Revised-Mobile Janitorial Freq Charts updated floor freq- March 5 2026.xlsx
XLSX spreadsheet 25 KB Posted
- Solicitation number
- 697DCK-26-R-00056
About this file
This file is a Mobile Janitorial Frequency Chart that details the cleaning requirements for the Mobile Air Traffic Control Tower (ATCT) located at 101 Flave Pierce Road, Mobile, AL 36608. The facility operates from 6:00 AM to 11:00 PM with operational cleaning occurring between 6:00 AM and midnight. The total estimated square footage is 8,959 square feet, comprised of 2,597 carpeted and 6,362 uncarpeted square feet. The facility contains multiple functional areas including shared office space (1,683 sq ft), multi-operational areas (780 sq ft), corridors and hallways (1,404 sq ft), restrooms (320 sq ft with 5 single-use facilities), breakrooms and kitchens (483 sq ft), conference rooms (288 sq ft), mechanical and equipment rooms (2,704 sq ft combined), and reception areas (500 sq ft).
Cleaning frequencies vary by area type, with high-traffic zones such as restrooms, breakrooms, and smoking areas requiring twice-daily service seven days per week (2D7), while general office spaces, corridors, and reception areas require daily service seven days per week (D7). Specific tasks include waste and recycling policing, surface dusting, window cleaning, carpet vacuuming and shampooing, floor mopping and waxing, restroom disinfection, and supply dispensing replenishment. The frequency chart incorporates weekly, monthly, and quarterly cleaning schedules for various maintenance tasks. This amendment supersedes the original frequency chart by extending operational cleaning hours from 6:00 AM to 12:00 PM to 6:00 AM to midnight and reducing restroom cleaning frequency from 3D7 to 2D7, reflecting updated service requirements for the Mobile ATCT facility under FAA solicitation 697DCK-26-R-00056.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N24x7 25+
| Name & Ident of Facility: MOBILE ATCT | *All counts and Sq. Ft. provided are estimates for planning purposes only* |
| Address: 101 FLAVE PIERCE ROAD MOBILE , AL 36608 | |
| Facility Operating Hours: 6:00AM - 11:00PM | |
| Timeframe to clean Operational Area(s): 6:00AM -12:00am (midnight) | |
| General Frequency |
Non-24/7 Facilities
| Occupancy 25+ | Est. Carpeted Sq. Ft.* | Est. Uncarpeted Sq. Ft.* | Est. Total Square Footage* | ||||||||||||||||||
| (Cumulative) | Item Count* | Waste/Recycle Receptacles | Policing Grounds | Smoking Receptacles | Surface Dusting & Cleaning | High Surface Dusting & Cleaning | Vacuum/Polish Furniture | Windows | Window Covers | Vacuum Carpeted Floors, Rugs & Mats | Shampoo/Steam Clean Carpets, Rugs, & Mats | Clean/Mop Uncarpeted Floors | Clean/Strip/Wax Uncarpeted Floors | Buff Uncarpeted Floors | Replenish Supply Dispensers | Clean/Disinfect | Clean Glass, Mirrors, and Fixtures | ||||
| SOW Reference | 3.1 | 3.2 | 3.3 | 3.4 | 3.5 | 3.6 | 3.7 | Multi | |||||||||||||
| Operational Areas (nonoperational equipment/fixtures) | 780 | 780 | 2D7 | - | - | D7 | W | M | - | - | D7 | Q | D7 | SA | M | D7 | D7 | D7 | |||
| Shared Office Space | 995 | 688 | 1,683 | D7 | - | - | D5 | W | Q | W | Q | D5 | Q | D5 | SA | M | - | D5 | W | ||
| Single Occupancy Office Space | 384 | 54 | 438 | D7 | - | - | W | W | Q | W | Q | W | Q | W | SA | M | - | W | W | ||
| Conference Rooms | 288 | 288 | D7 | - | - | D5 | W | Q | W | Q | D5 | Q | D5 | SA | M | - | D5 | W | |||
| Reception Areas/Lobbies | 50 | 450 | 500 | D7 | - | - | D7 | W | Q | D7 | Q | D7 | Q | D7 | SA | M | D7 | D7 | D7 | ||
| Corridors, Hallways | 1,404 | 1,404 | D7 | - | - | D7 | W | - | W | Q | D7 | Q | D7 | SA | M | - | D7 | W | |||
| All Breakrooms/Kitchens/Queue Lines | 36 | 447 | 483 | 2D7 | - | - | 2D7 | W | M | W | Q | 2D7 | Q | 2D7 | SA | M | 2D7 | 2D7 | D7 | ||
| All Mechanical Rooms | 1,212 | 1,212 | D7 | - | - | - | - | - | - | - | Q | - | - | - | - | - | |||||
| All Equipment Rooms | 1,492 | 1,492 | D7 | - | - | - | - | - | - | Q | - | - | - | - | - | ||||||
| Janitor Closets/Areas/Rooms | 38 | 38 | 2D7 | - | - | W | - | - | W | Q | W | Q | W | SA | M | W | W | W | |||
| All Restrooms | 320 | 320 | 2D7 | - | - | 2D7 | W | - | W | Q | - | - | 2D7 | SA | M | 2D7 | 2D7 | 2D7 | |||
| Smoking Area/Shelter | 257 | 257 | 2D7 | D7 | D7 | D7 | W | W | Q | D7 | Q | D7 | SA | M | - | D7 | D7 | ||||
| Elevator | 64 | 64 | 1 | - | - | - | D7 | M | - | - | - | D7 | Q | D7 | SA | M | - | D7 | D5 | ||
| High-Use Stairwells (Frequent/Daily Use) - # of Levels | 7 | - | - | - | D7 | M | - | W | Q | D7 | - | - | - | 2D7 | D5 | ||||||
| Low-Use Stairwells (Infrequent Use) - # of Levels | 0 | - | - | - | W | M | - | - | - | - | W | - | - | - | W | - | |||||
| Appliances | 10 | - | - | - | D7 | - | - | - | - | - | - | - | - | - | - | D7 | D7 | ||||
| Refrigerators Interior | 3 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | M | - | ||||
| Drinking Fountains/Bottle Fill Stations | 7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2D7 | 2D7 | ||||
| HVAC air registers/grilles/diffusers | - | - | - | M | Q | - | - | - | - | - | - | - | - | - | - | - | |||||
| Dumpster Area | - | D7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||
| Sidewalks/Grounds | 2D7 | D7 | D7 | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||
| Rugs and Mats | - | - | - | - | - | - | - | - | D7 | Q | - | - | - | - | - | - | |||||
| Estimated Sq. Ft. Totals | 2,597 | 6,362 | 8,959 |
| Chart Key |
| D7 = 1x Day, 7 Days/Wk |
| 2D7 = 2x Day, 7 Days/Wk |
| 3D7 = 3X Day, 7 Days/Wk |
| D5 = 1x Day, 5 Days/Wk |
| W = Once Weekly |
| M = Once Monthly |
| Q = Quarterly |
| SA = Semi-Annually (Twice a Year) |
| Est. Square Feet | |||||
| Total Restrooms* | Quantity | Toilets | Urinals | Avg. Per Restroom | Total |
Sq Ft
| Single Use Restroom | 5 | 1 | 0 | 64 | 320 |
| Multi-Use Medium Restroom | 2-3 | 0-2 | 0 | ||
| Multi-Use Large Restroom | 4 + | 3 + | 0 | ||
| Total Est. Sq. Ft. | 320 |
File details come from the government source that posted it. Updated .