7-03. Attachment C - Scope of Work- ATC.docx
DOCX document 3 MB Posted
- Attached to
- UDOT RFP- NEMA Signal Cabinets
- Solicitation number
- UDOT260266MP
- Issued by
- Utah
About this file
Summary
This is a Detailed Scope of Work and Requirements document for Advanced Traffic Signal Controller (ATC) Cabinet assemblies issued by the Utah Department of Transportation (UDOT). The document specifies minimum requirements for ATC High-Voltage (HV) cabinet assemblies manufactured to meet the ATC 5301 Standard Publication v02.02 (dated March 18, 2019 or most recent version). UDOT seeks standard cabinets incorporating traditionally required items for typical signalized intersections, with auxiliary devices and optional items available as individual bid items to expand cabinet capability for large or unusual intersection designs. The cabinet assemblies must be modular, completely removable and installable without removing other equipment, and capable of flash signal operation. Standard cabinet dimensions are 67" H x 44" W x 26" D, constructed with 0.125-inch minimum thickness aluminum sheet, featuring dual front and rear doors with overlapping design, rainproof housing with crowned top, dual fan ventilation, LED cabinet lighting, and dual EIA rack cages. The specification includes detailed requirements for 16-channel and 32-channel output configurations with corresponding field output termination assemblies, 24-channel and 48-channel input configurations with field input termination assemblies, service assemblies, communication and power bus systems, and specified component models including High-Density Switch Pack/Flasher Units, Cabinet Monitor Units, Serial Interface Units, Auxiliary Display Units, flash transfer relays, and cabinet power supplies.
The cabinet must meet comprehensive electrical, environmental, and testing requirements including operation across applied line voltages of 90 to 135 Vac, frequencies of 60 Hz (±3.0), humidity levels of 5% to 95%, and ambient temperatures ranging from -34.6°F to +165.2°F. Equipment must comply with UL Bulletin of Research No. 23 for rain tests, withstand power line surge protection testing, and maintain normal operation during temperature cycling and humidity extremes. Manufacturers must have minimum 10+ years of ATC Cabinet manufacturing experience, trained and qualified field technicians, and CTPAT compliance with active employee training programs. All cabinets include weatherproof wiring diagrams, and a complete Quality Control/final test report signed by a responsible manager must accompany each unit. The warranty covers a minimum one-year period from delivery date, with the vendor responsible for defect corrections at no cost to UDOT, including all shipping costs and on-site technical services associated with repairs or component replacements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-07. Submittal Form- Attachment A- Standard Terms and Conditions- Yes No.docx | DOCX document | |
| 4-09. Sample Score Sheet- NEMA TS 2.doc | DOC document | |
| 3-06. Submittal Form- Business Confidentiality- Yes No.doc | DOC document | |
| 8-05. Submittal Form- Vendor Setup Form.pdf | ||
| 9-01. RFP General Information.doc | DOC document | |
| 10-09. Sample Score Sheet- ATC.doc | DOC document | |
| 6-02. Attachment B - Scope of Work- NEMA TS 2.docx | DOCX document | |
| 1-04. Submittal Form- Attachment D - Cost Proposal.xlsx | XLSX spreadsheet | |
| 5-08. Submittal Form- Certifications- Yes No.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT C
DETAILED SCOPE OF WORK AND REQUIREMENTS
ADVANCED TRAFFIC SIGNAL CONTROLLER CABINET
1.0 Information
Utah Department of Transportation (UDOT) is to be provided Advance Traffic Controller (ATC) cabinet assemblies for operation of signalized intersections throughout the state.
UDOT’s standard cabinets will include traditionally incorporated items in a typical and practical number as required for the majority of signalized intersections. However, these auxiliary devices, as well as other optional items identified throughout this Detailed Scope of Work and Requirements, will also be listed as individual bid items for purchase, which will allow UDOT to expand cabinet capability for the needs of large or unusual intersection designs.
2.0 General Requirements
General Introduction This specification sets forth the minimum requirements for Advance Traffic Controller Cabinets (ATCC) High-Voltage (HV). The cabinet assembly shall meet, as a minimum, all sections of the ATC 5301 Standard Publication No. v02.02 dated March 18, 2019, or the most recent version. The manufacturer shall have a minimum of 10+ years of manufacturing ATC Cabinets, trained and qualified field technicians to support the ATC Cabinet technology. Additionally, the manufacturer shall have compliance with Customs Trade Partnership Against Terrorism (CTPAT), with active and ongoing/ continuing employee training as part of the manufacturing processes for critical and secure transportation infrastructure equipment and UL Bulletin of Research No. 23, "Rain Tests of Electrical Equipment."
Where differences occur, this specification shall govern.
General ATCC Description and Requirements ATCC are built to meet the ATC 5301 v02.02 Advanced Transportation Controller Cabinet Standard (ATCC). The ATCC uses high-speed serial communications, providing modern features such as simplified wiring, cabinet space availability and more. Including benefits such as advanced diagnostics, enhanced safety, and long-term true cost of ownership as a sound investment for any agency. The ATCC supports both 120VAC and 48VDC LED signals, while high-density switch packs and quad detector modules allow for up to 32 channel signal outputs, and 120 detector inputs. The ATCC provides both voltage and current monitoring of all signal outputs, including ultra-low power LEDs.
This specification describes the 120VAC High-Voltage ATCC. The ATCC family is a modular, serial interconnected cabinet architecture that is designed to fulfill a variety of transportation applications.
In addition the Cabinet shall adhere to the following requirements:
· The assemblies shall be completely removable from or installable in the cabinet without removing any other equipment and using only a standard slotted or Phillips screwdriver.
· The cabinet shall be capable of Cabinet Flash signal operation in the absence of any of the following assemblies: Input Assembly, Output Assembly, and Controller.
· A momentary push button switch shall be provided that, when pressed, energizes the 24 Vdc to the HDSPs during Flash Mode. The button shall be labeled “24 VDC BYPASS” and shall be located on the front of the Output Assembly.
· High-voltage components (over 50 V) shall be protected from incidental contact per NEC.
· All circuit breakers, switches (except police panel switches) and indicators shall be readily visible and accessible from the area accessed by opening the front door.
· All circuit breakers shall have covers to prevent accidental tripping.
· All Assemblies shall be modular with pluggable cabling.
· The ventilation fans shall be fastened to the cabinet via two thumb screws and shall not be fastened in a manner that requires any tools for removal or installation.
· Door switches shall be powered by 48 Vdc.
· Wire raceway shall be integrated as part of the cabinet allowing for neat internal and field wiring.
· All equipment in the cabinet shall be clearly and permanently labeled.
· The marker strips shall be made of material that can be easily and legibly written on using a pencil or ballpoint pen. Marker strips shall be located immediately below the item they are to identify and must be clearly visible with the items installed.
· Guides (top and bottom) shall be provided for assembly plug-in units. The guides shall begin 0.50 inch from the assembly front panel face.
General ATCC Configuration The ATCC shall include Service Assembly (SA), Input Assembly (IA), Output Assembly (OA), Communication and Power Bus Assembly, Field Input Termination Assembly (FITA), and Field Output Termination Assembly (FOTA).
The ATCC configuration shall include the following:
· Cabinet housing defined by the ATC 5301 Standard
· Corbin #2 door locks
· Cabinet ventilation consists of dual fan panel assembly and air filter
· Cabinet lighting
· Cabinet finish
· EIA cabinet cage – 2ea
· Drawer shelf
· Communication and Power Bus Assembly
· 16 or 32 channel output assembly
· 16 channel field output termination assembly
· 24 or 48 channel input assembly
· 24 or 48 channel field input termination assembly
· Service assembly w/ main surge arrestor
· Auxilliary display unit
· ATCC power supply
· External generator plug with automatic transfer relay for generator
· Include internal outlet for optional power station that isolates the external generator outlet when being used
· Include a 120V cord for the cabinet controller
· Include controller power cable
· Include heavy duty shelves for equipment
· Auxilliary IO panel
· Include SDLC bus (spring latches) and 4qty SDLC cables with metal housing. SDLC cables to be routed as follows with 1 foot slack to accommodate connecting to equipment (1 cable to front left top half depth shelf, 2 cables to front right top full depth shelf, and 1 cable to front right middle half depth shelf). Provide cable from the DC power out panel to the SDLC bus.
· Rubber boots on the bottom of cabinet for cable protection
· Include bracket for mounting power inverter
· Move field wiring panels to front side of cabinet
· Provide 1 inch spacing on rack equipment for cooling
· Use push click Phoenix connectors
· 2 ped isolator cards
Provide cost for an optional vendor installed UPS system bypass switch.
The following plug-in devices shall be provided for a 16-channel Output Assembly:
· 8qty High Density Switch Packs (HDSP)
· 1qty Cabinet Monitor Unit (CMU)
· 1qty Serial Interface Units (SIU)
The following plug-in devices shall be provided for a 32-channel Output Assembly:
· 16qty High Density Switch Packs (HDSP)
· 1qty Cabinet Monitor Unit (CMU)
· 2qty Serial Interface Units (SIU)
The following plug-in devices shall be provided for a Field Output Termination Assembly:
· 8qty High Density Flash Transfer Relays (HDFTR)
· 8qty High Density Output Suppressors
The following plug-in devices shall be provided for a 24-channel Input Assembly:
· 1qty Serial Interface Units (SIU)
· 1qty Dual Channel DC Isolator Cards (242L)
The following plug-in devices shall be provided for a 48-channel Input Assembly:
· 2qty Serial Interface Units (SIU)
· 1qty 4-Channel DC Isolator Cards (244L)
The following plug-in devices shall be provided for a 24-channel Field Input Termination Assembly:
· 12qty High Density Input Suppressors
The following plug-in devices shall be provided for a 48-channel Field Input Termination Assembly:
· 24qty High Density Input Suppressors
The following plug-in devices shall be provided with a service assembly:
· 2qty High Density Flasher Units (HDFU) Cabinet Suppressor-Filter
3.0 Cabinet Assembly
3.1 Cabinet Housing
· Enclusure The housings shall include, but not be limited to, the following: Enclosure, Doors, Gasketing, Lifting Eyes & External Bolt Heads, Latches & Locks, Ventilation, Hinges and Door Catches, Police Panel and Cage Supports and Mounting.
· Housing Construction The housing shall be rainproof. It shall have two front and two rear doors, The doors shall overlap requiring one lock and one handle on front and back doors. Enclosure top shall be crowned to prevent standing water. The cabinet shall be: 67” H x 44” W x 26” D (rounded to the nearest inch).
· Material Thickness The enclosure, doors, lifting eyes, gasket channels, police panel door, spacer supports, and all supports welded to the enclosure and doors shall be fabricated of 0.125-inch minimum thickness aluminum sheet. The filter shell, filter trough, fan support and police panel enclosure shall be fabricated of 0.080-inch minimum thickness aluminum sheet. The spacer supports shall have the option to use 0.059-inch minimum stainless-steel sheet.
· Welds All exterior seams for enclosure and doors shall be continuously welded and shall be smooth. All edges shall be filled to a radius of 0.03125 inch minimum. Exterior cabinet welds shall be done by gas Tungsten arc TIG process only. ER5356 aluminum alloy bare welding electrodes conforming to AWS A5.10 requirements shall be used for welding on aluminum. Procedures, welders, and welding operators shall conform to the requirements and practices in AWS B3.0 and C5.6 for aluminum. Internal cabinet welds shall be done by gas metal arc MIG or gas Tungsten arc TIG process.
· Aluminum Surface Protection & Anti-Graffiti Paint If Anti-Graffiti Paint is requested, each stage in the process shall be as follows:
· Perform treatment with a moderately acidic, liquid cleaner concentrate for thorough cleaning.
· Clean water rinse from reverse osmosis system (< 2500 PPM).
· Clean water rinse from reverse osmosis system (< 500 PPM).
· Apply a conversion coating to form an excellent base for bonding powder to parts and producing good resistance to corrosion.
· Clean water rinse from reverse osmosis system (< 800 PPM).
· Clean water rinse from reverse osmosis system to decrease any solids on surfaces (< 100 PPM).
· Final seal rinse to enhance corrosion resistance.
Convey through a dry-off oven at a cycle of 10 to 20 minutes at 380º F. This eliminates any trapped water and gases in the parts.
Apply polyester dry powder at 90,000 volts for maximum mil transfer. Thickness of the powder coating shall nominally be 2 to 5 mils.
Convey into the cure oven for a thermal setting [cure] cycle of 10 to 20 minutes at 380 - 425º F.
The agency, at its option, may require the winning the Vendor to submit written certification of compliance to the requirements listed in this section of the specification.
· Enclosure Door Frames and Door Seals The enclosure door frames shall be double flanged out on all four sides and shall have strikers to hold tension on, and to form a firm seal between, the door gasketing and the frame. The dimension between the door edge and the enclosure external surface when the door is closed and locked shall be 0.156 inch (+/-0.08 inches).
· Gasketing Gasketing shall be provided on all door openings and shall be dust tight. Gaskets shall be 0.25 inches minimum thickness closed cell neoprene or silicone (BOYD R- 108480 or approved equal) and shall be permanently bonded to the metal. A gasket top and side channels shall be provided to support the top gasket on the door to prevent gasket gravitational fatigue.
· Lifting Eyes and Exterior Bolt Heads The housing shall be provided with two lifting eyes for placing the cabinet on its foundation. Each eye opening shall have a minimum diameter of 0.75 inch. Each eye shall be able to support the weight load of 1000 lbs. All bolt heads shall be tamperproof type.
· Latching Handles The latching handles shall have provision for padlocking in the closed position. Each handle shall be 0.75 in minimum diameter stainless steel with a minimum 0.5 in shank. The padlocking attachment shall be placed at 4.0 in from the handle shank center to clear the lock and key. An additional 4.0 in minimum gripping length shall be provided.
· Latching Mechanism The latching mechanism shall be a three-point draw roller type. The pushrods shall be turned edgewise at the outward supports and have a cross section of 0.25 in thick by 0.75 in wide, minimum.
· Locks and Handles When the door is closed and latched, the door shall be locked. The lock and lock support shall be rigidly mounted on the door. In the locked position, the bolt throw shall extend a minimum of 0.25 ± 0.03125 in into the latch cam area. A seal shall be provided to prevent dust or water entry through the lock opening.
· Locks The locks shall be Corbin #2 type or approved equal. One key shall be supplied with each lock. The keys shall be removable in the locked position only.
· Bolts The locks shall have rectangular, spring-loaded bolts. The bolts shall have a 0.281 in throw and shall be 0.75 inch wide by 0.75 inch thick (tolerance is ±0.035 in).
· Center Latch Cam The center latch cam shall be fabricated of a minimum thickness 0.1875-inch steel or aluminum. The bolt surface shall horizontally cover the cam thickness. The cam shall be structured to only allow the door to open when the handle is moved toward the center of the door.
· Rollers Rollers shall have a minimum diameter of 0.875 inch with nylon wheels and steel ball bearings.
· Hinges Stainless steel hinges (two bolts per leaf) shall be provided to bolt the enclosure to the doors.
Each door shall have four hinges per door. Each hinge shall be 3.5-inch minimum length and have a fixed pin. The pin ends shall be welded to hinge and ground smooth. The pins and bolts shall be covered by the door edge and not accessible when the door is closed. A ground strap between the door and the main cabinet housing shall be required when 120 Vac devices are mounted on the door.
· Door Catches Front and rear doors shall be provided with catches to hold the door open at both 90 and 165 (±10) degrees. The catch minimum diameter shall be 0.375-inch aluminum rods. The catches must be capable of holding the door open at 90 degrees in a 60-mph wind acting at an angle perpendicular to the plane of the door.
· Police Panel A police panel assembly shall be provided to allow limited control access. The panel door shall be equipped with a lock and master police key. The front and back of the panel shall be enclosed with a rigid metal covering so that no parts having live voltage are exposed. The panel assembly shall have a drain to prevent water from collecting within the assembly. The drain shall be channeled to the outside. The cabinet shall have one switch provided and labeled "SIGNALS ON / OFF” and one switch provided and labeled "FLASH / AUTO". The MANUAL CONTROL ENABLE ON / OFF switch and a receptacle for the INTERVAL ADVANCE cord shall be provided. An INTERVAL ADVANCE cord, six feet in length, shall be provided.
3.2 Rack Cage
Two standard rack cages shall be installed inside the housing for mounting of the ATC Cabinet assemblies. The EIA rack portion of the cage shall consist of four continuous, adjustable equipment mounting angles. The mounting angle nominal thickness shall be 11- gauge plated steel. The mounting angles shall be tapped with 10-32 threads with EIA universal spacing. The mounting angle shall comply with standard EIA-310-B and shall be supported at the top and bottom by either welded or bolted support angles to form a cage. The mounting angles shall provide holes to mount the side panels.
· Cage Connection The cage shall be bolted to the cabinet at four points via the housing cage supports and four points via associated spacer brackets (top and bottom).
· Cage Location The cage shall be centered within the cabinet door opening(s).
· Cage Mounting Supports Cage mounting supports shall be provided on either side, level with the bottom edge of the door opening, for horizontal support and bolt attachment; side cage supports provided for the bracket cage supports; and bracket cage support attachments.
· Clearance between Rails Clearance between rails for mounting assemblies shall be 17.75 inch.
3.3 Housing Ventilation
Housing ventilation shall include intake, exhaust, fans, and thermostat.
· Intake The louvered vent depth shall be a maximum of 0.25 inch.
· Fans Each electric fan shall be equipped with ball or roller bearings and shall have a minimum capacity of 100 cubic feet of free air delivery per minute. Two or four DC powered fans shall be mounted within the housing and protected with a finger guard. A Fan Test switch shall be provided.
· Temperature Controlling The fans shall be thermostatically controlled and shall be manually adjustable to turn on between 32 Fahrenheit and 140 Fahrenheit with a differential of not more than 20 Fahrenheit between automatic turn on and off. The fan circuit shall be protected at 125% of the fan motor ampacity. The manual adjustment shall be graded in 20 Fahrenheit increment scale. The Thermostats shall be an Omega KT01101141900 or approved equal.
3.4 Cabinet Lights
The cabinet shall be equipped with four LED lights activated by door switches and equipped with fuses.
5.0 ATCC Assemblies
4.1 Output Assembly (16-Channel)
The Output Assembly shall be a 3U high rack mounted assembly. The Output Assembly shall house eight Model 2202-HV High-Density Switch Pack / Flasher Units (HDSP/FU) and shall provide 48 output circuits.
The Output Assembly shall accommodate one Model 2218 Serial Interface Unit (SIU) to provide interface and control via system SB1/SB2.
The Output Assembly shall house one model 2212-HV Cabinet Monitor Unit (CMU), the Main Contactor, Stop Time Switch, Flash / Auto Switch, one Circuit Breakers and Momentary 24 Vdc Bypass Switch. The Main Contactor shall be located at the back of the Output Assembly access door. Circuit breakers and toggle switches shall be equipped with a guard. Each 16ch Output Assembly shall be coupled with a field output termination assembly.
4.2 Output Assembly (32-Channel)
The Output Assembly shall be a 6U high rack mounted assembly. The Output Assembly shall house sixteen Model 2202-HV High-Density Switch Pack / Flasher Units (HDSP/FU) and shall provide 96 output circuits.
The Output Assembly shall accommodate two Model 2218 Serial Interface Unit (SIU) to provide interface and control via system SB1/SB2.
The Output Assembly shall house one model 2212-HV Cabinet Monitor Unit (CMU), the Main Contactor, Stop Time Switch, Flash / Auto Switch, two Circuit Breakers and Momentary 24 Vdc Bypass Switch. The Main Contactor shall be located at the back of the Output Assembly access door. Circuit breakers and toggle switches shall be equipped with a guard. Each 32ch Output Assembly shall be coupled with two field output termination assemblies.
4.3 Field Output Termination Assembly
Each Field Output Termination Assembly (FOTA) shall be coupled with either the 16ch or 32ch Output Assembly and shall house eight Model 21XBXHL-48VDC High-Density Flash Transfer Relays (HDFTR). The HDFTRs and Flash Program Blocks (FPB) shall be provided to control and select the color (red, yellow, or dark) during ATC (HV) Cabinet flash mode. HDSP Suppressors shall be provided at the field terminals for the protection of the HDSP. Each HDFTR position shall be labeled with the number of its associated HDSP (1-16). Each FPB position shall be labeled with the number of its associated channel (1-16).
The FOTA shall be provided with 16qty 6-position Phoenix Contact terminal block model number 18-04-94-6 plugs and 18-61-19-6 sockets or approved equal. Each Load Terminal Block receptacle shall be labeled with the number of its associated channel (1-16). Additional labels shall be provided to clearly indicate which terminals correspond to the red, yellow, and green switch pack outputs. The color of these labels shall match the color of their associated output (red, yellow, or green).
The FOTA shall be equipped with an AC- copper bus. The bus shall have 21 positions and shall manage #8 wire.
The FOTA shall be equipped with 48 Eaton Bussmann series GDA fast acting 1A and 250 Vac fuses or approved equal and 48 WERI PART NO: 696 108 003 002 fuse holder or approved equal. The fuses and fuse holders shall be in the back of FOTA. An engraved label panel shall be provided to prevent accidental contact with FOTA PCB. Each fuse holder shall be labeled with its respective R/Y/G color and its respective Channel number.
Each FOTA shall be mounted across the EIA rails, and it shall swing down to provide access to the fuses and HDSP Suppressors.
The FOTA shall include a fused output.
4.4 Input Assembly 24-Channel
The Input Assembly shall be a 3U high rack mounted assembly providing twelve slots of 22/44 pin PCB sockets. One Model 2218-MC Serial Interface Unit (SIU) shall be provided and mated to a DIN 96-pin connector. The SIU shall provide interface and control between the Controller and the input devices via system SB1/SB2. The Input Assembly shall house either 2-channel or 4-channel detection modules. The Input Assembly shall house twelve 2-channel detection modules, or six 4-channel detection modules, or a combination of 2 & 4 channel detection modules up to 24 channels. Each Input Assembly shall be equipped with an Opto Input Card. The Opto Input Card shall be equipped with four LED indicators and four toggle switches. Activation of the switch 1-4 shall place a call into SIU Opto 1-4 input, respectively.
4.5 Input Assembly 48-Channel
The Input Assembly shall be a 3U high rack mounted assembly providing twelve slots of 22/44 pin PCB sockets. Two Model 2218-MC Serial Interface Unit (SIU) shall be provided and mated to a DIN 96-pin connector. The SIU shall provide interface and control between the Controller and the input devices via system SB1/SB2. The Input Assembly shall house either 2-channel or 4-channel detection modules. The Input Assembly shall house twelve 2 or 4-channel detection modules, or a combination of 2 & 4 channel detection modules up to 48 channels
4.6 Field Input Termination Assembly 24-Channel
Each 24-Channel Field Input Termination Assembly shall be coupled with each 24-Channel Input Assembly and shall have positions for landing 24qty, two-wire inputs and their associated earth ground wires. The Field Input Termination Assembly shall have positions for 12 Detection Module Suppressors. The Detection Module Suppressors shall be supplied with the cabinet if procurement requires. The 24-Channel Field Input Termination Assembly shall be mounted across the EIA rails, and it shall swing down to provide access to the back of the assemblies mounted in the opposite side.
4.7 Field Input Termination Assembly 48-channel
Each 48-Channel Field Input Termination Assembly shall be coupled with two 24-Channel Input Assembly or one 48-Channel Input assembly and shall have terminal positions for landing 48qty, two-wire inputs and their associated earth ground wires. The 24-Channel Field Input Termination Assembly shall be mounted across the EIA rails, and it shall swing down to provide access to the back of the assemblies mounted in the opposite side.
4.8 Service Assembly for 16ch output application
The Service Assembly shall be a 3U high rack mounted assembly. It shall house: 1qty Model 2202-HV High-Density Switch Pack / Flasher Units (HDSP/FU), Cabinet Suppressor-Filter, 7-position utility and BBS landing wire terminal, GFCI with Type A/C USB connection, one convenience outlet NEMA 5-15 format, one convenience outlet NEMA 6-15 format, 8qty HDFU output fuses, 4qty HDFU spare fuses, five Circuit Breakers, and a Raw AC+ and AC- terminal block having 4 screw terminals (Phoenix Contact 0710196 & 1778001 or equal). Circuit breakers shall be equipped with guards.
4.9 Service Assembly for 32ch output application
The Service Assembly shall be a 3U high rack mounted assembly. It shall house: 2qty Model 2202-HV High-Density Switch Pack / Flasher Units (HDSP/FU), Cabinet Suppressor-Filter, 7-position utility, and BBS landing wire terminal, GFCI with Type A/C USB connection, one convenience outlet NEMA 5-15 format, one convenience outlet NEMA 6-15 format, 8qty HDFU output fuses, 4qty HDFU spare fuses, five Circuit Breakers, and a Raw AC+ and AC- terminal block having 4 screw terminals (Phoenix Contact 0710196 & 1778001 or equal). Circuit breakers shall be equipped with guards.
4.10 Communication and Power Bus
Communication and Power Bus shall include eight DB25 d-submodular socket connectors to interconnect the SB1/SB2 communication ports of the assemblies and Controller. It shall include an internal termination circuit at the end of the connections (S8) to prevent radio frequency signal reflection. It shall include one Phoenix Contact plug block or approved equal to bring the DC power to the Bus; such power shall be distributed to the ATC (HV) Cabinet Assemblies through seven Phoenix Contact receptacle blocks or approved equal. The copper traces for the DC voltages shall support at least 10 Amp.
The Communication and Power Bus shall be mounted across the EIA rails, and it shall swing down to provide access to the back of the assemblies mounted in the opposite side.
4.11 Drawer Shelf Unit
A telescopic slide out drawer to storage document shall be provided. The Drawer Shelf Unit shall be mounted across the EIA rails and shall have a non-conductive top, locking provision, and pulling handle or lip.
5.0 ATCC Components
5.1 Model 2202-HV-MC High-Density Switch Pack/ Flasher Unit (HDSP-FU) The HDSP-FU shall be compact, pluggable, modular PCB-based, and equipped with DIN connector. The HDSP-FU shall be compatible with ultra-low power LED signal heads, and it shall have a current monitoring feature for each output of each channel. The HDSP-FU shall use real-time standardized high speed SB3 communications with the Cabinet Monitor Unit to send a complete set of RMS voltage and load current measurements. The HDSP-FU shall be 4.5” H x 6.5” D and shall be equipped with a handle, reset push button switch, six RYG LED indictors, four flasher LED indicators, one power LED indicator and two Rx/Tx LED indicators.
The HDSP-FU can function as either a switch pack (HDSP) or as a flasher unit (HDFU).
When installed in the Output Assembly, the High-Density Switch Pack (HDSP) shall provide two RYG channels of operation (6 outputs).
When installed in the Service Assembly, the High-Density Flasher Unit (HDFU) shall function as a four-output flasher.
5.2 Model 2212-HV-MC Cabinet Monitor Unit (CMU)
The Cabinet Monitor Unit (CMU) shall be compact, pluggable, and modular. The CMU shall use real-time standardized 614.4 Kbs SDLC communications with the ATC to transfer command and response data on Serial Bus #1 (SB1). The CMU shall be capable of monitoring up to 32 physical switch pack channels (RYG) and shall have optional four virtual channels. The CMU shall provide a Flasher Alarm feature. The CMU shall analyze the ATC output commands and field input status to isolate the failure source by channel and color. The CMU configuration programming shall be provided by an interchangeable Datakey nonvolatile memory device. This rugged key shall store all CMU configuration parameters and shall eliminate programming using jumpers, diodes, or DIP switches. The CMU shall maintain a nonvolatile event log recording the complete intersection status as well as time stamped previous fault events, 48VDC line events, configuration changes, monitor resets, cabinet temperature and true RMS voltages and currents for all field inputs. The signal sequence history log stored in nonvolatile memory graphically shall display up to 30 seconds of signal status prior to the fault trigger event with 50 ms resolution to ease diagnosing of intermittent and transient faults.
5.3 Model 2218-MC Serial Interface Unit (SIU)
The Model 2218-MC Serial Interface Unit (SIU) shall be a compact, pluggable, and modular.
The SIU shall use real-time standardized 614.4 Kbs SDLC communications with the ATC to transfer command and response data on Serial Bus #1 (SB1). The SIU shall be equipped with 54 programmable input/out pins, four optically isolated input pins, one line sync reference input pin and 4 address select input pins. The optically isolated inputs shall work with either 12 Vac or 24 Vdc. The SIU outputs shall be rated at 150 mA continuous sink current. Each output shall provide a 500-mA typical current limit and shall be rated to 50 V and utilize a voltage clamp for inductive transient protection. The SIU shall be equipped with a front panel LED indicator that can report the current SIU assembly address assignment of the SIU for cabinet configuration verification.
5.4 Model 2220-MC Auxiliary Display Unit (ADU)
The ADU shall install in a 1U height 19” rack space and shall provide a menu driven user interface to the enhanced features of the CMU monitor including the built-in Diagnostic Wizard. The ADU shall provide 32 channels of Red, Yellow and Green LED indicators that display full intersection status and 32 Blue fault status LED indicators shall identify faulty channels. The ADU shall provide proper electrical termination to SB3. The ADU shall have a 4 line by 20-character menu driven liquid crystal display with backlight and heater. The ADU built-in Diagnostic Wizard shall automatically pinpoint faulty signals and offers trouble-shooting guidance and automatically isolate and identify problems. The ADU shall be equipped with Event Logging displaying the CMU time-stamped nonvolatile event log records with the complete intersection status as well as AC Line events, monitor resets, temperature and true RMS voltages and currents.
5.5 Monitor Key Programming Tool (optional)
The Programming Tool provides the capability to Read and Write data from the CMU Datakey device. The software shall be compatible with the CMU-2212-HV-MC
5.6 Model 21XBXHL-48VDC High-Density Flash Transfer Relay (HDFTR) The HDFTR shall have a hermetically sealed cover and shall be moisture proof. The HDFTR shall be filled with dry nitrogen to protect contacts from corrosion and to prevent condensation. The HDFTR shall have a shock/impact resistant metal can cover with solid and bend proof pins. The HDFTR contacts shall be rated at 120 Vac @ 5 Amp. The coil of the HDFTR shall be rated at 48 Vdc. The HDFTR shall have an LED indicator to display contact transfer position.
5.7 Main Contactor (MC)
The MC shall be mercury free and shall be rated at 48 Vdc. The coil of the MC shall be rated at 48 Vdc. The MC shall be equipped with input indicator and shall have SPST- N.O. contacts. The MC shall be placed on a removable panel for maintenance access.
5.8 Cabinet Suppressor-Filter
The cabinet shall be equipped with a Cabinet Suppressor–Filter. The unit shall incorporate the use of warning and failure indicators and shall have a dry relay contact remote sensing circuit. The unit shall be modular and pluggable with a 6-position Beau 5406 connector. The unit shall be rated at continuous service current of 15 Amp and maximum clamp voltage of 390 Vac. The unit dimensions shall be 3.5” H x 3.5” W x 2.8” D.
5.9 High Density Output Suppressors
The HDSP Suppressor shall be modular and pluggable. The unit shall be epoxy encapsulated and equipped with 9-position 5.08 mm Phoenix Contact connector or approved equal. The unit shall be able to protect 6 circuits. The device operating voltage shall be 120 Vac and clamping voltage shall be 340 Vac. The unit dimensions shall be 2” H x 0.7” W x 2” D.
5.10 Model PS-2216-24 Cabinet Power Supply (CPS)
The CPS shall install in a 1U height 19” rack space. The CPS shall be rated at 168 Watts, 48 Vdc @ 1 Amp and 24 Vdc @ 5 Amp.
The CPS shall use modern switching technology and provides full output regulation across changes in AC Line voltage and output load over the full operating temperature range of -34C to +74C without the need for a fan. Power Factor Correction shall be provided.
The CPS shall have separate LED indicators that display AC input status, DC output status and associated fuse integrity. The CPS outputs shall be fused for over-current protection and shall be protected against voltage transient suppressor.
6.0 Cabinet Layout
Cabinet components and shelving to be laid out as follows with dimensions measured from the bottom of the mounting cage. These are initial installation locations and are subject to change if needed to accommodate equipment in the cabinet.
350- 16 channels:
· Front Left Side when facing front of cabinet
· AC Termination Panel mounted at 15 ½” to top of bracket
· Drawer mounted at 17 ¾” to top of bracket
· Load Switch SMU MMU panel mounted at 23” to top of bracket
· Ped Isolator SIU mounted at 29 ½” to top of bracket
· Half Depth Shelf mounted directly above Ped Isolator SIU
· ADU Fault Monitoring Unit mounted at 41 ¾” to top of bracket
· Front Right Side when facing front of cabinet
· ATCC HV Service assembly mounted at 6 ⅛” to top of bracket
· Full depth shelf mounted at 15 3/8” to top of shelf (shelf must accommodate UPS with width of 17 ¼”)
· Half depth shelf mounted at 24 ⅛” to top of shelf
· Full depth shelf mounted at 34 ⅛” to top of shelf
· Back Left Side when facing back of cabinet
· 7” deep 5” tall DIN rail rack mounted at 27 5/8” to top of bracket
· Thermostat mounted to upper right corner of mounting cage
· Back Right Side when facing back of cabinet
· Power Cabinet supply mounted at 41 ¾” to top of bracket
· DC Power Out mounted at 38 ⅛” to top of bracket
· 7” deep 5” tall DIN rail rack mounted at 27 5/8” to top of bracket
· ATCC Field Input mounted at 19 ¾” to top of bracket
350- 32 channels:
· Front Left Side when facing front of cabinet
· AC Termination Panel 1-16ch mounted at 15 ½” to top of bracket
· AC Termination Panel 17-32ch mounted at 23 ¾” to top of bracket
· Drawer mounted at 26” to top of bracket
· Load Switch SMU MMU panel mounted at 36 ½” to top of bracket
· Ped Isolator SIU mounted at 42.9” to top of bracket
· Half Depth Shelf mounted directly above Ped Isolator SIU
· Model 2220-MC Auxiliary Display Unit (ADU) mounted at top of mounting cage
· Move left front LED to top of cabinet mounted under police box to facilitate reading of fault monitoring unit due to brightness of LED lights.
· Front Right Side when facing front of cabinet
· ATCC HV Service assembly mounted at 6 ⅛” to top of bracket
· Full depth shelf mounted at 15 3/8” to top of shelf (shelf must accommodate UPS with width of 17 ¼”)
· Half depth shelf mounted at 27 ¾” to top of shelf
· Full depth shelf mounted at 40” to top of shelf
· Back Left Side when facing back of cabinet
· 7” deep 5” tall DIN rail rack mounted at 34” to top of bracket
· Thermostat mounted to upper right corner of mounting cage
· Back Right Side when facing back of cabinet
· Power Cabinet supply mounted at to top of cage
· DC Power Out mounted at 46 ½” to top of bracket
· 7” deep 5” tall DIN rail rack mounted at 34” to top of bracket
· ATCC Field Input mounted at 25.9” to top of bracket
7.0 ATCC Electrical, Environmental and Testing Requirements
· General The requirements called out in this specification dealing with equipment evaluation are a minimum guide and shall not limit the testing and inspection to ensure compliance.
· Certification These test procedures shall be followed by the manufacturers who shall certify that they have conducted inspection and testing in accordance with this specification.
· Inspection A visual and physical inspection shall include mechanical, dimensional and assembly conformance of all parts of this specification.
· Environmental and Electrical All components, where applicable, shall properly operate within the following limits unless otherwise noted:
· Applied Line Voltage: 90 to 135 Vac
· Frequency: 60 (+/-3.0) Hertz
· Humidity: 5% to 95%
· Ambient Temperature: -34.6 °F to +165.2 °F
· Shock - Test per Specification MIL-STD-810G Method 516.6
· Vibration - per Specification MIL-STD-810G Method 514.6
· Commencement Operation All circuits, where applicable unless otherwise noted, shall commence operation at or below 90 Vac as the applied voltage is raised from 50 to 90 Vac at a rate of 2 (+/-0.5) volts / second.
· Equipment Compliance All equipment shall be unaffected by transient voltages normally experienced on commercial power lines. Where applicable, equipment purchased separately from the cabinet (which normally is resident) will be evaluated for compliance.
· Power Line Surge Protection The power line surge protection shall enable the equipment being tested to withstand (Non-destructive) and operate normally following the discharge of a 25 μF capacitor charged to ± 2,000 volts, applied directly across the incoming AC line at a rate of once every 10 seconds for a maximum of 50 occurrences per test. The unit under test will be operated at 68 °F ± 41 °F and at 120 (±12) Vac.
· Operating The equipment shall withstand (Non-destructive) and operate normally when one discharge pulse of plus or minus 300 volts is synchronously added to its incoming AC power line and moved uniformly over the full wave across 360 degrees or stay at any point of Line Cycle once every second. Peak noise power shall be 5 kilowatts with a pulse rise time of 500 ns. The unit under test will be operated at 68 °F ±41 °F and at 120 (+/-12) Vac.
· UL Requirements Equipment shall comply only with the requirements of UL Bulletin of Research No.
23, "Rain Tests of Electrical Equipment."
· Operational Conditions All equipment shall continue normal operation when subjected to the following:
· Temperature Test With the item functioning at a line voltage over Electrical Range the Device in its intended operation, the ambient temperature shall be lowered from 68 °F to 34.6 °F at a rate of not more than 64.4 °F per hour. The item shall be cycled at -34.6 °F for a minimum of 5 hours and then returned to 68 °F at the same rate.
· High Temperature Test With the item functioning at a line voltage over Electrical Range the Device in its intended operation, the ambient temperature shall be raised from 68 °F to 165.2 °F at a rate of not more than 64.4 °F per hour. The item shall be cycled at 165.2 °F for 5 hours and then returned to 68 °F at the same rate. The test shall be repeated with the line voltage at 135 Vac.
· Normal Operation All equipment shall resume normal operation following a period of at least 5 hours at -34.6 °F and less than 10 percent humidity and at least 5 hours at 165.2 °F and 22% humidity, when 90 Vac is applied to the incoming AC.
· Humidity and Ambient Temperature The relative humidity and ambient temperature values in the following table shall not be exceeded.
Ambient Temperature/ Dry Bulb (in 0F) Relative Humidity (in percent) Ambient Temperature/ Wet Bulb (in 0F)
| ‐34.6 to 33.98 |
| 10 |
| 1.04 to 108.86 |
| 33.98 to 114.8 |
| 95 |
| 108.86 |
| 119.84 |
| 70 |
| 108.86 |
| 129.92 |
| 50 |
| 108.86 |
| 140 |
| 38 |
| 108.86 |
| 149.72 |
| 28 |
| 108.86 |
| 160.16 |
| 21 |
| 108.86 |
| 165.2 |
| 18 |
| 108.86 |
· Quailty Control/ Final Acceptance Testing A complete QC / final test report shall be supplied with every ATCC. The test report shall indicate the name of the tester and shall be signed by a responsible manager.
· Cabinet Print Wiring diagram sheets for the cabinet shall be furnished in a weatherproof plastic pouch placed in the cabinet. Cabinet wiring diagrams shall be on non-fading.
8.0 Warranty
· ATC Cabinet and Assemblies ATCC will be covered by a minimum 1-year warranty from the date of delivery. Vendor will warrant its products to be free of defects in workmanship and/ or material. The supplier shall correct any defects at no cost to UDOT. Additionally, the supplier is responsible for shipping costs or on-site supplier technical services associated with defect repairs or defective component replacements.
· ATCC Components All ATCC components are covered under the manufacturer's standard warranty.
END OF ATTACHMENT C DETAILED SCOPE OF WORK AND REQUIREMENTS