This document package includes a final report and related federal contract opportunity. The final report details asbestos and lead-based paint sampling conducted at an existing Air Route Surveillance Radar facility located in Pico Del Este, Puerto Rico. Eighteen bulk samples were collected and analyzed, with no detectable asbestos found. Fifteen XRF readings were taken, with lead presence above regulatory thresholds detected on various exterior and interior metal components.
The related federal contract opportunity involves furnishing all labor, equipment and materials to complete waterproofing of the exterior envelope of the Air Route Surveillance Radar facility. Scope includes full removal and replacement of exterior wall panels and insulation, as well as exterior staircase, platform and lighting refurbishments. The contractor will be responsible for accomplishing all work items in accordance with the solicitation, specifications, drawings and provisions. The federal agency is the Department of Transportation Federal Aviation Administration Southwestern Region.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Analytical Environmental Services International, Inc.
#611 2nd Floor Monserrate Street, Santurce Puerto Rico, 00907
Tel. (787) 722-0220 Fax (787) 724-5788
For your Environmental situation …we have the solution!
April 7, 2021
Sushma Patel
Civil Engineer
ESA Engineering Services
404-305-7223
404-326-2054
Sushma.Patel@faa.gov
RE: ACM/LBP Sampling event for QJQ ARSR Exterior Building Restoration located on FAA Long
Range Radar Sites in Pico del Este, Rain Forest El Yunque, Puerto Rico.
Dear Mrs. Patel:
AES International Inc. was contracted to conduct a lead and asbestos sampling event for QJQ ARSR Exterior
Building Restoration located on FAA Long Range Radar Sites in Pico del Este. The sampling was conducted on April 1, 2021 by Elme Rivera, an DRNA certified Lead Risk Assessor and Asbestos Inspector (see credentials in Appendix I). Below you will find a summary of the findings:
ACM
Eighteen (18) bulk samples were collected from suspect ACM located on site. Asbestos fibers were not detected in any of the samples collected and analyzed (see Appendix II for analytical results).
LBP
Sampling for Lead Based Painted (LBP) components was conducted using an XRF spectrum analyzer (serial
#2222). Fifteen (15) readings (9 inside and 6 outside the structure) were taken from the site. Results are presented in tabulated forms (see Appendix III). Lead presence (above LBP definition threshold of 1.0 mg/cm2) was detected as follow:
Exterior
Gray metal ladder
Interior
Gray/white metal Column
Gray metal Floor
Yellow/gray metal Ladder
If you need any further information, please do not hesitate to contact us, 787-722-0220.
Sincerely, Ady Padan Ph.D, P.G.
President mailto:Sushma.Patel@faa.gov
Forma P GC-009
GOBIERNO DE PUERTO RICO
OFICINA DEL GOBERNADOR
JUNTA DE CALIDAD AMBIENTAL
Área de Calidad de Agua
CERTIFICACION DE NO PRESENCIA DE ASBESTO
EN ESTRUCTURAS A DEMOLERSE
(Deberá completarse en letra de molde o impresa)
PGC-_____________________
PARA USO OFICIAL
(Nombre) (Estado Civil) (Municipio)
Dirección Postal__________________________________ _________________________________________________ demolición se encuentra libre de asbesto.
2. La información antes indicada es cierta y correcta.
3. Afirmo y reconozco las consecuencias de incluir y someter información falsa en este documento.
(Municipio)
Firma y Sello del Profesional o
Firma del Inspector de Asbesto registrado por la JCA (Original)
Nota: Ingenieros o Arquitectos deberán someter evidencia de que se encuentra al día en el pago de sus cuotas de colegiación e Inspectores de Asbesto deberán someter evidencia de la tarjeta de registro provista por la JCA.
Dirección Física: Ave. Ponce de León 1308, Carr. Estatal 8838, Sector el Cinco, Río Piedras, PR 00926
Dirección Postal: Apartado 11488, Santurce, PR 00910-
Elme Rivera Casado Yo, ______________________________, mayor de edad,______________, y vecino de__ _______________________ Vega Baja
Vega Baja Lakes Calle 11 L31 00693 (Pueblo) (Zip Code)
Vega Baja
787 724 5788
969 1311 787 722 0220
4. Para que así conste, firmo la presente certificación en ___________________ __________________ de Puerto Rico, Tel. (787) 767-8181 • Fax (787) 767-1962 hoy día ____ de ____________________ de ________
Teléfonos: Residencial (______) ______- ________ Oficina (______) ______- ________ Ext.________ Fax (______) ______- ________
Certifico que:
1. La estructura localizada en__________________________________________________, la cual será objeto de una
* Esta certificacion es exclusivamente para las areas muestreadas.
San Juan
8 abril 2021 amarin Typewritten text Exterior Building Restoration on FAA Long Range Radar Pico del Este, Rio Grande, Puerto Rico
Appendix I
AIHA Laboratory Accreditation Programs, LLC acknowledges that
Analytical Environmental Services International, Inc.
611 Monserrate St. Suite 2 Santurce, PR 00907
Laboratory ID: LAP-102702 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2017 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: February 01, 2023
ENVIRONMENTAL LEAD Accreditation Expires: February 01, 2023
ENVIRONMENTAL MICROBIOLOGY Accreditation Expires:
FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires:
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2017 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
Revision19: 09/01/2020
Cheryl O Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC
Date Issued: 02/28/2021
Lead Risk Assessor Credentials
Asbestos Inspector Credentials
Appendix II
TESTING
PH. (787) 722-0220 Fax (787) 724-5788
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
RESULT OF ANALYSIS (BY % AREA VISUAL ESTIMATE)
Project Name:
Non - Fibrous Material
Other Fibers
Asbestos Fibers
Asbestos Detected
Sample DescriptionClient Sample ID
Lab Sample ID
Client Name:
ACM Sampling for QJQ ARSR Exterior Building Restoration on FAA Long Range Radar Sites, Pico del Este, Rain Forest El Yunque
04/05/2021Date Received:
Project ID:
Date Collected: 04/01/2021FAA
Comments:
Rubber 95 Glue 5
NoSoft, Foam with Glue WhiteB21040001.01.A
RR-ER1
Layer % of Total :100%
B21040001.01
Sample of Insulation Panel, South SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Foam 94 Glue 6
NoSoft, Foam with Glue WhiteB21040001.02.A
RR-ER2
Layer % of Total :100%
B21040001.02
Sample of 2" Rigid Insulation Panel, South SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Foam 96 Glue 4
NoSoft, Foam with Glue WhiteB21040001.03.A
RR-ER3
Layer % of Total :100%
B21040001.03
Sample of Insulation Panel, West SideSample Location:
Date Analyzed: 04/07/2021
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
[Elme Rivera]
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
RESULT OF ANALYSIS (BY % AREA VISUAL ESTIMATE)
Project Name:
Non - Fibrous Material
Other Fibers
Asbestos Fibers
Asbestos Detected
Sample DescriptionClient Sample ID
Lab Sample ID
Client Name:
ACM Sampling for QJQ ARSR Exterior Building Restoration on FAA Long Range Radar Sites, Pico del Este, Rain Forest El Yunque
04/05/2021Date Received:
Project ID:
Date Collected: 04/01/2021FAA
Comments:
Glue 98Glass Fibers 2NoHard, Glue With Fibers GrayB21040001.04.A
RR-ER4
Layer % of Total :100%
B21040001.04
Caulking of PVC Corrugated Panel, South SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Glue 97Glass Fibers 3NoHard, Glue With Fibers GrayB21040001.05.A
RR-ER5
Layer % of Total :100%
B21040001.05
Caulking of PVC Corrugated Panel, West SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Glue 98Glass Fibers 2NoHard, Glue With Fibers GrayB21040001.06.A
RR-ER6
Layer % of Total :100%
B21040001.06
Caulking of PVC Corrugated Panel, North SideSample Location:
Date Analyzed: 04/07/2021
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
RESULT OF ANALYSIS (BY % AREA VISUAL ESTIMATE)
Project Name:
Non - Fibrous Material
Other Fibers
Asbestos Fibers
Asbestos Detected
Sample DescriptionClient Sample ID
Lab Sample ID
Client Name:
ACM Sampling for QJQ ARSR Exterior Building Restoration on FAA Long Range Radar Sites, Pico del Este, Rain Forest El Yunque
04/05/2021Date Received:
Project ID:
Date Collected: 04/01/2021FAA
Comments:
Foam 88 Binders/Paint 10
Glass Fibers 2NoSemi-Hard, Foam with Paint and Fibers Yellow
B21040001.07.A
RR-ER7
Layer % of Total :100%
B21040001.07
Paint Included as Binders
Insulation of Interior Metal Chanel Under PVC Panel, SouthSample Location:
Date Analyzed: 04/07/2021
Comments:
Foam 87 Binders/Paint 10
Glass Fibers 3NoSemi-Hard, Foam with Paint and Fibers Yellow
B21040001.08.A
RR-ER8
Layer % of Total :100%
B21040001.08
Paint Included as Binders
Insulation of Interior Metal Chanel Under PVC Panel, WestSample Location:
Date Analyzed: 04/07/2021
Comments:
Foam 86 Binders/Paint 12
Glass Fibers 2NoSemi-Hard, Foam with Paint and Fibers Yellow
B21040001.09.A
RR-ER9
Layer % of Total :100%
B21040001.09
Paint Included as Binders
Insulation of Interior Metal Chanel Under PVC Panel, NorthSample Location:
Date Analyzed: 04/07/2021
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
RESULT OF ANALYSIS (BY % AREA VISUAL ESTIMATE)
Project Name:
Non - Fibrous Material
Other Fibers
Asbestos Fibers
Asbestos Detected
Sample DescriptionClient Sample ID
Lab Sample ID
Client Name:
ACM Sampling for QJQ ARSR Exterior Building Restoration on FAA Long Range Radar Sites, Pico del Este, Rain Forest El Yunque
04/05/2021Date Received:
Project ID:
Date Collected: 04/01/2021FAA
Comments:
Foam 92 Glue 6
Synthetic 2NoSoft, Foam Rubber with Glue and Fibers Black
B21040001.10.A
RR-ER10
Layer % of Total :100%
B21040001.10
Insulation of Water Pipe (Chilled Water) Under Radar, SouthSample Location:
Date Analyzed: 04/07/2021
Comments:
Foam 94 Glue 4
Synthetic 2NoSoft, Foam Rubber with Glue and Fibers Black
B21040001.11.A
RR-ER11
Layer % of Total :100%
B21040001.11
Insulation of Water Pipe (Chilled Water) Under Radar, SouthwestSample Location:
Date Analyzed: 04/07/2021
Comments:
Foam 90 Glue 7
Synthetic 3NoSoft, Foam Rubber with Glue and Fibers Black
B21040001.12.A
RR-ER12
Layer % of Total :100%
B21040001.12
Insulation of Water Pipe (Chilled Water) Under Radar, WestSample Location:
Date Analyzed: 04/07/2021
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
RESULT OF ANALYSIS (BY % AREA VISUAL ESTIMATE)
Project Name:
Non - Fibrous Material
Other Fibers
Asbestos Fibers
Asbestos Detected
Sample DescriptionClient Sample ID
Lab Sample ID
Client Name:
ACM Sampling for QJQ ARSR Exterior Building Restoration on FAA Long Range Radar Sites, Pico del Este, Rain Forest El Yunque
04/05/2021Date Received:
Project ID:
Date Collected: 04/01/2021FAA
Comments:
Glue 5 Binders/Paint 93
Synthetic 2NoHard, Plastic with Paint, Glue and Fibers White
B21040001.13.A
RR-ER13
Layer % of Total :100%
B21040001.13
Paint Included as Binders
PVC Corrugated External Wall Panel, South SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Glue 6 Binders/Paint 91
Synthetic 3NoHard, Plastic with Paint, Glue and Fibers White
B21040001.14.A
RR-ER14
Layer % of Total :100%
B21040001.14
Paint Included as Binders
PVC Corrugated External Wall Panel, Southeast SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Glue 6 Binders/Paint 91
Synthetic 2NoHard, Plastic with Paint, Glue and Fibers White
B21040001.15.A
RR-ER15
Layer % of Total :100%
B21040001.15
Paint Included as Binders
PVC Corrugated External Wall Panel, West SideSample Location:
Date Analyzed: 04/07/2021
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
RESULT OF ANALYSIS (BY % AREA VISUAL ESTIMATE)
Project Name:
Non - Fibrous Material
Other Fibers
Asbestos Fibers
Asbestos Detected
Sample DescriptionClient Sample ID
Lab Sample ID
Client Name:
ACM Sampling for QJQ ARSR Exterior Building Restoration on FAA Long Range Radar Sites, Pico del Este, Rain Forest El Yunque
04/05/2021Date Received:
Project ID:
Date Collected: 04/01/2021FAA
Comments:
Binders/Paint 97Synthetic 3NoHard, Plastic with Paint and Fibers Gray
B21040001.16.A
RR-ER16
Layer % of Total :100%
B21040001.16
Paint Included as Binders
PVC External Corner Cap, South SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Binders/Paint 95Synthetic 5NoHard, Plastic with Paint and Fibers Gray
B21040001.17.A
RR-ER17
Layer % of Total :100%
B21040001.17
Paint Included as Binders
PVC External Corner Cap, West SideSample Location:
Date Analyzed: 04/07/2021
Comments:
Binders/Paint 96Synthetic 4NoHard, Plastic with Paint and Fibers Gray
B21040001.18.A
RR-ER18
Layer % of Total :100%
B21040001.18
Paint Included as Binders
PVC External Corner Cap, North SideSample Location:
Date Analyzed: 04/07/2021
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
611 Monserrate Street, 2nd. Floor, Santurce, P.R. 00907
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
B21040001Job ID:
POLARIZED LIGHT MICROSCOPY (PLM) BULK SAMPLE ANALYSIS REPORT
REPORT NUMBER
RP21040702
Comments:
FOR ALL HETEROGENEOUS AND LAYERED SAMPLES EASILY SEPARATED INTO SUBLAYERS, EACH COMPONENT IS ANALYZED AND REPORTED SEPARATELY.
SAMPLE WAS ANALYZED BY PLM USING DISPERSION STAINING TECHNIQUES IN ACCORDANCE WITH US EPA METHOD: 600/M4-82/020 of Dec. 1982 and 600/R-93/116 OF JULY 93.
EPA - 40 CFR APPENDIX E TO SUBPART E OF PART 763,INTERIM METHOD OF THE DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES.
MICROANALYST:
PLM IS NOT CONSISTENTLY RELIABLE IN DETECTING SMALL CONCENTRATION OF ASBESTOS IN FLOOR TILES AND SIMILAR NONFRIABLE MATERIALS. QUANTITATIVE TEM IS CURRENTLY THE ONLY METHOD THAT CAN BE USED TO GET THE CONCLUSIVE ASBESTOS CONTENT. THIS REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL AND NOT WITHOUT WRITTEN APPROVAL OF THE LABORATORY. THIS REPORT SHALL NOT BE USED TO CLAIM ENDORSEMENT BY NVLAP OR ANY AGENCY OF OF THE US GOVERNMENT. METHOD IS USED FOR DETERMINATION OF ASBESTOS IN BULK SAMPLES IS INTERIM METHOD FOR DETERMINATION OF ASBESTOS IN BULK INSULATION SAMPLES (EPA 600/M4-82-020) AS FOUND IN 40 CFR,PART 763, APPENDIX E TO SUBPART E.
Appendix III
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
611 Monserrate Street, 2nd. Floor, Santurce, P. R. 00907
Client Name: FAA/ESA Engineering Services 4/1/21
Project Name: Exterior Building Restoration on FAA Long Range Radar, Pico del Este Elme Rivera
Address: Rio Grande, Puerto Rico 2222
Reading # Structure Room Substrate Color Component & Location
XRF
Reading
Laboratory
Result (% or mg/cm
1 Calibration 1.0
2 Calibration 1.1
3 Calibration 1.1
4 South Exterior Building PVC Green Corrugated Panel 0.1
5 South Exterior Building Metal Green Inside Panel 0.2
6 South Exterior Building Metal Green Exterior Staircase Column 0.8
7 South Exterior Building Metal Green Exterior Staircase Handrail 0.6
8 South Exterior Building Concrete Green/Gray Exterior Staircase Base 0.4
9 South Exterior Building Metal Gray Exterior Ladder Rung 2.1
10 South Exterior Building Metal Gray Exterior Ladder Rail 2.3
11 South Exterior Building Concrete White Staircase Riser 0.1
12 South Exterior Building Concrete White Staircase Tread 0.3
13 Calibration 1.0
14 Calibration 1.0
15 Calibration 1.0
16 Radar Interior 1st Floor Metal Gray Lower Column 1.7
17 Radar Interior 1st Floor Metal White Upper Column 1.2
18 Radar Interior 1st Floor Concrete Gray Floor 0.3
19 Radar Interior 2nd Floor Metal Gray Floor 2.8
LEAD BASED PAINT TESTING DATA SHEET
Date:
Inspector:
XRF Serial No.:
Approved by: Ady Padan, Ph.D Date: 4/1/2021
ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.
611 Monserrate Street, 2nd. Floor, Santurce, P. R. 00907
Client Name: FAA/ESA Engineering Services 4/1/21
Project Name: Exterior Building Restoration on FAA Long Range Radar, Pico del Este Elme Rivera
Address: Rio Grande, Puerto Rico 2222
Reading # Structure Room Substrate Color Component & Location
XRF
Reading
Laboratory
Result (% or mg/cm
LEAD BASED PAINT TESTING DATA SHEET
Date:
Inspector:
XRF Serial No.:
20 Radar Interior 2nd Floor Metal Yellow Lower Ladder 1.5
21 Radar Interior 2nd Floor Metal Gray Upper Ladder 1.0
22 Calibration 1.0
23 Calibration 1.0
24 Calibration 1.1
Final Calibration and Retesting on QJQ Catwalk XRF Data, done the same day.
Approved by: Ady Padan, Ph.D Date: 4/1/2021
Appendix IV
Selective Photos- Exterior Building Restoration
General View of Radar Structure
Gray Metal Exterior Ladder Rung & Rail Painted with LBP
Exterior Building, South
XRF Reading #9 and #10
White Metal Upper Column and Gray Metal Lower Column
Painted with LBP
Interior, 1st Floor- Radar
XRF Readings #16 and #17
Gray Metal Floor
Painted with LBP
Interior, 2nd Floor- Radar
XRF Reading #19
Gray Metal Upper Ladder
Painted with LBP
Interior, 2nd Floor- Radar
XRF Reading #21
Yellow Metal Lower Ladder
Painted with LBP
Interior, 2nd Floor- Radar
XRF Reading #20