This document is a comprehensive traffic signal design plan set prepared by the Pennsylvania Department of Transportation (PennDOT) for intersection improvements at SR 0309 (Memorial Highway), SR 1036 (Carverton Road), and Church Road in Kingston Township, Luzerne County. The plan details a complex traffic signal system with multiple phases, emergency preemption capabilities, radar detection systems, and specific signal timing sequences for different times of day (AM, MD, PM, and Saturday cycles). The design includes detailed specifications for signal heads, signs, conduit, and cable requirements, with particular attention to emergency vehicle preemption for the Trucksville Volunteer Fire Company.

The technical drawings provide intricate details on signal phasing, timing charts, coordination diagrams, and emergency preemption protocols. The plan specifies LED signal indications, backplates with retroreflective borders, and specific signage for each approach, including illuminated "No Turn on Red" signs. The design incorporates radar detection zones with speed range capabilities from 35 to 100 MPH and detection ranges from 0-100 feet from stop bars. The controller assemblies are designed with multiple detection zones and fail-safe mechanisms, ensuring robust traffic management and safety features at this complex intersection. The documents are stamped with professional engineering approval and include revision dates indicating ongoing refinement of the original 1997 design.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C H

U R

R O

A D

10'

10'

PHASE 1+5 PHASE 1+6 PHASE 2+5 PHASE 2+6 PHASE 3+8

INTERVAL INTERVAL INTERVAL INTERVAL INTERVAL INTERVAL

SIGNALS

MEMORY

F L

A S

H I

N G

E M

E R

G E

N

Y

OFF

Y

R

R

7,8

9,10

11,12

13,14

1 1 1 1 12 2 2 2 23 3 3 3 3 14 4

G G

GG Y

G

RRR

RRR

R R R

RRR R

R

G Y

R

R R

R

R

Y

R

RR

R

GG

R

R RRRR

R

R

R

RRR

R

R

R

R R R R

R

R

RRR

R

R R

R

R

R

R

R

H

MAX I

PASSAGE

MINIMUM

FIXED 3.22.6 3.22.6 3.22.6 2.64.8 4.0

15 5

3 3 3 4

15 15 1550

MAX II

INTERVAL INTERVAL INTERVAL INTERVAL

1 1 1 12 2 2 23 3 3 3

R R

RR

DW DW

DW DW

DW DW

DW DW

DW DW

DW DW DW DW

Y R

RY

R

R

DW

DW

DW

DW

DW

DW

DW

DW DW DW

PHASE 6 PHASE 2 PHASE 4 PHASE 8

H H

H H H

H H H

H H H

R R R

1 1

R

R

R

RRR R

1 1

W FH H

H H H

H

H

W FH H

H H H

H

H

Y

R

R

R

R

R R

YG Y RG

W FH H H

H H H H

H

H H

H H

H

R

R

R

R

R

R

OFF

R

R

G

R

R

R

R

R R

RR

R R

RR

Y

Y

R

RG

R

R

R

RR

R R

RR

R

R

R

R

R

R

R

G

R

R R

RY

R R

RR

R

R

R

R

R

R

R

G

R

R

R R

R

60 5.04.0

5 5 5

10 10 10 39 10

7.2

7.2

7.2

6.2

7.2

7.2

8.2

7.2

8.0

34.6

74.6

29.6

4.8 4.8 5.0 5.0+ 2.6 + 2.6 + 4.0 + 4.0

PHASING, TIMING AND COLOR SEQUENCE CHART

Y

SR 0309 (MEMORIAL HWY) &

SR 1036 (CARVERTON RD) & CHURCH RD SR 0

(MEMORIAL HWY)

SR

MEMORI

AL

HWY)

C

A R

V E

R T

N

D

S R

* DAY 1 IS SUNDAY

WEEKLY PROGRAM CHART

EVENT WEEK

1 TO 52

1 TO 52

1 TO 52

* DAY HOUR DIAL NO. YIELD POINT

YIELD POINT REFERENCE TO START OF INTERVAL 3, PHASE 2+6

1 TO 52

1 TO 52

1 TO 52 2 TO 6

REMARKS

AM CYCLE (116 SEC)

FREE MAX1

MD CYCLE (85 SEC)

FREE MAX1

FREE MAX1

PM CYCLE (128 SEC)

2,3

5,6

COORDINATION DIAGRAM

RD.

CARVERTON

HILL

HARRIS

PIONEER/

DR

PENDRAGON

RADAR DETECTION SYSTEM NOTES

*** ADVANCE DILEMMA ZONE

*** DENSITY ZONE NOTES

MINIMUM SPEED BOUNDARY: 1 MPH - 40 MPH

RANGE OF DETECTION: 0-100 FT FROM STOP BAR

SPEED RANGE: 35 MPH - 100 MPH

RANGE OF PROTECTION: MIN. 0 - MAX. 500 FT.

EST. TIME OF ARRIVAL: MIN. 2.5 - MAX. 5.5 SEC

LEGAL RIGHT-OF-WAY LINE

L

EGAL

R

IG

HT-

OF

-W

AY

LIN

E

LE

GAL

RIG

HT-O

F-W

AY L

INE

PEDESTRIAN*

0 SEC

0 SEC

0 SEC

DIAL 2

DIAL 3

DIAL 4

NL mR

NL = NON-LOCKING

mR = MINIMUM RECALL

NL NL NL

5 5

+ FOR DURATION OF PREEMPTION.

a a a a a b a b a

G

G

G

G

NORMAL OPERATION

G/Y WHEN RETURNING TO

OPERATION

G WHEN RETURNING TO NORMAL

b

PHASE F **

PREEMPTION

FIREHOUSE EMERGENCY PREEMPTION

S

E

L

E

C

T

I

V

E

L

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

THE SIGNAL IS PERMITTED.

MAINTAIN THE TRAFFIC SIGNAL INTERCONNECT AFTER

INTERCONNECT IS FUNCTIONAL. THE PERMITTEE IS TO

16.THE CONTRACTOR IS TO ENSURE THE TRAFFIC SIGNAL

TO RED, YELLOW, GREEN OPERATION.

15.SIGNALS MUST FLASH A MINIMUM OF THREE DAYS PRIOR

WITNESS THE TESTING.

(PUB 408), SO THAT DISTRICT REPRESENTATIVES MAY

FUNCTIONAL SHOP TEST AS REQUIRED IN SECTION 1104

CALENDAR DAYS PRIOR TO CONDUCTING A PHYSICAL AND

14.NOTIFY THE DISTRICT TRAFFIC ENGINEER SEVEN

YELLOW, GREEN OPERATION.

DAYS PRIOR TO PLACING THE SIGNALS INTO RED,

TRAFFIC SIGNAL INSPECTION A MINIMUM OF THREE

13.CONTACT PENNDOT TRAFFIC UNIT TO SCHEDULE A

PUT INTO RED, YELLOW, GREEN OPERATION.

INDICATED ON THIS PLAN, BEFORE SIGNALS CAN BE

12.INSTALL ALL SIGNS AND PAVEMENT MARKINGS, AS

SURROUNDING GRADE.

FOUNDATIONS FLUSH WITH THE SIDEWALK OR

CURB. INSTALL MAST ARMS AND PEDESTAL POLE

HEADS A MINIMUM OF 2 FEET BEHIND THE FACE OF

11.INSTALL SIGNAL SUPPORTS AND POST MOUNTED SIGNAL

HEADS AS VIEWED FROM THE APPROACH.

MAINTAIN A MINIMUM OF 8 FEET SEPARATION BETWEEN

THE ROADWAY. ALL TRAFFIC SIGNAL HEADS ARE TO

LESS THAN 15 FEET NOR MORE THAN 19 FEET ABOVE

10.INSTALL SIGNAL HEADS AND SIGNS WITH BOTTOMS NOT

DETECTION.

AND ALSO THE PROPER USE OF CAMERAS FOR VEHICLE

INTERFERE WITH CLEAR VISION OF THE SIGNAL HEADS

RELOCATION OF OVERHEAD UTILITIES THAT MAY

THE PERMITTEE IS RESPONSIBLE FOR MAINTAINING ANY 9.

COMPANIES TO RESOLVE ANY CONFLICTS.

PRIOR TO CONSTRUCTION, CONSULT WITH UTILITY

PREVENTION OF DAMAGE TO UNDERGROUND UTILITIES.

PROVISIONS OF ACT 287 OF 1974 AS AMENDED,

DRAWING, UNLESS THE PERMITTEE COMPLIES WITH THE

THIS DRAWING CANNOT BE USED AS A CONSTRUCTION 8.

CARD RACK TO BE NEMA TYPE 7-T.7.

AND DELAYS TO ALL INDIVIDUAL ZONES.

WHICH WILL PROVIDE THE CAPABILITY OF EXTENSIONS

SEPARATE DETECTOR INPUT IN THE CONTROLLER TIMER

EACH DETECTION ZONE MUST BE ASSIGNED TO A 6.

HIGHWAYS.

MAINTAINS THE LONGITUDINAL MARKINGS ON STATE

MAINTAINED BY THE PERMITEE. THE DEPARTMENT

PERMIT ARE TO BE HOT THERMOPLASTIC AND

ALL PAVEMENT MARKINGS ON THE TRAFFIC SIGNAL 5.

INDICATED.

CONSIDERED PART OF THE PERMIT, UNLESS OTHERWISE

BLOCK INDICATED ON THIS DRAWING, WHICH ARE

THE PERMITTEE MAINTAINS ALL SIGNS IN THE SIGN 4.

PERMITTEE.

OF TREES, IS THE RESPONSIBILITY OF THE

VISIBILITY OF THESE SIGNALS, INCLUDING TRIMMING

ALL MAINTENANCE NECESSARY FOR THE PROPER 3.

WRITING, BY THE DISTRICT TRAFFIC ENGINEER.

PERMITTED UNLESS PRIOR APPROVAL IS GRANTED, IN

NO MODIFICATION OF THIS INSTALLATION IS 2.

SIGNAL DESIGN HANDBOOK (PUB 149).

STANDARDS (TC-8700 AND TC-8800), AND TRAFFIC

SPECIFICATIONS (PUB 408), TRAFFIC CONTROL

OFFICIAL TRAFFIC CONTROL DEVICES (PUB 212),

DEPARTMENT OF TRANSPORTATION REGULATIONS ON

SIGNAL IN ACCORDANCE WITH PENNSYLVANIA

INSTALL, OPERATE AND MAINTAIN THIS TRAFFIC 1.

3338 2 3

3-17-1997

LEGEND

RR R R R R R RRR R RRRR Y R

PHASE 4+8

INTERVAL

1 2 3 4

R

R

R

R R R R

R

R

RRR

R

R R

R

5.04.0

G

G Y

Y R

R

G

G

W FH H H

H H H H

7.0

7.0

NL

Y RFYFY15

6.2 8.0

G G

6.2 6.2 6.2 53.6DIAL 1 8.0

Y R

Y R R R R

R R R R Y RFYFYG

G

Y RG

Y RGG Y RFYFY

OTHERWISE DON'T WALK AT ALL TIMES.

UPON PEDESTRIAN ACTUATION ONLY, *

UPON FIREHOUSE PREEMPTION ONLY**

SIGN R

R

R

OFFOFFOFF ON ON ONOFF OFFOFFOFF OFF OFF OFFOFFOFF OFFOFFOFF

R RRR

3.0

2 TO 6

7 1 TO 52 1,7 1030

2 TO 6

2 TO 6

1 TO 7

2 TO 6

SAT CYCLE (80 SEC)4 0 SEC

7.0

7.0

19.0

5 5

OR BE COMPLETED IN FOLLOWING PHASE.

PHASE. IT MAY TIME OUT IN THIS PHASE

TIMING WILL BE AS SHOWN IN FOLLOWING 5.

4. <-FY- IF FOLLOWED BY 2+5

3. <-FY- IF FOLLOWED BY 1+6

2. G IF FOLLOWED BY 4+8

1. G IF FOLLOWED BY 2+6

S T

A T

F

P E

N N S

Y L

V A

N I

A

R P

O R

A T I

T

S S

O C I

A T I

O

D A R

C R E S T

C E

M E T E

B U R

K H

A R

D T

P A

U

VEHICULAR SIGNAL HEAD

PEDESTRIAN PUSH BUTTON

PEDESTRIAN SIGNAL HEAD

JUNCTION BOX

CONTROLLER ASSEMBLY

CONDUIT / WIDTH

SOLID WHITE LINE/WIDTH

SOLID YELLOW LINE/WIDTH

BROKEN WHITE LINE/WIDTH

POLE/MAST ARM / LENGTH

RADAR DETECTOR

RADAR DETECTION AREA

EMERGENCY PREEMPTION BEACON

EMERGENCY PREEMPTION DETECTOR

SPREAD SPECTRUM ANTENNA

OVERHEAD SIGN

POST MOUNTED SIGN

BROKEN WHITE EXTENSION LINE/WIDTH

G

B N

E

M

K

G

L

R

D

O E

D

C

11 10

D

C/2"

C/3"

C/3"

C/3"

CC4CC2

R1

R2

B1 D1

B2

R3

R4

B3

D3

CC3

R2

R1

R3

R3

R4

C/1"

C/1"

2-C/4"

20'

D1

B1

A

P4

W/4"

Y/4"

BW/4"

C/4"

R1

R1

CC-2

A

BWE/4"

R5

R6

K

G

CC-2

D4

MPH

-4

GRADE

C/ 3"

MPH+5

GRADE

PI

ONEER

AVE.

NEAREST

SI

GNAL

A

Q

F

F

P

I

H

J

H

0'

@ HILLSIDE R

D.

NEAREST S

IGNAL

D2

C/4"

C/2"

W I T

H I

M

L E

N O

S I

G N

P

H

G

A D E

W I

T H I

L E

G N

H

A D

E

STOP BAR

500'IN ADVANCE OF

STOP BAR

ADVANCE OF

500'IN

B B4

E

E

10 12

C/ 2"

C/ 4"

C

C/1"

C

2-C/1"

C/ 1"

C/ 1"

89 C/1" C/1"

C/ 2"

C/ 1"

C/ 2"

C/1"

2-C/1"

C/1"

VOLUNTEER FIRE CO.

TO TRUCKSVILLE

PREEMPTION WIRE

2-C/1"

C/1"

C/2"

2-C/1"

(MASTER)

PERMIT NO. SHEET OF

DATE ISSUED DATE REVISED

DISTRICT COUNTY ROUTE SECTION SHEET

4-0 LUZERNE

DISTRICT TRAFFIC ENGINEER DATE

MUNICIPAL OFFICIAL DATE

COUNTY:

MUNICIPALITY:

INTERSECTION:

REVIEWED:

RECOMMENDED:

SCALE:

LUZERNE COUNTY

25 50 75

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T

W i g n a l o r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

C a r v e r t n d

A d g n

PROFESSIONAL

REGISTERED

F O

H

TL

AEWN

O

M M

O C

A I

N A

VLYS

N

N

E P

ENGINEER

WENDY C. KELLEY

No. PE075354

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

C a r v e r t

A d g n

KINGSTON TOWNSHIP

KINGSTON TOWNSHIP

GENERAL NOTES

W/ 4"

W/ 6"

W/ 6"

W/ 6"

Y/ 4"

Y/ 4"

W

W

W/ 6"

W/ 4"

W/ 6"

BW/

6"

W/ 4"

Y/ 4"

Y/ 4"

W

D Y "W

D Y

BW/

6"

BW/6"

BW/6"

W/4

Y/4

Y/4

BWE/6"

BW/

6"

W

W

T Y

P

B W

E

BW/6"

B W

B W

W

W

W

SR 0309 (MEMORIAL HWY) &

SR 1036 (CARVERTON RD) & CHURCH RD

AA

A

A A

A

A

A

A

A

A

A

A

AA

6" LOWER CASE

8" UPPER CASE

0.8" BORDER WITH 2.5" CORNER RADII

BACKGROUND GREEN (REFLECTORIZED)

LEGEND AND BORDER WHITE (REFLECTORIZED)

LEGEND COMPRESSED 20%

CLEARVIEW 3W

6" LOWER CASE

8" UPPER CASE

0.8" BORDER WITH 2.5" CORNER RADII

BACKGROUND GREEN (REFLECTORIZED)

LEGEND AND BORDER WHITE (REFLECTORIZED)

LEGEND COMPRESSED 20%

CLEARVIEW 3W

R

N.T.S.

(FOR INFORMATION ONLY)

ILLUMINATED SIGN

ON RED

NO

TURN

NEMA PHASING DIAGRAM

EMERGENCY PREEMPTION NOTES

1+6

4+8

2+6

1+5

2+5

PHASING DIAGRAM

VEHICLE PREEMPTION

EMERGENCY / FIREHOUSE

PREEMPTION

FIREHOUSE

EMERGENCY /

OPERATION.

ESTABLISHED. PREEMPTION SHALL BE A "FIRST COME, FIRST SERVE"

IN EMERGENCY OR FIREHOUSE PREEMPTION, NO PRIORITY SHALL BE

FOLLOW.

RETURNING TO NORMAL OPERATION, PHASE 2+6 INTERVAL 1 SHALL

UPON COMPLETION OF THE PREEMPTION PHASE 2, 4, 6, 8 OR "F" IN

PROCEEDING TO THE NEXT PREEMPTION PHASE.

PREEMPTION, THE ORIGINAL PREEMPTION PHASE SHALL TIME OUT BEFORE

IF ADDITIONAL PREEMPTION PHASES ARE ACTIVATED WHILE IN

VEHICLE ARE FLASHING, ALL SIGNALS SHALL REMAIN FLASHING.

IF THE SIGNALS WHEN ACTIVATED BY AN EMERGENCY OR FIREHOUSE

BEFORE GOING INTO EMERGENCY OR FIREHOUSE PREEMPTION.

SHALL TIME OUT FOLLOWED BY THE APPROPRIATE SELECTIVE CLEARANCES

IMMEDIATELY, FOLLOWED BY THE PED CLEAR INTERVAL. THIS INTERVAL

THE SIGNAL IS PREEMPTED, THE PED WALK INTERVAL SHALL TERMINATE

IF SIGNALS HAVE BEEN ACTUATED BY PEDESTRIAN PUSH BUTTON, AND

INDICATIONS DISPLAYED FOR ALL OTHER PHASES.

"GREEN" FOR THE DURATION OF SIGNAL PREEMPTION AND "RED"

"GREEN" INDICATIONS FOR THE PREEMPTED PHASE SHALL REMAIN

DEPENDENT UPON THE PHASE IN WHICH THE PREEMPTION OCCURS. THE

OR FIREHOUSE VEHICLE, FOLLOWED BY SELECTIVE CLEARANCES

INDICATIONS FOR THE PHASE GOVERNED BY THE APPROACHING EMERGENCY

VEHICLE, SHALL TERMINATE ALL GREEN INDICATIONS EXCEPT THE GREEN

THE SIGNAL, WHEN ACTIVATED BY AN EMERGENCY OR FIREHOUSE

ADJUSTED TO ACHEIVE MAXIMUM OPERATION.

LOCATION OF THE EMERGENCY VEHICLE DETECTORS ARE TO BE FIELD

THE INTERSECTION FOR THE APPROPRIATE APPROACH.

LIGHT AND SHALL FLASH WHEN THE EMERGENCY VEHICLE HAS CONTROL OF

THE EMERGENCY BEACON SHALL CONSIST OF A FLASHING WHITE FLOOD

RD. WITH A FAIL SAFE DEVICE FOR EACH DIRECTION OF OPERATION.

APPROACH OF CHURCH RD., AND THE WESTBOUND APPROACH OF CARVERTON

NORTHBOUND & SOUTHBOUND APPROACHES OF S.R. 0309, THE EASTBOUND

CONTROLLER TO BE EQUIPPED WITH EMERGENCY PREEMPTION FOR THE

3 3

3-17-1997

R

G

Y

12"

SIGNALSSIGNALS

HOUSING

ONE PIECE

SIGNAL INDICATIONS

ALL SIGNALS EQUIPPED WITH LEDS

VISORS

SIGNALS 7 & 8 EQUIPPED WITH TUNNEL

WITH 2" RETROREFLECTIVE BORDERS

SIGNALS 1-10 EQUIPPED WITH BACKPLATES

R

G

Y

12"

FY

R10-6L

R10-11

R10-12

R3-5L

30x36

D3-4

D3-5

D3-5

R3-5R

R9-3

W3-3

R3-5S

R9-3-1R

R9-3-1L

R3-8L-SR

R3-8LTTR

NO TURN ON RED

NO PEDESTRIAN CROSSING

SIGNAL AHEAD

LEFT TURN YIELD ON GREEN

STRAIGHT THROUGH SIGN

LEFT TURN SIGN

RIGHT TURN SIGN

USE CROSSWALK, RIGHT

USE CROSSWALK, LEFT

LANE USE CONTROL SIGN

LANE USE CONTROL SIGN

24x30

30x36

9x15

18X18

36x36

30x36

30x36

96x16

96x28

96x28

18x12

18x12

30x30

30x48

SIGN TABULATION

SERIES QTY.DESCRIPTIONSYMBOL SIZE

R10-3EL

9x15R10-3ER

STOP HERE ON RED

SIGNAL W/ COUNTDOWN TIMER <--

EDUC. PUSH BUTTON FOR WALK

SIGNAL W/ COUNTDOWN TIMER-->

EDUC. PUSH BUTTON FOR WALK

30x36NO TURN ON RED (ILLUMINATED)*R10-11

Memorial Hwy

30x36R10-12A LEFT TURN YIELD ON FLASHING YELLOW ARROW

1 2

65 8

24 31 13 145 6

G

M

D

C

1L

N

O

1R

K 2

9 1087

11 12

A

F

I

J

Q

P

H

E 2

B 1

SIGNALS

CONTROLLER ASSEMBLY CC2

14 2

2 133

3 2 1

5 16 1

10 2 2 1

7 2 1

2 1

3312 2 1

12321

R1

R2

R3

R4

R5

R6

1 1

1 1

3 321

3 321

44321

1 2

1 2

D3

B3

B4

D1

B1

D2

B2

1 1

1 1

3 521

3 321

2 2 1

4 4 3 2 1

7C/14

5C/14

5C/14

5C/14

5C/14

5C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

15 2 2 1 7C/14

1 3 2 13

4 1 1

7C/14

5C/14

5C/14

5C/14

3 321 3C/14

R

- DETECTOR

- SIGNAL HEAD

5C/14 - CABLE (NO. OF CONDUCTORS/SIZE AWG)

- JUNCTION BOX

- TRAFFIC SIGNAL SUPPORT

- DETECTOR

- SIGNAL HEAD 3

* SIZE CABLE AS RECOMMENDED BY MANUFACTURER

54 76 3C/14

33 2 1

11D4

WIRING DIAGRAM

RED ILLUMINATION

BALL - "BLANK-OUT" LED

- BLACK

SIGN FACE AND FRAME

6" LETTER HEIGHT

WHITE ILLUMINATION

LETTERS - "BLANK-OUT" LED

Memorial Hwy

6" LOWER CASE

8" UPPER CASE

0.8" BORDER WITH 2.5" CORNER RADII

BACKGROUND GREEN (REFLECTORIZED)

LEGEND AND BORDER WHITE (REFLECTORIZED)

CLEARVIEW 3W

3"

5"

96"

8"

96"

5"

3"

8"

8"

TOTAL - 96"

SPACE - 7.7"

y - 5.5" w - 9.6"

H - 7.3"

SPACE - 6.00"

l - 2.2" a - 7.4" i - 3.6" r - 5.0" o - 7.7" m - 10.3" e - 7.4"

M - 8.6"

SPACE - 7.7"

Church Rd -->

<-- Carverton Rd

Carverton Rd -->

<-- Church Rd

Church Rd

Carverton Rd

96"

5"

3"

8"

8"Carverton Rd

Church Rd

TOTAL - 96"

SPACE - 5.2"

- 9.0"

SPACE - 6.0"

d - 5.2"

R - 6.6"

SPACE - 6.0"

n - 5.0" o - 7.3" t - 4.8" r - 4.2" e - 6.9" v - 6.5" r - 4.2" a - 7.0"

C - 6.8"

SPACE - 5.3"

TOTAL - 96"

SPACE - 19.0"

d - 5.2"

R - 7.0"

SPACE - 6.0"

h - 5.0" c - 6.6" r - 4.8" u - 7.3" h - 7.4"

C - 7.4"

SPACE - 6.0"

- 9.0"

SPACE - 5.3"

TOTAL - 96"

SPACE - 5.2"

d - 5.2"

R - 6.6"

SPACE - 6.0"

n - 5.0" o - 7.3" t - 4.8" r - 4.2" e - 6.9" v - 6.5" r - 4.2" a - 7.0"

C - 6.8"

SPACE - 6.0"

- 9.0"

SPACE - 5.3"

TOTAL - 96"

SPACE - 19.0"

- 9.0"

SPACE - 6.0"

d - 5.2"

R - 7.0"

SPACE - 6.0"

h - 5.0" c - 6.6" r - 4.8" u - 7.3" h - 7.4"

C - 7.4"

SPACE - 5.3"

PERMIT NO. SHEET OF

DATE ISSUED DATE REVISED

DISTRICT COUNTY ROUTE SECTION SHEET

4-0 LUZERNE

DISTRICT TRAFFIC ENGINEER DATE

MUNICIPAL OFFICIAL DATE

COUNTY:

MUNICIPALITY:

INTERSECTION:

REVIEWED:

RECOMMENDED:

SCALE:

LUZERNE COUNTY

25 50 75

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

C a r v e r t

A d g n

PROFESSIONAL

REGISTERED

F O

H

TL

AEWN

O

M M

O C

A I

N A

VLYS

N

N

E P

ENGINEER

WENDY C. KELLEY

No. PE075354

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

C a r v e r t

A d g n

KINGSTON TOWNSHIP

KINGSTON TOWNSHIP

K

PL

RIGHT-OF-WAY LINE

LEGAL

M A

T

N E

HAZARD MARKER18X18W16-1D

YIELD TO PEDESTRIANS

DO NOT ENTERR5-1

R1-5

9X15

24X18

30X30

SIGN SIZE

24X24

RIGHT ONE WAY SIGN

LEFT ONE WAY SIGN

STOP

36X12

36X12

30X30R1-1

R6-1L

R6-1R

R10-12

R3-1 30X30

30X36

NO RIGHT TURN

LEFT TURN YIELD ON GREEN

R3-1 NO RIGHT TURN

W11-2 30X30

D3-5 84X28

84X28D3-5

D3-4 96X16

<-- Pioneer

Harris Hill -->

<-- Harris Hill

Pioneer -->

R3-7L 30X30 LEFT LANE MUST TURN LEFT

9X15

R9-3-1L 18X12 USE CROSSWALK, LEFT

R9-3-1R 18X12 USE CROSSWALK, RIGHT

SR 0309 (MEMORIAL HWY)

& PIONEER AVE / HARRIS HILL RD

SERIES QTY. DESCRIPTION

SR 0309 (MEMORIAL HWY)

45 MPH

+1.2% GRADE

SR 0309

(MEMORIAL HWY)

45 MPH

PIONEER AVE.

H A

R R

A D

H

EMERGENCY PREEMPTION

MASTARM 2

DETAIL

PHASING, TIMING AND COLOR SEQUENCE CHART SIGN TABULATION

R10-3ER

R10-3EL

MASTARM 3

DETAIL

M A

T

N E

R

GG

Y Y

R

G

Y

12" 12"

SIGNALSSIGNALS

HOUSING

ONE PIECE

SIGNALS

SIGNAL INDICATIONS

560' @ SHEETZ DR.

NEXT SIGNAL

1160'

@ CARVERTON RD

NEXT SIGNAL

O F F

O F F

11 21

C Y

C

N G

T H

DIAL 3 (PM)

DIAL 2 (MD)

DIAL 1 (AM)

DWDWDWDW

DWDWFD*W*DWDWDWDWDWDWDW

DWDWDW

DWDWDWDW

DWDWFD*W*DWDWFD*W*

DWDWDW

DWDWDW

13,14

R

R

R

R

G

G

G

G

G

R

R

G G

R

G

R

G G

G

R

R

R

4 4 44

FIXED

PHASE

INTERVAL

SIGNAL

R

R

R R

RR

R

R

R R R

R

R

R

R

R

R

Y

Y

R

Y

1 12

1+5 1+6

MINIMUM 5

PASSAGE 3

MAX I 12

MAX II 12

PEDESTRIAN -

MEMORY

3 3

4+8

R

R

R

R

R

R

R

G

R R

RY

R R R YGR RR

G Y R

R R

2+5

RR

RR

G

2+6

G

G

G

R RR

G G

YG

R R

R

Y R

Y R

RY

RY

Y R

Y R

Y R

Y R

DW

DWDWDW

DW DW

DW

DWDWDW

DW

DWDW DW

DWDWDW

DWDWDW

DWDW DW

R R

RR

R

R

R R R

1 2 3 321

R

R

R

R

R

R

R

G

R

R

RY

R R RG R R R

RRR

G

R RR

R RR

G G

G G

Y R

Y R

RY

RY

R

R

R

R

PHASE 6 PHASE 2 PHASE 4 PHASE 8

DW

RR

R R

RR

7,8

9,10

GRRR R RRR R R RG RYRR R RR R RR G RYR RR R

R R R R

SIGNAL W/ COUNTDOWN TIMER-->

EDUC. PUSH BUTTON FOR WALK

SIGNAL W/ COUNTDOWN TIMER <--

EDUC. PUSH BUTTON FOR WALK

RADAR DETECTION SYSTEM NOTES

*** ADVANCE DILEMMA ZONE

*** DENSITY ZONE NOTES

MINIMUM SPEED BOUNDARY: 1 MPH - 40 MPH

RANGE OF DETECTION: 0-100 FT FROM STOP BAR

SPEED RANGE: 35 MPH - 100 MPH

RANGE OF PROTECTION: MIN. 0 - MAX. 500 FT.

EST. TIME OF ARRIVAL: MIN. 2.5 - MAX. 5.5 SEC

LEGAL RIGHT-OF-WAY LINE

LE

GAL R

IGHT-OF

-WAY LI

NE

OTHERWISE DON'T WALK AT ALL TIMES.

UPON PEDESTRIAN ACTUATION ONLY, *

PEDESTRIAN CROSSING

NL mR

NL = NON-LOCKING

mR = MINIMUM RECALL

NL NL NL

2,3

5,6

E M

E R

G

A S

H

11,12

+ FOR DURATION OF PREEMPTION.

a

NORMAL OPERATION

G/Y WHEN RETURNING TO

OPERATION

G WHEN RETURNING TO NORMAL

b b b a aa a aa

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

S

E

L

E

C

T

I

E

A

R

A

N

C

E

S

LEGEND

O F

FDWDWDWDWDWDWDW DWDWFD*W*DWDW FD*W*DWDWDW15,16

36X36

30X18

W11-2

W16-7P

PEDESTRIAN

THE SIGNAL IS PERMITTED.

MAINTAIN THE TRAFFIC SIGNAL INTERCONNECT AFTER

INTERCONNECT IS FUNCTIONAL. THE PERMITTEE IS TO

16.THE CONTRACTOR IS TO ENSURE THE TRAFFIC SIGNAL

TO RED, YELLOW, GREEN OPERATION.

15.SIGNALS MUST FLASH A MINIMUM OF THREE DAYS PRIOR

WITNESS THE TESTING.

(PUB 408), SO THAT DISTRICT REPRESENTATIVES MAY

FUNCTIONAL SHOP TEST AS REQUIRED IN SECTION 1104

CALENDAR DAYS PRIOR TO CONDUCTING A PHYSICAL AND

14.NOTIFY THE DISTRICT TRAFFIC ENGINEER SEVEN

YELLOW, GREEN OPERATION.

DAYS PRIOR TO PLACING THE SIGNALS INTO RED,

TRAFFIC SIGNAL INSPECTION A MINIMUM OF THREE

13.CONTACT PENNDOT TRAFFIC UNIT TO SCHEDULE A

PUT INTO RED, YELLOW, GREEN OPERATION.

INDICATED ON THIS PLAN, BEFORE SIGNALS CAN BE

12.INSTALL ALL SIGNS AND PAVEMENT MARKINGS, AS

SURROUNDING GRADE.

FOUNDATIONS FLUSH WITH THE SIDEWALK OR

CURB. INSTALL MAST ARMS AND PEDESTAL POLE

HEADS A MINIMUM OF 2 FEET BEHIND THE FACE OF

11.INSTALL SIGNAL SUPPORTS AND POST MOUNTED SIGNAL

HEADS AS VIEWED FROM THE APPROACH.

MAINTAIN A MINIMUM OF 8 FEET SEPARATION BETWEEN

THE ROADWAY. ALL TRAFFIC SIGNAL HEADS ARE TO

LESS THAN 15 FEET NOR MORE THAN 19 FEET ABOVE

10.INSTALL SIGNAL HEADS AND SIGNS WITH BOTTOMS NOT

DETECTION.

AND ALSO THE PROPER USE OF CAMERAS FOR VEHICLE

INTERFERE WITH CLEAR VISION OF THE SIGNAL HEADS

RELOCATION OF OVERHEAD UTILITIES THAT MAY

THE PERMITTEE IS RESPONSIBLE FOR MAINTAINING ANY 9.

COMPANIES TO RESOLVE ANY CONFLICTS.

PRIOR TO CONSTRUCTION, CONSULT WITH UTILITY

PREVENTION OF DAMAGE TO UNDERGROUND UTILITIES.

PROVISIONS OF ACT 287 OF 1974 AS AMENDED,

DRAWING, UNLESS THE PERMITTEE COMPLIES WITH THE

THIS DRAWING CANNOT BE USED AS A CONSTRUCTION 8.

CARD RACK TO BE NEMA TYPE 7-T.7.

AND DELAYS TO ALL INDIVIDUAL ZONES.

WHICH WILL PROVIDE THE CAPABILITY OF EXTENSIONS

SEPARATE DETECTOR INPUT IN THE CONTROLLER TIMER

EACH DETECTION ZONE MUST BE ASSIGNED TO A 6.

HIGHWAYS.

MAINTAINS THE LONGITUDINAL MARKINGS ON STATE

MAINTAINED BY THE PERMITEE. THE DEPARTMENT

PERMIT ARE TO BE HOT THERMOPLASTIC AND

ALL PAVEMENT MARKINGS ON THE TRAFFIC SIGNAL 5.

INDICATED.

CONSIDERED PART OF THE PERMIT, UNLESS OTHERWISE

BLOCK INDICATED ON THIS DRAWING, WHICH ARE

THE PERMITTEE MAINTAINS ALL SIGNS IN THE SIGN 4.

PERMITTEE.

OF TREES, IS THE RESPONSIBILITY OF THE

VISIBILITY OF THESE SIGNALS, INCLUDING TRIMMING

ALL MAINTENANCE NECESSARY FOR THE PROPER 3.

WRITING, BY THE DISTRICT TRAFFIC ENGINEER.

PERMITTED UNLESS PRIOR APPROVAL IS GRANTED, IN

NO MODIFICATION OF THIS INSTALLATION IS 2.

SIGNAL DESIGN HANDBOOK (PUB 149).

STANDARDS (TC-8700 AND TC-8800), AND TRAFFIC

SPECIFICATIONS (PUB 408), TRAFFIC CONTROL

OFFICIAL TRAFFIC CONTROL DEVICES (PUB 212),

DEPARTMENT OF TRANSPORTATION REGULATIONS ON

SIGNAL IN ACCORDANCE WITH PENNSYLVANIA

INSTALL, OPERATE AND MAINTAIN THIS TRAFFIC 1.

ALL SIGNALS EQUIPPED WITH LEDS

11-13-1947

1449 2 3

WITH 2" RETROREFLECTIVE BORDERS

SIGNALS 1-10 EQUIPPED WITH BACKPLATES

25 MPH

R

G G

R

G

R

R

DW

DW

DW

DIAGONAL DOWNWARD POINT ARROW

Memorial Hwy

COORDINATION DIAGRAM

RD.

CARVERTON

HILL

HARRIS

PIONEER/

DR

PENDRAGON

* DAY 1 IS SUNDAY

WEEKLY PROGRAM CHART

EVENT WEEK

1 TO 52

1 TO 52

1 TO 52

* DAY HOUR DIAL NO. YIELD POINT

YIELD POINT REFERENCE TO START OF INTERVAL 3, PHASE 2+6

1 TO 52

1 TO 52

1 TO 52 2 TO 6

REMARKS

AM CYCLE (116 SEC)

FREE MAX1

MD CYCLE (85 SEC)

FREE MAX1

FREE MAX1

PM CYCLE (64 SEC)

76 SEC

47 SEC

2 TO 6

7 1 TO 52 1,7 1030

2 TO 6

2 TO 6

1 TO 7

2 TO 6

SAT CYCLE (80 SEC)4 54 SEC

DIAL 4 (SAT)

2.03.02.8 3.02.8 3.02.8 3.33.5 3.33.5 3.3 3.52.0 2.0

7.2

7.2

7.2

7.2

7.2

7.2

7.2

7.27.2

7.2

7.2

7.2

69.8

30.8

45.8

50.8 8.2

8.2

20.2

7.2

113 SEC

5 5 5 5

PHASE 2+6.

THIS PHASE OR BE COMPLETED IN

PHASE 2+6. IT MAY TIME OUT IN

5. TIMING WILL BE AS SHOWN IN

4. G IF FOLLOWED BY 2+6

3. G/<-Y- IF FOLLOWED BY 2+6

2. R/<-G- IF FOLLOWED BY 2+5

1. R/<-G- IF FOLLOWED BY 1+6

10'

I S

A A

C S

H O

W A

R D

VEHICULAR SIGNAL HEAD

PEDESTRIAN PUSH BUTTON

PEDESTRIAN SIGNAL HEAD

JUNCTION BOX

CONTROLLER ASSEMBLY

CONDUIT / WIDTH

SOLID WHITE LINE/WIDTH

SOLID YELLOW LINE/WIDTH

BROKEN WHITE LINE/WIDTH

POLE/MAST ARM / LENGTH

RADAR DETECTOR

RADAR DETECTION AREA

EMERGENCY PREEMPTION BEACON

EMERGENCY PREEMPTION DETECTOR

SPREAD SPECTRUM ANTENNA

OVERHEAD SIGN

POST MOUNTED SIGN

BROKEN WHITE EXTENSION LINE/WIDTH

CC3

B

H

H

Q

C

C

D

H

H 3

3A

D

C 2

O 1

1P

Q 2

S 1

1 4 2 3 5

6 7 8

9 10

B1

D4 D2

D1

C/2"

B Q

R D 8

D3

B2

C

A

O

B4

30'

C/1"

A

B

B

P

S

R 1

R1

R2

R3

R4

30'

C/2"

R2

R1

R4

R

C/2"

A

T U

T U

U 4

T 4

T

U

T

U

20'

D1

B1

A

P4

W/4"

Y/4"

BW/4"

C/4"

R1

R1

CC-2

A

BWE/4"

R5

R6

CC4CC2 CC3

Q D

B2

B 9 R 11

D3

R2 R6

C

B4

O

10A

B 13

C/2"

C/1"

B3

C/1"

C/2"

C/3"

2- C/

4"

M

M

E

J

J

J

F

L

K

F K

L

28'

C

L

M

E

F

E 2

G

3L

K

J

N 1

M 3

C/1" 9 C/2"

C/2"

C/2"

C/2"

C/1"

C/1" 2-C/1"

C/2"

2-C/1"

2-C/1"

2-C/1"

C/1"

C/1"

C/1"

C/1"

6-07-2002

6-30-2021 EQUIPMENT UPGRADES WCK

WITHIN 1

MILE

NO S

IGNAL

W I

T H I

L E

G N

+5% GRADE

-2% GRADE

A D

E

4.24.24.2

1 1

2 2

(MASTER)

PERMIT NO. SHEET OF

DATE ISSUED DATE REVISED

DISTRICT COUNTY ROUTE SECTION SHEET

4-0 LUZERNE

DISTRICT TRAFFIC ENGINEER DATE

MUNICIPAL OFFICIAL DATE

COUNTY:

MUNICIPALITY:

INTERSECTION:

REVIEWED:

RECOMMENDED:

SCALE:

LUZERNE COUNTY

25 50 75

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

P i o n e e r v e d g n

PROFESSIONAL

REGISTERED

F O

H

TL

AEWN

O

M M

O C

A I

N A

VLYS

N

N

E P

ENGINEER

WENDY C. KELLEY

No. PE075354

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

P i o n e e d g n

KINGSTON TOWNSHIP

KINGSTON TOWNSHIP

GENERAL NOTES

BW/6"

W/4"

Y/6"

Y/6"

W/6"

BW/6"

W/6"

BW/4"

W/4"

Y

W

W/4"

W/4

Y/6"

BW/6"

W/4"

W/6"

W/4"

W/6"

Y/6"

D Y

W

W

DY/

4"

W/ 4"

W/4"

Y

W/24"

BW/4"

W/6"

W

T Y

P

BW/

6"

BW/6"

W

W/24"

MAC

SR 0309 (MEMORIAL HWY)

& PIONEER AVE / HARRIS HILL RD

M A

T

N E

SR 0309 (MEMORIAL HWY)

LEGAL RIGHT-OF-WAY LINE

LEGAL RIGHT-OF-WAY LINE

560' @ SHEETZ DR.

NEXT SIGNAL

1+6

4+8

2+6

1+5

2+5

PREEMPTION

EMERGENCY

DIAGRAM

PREEMPTION PHASING

EMERGENCY VEHICLE

EMERGENCY PREEMPTION NOTES

NEMA PHASING DIAGRAM

PREEMPTION SHALL BE A "FIRST COME, FIRST SERVE" OPERATION.

IN EMERGENCY PREEMPTION, NO PRIORITY SHALL BE ESTABLISHED.

FOLLOW.

RETURNING TO NORMAL OPERATION, PHASE 2+6 INTERVAL 1 SHALL

UPON COMPLETION OF THE PREEMPTION PHASE 2, 4, 6 OR 8 IN

PROCEEDING TO THE NEXT PREEMPTION PHASE.

PREEMPTION, THE ORIGINAL PREEMPTION PHASE SHALL TIME OUT BEFORE

IF ADDITIONAL PREEMPTION PHASES ARE ACTIVATED WHILE IN

FLASHING, ALL SIGNALS SHALL REMAIN FLASHING.

IF THE SIGNALS WHEN ACTIVATED BY AN EMERGENCY VEHICLE ARE

BEFORE GOING INTO EMERGENCY PREEMPTION.

SHALL TIME OUT FOLLOWED BY THE APPROPRIATE SELECTIVE CLEARANCES

IMMEDIATELY, FOLLOWED BY THE PED CLEAR INTERVAL. THIS INTERVAL

THE SIGNAL IS PREEMPTED, THE PED WALK INTERVAL SHALL TERMINATE

IF SIGNALS HAVE BEEN ACTUATED BY PEDESTRIAN PUSH BUTTON, AND

PHASES.

PREEMPTION AND "RED" INDICATIONS DISPLAYED FOR ALL OTHER

PREEMPTED PHASE SHALL REMAIN "GREEN" FOR THE DURATION OF SIGNAL

WHICH THE PREEMPTION OCCURS. THE "GREEN" INDICATIONS FOR THE

FOLLOWED BY SELECTIVE CLEARANCES DEPENDENT UPON THE PHASE IN

FOR THE PHASE GOVERNED BY THE APPROACHING EMERGENCY VEHICLE,

TERMINATE ALL GREEN INDICATIONS EXCEPT THE GREEN INDICATIONS

THE SIGNAL, WHEN ACTIVATED BY AN EMERGENCY VEHICLE, SHALL

ADJUSTED TO ACHEIVE MAXIMUM OPERATION.

LOCATION OF THE EMERGENCY VEHICLE DETECTORS ARE TO BE FIELD

THE INTERSECTION FOR THE APPROPRIATE APPROACH.

LIGHT AND SHALL FLASH WHEN THE EMERGENCY VEHICLE HAS CONTROL OF

THE EMERGENCY BEACON SHALL CONSIST OF A FLASHING WHITE FLOOD

OPERATION.

HILL RD. WITH A FAIL SAFE DEVICE FOR EACH DIRECTION OF

APPROACH OF PIONEER AVE., AND THE WESTBOUND APPROACH OF HARRIS

NORTHBOUND & SOUTHBOUND APPROACHES OF S.R. 0309, THE EASTBOUND

CONTROLLER TO BE EQUIPPED WITH EMERGENCY PREEMPTION FOR THE

1449 3 3

11-13-1947

JUNCTION BOX.

BE REUSED FROM EXISTING MASTARMS TO THE ADJACENT

ADEQUARE ROOM IS AVAILABLE, EXISTING CONDUIT CAN

REPLACE ALL CONDUIT AND JUNCTION BOXES. IF

PO

Q

C/1"

C/1"

C/1"

R1

R2

R3

R4

R5

R6

1 2

3 2

3 2

4 1 2

4 1 2

3 4 3 2

1 2

3 4 3 2

3 22

3 22

1 2

4 1 2

1 2

B1

D1

B3

B2

4 1 2

4 1 2

1 2

D3

3 4 3 2

3 4 3 2

7C/14

7C/14

5C/14

5C/14

5C/14

5C/14

5C/14

5C/14

5C/14

5C/14

5C/14

5C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

3C/14

9 1 2 5C/14

7 3 4 3 2 5C/14

5 4 1 2 5C/14

2 3 22 5C/14

- DETECTOR

- SIGNAL HEAD

5C/14 - CABLE (NO. OF CONDUCTORS/SIZE AWG)

- JUNCTION BOX

- TRAFFIC SIGNAL SUPPORT

- DETECTOR

- SIGNAL HEAD 3

* SIZE CABLE AS RECOMMENDED BY MANUFACTURER

CONTROLLER ASSEMBLY CC3

D4

D2

B4

6" LOWER CASE

8" UPPER CASE

0.8" BORDER WITH 2.5" CORNER RADII

BACKGROUND GREEN (REFLECTORIZED)

LEGEND AND BORDER WHITE (REFLECTORIZED)

CLEARVIEW 3W

6" LOWER CASE

8" UPPER CASE

0.8" BORDER WITH 2.5" CORNER RADII

BACKGROUND GREEN (REFLECTORIZED)

LEGEND AND BORDER WHITE (REFLECTORIZED)

CLEARVIEW 3W

PO

WCKEQUIPMENT UPGRADES

6-07-2002

6-30-2021

WIRING DIAGRAM

6 8

Memorial Hwy

6" LOWER CASE

8" UPPER CASE

0.8" BORDER WITH 2.5" CORNER RADII

BACKGROUND GREEN (REFLECTORIZED)

LEGEND AND BORDER WHITE (REFLECTORIZED)

CLEARVIEW 3W

3"

5"

96"

8"

84"

5"

3"

8"

8"

Pioneer

TOTAL - 96"

SPACE - 7.7"

y - 5.5" w - 9.6"

H - 7.3"

SPACE - 6.00"

l - 2.2" a - 7.4" i - 3.6" r - 5.0" o - 7.7" m - 10.3" e - 7.4"

M - 8.6"

SPACE - 7.7"

TOTAL - 84"

SPACE - 6.0"

l - 2.2" l - 4.1" i - 3.9"

H - 7.7"

SPACE - 6.00"

s - 4.6" i - 3.4" r - 5.0" r - 5.1" a - 7.4"

H - 7.5"

SPACE - 6.0"

- 9.0"

SPACE - 6.1"

Harris Hill

84"

5"

3"

8"

8"Pioneer

Harris Hill

TOTAL - 84"

SPACE - 19.8"

- 9.0"

SPACE - 6.0"

r - 3.3" e - 7.4" e - 7.0" n - 7.0" o - 7.7" i - 3.6"

P - 7.1"

SPACE - 6.1"

TOTAL - 84"

SPACE - 19.8"

r - 3.3" e - 7.4" e - 7.0" n - 7.0" o - 7.7" i - 3.6"

P - 7.1"

SPACE - 6.0"

- 9.0"

SPACE - 6.1"

TOTAL - 84"

SPACE - 6.0"

- 9.0"

SPACE - 6.0"

l - 2.2" l - 4.1" i - 3.9"

H - 7.7"

SPACE - 6.0"

s - 4.6" i - 3.4" r - 5.0" r - 5.1" a - 7.4"

H - 7.5"

SPACE - 6.1"

TJB

PERMIT NO. SHEET OF

DATE ISSUED DATE REVISED

DISTRICT COUNTY ROUTE SECTION SHEET

4-0 LUZERNE

DISTRICT TRAFFIC ENGINEER DATE

MUNICIPAL OFFICIAL DATE

COUNTY:

MUNICIPALITY:

INTERSECTION:

REVIEWED:

RECOMMENDED:

SCALE:

LUZERNE COUNTY

25 50 75

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

P i o n e e d g n

PROFESSIONAL

REGISTERED

F O

H

TL

AEWN

O

M M

O C

A I

N A

VLYS

N

N

E P

ENGINEER

WENDY C. KELLEY

No. PE075354

DATE REVISION BY

O P

E R

A T

O R

F I

M

A c c o u n t s

P A

D O

T

P A

D O

T g n r r i d o r

D E

S I

G N

C T

D G

N

C O

N S

T R

S i g n a n s

S

S I

G

P L

A

P i o n e e d g n

KINGSTON TOWNSHIP

KINGSTON TOWNSHIP

GENERAL NOTES

BW/4"

BW/6"

Y

DY/4"

File details come from the government source that posted it. Updated .