This document is an Erosion and Sedimentation Control Plan for a structure replacement project on Harris Hill Road (T-783) over Toby Creek in Kingston Township, Luzerne County, Pennsylvania, prepared by Alfred Benesch & Company. The project involves replacing an existing stacked stone and concrete arch culvert with a new single-span composite prestressed concrete bridge. The total project disturbance area is 0.6 acres, and the work includes clearing, grading, bridge construction, roadway improvements, and implementing various erosion control best management practices (BMPs). The project is subject to Pennsylvania Department of Environmental Protection (PADEP) regulations and will require adherence to specific erosion and sediment control guidelines.
The plan details comprehensive erosion control measures, including the use of compost filter socks, rock construction entrances, inlet protection, concrete washout facilities, and temporary stream crossings. The project site contains Oquaga and Lordstown extremely stony silt loams with varying soil limitations. Specific stabilization techniques include seeding with native grass mixes, applying mulch, and using erosion control blankets. The construction sequence is carefully outlined to minimize environmental impact, with strict requirements for sediment control, site inspection, and restoration. Stream restrictions are noted, including considerations for migratory fish and cold water fishery habitat during specific times of the year.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 7
GENERAL NOTES
EROSION AND SEDIMENTATION CONTROL
(INCLUDING MAINTENANCE PROGRAM)
EROSION CONTROL POLICIES
AND THE INSPECTOR IN CHARGE:
ACCORDANCE WITH THE INSTRUCTIONS OF THE DEPARTMENT OF ENVIRONMENTAL PROTECTION
PROJECT CONFORMS WITH THE FOLLOWING GUIDELINES AS THEY ARE APPLICABLE AND IN
PENNSYLVANIA TO CONTROL EROSION, IT IS REQUIRED THAT THE CONTRACTOR FOR THIS
IN ACCORDANCE WITH THE CURRENT POLICIES AND PRACTICES IN THE COMMONWEALTH OF
WSL GJB
SYMBOL
MAP UNIT
AND STREETS
LOCAL ROADS
SOURCE
ROADFILL
SOIL LIMITATIONS AND RATINGS
TOPSOIL SOURCE
SOILS INFORMATION, LIMITATIONS AND RESOLUTIONS
MAP UNIT NAME
SYMBOL
MAP UNIT
SOILS LEGEND
PROJECT DISTURBANCE
APPROPRIATE EROSION CONTROL BMPS.
AND PROPERLY STABILIZED. ALL EXCESS EXCAVATION WILL BE DISPOSED OF AT A SITE WITH
MATERIAL, OTHERWISE SUITABLE FILL FROM AN OFFSITE SOURCE WILL NEED TO BE HAULED TO THE SITE
OFFSITE SOURCES IF NEEDED. ALL EXCAVATION DEEMED AS SUITABLE MATERIAL MAY BE USED AS FILL
THE SOIL LIMITATIONS OR CHARACTERISTICS WILL AFFECT THE PROJECT. TOPSOIL WILL BE USED FROM
COMPACTED FILL AREAS WITHIN THE ROADWAY CROSS SECTION, IT IS NOT ANTICIPATED THAT ANY OF
RESOLUTIONS: SINCE THE APPROACH ROADWAY AREAS OF THE PROJECT WILL OCCUR ON PREVIOUSLY
HYDRIC RATING
Ps
OXF
POPE SOILS
OQUAGA AND LORDSTOWN EXTREMELY STONY SILT LOAMS STEEP
Ps
OXF
SOMEWHAT LIMTED
VERY LIMITED
GOOD
POOR
FAIR
POOR
P E
N
N S Y L V
A
N
I A
C O
M
M O
NW EALT
H
O
F
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
DESCRIBED ON THE PLAN DRAWINGS.
ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE MANNER 18.
SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR SURFACE WATER.
MANNER DESCRIBED IN THIS PLAN. IN NO CASE SHALL THE SEDIMENT BE WASHED,
THE CONSTRUCTION SITE BY THE END OF EACH WORK DAY AND DISPOSED IN THE
SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED TO 17.
TIME OF INSPECTION.
ON THE SITE AND BE MADE AVAILABLE TO REGULATORY AGENCY OFFICIALS AT THE
DEFICIENCIES FOUND AND THE DATE THEY WERE CORRECTED SHALL BE MAINTAINED
A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS ANY 16.
REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
PERFORMED IMMEDIATELY. IF E&S BMPS FAIL TO PERFORM AS EXPECTED,
REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING MUST BE
PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR,
AND SEDIMENT BMPS AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL
MAINTAINED PROPERLY. MAINTENANCE MUST INCLUDE INSPECTIONS OF ALL EROSION
UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS MUST BE 15.
DISTURBED AREA THAT WILL NOT BE DISTURBED IN 4 DAYS.
THE CONTRACTOR MUST IMPLEMENT TEMPORARY STABILIZATION MEASURE IN ANY 14.
DONE ACCORDING TO THE PROCEDURE DESCRIBED IN THIS PLAN.
ALL PUMPING OF WATER FROM ANY WORK AREA OVER UNDISTURBED AREAS, SHALL BE 13.
SUBSTANCE BUT QUALIFYING AS CLEAN FILL DUE TO ANALYTICAL TESTING.
FOR ANY FILL MATERIAL AFFECTED BY A SPILL OR RELEASE OF A REGULATED
SITE IS CLEAN FILL. FORM FP-001 MUST BE RETAINED BY THE PROPERTY OWNER
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON 12.
PADEP FULLY IMPLEMENTED PRIOR TO BEING ACTIVATED.
ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN APPROVED BY 11.
BE BURNED, BURIED, DUMPED, OR DISCHARGED AT THE SITE.
SEQ. NO BUILDING MATERIALS OR WASTES OR UNUSED BUILDING MATERIALS SHALL
MANAGEMENT REGULATIONS AT 25 PA. CODE 260.1 ET. SEQ., 271.1, AND 287.1 ET.
RECYCLED OR DISPOSED OF IN ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE
ALL BUILDING MATERIALS AND WASTES MUST BE REMOVED FROM THE SITE AND 10.
FOR EROSION AND SEDIMENT POLLUTION AND NOTIFY THE OWNER.
IMPLEMENT APPROPRIATE BEST MANAGEMENT PRACTICES TO MINIMIZE THE POTENTIAL
FOR ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL 9.
FEET. STOCKPILE SLOPES MUST BE 2H:1V OR FLATTER.
MANNER SHOWN ON THE PLAN DRAWINGS. STOCKPILE HEIGHTS MUST NOT EXCEED 35
STABILIZED BY VEGETATION. EACH STOCKPILE SHALL BE PROTECTED IN THE
COMPLETE THE FINISH GRADING OF ALL EXPOSED AREAS THAT ARE TO BE
AT THE LOCATION(S) SHOWN ON THE PLAN MAP(S) IN THE AMOUNT NECESSARY TO
TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE STOCKPILED 8.
OPERATIONS BEGIN.
MUST BE CLEARLY MARKED AND FENCED OFF BEFORE CLEARING AND GRUBBING
THE LIMIT OF DISTURBANCE BOUNDARIES SHOWN ON THE PLAN MAPS. THESE AREAS
AT NO TIME SHALL CONSTRUCTION VEHICLES BE ALLOWED TO ENTER AREAS OUTSIDE 7.
IN THIS E&S PLAN.
THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE FUNCTIONING AS DESCRIBED
PHASE OF THE PROJECT UNTIL THE E&S BMPS SPECIFIED BY THE BMP SEQUENCE FOR
CLEARING, GRUBBING AND TOPSOIL STRIPPING MAY NOT COMMENCE IN ANY STAGE OR
DESCRIBED IN EACH STAGE OF THE CONSTRUCTION SEQUENCE. GENERAL SITE
CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO THOSE AREAS 6.
REMOVE TREES, VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL.
AREAS TO BE FILLED SHOULD BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO 5.
PRIOR TO IMPLEMENTATION.
BE APPROVED IN WRITING FROM THE LOCAL CONSERVATION DISTRICT OR PADEP
SEQUENCE PROVIDED ON THE PLAN DRAWINGS. DEVIATION FROM THE SEQUENCE MUST
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE 4.
EXISTING UNDERGROUND UTILITIES.
SYSTEM INC. SHALL BE NOTIFIED AT 1-800-242-1776 FOR THE LOCATION OF
EXPANDING INTO AN AREA PREVIOUSLY UNMARKED, THE PENNSYLVANIA ONE CALL
AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, OR 3.
PROTECTION (PADEP) TO AN ON-SITE PRECONSTRUCTION MEETING.
AND/OR A REPRESENTATIVE FROM THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL
PLAN PREPARER, A REPRESENTATIVE FROM THE LOCAL CONSERVATION DISTRICT
ALL CONTRACTORS, THE LANDOWNER, APPROPRIATE MUNICIPAL OFFICIALS, THE E&S
INCLUDING CLEARING AND GRUBBING, THE OWNER AND/OR OPERATOR SHALL INVITE
AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, 2.
REVIEW AND APPROVAL AT ITS DISCRETION.
CHANGES. THE OWNER MAY REQUIRE A WRITTEN SUBMITTAL OF THOSE CHANGES FOR
OF ANY CHANGES TO THE APPROVED PLAN PRIOR TO IMPLEMENTATION OF THOSE
AVAILABLE AT THE PROJECT SITE AT ALL TIMES. THE OWNER SHALL BE NOTIFIED
SEDIMENT CONTROL (E&S) PLAN. A COPY OF THE APPROVED DRAWINGS MUST BE
AND FILL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED EROSION AND
ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS 1.
TO REMOVAL/CONVERSION OF THE E&S BMPS.
CONTACT THE LOCAL CONSERVATION DISTRICT OR PADEP FOR AN INSPECTION PRIOR
STABILIZATION OF ALL DISTURBED AREAS, THE OWNER AND/OR OPERATOR SHALL
UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT 35.
FILLS SHALL NOT BE PLACED ON SATURATED OR FROZEN PARTICLES.34.
NOT BE INCORPORATED INTO FILLS.
FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE MATERIALS SHALL 33.
PREVENT CONSTRUCTION OF SATISFACTORY FILLS.
OTHER FOREIGN OR OBJECTIONABLE MATERIALS THAT WOULD INTERFERE WITH OR
FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR 32.
SPECIFIED ON THE PLAN MAPS AND/OR DETAIL SHEETS.
STEEPER WITHIN 50 FEET OF A SURFACE WATER AND ON ALL OTHER DISTURBED AREAS
EROSION CONTROL BLANKETING SHALL BE INSTALLED ON ALL SLOPES 3H:1V OR 31.
GROUNDWATER SYSTEMS.
DRAWINGS. IN NO CASE SHALL IT BE ALLOWED TO ENTER ANY SURFACE WATERS OR
CONCRETE WASH WATER SHALL BE HANDLED IN THE MANNER DESCRIBED ON THE PLAN 30.
IN MISDEMEANOR CRIMINAL PENALTIES FOR EACH VIOLATION.
PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL PENALTIES, AND UP TO $25,000
LAW. THE CLEAN STREAMS LAW PROVIDES FOR UP TO $10,000 PER DAY IN CIVIL
DEPARTMENT AS DEFINED IN SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS
ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL PENALTIES BEING INSTITUTED BY THE
CORRECTIVE ACTION TO RESOLVE FAILURE OF E&S BMPS MAY RESULT IN
RUNOFF FROM LEAVING THE CONSTRUCTION SITE, OR FAILURE TO TAKE IMMEDIATE
FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT SEDIMENT-LADEN 29.
CONTACT THE OWNER TO SCHEDULE A FINAL INSPECTION.
STABILIZATION OF ALL DISTURBED AREAS, THE OWNER AND/OR OPERATOR SHALL
UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT 28.
ONLY DURING THE GERMINATING SEASON.
REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS SHOULD BE DONE
OF THE BMPS SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO ENSURE RAPID
STORMWATER MANAGEMENT BMPS. AREAS DISTURBED DURING REMOVAL OR CONVERSION
SEDIMENT BMPS MUST BE REMOVED OR CONVERTED TO PERMANENT POST CONSTRUCTION
AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND 27.
APPROVED BY THE OWNER.
ARE PERMANENTLY STABILIZED OR UNTIL THEY ARE REPLACED BY ANOTHER BMP
E&S BMPS MUST REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS TRIBUTARY TO THEM 26.
CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND FILL SLOPES SHALL BE
VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY
PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% 25.
PERMANENT STABILIZATION SPECIFICATIONS.
REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED IN ACCORDANCE WITH THE
TEMPORARY STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE
BE REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE
APPLIED AS DESCRIBED IN THE PLAN. AREAS NOT AT FINISHED GRADE, WHICH WILL
DURING NON-GERMINATING MONTHS, MULCH OR PROTECTIVE BLANKETING SHALL BE
SUBAREA OF THE PROJECT, THE OPERATOR SHALL STABILIZE ALL DISTURBED AREAS.
IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA OR 24.
STANDARDS OF THIS PLAN.
OTHERWISE SHOWN ON THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO THE
BE VEGETATED. SEEDED AREAS WITHIN 50 FEET OF A SURFACE WATER, OR AS
FINISHED GRADE. CUT SLOPES IN COMPETENT BEDROCK AND ROCK FILLS NEED NOT
ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY UPON REACHING 23.
OTHER APPROVED METHODS.
ACCORDANCE WITH THE STANDARD AND SPECIFICATION FOR SUBSURFACE DRAIN OR
SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE HANDLED IN 22.
INCHES IN THICKNESS.
ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 9 21.
ACCORDANCE WITH LOCAL REQUIREMENTS OR CODES.
SUPPORT BUILDINGS, STRUCTURES AND CONDUITS, ETC. SHALL BE COMPACTED IN
SETTLEMENT, SUBSIDENCE OR OTHER RELATED PROBLEMS. FILL INTENDED TO
ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION, SLIPPAGE, 20.
MINIMUM OF 2 INCHES OF TOPSOIL.
IN PLACE PRIOR TO SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A
TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A MINIMUM 4 INCHES OF TOPSOIL
TO 5 INCHES 6 TO 12 INCHES ON COMPACTED SOILS PRIOR TO PLACEMENT OF
AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 3 19.
PROJECT DISTURBANCE = 0.6 ACRES
RTF
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\01_ES_GenNotes.dgn (Default)mmattrazzo 08\03\2022 18:11:42
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
Pennsylvania One Call System Serial Number excavation
10 business days prior to the start of than 3 business days nor more than
Dial 8-1-1 or 1-800-242-1776 not less
20191561674
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
HARRIS HILL ROAD (T-783)
8/3/2022
2 7
CONSTRUCTION SEQUENCE
WSL JAH
NOTES
EROSION AND SEDIMENTATION CONTROL
OUTLET PROTECTION
RIPRAP APRON
SECTION A-A
SECTION B-B
PLAN
d
AA
B
B
LESS THAN 6 INCHES.
STONE DIAMETER BUT NOT
d = 1.5 TIMES THE MAXIMUM
OUTLET NO.
D o
D o
W
La
0% SLOPE
0% SLOPE
(in)
Do
PIPE DIA.
(MAX OR MIN)
CONDITION
TAILWATER
(CFS)
Q
(FPS)
V
(ft)
La
(ft)
W
MIN
SIZE
RIPRAP
NTS
OUTFALL PIPE 18 7.3 R-5
(in) d
11.5 11.1
CLASS 4, TYPE A
GEOTEXTILE,
CLASS 4, TYPE A
GEOTEXTILE,
WHERE NOTED.
EACH STEP OF THE SEQUENCE SHALL BE COMPLETED BEFORE PROCEEDING TO THE NEXT STEP, EXCEPT
IMPLEMENTATION. CLEARING AND GRUBBING SHALL BE LIMITED TO THOSE AREAS DESCRIBED IN EACH STAGE.
THE PLAN DRAWINGS. DEVIATION FROM THAT SEQUENCE MUST BE APPROVED BY THE OWNER PRIOR TO
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE SEQUENCE PROVIDED ON
RTF
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
IS NOT TO BE USED)
(STREAMBED MATERIAL
CLEAN ROCK FILL
SECTION
NTS
TEMPORARY STREAM CROSSING - MULTIPLE PIPES
ALL MATERIALS SHALL BE DISPOSED OF PROPERLY AND DISTURBED AREAS STABILIZED.
AS SOON AS THE TEMPORARY CROSSING IS NO LONGER NEEDED, IT SHALL BE REMOVED.
WITHIN 24 HOURS OF THE INSPECTION.
3. SEDIMENT DEPOSITS ON THE CROSSING OR ITS APPROACHES SHALL BE REMOVED
AND BEFORE ANY SUBSEQUENT USE.
2. DAMAGED CROSSINGS SHALL BE REPAIRED WITHIN 24 HOURS OF THE INSPECTION
1. TEMPORARY STREAM CROSSINGS SHALL BE INSPECTED ON A DAILY BASIS.
MAINTENANCE:
MINIMUM DISTANCE BETWEEN CULVERT PIPES
ABOVE 72 X 44
25 X 16 TO 72 X 44
18 X 11 TO 25 X 16
PIPE ARCH SIZE (IN)
72" TO 120"
24" TO 72"
12" TO 24"
PIPE DIAMETER (D)
30"
1/3 SPAN OF PIPE ARCH
12"
MINIMUM DISTANCE (FF)
36"
1/2 DIAMETER (D)
12"
MINIMUM DISTANCE (F)
18" (TYP) F
FILL OVER CULVERT
1 FOOT MIN DEPTH OF ROADWAY
MOVEMENTS.
EROSION AND SUBSURFACE CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER
OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED
STABILIZATION WHEN IT HAS A MINIMUM UNIFORM 70 PERCENT PERENNIAL VEGETATIVE COVER OR
STABILIZED IMMEDIATELY. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL
BMPS MUST BE REMOVED. AREAS DISTURBED DURING REMOVAL OF THE BMPS MUST BE
AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND SEDIMENT 11.
STABILIZE ALL REMAINING DISTURBED AREAS.10.
COMPLETE ALL REMAINING ROADWAY IMPROVEMENTS.9.
BACKFILL AND STABILIZE SLOPES AND REMOVE TEMPORARY DIVERSION DEVICES.8.
COMPLETE BRIDGE CONSTRUCTION AND PAVING ACTIVITIES.7.
OF THE EXISTING STRUCTURE.
COMPLETE SCOUR PROTECTION BY USING CONCRETE AND GROUT AT THE UNDERMINED AREAS 6.
MATERIALS THAT FALL INTO THE STREAM IMMEDIATELY.
IMPROVEMENTS. DO NOT ALLOW ANY CONSTRUCTION DEBRIS TO ENTER THE STREAM. REMOVE ANY
REMOVE BRIDGE ARCH AND ALL EXISTING FEATURES REQUIRED TO INSTALL THE PROPOSED 5.
AND CLEAN STONE IN THE STREAM TO DIVERT FLOW THROUGH THE CONSTRUCTION AREA.
CONSTRUCT THE TEMPORARY ACCESS ROAD, AND PLACE FOUR (4) TEMPORARY 18" PIPES 4.
INSTALLATION OF THE PROPOSED INLETS, INLET PROTECTION MUST BE INSTALLED.
CONSTRUCT INLETS 1 AND 2 AND PIPE TO DIVERT FLOW AROUND WORK AREA. UPON 3.
CONCRETE WASHOUT.
SOCK, TEMPORARY DIVERSION DEVICES, INLET PROTECTION, PUMPED WATER FILTER BAG, AND
CONTROL SEDIMENT DURING THESE OPERATIONS. TEMPORARY CONTROLS INCLUDE COMPOST FILTER
PRIOR TO THE START OF BRIDGE WORK, PLACE TEMPORARY EROSION CONTROL FEATURES TO 2.
ABOVE GROUND ELEVATION.
CLEAR THE SITE AS REQUIRED. THIS WORK INCLUDES REMOVAL OF SMALL TREES AND BRUSH 1.
MOUNTABLE BERM USED TO PROVIDE PROPER COVER OVER PIPE*
EXISTING GROUND
GEOTEXTILE
NECESSARY
PIPE AS
EARTH FILL
EXISTING ROADWAY
ROADWAY
EXISTING
PROFILE
PLAN VIEW
ROCK CONSTRUCTION ENTRANCE
50' MINIMUM
3'
NTS
MIN 8" AASHTO #1
(6" MIN) *
MOUNTABLE BERM
M
IN
M
IN
M
IN
SHALL BE SIZED APPROPRIATELY FOR SIZE OF DITCH BEING CROSSED.
PROPER PIPE COVER AS SPECIFIED BY MANUFACTURER IS NOT OTHERWISE PROVIDED. PIPE
3. MOUNTABLE BERM SHALL BE INSTALLED WHEREVER OPTIONAL CULVERT PIPE IS USED AND
TO ENTERING ROCK CONSTRUCTION ENTRANCE.
2. RUNOFF SHALL BE DIVERTED FROM ROADWAY TO A SUITABLE SEDIMENT REMOVAL BMP PRIOR
OVER FULL WIDTH OF ENTRANCE.
1. REMOVE TOPSOIL PRIOR TO INSTALLATION OF ROCK CONSTRUCTION ENTRANCE. EXTEND ROCK
NOTE:
DRAINAGE COURSES IS NOT ACCEPTABLE.
ROADWAY OR SWEEPING THE DEPOSITS INTO ROADWAY DITCHES, SEWERS, CULVERTS, OR OTHER
FOOT INCREMENTS UNTIL CONDITION IS ALLEVIATED OR INSTALL WASH RACK. WASHING THE
BEING DEPOSITED ON ROADWAY, EXTEND LENGTH OF ROCK CONSTRUCTION ENTRANCE BY 50
RETURNED TO THE CONSTRUCTION SITE IMMEDIATELY. IF EXCESSIVE AMOUNTS OF SEDIMENT ARE
FOR THIS PURPOSE. ALL SEDIMENT DEPOSITED ON PAVED ROADWAYS SHALL BE REMOVED AND
TO THE SPECIFIED DIMENSIONS BY ADDING ROCK. A STOCKPILE SHALL BE MAINTAINED ON SITE
MAINTENANCE: ROCK CONSTRUCTION ENTRANCE THICKNESS SHALL BE CONSTANTLY MAINTAINED
CROSSING.
SEDIMENT REMOVAL BMP BEFORE IT REACHES THE ROCK APPROACH TO THE
3. RUNOFF FROM THE ROADWAY SHALL BE DIVERTED OFF THE ROADWAY AND INTO A
2. PIPES SHALL EXTEND BEYOND THE TOE OF THE ROADWAY.
IMPRACTICAL TO AFFECT THE CROSSING WITHOUT MULTIPLE SPANS (SECTION 105.162).
LESS THAN 15 FEET SHALL BE BY ONE SPAN, EXCEPT WHERE CONDITIONS MAKE IT
LOSSES SHALL BE AVOIDED TO THE MAXIMUM EXTENT PRACTICABLE. CROSSINGS OF
COLLECT DEBRIS, CONTRIBUTE TO THE FORMATION OF ICE JAMS AND INCREASE HEAD
1. MULTIPLE PIPES AND MULTIPLE SPAN BRIDGES AND CULVERTS WHICH MAY TEND TO
NOTE:
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\02_ES_NOTES.dgn (Default)mmattrazzo 08\03\2022 18:11:44
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
SPACED 5' ON CENTERS
2"X2"X36" WOOD STAKES
FILTER SOCK
24" COMPOST
MIN 10-MIL THICKNESS
PLASTIC SHEETING
NTS
FILTER RING
ON UPSLOPE SIDE OF
SOCK 4' MIN OVERLAP
24" COMPOST FILTER
ON CENTERS
STAKES SPACED 5'
2"X2"X36" WOOD
FILTER RING
WASHOUT WATER INTO
DIRECT CONCRETE
SOCK MAY BE STACKED ONTO DOUBLE 24" DIAMETER SOCKS IN PYRAMIDAL CONFIGURATION FOR ADDED HEIGHT.
COMPOST SOCKS MAY BE STACKED AND STAKED SO AS TO FORM A TRIANGULAR CROSS SECTION. 18-INCH DIAMETER FILTER
PLASTIC LINERS SHOULD BE REPLACED WITH EACH CLEANING OF THE WASHOUT FACILITY.
ACCUMULATED MATERIALS SHOULD BE REMOVED WHEN THEY REACH 75% CAPACITY.
INSPECT WASHOUT FACILITIES DAILY. DEACTIVATE AND REPAIR OR REPLACE DAMAGE OR LEAKING WASHOUTS IMMEDIATELY.
THE CLEANOUT LEVEL.
WATERTIGHT, AND APPROPRIATELY SIZED. ACCUMULATED MATERIALS MUST BE PROPERLY DISPOSED OF WHEN THEY REACH
THAT THE CONTAINERS ARE INTENDED BY THE MANUFACTURER FOR USE AS CONCRETE WASHOUT BMPS, THAT THEY ARE
PREFABRICATED WASHOUT CONTAINERS MAY BE USED AS A SUITABLE ALTERNATIVE. CARE SHOULD BE TAKEN TO ENSURE
NOTES:
FILTER RING HEIGHT
WATER IS 50% OF
CONCRETE WASHOUT
MAXIMUM DEPTH OF
FILTER SOCK
COMPOST
PLACED 10' O.C.
2" x 2" WOODEN STAKES
AREA
DISTURBED
F L O
WF
L O
W
DISTURBED AREA
BLOWN / PLACED FILTER MEDIA
2" x 2" WOODEN STAKES PLACED 10' O.C.
COMPOST FILTER SOCK
12" MIN
EXISTING CONTOURS
UNDISTURBED AREA
AREA
UNDISTURBED
SECTION VIEW
PLAN VIEW
COMPOST FILTER SOCK
NTS
MATERIAL TYPE 3 MIL HDPE 5 MIL HDPE 5 MIL HDPE
(MFPP)
POLYPROPYLENE
MULTI-FILAMENT
(HDMFPP)
POLYPROPYLENE
MULTI-FILAMENT
HEAVY DUTY
CHARACTERISTICS
MATERIAL
DEGRADABLE
PHOTO-
DEGRADABLE
PHOTO-
DEGRADABLE
BIO-
DEGRADABLE
PHOTO-
DEGRADABLE
PHOTO-
32"
24"
18"
12"
32"
24"
18"
12"
32"
24"
18"
12"
32"
24"
18"
12"
18"
12"
DIAMETERS
SOCK
MESH OPENING 3/8" 3/8" 3/8" 3/8" 1/8"
26 PSI 26 PSI 44 PSI 202 PSI
STRENGTH
TENSILE
(ASTM-G-155)
STRENGTH
ORIGINAL
STABILITY %
ULTRAVIOLET
1000 HR
23% AT
1000 HR
23% AT
1000 HR
100% AT
1000 HR
100% AT
LONGEVITY
FUNCTIONAL
MINIMUM
6 MONTHS 9 MONTHS 6 MONTHS 1 YEAR 2 YEARS
TWO-PLY SYSTEMS
HDPE BIAXIAL NET
CONTINUOUSLY WOUND
FUSION-WELDED JUNCTURES
3/4" X 3/4" MAX APERTURE SIZE
MECHANICALLY FUSED VIA NEEDLE PUNCH)
(WOVEN LAYER AND NON-WOVEN FLEECE
COMPOSITE POLYPROPYLENE FABRIC
3 /16" MAX APERTURE SIZE
INNER CONTAINMENT NETTING
OUTER FILTRATION MESH
SOCK FABRICS COMPOSED OF BURLAP MAY BE USED ON PROJECTS LASTING 6 MONTHS OR LESS.
COMPOST SOCK FABRIC MINIMUM SPECIFICATIONS
SOLUBLE SALT CONCENTRATION
PARTICLE SIZE
MOISTURE CONTENT
pH
ORGANIC PORTION
ORGANIC MATTER CONTENT
COMPOST STANDARDS
ALTERNATIVE.
TABLE BELOW. THE STANDARDS CONTAINED IN THE PENNDOT PUBLICATION 408 ARE AN ACCEPTABLE
THE PHYSICAL PARAMETERS OF THE COMPOST SHOULD COMPLY WITH THE STANDARDS AS SHOWN IN THE
THE ORGANIC COMPONENT OF THE MIX.
CHIPS, GROUND CONSTRUCTION DEBRIS OR REPROCESSED WOOD PRODUCTS ARE NOT ACCEPTABLE AS
PRODUCT SHOULD NOT RESEMBLE THE RAW MATERIAL FROM WHICH IT WAS DERIVED. WOOD AND BARK
SHOULD BE SEASONABLY FREE (<1% BY DRY WEIGHT) OF MAN-MADE FOREIGN MATTER. THE COMPOST
SHOULD BE AEROBICALLY COMPOSTED. THE COMPOST SHOULD POSSESS NO OBJECTIONABLE ODORS AND
FOOD, STUMP GRINDINGS, AND YARD OR WOOD/BARK ORGANIC MATTER SOURCES. THE COMPOST
COMPOST SHOULD BE A WELL DECOMPOSED, WEED-FREE ORGANIC MATTER DERIVED FROM AGRICULTURE, CONCRETE WASHOUT - SECTION VIEW
CONCRETE WASHOUT
FLOW
OPEN AND THE MULCH SPREAD AS A SOIL SUPPLEMENT.
MAY BE LEFT IN PLACE AND VEGETATED OR REMOVED. IN THE LATTER CASE, THE MESH SHALL BE CUT
7. UPON STABILIZATION OF THE AREA TRIBUTARY TO THE SOCK, STAKES SHALL BE REMOVED. THE SOCK
RECOMMENDATIONS.
AFTER 1 YEAR. POLYPROPYLENE SOCKS SHALL BE REPLACED ACCORDING TO MANUFACTURER'S
6. BIODEGRADABLE FILTER SOCKS SHALL BE REPLACED AFTER 6 MONTHS; PHOTODEGRADABLE SOCKS
INSPECTION.
REPAIRED ACCORDING TO MANUFACTURER'S SPECIFICATIONS OR REPLACED WITHIN 24 HOURS OF
5. SOCKS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT. DAMAGED SOCKS SHALL BE
THE SOCK AND DISPOSED IN THE MANNER DESCRIBED ELSEWHERE IN THE PLAN.
4. ACCUMULATED SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE ABOVE GROUND HEIGHT OF
3. TRAFFIC SHALL NOT BE PERMITTED TO CROSS FILTER SOCKS.
BY THE MANUFACTURER.
(363-2134-008). STAKES MAY BE INSTALLED IMMEDIATELY DOWNSLOPE OF THE SOCK IF SO SPECIFIED
REPORT AND/OR THE PADEP EROSION AND SEDIMENT POLLUTION CONTROL PROGRAM MANUAL
SLOPE LENGTH ABOVE ANY SOCK SHALL NOT EXCEED THAT IN THE EROSION AND SEDIMENT CONTROL
BE EXTENDED AT LEAST 8 FEET UP SLOPE AT 45 DEGREES TO THE MAIN SOCK ALIGNMENT. MAXIMUM
2. COMPOST FILTER SOCK SHALL BE PLACED AT EXISTING LEVEL GRADE. BOTH ENDS OF THE SOCK SHALL
STANDARDS AS SHOWN IN TABLE BELOW.
1. SOCK FABRIC SHALL MEET STANDARDS AS SHOWN IN TABLE BELOW. COMPOST SHALL MEET THE
NOTES:
5.0 DS/M (MMHOS/CM) MAXIMUM
30%-50% PASS THROUGH 3/8" SIEVE
30% - 60%
5.5 - 8.5
FIBROUS AND ELONGATED
25% - 100% (DRY WEIGHT BASIS)
3 7
DETAILS
EROSION AND SEDIMENTATION CONTROL
WSL JAH RTF
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
COMPOST FILTER SOCK SCHEDULE
21+05, LT
20+89, RT
20+61, RT
20+57, LT
STATION
SIZE
LENGTH (FT)
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\03_ES_DET01.dgn (Default)mmattrazzo 08\03\2022 18:11:45
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
AND STAPLED.
OVERLAPPED 4" (MIN.)
BLANKET EDGES
WDIRECTION OF WATER FLO
ROLL BLANKETS IN
STARTING AT TOP OF SLOPE,
COMPACT SOIL.
STAPLE, BACKFILL AND
IN 6" x 6" ANCHOR TRENCH, INSTALL BEGINNING OF ROLL
BLANKET.
PRIOR TO INSTALLATION OF
LIME, FERTILIZER, & SEED)
(INCLUDING APPLICATION OF
PREPARE SEED BED
BEING BLANKETED.
STEEPNESS AND LENGTH OF SLOPE
RECOMMENDED STAPLING PATTERN FOR
REFER TO MANUFACTURER'S
(SHINGLE STYLE). STAPLE SECURELY.
BLANKET OVERLYING THE DOWNSLOPE BLANKET
OVERLAP BLANKET ENDS 6" (MIN.) WITH THE UPSLOPE
.GOOD SOIL CONTACT
STRETCHED; IT MUST MAINTAIN
THE BLANKET SHOULD NOT BE
EROSION CONTROL BLANKET INSTALLATION
NTS
EROSION CONTROL BLANKET STAPLE PATTERNS
(INCLUDING 2:1)
BETWEEN 2:1 AND 1:1
ANCHOR PATTERN FOR SLOPES
(INCLUDING 3:1)
BETWEEN 3:1 AND 2:1
ANCHOR PATTERN FOR SLOPES
SLOPES FLATTER THAN 3:1
ANCHOR PATTERN FOR
PLACE 2 ANCHORS/SY
PLACE 1.5 ANCHOR/SY
PLACE 1 ANCHOR/SY
3'-0" 3
ANCHORS(TYP)
3'-0"
" 4
"3'-0"
1'-6" 1'-6"
ANCHORS(TYP)
ANCHORS(TYP)
SEE DETAIL
ANCHORING POST
UNDISTURBED AREA
SECTION
SEE
MATERIAL
STOCKPILED
MATERIAL
STOCKPILE
MIN
6'-0"
FILL THIS AREA
MATERIAL SHALL NOT
STOCKPILE CONTROL DETAIL
SECTION
NTS
2 (MAX)
F
E E
T
M A
X
(SEE DETAIL)
SILT FENCE.
12" HEIGHT OR EQUIVALENT
COMPOST FILTERSOCK,
(SEE DETAIL)
SILT FENCE.
12" HEIGHT OR EQUIVALENT
COMPOST FILTERSOCK,
NTS
4 7
DETAILS
EROSION AND SEDIMENTATION CONTROL
WSL JAH RTF
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
FEET OF A SURFACE REGARDLESS OF SLOPE.
7. EROSION CONTROL BLANKET SHOULD BE USED FOR ALL SEEDED AREAS WITHIN 50
RESTORED OR REPLACED WITHIN 4 CALENDAR DAYS.
THROUGHOUT THE BLANKETED AREA. DAMAGED OR DISPLACED BLANKETS SHALL BE
UNTIL PERENNIAL VEGETATION IS ESTABLISHED TO A MINIMUM UNIFORM 70% COVERAGE
6. BLANKETED AREAS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT
RECOMMENDATIONS.
5. THE BLANKET SHALL BE STAPLED IN ACCORDANCE WITH THE MANUFACTURER'S
MAINTAIN DIRECT CONTACT WITH SOIL. DO NOT STRETCH BLANKET.
THROUGHOUT ENTIRE LENGTH. LAY BLANKET LOOSELY AND STAKE OR STAPLE TO
4. BLANKET SHALL HAVE GOOD CONTINUOUS CONTACT WITH UNDERLYING SOIL
3. SLOPE SURFACE SHALL BE FREE OF ROCKS, CLODS, STICKS, AND GRASS.
SLOPE.
2. PROVIDE ANCHOR TRENCH AT TOE OF SLOPE IN SIMILAR FASHION AS AT TOP OF
PLAN DRAWINGS PRIOR TO INSTALLING THE BLANKET.
1. SEED AND SOIL AMENDMENTS SHALL BE APPLIED ACCORDING TO THE RATES IN THE
NOTE:
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\04_ES_DET02.dgn (Default)mmattrazzo 08\03\2022 18:11:47
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
5 7
DETAILS
EROSION AND SEDIMENTATION CONTROL
WSL JAH
FILTER BAG INLET PROTECTION
NTS
ISOMETRIC VIEW
TYPE M INSTALLATION DETAIL
TYPE C INSTALLATION DETAIL
RUBBER BLOCK
2" x 2" x 3/4"
(1/4" NYLON ROPE)
EXPANSION RESTRAINT
RUBBER BLOCK
2" x 2" x 3/4"
(1/4" NYLON ROPE)
EXPANSION RESTRAINT
FROM INLET
REMOVAL
FOR BAG
1" REBAR
INLET GRATE
4'
LENGTH
WI
DTH
OR FILTER TUBE
SANDBAG, FILTER LOG, COMPOST SOCK
6. DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
BAGS ACCORDING TO THE PLAN NOTES.
INITIATED IMMEDIATELY AFTER THE INSPECTION. DISPOSE OF ACCUMULATED SEDIMENT AS WELL AS ALL USED
SUPPLY SHALL BE MAINTAINED ON SITE FOR REPLACEMENT OF BAGS. ALL NEEDED REPAIRS SHALL BE
AS TO CAUSE FLOODING OR BYPASSING OF THE INLET. DAMAGED OR CLOGGED BAGS SHALL BE REPLACED. A
BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW CAPACITY HAS BEEN REDUCED SO
5. INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT. BAGS SHALL
CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40 SIEVE.
STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDALTEAR STRENGTH OF 50 LBS. FILTER BAGS SHALL BE
4. AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS, A MINIMUM BURST
UNTIL ROADWAY SURFACE RECEIVES FINAL COAT.
MAINTAINED UNTIL ROADWAY IS PAVED. SIX INCH MINIMUM HEIGHT ASPHALT BERM SHALL BE MAINTAINED
3. ROLLED EARTHEN BERM SHALL BE MAINTAINED UNTIL ROADWAY IS STONED. ROAD SUBBASE BERM SHALL BE
SHALL BE REQUIRED FOR ALL INSTALLATIONS.
2. INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR TRAP. BERMS
1. MAXIMUM DRAINAGE AREA = 1/2 ACRE.
NOTES:
MEMBRANE
IMPERVIOUS SANDBAGS
SANDBAG DIVERSION DAM OR COFFERDAM
NTS
2 BAG MINIMUM HEIGHT ABOVE NORMAL BASE FLOW
STREAM
COFFERDAM ALTERNATIVES
CONCRETE BLOCKS
OPTIONAL SANDBAG PLATFORM
NTS
M I
N
* SANDBAG MUST BE TIED
* CLEAN FILL MUST BE USED IN SANDBAG
TO ADDED SEAM
STAGGER BAGS A
1 CY SANDBAG DIKE
A
SECTION A-A
1 CY SANDBAG
(3'-0" X 3'-0")
.0
M
IN
POLYETHYLENE SHEET
MINIMUM 6 MIL
PER AASHTO-M171
LINER IN PLACE
IMPERVIOUS
SANDBAG TO HOLD
BED
STREAM
LINER IN PLACE
SANDBAG TO HOLD IMPERVIOUS
WITH SANDBAGS
STREAM BOTTOM AND SECURED
IMPERVIOUS LINER EXTENDED TO
OPTIONAL SANDBAG PLATFORM
NORMAL STREAM FLOW
SANDBAG
WORK AREA
JERSEY BARRIER
JERSEY BARRIER
BY 3' MIN
SHEET OVERLAP
POLYETHYLENE
BLOCK
CONCRETE
RTF
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
PUMPED WATER FILTER BAG
NTS
MADE FROM WOVEN GEOTEXTILES THAT MEET THE FOLLOWING STANDARDS:
TRAPPING PARTICLES LARGER THAN 150 MICRONS. HIGH VOLUME FILTER BAGS SHALL BE
WITH HIGH STRENGTH, DOUBLE STITCHED "J" TYPE SEAMS. THEY SHALL BE CAPABLE OF
LOW VOLUME FILTER BAGS SHALL BE MADE FROM NON-WOVEN GEOTEXTILE MATERIAL SEWN
AOS% RETAINED
UV RESISTANCE
MULLEN BURST
PUNCTURE
GRAB TENSILE
AVG WIDE WIDTH STRENGTH
PROPERTY
ASTM-D-4751
ASTM-D-4355
ASTM-D-3786
ASTM-D-4833
ASTM-D-4632
ASTM-D-4884
TEST METHOD
80 SIEVE
70%
350 PSI
110 LB
205 LB
60 LB/IN
MINIMUM STANDARD
CEASE IMMEDIATELY AND NOT RESUME UNTIL THE PROBLEM IS CORRECTED.
FILTER BAGS SHALL BE INSPECTED DAILY. IF ANY PROBLEM IS DETECTED, PUMPING SHALL
SCREENED.
BY THE MANUFACTURER, WHICHEVER IS LESS. PUMP INTAKES SHALL BE FLOATING AND
THE PUMPING RATE SHALL BE NO GREATER THAN 750 GPM OR ½ THE MAXIMUM SPECIFIED
RECOMMENDED FOR THIS PURPOSE.
SPECIFIED BY THE MANUFACTURER AND SECURELY CLAMPED. A PIECE OF PVC PIPE IS
THE PUMP DISCHARGE HOSE SHALL BE INSERTED INTO THE BAGS IN THE MANNER
AREA IS NOT AVAILABLE.
WATERSHEDS, WITHIN 50 FEET OF ANY RECEIVING SURFACE WATER OR WHERE GRASSY
BERM OR COMPOST FILTER SOCK SHALL BE INSTALLED BELOW BAGS LOCATED IN HQ OR EV
NO DOWNSLOPE SEDIMENT BARRIER IS REQUIRED FOR MOST INSTALLATIONS. COMPOST
STEEPNESS.
AND NON-POLLUTING MATERIAL MAY BE PLACED UNDER THE BAG TO REDUCE SLOPE
GREATER THAN 5%. FOR SLOPES EXCEEDING 5%, CLEAN ROCK OR OTHER NON-ERODIBLE
STONE TO INCREASE DISCHARGE CAPACITY. BAGS SHALL NOT BE PLACED ON SLOPES
UNDERLAYMENT AND FLOW PATH SHALL BE PROVIDED. BAGS MAY BE PLACED ON FILTER
STABLE, EROSION RESISTANT AREAS. WHERE THIS IS NOT POSSIBLE, A GEOTEXTILE
BAGS SHALL BE LOCATED IN WELL-VEGETATED (GRASSY) AREA, AND DISCHARGE ONTO
REMOVAL UNLESS BAGS COME WITH LIFTING STRAPS ALREADY ATTACHED.
THAT HAVE FAILED OR ARE FILLED. BAGS SHALL BE PLACED ON STRAPS TO FACILITATE
FULL OF SEDIMENT. SPARE BAGS SHALL BE KEPT AVAILABLE FOR REPLACEMENT OF THOSE
PURPOSES SHALL BE PROVIDED. FILTER BAGS SHALL BE REPLACED WHEN THEY BECOME ½
A SUITABLE MEANS OF ACCESSING THE BAG WITH MACHINERY REQUIRED FOR DISPOSAL
7.
6.
5.
4.
3.
2.
1.
NOTES:
FILTER BAG
FILTER BAG
WELL VEGETATED, GRASSY AREA
DISCHARGE HOSE
PUMP
INTAKE HOSE
CLAMPS
(RECOMMENDED)
HEAVY DUTY LIFTING STRAPS
INTAKE HOSE
PUMP
CLAMPS
DISCHARGE HOSE
WELL VEGETATED, GRASSY AREA
PLAN VIEW
ELEVATION VIEW
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\05_ES_DET03.dgn (Default)mmattrazzo 08\03\2022 18:11:48
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
PER ACRE PER 1,000 SF PER 1,000 SY NOTESMULCH TYPE
APPLICATION RATE FOR SLOPES LESS THAN 3:1
1 TON
4-6 TONS
3 TONS
3 TONS
415 LB
1,650-2,500 LB
1,240 LB
1,240 LB
MULCH BLANKET
EROSION CONTROL
HYDROMULCH
WOOD CHIPS
HAY
STRAW
SLOPES 3:1 AND GREATER
MANUFACTURERS' INSTRUCTIONS.
APPLY BLANKET AND ANCHOR PER
47 LB
185-275 LB
140 LB
140 LB
MULCH APPLICATION RATES
SC150 (2:1) OR APPROVED EQUALS
NORTH AMERICAN GREEN S150 (3:1) AND
SEE NOTES.
AND LEGUMES
MAY PREVENT GERMINATION OF GRASSES
OTHER NATIVE FORAGE GRASSES
TIMOTHY, MIXED CLOVER AND TIMOTHY OR
WEEDS, NOT CHOPPED OR FINELY BROKEN
EITHER WHEAT OR OAT STRAW, FREE OF
NOTE:
3. THE APPLICATION RATE FOR ANY HYDROMULCH SHOULD BE 2,000 LB/ACRE AT A MINIMUM.
2. WOOD FIBER HYDROMULCH MAY BE APPLIED ON STEEPER SLOPES PROVIDED A TACKIFIER IS USED.
1. SHREDDED PAPER HYDROMULCH SHOULD NOT BE USED ON SLOPES STEEPER THAN 5%.
SPECIES:
% PURE LIVE SEED:
APPLICATION RATE:
MULCH TYPE:
MULCHING RATE:
ANCHORING METHOD:
SEEDING SEASON DATES:
SPECIES:
% PURE LIVE SEED:
APPLICATION RATE:
MULCH TYPE:
MULCHING RATE:
ANCHOR MATERIAL:
ANCHORING METHOD:
RATE OF ANCHOR MATERIAL APPL:
SEEDING SEASON DATES:
FORMULA D
44.0
Straw
3/15 TO 6/1 & 8/1 TO 10/15
Per Manufacturers' Instructions
Per Manufacturers' Instructions
Per Manufacturers' Instructions
Per Manufacturers' Instructions
LB/1000 SY
LB/1000 SY
LB/1000 SY
LB/1000 SY
TEMPORARY AND PERMANENT STABILIZATION SPECIFICATIONS
FORMULA B
44.0
SPECIES:
% PURE LIVE SEED:
APPLICATION RATE:
FERTILIZER TYPE:
FERTILIZER APPL. RATE:
LIMING RATE:
MULCH TYPE:
MULCHING RATE:
(TEMPORARY) FORMULA E
10.0
Hay
1240 LB/1000 SY
LB/1000 SY
LB/1000 SY
(X-X-X)
LB/1000 SY
SEEDING SEASON DATES: 3/15 TO 10/15
See Table A
See Table A
See Table A
Rolled Erosion Control Product
FORMULA N
LB/1000 SY
(PERMANENT, <3:1 SLOPES)
(PERMANENT, SLOPES/SWALE)
FERTILIZER TYPE:
FERTILIZER APPL. RATE:
LIMING RATE:
2480 LB/1000 SY
LB/1000 SY
(X-X-X)
FERTILIZER TYPE:
FERTILIZER APPL. RATE:
LIMING RATE:
2480 LB/1000 SY
LB/1000 SY
(X-X-X)
ANCHOR MATERIAL:
ANCHORING METHOD:
RATE OF ANCHOR MATERIAL APPL: LB/1000 SY
N/A
N/A
N/A
N/A
10-10-20
10-20-20
10-10-10
10-10-10 FERTILIZER
AGRICULTURAL LIME
10-10-20 FERTILIZER
AGRICULTURAL LIME
TEMPORARY SEEDING APPLICATION RATE
SOIL AMENDMENT PER ACRE
500 LB
1 TON
1,000 LB
6 TONS
PER 1,000 SF PER 1,000 SY
12.5 LB
40 LB
25 LB
240 LB
100 LB
410 LB
210 LB
2,480 LB
NOTES
TOPSOIL STOCKPILES
TYPICALLY NOT REQUIRED FOR
TOPSOIL STOCKPILES
TYPICALLY NOT REQUIRED FOR
REQUIRED IN AGRICULTURAL FIELDS
OR AS PER SOIL TEST; MAY NOT BE
REQUIRED IN AGRICULTURAL FIELDS
OR AS PER SOIL TEST; MAY NOT BE
PERMANENT SEEDING APPLICATION RATE
SOIL AMENDMENT APPLICATION RATES EQUIVALENTS
NOTE:
AMENDMENTS SHOWN IN THE ABOVE TABLE.
1. A COMPOST BLANKET WHICH MEETS THE STANDARDS OF THE MANUAL MAY BE SUBSTITUTED FOR THE SOIL
TABLE B
SCHEDULE OF SEEDING AND SOIL SUPPLEMENT
APPLICATION
- ALL SLOPES 3:1 AND FLATTER,
- ALL SLOPES STEEPER THAN 3:1
B
AND SWALES, DITCHES
SUPPLEMENT FORMULA
SEEDING AND SOIL
D/N
E - TEMPORARY SEEDING
30.0
D: 3/15 TO 6/1 & 8/1 TO 10/15 & N: 3/15 TO 10/15
WSL JAH 6 7
DETAILS
EROSION AND SEDIMENTATION CONTROL
RTF
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
FORMULA B:
SEEDING RATE PER
WEED SEED
MAX. %
GERMINATIONPURITY
MINIMUM %
WEIGHT
FORMULA AND SPECIES
ANNUAL RYEGRASS (LOLIUM MULTIFLORUM)
90ANNUAL RYEGRASS (LOLIUM MULTIFLORUM) 100
TABLE A
EXCEEDING 50% OF THE TOTAL RYEGRASS COMPONENT.
OF IMPROVED CERTIFIED VARIETIES WITH NO ONE VARIETY
PERENNIAL RYEGRASS MIXTURE (LOLIUM PERENNE) A COMBINATION
FORMULA N CONSERVATION MIX:
OX-EYE SUNFLOWER (HELIOPSIS HELIANTHOIDES)
NEW ENGLAND ASTER (SYMPHYOTRICHUM NOVAE-ANGLIE)
BLACK EYED SUSAN (RUDBECKIA HIRTA)
ANNUAL RYEGRASS (LOLIUM MULTIFLORUM)
INDIANGRASS (SORGHASTRUM NUTANS)
VIRGINIA WILD RYE (ELYMUS VIRGINICUS)
CANADA WILD RYE (ELYMUS CANADEIS)
LITTLE BLUESTEM (ANDROPOGON SCOPARIUS)
CREEPING RED FESCUE (FESTUCA RUBRA)(IMPROVED AND CERTIFIED)
50% OF THE TOTAL HARD FESCUE COMPONENT
IMPROVED CERTIFIED VARIETIES WITH NO ONE VARIETY EXCEEDING
HARD FESCUE MIXTURE (FESTUCA LONGIFOLIA).A COMBINATION OF 30
0.10
0.10
0.20
0.20
0.20
0.20
0.10
0.20
0.20
0.20
9.0
9.0
1.2
1.8
1.2
0.9
3.0
1.5
0.9
1.5
30.0 TOTAL
FORMULA E:
EXCEEDING 50% OF THE TOATAL BLUEGRASS COMPONENT.
OF IMPROVED CERTIFIED VARIETIES WITH NO ONE VARIETY
KENTUCKY BLUEGRASS MIXTURE (POA PRATENSIS) A COMBINATION
SSP COMMUTATE) (IMPROVED AND CERTIFIED)
CREEPING RED FESCUE OR CHEWINGS FESCUE (FESTUCA RUBRA OR
0.10
0.10
0.15
LB/1000 SQ YD
8.5
12.5
21.0
44.0 TOTAL
95 0.10 10.0
10.0 TOTAL
FORMULA D CONSERVATION MIX:
TALL FESCUE (FESTUCA ARUNDINACEA VAR. KENTUCKY 31)
SSP COMMUTATE) (IMPROVED AND CERTIFIED)
CREEPING RED FESCUE OR CHEWINGS FESCUE (FESTUCA RUBRA OR
0.10
0.10
0.10
30.0
15.0
5.0
50.0 TOTAL
5 95 0.10 2.0ANNUAL RYEGRASS (LOLIUM MULTIFLORUM) 90
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\06_ES_DET04.dgn (Default)mmattrazzo 08\03\2022 18:11:49
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
30895.11 Y:\Pottsville\30800S\30895.11_Harris_Hill_Road_BR\Eng_Docs\ES\07_ES_PL01.dgn (Default)mmattrazzo 08\03\2022 18:12:03
Sheet No.: OF reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2022, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.: 30895.11
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Kingston Township, Luzerne County, Pennsylvania
CB26305 STRUCTURE REPLACEMENT
OVER TOBY CREEK
HARRIS HILL ROAD (T-783)
8/3/2022
T O
B Y
C R
E E
K
18"
IN01
IN02
OXF
Ps
CP NO 3
MH
20 21 22
CF12
0 2010 FEET
PLAN
EROSION AND SEDIMENTATION CONTROL
DEP STREAM RESTRICTIONS
MF - MIGRATORY FISHES
CWF - COLD WATER FISHERY
TROUT NATURAL REPRODUCTION: 10/1 - 12/31
WSL JAH RTF 7 7
DEVICES (TYP)
TEMPORARY DIVERSION
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE075322
RYAN T. FASNACHT
CHAPTER 93 CLASSIFICATION - TOBY CREEK
CLASS R-4 (TYP)
CHOKED WITH ROCK,
ROCK, CLASS R-8
CLASS R-5
ROCK,
EXISTING STRUCTURE
PROPOSED STRUCTURE
HYDRAULIC OPENING = 380 SF
OUT-TO-OUT WIDTH = 34.0'�
MIN. UNDERCLEARANCE = 24'-0"
CLEAR SPAN = 18.0'�
SKEW = 90°
STACKED STONE AND CONCRETE ARCH CULVERT
HYDRAULIC OPENING = 750 SF
STRUCTURE WIDTH = 37'-4•" OUT-TO-OUT
ROADWAY WIDTH = 34'-0" CURB-TO-CURB
MIN. UNDERCLEARANCE = 21'-7"
SPAN LENGTH = 54'-6" � TO � BRG
SKEW = 90°
PA BULB-TEE BEAM BRIDGE
SINGLE SPAN COMPOSITE P/S CONCRETE
LEGEND
ENTRANCE
CONSTRUCTION
ROCK
R-4 (TYP)
ROCK, CLASS
OTHERS)
RELOCATED BY
(TO BE
OTHERS)
RELOCATED BY
(TO BE
- PUMPED WATER FILTER BAG
- CONCRETE WASHOUT
- 100-YEAR FLOODPLAIN (FEMA)
- 12" COMPOST FILTER SOCK
- LIMIT-OF-DISTURBANCE
- INLET PROTECTION
- ROCK, CLASS AS INDICATED
- TEMPORARY SHORING
- PROPOSED CONTOUR
- EXISTING CONTOUR
- EDGE OF STREAM
- SOIL BOUNDARY
CTCO CS/44
41956
49936-
UGI
UGI 49932-41963
N
S T
R
S U
R V
E
S R
P
B
T
A
A
R R
L
D
P
A
R
G M
E N
T
F S
E T
R
G M
E N
T
F S
E T
R
M E
M O
R I
G H
W A
Y
FOR TOWNSHIP ROAD
RIGHT-OF-WAY LINE
REQUIRED
EASEMENT
TEMPORARY CONSTRUCTION
SURVEY & CONSTR �
HARRIS HILL RD
F
W N
S H
P
A D
L E
G
G H
T
O F
W
N E
HARRIS HILL ROAD
H E
L L
E
G
O V
A D
METER POLE
BEGIN FULL DEPTH PVMT
STA 20+00.00, 12.26'RT
STA 20+43.17
BEGIN STRUCTURE
END FULL DEPTH PVMT
STA 20+99.33
BEGIN FULL DEPTH PVMT
END STRUCTURE
STA 21+79.00
END FULL DEPTH PVMT
MAP #35 F8S5-2-4A
TRAILS ASSOCIATION
ANTHRACITE SCENIC
B A
K
M
U N
T A
N
A I
L
MAP #35 F8S4-5-3A
TRAILS ASSOCIATION
ANTHRACITE SCENIC
MAP #35 F9S3-4-1
AUTHORITY
GENERAL STATE
KEITH A. HUNTER
THERMOPLASTIC PIPES
FOUR (4) TEMPORARY 18"
G H
T
O F
W A
Y
L E
G A
L
ROAD
TOWNSHIP
FOR
LINE
RIGHT-OF-WAY
LEGAL
ROAD
FOR TOWNSHIP
LINE
RIGHT-OF-WAY
LEGAL
EASEMENT
TEMPORARY CONSTRUCTION
L I
G H T
O F
W
G
ROAD
TOWNSHIP
LINE FOR
RIGHT-OF-WAY
REQUIRED
EASEMENT
DRAINAGE
REQUIRED
| 01_ES_GenNotes |
| 02_ES_NOTES |
| 03_ES_DET01 |
| 04_ES_DET02 |
| 05_ES_DET03 |
| 06_ES_DET04 |
| 07_ES_PL01 |
File details come from the government source that posted it. Updated .