This document consists of approved plans for a roof replacement project at Snow College's Trades and Industries building, prepared by the Utah Division of Facilities Construction and Management (DFCM). The project, identified as #27006700, involves the complete replacement of the existing roof system on this facility. The approved plans serve as the technical specifications and design documentation that prequalified roofing contractors must follow when submitting bids for the Stage II Invitation to Bid. Only contractors who have successfully completed Stage I prequalification and appear on the current DFCM Prequalified Contractors list are eligible to submit bids for this project.
The project has a construction cost estimate of $700,000.00 and requires sealed bids from qualified roofing contractors. The approved plans establish the scope of work, material specifications, construction standards, and technical requirements that bidders must reference when preparing their proposals. As prequalified bidders have already been vetted during the Stage I process, the Stage II bidding process focuses on competitive pricing and contractor selection based on qualifications and bid amounts. The approved plans ensure that all bidding contractors work from identical specifications and design standards, promoting fair competition and consistent project delivery.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GI001
TITLE SHEET
GENERAL NOTES
AND SHEET INDEX
SNOW COLLEGE
TRADES BUILDING
ROOF REPLACEMENT
325 WEST 100 NORTH
EPHRAIM, UTAH
GENERAL ABBREVIATIONS DRAWING INDEXMATERIALS LEGEND GRAPHIC SYMBOLSCODE ANALYSIS
PROJECT DIRECTORY
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
North: __________ South: __________ East: __________ West: __________
Special Use and Occupancy (e.g. High Rise, Covered Mall): _____________________
d) Unlimited Area Building: Yes ________ No ________ Code Section: ________ a a
3) Three Story: A (3) _______________________________________________
2) Two Story: A (2) ________________________________________________
1) One Story: _____________________________________________________
c) Total Allowable Area for:
1_< Allowable Area
Actual Area
b) Sum of the Ratio Calculations for Mixed Occupancies:
a) 0.25I =f F P 30
W stA IfIA ttaA = A + +
Official for Complex Buildings. Including, but not limited to:
a) High Rise Requirements.
b) Atriums.
c) Performance Based Criteria.
d) Means or Egress Analysis.
2) Additional Code Information shall be provided at the discretion of the Building Code Accessibility Chapters, the more restrictive requirement shall govern.
through - ADA Guidelines and specific reference to the International Building
1) In case of conflict with the U.S. Department of Justice Federal Registers Parts
FOOTNOTES:
d) Drinking Fountains: ______ Service Sinks: ______
c) Bath Tubs or Showers: ______
b) Lavatories - Required (m) ______ (f) ______ Provided (m) ______ (f) ______
a) Water Closets - Required (m) ______ (f) ______ Provided (m) ______ (f) _____
M. Minimum Number of Required Plumbing Facilities:
Exit Width Required: ______ Exit Width Provided: ______
Element Hours Assembly ListingListing
Element AssemblyHours
Smoke Partitions Fire Partitions
Exterior Bearing Walls Interior Bearing Walls Exterior Non-Bearing Walls Structural Frame Partitions - Permanent Fire Barriers
Floors - Ceiling Floors Roofs - Ceiling Roofs Exterior Doors and Windows Shaft Enclosures Fire Walls
BAHTBABABA
Design Wind Speed: _____________ mphB. Seismic Design Category: ___________
L. Design Occupant Load: ______
K. Fire Resistance Rating Requirements for Building Elements (hours).
Area Modifications:J.
__________________________________________________________Tabular Area:I.
per Floor (square feet): ________________________________________Actual AreaH.
Number of Stories: ___________________ Building Height: ___________________G.
Required: ________ Provided: ________ Type of Sprinkler System: ________ Sprinklers:F.
Mixed Occupancies: _______________ Nonseparated Uses: _______________E.
separation distance (in hours):
Requirements for the Exterior Walls based on the fireFire Resistance RatingD.
C. Type of Construction (circle one):
Change in Use: Yes ______ No ______ Mixed Occupancy: Yes ______ No ______
National Electrical Code
Conservation Code International Energy International Fire Code International Plumbing Code International Mechanical Code International Building Code
YearYear
APPLICABLE CODES
A. Occupancy and Group: ________ ________ ________ ________ ________
g) Fire Stopping, Including Tested Design Number.
f) Exterior and Interior Accessibility Route.
e) Fire Assembly Locator Sheet.
ICC/ANSI A117.1-2003
GENERAL NOTES
COMPLIANCE REQUIREMENTS
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
REVIEWED FOR CODE
COMPLIANCE
GI002
SPECIAL INSPECTIONS
AND TESTING
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
2 2
5 5
7 7 7 7 7 7
AS101
PUBLIC SAFETY
SITE PLAN
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
SITE KEYED NOTES
GENERAL SITE NOTES
N
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
3 3
4 4 4444
5 5
8 8
10 11
1414 14 14
18 18
AE101
ROOF PLAN
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
GENERAL ROOFING NOTESROOF KEYED NOTES
Award of Substantial Completion
N
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
AE501
DETAILS
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
PRIMARY ROOF DRAIN W/
NOTCHED RETAINING RING
AND CAST IRON DOME
LINE OF SUMP (BEYOND)
ROOF DECK VARIES BY
PROJECT
SECONDARY ROOF DRAIN
WITH NON-NOTCHED
RETAINING RING AND CAST
IRON DOME - SET 2" HIGHER
THAN PRIMARY DRAIN
SLOPE IN SUMP
BETWEEN DRAINS
RIGID INSULATION -
VARIES BY PROJECT
MANUFACTURERS
TAPERED INSULATION
SYSTEM
ROOFING MEMBRANE -
VARIES BY PROJECT
6'-0"MIN. 10' - 0" MAX. (BASED ON SPACING BETWEEN DRAIN BOWLS AS INDICATED BELOW)
2"
SLOPE IN SUMP
BETWEEN DRAINS
3' -0
(8
P
IP
E D
IA
M
ET
ER
S M
IN
.O
R
PI
PE
D
IA
M
ET
ER
S M
AX
6' - 0" MIN. 10' - 0" MAX. (BASED ON SPACING BETWEEN DRAIN BOWLS AS INDICATED BELOW)
SECTION
PLAN
EDGE OF SUMP
PRIMARY ROOF DRAIN W/
NOTCHED RETAINING RING
AND CAST IRON DOME
SECONDARY ROOF DRAIN
WITH NON-NOTCHED
RETAINING RING AND CAST
IRON DOME - SET 2" HIGHER
THAN PRIMARY DRAIN
PRESERVATIVE TREATED
NAILERS / SHIMS AS REQ'DNOTE: WHERE RAISING OF
SECONDARY DRAIN IS REQUIRED TO
ACHIEVE THIS DETAIL, MODIFY
EXISTING PLUMBING AS REQUIRED
2' - 0" (HOLD) 2' - 0" MIN. 6' - 0" MAX
BETWEEN DRAIN BOWLS
2' - 0" (HOLD)
d2 ROOF DRAIN AND OVERFLOW ROOF DRAIN DETAIL
SCALE: 1-1/2" = 1'-0"
FLASHING MEMBRANE AND
SEALANT
STAINLESS STEEL
CLAMPING RING
PLUMBING VENT / STACK
ADHERED FIELD FLASHED
MEMBRANE
TYPICAL
HEAT WELDED
FLASHING
NOTE:
IF THE TOP OF THE EXISTING VENT IS
LESS THAN 12" ABOVE THE NEW
FINISHED ROOF SURFACE, THE VENT
MUST BE EXTENDED
" M
IN
2"
MIN.
2"
MIN.
VARIES
TYPICAL
STAINLESS STEEL CLAMPING
RING
SPM MEMBRANE PRE-FABRICATED
BOOT WITH MINIMUM 1" TURN-UP
CONTINUOUS WELD
HEAT WELDED FLASHING
FLASHING MEMBRANE AND
SEALANT
PIPE / CONDUIT
2"
MIN.
2"
MIN.ROOFING MEMBRANE - VARIES
BY PROJECT
ROOF DECK VARIES BY
PROJECT
RIGID INSULATION -
VARIES BY PROJECT
ROOFING MEMBRANE - VARIES
BY PROJECT
ROOF DECK VARIES BY
PROJECT
RIGID INSULATION -
VARIES BY PROJECT
NOTE THAT WHERE A PIPE IS CAPABLE OF BEING
FLASHED USING A ROOFING MANUFACTURES
PRE-FABRICATED BOOT (SUCH AS SHOWN
ABOVE), THAT OPTION IS REQUIRED AND
SHOULD BE USED OVER A FIELD FLASHED
DETAIL (SUCH AS SHOWN BELOW)
6 2
6 2
6 2
8" M
IN
R O
O F
SU
R
FA
C
E
TO
F
AS
TE
N
ER
S)
18" MIN.
(CURB TO PENETRATION TYP.)
N
AI
LE
R
S
SH
IM
S
TO
M
AT
C H
IN
SU
LA
TI
O N
D
EP
TH
" M
IN
TO
T
O P
O F
C U
R B
1/4
1/4
BOTH
ENDS
1/4
8" M
IN
1.
2.
3.
4.
5.
6.
GENERAL NOTES:
IF CURB CONSTRUCTION IS EXISTING, THE CONTRACTOR IS RESPONSIBLE FOR MODIFYING / RAISING THE CURB AS REQUIRED TO ACHIEVE THE MIN. DIMENSIONS INDICATED (FROM THE FINISHED ROOF SURFACE TO TOP OF CURB) - IN SUCH CASES, LICENSED MECHANICAL & ELECTRICAL CONTRACTORS MUST PERFORM ALL REQUIRED CHANGES TO MECHANICAL EQUIPMENT / LINE SETS / ELECTRICAL WIRING & CONNECTIONS ETC.
ALL EXISTING ELECTRICAL LINES / CONNECTIONS (AS OCCUR) ARE TO BE REPLACED WITH NEW WITH THE EXCEPTION OF RIGHT AT THE EQUIPMENT LOCATION - ELECTRICAL LINES AND JUNCTION BOX'S THAT ARE RUN ABOVE THE ROOF, AND OR DECK, ARE TO BE REPLACED AND RE-RUN BENEATH THE DECK, BACK TO THE NEAREST JUNCTION OR ELECTRICAL BOX - NO FLEXIBLE ELECTRICAL CONDUIT WILL BE ALLOWED LOWER THAN 12" ABOVE THE FINISHED ROOF SURFACE - ALL ELECTRICAL WORK MUST BE DONE TO NEC
STANDARDS
WALK PADS ARE TO BE PROVIDED AT ALL 4 SIDES OF CURBS
CURBS AND SUPPORT STANDS MUST BE CONSTRUCTED SO TOP IS LEVEL
NO WELDING WILL BE ALLOWED ON THE ROOF - WELDING SHALL BE DONE IN THE PARKING LOT OR IN A
SHOP
IF FINAL INSULATION DEPTH IS GREATER THAN THE EXISTING INSULATION DEPTH, PROVIDE ADDITIONAL NAILERS / SHIMS AS REQ'D. TO ACHIEVE THE MINIMUM HEIGHT INDICATED FROM THE FINAL ROOFING
SURFACE TO THE TOP OF THE CURB
TYP. CANTILEVER SUPPORT STAND
7.
8.
9.
10.
GENERAL NOTES (CONT.):
VOIDS INSIDE THE CURB, AROUND DUCTING, ARE TO BE FILLED WITH RIGID OR BATT INSULATION AS REQ'D.
TO MATCH THE R-VALUE OF THE REST OF THE ROOF
SUPPORT STANDS ARE TO BE USED TO SUPPORT ALL CANTILEVERED EQUIPMENT - NO FEET OR SLEEPERS
RESTING ON ROOF WILL BE ALLOWED
NOTE THAT A MINIMUM OF (2) SUPPORT LEGS ARE TO BE PROVIDED FOR EACH PIECE OF EQUIPMENT THAT HAS CANTILEVERED ELEMENTS THAT NEED TO BE SUPPORTED - FASTEN CANTILEVERED ELEMENTS TO CHANNEL OR PROVIDE UNISTRUT AS REQ'D. TO PROVIDE ADEQUATE SUPPORT - FIELD VERIFY AND
COORDINATE EQUIPMENT HEIGHT AND SUPPORT HEIGHTS AS REQ'D.
NOTE THAT ADDITIONAL ENGINEERING WILL BE REQUIRED FOR EQUIPMENT OVER 300 POUNDS.
FI
EL
D V
ER
IF
Y
C O
O R
D . A
S R
EQ
'D
WALL - TYPE VARIES BY PROJECT
TERMINATION BAR AT TOP OF SPM FLASHING
MEMBRANE - PROVIDE COMPATIBLE
SEALANT BEHIND MEMBRANE AND OVER TOP
OF TERMINATION BAR - FASTEN @ 8" O.C.
SINGLE PLY ROOFING SYSTEM -
VARIES PER PROJECT
DRAINAGE PLANE / AIR & MOISTURE
BARRIER OVER SHEATHING AS OCCURS
EXTERIOR CLADDING / RAIN-SCREEN
AS OCCURS - VARIES BY PROJECT
DECK AS OCCURS - VARIES PER
PROJECT
1' -0
"M
IN
. T O
B O
TT
O
M O
F W
AL
L
PA
N
EL
8" M
IN
1' -0
"M
IN
. T O
B O
TT
O
M O
F W
AL
L
PA
N
EL
ROOF @ RAIN SCREEN / CLADDING
/ INTERIOR INSULATION
PREFINISHED, FRY SPRINGLOK 2-PIECE
"MASONRY REGLET MA" W/ 4" LEG (OR
APPROVED EQUAL) TO BE RUN BENEATH THE
CLADDING / RAIN-SCREEN SYSTEM - FLATTEN
AND REBEND LEG OF REGLET TO TURN UP FACE
OF SHEATHING / DRAINAGE PLANE AS SHOWN
8" M
IN
SECONDARY APPLICATION OF AIR &
MOISTURE BARRIER TO BE INSTALLED AS
SHOWN (AFTER COUNTERFLASHING
SYSTEM(S) HAVE BEEN INSTALLED)
PRIMED COVER BOARD & MINERAL WOOL
INSULATION BOARD (OR OTHER INSULATION AS
OCCURS) - MUST RUN FULL HEIGHT TO
UNDERSIDE OF WALL CLADDING ABOVE -
DEPTH AS REQ'D TO MATCH EXTERIOR
CLADDING / RAIN-SCREEN ABOVE
"Z" GIRTS OR OTHER SOLID SUBSTRATE
FOR ATTACHMENT OF TERM BAR TO WALL
VERIFY
ROOF @ RAIN SCREEN / CLADDING
/ EXTERIOR INSULATION
IN
SU
LA
TE
D
N O
N
-IN
SU
LA
TE
D
PREFINISHED, FRY 2-PIECE, "STUCCO REGLET STX"
AND COUNTERFLASHING (OR APPROVED EQUAL)
NOTE THAT THE INTENT OF THIS DETAIL IS TO
ACHIEVE A COUNTER-FLASHING SYSTEM THAT WILL
ALLOW FOR FUTURE RE-ROOFING WITHOUT
NEEDING TO REMOVE OR NEGATIVLY AFFECT THE
BUILDINGS WALL CLADDING / RAIN SCREEN SYSTEM
ADDITIONAL FLASHING AS OCCURS (IF REQ'D. BY
WALL CLADDING / RAIN SCREEN SYSTEM)
B1 TYPICAL VENT/PIPE/CONDUIT FLASHING DETAIL
SCALE: 3" = 1'-0"
D1 REMOVABLE FLASHING AT WALL BASE
SCALE: 3" = 1'-0"
A1 EQUIPMENT CURB AND SUPPORT DETAILS
SCALE: 3" = 1'-0"
TYP. EQUIPMENT CURB
18" MIN.
CURB TO PENETRATION
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
AE502
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
B2 WARRANTY SIGN
SCALE: 3" = 1'-0"
A2 TYPICAL BASE DETAIL
SCALE: 3" = 1'-0"
7"
8" M
IN
1' -8
"M
IN
1'-0"
1' -0
PLAN VIEW OF STEEL PLATE
PIPE IS TO BE LOCATED A
MIN. OF 18" AWAY FROM
UNIT THAT IT IS SERVING
1"
CAUTION
THIS ROOF IS UNDER WARRANTY UNTIL (INSERT YEAR) WITH
(INSERT MANUFACTURER) . ALL ACCESS IS TO BE RESTRICTED
WITHOUT FACILITIES MANGER'S PERMISSION & LOG ENTRY. REPAIR
WORK, IF NECESSARY, SHOULD BE PERFORMED ONLY BY AN
AUTHORIZED APPLICATOR. FOR LEAK REPAIRS, CONTACT (INSERT
MANUFACTURER) @ (INSERT MANUFACTURER WARRANTY CLAIM
DEPARTMENT PHONE NUMBER) AND PROVIDE THEM WITH
WARRANTY NUMBER. QUESTIONS REGARDING THIS ROOF OR ANY
POTENTIAL WORK PERTAINING TO THIS ROOF, PLEASE CONTACT
BUILDING MANAGER @ DFCMROOF@UTAH.GOV
WARRANTY #:
WARRANTY TYPE:
INSTALLATION DATE:
MANUFACTURER'S
ADDRESS:
ROOFING CONTRACTOR:
CONTRACTOR
TELEPHONE #:
CONTRACTOR ADDRESS:
ROOF MEMBRANE TYPE:1'
-4
1'-2"
IF INTERIOR INSTALLATION
OCCURS:
.060 ALUMINUM SIGN WITH UV
INHIBITED, SCREEN PRINTED
BACKGROUND, LETTERING
AND GRAPHICS - PROVIDE
WITH RADIUSED CORNERS
AND NO SHARP EDGES
IF EXTERIOR INSTALLATION
OCCURS:
.060 (DARK BRONZE)
ALUMINUM SIGN WITH LASER
ENGRAVED LETTERING AND
GRAPHICS - PROVIDE WITH
RADIUSED CORNERS AND NO
SHARP EDGES
USE APPROPRIATE
FASTENERS AT EACH
CORNER FOR WALL
TYPE WHERE BEING
INSTALLED
PROVIDE SUBMITTAL ON
FINAL DESIGN OF SIGN -
ALL FINAL VERBIAGE AND
GRAPHICS WILL BE
DETERMINED DURING
THE SUBMITTAL PHASE
1/2"
NOTE: THIS SIGN IS TO BE PROVIDED AND
INSTALLED ON AN INTERIOR WALL NEAR ALL
ROOF ACCESS POINTS - IF INTERIOR
INSTALLATION IS NOT FEASIBLE, EXTERIOR
APPLICATION NEAR AN OBVIOUS ACCESS
LOCATION IS ACCEPTABLE
IF MULTIPLE ROOF WARRANTIES OCCUR OR IF
ROOFING PROJECT IS NOT FOR THE ENTIRE
BUILDING, A SCREEN PRINTED (OR LASER
ENGRAVED) ROOF PLAN TO BE PROVIDED IN THIS
SPACE - THIS IS TO INDICATE THE LOCATIONS OF
THE ROOFING PROJECT TO SHOW WHERE
WARRANTIES APPLY - ARCHITECT SHALL SUPPLY
PLAN DURING THE SUBMITTAL PHASE
A3 PARAPET DETAIL
SCALE: 3" = 1'-0"
C4 GOOSENECK PIPE DETAIL
SCALE: 3" = 1'-0"
TYPICAL
HEAT WELDED FLASHING
2"
MIN.
2"
MIN.ROOFING MEMBRANE - VARIES
BY PROJECT
ROOF DECK VARIES BY
PROJECT
RIGID INSULATION -
VARIES BY PROJECT
8" M
IN
ROUTE AUTOMATIC DRAIN
TO NEAREST MOP SINK,
FLOOR SINK, OR FUNNEL
DRAIN - PROVIDE 2" AIR GAP
1'-0"
1' -0
PLAN VIEW OF STEEL PLATE
12"x12"x1/4" STEEL PLATE - WELD PIPE TO PLATE -
ATTACH PLATE TO DECK WITH (12) #14 STS (OR
APPROPRIATE FASTENERS FOR DECK TYPE AS
DIRECTED BY A STRUCTURAL ENGINEER)
CAPPED, 2" DIA. x 3/16" STEEL
PIPE (GALVANIZED) - WELDED TO
STEEL BASE PLATE -
COORDINATE LOCATION AND
HEIGHT WITH OWNER AND DISH
SUPPLIER AS REQ'D. - NOTE:
SEAL ANY HOLES OR OTHER
PENETRATIONS USED FOR THE
GALVANIZING PROCESS
AS
R
EQ
'D
C
O O
R D
. W
EQ
U
IP
M
EN
T
R
EQ
U
IR
EM
EN
TS STAINLESS STEEL
CLAMPING RING
CONT. BEAD OF APPROVED
SEALANT
FIELD FABRICATED METAL
HOOD
PRE-MOLDED SPM
PIPE FLASHING
2" MIN. WELDED SPLICE
FASTENER
2"
ROOF DECK VARIES BY
PROJECT
C2 SATELLITE PLATFORM DETAIL
SCALE: 3" = 1'-0" C3 HYDRANT DETAIL
SCALE: 3" = 1'-0"
3/4"
FIELD MEMBRANE - RUN
OVER EDGE OF ROOF
AS SHOWN
6" WIDE / CONT. FLASHING
MEMBRANE WELDED TO FIELD
MEMBRANE & COATED METAL
NAILERS / SUBSTRATE
24 GA. PREFINISHED FASCIA
METAL - INSTALL OVER
HOLD-DOWN CLIP AND
CRIMP TOP OVER COATED
METAL
CONTINUOUS 24 GA. COATED METAL / HOLD DOWN CLIP - FASTEN (TWO ROWS) @
6" O.C. W/ CORROSION RESISTANT, BARBED ANNULAR RING, OR SCREW SHANK
NAIL - LENGTH TO ACHIEVE APPROX. 1-1/4" PENETRATION INTO NAILER - FASTEN
BOTTOM ROW OF NAILS NEAR BEND AT HOLD DOWN CLIP FOR INCREASED UPLIFT
RESISTANCE - PROVIDE A CONTINUOUS BEAD OF SEALANT BEHIND THE HOLD
DOWN CLIP / COATED METAL
CONT. BEAD OF
SEALANT
4" 2"
4" O.C.
4" MIN.
24 GA. CONT. COATED
METAL
MIN. 1 1/4" GALVANIZED
ANNULAR RING NAILS
FASTENED AT 4" O.C.
STAGGERED
4" WIDE FLASHING STRIP HEAT
WELDED IN PLACE
2" WIDE ALUMINUM
TAPE OVER JOINT
1/4" GAP
1/4"
NOTE THAT THIS COATED METAL IS
TO BE COVERED UP BY A
PREFINISHED EDGE METAL COVER6" O.C. MAX
MIN. 1 1/4" GALVANIZED
ANNULAR RING NAILS
FASTENED AT 4" O.C.
SI
ZE
T O
C O
VE
R
N
AI
LE
R
S
1" 3/
4"
B3 PARAPET DETAILS
SCALE: 6" = 1'-0"
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
AE503
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
LINE SET OR OTHER SIM.
PENETRATIONS THROUGH ROOF
COATED METAL
ENCLOSURE WITH ALL
SEAMS / JOINTS /
FASTENERS ETC. FULLY
COVERED /
WATERPROOFED WITH
HEAD WELDED
MEMBRANE
AT BASE OF ENCLOSURE,
PROVIDE INSULATION THAT IS
EQUIVALENT TO THE R-VALUE
OF THE ROOF SYSTEM
ROOFING MEMBRANE - VARIES
BY PROJECT
RIGID INSULATION -
VARIES BY PROJECT
ROOF DECK VARIES BY
PROJECT
2" AS REQ'D. 2"
2"
AS
R
EQ
'D
2"
PLAN VIEW
FASTEN FLANGES OF ENCLOSURE TO DECK WITH
(12) #14 STS (OR APPROPRIATE FASTENERS FOR
DECK TYPE)
1' -8
"M
IN
4" AS REQ'D.
REMOVABLE COATED METAL
CAP - FASTEN TO
ENCLOSURE W/ (2 PER SIDE
ON 3 SIDES) HIGH-DOMED,
CAPPED, GASKETED
FASTENERS - ALL SEAMS /
JOINTS THAT ARE NOT
REQUIRED FOR REMOVAL OF
CAP ARE TO BE FULLY
WATERPROOFED WITH HEAT
WELDED MEMBRANE
NOTE THAT THIS EDGE OF THE CAP
IS TO EXTEND 4" BEYOND THE FACE
OF THE ENCLOSURE TO SHIELD
LINE SET PENETRATION FROM
WEATHER - PROVIDE HEMMED DRIP
EDGE AS SHOWN
2"
FASTEN PARTIAL COATED
METAL PIPE EXTENSION TO
ENCLOSURE - SEE PHOTO
ABOVE (SIM.) - COVER ALL
FASTENERS / JOINTS WITH
WELDED MEMBRANE
NOTCH CAP WHERE PIPES
PENETRATE (IF REQ'D.)
HEAT WELD FLASHING
TO COATED METAL
ENCLOSURE
NOTE THAT PITCH POCKETS
ARENOT AN ACCEPTABLE
METHOD OF WATER-PROOFING
BASE OF PIPES
SEAL OR FOAM IN AND
AROUND OPENINGS TO
FURTHER PROTECT THE
OPENING FROM THE
ELEMENTS AND INSECTS ETC.
LINE SET OR OTHER SIM.
PENETRATIONS THROUGH
ROOF
FASTEN FLANGES OF ENCLOSURE
TO DECK WITH (12) #14 STS (OR
APPROPRIATE FASTENERS FOR
DECK TYPE)
NOTE THAT LINE SET
MUST ENTER THE
ENCLOSURE DRAPING
UPWARDS AS SHOWN
NOTE (TYPICAL):
ALL EXISTING LINE SETS MUST
BE REPLACED WITH NEW -
PROVIDE ADDITIONAL LENGTH
OF LINE SET AS REQ'D. TO
PROPERLY WORK WITH NEW
ENCLOSUREENCLOSURE SHOWN IN PHOTO FOR REFERENCE ONLY -
NOTE THAT ALL METAL MUST BE COATED METAL, (NOT
GALVANIZED METAL)
NOTE (TYPICAL):
LOCATE NEW LINE SET
ENCLOSURES A MINIMUM OF 18"
AWAY FROM THE UNIT BEING
SERVED
8" M
IN
ADJUSTABLE BASE / SUPPORT
NOTE:
NO WELDING WILL BE ALLOWED ON
THE ROOF - WELDING SHALL BE DONE
IN THE PARKING LOT OR IN A SHOP
1/4
1/4
1/8
BOTH ENDS
1/4
C2 ELEVATED EQUIPMENT PLATFORM
SCALE: 3" = 1'-0" C3 LINE SET ENCLOSURE DETAIL
SCALE: 3" = 1'-0"
B3 NEW ROOF VS EXISTING ROOF
SCALE: NTS
A EXISTING CONDITION @ CONCRETE DECK B NEW CONDITION @ CONCRETE DECK
TYPICAL NOTE: ALL EXISTING LINE SETS AND
ELECTRICAL LINES / CONNECTIONS (AS OCCUR)
ARE TO BE REPLACED WITH NEW - WITH THE
EXCEPTION OF RIGHT AT THE EQUIPMENT
LOCATION, ELECTRICAL LINES AND JUNCTION
BOX'S THAT ARE RUN ABOVE THE ROOF, AND OR
DECK, ARE TO BE REPLACED AND RE-RUN
BENEATH THE DECK BACK TO THE NEAREST
JUNCTION OR ELECTRICAL BOX - NO FLEXIBLE
ELECTRICAL CONDUIT WILL BE ALLOWED LOWER
THAN 12" ABOVE THE FINISHED ROOF SURFACE -
ALL ELECTRICAL WORK MUST BE DONE TO NEC
STANDARDS
NOTE THAT WALK PADS ARE TO BE
PROVIDED AT ALL 4 SIDES OF
THESE ELEVATED PLATFORMS
EQUIPMENT PLATFORM 3D
C1 ELEVATED EQUIPMENT PLATFORM
SCALE: 1-1/2" = 1'-0"
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
AE504
MARK DESCRIPTIONDATE
SHEET TITLE
DESIGNED BY:
DRAWN BY:
DATE:
CAD DWG FILE NO:
DESIGN SEQUENCE PROJECT NO:
AGENCY PROJECT NO:
DWG TYPE:
ARCHITECTURAL PHASE:
350 South 200 East, #106 Salt Lake City, Utah 84111
P: 801.596.0691 DesignUtah.com
MAY 14, 2026
27006700
2605.01
SNOW COLLEGE
TRADES BLDG
ROOF REPLACEMENT
325 W 100 N, Ephraim, UT 84627
PERMIT SET
Building Official Stamp
Consultant Info
Engineer Stamp
A3 PIPE GUARD RAIL
SCALE: 3/4" = 1'-0"
A
A2 ROOF LADDER AND HATCH
SCALE: 3/4" = 1'-0"
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
06/10/2026
| Sheets and Views |
| 2018 Sheet Plot File-GI001 |
| 2018 Sheet Plot File-GI002 |
| 2018 Sheet Plot File-AS101 |
| 2018 Sheet Plot File-AE101 |
| 2018 Sheet Plot File-AE501 |
| 2018 Sheet Plot File-AE502 |
| 2018 Sheet Plot File-AE503 |
| 2018 Sheet Plot File-AE504 |
File details come from the government source that posted it. Updated .