Attachment 1a - FINAL 100% Drawings 07-12-18.pdf

PDF 11 MB Posted

Attached to
AMENDMENT 0003: MAJOR MECHANICAL UPGRADES PROJECT AT FAA'S DENVER ARTCC FACILITY IN LONGMONT, CO
Solicitation number
697DCK-18-R-00406
Issued by

About this file

Attachment 1a - FINAL 100% Drawings 07-12-18 (pdf)

View the file

Other files

File Type Posted
Question 30 - RMD-502-40479-A07.pdf PDF
697DCK-18-R-00406 Amend 0003.pdf PDF
Attachment 2 - Past Performance Survey.docx DOCX document
697DCK-18-R-00406.pdf PDF
697DCK-18-R-00406 Amend 0001.pdf PDF
Question 29 - List of Furniture.pdf PDF
Question 30 - RMD-502-40479-A05.pdf PDF
Attachment 1a - FINAL 100% Drawings 07-12-18.pdf PDF
Question 18 and 19 - ZDV-1401893-M901.pdf PDF
697DCK-18-R-00406 Amend 0002.pdf PDF
Question 61 - 23 21 23 Hydronic Pumps Amendment 10.10.pdf PDF
Attachment 1 - Final 100% Specifications 7-31-2018.pdf PDF
Question 30 - RMD-502-40479-A06.pdf PDF
Question 92 - FAA Order 6000.50E.pdf PDF
Attachment 4 - SF-1413 Subcontractor.pdf PDF
Question 52, 72, and 74 - FAA-STD-019f.pdf PDF
Attachment 3 - DB WD CO180027 dated 8-3-2018.pdf PDF
Question 30 - RMD-502-40479-A07.pdf PDF
Attachment 1a - FINAL 100% Drawings 07-12-18.pdf PDF
Question 52, 72, and 74 - FAA-STD-019f.pdf PDF
Question 30 - RMD-502-40479-A06.pdf PDF
Question 61 - 23 21 23 Hydronic Pumps Amendment 10.10.pdf PDF
Question 92 - FAA Order 6000.50E.pdf PDF
Attachment 4 - SF-1413 Subcontractor.pdf PDF
697DCK-18-R-00406 Amend 0002.pdf PDF
Question 18 and 19 - ZDV-1401893-M901.pdf PDF
Question 30 - RMD-502-40479-A05.pdf PDF
697DCK-18-R-00406.pdf PDF
Attachment 2 - Past Performance Survey.docx DOCX document
Attachment 1 - Final 100% Specifications 7-31-2018.pdf PDF
697DCK-18-R-00406 Amend 0001.pdf PDF
Attachment 3 - DB WD CO180027 dated 8-3-2018.pdf PDF
Question 29 - List of Furniture.pdf PDF
Attachment 1 - Final 100% Specifications 7-31-2018.pdf PDF
697DCK-18-R-00406.pdf PDF
Attachment 4 - SF-1413 Subcontractor.pdf PDF
Attachment 3 - DB WD CO180027 dated 8-3-2018.pdf PDF
Attachment 2 - Past Performance Survey.docx DOCX document
697DCK-18-R-00406 Amend 0001.pdf PDF
697DCK-18-R-00406.pdf PDF
Attachment 4 - SF-1413 Subcontractor.pdf PDF
Attachment 2 - Past Performance Survey.docx DOCX document
Attachment 1a - FINAL 100% Drawings 07-12-18.pdf PDF
Attachment 1 - Final 100% Specifications 7-31-2018.pdf PDF
Attachment 3 - DB WD CO180027 dated 8-3-2018.pdf PDF
Attachment 3 - DB WD CO180027 dated 8-3-2018.pdf PDF
Attachment 1a - FINAL 100% Drawings 07-12-18.pdf PDF
Attachment 1 - Final 100% Specifications 7-31-2018.pdf PDF
Attachment 4 - SF-1413 Subcontractor.pdf PDF
697DCK-18-R-00406.pdf PDF
Show 40 more

Latest 50 of 51 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WIDTH HEIGHT DEPTH JA

M

B

H

EA

D

TH

R

ES

H

O

LD

11 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 45 10 2, 3, 4, 5, 8 B102 TELCO M-14 D4 HM 3'-0" 7'-0" 1-3/4" RHR Exist AL 1 3, 4, 7, 8 Boiler B116 M-15 D6 HM 3'-0" 7'-0" 1-3/4" RHR Exist AL 5 4, 7, 8 Chiller B115

17 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 9 5, 10 MCCs B112 18 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 9 5, 10 B118 Vestibule 20 D1 HM PR 3'-0" 7'-0" 1-3/4" RHR F1 HM 45 6 1, 5, 6, 10 Chiller B115 22 D4 HM 3'-0" 7'-0" 1-3/4" LHR Exist 45 7 1, 2, 4, 5, 8 B118 Ramp

23 D4 HM PR 3'-0" 7'-0" 1-3/4" LHR F1 HM 45 8 3, 5, 8, 10 IT B102A

25 D1 HM PR 3'-0" 7'-0" 1-3/4" LH/RH Exist 45 4 3, 4, 5, 6, 8 B120

27 D4 HM 3'-0" 7'-0" 1-3/4" LH F1 HM 90 7 5, 8, 10 TELCO B101

30 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM X 90 2 3, 5, 8, 10 B88

35 F1 HM 90 5, 10 B120

36 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 45 8 2, 5, 8, 10 Mech. B129 37 D4 HM 3'-0" 7'-0" 1-3/4" LHR Exist 45 8 2, 4, 5, 8 Closet 40 D1 HM PR 2'-6" 7'-0" 1-3/4" LHR/RHR F1 HM 90 11 5, 6,8,9,10 Corridor B109 43 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 45 8 3, 5, 8, 10 Corridor B108 44 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 45 9 5, 10 Electrical B111 45 D2 HM PR 3'-0" 7'-0" 1-3/4" RHR Exist X 90 9 4, 5, 8 HOST Mech. B119

46 D4 HM 2'-0" 6'-8" 1-3/4" LHR F1 HM X 90 7 5, 8, 10 HOST B134

49 D3 HM 4'-0" 7'-0" 1-3/4" RHR Exist 90 8 3, 4, 5, 6, 8 HOST B134 50 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 45 6 3, 4, 5, 6, 8 HOST B134 51 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 90 3 3, 4, 5, 6, 8 B120A

52 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 4 3, 5, 6, 8, 10 B120A

53 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 11 5, 6, 8, 9, 10 Corridor B109 56 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 90 9 2, 4, 5, 8 U-Chase 1 57 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 90 9 2, 4, 5, 8 U-Chase 2

1ER D5 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 12 5, 7 To Elect. Addition 2ER D4 HM 3'-0" 7'-0" 1-3/4" RHR F1 HM 12 5, 7 To Elect. Addition 1PH D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 12 5, 7 To Pumphouse

4 D5 HM 3'-0" 7'-0" 1-3/4" RH Exist HM 4, 5, 8,11 Corridor B109 5 D3 HM 3'-0" 7'-0" 1-3/4" RHR F1 HM 90 17 5, 10 Corridor B109

6 D4 HM 3'-0" 7'-0" 1-3/4" LH F1 HM 90 8 5, 10 STAIR 1

12 D5 HM 3'-0" 7'-0" 1-3/4" RH Exist HM 4, 5, 8, 11 Corridor B109 13 D5 HM 3'-0" 7'-0" 1-3/4" LHR Exist HM 4, 5, 8, 11* Corridor B109 19 D4 HM 3'-0" 7'-0" 1-3/4" RH Exist 15 4, 5, 13 B118 41 D4 HM 2'-6" 7'-0" 1-3/4" LH Exist 90 16 4, 5 Corridor B109 54 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 90 13 4, 5, 10, 12 Corridor B109 55 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 90 14 4, 5, 10 Corridor B109

1 D4 WD 2'-6" 4'-8" F1 WD 5 STAIR 1

EXC D3 HM 3'-6" 7'-0" F1 HM 5 B109 (EXERCISE)

TEL D4 HM 2'-0" 7'-0" F1 HM 5 B120 (TELCO)

11 Reuse existing hardare. *Replace closer only.

DOOR AND FRAME PAINTING ONLY (OPTION)

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A212 BASEMENT SOUTH

A212 BASEMENT SOUTH

A212 BASEMENT SOUTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A201 BOILER/CHILLER AREA

A201 BOILER/CHILLER AREA

DOOR, DOOR FRAME AND HARDWARE REPLACEMENT (OPTION)

Reuse Existing

DETAILS

FRAMEDOOR

NOMINAL SIZE

D O

O R

N O

TY

PE

M A

TE

R

IA

L

FI

R

E R

A

TI

N G

L A

B

EL

(M

IN

U

TE

S)

H A

R D

W A

R E

SE

T

N O

HANDING TYPE M

A

TE

R

IA

L

NOTE NUMBER

A211 BASEMENT NORTH

DRAWING REFERENCE

A201 BOILER/CHILLER AREA

ENTER TO ROOM

NUMBER(S) -

AREAS

A201 BOILER/CHILLER AREA

A211 BASEMENT NORTH

A201 BOILER/CHILLER AREA

A201 BOILER/CHILLER AREA

A201 BOILER/CHILLER AREA

DOOR SCHEDULE

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A212 BASEMENT SOUTH

A301 PUMPHOUSE

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A201 BOILER/CHILLER AREA

A201 BOILER/CHILLER AREA

A201 BOILER/CHILLER AREA

A201 BOILER/CHILLER AREA

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

A301 PUMPHOUSE

A301 PUMPHOUSE

A201 BOILER/CHILLER AREA

A212 BASEMENT SOUTH

A212 BASEMENT SOUTH

A212 BASEMENT SOUTH

A211 BASEMENT NORTH

A211 BASEMENT NORTH

Reuse existing closer and door stop. Replace lockset and hinges only.

DOOR SCHEDULE NOTES:

Reuse existing lockset and closer. Replace hinges only.

Connect to refrigerant leak detection system.

Reuse cast-in-place HM frame.

Coordinate with FAA's SSDI Contractor for door access control system.

Coordinate hardware with existing frame.

Paint doors and frames PT-3 unless noted otherwise.

Fire rated doors shall have fire rated safety glass.

Exterior insulated door.

May reuse existing frame.

These fire door(s) are normally open and shall be interfaced with the fire alarm control panel (FACP), and shall include appropriate releasing/hold-open devices and coordinating door hardware.

Replace with fire rated frame.

SPLICE LENGTH TABLE (4000PSI)

BAR SIZE

t < 12”, Ld

(INCHES)

t > 12”, Ld

(INCHES)

t < 12”, CLASS A

SPLICE,

LENGTH =

1.0Ld

(INCHES)

t < 12”, CLASS B

SPLICE,

LENGTH =

1.3Ld

(INCHES)

t > 12”, CLASS A

SPLICE,

LENGTH =

1.0Ld

(INCHES)

t > 12”, CLASS B

SPLICE,

LENGTH =

1.3Ld

(INCHES)

3 15 18 15 19 18 24 4 19 25 19 25 25 32 5 24 31 24 31 31 40 6 29 37 29 37 37 48 7 42 54 42 54 54 70 8 48 62 48 62 62 80 9 54 70 54 70 70 90 10 60 77 60 77 77 100 11 66 85 66 85 85 111

1. t = THICKNESS OF FRESH CONCRETE BELOW THE BOTTOM SURFACE OF A BAR

2. Ld = DEVELOPMENT LENGTH OF BAR

3. CLASS A SPLICE DOES NOT APPLY TO THIS PROJECT.

LOAD COMBINATION MAXIMUM REACTION TABLE (LBS)

FRAME

LINE

COL LINE

GRIDLINE LOAD ID H V COL LINE

GRIDLINE LOAD ID H V

1, 3 A 1 0 -693 B 1 0 -693

2 A 1 0 -1386 B 1 0 -1386

1, 3 A 2 0 -770 B 2 0 -770

2 A 2 0 -1540 B 2 0 -1540

1, 3 A 3 525 2136 B 3 525 35

2 A 3 1050 4274 B 3 1050 69

1, 3 A 4 0 -1216 B 4 0 -1217

2 A 4 0 -2433 B 4 0 -2433

1, 3 A 5 525 919 B 5 525 -1181

2 A 5 1050 1840 B 5 1050 -2364

HP

(EA.) VOLT PH MFGR MODEL/

SERIES

CT-1A 69.8 1,039 85.0 75.0 12.0 1 4 VARIABLE

SPEED 7.5 460 3 TOWER

TECH

TTXR-

041975

CT-1B 69.8 1,039 85.0 75.0 12.0 1 4 VARIABLE

SPEED 7.5 460 3 TOWER

TECH

TTXR-

041975

CT-1C 69.8 1,039 85.0 75.0 12.0 1 4 VARIABLE

SPEED 7.5 460 3 TOWER

TECH

TTXR-

041975

1. BASIS OF DESIGN IS TOWER TECH TTXR-041975.

RATED

CAPACITY

(TONS)

AIR

EWB

(°F) MAX

GPM

EWT

(°F)

LWT

(°F)

COOLING

TOWER YARD

MAXIMUM

WEIGHT

(LBS.)

KNOWN

ACCEPTABLE

SOURCE COMMENTS

COOLING TOWER SCHEDULE

STATIC

LIFT

(FT.)

CONDENSER WATER DATA

NO. OF

CELLS

NO. OF

FANS/

CELL SPEED

CONTROL

ELECTRICAL DATA

FAN AND MOTOR DATA

UNIT

NO. LOCATION SERVICE TYPE

NOTE 1, 2, 314,394360MECHANICAL DRAFT

COUNTER FLOW

CHILLERS

NOTES:

2. VIBRATION LIMIT SWITCH

3. SEE SHEET G002 FOR WIND LOADING.

NOTE 1, 2, 3

COOLING

TOWER YARD

CHILLERS MECHANICAL DRAFT

COUNTER FLOW

360 14,394 NOTE 1, 2, 3

COOLING

TOWER YARD

CHILLERS MECHANICAL DRAFT

COUNTER FLOW

360 14,394

TYPE QTY

(LBS.) TYPE MOUNT V PH HZ MFGR MODEL

CH-100 R-123 600 150 2 WATER 764 55.0 45.0 15.5 0.0001 150 2 WATER 904 75.0 85 18.3 0.00025 1 265 VAR

SPEED UNIT FIELD 185.9 314 500 460 3 60 TRANE CVHE

CH-200 R-123 600 150 2 WATER 764 55.0 45.0 15.5 0.0001 150 2 WATER 904 75.0 85 18.3 0.00025 1 265 VAR

SPEED UNIT FIELD 185.9 314 500 460 3 60 TRANE CVHE

UNIT

NO. LOCATION

RATED

CAPACITY

(TONS)

PART LOAD

EFFICIENCY/

IPLV (KW/TON)

REFRIDGERANT

EVAPORATOR DATA CONDENSER DATA

NO.

OF

PASS.

FLUID

TYPE

FLOW

RATE

(GPM)

PRESS

RATING

(PSIG)

NO.

OF

PASS.

FLUID

TYPE

FLOW

RATE

(GPM)

NO. OF

COMP.

FULL

LOAD

AMPS

(FLA)

EWT

(°F)

LWT

(°F)

MAX

PD

(FT.)

FOULING

FACTOR

PRESS

RATING

(PSIG)

COMMENTS

B115 320 0.3291 19,019 NOTES 1, 2

COMPRESSOR

DATA COMPRESSOR

MOTOR

CONTROLLER

POWER

CONN.

POWER

INPUT

(KW)

MIN.

CIRCUIT

AMPACITY

(A)

MAX

OCP

(A)

EWT

(°F)

LWT

(°F)

MAX

PD

(FT.)

FOULING

FACTOR

NOTES:

1. UNIT MUST MEET FEMP EFFICIENCY REQUIREMENTS

2. MARINE WATER BOX

CHILLER SCHEDULE - CENTRIFUGAL TYPE

FULL LOAD

EFFICIENCY(KW/

TON)

0.567

B115 320 0.567 0.3291 19,019 NOTES 1, 2

ELECTRICAL CHAR.

CHILLER ELECTRICAL REQUIREMENTS

MAXIMUM

WEIGHT (LBS)

KNOWN

ACCEPTABLE

SOURCE

VOLTS PH HZ

1000 150 1780 60 480 3 60

1000 150 1780 60 480 3 60

1000 150 1780 60 480 3 60

1000 150 1780 60 480 3 60

1100 110 1770 40 460 3 60

1100 110 1770 40 460 3 60

1100 110 1770 40 460 3 60

1. VARIABLE SPEED PUMP

2. 2-STAGE PUMP(TURBINES)

BELL & GOSSET VIT-DITM-12CMC NOTE 1, 2

P-3B PUMP HOUSE CONDENSER

WATER SYSTEM BELL & GOSSET VIT-DITM-12CMC NOTE 1, 2

P-3C PUMP HOUSE CONDENSER

WATER SYSTEM BELL & GOSSET

NOTES:

BELL & GOSSET HSC-S 6X8X12L NOTE 1

CHILLED WATER

SYSTEM

CHILLED WATER

SYSTEM

CHILLED WATER

SYSTEM

NOTE 1

BELL & GOSSET HSC-S 6X8X12L NOTE 1

BELL & GOSSET HSC-S 6X8X12L NOTE 1

PUMP SCHEDULE

COMMENTSGPM TDH

(FEET) RPM HP

ELECTRICAL DATA

UNIT NO. LOCATION SERVICE

KNOWN ACCEPTABLE SOURCE

MFGR MODEL/SERIES

VIT-DITM-12CMC NOTE 1, 2

P-1A B115 CHILLED WATER

SYSTEM

P-1B

P-1C

P-1D

P-3A CONDENSER

WATER SYSTEM

B115

B115

B115

PUMP HOUSE

BELL & GOSSET HSC-S 6X8X12L DIA IN LENGTH

IN

CAP

GAL

WATER 30 84 240TK-202 ATTIC DSR

MECH ROOM

CHILLED WATER

SYSTEM

DIAPHRAGM TYPE TANK

NOTES:

EXPANSION TANK SCHEDULE

REMARKSCONTENT

SIZE

UNIT NO. LOCATION SERVICE

TSP

(IN WG)

MAX OV

(FPM)

MAX

RPM

MAX

BHP HP VOLTS PH CLASS ROT. DISCH. ARRANG. DRIVE MFGR

EF-310 1,500

4,000 0.5 1800 600 0.89 1 480 3 - CW HORIZ. - BELT GREEN

HECK

EF-101A 990

VARIABLE - 1,700 - 1/3 115/230 1 - - HORIZ. - DIRECT CAN

ARM

EF-101B 580

690 - 1,600 - 1/20 115 1 - - HORIZ. - DIRECT CAN

ARM

SF-101 520 - 1725 - 1/4 115/230 1 - - HORIZ. - DIRECT AMERI

CRAFT

NOTE:

1. UNIT WITH MOTORIZED DAMPER.

2. UNIT WITH WIRE MESH SCREEN.

3. UNIT WITH 2-SPEED FAN

COMMENTS

CONSTRUCTION DATA KNOWN

ACCEPTABLE

MODEL/

SERIES

B116 CHILLER ROOM

EXHAUST

CENTRIFUGAL SFB-30 NOTE 1, 2, 3

PUMP

HOUSE

ELECTRICAL

ADDITION

INLINE

EXHAUST FAN SCHEDULE

UNIT

NO. LOCATION SERVICE CFM

PERFORMANCE DATA MOTOR DATA

TYPE FAN

S10-B2 NOTE 3

PUMP

HOUSE

PUMP HOUSE

EXHAUST

INLINE S12-EVD

PUMP

HOUSE

PUMP HOUSE

INTAKE

INLINE CAF-912-1/4

MFGR MODEL/

SERIES MFGR MODEL/

SERIES

FCV-1A B115 CH-100 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-2A B115 CH-200 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-3A B115 CH-300 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-4A B115 CH-400 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-1B B115 CH-100 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-2B B115 CH-200 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-3B B115 CH-300 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-4B B115 CH-400 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-1C B115 HX-1 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-1D B115 HX-1 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-5A COOLING

TOWER YARD CT-1A 10 904 5430 BUTTERFLY BRAY NYL2 120 3 2 POSITION BRAY S70

FCV-5B COOLING

TOWER YARD CT-1B 10 904 5430 BUTTERFLY BRAY NYL2 120 3 2 POSITION BRAY S70

FCV-5C COOLING

TOWER YARD CT-1C 10 904 5430 BUTTERFLY BRAY NYL2 120 3 2 POSITION BRAY S70

FCV-6 B113A CHILLED WATER

BYPASS 6 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FCV-7 PUMP HOUSE COOLING

TOWER BYPASS 6 904 1850 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70

FLOW CONTROL VALVE SCHEDULE

VALVE DATA

UNIT NO. LOCATION SERVICE

DESIGN

PIPE SIZE

(IN.)

KNOWN SOURCE COMMENTSFLOW

COEFFICIENT

(Cv)

DESIGN

FLOW

(GPM)

TYPE

ACTUATOR DATA

VOLTS CONTROL

SIGNAL

KNOWN SOURCE

PH

NOTES:

TSP

(IN WG)

MAX OV

(FPM)

MAX

RPM

MAX

BHP

HP

AMPS VOLTS PH BTU/HR GPM MFGR MODEL/ SERIES

UH-315 B115 CHILLER ROOM

HEAT 1625 - - - 1/8 1/8

2.3 115 1 55,000 7 MODINE HC-108

EUH-1 PUMP

HOUSE

PUMP HOUSE

HEAT 830 - - - - N/A

18.7 480 3 51,000 - MODINE HER-150

EUH-2 PUMP

HOUSE

PUMP HOUSE

HEAT 830 - - - - N/A

15.7 480 3 42,700 - MODINE HER-125

NOTE:

COMMENTS

CONSTRUCTION DATA KNOWN ACCEPTABLE

SOURCE

UNIT HEATER SCHEDULE

UNIT

NO. LOCATION SERVICE CFM

PERFORMANCE DATA MOTOR DATA

CAPACITY WATER

HP VOLTS PH HZ # FANS TOTAL

(MBH)

SENS.

(MBH) EDB ( ̊F) EWB ( ̊F) LDB ( ̊F) LWB ( ̊F) GPM ENT ( ̊F) LWT ( ̊F) TOTAL (MBH) GPM KW LBS/HR MFGR. MODEL/

SERIES

AHU-22 B119 B134 9,000 0.50 BELT - 10 460 3 60 2 146.7 146.7 72 54.7 58.9 49 55 46 58.7 10.20 30.00 8.00 2,4 16X20,16X25 DATA

AIRE

DACD-

AHU-104 B120 B120 18200 0.50 DIRECT - 4.2 460 3 60 3 302 302 72 57.8 53.3 51 64.7 46 56 - - 9.60 22.00 8.00 6.00 18x24 LIEBERT CW146D

AHU-105 B120 B120 18200 0.50 DIRECT - 4.2 460 3 60 3 302 302 72 57.8 53.3 51 64.7 46 56 - - 9.60 22.00 8.00 6.00 18x24 LIEBERT CW146D

AHU-106 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D

AHU-107 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D

AHU-108 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D

AHU-109 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D

AHU-400 B129 B120 1500 1.00 BELT 1500 1 480 3 60 1 41.1 41.1 93.6 60.5 72 53.6 8 45 55 116.70 7.00 18.80 55.00 13.00 2.00 16x16 CARRIER 39LC03

AIR HANDLING UNIT SCHEDULE

UNIT NO. CAPACITY WATER REMARKS

SUPPLY FAN DATA

AIR

COOLING COIL DATA KNOWN

ACCEPTIBLE

SOURCESLOCATION AREA

SERVICED ESP (IN

W.G.) DRIVE

HUMIDIFICATION

NOTE 1, 3

4. HUMIDIFIER IS EXTERNAL TO UNIT.

NOTE:

1. PROVIDE DOWN DISCHARGE UNITS WITH FLOOR STANDS, FACTORY INSTALLED DISCONNECT SWITCH, CONDENSATE PUMP, SMOKE DETECTOR, INFRARED TYPE HUMIDIFIER, AND FACTORY NETWORK CONTROLLER.

2. MATCH EXISTING UNITS (AHU-20,21,23) IN OPERATION AND CONFIGURATION OR PROVIDE APPROVED EQUAL.

NOTE 1, 3

NOTE 3, 4

3. UNITS SHALL UTILIZE FAN SETTINGS TO OBTAIN REQUIRED CFM AIR PROPERTIES AND TUNED GPM TO OBTAIN REQUIRED COOLING CAPACITY.

NOTE 1, 3

RPM

SUPPLY

AIR

(CFM)

NOTE 1, 3

NOTE 1, 3

SUPPLY FAN(S) MOTOR DATA

NOTE 1, 3

NOTE 1, 2, 3

FILTER SCHEDULE

MERV

EFF SIZEQTY

HEATING COIL DATA

GPM INLET

TEMP F

OUTLE

T TEMP PD CONN. GPM INLET

TEMP F

OUTLE

T TEMP PD CONN. LENGTH WEIGHT MFGR

HX-1 900 55 45 4.5 8" 1100 42 51 6.5 8" 5.75' 4700 SONDE

X

NOTE:

COMMENTS

CONSTRUCTION

DATA

KNOWN

ACCEPTABLE

MODEL/

SERIES

B116 CHILLED WATER

SYSTEM

150 PSI A65-IS10-212

HEAT EXCHANGER SCHEDULE

UNIT

NO. LOCATION SERVICE

MAX PRESS.

PERFORMANCE DATA CHILLED WATER PERFORMANCE DATA CONDENSER

WATER

FRAME

SUPPLY DRAIN AMPS VOLTS PH MFGR MODEL/ SERIES

DF-1 B134 DRINKING

FOUNTAIN 3/8" 1-1/2" 5 115 1 ELKAY EZH2O NOTE 1, 2

NOTE:

2. INCLUDE BOTTLE FILLING OPTION

COMMENTS

KNOWN ACCEPTABLE

SOURCE

DRINKING FOUNTAIN

UNIT

NO. DESCRIPTIONLOCATION

PLUMBING DATA ELECTRICAL DATA

1. MOUNTED 52" ABOVE FINISHED CONCRETE FLOOR (34" ABOVE RAISED FLOOR)

MFGR MODEL/ SERIES

CR-1 B88 PERFORATED

RETURN 18 X 18 20 X 20 LAY-IN 35 2000 TITUS PXP NOTE 1

CD-1 B88 MODULAR

SUPPLY DIFFUSER 12 X 12 24 X 24 LAY-IN 30 350 TITUS MCD NOTE 1

TG-1 B120A TRANSFER

GRILLE 20 X 16 20 X 16 SIDEWALL 40 650 KRUEGE

R 5600 NOTE 1

SR-1 B120A SIDEWALL

REGISTER 12 X 18 12 X 18 SIDEWALL 40 1400 HART &

COOLEY 92HVV NOTE 1

NOTE:

1. UNITS OF APPROVED EQUAL ARE ACCEPTABLE

COMMENTS

KNOWN ACCEPTABLE

SOURCE

AIR DEVICE SCHEDULE

UNIT

NO. TYPE & DUTY NECK SIZE (IN.) FACE

SIZE (IN.) CEILING TYPE MAX NC

LEVEL

MAX

CFMLOCATION

POINT DESCRIPTION NOTES

DE

VI

CE

C O

DE

SU

PE

RV

IS

ED

W

IR

IN

G

AN

AL

O G

IN

PU

T

DI

GI

TA

L

IN

PU

T

AD

DR

ES

SA

BL

E

IN

PU

T

AC

CU

M U

LA

TO

R

IN

PU

T

AN

AL

O G O U

TP

U T

ST

AT

E

DI

GI

TA

L O U

TP

U T

ST

AT

E

DI

GI

TA

L O U

TP

U T

AD

DR

ES

SA

BL

E O U

TP

U T

FA

IL

O N (O

PE

N

FA

IL

O

FF

(C

LO

SE

D)

LA

ST

C O M M

AN

D

ST

AT

E

LO

CA

L

DE

FA

U

LT

N

ET

W O

RK

P O

IN

T

CA

LC

U

LA

TE

D

PO

IN

T

M

AI

N

TE

N

AN

CE

A

LA

RM

CR

IT

IC

AL

A

LA

RM

PR

O

GR

AM

S

TA

RT

(S

TO

P)

O

PT

IM

U S

ST

AR

T (S

TO

P)

M O

RN

IN

G W

AR

M /C O O L

DE

M

AN

D

LI

M

IT

DU

TY

C

YC

LE

EN

TH

AL

PY

E

CO

N O M

IZ

ER

DI

RE

CT

D

IG

IT

AL

C O N

TR

O L

SE

T

PO

IN

T

AD

JU

ST

M

EN

T

TO

TA

LI

ZE

R

RU

N T

IM

E

LI

GH

TI

N G

CO

N

TR

O L

TE

N

AN

T

BI

LL

IN

G

AL

AR

M

IN

ST

RU

CT

IO

N S

M

AI

N

TE

N

AN

CE

W

O

RK

O

RD

ER

AL

AR

M L

IM

IT

S

SO

FT

W

AR

E

IN

TE

RL

O

CK

S

2‐ D

GR

AP

HI

CS

3‐ D

GR

AP

HI

CS

FL

O O R

PL

AN

PO

IN

T

LI

ST

LO

W L

IM

IT

HI

GH

L

IM

IT

CHILLED WATER SYSTEM ‐ NEW ● ● ●

(CH‐100, CH‐200, CH‐300, CH‐400 & P‐1A THRU P‐1D ●

CHILLER ENABLE/DISABLE ED ● ● ● TYPICAL FOR 4

CHILLER SET POINT ADJUSTMENT CI ● ● TYPICAL FOR 4

CHILLER TROUBLE/FAULT AX ● TYPICAL FOR 4

CHILLER AMPERAGE ‐ ● ● TYPICAL FOR 4

CHILLER POWER DEMAND (kW) ‐ ● ● TYPICAL FOR 4

CHILLER STATUS AX ● ● ● ● TYPICAL FOR 4

CHILLER CHW SUPPLY TEMPERATURE TS ● ● ● ● 40°F 50°F TYPICAL FOR 4

CHILLER CHW RETURN TEMPERATURE TS ● ● ● ● 50°F 60°F TYPICAL FOR 4

CHILLER CHW DP SWITCH PS ● ● ● TYPICAL FOR 4

CHILLER CHW FLOW METER FM ● ● ● TYPICAL FOR 4

CHILLER CW SUPPLY TEMPERATURE TS ● ● ● ● 60°F 90°F TYPICAL FOR 4

CHILLER CW RETURN TEMPERATURE TS ● ● ● ● 65°F 95°F TYPICAL FOR 4

CHILLER CW DP SWITCH PS ● ● ● TYPICAL FOR 4

CHILLER CW FLOW METER FM ● ● ● TYPICAL FOR 4

CHILLER CHW DIFFERENTIAL PRESSURE PD ● ● ● TYPICAL FOR 4

CHILLER CHW ISOLATION VALVE CONTROL CV ● ● ● ● ● TYPICAL FOR 4

CHILLER CHW ISOLATION VALVE POSITION VI ● ● ● TYPICAL FOR 4

CHILLER CW ISOLATION VALVE CONTROL CV ● ● ● ● ● TYPICAL FOR 4

CHILLER CW ISOLATION VALVE POSITION VI ● ● ● TYPICAL FOR 4

CHW PUMP START/STOP SS ● ● ● ● TYPICAL FOR 4

CHW PUMP STATUS AX ● ● ● ● TYPICAL FOR 4

CHW PUMP SPEED CONTROL CI ● ● ● TYPICAL FOR 4

CHW PUMP BYPASS STATUS AX ● ● ● ● TYPICAL FOR 4

REFRIFGERANT LEAK MONITORING SYSTEM ● ● ●

REFRIGERANT LEAK ALARM (LOW LEVEL ALARM) DC ● ● ●

REFRIGERANT LEAK ALARM (HIGH LEVEL ALARM) DC ● ● ●

RLMS PANEL FAULT/TROUBLE DC ● ● ●

REFRIGERANT LOW LEAK ALARM TO BAS AX ● ● ● ● OUTPUT FROM MONITOR

REFRIGERANT HIGH LEAK ALARM TO BAS AX ● ● ● ● OUTPUT FROM MONITOR

EXHAUST FAN (EF‐310) ● ● ●

EXHAUST FAN START/STOP SS ● ● ●

EXHAUST FAN STATUS CR ● ● ● ● ●

SPACE TEMPERATURE TS ● ‐ 90°F

OUTDOOR INTAKE DAMPER CONTROL CD ● ● ●

LOW EXHAUST DAMPER CONTROL CD ● ●

HIGH EXHAUST DAMPER CONTROL CD ●

SILENCE SWITCH DI ● ● ●

EMERG. VENTILATION SWITCH DI ● ● ●

CONDENSER WATER SYSTEM ‐ NEW ● ● ●

(CT‐1A THRU CT‐1C & P‐3A THRU P‐3C)

COOLING TOWER FAN START/STOP SS ● ● ● ● TYPICAL FOR 3

COOLING TOWER FAN STATUS AX ● ● ● ● TYPICAL FOR 3

COOLING TOWER FAN SPEED CONTROL CI ● ● ● TYPICAL FOR 3

COOLING TOWER FAN BYPASS MODE AX ● ● ● ● TYPICAL FOR 3

COOLING TOWER FAN OIL LEVEL ALARM DC ● ● ● TYPICAL FOR 3

COOLING TOWER FAN VIBRATION ALARM DC ● ● ● TYPICAL FOR 3

COOLING TOWER ISOLATION VALVE CONTROL CV ● ● ● ● TYPICAL FOR 3

COOLING TOWER ISOLATION VALVE POSITION VI ● ● ● TYPICAL FOR 3

CONDENSER WATER SUMP LEVEL LS ● ● ● TYPICAL FOR 4

CW/CT VFD START/STOP SS ● ● ● ● TYPICAL FOR 3

CW/CT PUMP STATUS AX ● ● ● ● TYPICAL FOR 3

CW/CT VFD FREQUENCY AO ● ● ● TYPICAL FOR 3

CW/CT VFD FAULT/ALARM DI

CW/CT VFD POWER OUTPUT AO

CW/CT VFD POWER USAGE AI

CW/CT PUMP BYPASS MODE AX ● ● ● ● TYPICAL FOR 3

CONDENSER WATER SUPPLY TMPERATURE TS ● ● ● ● 50°F 90°F

CONDENSER WATER RETURN TEMPERATURE TS ● ● ● ● 60°F 100°F

CONDENSER WATER LOOP DIFF. PRESSURE PD ● ● ● ● 10 PSI 20 PSI

CONDENSER WATER BYPASS VALVE CONTROL CV ● ● ●

CONDENSER WATER BYPASS VALVE POSITION VI ● ● ●

CW TREATMENT SYSTEM PUMP START/STOP (P‐4A) SS ● ● ● ●

CW TREATMENT SYSTEM PUMP STATUS (P‐4A) CR ● ● ● ●

MAKEUP WATER CONTROL VALVE CONTROL CV ● ● ● ●

MAKEUP WATER CONTROL VALVE POSITION VI ● ● ●

HEAT EXCHANGER ‐ NEW ● ● ●

HX FLOW METER FM ●

FCV 1C (CHILLED WATER) COMMAND FCV ● ●

FCV 1D (CONDENSER WATER) COMMAND FCV ● ●

FCV 1C (CHILLED WATER) FEEDBACK FCV ●

FCV 1D (CONDENSER WATER) FEEDBACK FCV ●

CW SUPPLY TEMP TS 1A TS ● ● 35°F ‐

CW RETURN TEMP TS 1B TS ● ● 35°F ‐

COND. SUPPLY TEMP TS 1C TS ● ● 35°F ‐

COND. RETURN TEMP TS 1D TS ● ● 35°F ‐

ALARM LIMITSHARDWARE FAIL MODE SOFTWARE GRAPHICS

POINT DESCRIPTION NOTES

DE

VI

CE

C O

DE

SU

PE

RV

IS

ED

W

IR

IN

G

AN

AL

O G

IN

PU

T

DI

GI

TA

L I N

PU

T

AD

DR

ES

SA

BL

E

IN

PU

T

AC

CU

M U

LA

TO

R

IN

PU

T

AN

AL

O G O U

TP

U T

ST

AT

E

DI

GI

TA

L O U

TP

U T

ST

AT

E

DI

GI

TA

L O U

TP

U T

AD

DR

ES

SA

BL

E O U

TP

U T

FA

IL

O N (O

PE

N

FA

IL

O

FF

(C

LO

SE

D)

LA

ST

C O M M

AN

D

ST

AT

E

LO

CA

L D

EF

AU

LT

N

ET

W O

RK

P O

IN

T

CA

LC

U

LA

TE

D

PO

IN

T

M

AI

N

TE

N

AN

CE

A

LA

RM

CR

IT

IC

AL

A

LA

RM

PR

O

GR

AM

S

TA

RT

(S

TO

P)

O

PT

IM

U S

ST

AR

T (S

TO

P)

M O

RN

IN

G W

AR

M /C O O L

DE

M

AN

D

LI

M

IT

DU

TY

C

YC

LE

EN

TH

AL

PY

E

CO

N O M

IZ

ER

DI

RE

CT

D

IG

IT

AL

C O N

TR

O L

SE

T

PO

IN

T

AD

JU

ST

M

EN

T

TO

TA

LI

ZE

R

RU

N T

IM

E

LI

GH

TI

N G

CO

N

TR

O L

TE

N

AN

T

BI

LL

IN

G

AL

AR

M

IN

ST

RU

CT

IO

N S

M

AI

N

TE

N

AN

CE

W

O

RK

O

RD

ER

AL

AR

M

LI

M

IT

S

SO

FT

W

AR

E

IN

TE

RL

O

CK

S

2‐ D

GR

AP

HI

CS

3‐ D

GR

AP

HI

CS

FL

O O R

PL

AN

PO

IN

T

LI

ST

LO

W

LI

M

IT

HI

GH

LI

M

IT

COMPUTER ROOM AIR CONDITIONERS ▪ ▪ ▪ TYPICAL FOR 5

AHU 104 THRU AHU 109 TYPICAL FOR 5

SUPPLY FAN START/STOP SS ▪ ▪ ▪ ▪ TYPICAL FOR 5

SUPPLY FAN STATUS CR ▪ ▪ ▪ ▪ ▪ TYPICAL FOR 5

SUPPLY FAN SPEED CONTROL CI ▪ ▪ ▪ TYPICAL FOR 5

SPACE TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 60°F 80°F TYPICAL FOR 5

SPACE HUMIDITY HS ▪ ▪ 35% 65% TYPICAL FOR 5

SUPPLY AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F TYPICAL FOR 5

RETURN AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F TYPICAL FOR 5

FILTER ALARM DP ▪ ▪ ▪ ▪ ▪ TYPICAL FOR 5

COOLING COIL CONTROL VALVE CV ▪ ▪ ▪ ▪ TYPICAL FOR 5

HUMIDIFIER ENABLE/DISABLE ED ▪ ▪ ▪ ▪ TYPICAL FOR 5

HUMIDIFIER CONTROL CI ▪ ▪ ▪ ▪ TYPICAL FOR 5

CONDENSATE PUMP ALARM AX ▪ ▪ ▪ ▪ TYPICAL FOR 5

COMPUTER ROOM AIR CONDITIONERS ▪ ▪ ▪

AHU 22

SUPPLY FAN START/STOP SS ▪ ▪ ▪ ▪

SUPPLY FAN STATUS CR ▪ ▪ ▪ ▪ ▪

SPACE TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 60°F 80°F

SPACE HUMIDITY HS ▪ ▪ 35% 65%

SUPPLY AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F

RETURN AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F

FILTER ALARM DP ▪ ▪ ▪ ▪

COOLING COIL CONTROL VALVE CV ▪ ▪ ▪ ▪

HEATING COIL CONTROL VALVE CV ▪ ▪ ▪ ▪

HUMIDIFIER ENABLE/DISABLE ED ▪ ▪ ▪ ▪

HUMIDIFIER CONTROL CI ▪ ▪ ▪ ▪

CONDENSATE PUMP ALARM AX ▪ ▪ ▪ ▪

OUTDOOR AIR HANDLING UNIT (AHU 400) ● ● ●

SUPPLY FAN START/STOP SS ● ● ●

SUPPLY FAN STATUS CR ● ● ● ●

SUPPLY AIR TEMPERATURE TS ● ● ● ● 50°F 80°F

SPACE HUMIDITY HS ● ● ● ● 35% 65%

SPACE TEMPERATURE TS ● ● ● ● 60°F 80°F

FREEZSTAT ALARM FZ ● ● ●

FILTER ALARM DP ● ● ●

COOLING COIL CONTROL VALVE CV ● ● ●

HEATING COIL CONTROL VALVE CV ● ● ●

HUMIDIFIER ENABLE/DISABLE ED ● ●

HUMIDIFIER CONTROL CI ● ● ●

HARDWARE FAIL MODE SOFTWARE GRAPHICS ALARM LIMITS

METHOD HEIGHT

RL 2X4 T5 RECESSED LITHONIA/COLUMBIA 2RT5 28T5 MVOLTGEB95 LPM835P PWS1836 T5 120/277 RECESSED ROOM B134 2-LAMP FIXTURE

RL1 2X4 T5 RECESSED W/ BATTERY PACK LITHONIA/COLUMBIA 2RT5 28T5 MVOLTGEB95 EL14 LPM835P PWS1836 T5 120/277 RECESSED ROOM B134 2-LAMP FIXTURE

EMERGENCY BATTERY PACK

P CREE LED SURFACE WRAP ESSENTIA/CREE S-WR4-40L-40K LED 120/277 PENDANT PUMP HOUSE &

CHILLER RMS COMPLIANT CLASS A OR B

P1 CREE LED SURFACE WRAP - EMERGENCY BACK UP ESSENTIA/CREE S-WR4-40L-40K-EB LED 120/277 PENDANT PUMP HOUSE &

CHILLER RMS EMERGENCY BATTERY PACK

S CREE LED SURFACE WRAP ESSENTIA/CREE S-WR4-40L-40K LED 120/277 SURFACE TELCO ROOMS

B101 & B102 COMPLIANT CLASS A OR B

S1 CREE LED SURFACE WRAP - EMERGENCY BACK UP ESSENTIA/CREE S-WR4-40L-40K-EB LED 120/277 SURFACE TELCO ROOMS

B101 & B102 EMERGENCY BATTERY PACK

R 2X4 LED RECESSED TROFFER LITHONIA/COLUMBIA 2GTL4 LP840 LED 120/277 RECESSED EOF B88 ROOM COMPLIANT CLASS A OR B

R1 2X4 LED RECESSED TROFFER -EMERGENCY BACK UP LITHONIA/COLUMBIA 2GTL4 LP840-EB LED 120/277 RECESSED EOF B88 ROOM EMERGENCY BATTERY PACK

W OUT DOOR WALL PACK LED LITHONIA/COLUMBIA ZIBO 40W LED LED 120/277 WALL

MOUNTED

COOLING

TOWER/PUMP 5700 K

EXIT

SIGN

SINGLE FACE WITH WHITE THERMAL PLASTIC HOUSING

AND FACE WITH RED LETTER

LITHONIA QUANTUM

SERIES LQMPS3R120.277ELN LED 120/277 WALL

MOUNTED

TELCO ROOMS

B101 & B102

INTEGRAL BATTERY &

CHARGE COMPLIANT CLASS A

NOTES:

LAMPS

LIGHTING FIXTURE SCHEDULE

TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLTS

FIXTURE MOUNTING

COMMENTSLOCATION

LENGTH WIDTH HEIGHT

MFGR MODEL/

SERIES

TCH-1 OUTDOORS CAMPUS AIR COOLED

CHILLER R-134a 400 830 55 45.0 790.0 11.9 25-125 372/432* 423/474* 500/600* 460 3 60 48 8.5 12.6 43,460 TRANE RTAC400 NOTE 1

TCH-2 OUTDOORS CAMPUS AIR COOLED

CHILLER R-134a 400 830 55 45.0 790.0 11.9 25-125 372/432* 423/474* 500/600* 460 3 60 48 8.5 12.6 43,460 TRANE RTAC400 NOTE 1

NOTES:

PH

UNIT

NUMBER WPD

(FT)

AMBIENT

OPERATING

CONDITIONS

(0F)

ELECTRICAL REQUIREMENTS

LOCATION CHARGE

(LBS)

FLA HZMCA MOP

NOTE 1: TWO CHILLERS WILL NEED TO BE FULLY POWERED AND PLUMBED TO THE BUILDING, AND 1 CHILLER WITH THE SAME PIPING CONFIGURATION AND SPECS WILL NEED TO BE ON STANDBY AT A RENTAL YARD, AND ABLE TO BE HOOKED UP AND RUNNING NO LONGER THAN 24 HOURS FOLLOWING

THE EVENT OF EITHER OF THE TWO CHILLERS ONSITE FAILING.

* DUAL POINT CONNECTION

TEMPORARY CHILLER SCHEDULE

SERVICE EQUIPMENT

TYPE REFRIGERANT

NOMINAL

CAPACITY

(TONS)

EVAPORATOR DATA DIMENSIONS (FT)

MAXIMUM WEIGHT

(LBS.) CHILLER AND

TRAILER

KNOWN

ACCEPTABLE

SOURCE

COMMENTS

EWT (0F) LWT (0F) FLOW

(GPM) VOLT

General
Drawing Index
Civil
Fencing
Architectural
Hazmat
Demolition
New Construction
Exterior Elevations
RCP
Details
Interior Elevations
Schedules
Structural
Details
Cooling Tower Platform
Mechanical
Demolition
New Construction
Sections and Details
Typical details
Schedules
Piping Diagrams
Demolition
New Construction

Control Diagrams

Electrical
Demolition
New Construction
Elevations
Details
Schedules
One Line Diagrams
Demolition
New Construction

Panel Schedules

Fire Suppression and Alarm
Fire Supression - Demolition
Fire Suppression - New Construction
Fire Alarm - Demolition
Fire Alarm - New Construction
Temporary Chillers
Seismic Restraints
Piping Diagram
Schedule
Electrical Diagrams
Lightning Protection