QA_8.7.2018.pdf
PDF 43 KB Posted
- Attached to
- NM FLAP US60(1) Federal contract opportunity
- Solicitation number
- 6982AF18B000023
About this file
Questions and Answers
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| NM_FLAP_US60(1)_Bid_Tabulation_6982AF18B000023.pdf | ||
| Bid_Opening_Summary_8.8.18.pdf | ||
| Amendment_A002_final.pdf | ||
| Amend_A001_Attachments.pdf | ||
| SF30_Amend_A001_7_30_2018.pdf | ||
| NM_FLAP_US60(1)_Old_US60_Bridge_Final_Plan_set.pdf | ||
| ROW_CERT_FLAP_US60(1)_Old_US60_Bridge_Signed.pdf | ||
| NM_FLAP_US60(1)_Utility_Certification_Signed.pdf | ||
| NM_FLAP_US60(1)_-_UtilityDataQualityLevelCertification.pdf | ||
| 6982AF18B000023_Solicitation_NM_FLAP_US60(1).pdf | ||
| NM_FLAP_US60(1)_CrossSections.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation: 6982AF18B000023 FLAP US 60 Solicitation 6982AF18B000023 Questions/Answers
1. What is the shipping address for the FHWA-Central Federal Lands Highway’s Laboratory for the concrete cylinder samples? Can a local testing agency be used in lieu of sending the samples to the FHWA lab? Please see the latest revisions to the Special Contract Requirements under Section 154 that was posted on FedBizOpps. Section 154.03 Sampling was revised to say: Provide packaged verification cylinders for shipping to the CO for transport to the FHWA- Central Federal Lands Highway’s Laboratory unless other testing facilities are authorized by the CO. The contractor is responsible providing packaging to the Government to ship the Quality Assurance splits for the Government to ship their splits. The contractor will only be responsible for testing the quality control samples and will not be responsible for shipping samples to the FHWA-Central Federal Lands Highway’s Laboratory.
2. Sheet RG3099-B Steel Pipe Piling Notes says to see Special Contract Requirements for driven piles but the SCR document does not have any notes for that section. Can you clarify? The plan sheet should have referenced Standard Specifications for Construction of Roads and Bridges on Federal Highway Projects, FP14. Please refer to the FP-14 for all specifications related to the steel pipe piling.
| Solicitation: 6982AF18B000023 |
| FLAP US 60 Solicitation 6982AF18B000023 Questions/Answers |
File details come from the government source that posted it.