7-2-CS26096-27070030-Approved Plans.pdf
PDF 5 MB Posted
- Solicitation number
- CS26096
- Issued by
- Utah
About this file
Approved Plans Summary
This is an Approved Plans document for a Stage II construction project administered by the State of Utah Division of Facilities Construction and Management (DFCM) on behalf of the Department of Alcoholic Beverage Services. The project involves replacing the failing fiber cement facade of the Farmington Liquor Store with a metal panel facade system. The project is identified as #27070030 and is restricted to contractors who have completed Stage I prequalification and currently maintain active status on the DFCM Prequalified Contractors list. The approved plans document serves as the technical foundation for the bidding process, providing contractors with detailed specifications, drawings, and construction requirements necessary to prepare accurate bids and execute the work.
The project carries a construction cost estimate of $600,000. As a Stage II Invitation to Bid, this solicitation is limited to prequalified contractors only, ensuring that only experienced and vetted firms are permitted to submit proposals. The approved plans contained in this document establish the baseline scope of work, design standards, and technical specifications that all bidders must follow. Contractors must review these plans thoroughly during the bidding phase to ensure compliance and accurate cost estimation for the facade replacement project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UTAH DEPARTMENT OF ALCOHOLIC
BEVERAGE SERVICES
FARMINGTON STORE FACADE
REPLACEMENT
579 North Lagoon Drive Farmington, Utah 84025
CONSTRUCTION DRAWINGS
17 June 2026
Nexus Project #: 26028 DFCM Project #: 27070030
CONTACT: E-MAIL:
PHONE: INTERNET:
ARCHITECT
Architectural Nexus 2505 East Parleys Way
Salt Lake City, UT 84109
801.924.5000
Stephen Springer sspringer@archnexus.com www.archnexus.com
CONTACT: E-MAIL:
PHONE: INTERNET:
PROJECT MANAGER
Utah DFCM 4110 State Office Building Salt Lake City, UT 84114
Eric Stokes ebstokes@utah.gov dfcm.utah.gov
CONTACT: E-MAIL:
PHONE: INTERNET:
OWNER
Utah DABS 1625 South 900 West
Salt Lake City, UT 84104
Tom Gibbs tomgibbs@utah.gov abs.utah.gov
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
THOMAS PETERSON
06/25/2026
MATCH LINE
SEE A-222
MATCH LINE TAG
EXISTING WALL TO REMAIN
WALL TO BE DEMOLISHED
NEW WALL
BREAK LINE
CENTER LINE SYMBOL
0'
REVISION DESIGNATION
ELEVATION SYMBOL
T.O. WALL
100'-0"
REVISION NUMBER
ELEVATION ABOVE DATUM
ELEVATION DESCRIPTION
DRAWING SYMBOL LEGEND
CASEWORK TYPE DESIGNATION
CDS NUMBER -
AWS STANDARD CDS NUMBERING SYSTEM
WIDTH
HEIGHT
DEPTH
NORTH ARROW
PLAN NORTH
GRAPHIC SCALES
ROUND BREAK LINE
REVISION CLOUD
SLOPE INDICATION
1/2" / 12"
DETAIL REFERENCE
A2 A-401
A1
A3
INTERIOR ELEVATIONS
DETAIL NUMBER
SHEET NUMBER
A1
A-501
DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
A1
A-201
EXTERIOR ELEVATION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1
A-302
WALL SECTION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1
A-301
BUILDING SECTION REFERENCE
DETAIL NUMBER
SHEET NUMBER
Room name
XX000X
ROOM DESIGNATION (FLOOR PLAN)
ROOM NUMBER
ROOM NAME (WHERE SHOWN)
A1
A-301
DETAIL NUMBER
SHEET NUMBER
00001
GLASS TYPE DESIGNATION
KEYED NOTE DESIGNATION
WALL TYPE DESIGNATION
EQUIPMENT DESIGNATION
WINDOW DESIGNATION
DOOR DESIGNATION
EQUIPMENT NUMBER
WALL TYPEXXX
MATERIAL TYPE DESIGNATION
SEE AF601 FINISH LEGEND
12" 1/2"
RISE
RUN
TRUE NORTHA1
A-301
302M 36"
34" 16"
(Modification Description)
('M' DENOTES MODIFICATION - SEE
"MODIFICATION DESCRIPTION" AT
BOTTOM OF TAG)
?P01 FINISH NUMBER
CL00
XX'-XX"
CEILING TYPE DESIGNATION
CEILING HEIGHT ABOVE FINISH FLOOR
CEILING TYPE
CL
X000X DOOR NUMBER
G1 GLASS TYPE
W00 WINDOW TYPE
MULLION TYPE DESIGNATION
?SM00
A1
PRECAST ELEMENT DESIGNATION
PRECAST NUMBER
4' 8' 16'
TOILET ROOM ACCESSORY DESIGNATION
TM TOILET ROOM ACCESSORY TYPE
08:0801 KEY NOTE NUMBER
DIVISION
SECTION
SEQUENCE
N
MULLION TYPE
LIST OF ABBREVIATIONS
THE PRECEDING LIST OF ABBREVIATIONS
IS PRESENTED AS A GENERAL GUIDE AND
DOES NOT NECESSARILY SHOW ALL
ABBREVIATIONS USED. OTHER
GENERALLY ACCEPTED ABBREVIATIONS
MAY BE FOUND AMONG THE DRAWINGS -
SOME ABBREVIATIONS SHOWN ABOVE
MAY NOT BE USED WITHIN THIS DRAWING
SET.
A
A/C AIR CONDITIONING
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT
@ AT
B
BD BOARD
BLDG BUILDING
BO BOTTOM OF
C
C CELSIUS
CH COAT HOOK
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CG CORNER GUARD
CI CONTINUOUS INSULATION
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CT CERAMIC TILE
CTJ CONSTRUCTION JOINT
CUH CABINET UNIT HEATER
D
D DEEP
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DWGS DRAWINGS
E
EA EACH
EJ EXPANSION JOINT
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EOS EDGE OF SLAB
ERD EXISTING ROOF DRAIN
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F
F FAHRENHEIT
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FDC FIRE DEPARTMENT CONNECTION
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FG FINISH GRADE
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FND FOUNDATION
FO FINISHED OPENING
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FRG FIBER REINFORCED GYPSUM
FSP FIRE STANDPIPE
FT FEET
FV FIELD VERIFY
G
GA GAUGE
GALV GALVANIZED
GFRC GLASS-FIBER-REINFORCED
CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
H
H HIGH
HB HOSE BIBB
HDR HEADER
HM HOLLOW METAL
HPT HIGH POINT
HR HOUR
HT HEIGHT
I
ID INSIDE DIAMETER; INSIDE DIMENSION
IN INCH
INFO INFORMATION
INT INTERIOR
J
JAN JANITOR
K (NOT USED)
L
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
M
MACH RM MACHINE ROOM
MAX MAXIMUM
MFR MANUFACTURER
MECH MECHANICAL
MEZZ MEZZANINE
MIN MINIMUM
MO MASONRY OPENING
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER;
OUTSIDE DIMENSION
OFD OVERFLOW DRAIN
OFIC OWNER FURNISHED CONTRACTOR
INSTALLED ELEMENT
OH DR OVERHEAD DOOR
OPH OPPOSITE HAND
OPP OPPOSITE
ORIG ORIGINAL
P
P LAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PR PAIR
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PVC POLYVINYL CHLORIDE
Q
QT QUARRY TILE
R
R RISER OR RADIUS
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIDGERATOR
REQD REQUIRED
REV REVISION
RH RELATIVE HUMIDITY
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RWL RAIN WATER LEADER
S
S SMOKE DETECTOR
SAM SELF ADHESIVE MEMBRANE
SCHED SCHEDULE
SECT SECTION
SIM SIMILAR
SPEC SPECIFICATION
SS STAINLESS STEEL
STD STANDARD
STRUCT STRUCTURAL
T
T TREAD
TEL TELEPHONE
TEMP TEMPORARY
THK THICK
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB; TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
TO TOP OF
U
UL UNDERWRITER'S LABORATORIES
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W
W/ WITH
W/O WITHOUT
WD WOOD
WH WALL HYDRANT
WP WORKING POINT
WRB WEATHER RESISTIVE BARRIER
X,Y,Z (NOT USED)
CAST-IN-PLACE CONCRETE
CONCRETE MASONRY UNIT
PRECAST CONCRETE / GLASS FIBER
REINFORCED CONCRETE (GFRC)
STEEL STUDS
WOOD STUDS
BRICK VENEER
RIGID INSULATION
BATT INSULATION
CONTINUOUS MATERIAL
NON CONTINUOUS MATERIAL (BLOCKING)
GYPSUM BOARD
PLYWOOD
GRAVEL
UNDISTURBED EARTH
HATCH LEGEND
NOTE: HATCHING ANGLES MAY VARY DUE TO ANGLE OF WALL DRAWN, WHILE HATCHING PATTERN REMAINS SIMILAR.
BACKFILL OR FILL
EXTERIOR SHEATHING
S
IT
E Farmington Liquor Store 579 North Lagoon Drive Farmington, UT 84025
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJECT #:
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
SMS
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© Architectural Nexus, Inc. 2021
654321
E
D
C
B
A
/1
/2
:4
:4
P M
GENERAL
INFORMATION
KM
D F
C M
P ro je c t
U T
A H
D E
P A
R T
M E
N T
O F
A L
C O
H O
L
IC
B E
V E
R A
G E
S E
R V
IC
E
S
26028
17 June 2026
F A
R M
IN
G
T O
N S
T O
R E
F A
C A
D E
R E
P L
A C
E M
E N
T
CONSTRUCTION
DRAWINGS
G-002
N o rt h L a g o o n D ri v e
F a rm in g to n
U ta h
NATIONAL ELECTRICAL CODE
INTERNATIONAL FIRE CODE
INTERNATIONAL BUILDING CODE
ACCESSIBILITY CODE
DESIGN CRITERIA
APPLICABLE CODES OTHER CRITERIA
DEFERRED SUBMITTALS
ADDITIONAL REQUIREMENTS
REQUIRED DOCUMENTS FOR FINAL APPROVAL
INTERNATIONAL EXISTING BUILDING CODE
2021 EDITION
2021 EDITION
2021 EDITION
ICC/ANSI A117.1-2009
2023 EDITION
CURRENT EDITIONZONING ORDINANCE: FARMINGTON CITY
DFCM DESIGN GUIDELINES
LOCATION
APPROVALS
Date DateTom Gibbs State of Utah Department of Alcoholic Beverage Control
Eric Stokes State of Utah Division of Facilities Construction & Management
GENERAL:
G-001 COVER SHEET
G-002 GENERAL INFORMATION
ARCHITECTURAL:
A-101 SITE & FLOOR PLAN
A-201 ELEVATIONS - DEMO
A-202 ELEVATIONS
A-203 ENLARGED ELEVATIONS & DETAILS
A-501 SECTION DETAILS
SHEET INDEX
# Date Revision
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
UP
A-202
B2
A-202
C3
A-202
A3
A-202
D2
A-201 B1
A-201
A1
A-201
C1
A-201
B2
A-201
C3
A-201
A3
A-201
D2
A-201D1
A-202D1
A-202 B1
A-202
A1
A-202
C1
DESIGNATED
CUSTOMER ENTRANCE
DESIGNATED
EXIT
TRANSFORMER PAD - PROTECT
IN PLACE
ENCLOSED DUMPSTER -
MAINTAIN SERVICE ACCESS
EMPLOYEE ENTRANCE - PROVIDE
OVERHEAD PROTECTION & BARRIERS
TO MAINTAIN PEDESTRIAN ACCESS &
EGRESS
CONCRETE SIDEWALK
CONCRETE CURB &
GUTTER
CONCRETE CURB &
GUTTER
PLANTING AREA
PLANTING AREA
PLANTING
AREA
FIRE HYDRANT - MAINTAIN
EMERGENCY VEHICLE ACCESS
FDC - MAINTAIN EMERGENCY
VEHICLE ACCESS
DABC BLDG FOOTPRINT
P
LA
N
TI
N G
P
LA
N
TI
N G
CONC. RAMP -
MAINTAIN CUSTOMER
ACCESS
STAIR
STOP SIGN
PRIMARY CUSTOMER ENTRANCE -
PROVIDE OVERHEAD PROTECTION
& BARRIERS TO MAINTAIN
PEDESTRIAN ACCESS & EGRESS
COORDINATE CONSTRUCTION
ACTIVITIES OVER RECEIVING
AREA WITH OWNER
PROVIDE OVERHEAD
PROTECTION & BARRIERS
TO MAINTAIN PEDESTRIAN
ACCESS & EGRESS
EXIT
EXIT
EXIT
EXIT
PROPOSED CONTRACTOR LAY DOWN AREA
PROTECT
LANDSCAPING/PLANTS
& IRRIGATION
PROTECT
LANDSCAPING/PLANTS
& IRRIGATION
PROTECT
LANDSCAPING/PLANTS
& IRRIGATION, TYPICAL
P R
O
TE
C T
LA
N
D S
C A
P
IN
G /P
LA
N
TS
IR
R
IG
A
TI
O N
, T Y
P
IC
A L
P R
O
TE
C T
LA
N
D S
C A
P
IN
G /P
LA
TS
IR
R
IG
A
TI
O N
, T Y
P
IC
A L
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJECT #:
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
SMS
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© Architectural Nexus, Inc. 2021
654321
E
D
C
B
A
/1
/2
:4
:5
P M
SITE & FLOOR
PLAN
Author
D F
C M
P ro je c t
U T
A H
D E
P A
R T
M E
N T
O F
A L
C O
H O
L
IC
B E
V E
R A
G E
S E
R V
IC
E
S
26028
17 June 2026
F A
R M
IN
G
T O
N S
T O
R E
F A
C A
D E
R E
P L
A C
E M
E N
T
CONSTRUCTION
DRAWINGS
A-101
N o rt h L a g o o n D ri v e
F a rm in g to n
U ta h
3/32" = 1'-0"A-101
C3 FLOOR PLAN - FOR REFERENCE ONLY
N
1/16" = 1'-0"A-101
A1 SITE PLAN
# Date Revision
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
LEVEL 01
100' - 0"
FINISH
117' - 6"
(TYP)02:DC2(TYP)02:DC2
(TYP)02:EX1
(TYP)02:EX1
02:DC3
A6
A-501
______ A6
A-501
B6
A-501
D6
A-501
E6
A-501
B6
A-501
D6
A-501
D6
A-501
A-203
D1
LEVEL 01
100' - 0"
FINISH
113' - 0"
(TYP)02:DC2
(TYP)02:EX1
(TYP)02:EX1
01:CD1
E6
A-501
D6
A-501
A6
A-501
______ A6
A-501
D6
A-501
A-203
D1
LEVEL 01
100' - 0"
FINISH
117' - 0"
(TYP)02:DC2
02:EX1
E6
A-501
A6
A-501
D6
A-501
D6
A-501
A-203
D1
FINISH
113' - 6"
117' - 0"
(TYP)02:DC2
(TYP)02:EX1
02:DC3
01:CD1
E6
A-501
D6
A-501
A6
A-501
A6
A-501
A-203
D1
A. PROTECT WALLS, CEILINGS, FLOORS AND OTHER
EXISTING FINISH WORK THAT ARE TO REMAIN OR
THAT ARE EXPOSED DURING SELECTIVE
DEMOLITION OPERATIONS
B. PATCH AND REPAIR DAMAGE IN WALLS, CEILINGS,
AND FLOORS RESULTING FROM DEMOLITION OF
EXISTING ITEMS OR CONSTRUCTION OF NEW
ITEMS AND/OR REPLACE WITH NEW TO MATCH
EXISTING. CLEAN AND PREPARE TO RECEIVE
NEW FINISH.
C. PROTECT ADJACENT AREAS FROM DUST AND
DEBRIS DURING SELECTIVE DEMOLITION
OPERATIONS.
D. TRANSPORT DEMOLISHED MATERIALS OFF
OWNER'S PROPERTY AND LEGALLY DISPOSE OF
DEBRIS.
E. FIELD VERIFY EXISTING CONDITIONS AND THEIR
COMPATIBILITY WITH NEW CONSTRUCTION PRIOR
TO THE COMMENCEMENT OF WORK.
COORDINATE DISCREPANCIES WITH ARCHITECT.
F. CLEAN ADJACENT IMPROVEMENTS OF DUST, DIRT,
AND DEBRIS CAUSE BY SELECTIVE DEMOLITION
OPERATIONS. RETURN ADJACENT AREAS TO
CONDITION EXISTING BEFORE SELECTIVE
DEMOLITION OPERATIONS BEGAN.
G. COORDINATE DISCREPANCIES WITH ARCHITECT
PRIOR TO PROCEEDING WITH WORK.
H. ALL EXPOSED UNFINISHED STEEL TO BE PAINTED
UNLESS DIRECTED BY ARCHITECT.
I. PORTIONS OF THE BUILDING AFFECTED BY
DEMOLITION AND EXPOSED TO WEATHER OR
MOISTURE REQUIRE TEMPORARY PROTECTION
UNTIL NEW CONSTRUCTION IS COMPLETE.
GENERAL NOTE - DEMOLITION
PLAN
02:DC2
01:IW1
INTERIOR EXTERIOR
02:DC2
26:LF1
02:DC4
02:DC2
01:IW1
D2
A-501
E2
A-501
02:DD1
(TYP)02:DC2
01:IW1
D2
A-501
E2
A-501
INTERIOREXTERIOR
26:LF1
02:DC2
02:DD1
26:LF1
02:DC2
02:DD1
1/4" = 1'-0"A-201
A1 CHECKOUT AREA (S) DEMO
1/4" = 1'-0"A-201
B1 CHECKOUT AREA (E) DEMO
1/4" = 1'-0"A-201
C1 CHECKOUT AREA (W) DEMO
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJECT #:
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
SMS
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© Architectural Nexus, Inc. 2021
654321
E
D
C
B
A
/1
/2
:4
:5
P M
ELEVATIONS -
DEMO
KM
D F
C M
P ro je c t
U T
A H
D E
P A
R T
M E
N T
O F
A L
C O
H O
L
IC
B E
V E
R A
G E
S E
R V
IC
E
S
26028
17 June 2026
F A
R M
IN
G
T O
N S
T O
R E
F A
C A
D E
R E
P L
A C
E M
E N
T
CONSTRUCTION
DRAWINGS
A-201
N o rt h L a g o o n D ri v e
F a rm in g to n
U ta h
1/8" = 1'-0"A-201
B2 BUILDING ELEVATION (E) - DEMO
1/8" = 1'-0"A-201
C3 BUILDING ELEVATION (N) - DEMO
1/8" = 1'-0"A-201
A3 BUILDING ELEVATION (S) - DEMO
1/8" = 1'-0"A-201
D2 BUILDING ELEVATION (W) - DEMO
SHEET KEYNOTES
01:CD1 COORDINATE CONSTRUCTION ACTIVITIES
SO AS TO ALLOW FOR DELIVERY
OPERATIONS TO REMAIN INTACT
01:IW1 ALL INTERIOR WORK TO BE PERFORMED
OUTSIDE OF NORMAL BUSINESS
OPERATING HOURS (11AM - 10PM)
02:DC2 DEMO EXISTING FACADE PANELS & FABRIC
02:DC3 REMOVE EXISTING SIGNAGE. PROTECT,
STORE, & REINSTALL AFTER NEW FACADE
HAS BEEN INSTALLED. REPLACE ANY
DAMAGED LETTERS, SUPPORTS,
SEALANT/CAULKING NEEDED TO BE
REINSTALLED LIKE NEW.
02:DC4 REMOVE CART RAIL, PROTECT, AND
RE-INSTALL AT SAME LOCATION
02:DD1 EXISTING DOORS TO REMAIN, PROTECT
02:EX1 EXISTING FACADE, PROTECT IN PLACE
26:LF1 EXISTING LIGHT FIXTURE PROTECT,
STORE, & REINSTALL AFTER NEW FACADE
& FABRIC HAS BEEN INSTALLED. REPLACE
ANY DAMAGED PIECES, SUPPORTS,
SEALANT/CAULKING NEEDED TO BE
REINSTALLED LIKE NEW.
1/4" = 1'-0"A-201
D1 MAIN ENTRY (E) DEMO
# Date Revision
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
LEVEL 01
100' - 0"
(TYP)26:LF1
A-203
D4
A-203
B4
(TYP)02:DC3 (TYP)06:FN4
(TYP)06:FN4
(TYP)06:FN5
+/- 7' - 0 1/4"
02:EX1
P A
N E
L R
E
TU
R
FO
LD
LI
N E
P A
N E
L R
E
TU
LI
N E
A-202
D1
E3
A-501
D3
A-501
D3
A-501
D3
A-501
A3
A-501
______ A3
A-501
______ A-203
C4
B3
A-501
B3
A-501
A1
A-501
A1
A-501
A1
A-501
______A1
A-501
A1
A-501
A1
A-501
A1
A-501
B1
A-501
B1
A-501
LEVEL 01
100' - 0"
06:FN4
02:DC3
(TYP)06:FN5
02:EX1
02:EX1
+/- 1' - 5 7/8" +/
- 1
P A
N E
L R
E
TU
LI
N E
P A
N E
L R
E
TU
LI
N E
E3
A-501
D3
A-501
______ D3
A-501
A3
A-501
A1
A-501
______ A1
A-501
______A1
A-501
B1
A-501
B1
A-501
LEVEL 01
100' - 0"
02:RD1
A-203
A4
02:DC3
+/- 2' - 11"
01:AL1 (TYP)06:FN4
(TYP)02:EX1
(TYP)06:FN5
P A
N E
L R
E
TU
LI
N E
P A
N E
L R
E
TU
LI
N E
P A
N E
L R
E
TU
LI
N E
06:FN4
A-202
C1A3
A-501
D3
A-501
E3
A-501
D3
A-501
A1
A-501
A1
A-501
B1
A-501
B1
A-501
LEVEL 01
100' - 0"
FINISH
113' - 0"
(TYP)02:DC3
(TYP)02:EX1
(TYP)06:FN4 (TYP)06:FN5
1'
0"
+/- 2' - 6"
P A
N E
L R
E
TU
R N
FO
LD
LI
N
E
P A
N E
L R
E
TU
R N
FO
LD
LI
N
E
E3
A-501
D3
A-501
______ D3
A-501
______D3
A-501
B1
A-501
A1
A-501
______ A1
A-501
______A1
A-501
B1
A-501
06:FN4
01:IW1
D1
A-501
E1
A-501
INTERIOREXTERIOR
26:LF1
06:FN4
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
06:FN4
01:IW1
D1
A-501
E1
A-501
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
06:FN4
01:IW1
INTERIOR EXTERIOR
26:LF1
06:FN4P
A
N E
L R
E
TU
R N
FO
LD
L
IN
E
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
26:LF1
02:DD1
06:FN4
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
P A
N E
L R
E
TU
R N
FO
LD
L
IN
E
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJECT #:
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
SMS
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© Architectural Nexus, Inc. 2021
654321
E
D
C
B
A
/1
/2
:4
:5
P M
ELEVATIONS
KM
D F
C M
P ro je c t
U T
A H
D E
P A
R T
M E
N T
O F
A L
C O
H O
L
IC
B E
V E
R A
G E
S E
R V
IC
E
S
26028
17 June 2026
F A
R M
IN
G
T O
N S
T O
R E
F A
C A
D E
R E
P L
A C
E M
E N
T
CONSTRUCTION
DRAWINGS
A-202
N o rt h L a g o o n D ri v e
F a rm in g to n
U ta h
1/8" = 1'-0"A-202
B2 BUILDING ELEVATION (E) - NEW FACADE
1/8" = 1'-0"A-202
C3 BUILDING ELEVATION (N) - NEW FACADE
1/8" = 1'-0"A-202
A3 BUILDING ELEVATION (S) - NEW FACADE
1/8" = 1'-0"A-202
D2 BUILDING ELEVATION (W) - NEW FACADE
SHEET KEYNOTES
01:AL1 ALIGN
01:IW1 ALL INTERIOR WORK TO BE PERFORMED
OUTSIDE OF NORMAL BUSINESS
OPERATING HOURS (11AM - 10PM)
02:DC3 REMOVE EXISTING SIGNAGE. PROTECT,
STORE, & REINSTALL AFTER NEW FACADE
HAS BEEN INSTALLED. REPLACE ANY
DAMAGED LETTERS, SUPPORTS,
SEALANT/CAULKING NEEDED TO BE
REINSTALLED LIKE NEW.
02:DD1 EXISTING DOORS TO REMAIN, PROTECT
02:EX1 EXISTING FACADE, PROTECT IN PLACE
02:RD1 EXISTING ROOF DRAIN, PROTECT IN PLACE
06:FN4 NEW FACADE & FABRIC, CONTRACTOR TO
PROVIDE ARCHITECT/OWNER SHOP
DRAWINGS OF FIELD VERIFIED EXISTING
FURRING STRIPS LOCATIONS.
06:FN5 NEW FASCIA COVER; COLOR TO MATCH
METAL PANEL
26:LF1 EXISTING LIGHT FIXTURE PROTECT,
STORE, & REINSTALL AFTER NEW FACADE
& FABRIC HAS BEEN INSTALLED. REPLACE
ANY DAMAGED PIECES, SUPPORTS,
SEALANT/CAULKING NEEDED TO BE
REINSTALLED LIKE NEW.
1/4" = 1'-0"A-202
B1 CHECKOUT AREA (E) NEW FACADE
1/4" = 1'-0"A-202
A1 CHECKOUT AREA (S) NEW FACADE
1/4" = 1'-0"A-202
C1 CHECKOUT AREA (W) NEW FACADE
1/4" = 1'-0"A-202
D1 MAIN ENTRY (E) NEW FACADE
# Date Revision
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
A. ENSURE THAT ALL REQUIRED FIXTURE AND
CABINET CLEARANCES AND OTHER REQUIREMENTS
ARE MAINTAINED PURSUANT TO ADAAG AND ANSI
A117.1. SEE SHEET G701 FOR GENERAL GUIDANCE
ON COMMON MOUNTING HEIGHTS.
B. PROVIDE BLOCKING/BACKING AS NECESSARY FOR
MOUNTING OF WALL-MOUNTED CABINETS,
FIXTURES AND EQUIPMENT PER MANUFACTURERS
RECOMMENDATIONS. COORDINATE THIS
REQUIREMENT THROUGH ALL FLOOR PLANS,
EQUIPMENT PLANS, AND INTERIOR ELEVATIONS.
C. ON ALL EXPOSED CABINET SIDES, INCLUDING KNEE
OPENINGS, PROVIDE FINISHED FACE TO MATCH
CABINET FRONTS . PROVIDE SIDESPLASHES
WHENEVER COUNTERTOPS ARE ADJACENT TO
WALLS.
GENERAL NOTE -
INTERIOR ELEVATION
LEVEL 01
100' - 0"
02:EC1
07:MP3
06:FN3
B3
A-203
A2
A-203
01:FC1
+/- 3' - 4" +/- 1' - 8"
M
ID
P O
IN
T
B E
TW
E
E
P
A N
E L
S E
A M
S
A
LI
G N
02:EC2
GROUND PLANE
LEVEL 01
100' - 0"
02:WH1
02:RD1
B3
A-203
A2
A-203
06:FN4
07:MP3
- 2
A
LI
G N
EQ EQ
MIDPOINT BETWEEN PANELS
LEVEL 01
100' - 0"
02:WH1
06:FN3
07:MP3
B3
A-203
A2
A-203
A
LI
G N
EQ EQM
ID
P O
IN
T
B E
TW
E
E N
P A
N E
L S
E A
M S
LEVEL 01
100' - 0"
B3
A-203
A2
A-203
A
LI
G N
06:FN4
02:WH1
07:MP3
C O
O R
D
IN
TE
W
ID
TH
W
IT
H
P
N E
L
LA
Y O
U T
3" RIGID INSULATION (EXISTING)
7/8" HAT FURRING CHANNEL
(EXISTING)
7/8" HAT FURRING CHANNEL
(EXISTING)
METAL WALL PANELS
7/16" PLYWOOD SHEATHING
(EXISTING)
3/ 8"
FACE-FASTENED METAL WALL
PANEL
METAL WALL PANEL CLIP SYSTEM
FASTENED TO VERTICAL HAT
CHANNEL
FLUID APPLIED MEMBRANE AIR &
WATER BARRIER; VAPOR
IMPERMEABLE. PROTECT IN PLACE
(EXISTING)
METAL WALL PANEL CLIP SYSTEM
FASTENED TO VERTICAL HAT CHANNEL
3" RIGID INSULATION (EXISTING)
3/ 8"
3/ 8"
FACE-FASTENED METAL WALL
PANEL
COMPOSITE SHIM
FACE FASTENED SCREW, COLOR TO
MATCH PANELS
FACE FASTENED SCREW, COLOR TO
MATCH PANELS
COMPOSITE SHIM
UV RESISTANT FABRIC; ATTACHED
PER MFR; BLACK
UV RESISTANT FABRIC; ATTACHED
PER MFR; BLACK
3/8"3/8" METAL WALL PANELS
FACE-FASTENED METAL WALL
PANEL
FACE FASTENED SCREW, COLOR TO
MATCH PANELS
COMPOSITE SHIM
UV RESISTANT FABRIC; ATTACHED
PER MFR; BLACK
PANELS TO RETURN WHEN
ADJACENT TO FACE FASTENED
PANELS
CONTRACTOR TO INFIELD VERIFY EXISTING SIGNAGE DIMENSIONS LAYOUT PRIOR TO REMOVING, REINSTALL AFTER NEW FACADE IS INSTALLED. COORDINATE ANY DISCREPANCIES WITH OWNER/ARCHITECT
1" = 1'-0"A-203
D4 ENLARGED ELEVATION - FDC & CONDUIT
1" = 1'-0"A-203
B4 ENLARGED ELEVATION - SILCOCK 1
1" = 1'-0"A-203
A4 ENLARGED ELEVATION - OVERFLOW DRAIN & SILCOCK
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJECT #:
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
SMS
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© Architectural Nexus, Inc. 2021
654321
E
D
C
B
A
/1
/2
:4
:5
P M
ENLARGED
ELEVATIONS &
DETAILS
BF
D F
C M
P ro je c t
U T
A H
D E
P A
R T
M E
N T
O F
A L
C O
H O
L
IC
B E
V E
R A
G E
S E
R V
IC
E
S
26028
17 June 2026
F A
R M
IN
G
T O
N S
T O
R E
F A
C A
D E
R E
P L
A C
E M
E N
T
CONSTRUCTION
DRAWINGS
A-203
N o rt h L a g o o n D ri v e
F a rm in g to n
U ta h
SHEET KEYNOTES
01:FC1 EXISTING FIRE DEPARTMENT
CONNECTION TO REMAIN, PROTECT IN
PLACE
02:EC1 EXISTING CONDUIT, PROTECT IN PLACE,
CLEARANCE IS LIMITED.
02:EC2 EXISTING DRAIN SPOUT - REMOVE AND
REINSTALL AS NECESSARY TO ACCEPT
NEW FACADE. CONTRACTOR TO
PROVIDE NEW IF DAMAGED DURING
INSTALL
02:RD1 EXISTING ROOF DRAIN, PROTECT IN
PLACE
02:WH1 EXISTING WALL HYDRANT, PROTECT IN
PLACE
05:FS1 FACE FASTENED SCREW, COLOR TO
MATCH PANELS
06:FN3 NEW FACADE & FABRIC
06:FN4 NEW FACADE & FABRIC, CONTRACTOR
TO PROVIDE ARCHITECT/OWNER SHOP
DRAWINGS OF FIELD VERIFIED
EXISTING FURRING STRIPS LOCATIONS.
06:PS2 7/16" PLYWOOD SHEATHING (EXISTING)
07:FMF FLUID APPLIED MEMBRANE AIR &
WATER BARRIER; VAPOR
IMPERMEABLE. PROTECT IN PLACE
(EXISTING)
07:MC7 METAL WALL PANEL CLIP SYSTEM
FASTENED TO VERTICAL HAT CHANNEL
07:MP3 FACE FASTENED METAL PANEL
07:MP4 METAL WALL PANELS
07:MP7 FACE-FASTENED METAL WALL PANEL
07:RI3 3" RIGID INSULATION (EXISTING)
07:SH3 COMPOSITE SHIM
07:UV1 UV RESISTANT FABRIC; ATTACHED PER
MFR; BLACK
09:FC1 7/8" HAT FURRING CHANNEL (EXISTING)
3" = 1'-0"A-203
B3 FACE-FASTENED PANEL VERTICAL SECTION - NEW (TYP.)
3" = 1'-0"A-203
A2 FACE-FASTENED PANEL HORIZONTAL SECTION - NEW (TYP.)
NOT TO SCALEA-203
D6 EXISTING FDC & CONDUIT
NOT TO SCALEA-203
C6 EXISTING SILCOCK 2
NOT TO SCALEA-203
A6 EXISTING OVERFLOW DRAIN & SILCOCK
NOT TO SCALEA-203
B6 EXISTING SILCOCK 1
1" = 1'-0"A-203
C4 ENLARGED ELEVATION - SILCOCK 2
NOT TO SCALEA-203
D1 EXISTING SIGNAGE SPACING- REFERENCE ONLY
# Date Revision
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
DEMO EXISTING CEMENT
FIBER BOARD & FABRIC
EXISTING HAT CHANNEL TO
REMAIN
EXISTING WOOD BOARD TO
REMAIN, PROTECT IN PLACE
1/
4"
NEW METAL PANELS
METAL PANEL CLIP
FASTENED TO EXISTING
HAT CHANNEL
UV RESISTANT FABRIC;
ATTACHED PER MFR; BLACK
3" RIGID INSULATION (EXISTING)
DEMOLISH EXISTING FLASHING
MEMBRANE
T.O. FRAMING
121' - 2"
EXISTING PERSERVATIVE
TREATED WOOD NAILER;
PROTECT FROM DAMAGE
DEMO EXISTING 24 GA.
PREFINISHED FASCIA METAL
DEMO BEAD OF SEALANT,
SCRAPE SURFACE CLEAN
DEMO EXISTING 24 GA. COATED
METAL CLEAT
5/8" PLYWOOD SHEATING
(EXISTING)
1/2" COVER BOARD (EXISTING)
DEMO EXISTING CEMENT
FIBER BOARD
EXISTING HAT CHANNEL TO
REMAIN
ROOFING MEMBRANE (EXISTING)
3" RIGID INSULATION (EXISTING)
T.O. FRAMING
121' - 2"
EXISTING PERSERVATIVE
TREATED WOOD NAILER;
PROTECT FROM DAMAGE
ADDED BLOCKING; ENSURE
NEW FLASHING IS PROUD OF
NEW METAL PANEL
CONTINUOUS BEAD OF NON-
CURING SEALANT
5/8" PLYWOOD SHEATING (EXISTING)
1/2" COVER BOARD (EXISTING)
METAL PANEL
EXISTING HAT CHANNEL TO
REMAIN
NEW ROOF MEMBRANE LAPPED
AND HEAT WELDED TO
EXISTING MEMBRANE IN
VERTICAL POSITION
ANCHOR BAR ATTACHED TO
BLOCKING USING #10 X 2"
STAINLESS STEEL
FASTENERS 12" O.C.
METAL PANEL CLIP
ANCHOR-TITE FASCIA COVER
UV RESISTANT FABRIC;
ATTACHED PER MFR; BLACK
SEAM PLATE - ANCHOR AT 12" O.C.
W/ APPROPRIATE FASTENERS
FOR WALL TYPE
ROOFING MEMBRANE (EXISTING)
SEALANT
SELF ADHERED FLASHING
MEMBRANE
PREFINSIHED METAL
FLASHING; FASTENED TO
PLYWOOD AND Z GIRT; 24"
O.C W/ SEALED FASTENERS
EXISTING HIGH TEMP MODIFIED
BITUMINOUS AIR BARRIER SHEET
MEMBRANE
EXISTING LOW PROFILE ELECTRIFIED
BIRD DETERENT FLEX TRACK
LAP SHEET AIR & WATER
BARRIER OVER FLUID APPLIED
BARRIER
DEMO CEMENT FIBER PANELS
EXISTING 7/8" HAT CHANNEL
EXISTING PREFINSIHED METAL
FLASHING
EXISTING HIGH TEMP MODIFIED
BITUMINOUS AIR BARRIER SHEET
MEMBRANE
EXISTING LOW PROFILE ELECTRIFIED
BIRD DETERENT FLEX TRACK
EXISTING INSULATION;
PROTECT FROM DAMAGE
NEW METAL PANELS
EXISTING 7/8" HAT CHANNEL
METAL PANEL TOP CLIP
FASTENED TO EXISTING
HAT CHANNEL
METAL PANEL CLIP
FASTENED TO EXISTING
HAT CHANNEL
UV RESISTANT FABRIC;
ATTACHED PER MFR; BLACK
EXISTING DOOR
SYSTEM & HEADER,
PROTECT IN PLACE
DEMO EXISTING
FACADE PANELS &
FABRIC
EXISTING DOOR
SYSTEM & HEADER,
PROTECT IN PLACE
METAL ENCLOSURE
FLASHING WITH
WEEP - MATCH DOOR
FRAME FINISH
METAL WALL PANELS
UV RESISTANT FABRIC;
ATTACHED PER MFR; BLACK
WEEP HOLE
METAL ENCLOSURE
FLASHING - MATCH
DOOR FRAME FINISH
METAL WALL PANELS
UV RESISTANT FABRIC;
ATTACHED PER MFR; BLACK
WEEP HOLE
DEMO EXISTING
FACADE PANELS &
FABRIC
LEVEL 01
100' - 0"
SLOPE
DEMO EXISTING FACADE PANELS
& FABRIC
EXISTING HAT CHANNELS TO
REMAIN PROTECT IN PLACE
EXISTING FOUNDATION
TO REMAIN PROTECT IN
PLACE
LEVEL 01
100' - 0"
SLOPE
EXISTING INSULATION;
PROTECT FROM DAMAGE
NEW METAL PANELS
EXISTING 7/8" HAT CHANNEL
METAL PANEL CLIP
FASTENED TO EXISTING
HAT CHANNEL
UV RESISTANT FABRIC;
ATTACHED PER MFR; BLACK
WEEP HOLE
PRE-FINISHED METAL FLASHING
WITH DRIP EDGE
NEW FACADE PANEL, RETURN
EXISTING WALL TO REMAIN, PROTECT
ALIGN
3/8"
METAL PANEL CLIP
FASTENED TO HAT CHANNEL
NEW FACADE PANEL,
RETURN TO NEXT SEAM
CONTRACTOR TO
COORDINATE IN SHOP
DRAWINGS.
METAL PANEL CLIP
FASTENED TO HAT
CHANNEL
3/8" TYPICAL JOINT
SPACING
NEW FACADE PANEL4" MIN, +/-
3" = 1'-0"A-501
A1 METAL PANEL PLAN CORNER DETAIL
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJECT #:
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
SMS
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© Architectural Nexus, Inc. 2021
654321
E
D
C
B
A
/1
/2
:4
:5
P M
SECTION
DETAILS
BF
D F
C M
P ro je c t
U T
A H
D E
P A
R T
M E
N T
O F
A L
C O
H O
L
IC
B E
V E
R A
G E
S E
R V
IC
E
S
26028
17 June 2026
F A
R M
IN
G
T O
N S
T O
R E
F A
C A
D E
R E
P L
A C
E M
E N
T
CONSTRUCTION
DRAWINGS
A-501
N o rt h L a g o o n D ri v e
F a rm in g to n
U ta h
3" = 1'-0"A-501
D6 SOFFIT DETAIL - DEMO
3" = 1'-0"A-501
D3 SOFFIT DETAIL - NEW
3" = 1'-0"A-501
E6 TYP. PARAPET DETAIL - DEMO
3" = 1'-0"A-501
E3 TYP. PARAPET DETAIL - NEW
3" = 1'-0"A-501
B6 ROOF/CEILING DETAIL @ CUBBY STORAGE - DEMO
3" = 1'-0"A-501
B3 ROOF/CEILING DETAIL @ CUBBY STORAGE - NEW
3" = 1'-0"A-501
D2 EXTERIOR SLIDING DOOR HEAD- DEMO
3" = 1'-0"A-501
D1 EXTERIOR SLIDING DOOR HEAD
3" = 1'-0"A-501
E1 EXTERIOR SLIDING DOOR JAMB
3" = 1'-0"A-501
E2 EXTERIOR SLIDING DOOR JAMB - DEMO
3" = 1'-0"A-501 A6
FIBER CEMENT PANEL FOUNDATION WALL DETAIL -
DEMO (TYP.)
3" = 1'-0"A-501
A3
METAL PANEL @ FOUNDATION WALL DETAIL - NEW
(TYP.)
3" = 1'-0"A-501
B1 METAL PANEL PLAN CORNER FOLDLINE DETAIL # Date Revision
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
| DABS FACADE REPLACEMENT PLANS |
| GENERAL |
| G-001 - COVER SHEET |
| G-002 - GENERAL INFORMATION |
| ARCHITECTURAL |
| A-101 - SITE & FLOOR PLAN |
| A-201 - ELEVATIONS - DEMO |
| A-202 - ELEVATIONS |
| A-203 - ENLARGED ELEVATIONS & DETAILS |
| A-501 - SECTION DETAILS |
File details come from the government source that posted it. Updated .