 703-95ORG1I, 703-95ORG2J through 703-95ORG2R, and 703-001 and 703-002, all dated 2025.1) that provide the comprehensive keying plan for the bidding process. These drawings serve as the technical specification and bid schedule for bidders to understand the scope of the keying system upgrades required across the school's facility.
The Jordan School District is soliciting bids for this keying upgrade project through an Invitation for Bid (IFB) process in accordance with the Utah Procurement Code. The bid will be awarded to the lowest responsive and responsible bidder, with the selected contractor to receive a Notice to Proceed in the form of a Purchase Order from the JSD Purchasing Department. Bidders must not commence work without formal authorization from the district. The district reserves the right to reject any or all proposals and to waive any informality or technicality in proposals as deemed in the best interest of the Jordan School District.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SANDY, UTAH
JORDAN SCHOOL DISTRICT
DWG COMPILED BY 3D/I ENTELEN
ORIGINAL ARCHITECT:
DWG #:
MHTN
703 COPPER HILLS HIGH
703-95ORG2O
SCALE:
FIRST FLOOR PLAN
1/32"=1'-0"A 0 32' 64'16'8'
A B
.3
L O
C K
E R
S L
O C
K E
R S
38 LOCKERSLOCKERSLOCKERSLOCKERSLOCKERSLOCKERS
INDICATES 2 HOUR FIRE WALL
INDICATES 1 HOUR FIRE WALL
SCALE:
SECOND FLOOR PLAN
1/32"=1'-0"A 0 32' 64'16'8'
M L
K J
H G
F
F G
G .6
J .1
T .3
P .1
J .1
P .1
T .3
A B
F A
B G
DN
F D
D C
1 2 3
L K .3
K J .5
H .7
H G
F E
D C
1 2 3 4
M
1 2 3 4 5 6
INDICATES 2 HOUR FIRE WALL
INDICATES 1 HOUR FIRE WALL
| 703-95ORG1B 2025.1 |
| 703-95ORG1C 2025.1 |
| 703-95ORG1D 2025.1 |
| 703-95ORG1E 2025.1 |
| 703-95ORG1F 2025.1 |
| 703-95ORG1G 2025.1 |
| 703-95ORG1H 2025.1 |
| 703-95ORG1I 2025.1 |
| 703-95ORG2J 2025.1 |
| 703-95ORG2K 2025.1 |
| 703-95ORG2L 2025.1 |
| 703-95ORG2S 2025.1 |
| 703-95ORG2M 2025.1 |
| 703-95ORG2N 2025.1 |
| 703-95ORG2O 2025.1 |
| 703-95ORG2P 2025.1 |
| 703-95ORG2Q 2025.1 |
| 703-95ORG2R 2025.1 |
| 703-001 2025.1 |
| 703-002 2025.1 |
| Copper Hills Keying - Bid Schedule |
File details come from the government source that posted it. Updated .