Attachment 1a - FINAL 100% Drawings 07-12-18.pdf
PDF 11 MB Posted
- Attached to
- AMENDMENT 0003: MAJOR MECHANICAL UPGRADES PROJECT AT FAA'S DENVER ARTCC FACILITY IN LONGMONT, CO
- Solicitation number
- 697DCK-18-R-00406
About this file
Attachment 1a - FINAL 100% Drawings 07-12-18 (pdf)
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WIDTH HEIGHT DEPTH JA
M
B
H
EA
D
TH
R
ES
H
O
LD
11 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 45 10 2, 3, 4, 5, 8 B102 TELCO M-14 D4 HM 3'-0" 7'-0" 1-3/4" RHR Exist AL 1 3, 4, 7, 8 Boiler B116 M-15 D6 HM 3'-0" 7'-0" 1-3/4" RHR Exist AL 5 4, 7, 8 Chiller B115
17 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 9 5, 10 MCCs B112 18 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 9 5, 10 B118 Vestibule 20 D1 HM PR 3'-0" 7'-0" 1-3/4" RHR F1 HM 45 6 1, 5, 6, 10 Chiller B115 22 D4 HM 3'-0" 7'-0" 1-3/4" LHR Exist 45 7 1, 2, 4, 5, 8 B118 Ramp
23 D4 HM PR 3'-0" 7'-0" 1-3/4" LHR F1 HM 45 8 3, 5, 8, 10 IT B102A
25 D1 HM PR 3'-0" 7'-0" 1-3/4" LH/RH Exist 45 4 3, 4, 5, 6, 8 B120
27 D4 HM 3'-0" 7'-0" 1-3/4" LH F1 HM 90 7 5, 8, 10 TELCO B101
30 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM X 90 2 3, 5, 8, 10 B88
35 F1 HM 90 5, 10 B120
36 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 45 8 2, 5, 8, 10 Mech. B129 37 D4 HM 3'-0" 7'-0" 1-3/4" LHR Exist 45 8 2, 4, 5, 8 Closet 40 D1 HM PR 2'-6" 7'-0" 1-3/4" LHR/RHR F1 HM 90 11 5, 6,8,9,10 Corridor B109 43 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 45 8 3, 5, 8, 10 Corridor B108 44 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 45 9 5, 10 Electrical B111 45 D2 HM PR 3'-0" 7'-0" 1-3/4" RHR Exist X 90 9 4, 5, 8 HOST Mech. B119
46 D4 HM 2'-0" 6'-8" 1-3/4" LHR F1 HM X 90 7 5, 8, 10 HOST B134
49 D3 HM 4'-0" 7'-0" 1-3/4" RHR Exist 90 8 3, 4, 5, 6, 8 HOST B134 50 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 45 6 3, 4, 5, 6, 8 HOST B134 51 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 90 3 3, 4, 5, 6, 8 B120A
52 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 4 3, 5, 6, 8, 10 B120A
53 D1 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR F1 HM 90 11 5, 6, 8, 9, 10 Corridor B109 56 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 90 9 2, 4, 5, 8 U-Chase 1 57 D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 90 9 2, 4, 5, 8 U-Chase 2
1ER D5 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 12 5, 7 To Elect. Addition 2ER D4 HM 3'-0" 7'-0" 1-3/4" RHR F1 HM 12 5, 7 To Elect. Addition 1PH D2 HM PR 3'-0" 7'-0" 1-3/4" LHR/RHR Exist 12 5, 7 To Pumphouse
4 D5 HM 3'-0" 7'-0" 1-3/4" RH Exist HM 4, 5, 8,11 Corridor B109 5 D3 HM 3'-0" 7'-0" 1-3/4" RHR F1 HM 90 17 5, 10 Corridor B109
6 D4 HM 3'-0" 7'-0" 1-3/4" LH F1 HM 90 8 5, 10 STAIR 1
12 D5 HM 3'-0" 7'-0" 1-3/4" RH Exist HM 4, 5, 8, 11 Corridor B109 13 D5 HM 3'-0" 7'-0" 1-3/4" LHR Exist HM 4, 5, 8, 11* Corridor B109 19 D4 HM 3'-0" 7'-0" 1-3/4" RH Exist 15 4, 5, 13 B118 41 D4 HM 2'-6" 7'-0" 1-3/4" LH Exist 90 16 4, 5 Corridor B109 54 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 90 13 4, 5, 10, 12 Corridor B109 55 D4 HM 3'-0" 7'-0" 1-3/4" LHR F1 HM 90 14 4, 5, 10 Corridor B109
1 D4 WD 2'-6" 4'-8" F1 WD 5 STAIR 1
EXC D3 HM 3'-6" 7'-0" F1 HM 5 B109 (EXERCISE)
TEL D4 HM 2'-0" 7'-0" F1 HM 5 B120 (TELCO)
11 Reuse existing hardare. *Replace closer only.
DOOR AND FRAME PAINTING ONLY (OPTION)
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A212 BASEMENT SOUTH
A212 BASEMENT SOUTH
A212 BASEMENT SOUTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A201 BOILER/CHILLER AREA
A201 BOILER/CHILLER AREA
DOOR, DOOR FRAME AND HARDWARE REPLACEMENT (OPTION)
Reuse Existing
DETAILS
FRAMEDOOR
NOMINAL SIZE
D O
O R
N O
TY
PE
M A
TE
R
IA
L
FI
R
E R
A
TI
N G
L A
B
EL
(M
IN
U
TE
S)
H A
R D
W A
R E
SE
T
N O
HANDING TYPE M
A
TE
R
IA
L
NOTE NUMBER
A211 BASEMENT NORTH
DRAWING REFERENCE
A201 BOILER/CHILLER AREA
ENTER TO ROOM
NUMBER(S) -
AREAS
A201 BOILER/CHILLER AREA
A211 BASEMENT NORTH
A201 BOILER/CHILLER AREA
A201 BOILER/CHILLER AREA
A201 BOILER/CHILLER AREA
DOOR SCHEDULE
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A212 BASEMENT SOUTH
A301 PUMPHOUSE
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A201 BOILER/CHILLER AREA
A201 BOILER/CHILLER AREA
A201 BOILER/CHILLER AREA
A201 BOILER/CHILLER AREA
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
A301 PUMPHOUSE
A301 PUMPHOUSE
A201 BOILER/CHILLER AREA
A212 BASEMENT SOUTH
A212 BASEMENT SOUTH
A212 BASEMENT SOUTH
A211 BASEMENT NORTH
A211 BASEMENT NORTH
Reuse existing closer and door stop. Replace lockset and hinges only.
DOOR SCHEDULE NOTES:
Reuse existing lockset and closer. Replace hinges only.
Connect to refrigerant leak detection system.
Reuse cast-in-place HM frame.
Coordinate with FAA's SSDI Contractor for door access control system.
Coordinate hardware with existing frame.
Paint doors and frames PT-3 unless noted otherwise.
Fire rated doors shall have fire rated safety glass.
Exterior insulated door.
May reuse existing frame.
These fire door(s) are normally open and shall be interfaced with the fire alarm control panel (FACP), and shall include appropriate releasing/hold-open devices and coordinating door hardware.
Replace with fire rated frame.
SPLICE LENGTH TABLE (4000PSI)
BAR SIZE
t < 12”, Ld
(INCHES)
t > 12”, Ld
(INCHES)
t < 12”, CLASS A
SPLICE,
LENGTH =
1.0Ld
(INCHES)
t < 12”, CLASS B
SPLICE,
LENGTH =
1.3Ld
(INCHES)
t > 12”, CLASS A
SPLICE,
LENGTH =
1.0Ld
(INCHES)
t > 12”, CLASS B
SPLICE,
LENGTH =
1.3Ld
(INCHES)
3 15 18 15 19 18 24 4 19 25 19 25 25 32 5 24 31 24 31 31 40 6 29 37 29 37 37 48 7 42 54 42 54 54 70 8 48 62 48 62 62 80 9 54 70 54 70 70 90 10 60 77 60 77 77 100 11 66 85 66 85 85 111
1. t = THICKNESS OF FRESH CONCRETE BELOW THE BOTTOM SURFACE OF A BAR
2. Ld = DEVELOPMENT LENGTH OF BAR
3. CLASS A SPLICE DOES NOT APPLY TO THIS PROJECT.
LOAD COMBINATION MAXIMUM REACTION TABLE (LBS)
FRAME
LINE
COL LINE
GRIDLINE LOAD ID H V COL LINE
GRIDLINE LOAD ID H V
1, 3 A 1 0 -693 B 1 0 -693
2 A 1 0 -1386 B 1 0 -1386
1, 3 A 2 0 -770 B 2 0 -770
2 A 2 0 -1540 B 2 0 -1540
1, 3 A 3 525 2136 B 3 525 35
2 A 3 1050 4274 B 3 1050 69
1, 3 A 4 0 -1216 B 4 0 -1217
2 A 4 0 -2433 B 4 0 -2433
1, 3 A 5 525 919 B 5 525 -1181
2 A 5 1050 1840 B 5 1050 -2364
HP
(EA.) VOLT PH MFGR MODEL/
SERIES
CT-1A 69.8 1,039 85.0 75.0 12.0 1 4 VARIABLE
SPEED 7.5 460 3 TOWER
TECH
TTXR-
041975
CT-1B 69.8 1,039 85.0 75.0 12.0 1 4 VARIABLE
SPEED 7.5 460 3 TOWER
TECH
TTXR-
041975
CT-1C 69.8 1,039 85.0 75.0 12.0 1 4 VARIABLE
SPEED 7.5 460 3 TOWER
TECH
TTXR-
041975
1. BASIS OF DESIGN IS TOWER TECH TTXR-041975.
RATED
CAPACITY
(TONS)
AIR
EWB
(°F) MAX
GPM
EWT
(°F)
LWT
(°F)
COOLING
TOWER YARD
MAXIMUM
WEIGHT
(LBS.)
KNOWN
ACCEPTABLE
SOURCE COMMENTS
COOLING TOWER SCHEDULE
STATIC
LIFT
(FT.)
CONDENSER WATER DATA
NO. OF
CELLS
NO. OF
FANS/
CELL SPEED
CONTROL
ELECTRICAL DATA
FAN AND MOTOR DATA
UNIT
NO. LOCATION SERVICE TYPE
NOTE 1, 2, 314,394360MECHANICAL DRAFT
COUNTER FLOW
CHILLERS
NOTES:
2. VIBRATION LIMIT SWITCH
3. SEE SHEET G002 FOR WIND LOADING.
NOTE 1, 2, 3
COOLING
TOWER YARD
CHILLERS MECHANICAL DRAFT
COUNTER FLOW
360 14,394 NOTE 1, 2, 3
COOLING
TOWER YARD
CHILLERS MECHANICAL DRAFT
COUNTER FLOW
360 14,394
TYPE QTY
(LBS.) TYPE MOUNT V PH HZ MFGR MODEL
CH-100 R-123 600 150 2 WATER 764 55.0 45.0 15.5 0.0001 150 2 WATER 904 75.0 85 18.3 0.00025 1 265 VAR
SPEED UNIT FIELD 185.9 314 500 460 3 60 TRANE CVHE
CH-200 R-123 600 150 2 WATER 764 55.0 45.0 15.5 0.0001 150 2 WATER 904 75.0 85 18.3 0.00025 1 265 VAR
SPEED UNIT FIELD 185.9 314 500 460 3 60 TRANE CVHE
UNIT
NO. LOCATION
RATED
CAPACITY
(TONS)
PART LOAD
EFFICIENCY/
IPLV (KW/TON)
REFRIDGERANT
EVAPORATOR DATA CONDENSER DATA
NO.
OF
PASS.
FLUID
TYPE
FLOW
RATE
(GPM)
PRESS
RATING
(PSIG)
NO.
OF
PASS.
FLUID
TYPE
FLOW
RATE
(GPM)
NO. OF
COMP.
FULL
LOAD
AMPS
(FLA)
EWT
(°F)
LWT
(°F)
MAX
PD
(FT.)
FOULING
FACTOR
PRESS
RATING
(PSIG)
COMMENTS
B115 320 0.3291 19,019 NOTES 1, 2
COMPRESSOR
DATA COMPRESSOR
MOTOR
CONTROLLER
POWER
CONN.
POWER
INPUT
(KW)
MIN.
CIRCUIT
AMPACITY
(A)
MAX
OCP
(A)
EWT
(°F)
LWT
(°F)
MAX
PD
(FT.)
FOULING
FACTOR
NOTES:
1. UNIT MUST MEET FEMP EFFICIENCY REQUIREMENTS
2. MARINE WATER BOX
CHILLER SCHEDULE - CENTRIFUGAL TYPE
FULL LOAD
EFFICIENCY(KW/
TON)
0.567
B115 320 0.567 0.3291 19,019 NOTES 1, 2
ELECTRICAL CHAR.
CHILLER ELECTRICAL REQUIREMENTS
MAXIMUM
WEIGHT (LBS)
KNOWN
ACCEPTABLE
SOURCE
VOLTS PH HZ
1000 150 1780 60 480 3 60
1000 150 1780 60 480 3 60
1000 150 1780 60 480 3 60
1000 150 1780 60 480 3 60
1100 110 1770 40 460 3 60
1100 110 1770 40 460 3 60
1100 110 1770 40 460 3 60
1. VARIABLE SPEED PUMP
2. 2-STAGE PUMP(TURBINES)
BELL & GOSSET VIT-DITM-12CMC NOTE 1, 2
P-3B PUMP HOUSE CONDENSER
WATER SYSTEM BELL & GOSSET VIT-DITM-12CMC NOTE 1, 2
P-3C PUMP HOUSE CONDENSER
WATER SYSTEM BELL & GOSSET
NOTES:
BELL & GOSSET HSC-S 6X8X12L NOTE 1
CHILLED WATER
SYSTEM
CHILLED WATER
SYSTEM
CHILLED WATER
SYSTEM
NOTE 1
BELL & GOSSET HSC-S 6X8X12L NOTE 1
BELL & GOSSET HSC-S 6X8X12L NOTE 1
PUMP SCHEDULE
COMMENTSGPM TDH
(FEET) RPM HP
ELECTRICAL DATA
UNIT NO. LOCATION SERVICE
KNOWN ACCEPTABLE SOURCE
MFGR MODEL/SERIES
VIT-DITM-12CMC NOTE 1, 2
P-1A B115 CHILLED WATER
SYSTEM
P-1B
P-1C
P-1D
P-3A CONDENSER
WATER SYSTEM
B115
B115
B115
PUMP HOUSE
BELL & GOSSET HSC-S 6X8X12L DIA IN LENGTH
IN
CAP
GAL
WATER 30 84 240TK-202 ATTIC DSR
MECH ROOM
CHILLED WATER
SYSTEM
DIAPHRAGM TYPE TANK
NOTES:
EXPANSION TANK SCHEDULE
REMARKSCONTENT
SIZE
UNIT NO. LOCATION SERVICE
TSP
(IN WG)
MAX OV
(FPM)
MAX
RPM
MAX
BHP HP VOLTS PH CLASS ROT. DISCH. ARRANG. DRIVE MFGR
EF-310 1,500
4,000 0.5 1800 600 0.89 1 480 3 - CW HORIZ. - BELT GREEN
HECK
EF-101A 990
VARIABLE - 1,700 - 1/3 115/230 1 - - HORIZ. - DIRECT CAN
ARM
EF-101B 580
690 - 1,600 - 1/20 115 1 - - HORIZ. - DIRECT CAN
ARM
SF-101 520 - 1725 - 1/4 115/230 1 - - HORIZ. - DIRECT AMERI
CRAFT
NOTE:
1. UNIT WITH MOTORIZED DAMPER.
2. UNIT WITH WIRE MESH SCREEN.
3. UNIT WITH 2-SPEED FAN
COMMENTS
CONSTRUCTION DATA KNOWN
ACCEPTABLE
MODEL/
SERIES
B116 CHILLER ROOM
EXHAUST
CENTRIFUGAL SFB-30 NOTE 1, 2, 3
PUMP
HOUSE
ELECTRICAL
ADDITION
INLINE
EXHAUST FAN SCHEDULE
UNIT
NO. LOCATION SERVICE CFM
PERFORMANCE DATA MOTOR DATA
TYPE FAN
S10-B2 NOTE 3
PUMP
HOUSE
PUMP HOUSE
EXHAUST
INLINE S12-EVD
PUMP
HOUSE
PUMP HOUSE
INTAKE
INLINE CAF-912-1/4
MFGR MODEL/
SERIES MFGR MODEL/
SERIES
FCV-1A B115 CH-100 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-2A B115 CH-200 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-3A B115 CH-300 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-4A B115 CH-400 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-1B B115 CH-100 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-2B B115 CH-200 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-3B B115 CH-300 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-4B B115 CH-400 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-1C B115 HX-1 8 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-1D B115 HX-1 8 904 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-5A COOLING
TOWER YARD CT-1A 10 904 5430 BUTTERFLY BRAY NYL2 120 3 2 POSITION BRAY S70
FCV-5B COOLING
TOWER YARD CT-1B 10 904 5430 BUTTERFLY BRAY NYL2 120 3 2 POSITION BRAY S70
FCV-5C COOLING
TOWER YARD CT-1C 10 904 5430 BUTTERFLY BRAY NYL2 120 3 2 POSITION BRAY S70
FCV-6 B113A CHILLED WATER
BYPASS 6 764 3316 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FCV-7 PUMP HOUSE COOLING
TOWER BYPASS 6 904 1850 BUTTERFLY BRAY NYL2 120 3 2-10 VDC BRAY S70
FLOW CONTROL VALVE SCHEDULE
VALVE DATA
UNIT NO. LOCATION SERVICE
DESIGN
PIPE SIZE
(IN.)
KNOWN SOURCE COMMENTSFLOW
COEFFICIENT
(Cv)
DESIGN
FLOW
(GPM)
TYPE
ACTUATOR DATA
VOLTS CONTROL
SIGNAL
KNOWN SOURCE
PH
NOTES:
TSP
(IN WG)
MAX OV
(FPM)
MAX
RPM
MAX
BHP
HP
AMPS VOLTS PH BTU/HR GPM MFGR MODEL/ SERIES
UH-315 B115 CHILLER ROOM
HEAT 1625 - - - 1/8 1/8
2.3 115 1 55,000 7 MODINE HC-108
EUH-1 PUMP
HOUSE
PUMP HOUSE
HEAT 830 - - - - N/A
18.7 480 3 51,000 - MODINE HER-150
EUH-2 PUMP
HOUSE
PUMP HOUSE
HEAT 830 - - - - N/A
15.7 480 3 42,700 - MODINE HER-125
NOTE:
COMMENTS
CONSTRUCTION DATA KNOWN ACCEPTABLE
SOURCE
UNIT HEATER SCHEDULE
UNIT
NO. LOCATION SERVICE CFM
PERFORMANCE DATA MOTOR DATA
CAPACITY WATER
HP VOLTS PH HZ # FANS TOTAL
(MBH)
SENS.
(MBH) EDB ( ̊F) EWB ( ̊F) LDB ( ̊F) LWB ( ̊F) GPM ENT ( ̊F) LWT ( ̊F) TOTAL (MBH) GPM KW LBS/HR MFGR. MODEL/
SERIES
AHU-22 B119 B134 9,000 0.50 BELT - 10 460 3 60 2 146.7 146.7 72 54.7 58.9 49 55 46 58.7 10.20 30.00 8.00 2,4 16X20,16X25 DATA
AIRE
DACD-
AHU-104 B120 B120 18200 0.50 DIRECT - 4.2 460 3 60 3 302 302 72 57.8 53.3 51 64.7 46 56 - - 9.60 22.00 8.00 6.00 18x24 LIEBERT CW146D
AHU-105 B120 B120 18200 0.50 DIRECT - 4.2 460 3 60 3 302 302 72 57.8 53.3 51 64.7 46 56 - - 9.60 22.00 8.00 6.00 18x24 LIEBERT CW146D
AHU-106 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D
AHU-107 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D
AHU-108 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D
AHU-109 B120 B120 15860 0.50 DIRECT - 4.2 460 3 60 3 226 226 72 57.8 56 52.1 50.1 46 56 - - 9.60 22.00 8.00 4.00 18x24 LIEBERT CW106D
AHU-400 B129 B120 1500 1.00 BELT 1500 1 480 3 60 1 41.1 41.1 93.6 60.5 72 53.6 8 45 55 116.70 7.00 18.80 55.00 13.00 2.00 16x16 CARRIER 39LC03
AIR HANDLING UNIT SCHEDULE
UNIT NO. CAPACITY WATER REMARKS
SUPPLY FAN DATA
AIR
COOLING COIL DATA KNOWN
ACCEPTIBLE
SOURCESLOCATION AREA
SERVICED ESP (IN
W.G.) DRIVE
HUMIDIFICATION
NOTE 1, 3
4. HUMIDIFIER IS EXTERNAL TO UNIT.
NOTE:
1. PROVIDE DOWN DISCHARGE UNITS WITH FLOOR STANDS, FACTORY INSTALLED DISCONNECT SWITCH, CONDENSATE PUMP, SMOKE DETECTOR, INFRARED TYPE HUMIDIFIER, AND FACTORY NETWORK CONTROLLER.
2. MATCH EXISTING UNITS (AHU-20,21,23) IN OPERATION AND CONFIGURATION OR PROVIDE APPROVED EQUAL.
NOTE 1, 3
NOTE 3, 4
3. UNITS SHALL UTILIZE FAN SETTINGS TO OBTAIN REQUIRED CFM AIR PROPERTIES AND TUNED GPM TO OBTAIN REQUIRED COOLING CAPACITY.
NOTE 1, 3
RPM
SUPPLY
AIR
(CFM)
NOTE 1, 3
NOTE 1, 3
SUPPLY FAN(S) MOTOR DATA
NOTE 1, 3
NOTE 1, 2, 3
FILTER SCHEDULE
MERV
EFF SIZEQTY
HEATING COIL DATA
GPM INLET
TEMP F
OUTLE
T TEMP PD CONN. GPM INLET
TEMP F
OUTLE
T TEMP PD CONN. LENGTH WEIGHT MFGR
HX-1 900 55 45 4.5 8" 1100 42 51 6.5 8" 5.75' 4700 SONDE
X
NOTE:
COMMENTS
CONSTRUCTION
DATA
KNOWN
ACCEPTABLE
MODEL/
SERIES
B116 CHILLED WATER
SYSTEM
150 PSI A65-IS10-212
HEAT EXCHANGER SCHEDULE
UNIT
NO. LOCATION SERVICE
MAX PRESS.
PERFORMANCE DATA CHILLED WATER PERFORMANCE DATA CONDENSER
WATER
FRAME
SUPPLY DRAIN AMPS VOLTS PH MFGR MODEL/ SERIES
DF-1 B134 DRINKING
FOUNTAIN 3/8" 1-1/2" 5 115 1 ELKAY EZH2O NOTE 1, 2
NOTE:
2. INCLUDE BOTTLE FILLING OPTION
COMMENTS
KNOWN ACCEPTABLE
SOURCE
DRINKING FOUNTAIN
UNIT
NO. DESCRIPTIONLOCATION
PLUMBING DATA ELECTRICAL DATA
1. MOUNTED 52" ABOVE FINISHED CONCRETE FLOOR (34" ABOVE RAISED FLOOR)
MFGR MODEL/ SERIES
CR-1 B88 PERFORATED
RETURN 18 X 18 20 X 20 LAY-IN 35 2000 TITUS PXP NOTE 1
CD-1 B88 MODULAR
SUPPLY DIFFUSER 12 X 12 24 X 24 LAY-IN 30 350 TITUS MCD NOTE 1
TG-1 B120A TRANSFER
GRILLE 20 X 16 20 X 16 SIDEWALL 40 650 KRUEGE
R 5600 NOTE 1
SR-1 B120A SIDEWALL
REGISTER 12 X 18 12 X 18 SIDEWALL 40 1400 HART &
COOLEY 92HVV NOTE 1
NOTE:
1. UNITS OF APPROVED EQUAL ARE ACCEPTABLE
COMMENTS
KNOWN ACCEPTABLE
SOURCE
AIR DEVICE SCHEDULE
UNIT
NO. TYPE & DUTY NECK SIZE (IN.) FACE
SIZE (IN.) CEILING TYPE MAX NC
LEVEL
MAX
CFMLOCATION
POINT DESCRIPTION NOTES
DE
VI
CE
C O
DE
SU
PE
RV
IS
ED
W
IR
IN
G
AN
AL
O G
IN
PU
T
DI
GI
TA
L
IN
PU
T
AD
DR
ES
SA
BL
E
IN
PU
T
AC
CU
M U
LA
TO
R
IN
PU
T
AN
AL
O G O U
TP
U T
ST
AT
E
DI
GI
TA
L O U
TP
U T
ST
AT
E
DI
GI
TA
L O U
TP
U T
AD
DR
ES
SA
BL
E O U
TP
U T
FA
IL
O N (O
PE
N
FA
IL
O
FF
(C
LO
SE
D)
LA
ST
C O M M
AN
D
ST
AT
E
LO
CA
L
DE
FA
U
LT
N
ET
W O
RK
P O
IN
T
CA
LC
U
LA
TE
D
PO
IN
T
M
AI
N
TE
N
AN
CE
A
LA
RM
CR
IT
IC
AL
A
LA
RM
PR
O
GR
AM
S
TA
RT
(S
TO
P)
O
PT
IM
U S
ST
AR
T (S
TO
P)
M O
RN
IN
G W
AR
M /C O O L
DE
M
AN
D
LI
M
IT
DU
TY
C
YC
LE
EN
TH
AL
PY
E
CO
N O M
IZ
ER
DI
RE
CT
D
IG
IT
AL
C O N
TR
O L
SE
T
PO
IN
T
AD
JU
ST
M
EN
T
TO
TA
LI
ZE
R
RU
N T
IM
E
LI
GH
TI
N G
CO
N
TR
O L
TE
N
AN
T
BI
LL
IN
G
AL
AR
M
IN
ST
RU
CT
IO
N S
M
AI
N
TE
N
AN
CE
W
O
RK
O
RD
ER
AL
AR
M L
IM
IT
S
SO
FT
W
AR
E
IN
TE
RL
O
CK
S
2‐ D
GR
AP
HI
CS
3‐ D
GR
AP
HI
CS
FL
O O R
PL
AN
PO
IN
T
LI
ST
LO
W L
IM
IT
HI
GH
L
IM
IT
CHILLED WATER SYSTEM ‐ NEW ● ● ●
(CH‐100, CH‐200, CH‐300, CH‐400 & P‐1A THRU P‐1D ●
CHILLER ENABLE/DISABLE ED ● ● ● TYPICAL FOR 4
CHILLER SET POINT ADJUSTMENT CI ● ● TYPICAL FOR 4
CHILLER TROUBLE/FAULT AX ● TYPICAL FOR 4
CHILLER AMPERAGE ‐ ● ● TYPICAL FOR 4
CHILLER POWER DEMAND (kW) ‐ ● ● TYPICAL FOR 4
CHILLER STATUS AX ● ● ● ● TYPICAL FOR 4
CHILLER CHW SUPPLY TEMPERATURE TS ● ● ● ● 40°F 50°F TYPICAL FOR 4
CHILLER CHW RETURN TEMPERATURE TS ● ● ● ● 50°F 60°F TYPICAL FOR 4
CHILLER CHW DP SWITCH PS ● ● ● TYPICAL FOR 4
CHILLER CHW FLOW METER FM ● ● ● TYPICAL FOR 4
CHILLER CW SUPPLY TEMPERATURE TS ● ● ● ● 60°F 90°F TYPICAL FOR 4
CHILLER CW RETURN TEMPERATURE TS ● ● ● ● 65°F 95°F TYPICAL FOR 4
CHILLER CW DP SWITCH PS ● ● ● TYPICAL FOR 4
CHILLER CW FLOW METER FM ● ● ● TYPICAL FOR 4
CHILLER CHW DIFFERENTIAL PRESSURE PD ● ● ● TYPICAL FOR 4
CHILLER CHW ISOLATION VALVE CONTROL CV ● ● ● ● ● TYPICAL FOR 4
CHILLER CHW ISOLATION VALVE POSITION VI ● ● ● TYPICAL FOR 4
CHILLER CW ISOLATION VALVE CONTROL CV ● ● ● ● ● TYPICAL FOR 4
CHILLER CW ISOLATION VALVE POSITION VI ● ● ● TYPICAL FOR 4
CHW PUMP START/STOP SS ● ● ● ● TYPICAL FOR 4
CHW PUMP STATUS AX ● ● ● ● TYPICAL FOR 4
CHW PUMP SPEED CONTROL CI ● ● ● TYPICAL FOR 4
CHW PUMP BYPASS STATUS AX ● ● ● ● TYPICAL FOR 4
REFRIFGERANT LEAK MONITORING SYSTEM ● ● ●
REFRIGERANT LEAK ALARM (LOW LEVEL ALARM) DC ● ● ●
REFRIGERANT LEAK ALARM (HIGH LEVEL ALARM) DC ● ● ●
RLMS PANEL FAULT/TROUBLE DC ● ● ●
REFRIGERANT LOW LEAK ALARM TO BAS AX ● ● ● ● OUTPUT FROM MONITOR
REFRIGERANT HIGH LEAK ALARM TO BAS AX ● ● ● ● OUTPUT FROM MONITOR
EXHAUST FAN (EF‐310) ● ● ●
EXHAUST FAN START/STOP SS ● ● ●
EXHAUST FAN STATUS CR ● ● ● ● ●
SPACE TEMPERATURE TS ● ‐ 90°F
OUTDOOR INTAKE DAMPER CONTROL CD ● ● ●
LOW EXHAUST DAMPER CONTROL CD ● ●
HIGH EXHAUST DAMPER CONTROL CD ●
SILENCE SWITCH DI ● ● ●
EMERG. VENTILATION SWITCH DI ● ● ●
CONDENSER WATER SYSTEM ‐ NEW ● ● ●
(CT‐1A THRU CT‐1C & P‐3A THRU P‐3C)
COOLING TOWER FAN START/STOP SS ● ● ● ● TYPICAL FOR 3
COOLING TOWER FAN STATUS AX ● ● ● ● TYPICAL FOR 3
COOLING TOWER FAN SPEED CONTROL CI ● ● ● TYPICAL FOR 3
COOLING TOWER FAN BYPASS MODE AX ● ● ● ● TYPICAL FOR 3
COOLING TOWER FAN OIL LEVEL ALARM DC ● ● ● TYPICAL FOR 3
COOLING TOWER FAN VIBRATION ALARM DC ● ● ● TYPICAL FOR 3
COOLING TOWER ISOLATION VALVE CONTROL CV ● ● ● ● TYPICAL FOR 3
COOLING TOWER ISOLATION VALVE POSITION VI ● ● ● TYPICAL FOR 3
CONDENSER WATER SUMP LEVEL LS ● ● ● TYPICAL FOR 4
CW/CT VFD START/STOP SS ● ● ● ● TYPICAL FOR 3
CW/CT PUMP STATUS AX ● ● ● ● TYPICAL FOR 3
CW/CT VFD FREQUENCY AO ● ● ● TYPICAL FOR 3
CW/CT VFD FAULT/ALARM DI
CW/CT VFD POWER OUTPUT AO
CW/CT VFD POWER USAGE AI
CW/CT PUMP BYPASS MODE AX ● ● ● ● TYPICAL FOR 3
CONDENSER WATER SUPPLY TMPERATURE TS ● ● ● ● 50°F 90°F
CONDENSER WATER RETURN TEMPERATURE TS ● ● ● ● 60°F 100°F
CONDENSER WATER LOOP DIFF. PRESSURE PD ● ● ● ● 10 PSI 20 PSI
CONDENSER WATER BYPASS VALVE CONTROL CV ● ● ●
CONDENSER WATER BYPASS VALVE POSITION VI ● ● ●
CW TREATMENT SYSTEM PUMP START/STOP (P‐4A) SS ● ● ● ●
CW TREATMENT SYSTEM PUMP STATUS (P‐4A) CR ● ● ● ●
MAKEUP WATER CONTROL VALVE CONTROL CV ● ● ● ●
MAKEUP WATER CONTROL VALVE POSITION VI ● ● ●
HEAT EXCHANGER ‐ NEW ● ● ●
HX FLOW METER FM ●
FCV 1C (CHILLED WATER) COMMAND FCV ● ●
FCV 1D (CONDENSER WATER) COMMAND FCV ● ●
FCV 1C (CHILLED WATER) FEEDBACK FCV ●
FCV 1D (CONDENSER WATER) FEEDBACK FCV ●
CW SUPPLY TEMP TS 1A TS ● ● 35°F ‐
CW RETURN TEMP TS 1B TS ● ● 35°F ‐
COND. SUPPLY TEMP TS 1C TS ● ● 35°F ‐
COND. RETURN TEMP TS 1D TS ● ● 35°F ‐
ALARM LIMITSHARDWARE FAIL MODE SOFTWARE GRAPHICS
POINT DESCRIPTION NOTES
DE
VI
CE
C O
DE
SU
PE
RV
IS
ED
W
IR
IN
G
AN
AL
O G
IN
PU
T
DI
GI
TA
L I N
PU
T
AD
DR
ES
SA
BL
E
IN
PU
T
AC
CU
M U
LA
TO
R
IN
PU
T
AN
AL
O G O U
TP
U T
ST
AT
E
DI
GI
TA
L O U
TP
U T
ST
AT
E
DI
GI
TA
L O U
TP
U T
AD
DR
ES
SA
BL
E O U
TP
U T
FA
IL
O N (O
PE
N
FA
IL
O
FF
(C
LO
SE
D)
LA
ST
C O M M
AN
D
ST
AT
E
LO
CA
L D
EF
AU
LT
N
ET
W O
RK
P O
IN
T
CA
LC
U
LA
TE
D
PO
IN
T
M
AI
N
TE
N
AN
CE
A
LA
RM
CR
IT
IC
AL
A
LA
RM
PR
O
GR
AM
S
TA
RT
(S
TO
P)
O
PT
IM
U S
ST
AR
T (S
TO
P)
M O
RN
IN
G W
AR
M /C O O L
DE
M
AN
D
LI
M
IT
DU
TY
C
YC
LE
EN
TH
AL
PY
E
CO
N O M
IZ
ER
DI
RE
CT
D
IG
IT
AL
C O N
TR
O L
SE
T
PO
IN
T
AD
JU
ST
M
EN
T
TO
TA
LI
ZE
R
RU
N T
IM
E
LI
GH
TI
N G
CO
N
TR
O L
TE
N
AN
T
BI
LL
IN
G
AL
AR
M
IN
ST
RU
CT
IO
N S
M
AI
N
TE
N
AN
CE
W
O
RK
O
RD
ER
AL
AR
M
LI
M
IT
S
SO
FT
W
AR
E
IN
TE
RL
O
CK
S
2‐ D
GR
AP
HI
CS
3‐ D
GR
AP
HI
CS
FL
O O R
PL
AN
PO
IN
T
LI
ST
LO
W
LI
M
IT
HI
GH
LI
M
IT
COMPUTER ROOM AIR CONDITIONERS ▪ ▪ ▪ TYPICAL FOR 5
AHU 104 THRU AHU 109 TYPICAL FOR 5
SUPPLY FAN START/STOP SS ▪ ▪ ▪ ▪ TYPICAL FOR 5
SUPPLY FAN STATUS CR ▪ ▪ ▪ ▪ ▪ TYPICAL FOR 5
SUPPLY FAN SPEED CONTROL CI ▪ ▪ ▪ TYPICAL FOR 5
SPACE TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 60°F 80°F TYPICAL FOR 5
SPACE HUMIDITY HS ▪ ▪ 35% 65% TYPICAL FOR 5
SUPPLY AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F TYPICAL FOR 5
RETURN AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F TYPICAL FOR 5
FILTER ALARM DP ▪ ▪ ▪ ▪ ▪ TYPICAL FOR 5
COOLING COIL CONTROL VALVE CV ▪ ▪ ▪ ▪ TYPICAL FOR 5
HUMIDIFIER ENABLE/DISABLE ED ▪ ▪ ▪ ▪ TYPICAL FOR 5
HUMIDIFIER CONTROL CI ▪ ▪ ▪ ▪ TYPICAL FOR 5
CONDENSATE PUMP ALARM AX ▪ ▪ ▪ ▪ TYPICAL FOR 5
COMPUTER ROOM AIR CONDITIONERS ▪ ▪ ▪
AHU 22
SUPPLY FAN START/STOP SS ▪ ▪ ▪ ▪
SUPPLY FAN STATUS CR ▪ ▪ ▪ ▪ ▪
SPACE TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 60°F 80°F
SPACE HUMIDITY HS ▪ ▪ 35% 65%
SUPPLY AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F
RETURN AIR TEMPERATURE TS ▪ ▪ ▪ ▪ ▪ 50°F 80°F
FILTER ALARM DP ▪ ▪ ▪ ▪
COOLING COIL CONTROL VALVE CV ▪ ▪ ▪ ▪
HEATING COIL CONTROL VALVE CV ▪ ▪ ▪ ▪
HUMIDIFIER ENABLE/DISABLE ED ▪ ▪ ▪ ▪
HUMIDIFIER CONTROL CI ▪ ▪ ▪ ▪
CONDENSATE PUMP ALARM AX ▪ ▪ ▪ ▪
OUTDOOR AIR HANDLING UNIT (AHU 400) ● ● ●
SUPPLY FAN START/STOP SS ● ● ●
SUPPLY FAN STATUS CR ● ● ● ●
SUPPLY AIR TEMPERATURE TS ● ● ● ● 50°F 80°F
SPACE HUMIDITY HS ● ● ● ● 35% 65%
SPACE TEMPERATURE TS ● ● ● ● 60°F 80°F
FREEZSTAT ALARM FZ ● ● ●
FILTER ALARM DP ● ● ●
COOLING COIL CONTROL VALVE CV ● ● ●
HEATING COIL CONTROL VALVE CV ● ● ●
HUMIDIFIER ENABLE/DISABLE ED ● ●
HUMIDIFIER CONTROL CI ● ● ●
HARDWARE FAIL MODE SOFTWARE GRAPHICS ALARM LIMITS
METHOD HEIGHT
RL 2X4 T5 RECESSED LITHONIA/COLUMBIA 2RT5 28T5 MVOLTGEB95 LPM835P PWS1836 T5 120/277 RECESSED ROOM B134 2-LAMP FIXTURE
RL1 2X4 T5 RECESSED W/ BATTERY PACK LITHONIA/COLUMBIA 2RT5 28T5 MVOLTGEB95 EL14 LPM835P PWS1836 T5 120/277 RECESSED ROOM B134 2-LAMP FIXTURE
EMERGENCY BATTERY PACK
P CREE LED SURFACE WRAP ESSENTIA/CREE S-WR4-40L-40K LED 120/277 PENDANT PUMP HOUSE &
CHILLER RMS COMPLIANT CLASS A OR B
P1 CREE LED SURFACE WRAP - EMERGENCY BACK UP ESSENTIA/CREE S-WR4-40L-40K-EB LED 120/277 PENDANT PUMP HOUSE &
CHILLER RMS EMERGENCY BATTERY PACK
S CREE LED SURFACE WRAP ESSENTIA/CREE S-WR4-40L-40K LED 120/277 SURFACE TELCO ROOMS
B101 & B102 COMPLIANT CLASS A OR B
S1 CREE LED SURFACE WRAP - EMERGENCY BACK UP ESSENTIA/CREE S-WR4-40L-40K-EB LED 120/277 SURFACE TELCO ROOMS
B101 & B102 EMERGENCY BATTERY PACK
R 2X4 LED RECESSED TROFFER LITHONIA/COLUMBIA 2GTL4 LP840 LED 120/277 RECESSED EOF B88 ROOM COMPLIANT CLASS A OR B
R1 2X4 LED RECESSED TROFFER -EMERGENCY BACK UP LITHONIA/COLUMBIA 2GTL4 LP840-EB LED 120/277 RECESSED EOF B88 ROOM EMERGENCY BATTERY PACK
W OUT DOOR WALL PACK LED LITHONIA/COLUMBIA ZIBO 40W LED LED 120/277 WALL
MOUNTED
COOLING
TOWER/PUMP 5700 K
EXIT
SIGN
SINGLE FACE WITH WHITE THERMAL PLASTIC HOUSING
AND FACE WITH RED LETTER
LITHONIA QUANTUM
SERIES LQMPS3R120.277ELN LED 120/277 WALL
MOUNTED
TELCO ROOMS
B101 & B102
INTEGRAL BATTERY &
CHARGE COMPLIANT CLASS A
NOTES:
LAMPS
LIGHTING FIXTURE SCHEDULE
TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLTS
FIXTURE MOUNTING
COMMENTSLOCATION
LENGTH WIDTH HEIGHT
MFGR MODEL/
SERIES
TCH-1 OUTDOORS CAMPUS AIR COOLED
CHILLER R-134a 400 830 55 45.0 790.0 11.9 25-125 372/432* 423/474* 500/600* 460 3 60 48 8.5 12.6 43,460 TRANE RTAC400 NOTE 1
TCH-2 OUTDOORS CAMPUS AIR COOLED
CHILLER R-134a 400 830 55 45.0 790.0 11.9 25-125 372/432* 423/474* 500/600* 460 3 60 48 8.5 12.6 43,460 TRANE RTAC400 NOTE 1
NOTES:
PH
UNIT
NUMBER WPD
(FT)
AMBIENT
OPERATING
CONDITIONS
(0F)
ELECTRICAL REQUIREMENTS
LOCATION CHARGE
(LBS)
FLA HZMCA MOP
NOTE 1: TWO CHILLERS WILL NEED TO BE FULLY POWERED AND PLUMBED TO THE BUILDING, AND 1 CHILLER WITH THE SAME PIPING CONFIGURATION AND SPECS WILL NEED TO BE ON STANDBY AT A RENTAL YARD, AND ABLE TO BE HOOKED UP AND RUNNING NO LONGER THAN 24 HOURS FOLLOWING
THE EVENT OF EITHER OF THE TWO CHILLERS ONSITE FAILING.
* DUAL POINT CONNECTION
TEMPORARY CHILLER SCHEDULE
SERVICE EQUIPMENT
TYPE REFRIGERANT
NOMINAL
CAPACITY
(TONS)
EVAPORATOR DATA DIMENSIONS (FT)
MAXIMUM WEIGHT
(LBS.) CHILLER AND
TRAILER
KNOWN
ACCEPTABLE
SOURCE
COMMENTS
EWT (0F) LWT (0F) FLOW
(GPM) VOLT
| General |
| Drawing Index |
| Civil |
| Fencing |
| Architectural |
| Hazmat |
| Demolition |
| New Construction |
| Exterior Elevations |
| RCP |
| Details |
| Interior Elevations |
| Schedules |
| Structural |
| Details |
| Cooling Tower Platform |
| Mechanical |
| Demolition |
| New Construction |
| Sections and Details |
| Typical details |
| Schedules |
| Piping Diagrams |
| Demolition |
| New Construction |
Control Diagrams
| Electrical |
| Demolition |
| New Construction |
| Elevations |
| Details |
| Schedules |
| One Line Diagrams |
| Demolition |
| New Construction |
Panel Schedules
| Fire Suppression and Alarm |
| Fire Supression - Demolition |
| Fire Suppression - New Construction |
| Fire Alarm - Demolition |
| Fire Alarm - New Construction |
| Temporary Chillers |
| Seismic Restraints |
| Piping Diagram |
| Schedule |
| Electrical Diagrams |
| Lightning Protection |
File details come from the government source that posted it.