This is a bid specification document for a keying upgrade project at Copper Hills High School issued by the Jordan School District in Utah. The project involves the installation of mechanical and electromechanical door hardware, specifically focusing on cylindrical locks, exit devices, cylinders, and keying systems for interior and exterior doors throughout the facility. The specification requires the use of Schlage ND Series Grade 1 cylindrical locks compliant with ANSI/BHMA A156.2 Series 4000, Von Duprin 98 Series exit devices, and Schlage Everest 29 T cylinders with a patented restricted keyway system. Hardware finishes are specified as BHMA 626/652 (US26D) for most items, with US32D specified for exterior doors, push plates, and protective elements. The specification mandates a keying conference to finalize the master keying system and establish key control procedures, with final keying schedules to be submitted for approval. Eight hardware sets are defined with varying lock configurations, including standard key-in-lever cylinders, vandal-resistant storeroom locks, and panic hardware units. The specification requires submission of comprehensive documentation including product data, door hardware schedules, key schedules with bitting lists, and as-installed wiring diagrams.

The specification establishes stringent quality assurance requirements, mandating that the hardware supplier be a recognized architectural hardware distributor with minimum five years of experience and employ a DHI-certified Architectural Hardware Consultant or Door Hardware Consultant available for consultation throughout the project. The installer must be a qualified tradesperson skilled in commercial-grade hardware installation. Fire-rated door assemblies must comply with NFPA 80, NFPA 252, and UL testing standards, with hardware listed by UL LLC or acceptable testing organizations. The specification includes manufacturer warranty periods ranging from ten years for Schlage ND Series locks and Von Duprin exit devices to thirty years for LCN 4000 Series closers. All keying must utilize the owner's existing factory-registered system with permanent cylinders and cores marked with blind codes and facility codes, supplemented by 200 key blanks for owner use. The specification requires secure storage and handling of hardware throughout delivery and installation, with coordination required across multiple trades including electrical, security, and doors/frames contractors.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Jordan SD Copper Hills Keying

Project: Jordan SD Copper Hills Keying Allegion: OPT0468653

Print Date: 02/23/2026 1

SECTION 087100 - DOOR HARDWARE

PART 1 - GENERAL

1.01 SUMMARY

A. Section includes:

1. Mechanical door hardware

B. Section excludes:

1. Windows

2. Cabinets (casework), including locks in cabinets

3. Signage

4. Toilet accessories

5. Overhead doors

1.02 REFERENCES

A. UL LLC

1. UL 10B - Fire Test of Door Assemblies

2. UL 10C - Positive Pressure Test of Fire Door Assemblies

3. UL 1784 - Air Leakage Tests of Door Assemblies

4. UL 305 - Panic Hardware

B. DHI - Door and Hardware Institute

1. Sequence and Format for the Hardware Schedule

2. Recommended Locations for Builders Hardware

3. Keying Systems and Nomenclature

4. Installation Guide for Doors and Hardware

C. NFPA – National Fire Protection Association

1. NFPA 70 – National Electric Code

2. NFPA 80 – 2016 Edition – Standard for Fire Doors and Other Opening Protectives

3. NFPA 101 – Life Safety Code

4. NFPA 105 – Smoke and Draft Control Door Assemblies

5. NFPA 252 – Fire Tests of Door Assemblies

D. ANSI - American National Standards Institute

1. ANSI A117.1 – 2017 Edition – Accessible and Usable Buildings and Facilities

2. ANSI/BHMA A156.1 - A156.29, and ANSI/BHMA A156.31 - Standards for Hardware and

Specialties

3. ANSI/BHMA A156.28 - Recommended Practices for Keying Systems

4. ANSI/WDMA I.S. 1A - Interior Architectural Wood Flush Doors

5. ANSI/SDI A250.8 - Standard Steel Doors and Frames

1.03 SUBMITTALS

Print Date: 02/23/2026 2

A. General:

1. Submit in accordance with Conditions of Contract and Division 01 Submittal Procedures.

2. Prior to forwarding submittal:

a. Review drawings and Sections from related trades to verify compatibility with specified hardware.

b. Highlight, encircle, or otherwise specifically identify on submittals: deviations from Contract Documents, issues of incompatibility or other issues which may detrimentally affect the Work.

B. Action Submittals:

1. Product Data: Submit technical product data for each item of door hardware, installation instructions, maintenance of operating parts and finish, and other information necessary to show compliance with requirements.

2. Riser and Wiring Diagrams: After final approval of hardware schedule, submit details of electrified door hardware, indicating:

a. Wiring Diagrams: For power, signal, and control wiring and including:

1) Details of interface of electrified door hardware and building safety and security systems.

2) Schematic diagram of systems that interface with electrified door hardware.

3) Point-to-point wiring.

4) Risers.

3. Samples for Verification: If requested by Architect, submit production sample of requested door hardware unit in finish indicated and tagged with full description for coordination with schedule.

a. Samples will be returned to supplier. Units that are acceptable to Architect may, after final check of operations, be incorporated into Work, within limitations of key coordination requirements.

4. Door Hardware Schedule:

a. Submit concurrent with submissions of Product Data, Samples, and Shop Drawings.

Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate fabrication of other work critical in Project construction schedule.

b. Submit under direct supervision of a Door Hardware Institute (DHI) certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) with hardware sets in vertical format as illustrated by Sequence of Format for the Hardware Schedule published by DHI.

c. Indicate complete designations of each item required for each opening, include:

1) Door Index: door number, heading number, and Architect's hardware set number.

2) Quantity, type, style, function, size, and finish of each hardware item.

3) Name and manufacturer of each item.

4) Fastenings and other pertinent information.

5) Location of each hardware set cross-referenced to indications on Drawings.

6) Explanation of all abbreviations, symbols, and codes contained in schedule.

7) Mounting locations for hardware.

8) Door and frame sizes and materials.

9) Degree of door swing and handing.

10) Operational Description of openings with electrified hardware covering egress, ingress (access), and fire/smoke alarm connections.

5. Key Schedule:

Print Date: 02/23/2026 3

a. After Keying Conference, provide keying schedule that includes levels of keying, explanations of key system's function, key symbols used, and door numbers controlled.

b. Use ANSI/BHMA A156.28 ''Recommended Practices for Keying Systems'' as guideline for nomenclature, definitions, and approach for selecting optimal keying system.

c. Provide 3 copies of keying schedule for review prepared and detailed in accordance with referenced DHI publication. Include schematic keying diagram and index each key to unique door designations.

d. Index keying schedule by door number, keyset, hardware heading number, cross keying instructions, and special key stamping instructions.

e. Provide one complete bitting list of key cuts and one key system schematic illustrating system usage and expansion. Forward bitting list, key cuts and key system schematic directly to Owner, by means as directed by Owner.

f. Prepare key schedule by or under supervision of supplier, detailing Owner's final keying instructions for locks.

C. Informational Submittals:

1. Provide Qualification Data for Supplier, Installer and Architectural Hardware Consultant.

2. Provide Product Data:

a. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.

b. Include warranties for specified door hardware.

D. Closeout Submittals:

1. Operations and Maintenance Data: Provide in accordance with Division 01 and include:

a. Complete information on care, maintenance, and adjustment; data on repair and replacement parts, and information on preservation of finishes.

b. Catalog pages for each product.

c. Final approved hardware schedule edited to reflect conditions as installed.

d. Final keying schedule

e. Copy of warranties including appropriate reference numbers for manufacturers to identify project.

f. As-installed wiring diagrams for each opening connected to power, both low voltage and 110 volts.

1.04 QUALITY ASSURANCE

A. Qualifications and Responsibilities:

1. Supplier: Recognized architectural hardware supplier with a minimum of 5 years documented experience supplying both mechanical and electromechanical door hardware similar in quantity, type, and quality to that indicated for this Project. Supplier to be recognized as a factory direct distributor by the manufacturer of the primary materials with a warehousing facility in the Project’s vicinity. Supplier to have on staff, a certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) available to Owner, Architect, and Contractor, at reasonable times during the Work for consultation.

2. Installer: Qualified tradesperson skilled in the application of commercial grade hardware with experience installing door hardware similar in quantity, type, and quality as indicated for this Project.

3. Architectural Hardware Consultant: Person who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project and meets these requirements:

Print Date: 02/23/2026 4

a. For door hardware: DHI certified AHC or DHC.

b. Can provide installation and technical data to Architect and other related subcontractors.

c. Can inspect and verify components are in working order upon completion of installation.

d. Capable of producing wiring diagram and coordinating installation of electrified hardware with Architect and electrical engineers.

4. Single Source Responsibility: Obtain each type of door hardware from single manufacturer.

B. Certifications:

1. Fire-Rated Door Openings:

a. Provide door hardware for fire-rated openings that complies with NFPA 80 and requirements of authorities having jurisdiction.

b. Provide only items of door hardware that are listed products tested by UL LLC, Intertek Testing Services, or other testing and inspecting organizations acceptable to authorities having jurisdiction for use on types and sizes of doors indicated, based on testing at positive pressure and according to NFPA 252 or UL 10C and in compliance with requirements of fire-rated door and door frame labels.

2. Smoke and Draft Control Door Assemblies:

a. Provide door hardware that meets requirements of assemblies tested according to

UL 1784 and installed in compliance with NFPA 105

b. Comply with the maximum air leakage of 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) at tested pressure differential of 0.3-inch wg (75 Pa) of water.

3. Electrified Door Hardware

a. Listed and labeled as defined in NFPA 70, Article 100, by testing agency acceptable to authorities having jurisdiction.

4. Accessibility Requirements:

a. Comply with governing accessibility regulations cited in ''REFERENCES'' article

087100, 1.02.D3 herein for door hardware on doors in an accessible route. This project must comply with all Federal Americans with Disability Act regulations and all Local Accessibility Regulations.

C. Pre-Installation Meetings

1. Keying Conference

a. Incorporate keying conference decisions into final keying schedule after reviewing door hardware keying system including:

1) Function of building, flow of traffic, purpose of each area, degree of security required, and plans for future expansion.

2) Preliminary key system schematic diagram.

3) Requirements for key control system.

4) Requirements for access control.

5) Address for delivery of keys.

2. Pre-installation Conference

a. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.

b. Inspect and discuss preparatory work performed by other trades.

c. Inspect and discuss electrical roughing-in for electrified door hardware.

d. Review sequence of operation for each type of electrified door hardware.

Print Date: 02/23/2026 5

e. Review required testing, inspecting, and certifying procedures.

f. Review questions or concerns related to proper installation and adjustment of door hardware.

3. Electrified Hardware Coordination Conference:

a. Prior to ordering electrified hardware, schedule and hold meeting to coordinate door hardware with security, electrical, doors and frames, and other related suppliers.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Inventory door hardware on receipt and provide secure lock-up for hardware delivered to Project site. Promptly replace products damaged during shipping

B. Tag each item or package separately with identification coordinated with final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package. Deliver each article of hardware in manufacturer's original packaging.

C. Maintain manufacturer-recommended environmental conditions throughout storage and installation periods.

D. Provide secure lock-up for door hardware delivered to Project. Control handling and installation of hardware items so that completion of Work will not be delayed by hardware losses both before and after installation.

E. Handle hardware in manner to avoid damage, marring, or scratching. Correct, replace or repair products damaged during Work. Protect products against malfunction due to paint, solvent, cleanser, or any chemical agent.

F. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.

1.06 COORDINATION

A. Coordinate layout and installation of floor-recessed door hardware with floor construction.

Cast anchoring inserts into concrete.

B. Installation Templates: Distribute for doors, frames, and other work specified to be factory or shop prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

C. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant.

D. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.

1.07 WARRANTY

A. Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within published warranty period.

1. Warranty does not cover damage or faulty operation due to improper installation, improper use or abuse.

Print Date: 02/23/2026 6

2. Warranty Period: Beginning from date of Substantial Completion, for durations indicated in manufacturer's published listings.

a. Mechanical Warranty

1) Locks

a) Schlage ND Series: 10 years

2) Exit Devices

a) Von Duprin: 10 years

3) Closers

a) LCN 4000 Series: 30 years

1.08 MAINTENANCE

A. Furnish complete set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.

B. Turn over unused materials to Owner for maintenance purposes.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. The Owner requires use of certain products for their unique characteristics and project suitability to ensure continuity of existing and future performance and maintenance standards. After investigating available product offerings, the Awarding Authority has elected to prepare proprietary specifications. These products are specified with the notation: ''No Substitute.''

1. Where ''No Substitute'' is noted, submittals and substitution requests for other products will not be considered.

B. Approval of alternate manufacturers and/or products other than those listed as ''Scheduled Manufacturer'' or ''Acceptable Manufacturers'' in the individual article for the product category are only to be considered by official substitution request in accordance with section 01 25 00.

C. Approval of products from manufacturers indicated in ''Acceptable Manufacturers'' is contingent upon those products providing all functions and features and meeting all requirements of scheduled manufacturer's product.

D. Where specified hardware is not adaptable to finished shape or size of members requiring hardware, furnish suitable types having same operation and quality as type specified, subject to Architect's approval.

2.02 MATERIALS

A. Fabrication

1. Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. provide screws according to manufacturer’s recognized installation standards for application intended.

Print Date: 02/23/2026 7

2. Finish exposed screws to match hardware finish, or, if exposed in surfaces of other work, to match finish of this other work including prepared for paint surfaces to receive painted finish.

3. Provide concealed fasteners wherever possible for hardware units exposed when door is closed. Coordinate with “Metal Doors and Frames”, “Flush Wood Doors”, “Stile and Rail Wood Doors” to ensure proper reinforcements. Advise the Architect where visible fasteners, such as thru bolts, are required.

B. Provide screws, bolts, expansion shields, drop plates and other devices necessary for hardware installation.

1. Where fasteners are exposed to view: Finish to match adjacent door hardware material.

C. Cable and Connectors:

1. Where scheduled in the hardware sets, provide each item of electrified hardware and wire harnesses with number and gage of wires enough to accommodate electric function of specified hardware.

2. Provide Molex connectors that plug directly into connectors from harnesses, electric locking and power transfer devices.

3. Provide through-door wire harness for each electrified locking device installed in a door and wire harness for each electrified hinge, electrified continuous hinge, electrified pivot, and electric power transfer for connection to power supplies.

2.03 CYLINDRICAL LOCKS – GRADE 1

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage ND series

B. Requirements:

1. Provide cylindrical locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 1, and UL Listed for 3-hour fire doors.

2. Indicators: Where specified, provide escutcheon with lock status indicator window on top of lockset rose:

a. Escutcheon height (including rose) 6.05 inches high by 3.68 inches wide.

b. Indicator window measuring a minimum 3.52-inch by .60 inch with 1.92 square-inches of front facing viewing area and 180-degree visibility with a total of .236 square-inches of total viewable area.

c. Provide snap-in serviceable window to prevent tampering. Lock must function if indicator is compromised.

d. Provide messages color-coded with full text and symbol, as scheduled, for easy visibility.

e. Unlocked and Unoccupied message will display on white background, and Locked and Occupied message will display on red background.

3. Cylinders: Refer to ''KEYING'' article, herein.

4. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with

1/2-inch latch throw. Provide proper latch throw for UL listing at pairs.

5. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws.

6. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.

7. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.

Print Date: 02/23/2026 8

8. Provide electrified options as scheduled in the hardware sets.

9. Lever Trim: Solid cast levers without plastic inserts and wrought roses on both sides.

a. Vandlgard: Provide levers with vandal resistant technology for use at heavy traffic or abusive applications.

b. Lever Design: RHO

2.04 CYLINDERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage Everest 29 T

B. Requirements:

1. Provide cylinders/cores compliant with ANSI/BHMA A156.5; latest revision; cylinder face finished to match lockset; manufacturer’s series as indicated. Refer to “KEYING” article, herein.

2. Provide cylinders in the below-listed configuration(s), distributed throughout the Project as indicated.

a. Patented Restricted: cylinder with permanent core with patented, restricted keyway.

b. Patented Restricted: cylinder with interchangeable core with patented, restricted keyway.

3. Patent Protection: Cylinders/cores requiring use of restricted, patented keys, patent protected.

4. Nickel silver bottom pins.

2.05 KEYING

A. Scheduled System:

1. Existing factory registered system:

a. Provide cylinders/cores keyed into Owner’s existing factory registered keying system.

Comply with guidelines in ANSI/BHMA A156.28, incorporating decisions made at keying conference.

B. Requirements:

1. Permanent Keying:

a. Provide permanent cylinders/cores keyed by the manufacturer according to the following key system.

1) Master Keying system as directed by the Owner.

b. Forward bitting list and keys separately from cylinders, by means as directed by Owner. Failure to comply with forwarding requirements will be cause for replacement of cylinders/cores involved at no additional cost to Owner.

c. Provide keys with the following features:

1) Material: Nickel silver; minimum thickness of .107-inch (2.3mm)

2) Patent Protection: Keys and blanks protected by one or more utility patent(s).

d. Identification:

1) Mark permanent cylinders/cores and keys with applicable blind code for identification. Do not provide blind code marks with actual key cuts.

2) Identification stamping provisions must be approved by the Architect and Owner.

Print Date: 02/23/2026 9

3) Stamp cylinders/cores and keys with Owner’s unique key system facility code as established by the manufacturer; key symbol and embossed or stamped with “DO NOT DUPLICATE” along with the “PATENTED” or patent number to enforce the patent protection.

4) Failure to comply with stamping requirements will be cause for replacement of keys involved at no additional cost to Owner.

5) Forward permanent cylinders/cores to Owner, separately from keys, by means as directed by Owner.

e. Quantity: Furnish in the following quantities.

1) Permanent Control Keys: 3.

2) Master Keys: 6.

3) Change (Day) Keys: 3 per cylinder/core that is keyed differently

4) Key Blanks: Provide 200 key blanks for owner’s use

2.06 FINISHES

A. FINISH: BHMA 626/652 (US26D); EXCEPT:

1. Hinges at Exterior Doors: BHMA 630 (US32D)

2. Aluminum Geared Continuous Hinges: BHMA 628 (US28)

3. Push Plates, Pulls, and Push Bars: BHMA 630 (US32D)

4. Protection Plates: BHMA 630 (US32D)

5. Overhead Stops and Holders: BHMA 630 (US32D)

6. Door Closers: Powder Coat to Match

7. Wall Stops: BHMA 630 (US32D)

8. Latch Protectors: BHMA 630 (US32D)

9. Weatherstripping: Clear Anodized Aluminum

10. Thresholds: Mill Finish Aluminum

2.07 EXIT DEVICES

A. Acceptable Products:

1. Von Duprin: 98 Series

B. Requirements:

1. ANSI Grade: BHMA/ANSI A156.3, Grade 1.

2. Device Construction:

a. Exit device(s) shall have a mechanism case constructed of extruded aluminum or wrought stainless steel, base plates constructed of cold rolled or cast steel, push pad of extruded aluminum with stainless steel covering or wrought stainless steel, and end caps with flush mounted, sloped design. At full-glass doors, provide exit devices with no exposed fasteners or rivets visible through glass.

Where required by stile width, provide narrow-stile type device.

b. Latchbolt: Provide Pullman-type deadlocking latch bolts constructed of stainless steel. Where specified provide high security Pullman-type latchbolt that collapses to be square faced under high pull forces. Latch return springs shall be compression type. Tension and Torsion latch return springs are not acceptable.

c. Dogging Mechanism: where dogging or latch-retraction options are not specifically scheduled for non-fire rated doors, provide device with a hex-key

Print Date: 02/23/2026 10 activated hook-type dogging mechanism constructed of steel. Dogging option not to be provided in classroom or instructional spaces.

d. Plastic or nylon used for the push pad, or parts in the dogging mechanism or latchbolt mechanism are unacceptable.

e. Sound Dampening: Device shall be provided with factory-installed sound dampening materials.

f. Provide device type, function, and trim style as indicated in hardware schedules.

3. Where exit device(s) are provided for fire rated door, provide with fire listing and label indicating “Fire Exit Hardware”. If device is mounted on wood doors, provide sex nuts and bolts.

4. Provide shim kits, filler plates, and other accessories as required for each opening.

5. Unless otherwise indicated in the sets, provide device with roller-type strike.

6. Where scheduled, provide removable mullions by same manufacturer as provided exit devices. Provide mullion stabilizers, key removable option, strike preps, and fire rating as indicated in sets.

7. Concealed vertical exit devices shall be a cable-actuated concealed vertical latch system available in two-point and less bottom latch (LBL) configurations. Vertical rods are not acceptable.

a. Cable shall include color-coded stainless steel with polytetrafluoroethylene

(Teflon®) liner and stainless steel core wire. Latches and center slides are color coded to aid in installation. Conduit and core wire ends snap into latch and center slides without the use of tools. Latchbolts and blocking cams shall be manufactured from sintered metal low carbon copper- infiltrated steel, with a molybdenum disulfide coating for low friction and consistent performance.

b. Top latchbolt shall have a minimum 0.382 inch and greater than 90 degree engagement with strike to prevent door and frame separation under high static load. Bottom latchbolt, when used, shall have a minimum of 0.44 inch engagement with strike.

c. Product cycle life shall exceed 1,000,000 cycles.

d. Latch release does not require separate trigger mechanism.

e. Top and bottom latch must operate independently of each other. Top latch will fully engage top strike even when bottom latch is compromised. f. Cable and latching system shall have the ability to:

1) Be assembled as a complete assembly and function prior to being installed in the door.

2) Install into the door as a one-piece single assembly

3) Be installed independently of device installation and function on door even prior to device and trim installation.

4) Connect to the exit device at a single attachment point.

5) Adjust bottom latch height from a single point, after the system is installed and connected to exit device, while the door is hanging

Print Date: 02/23/2026 11

6) Alter latch position up and down within two-inches without additional adjustment.

7) Ability to remove the system while door is hanging.

8) Configure latchbolt mounting: double or single tab mount for steel doors, and wood doors, face mount for aluminum doors, eliminating requirement of tabs.

9) Provide adjustable exit device to latch center line adjustment. Ensures double tab mounting option for top latch, regardless of exit device centerline.

PART 3 - EXECUTION

3.01 EXAMINATION

A. Prior to installation of hardware, examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance. Verify doors, frames, and walls have been properly reinforced for hardware installation.

B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.

C. Submit a list of deficiencies in writing and proceed with installation only after unsatisfactory conditions have been corrected.

3.02 INSTALLATION

A. Mount door hardware units at heights to comply with the following, unless otherwise indicated or required to comply with governing regulations.

1. Standard Steel Doors and Frames: ANSI/SDI A250.8.

2. Custom Steel Doors and Frames: HMMA 831.

3. Interior Architectural Wood Flush Doors: ANSI/WDMA I.S. 1A

4. Installation Guide for Doors and Hardware: DHI TDH-007-20

B. Install door hardware in accordance with NFPA 80, NFPA 101 and provide post-install inspection, testing as specified in section 1.03.E unless otherwise required to comply with governing regulations.

C. Install each hardware item in compliance with manufacturer's instructions and recommendations, using only fasteners provided by manufacturer.

D. Do not install surface mounted items until finishes have been completed on substrate. Protect all installed hardware during painting.

E. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate as necessary for proper installation and operation.

F. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.

G. Install operating parts so they move freely and smoothly without binding, sticking, or excessive clearance.

Print Date: 02/23/2026 12

H. Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than quantity recommended by manufacturer for application indicated.

I. Lock Cylinders:

1. Install construction cores to secure building and areas during construction period.

2. Replace construction cores with permanent cores as indicated in keying section.

3. Furnish permanent cores to Owner for installation.

J. Wiring: Coordinate with Division 26, ELECTRICAL and Division 28 ELECTRONIC SAFETY AND SECURITY sections for:

1. Conduit, junction boxes and wire pulls.

2. Connections to and from power supplies to electrified hardware.

3. Connections to fire/smoke alarm system and smoke evacuation system.

4. Connection of wire to door position switches and wire runs to central room or area, as directed by Architect.

5. Connections to panel interface modules, controllers, and gateways.

6. Testing and labeling wires with Architect's opening number.

K. Key Control System: Tag keys and place them on markers and hooks in key control system cabinet, as determined by final keying schedule.

L. Continuous Hinges: Re-locate the door and frame fire rating labels where they will remain visible so that the hinge does not cover the label once installed.

M. Door Closers & Auto Operators: Mount closers/operators on room side of corridor doors, inside of exterior doors, and stair side of stairway doors from corridors. Mount closers/operators so they are not visible in corridors, lobbies and other public spaces unless approved by Architect.

N. Overhead Stops/Holders: Mount overhead stops/holders on room side of corridor doors, inside of exterior doors, and stair side of stairway doors.

O. Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings or in equipment room, or alternate location as directed by Architect.

P. Thresholds:

1. Set thresholds in full bed of sealant complying with requirements specified in Division 07 Section ''Joint Sealants.''

2. Aluminum thresholds to be cut-in, and scribed around mullions, frame members, and stops. Do not butt to thresholds. Provide a continuous surface across full width of opening from jamb to jamb.

3. Where aluminum panic-type (rabbeted) thresholds with neoprene inserts are specified, undercut doors as required to properly mate with seal in threshold.

Q. Stops: Provide floor stops for doors unless wall or other type stops are indicated in door hardware schedule. Do not mount floor stops where they may impede traffic or present tripping hazard.

R. Perimeter Gasketing:

1. Apply to head and jamb, forming seal between door and frame.

Print Date: 02/23/2026 13

2. Install gasketing in a manner eliminating need to cut any seal to install surface mounted hardware. Install compatible mounting bracket for surface mounted hardware unless minimum 1/4 inch thick solid aluminum seals are provided for mounting of surface applied hardware.

S. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.

T. Door Bottoms and Sweeps: Apply to bottom of door, forming seal with threshold when door is closed.

3.03 ADJUSTING

A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

1. Spring Hinges: Adjust to achieve positive latching when door can close freely from an open position of 30 degrees.

2. Electric Strikes: Adjust horizontal and vertical alignment of keeper to properly engage lock bolt.

3. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction.

B. Occupancy Adjustment: Approximately three to six months after date of Substantial Completion, examine and readjust each item of door hardware, including adjusting operating forces, as necessary to ensure function of doors and door hardware.

3.04 CLEANING AND PROTECTION

A. Clean adjacent surfaces soiled by door hardware installation.

B. Clean operating items per manufacturer's instructions to restore proper function and finish.

C. Provide final protection and maintain conditions that ensure door hardware is without damage or deterioration at time of Substantial Completion.

3.05 KEY CONTROL CABINET

A. Acceptable Products:

1. Lund, Inc. 1200 Series

B. Requirements:

1. Provide a key control system including envelopes, labels, and tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet.

2. Provide complete cross-index system set up by Owner, and place keys on markers and hooks in the cabinet as determined by the final key schedule.

3. Provide hinged-panel type cabinet for wall mounting with capacity for 250 unique keys.

Print Date: 02/23/2026 14

3.06 DOOR HARDWARE SCHEDULE

A. The intent of the hardware specification is to specify the hardware for interior and exterior doors, and to establish a type, continuity, and standard of quality. However, it is the door hardware supplier's responsibility to thoroughly review existing conditions, schedules, specifications, drawings, and other Contract Documents to verify the suitability of the hardware specified.

B. Discrepancies, conflicting hardware, and missing items are to be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application.

C. Hardware items are referenced in the following hardware schedule. Refer to the above specifications for special features, options, cylinders/keying, and other requirements.

D. Hardware Sets:

Abbreviation Name

SCH Schlage Lock Company

HW SET: 1

For use on Door #(s): See Schedule

Each to have:

1 EA K-I-L CYLINDER 24-147 EV29 T 626 SCH

KEY IN LEVER CYLINDER (NON-IC) THIS IS FOR YALE 5400

HW SET: 2

Each to have:

1 EA FSIC CYLINDER 23-030 EV29 T 626 SCH

HW SET: 3

Each to have:

1 EA VANDL STOREROOM

LOCK

ND96RD RHO 626 SCH

COMPLETE STOREROOM FUNCTION WITH VANDAL GUARD INCLUDING PERMANENT KEYED

FSIC CORE (EV29 T)

Print Date: 02/23/2026 15

HW SET: 4

For use on Door #(s): See Schedule

Each to have:

1 EA MORTISE CYLINDER 30-030 X K510-680 EV29 T 36-

626 SCH

THIS IS FSIC COMPLETE MORTISE CYLINDER AND CORE WITH STRAIGHT CAM WORKS FOR

CORBIN EXIT TRIM, MULLIONS (MAY NEED ADDITIONAL BLOCKING RINGS)

HW SET: 5

Each to have:

1 EA PANIC ARDWARE LD-98-L-06 626 VON

HW SET: 6

Each to have:

2 EA PANIC ARDWARE LD-98-L-06 626 VON

HW SET: 7

Each to have:

3 EA PANIC ARDWARE LD-98-L-06 626 VON

HW SET: 8

Each to have:

4 EA PANIC ARDWARE LD-98-L-06 626 VON

END OF SECTION