Text version
TITLE SHEET
4 3 2
DTFAEN-16-C-00329
prohibited.
T-80-6
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
D
ES
C R
IP
TI
O N
L L
AP
D
C H
K
SS
BY
0/
/1
D
AT
E
W C
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
ACCORDANCE WITH THE CURRENT EDITIONS OF ALL GOVERNING CODES
W ed ne sd ay , O ct ob er
9, 4:
:1
PM
80 FT. ANTENNA TOWER, 6 MOUNTS
CONSTRUCTION:
T-80-6 TITLE SHEET
80 FT. ANTENNA TOWER, 6 MOUNTS
TOWER DESCRIPTION:
CA-00525-01 PARTS LIST
CA-00524-01-2 PARTS LIST
FEDERAL AVIATION ADMINISTRATION
STRUCTURAL:
TOWER OWNER:
F-80 FOUNDATION DETAILS
FOUNDATION:
THESE CODES.
CA-00524-01-1 PARTS LIST
DATE
CA-00528-05 PARTS LIST
DETAILS:
ENGINEER/FABRICATOR:
STRUCTURAL COMPONENTS, LLC
nXgen COMMUNICATIONS
INSTALLATION DRAWINGS FOR
LESSEE
CONSTRUCTION
(AS-BUILT)
ZONING/
(703) 226-8025
PROJECT SUMMARY SHEET INDEX
PERMITTING
PRE CONSTRUCTION
GN-1 GENERAL CONSTRUCTION NOTES
ARCHITECTURAL:
Z:
\J ob s\
Nx ge n\
DT
FA
EN
-1 6-
R-
2-
FA
A
To w er s
- N A\
T ow er s W or kin g\ In st al la tio n Se ts \S ol id w or ks
PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO (703) - 226-8025
SIGNATURE DISCIPLINE
APPROVALS
CONSULTANTS:
CONTRACTORS:
TBD.
INSPECTION
AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE
CA-00527-05 PARTS LIST
S-80-6 SPECIFICATIONS
CA-00522-04 PARTS LIST
CA-00523-08 PARTS LIST
CA-00523-03 PARTS LIST
CA-00523-02 PARTS LIST
CA-00523-01 PARTS LIST
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
CODE COMPLIANCE
D-T8-1 INSTALLATION DETAILS
D-T8-2 INSTALLATION DETAILS
D-T3 INSTALLATION DETAILS
D-T2 INSTALLATION DETAILS
D-T1 INSTALLATION DETAILS
D-P1 INSTALLATION DETAILS
D-P2 INSTALLATION DETAILS
D-P3 INSTALLATION DETAILS
D-M6-1 MOUNT DETAILS
D-M6-2 MOUNT DETAILS
D-L80 LADDER DETAILS
D-DG DYNA-GLIDE DETAILS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
CONSTRUCTION NOTES
DTFAEN-16-C-00329
5 4 3 prohibited.
relates to the client named is strictly
SS
GN-1
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
L L
AP
D
C H
K
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/
4/
D
AT
E D
ES
C
R
IP
TI
O
N
BY
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which
GENERAL
N O
GENERAL NOTES:
1. THE TOWER OUTLINED IN THESE DOCUMENTS WAS DESIGNED IN ACCORDANCE WITH THE TIA-222-G TOWER
CODE.
2. PLANS, SECTIONS, AND DETAILS ARE NOT TO BE SCALED FOR DETERMINATION OF QUANTITIES, LENGTHS, OR
FIT OF MATERIALS.
3. UNLESS NOTED OTHERWISE = U.N.O.
4. ALL WORK ON THESE DRAWINGS SHALL BE PERFORMED BY A QUALIFIED CONTRACTOR WITH A MINIMUM OF 5
YEARS OF PAST TOWER EXPERIENCE AND SHALL FOLLOW THE DICTATES OF GOOD CONSTRUCTION PRACTICE WITH WORKING KNOWLEDGE OF THE TIA CODE “STRUCTURAL STANDARD FOR ANTENNA SUPPORTING
STRUCTURES AND ANTENNAS”.
5. CONTRACTOR AND/OR SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR ANY PERMITTING REQUIRED OR PROVIDE PROOF THAT THE LOCAL JURISDICTION DOES NOT REQUIRE A PERMIT FOR THE WORK COMPLETED.
6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND OSHA SAFETY REGULATIONS AND PERFORMED UNDER NORMAL WEATHER CONDITIONS WITH WINDS NOT IN EXCESS OF 20
MPH.
7. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING EQUIPMENT, ANTENNAS, TX AND STRUCTURES. THE CONTRACTOR IS ALSO RESPONSIBLE FOR THE PROTECTION OF WORKERS, PUBLIC
AND PRIVATE PROPERTY DURING CONSTRUCTION UP UNTIL COMPLETION OF WORK.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL MEASUREMENTS AT THE SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE FOR COMPENSATIONS SHALL BE ALLOWED DUE TO DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED ON THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN THE DIMENSION WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER/CLIENT FOR CONSIDERATIONS BEFORE THE CONTRACTOR PROCEEDS WITH THE
WORK IN THE AFFECTED AREA.
9. ALL TOWER MATERIALS TO BE PROVIDED BY nXgen COMMUNICATIONS.
10. CONTRACTOR’S PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESS TO ANY EXISTING
OPERATIONAL AND SAFETY EQUIPMENT.
11. CONTRACTOR SHALL PROMPTLY REMOVE ANY AND ALL DEBRIS FROM SITE AND RESTORE AS BEST AS POSSIBLE
TO PRECONSTRUCTION CONDITION INCLUDING BUT NOT LIMITED TO ANY DIVOTS ON ROADWAY OR
SURROUNDING AREA.
12. DIGITAL PHOTOGRAPHS SHALL BE TAKEN OF SITE ACCESS, COMPOUND AND TOWER PRIOR TO CONSTRUCTION, DURING CONSTRUCTION AND POST CONSTRUCTION INCLUDING BUT NOT LIMITED TO ALL REINFORCED AREAS.
CLOSE-OUT REPORT SHALL FOLLOW WITHIN 3 BUSINESS DAYS.
PARTS / FABRICATION / SHOP DRAWINGS:
1. ALL PARTS INCLUDED IN THESE DRAWINGS ARE MANUFACTURED AND OR SUPPLIED BY STRUCTURAL
COMPONENTS, LLC. PARTS FROM OTHER MANUFACTURER’S ARE NOT TO BE USED UNLESS OTHERWISE
AUTHORIZED BY THE STRUCTURAL ENGINEER OF RECORD.
2. ALL FABRICATION / SHOP DRAWINGS ARE TO BE REVIEWED FOR COMPLIANCE TO THE STRUCTURAL DRAWINGS
AND SIGNED OFF BY THE STRUCTURAL ENGINEER PRIOR TO FABRICATION.
EARTHWORK:
1. THE STRUCTURAL DRAWINGS ILLUSTRATE THE COMPLETED FOUNDATION WITH ALL ELEMENTS IN THEIR FINAL
POSITIONS, PROPERLY SUPPORTED AND BRACED.
2. THE CONTRACTOR, IN THE PROPER SEQUENCE, SHALL PROVIDE SHORING AND BRACING AS MAY BE REQUIRED
DURING CONSTRUCTION TO ACHIEVE THE FINAL COMPLETED STRUCTURE.
3. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE
SHORING AND BRACING ELEMENTS.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL MISCELLANEOUS SHORING, BRACING, ETC. NECESSARY TO PROVIDE A COMPLETE AND STABLE STRUCTURE AS SHOWN ON THESE
DRAWINGS. CONSULT GEOTECH REPORT FOR FURTHER RECOMMENDATIONS.
5. CONTRACTOR’S PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESS TO ANY EXISTING
OPERATIONAL AND SAFETY EQUIPMENT.
FOUNDATION DESIGN:
1. FOUNDATION DESIGN BASED ON ALLOWABLE BEARING OF 2 KSF, 110 PSF SOIL WEIGHT AND AN INTERNAL
ANGLE OF FRICTION OF 30 DEGREES.
2. CONTRACTOR SHALL VERIFY THAT THE SOILS ENCOUNTERED CORRESPOND TO THE DESIGN PARAMETERS
WHILE EXCAVATING. THE CONTRACTOR SHALL CONTACT THE ENGINEER OF RECORD IF ANY UNEXPECTED SOILS
ARE ENCOUNTERED.
3. ALL FILL SHALL BE CLEAN AND FREE OF ORGANIC OR FROZEN SOILS AND FOREIGN MATERIALS. STRUCTURAL BACKFILL SHALL BE COMPACTED IN 12 INCH LOOSE LIFTS TO 97% OF MAXIMUM DRY DENSITY WITHIN 3% OF
OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698.
4. LOOSE MATERIAL SHALL BE REMOVED FROM BOTTOM OF EXCAVATION PRIOR TO PLACING CONCRETE.
5. CONCRETE SHALL BE PLACED AS SOON AS PRACTICAL AFTER EXCAVATION TO AVOID DISTURBANCE OF BEARING
AND SIDE WALL SURFACES.
6. FOLLOW ALL RECOMMENDATIONS IN GEOTECHNICAL REPORT FOR SUB-GRADE PREPARATION UNDER
FOUNDATION ELEMENTS.
CAST-IN-PLACE CONCRETE:
1. ALL CONCRETE DESIGN IS BASED ON THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI
3L8-11/318R-11).
2. ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3,000 PSI AND A
MAXIMUM SLUMP OF 4”. U.N.O.
3. CONCRETE SHALL BE PROPORTIONED UTILIZING TYPE II CEMENT. CONCRETE SUSCEPTIBLE TO FREEZING SHALL
BE FORMULATED FOR MAXIMUM FROST RESISTANCE IN ACCORDANCE WITH THE ACI MANUAL OF CONCRETE
PRACTICE.
4. COLD WEATHER AND/OR HOT WEATHER CONCRETING PROCEDURES SHALL BE PROVIDED, IF CONDITIONS
WARRANT, AS RECOMMENDED IN THE ACI MANUAL OF CONCRETE PRACTICE.
5. ALL ANCHOR BOLTS IN NEW FOUNDATIONS SHALL BE PLACED WITH SETTING TEMPLATES.
REINFORCING STEEL:
1. ALL DETAILING, FABRICATION, AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE
ACI MANUAL OF CONCRETE PRACTICE.
2. REINFORCING BARS SHALL BE DEFORMED AND CONFORM TO ASTM A615-79 AND SHALL BE GRADE 60, EXCEPT
TIES WHICH MAY BE GRADE 40.
3. AT REINFORCING STEEL SPLICES IN CONCRETE, LAP BARS 40 DIAMETERS FOR SIZES UNDER #7 AND 48
DIAMETERS FOR SIZES #7 AND LARGER U.N.O.
4. EXCEPT AS NOTED ON THE DRAWINGS, MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE IN
ACCORDANCE WITH ACI 318-05/318R-05.
5. NO.5 OR LARGER REINFORCING BARS SHALL NOT BE RE-BENT WITHOUT APPROVAL BY THE STRUCTURAL
ENGINEER.
6. WELDING OF REBAR IS STRICTLY PROHIBITED.
BACKFILLING:
1. BACKFILLING OF SOILS AROUND FOUNDATION BASES / ANCHORS SHALL BE COMPLETED BEFORE ERECTION OF
TOWER BEGINS.
2. BACKFILL SHALL BE COMPACTED IN LIFTS TO 90% COMPACTION.
3. BACKFILL SHALL BE NATIVE SOILS; IMPORTED FILL SHALL BE VERIFIED WITH THE GEOTECHNICAL ENGINEER
AND STRUCTURAL ENGINEER PRIOR TO BACKFILLING.
STRUCTURAL STEEL:
1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH 2010 AISC
SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, 2010 AISC CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES AND CHAPTER 4 OF THE TIA CODE.
2. PRE-QUALIFIED STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING MINIMUM GRADES (SEE FABRICATION
DRAWINGS FOR SPECIFIC GRADES FOR SPECIFIC PARTS):
CHANNELS, SOLID ROUND, & ANGLES ------ ASTM A36, (FY = 36 KSI)
PLATES ---------------------------------------------- A572 GR. 50, (FY = 50 KSI)
TOWER LEGS --------------------------------------- A572-50 (FY = 50 KSI)
ANGLE BRACING > 4” ----------------------------- A572-50 (FY = 50 KSI)
ANGLE BRACING < 4” ----------------------------- A36 (FY = 36 KSI)
ANCHOR BOLTS ------------------------------------ A193-B7 (FY = 105 KSI)
HSS -------------------------------------------------- ASTM A500 GR. B, (FY = 46 KSI) STEEL PIPE ----------------------------------------- ASTM A53 GR. B, (FY = 36 KSI) U-BOLTS -------------------------------------------- ASTM A307, (FY = 36 KSI) w/ LOCKING DEVICE U.N.O.
SEE TABLE 5-1 OF THE TIA CODE FOR ADDITIONAL SHAPES AND STANDARDS THAT ARE NOT LISTED
ABOVE.
3. NON PRE QUALIFIED STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING STANDARDS AS PER THE TIA
CODE:
THE CARBON EQUIVALENT OF STEEL SHALL NOT EXCEED 0.65 PER SECTION 5.4.2 OF THE TIA CODE
ELONGATION OF STEEL SHALL NOT BE LESS THAN 18%
TEST REPORTS SHALL BE IN ACCORDANCE WITH ASTM A6 OR A568
TOLERANCES SHALL BE IN ACCORDANCE WITH ASTM A6
4. FIELD CUT EDGES, EXCEPT DRILLED HOLES, SHALL BE GROUND SMOOTH.
CORROSION CONTROL:
1. ALL STEEL MEMBERS SHALL HAVE CORROSION CONTROL AS OUTLINED IN THE TIA CODE AND STATED BELOW:
STEEL MEMBERS SHALL BE HOT DIPPED GALVANIZED PER ASTM A123.
FASTENERS AND HARDWARE SHALL BE HOT DIPPED GALVANIZED PER ASTM A153 OR ASTM B695 CLASS 50
ALL REPAIRS SHALL BE PROTECTED IN ACCORDANCE WITH ASTM A780.
2. ALL FIELD CUT SURFACES SHALL BE REPAIRED WITH (2) COATS OF A 95% ZINC RICH PAINT PER ASTM A780
(ZRC PREFERRED).
3. ALL DAMAGED SURFACES, WELDED AREAS AND AUTHORIZED NON-GALVANIZED MEMBERS OR PARTS (EXISTING
OR NEW) SHALL BE PAINTED WITH (2) COATS OF ZINC RICH PAINT (ZRC PREFERRED).
4. GUY ANCHOR GALVANIZATION SHALL EXTEND A MIN OF 6" INTO CONCRETE.
BOLTS:
1. ALL CONNECTIONS OF STRUCTURAL STEEL MEMBERS SHALL BE MADE USING SPECIFIED HIGH STRENGTH ASTM
A325 BOLTS WITH THREADS EXCLUDED IN SHEAR PLANE.
2. FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES.
3. ALL BOLTS WITHOUT DTI WASHERS SHALL BE INSTALLED SNUG FIT UNTIL THE SECTION IS FULLY COMPACTED, AND THEN TIGHTENED FURTHER BY AISC - "TURN OF THE NUT", TIGHTENING SHALL PROGRESS
SYSTEMATICALLY.
4. BOLT LENGTHS UP TO AND INCLUDING FOUR DIAMETERS SHALL BE TENSIONED 1/3 TURN BEYOND SNUG FIT.
BOLT LENGTHS OVER 4 DIAMETERS SHALL BE 1/2 TURN BEYOND SNUG FIT.
5. FOR SITES WITH DTI WASHERS, REFER TO MANUFACTURER’S RECOMMENDED CALIBRATION PROCEDURE.
HTTP://WWW.APPLIEDBOLTING.COM/PDF/SQUIRT_INSTALL.PDF
CHECK THE FIRST SET OF BOLTS WITH THE RECOMMENDED FEELER GAUGE TO VERIFY THE PROPER
AMOUNT OF “SQUIRT”.
FOR THE REMAINING BOLTS WITH DTI WASHERS, TIGHTEN UNTIL THE VOLUME AND APPEARANCE OF THE
SQUIRT MATCHES THE FIRST “CALIBRATION” SET. THE NUMBER OF SQUIRTS MUST BE AT LEAST THE NUMBER OF BUMPS MINUS ONE. (FOR INSTANCE A FIVE BUMP DTI SHOULD SQUIRT IN AT LEAST FOUR
PLACES).
PHOTOS OF THE FULLY ENGAGED SQUIRTER DTI WASHERS MUST BE TAKEN WITHIN 24 HOURS OF
INSTALLATION BY THE CONTRACTOR.
6. FOR SETS OF BOLT, TIGHTEN GROUP INCREMENTALLY. COMPRESS ALL UNTIL MEMBERS ARE IN FIRM CONTACT.
THEN COMPLETE FINAL BOLT TENSIONING.
SHOP WELDS:
1. ALL WELDING TO BE PERFORMED BY AWS CERTIFIED WELDERS AND CONDUCTED IN ACCORDANCE WITH AISC
AND AWS WELDING CODE - STEEL AWS D1.1/D1.1M:2006 SPECIFICATIONS AND RECOMMENDATIONS.
2. NO FIELD WELDING ALLOWED EXCEPT CAD WELD FOR GROUNDING.
TOLERANCES:
1. CONSTRUCTION OF TOWERS SHALL MEET ALL OF THE TOLERANCE REQUIREMENTS AS OUTLINED IN CHAPTER
6.1.2 OF THE TIA CODE.
GROUT:
1. ALL GROUT BENEATH BASE PLATES SHALL BE NON-SHRINK, "EMBECO","FIVE-STAR" OR EQUAL.
2. ALL GROUT SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 5,000 PSI. U.N.O.
STRUCTURAL ERECTION AND BRACING REQUIREMENTS:
1. THE STRUCTURAL DRAWINGS ILLUSTRATE THE COMPLETED STRUCTURE WITH ALL ELEMENTS IN THEIR FINAL
POSITIONS, PROPERLY SUPPORTED AND BRACED.
2. THE CONTRACTOR, IN THE PROPER SEQUENCE, SHALL PROVIDE TEMPORARY BRACING AS MAY BE REQUIRED
DURING CONSTRUCTION TO ACHIEVE THE FINAL COMPLETED STRUCTURE.
3. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE
BRACING ELEMENTS.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL TEMPORARY SUPPORTS, GUYING, ETC. NECESSARY TO PROVIDE A COMPLETE AND STABLE STRUCTURE AS SHOWN ON THESE DRAWINGS.
5. CONTRACTOR’S PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESS TO ANY EXISTING
OPERATIONAL AND SAFETY EQUIPMENT.
LIGHTING:
1. IF LIGHTING IS REQUIRED PER FAA AC70 ADVISORY CIRCULAR, ALL EQUIPMENT TO BE PROVIDED BY OTHERS
PROTECTIVE GROUNDING:
1. GROUNDING OF THE TOWER SHALL BE IN ACCORDANCE WITH SECTION 10 OF THE TIA-222-G CODE WITH THE
FOLLOWING EXCEPTIONS:
NO TESTING TO VERIFY FINAL RESISTANCE WILL BE COMPLETED UNLESS SPECIFICALLY REQUESTED BY
CLIENT AND NOTED IN THE DRAWINGS.
ALTERNATIVE GROUNDING METHODS FOR SITE SPECIFIC CONDITIONS DESIGNED IN ACCORDANCE WITH
MOTOROLA R56 “STANDARDS AND GUIDELINES FOR COMMUNICATION SITES” MAY BE APPROVED BY
THE ENGINEER OF RECORD AND PRESENTED IN THE DRAWINGS.
MAINTENANCE:
1. A CONTINUOUS INSPECTION OF THE STRUCTURE SHALL BE COMPLETED PER TIA RECOMMENDATIONS AS
OUTLINED IN CHAPTER 14 OF THE TIA CODE. ANY DEFECTS SHALL BE REPORTED TO ENSURE THE STRUCTURAL
INTEGRITY FOR THE LIFE OF THE STRUCTURE.
SPECIAL INSPECTIONS:
1. ALL SPECIAL INSPECTIONS TO BE COMPLETED BY THE OWNER PER IBC 2009 CHAPTER 17.
DTFAEN-16-C-00329
4 3 prohibited.
W C
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
S-80-6
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SS
L L
AP
D
C H
K
SPECIFICATIONS
0/
/1
D
AT
E
SHEET TITLE:
BY
D
ES
C
R
IP
TI
O
N
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
ELEV: 0'-0" (TOP OF BASEPLATE)
ELEV: 20'-0"
ELEV: 40'-0"
ELEV: 83'-0"
ELEV: 76'-5"
ELEV: 80'-0"
ELEV: -4'-0"
ELEV: 60'-0"
7,81
A
SUITE 350
(703) 226-8025
VIENNA, VA 22182
1934 OLD GALLOWS RD
SEE STRUCTURAL COMPONENTS, LLC STRUCTURAL ANALYSIS
(DATED 10/20/2016) FOR TOWER LOADING
DETAILS AND ANALYSIS CALCULATIONS.
NOTES:
ALL TOWER PARTS ARE PUNCHED OR MARKED WITH LAST 4 DIGITS OF1.
PART OR WELDMENT NUMBER.
DIAGONAL REFERENCE (INSIDE) AND (OUTSIDE) REFER TO INSIDE OR2.
OUTSIDE OF THE TOWER FACE. A=CP-02353-26, B=CP-02353-27,
C=CP-02353-16, D=CP-02353-17.
BOTTOM TOP
A -4' - 0" 0' - 0" CA-00522-04, F-80
BOTTOM TOP
1 0'-0" 20'-0" CA-00523-08, D-T8-1,
D-T8-2
2 20'-0" 40'-0" CA-00523-03, D-T3
3 40'-0" 60'-0" CA-00523-02, D-T2
4 60'-0" 80'-0" CA-00523-01, D-T1
5 76'-5" 80'-0"
CA-00524-01-1,
CA-00524-01-2,
D-P1, D-P2, D-P3
6 76'-5" 83'-0" CA-00525-01, D-M6-1,
D-M6-2
7 0'-0" 80'-0" CA-00527-05, D-L80
8 0'-0" 80'-0" CA-00528-05, D-DG
INSTALL TOWER SECTION 3, CA-00523-03
INSTALL TOWER SECTION 2, CA-00523-02
INSTALL TOWER SECTION 1, CA-00523-01
INSTALL TOWER PLATFORM, CA-00524-01
INSTALL LADDER ASSEMBLY, CA-00527-05
ITEM DESCRIPTION
ELEVATION
DWG. NO.
INSTALL TOWER FOUNDATION
EXPOSURE C
CLASSIFICATION
EXPOSURE CATEGORY
TOWER SPECIFICATIONS
MANUFACTURER STRUCTURAL COMPONENTS, LLC
HEIGHT / MODEL NUMBER 80FT. SELF-SUPPORT w/ PLATFORM, 6 ANTENNA MOUNTS
AUTHOR / FILE # / DATE WESLEY CULVER, P.E. / 160954 / 10-20-16
CURRENT STRUCTURAL ANALYSIS
COMPANY
ELEVATION
CODE
DESIGN SPECIFICATIONS
CLASS III
TIA-222-G
TOPOGRAPHIC CATEGORY CATEGORY 1
STRUCTURAL COMPONENTS, LLC
INSTALL TOWER SECTION 8, CA-00523-08
INSTALL DYNA-GLIDE ASSEMBLY, CA-00528-05
INSTALL SWING ARM ASSEMBLY, CA-00525-01
DESCRIPTION
WIND SPEED (BARE) 150 MPH 3-SECOND GUST
FOUNDATION INSTALLATION SCHEDULE
TOWER MODIFICATION SCHEDULE
DWG. NO.ITEM
A B
CP
‐0
‐2
(2 ) P
AN
EL
S
CP
‐0
(2
AN
EL
S
CP
‐0
‐0
CP
‐0
(3
AN
EL
S
CP
‐0
(3
AN
EL
S
CP
‐0
‐0
CP
‐0
‐2
(3 ) P
AN
EL
S
CP
‐0
‐2
(3 ) P
AN
EL
S
CP
‐0
‐2
CP
‐0
‐2
C D
CP
‐0
‐1
N /A
SE
CT
IO
N
LE
G
D
IA
G O N
AL
(O U
TS
ID
E)
D
IA
G O N
AL
(IN
SI
D E)
CP
‐0
‐0
CW
‐0
‐0
CP-02353-30
nXgen - DTFAEN - Anchor Rod Template Angle
QTY: 8
WEIGHT: 10.84 LBS EACH
6'-3 1 4 "
7" 7"
6'-8"
7"
7"
6'-8"
9'-5 1 8 "
TOP VIEW
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02353-30 nXgen - DTFAEN - Anchor Rod Template Angle 0 8 2 CP-02354-22 nXgen - DTFAEN - Anchor Rod Template Plate A 0 8 3 CP-02354-23 nXgen - DTFAEN - Anchor Rod Template Flat Bar 0 4
4 H02-0016-08 1" A563DH GALVANIZED NUT 0 80
5 HK1-0815-10 1/2" x 1-1/2" x 1" BOLT HW KIT 0 40 6 H15-2100-45 1.0" Dia X 4'-6" X 8TPI Anchor Rod - A193-B7 HDG 0 16
H15-2100-45 1.0" Dia X 4'-6" X 8TPI Anchor Rod - A193-B7 HDG
QTY: 16
WEIGHT: 12.06 LBS EACH
4'-6"
34 2 1 05
PARTS LIST
DTFAEN-16-C-00329
prohibited.
CA-00522-04
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
BY
SHEET TITLE:
D
ES
C R
IP
TI
O N
L L
AP
D
C H
K
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/
2/
D
AT
E
W C
SS
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
CA-00522-04
nXgen - DTFAEN - Anchor Rod Template Assembly
WEIGHT: 409.51 LBS EACH
CP-02354-22
nXgen - DTFAEN - Anchor Rod Template Plate A
QTY: 8
WEIGHT: 6.55 LBS EACH
CP-02354-23
nXgen - DTFAEN - Anchor Rod Template Flat Bar
QTY: 4
WEIGHT: 7.60 LBS EACH
8'-11 1 8 "
TOP VIEW
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02353-09 nXgen - DTFAEN - K-Brace Horizontal A 0 8 2 CP-02353-11 nXgen - DTFAEN - K-Brace Diagonal A 0 8 3 CP-02353-16 nXgen - DTFAEN - Diagonal A 0 4 4 CP-02353-17 nXgen - DTFAEN - Diagonal A - Coped 0 4 5 CP-02353-20 nXgen - DTFAEN - Horizontal A 0 2 6 CP-02353-21 nXgen - DTFAEN - Diagonal C 0 4 7 CP-02353-22 nXgen - DTFAEN - Diagonal C - Coped 0 4 8 CP-02353-28 nXgen - DTFAEN - Sub-Horizontal Angle 0 2 9 CP-02354-06 nXgen - DTFAEN - K-Brace Plate A 0 4 10 CP-02354-11 nXgen - DTFAEN - Splice Plate A 0 8 11 CP-02354-12 nXgen - DTFAEN - Bent Splice Plate A 0 4 12 CW-00847-01 nXgen - DTFAEN - 80' Tower Base Leg Weldment 0 4
13 H82-0010-04 RINGFILL - 5/8" BOLT - 1/2" THICK 0 8
14 HK1-1020-12 5/8" x 2" x 1-1/4" BOLT HW KIT 0 168 15 HK1-1022-12 5/8" x 2-1/4" x 1-1/4" BOLT HW KIT 0 8 16 HK1-1025-12 5/8" x 2-1/2" x 1-1/4" BOLT HW KIT 0 48
HORIZONTAL & DIAGONAL REFRENCE TABLE
PART # LENGTH (L) ANGLE SIZE
CP-02353-09 7' - 4-1/2" L3x3x3/16" CP-02353-11 7' - 7/16" L4x4x5/16" CP-02353-16 8' - 5" L2.5x2.5x3/16" CP-02353-17 8' - 5" L2.5x2.5x3/16" CP-02353-20 7' - 3-1/2"" L2.5x2.5x3/16" CP-02353-21 9' - 5-13/16" L2.5x2.5x3/16" CP-02353-22 9' - 5-13/16" L2.5x2.5x3/16" CP-02353-28 3' - 8-1/2" L2x2x1/4"
CA-00523-08
nXgen - DTFAEN - 80' Tower Base Section
WEIGHT: 3130.34 LBS EACH
CP-02354-11
nXgen - DTFAEN - Splice Plate A
QTY: 8
WEIGHT: 8.88 LBS EACH
DTFAEN-16-C-00329
5 4 3 prohibited.
D
ES
C R
IP
TI
O N
PARTS LIST
CA-00523-08
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
W C
SS
L L
AP
D
C H
K
SHEET TITLE:
BY
0/
/1
D
AT
E
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
LENGTH (L)
CW-00847-01
nXgen - DTFAEN - 80' Tower Base Leg Weldment
QTY: 4
WEIGHT: 416.97 LBS EACH
20'-1"
CP-02354-12
nXgen - DTFAEN - Bent Splice Plate A
QTY: 4
WEIGHT: 15.01 LBS EACH
7'-6" FACE WIDTH TYP
CP-02354-06
nXgen - DTFAEN - K-Brace Plate A
QTY: 4
WEIGHT: 8.26 LBS EACH
4 3
D
ES
C R
IP
TI
O N
2 1
SHEET TITLE:
DTFAEN-16-C-00329
PARTS LIST
0CA-00523-03
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
prohibited.
W C
SS
L
L
SHEET TITLE:
AP
D
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
C H
K
0/
2/
D
AT
E
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
TOP VIEW
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02353-06 nXgen - DTFAEN - Section 3 Tower Leg 0 4 2 CP-02353-20 nXgen - DTFAEN - Horizontal A 0 3 3 CP-02353-21 nXgen - DTFAEN - Diagonal C 0 12 4 CP-02353-22 nXgen - DTFAEN - Diagonal C - Coped 0 12 5 CP-02353-28 nXgen - DTFAEN - Sub-Horizontal Angle 0 3 6 CP-02354-14 nXgen - DTFAEN - Splice Plate B 0 8 7 CP-02354-15 nXgen - DTFAEN - Bent Splice Plate B 0 4
8 H82-0010-03 RINGFILL - 5/8" BOLT - 3/8" THICK 0 12
9 HK1-1020-12 5/8" x 2" x 1-1/4" BOLT HW KIT 0 115 10 HK1-1025-12 5/8" x 2-1/2" x 1-1/4" BOLT HW KIT 0 32
CP-02353-21
nXgen - DTFAEN - Diagonal C
QTY: 12
WEIGHT: 29.59 LBS EACH
9'-5 13 16 "
CP-02354-15
nXgen - DTFAEN - Bent Splice Plate B
QTY: 4
WEIGHT: 6.74 LBS EACH
CA-00523-03
nXgen - DTFAEN - Tower Section 3
WEIGHT: 2114.65 LBS EACH
CP-02353-20
nXgen - DTFAEN - Horizontal A
QTY: 3
WEIGHT: 22.51 LBS EACH
7'-3 1 2 "
7'-6" FACE WIDTH TYP CP-02354-14
nXgen - DTFAEN - Splice Plate B
QTY: 8
WEIGHT: 4.21 LBS EACH
CP-02353-06
nXgen - DTFAEN - Section 3 Tower Leg
QTY: 4
WEIGHT: 293.44 LBS EACH
CP-02353-28
nXgen - DTFAEN - Sub-Horizontal Angle
QTY: 3
WEIGHT: 10.94 LBS EACH
3'-8 1 2 "
CP-02353-22
nXgen - DTFAEN - Diagonal C - Coped
QTY: 12
WEIGHT: 29.28 LBS EACH
9'-5 13 16 "
4 3 prohibited.
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
D
ES
C R
IP
TI
O N
CA-00523-02
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
PARTS LIST
W C
L L
AP
D
C H
K
SHEET TITLE:
SS
0/ 2/
D
AT
E
BY
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
TOP VIEW
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02353-07 nXgen - DTFAEN - Section 2 Tower Leg 0 4 2 CP-02353-23 nXgen - DTFAEN - Diagonal D 0 12 3 CP-02353-24 nXgen - DTFAEN - Diagonal D - Coped 0 12 4 CP-02353-25 nXgen - DTFAEN - Horizontal B 0 3 5 CP-02353-28 nXgen - DTFAEN - Sub-Horizontal Angle 0 3 6 CP-02354-14 nXgen - DTFAEN - Splice Plate B 0 8 7 CP-02354-15 nXgen - DTFAEN - Bent Splice Plate B 0 4
8 H82-0010-03 RINGFILL - 5/8" BOLT - 3/8" THICK 0 12
9 HK1-1020-12 5/8" x 2" x 1-1/4" BOLT HW KIT 0 69 10 HK1-1025-12 5/8" x 2-1/2" x 1-1/4" BOLT HW KIT 0 32
CP-02353-25
nXgen - DTFAEN - Horizontal B
QTY: 3
WEIGHT: 22.55 LBS EACH
7'-3 1 2 "
CP-02353-28
nXgen - DTFAEN - Sub-Horizontal Angle
QTY: 3
WEIGHT: 10.94 LBS EACH
3'-8 1 2 "
7'-6" FACE WIDTH TYP
CA-00523-02
nXgen - DTFAEN - Tower Section 2
WEIGHT: 1693.16 LBS EACH
CP-02353-23
nXgen - DTFAEN - Diagonal D
QTY: 12
WEIGHT: 29.86 LBS EACH
9'-6 11 16 "
CP-02354-14
nXgen - DTFAEN - Splice Plate B
QTY: 8
WEIGHT: 4.21 LBS EACH
CP-02354-15
nXgen - DTFAEN - Bent Splice Plate B
QTY: 4
WEIGHT: 6.74 LBS EACH
CP-02353-24
nXgen - DTFAEN - Diagonal D - Coped
QTY: 12
WEIGHT: 29.55 LBS EACH
9'- 11 16 "
CP-02353-07
nXgen - DTFAEN - Section 2 Tower Leg
WEIGHT: 191.79 LBS EACH
7'-6" FACE WIDTH TYP
CP-02353-26
nXgen - DTFAEN - Diagonal E
QTY: 4
WEIGHT: 25.37 LBS EACH
8'-1 1 2 "
CP-02353-24
nXgen - DTFAEN - Diagonal D - Coped
QTY: 8
WEIGHT: 29.55 LBS EACH
9'- 11 16 "
CP-02353-23
nXgen - DTFAEN - Diagonal D
QTY: 8
WEIGHT: 29.86 LBS EACH
9'-6 11 16 "
CP-02353-25
nXgen - DTFAEN - Horizontal B
QTY: 2
WEIGHT: 22.55 LBS EACH
7'-3 1 2 "
DTFAEN-16-C-00329
SS
4 3 prohibited.
SHEET TITLE:
CA-00523-01
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
L L
AP
D
C H
K
PARTS LIST
W C
0/
2/
D
AT
E
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
D
ES
C R
IP
TI
O N
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
CP-02353-08
nXgen - DTFAEN - Section 1 Tower Leg
QTY: 4
WEIGHT: 114.43 LBS EACH
TOP VIEW
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02353-08 nXgen - DTFAEN - Section 1 Tower Leg 0 4 2 CP-02353-23 nXgen - DTFAEN - Diagonal D 0 8 3 CP-02353-24 nXgen - DTFAEN - Diagonal D - Coped 0 8 4 CP-02353-25 nXgen - DTFAEN - Horizontal B 0 2 5 CP-02353-26 nXgen - DTFAEN - Diagonal E 0 4 6 CP-02353-27 nXgen - DTFAEN - Diagonal E - Coped 0 4 7 CP-02353-28 nXgen - DTFAEN - Sub-Horizontal Angle 0 3
8 H82-0010-02 RINGFILL - 5/8" BOLT - 1/4" THICK 0 12
9 HK1-1017-12 5/8" x 1-3/4" x 1-1/4" BOLT HW KIT 0 44 10 HK1-1020-12 5/8" x 2" x 1-1/4" BOLT HW KIT 0 15
CA-00523-01
nXgen - DTFAEN - Tower Section 1
WEIGHT: 1241.55 LBS EACH
CP-02353-28
nXgen - DTFAEN - Sub-Horizontal Angle
QTY: 3
WEIGHT: 10.94 LBS EACH
3'-8 1 2 "
CP-02353-27
nXgen - DTFAEN - Diagonal E - Coped
QTY: 4
WEIGHT: 25.07 LBS EACH
8'-1 1 2 "
2'-6"
TOP VIEW
PLATFORM AREA = 56.25 FT^2
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02355-01 nXgen - DTFAEN - Platform Top Girt 0 9 2 CP-02355-02 nXgen - DTFAEN - Platform Top Handrail 1 4 3 CP-02355-03 nXgen - DTFAEN - Platform Intermediate Handrail 0 4 4 CP-02355-04 nXgen - DTFAEN - Platform Clip Angle A 0 6 5 CP-02355-05 nXgen - DTFAEN - Platform Clip Angle B 0 8 6 CP-02355-06 nXgen - DTFAEN - Door Catch Angle 0 1 7 CP-02355-10 nXgen - DTFAEN - Platform Toe Board 0 4 8 CP-02355-11 nXgen - DTFAEN - Platform Grating A 0 2 9 CP-02355-12 nXgen - DTFAEN - Platform Grating B 0 1 10 CP-02355-13 nXgen - DTFAEN - Platform Grating C 0 1 11 CW-00848-01 nXgen - DTFAEN - Platform Hinge Weldment 0 1 12 CW-00848-02 nXgen - DTFAEN - Grating Door Weldment 0 1 13 H01-0817-10 1/2" x 1-3/4" 1" A325 STRUCTURAL BOLT 0 3
14 H02-0008-13 1/2" A563DH GALVANIZED NUT 0 6
15 H99-0004-01 GALVANIZED GRATING CLIP - 1" BEARING BAR HEIGHT 0 24
16 HK1-0815-10 1/2" x 1-1/2" x 1" BOLT HW KIT 0 32 17 HK1-0817-10 1/2" x 1-3/4" x 1" A325 BOLT HW KIT 0 44 18 HK1-0820-10 1/2" x 2" x 1" BOLT HW KIT 0 10
ELEVATION VIEW
NOTE: TOWER SECTION 1 LEGS (CP-02353-08) BECOME VERTICAL POSTS OF PLATFORM.
BY
W C
S S
4 3 2
DTFAEN-16-C-00329
prohibited.
0/
/1
PARTS LIST
CA-00524-01-1
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
P
AR
TS
L
IS
T
U
PD
AT
E
D
ES
C R
IP
TI
O N
L L
L L
AP
D
C H
K
SS
0/
3/
D
AT
E
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
SHEET TITLE:
W C
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
. 7'-6"
7'-6"
2'-6"
42"
23"
CA-00524-01
nXgen - DTFAEN - Platform Assembly
WEIGHT: 1114.54 LBS EACH
S
5 4 3 2 1
PARTS LIST
DTFAEN-16-C-00329
prohibited.
P
AR
TS
L
IS
T
U
PD
AT
E
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
CA-00524-01-2
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
BY
SHEET TITLE:
L L
AP
D
C H
K
SS
0/
/1
0/
3/
D
AT
E
W C
D
ES
C R
IP
TI
O N
L L
W C
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
CP-02355-02
nXgen - DTFAEN - Platform Top Handrail
QTY: 4
WEIGHT: 36.69 LBS EACH
7'-6"
DRAWINGS NTSNOTE:
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
CP-02355-01
nXgen - DTFAEN - Platform Top Girt
QTY: 9
WEIGHT: 42.09 LBS EACH
7'-4 1 2 "
CP-02355-13
nXgen - DTFAEN - Platform Grating C
QTY: 1
WEIGHT: 75.74 LBS EACH
3'-10 1 2 "
CP-02355-04
nXgen - DTFAEN - Platform Clip Angle A
QTY: 6
WEIGHT: 1.36 LBS EACH
3 1 2 "
CP-02355-06
nXgen - DTFAEN - Door Catch Angle
QTY: 1
WEIGHT: 12.66 LBS EACH
2'-7"
CP-02355-10
nXgen - DTFAEN - Platform Toe Board
QTY: 4
WEIGHT: 18.82 LBS EACH
7'-4 1 2 "
CP-02355-11
nXgen - DTFAEN - Platform Grating A
QTY: 2
WEIGHT: 75.74 LBS EACH
7'-4 1 2 "
CW-00848-01
nXgen - DTFAEN - Platform Hinge Weldment
QTY: 1
WEIGHT: 13.53 LBS EACH
2'-7"
CP-02355-03
nXgen - DTFAEN - Platform Intermediate Handrail
QTY: 4
WEIGHT: 24.01 LBS EACH
7'-6"
CP-02355-12
nXgen - DTFAEN - Platform Grating B
QTY: 1
WEIGHT: 18.89 LBS EACH
1'-2"
CP-02355-05
nXgen - DTFAEN - Platform Clip Angle B
QTY: 8
WEIGHT: 0.78 LBS EACH
2"
CW-00848-02
nXgen - DTFAEN - Grating Door Weldment
QTY: 1
WEIGHT: 30.49 LBS EACH
2'-7 1 2 "
8' MIN PIPE
SEPARATION
CP-02356-09
nXgen - DTFAEN - 6 Antenna Tie Back Angle B
QTY: 2
WEIGHT: 19.07 LBS EACH
3'-10 5 8 "
CP-02356-07
nXgen - DTFAEN - NPS 2-1/2 Sch 40 Aluminium Pipe
QTY: 6
WEIGHT: 13.96 LBS EACH
7'-0"
S S
W C
4 3 2 1 P
AR
TS
L
IS
T U
PD
AT
E
DTFAEN-16-C-00329
prohibited.
0/
/1
CA-00525-01
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SS
L L
PARTS LIST
L L
AP
D
C H
K
D
ES
C R
IP
TI
O N
0/
/1
D
AT
E
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
SHEET TITLE:
W C
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
TOP VIEW
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02356-02 nXgen - DTFAEN - 6 Antenna Mount Plate A 0 4 2 CP-02356-03 nXgen - DTFAEN - 6 Antenna Mount Plate B 0 4 3 CP-02356-07 nXgen - DTFAEN - NPS 2-1/2 Sch 40 Aluminium Pipe 0 6 4 CP-02356-08 nXgen - DTFAEN - 6 Antenna Tie Back Angle A 1 4 5 CP-02356-09 nXgen - DTFAEN - 6 Antenna Tie Back Angle B 1 2 6 CP-02356-10 nXgen - DTFAEN - 6 Antenna Horizontal Angle A 1 8 7 CP-02356-11 nXgen - DTFAEN - 6 Antenna Horizontal Angle B 1 4 8 CP-02356-12 nXgen - DTFAEN - 6 Antenna Diagonal Angle A 0 8 9 CP-02356-13 nXgen - DTFAEN - 6 Antenna Diagonal Angle B 0 4
10 H82-0008-02 RINGFILL - 1/2" BOLT - 1/4" THICK 0 6
11 HK1-0815-10 1/2" x 1-1/2" x 1" BOLT HW KIT 0 84 12 HK1-0820-10 1/2" x 2" x 1" BOLT HW KIT 0 6 13 HK6-4030-05 1/2" x 3-1/16" x 5" x 2-1/2" U-BOLT HW KIT 0 12
CP-02356-02
nXgen - DTFAEN - 6 Antenna Mount Plate A
QTY: 4
WEIGHT: 6.84 LBS EACH
CP-02356-12
nXgen - DTFAEN - 6 Antenna Diagonal Angle A
QTY: 8
WEIGHT: 14.74 LBS EACH
4'-7 5 16 "
CA-00525-01
nXgen - DTFAEN - 6 Antenna Swing Arm Assembly
WEIGHT: 651.71 LBS EACH
CP-02356-08
nXgen - DTFAEN - 6 Antenna Tie Back Angle A
QTY: 4
WEIGHT: 18.07 LBS EACH
3'-8 3 16 "
CP-02356-13
nXgen - DTFAEN - 6 Antenna Diagonal Angle B
QTY: 4
WEIGHT: 11.90 LBS EACH
3'-8 11 16 "
CP-02356-10
nXgen - DTFAEN - 6 Antenna Horizontal Angle A
QTY: 8
WEIGHT: 20.68 LBS EACH
4'-3"
CP-02356-11
nXgen - DTFAEN - 6 Antenna Horizontal Angle B
QTY: 4
WEIGHT: 13.20 LBS EACH
2'-8 3 4 "
CP-02356-03
nXgen - DTFAEN - 6 Antenna Mount Plate B
WEIGHT: 3.06 LBS EACH
CP-02353-29
nXgen - DTFAEN - Ladder Stand Off Angle
QTY: 26
WEIGHT: 3.64 LBS EACH
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-02274-04 nXgen - CC - Ladder Splice Plate 0 12 2 CP-02353-29 nXgen - DTFAEN - Ladder Stand Off Angle 0 26 3 CP-02354-17 nXgen - DTFAEN - Ladder Grab Bar 0 2 4 CW-00848-04 nXgen - DTFAEN - 20' Ladder Weldment 0 4 5 HK1-0815-10 1/2" x 1-1/2" x 1" BOLT HW KIT 0 2 6 HK1-1017-12 5/8" x 1-3/4" x 1-1/4" BOLT HW KIT 0 26 7 HK1-1020-12 5/8" x 2" x 1-1/4" BOLT HW KIT 0 28 8 HK1-1222-13 3/4" x 2-1/4" x 1-3/8" BOLT HW KIT 0 24
45 3
0/
3/
2 1
D
ES
C R
IP
TI
O N
DTFAEN-16-C-00329
PARTS LIST
CA-00527-05
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
prohibited.
C H
K
REVISION:
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
SHEET TITLE:
L L
SHEET TITLE:
W C
SS
D
AT
E
AP
D
BY
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
CA-00527-05
nXgen - DTFAEN - 80' Tower Ladder Assembly
WEIGHT: 1040.96 LBS EACH
CP-02274-04
nXgen - CC - Ladder Splice Plate
QTY: 12
WEIGHT: 1.31 LBS EACH
CW-00848-04
nXgen - DTFAEN - 20' Ladder Weldment
QTY: 4
WEIGHT: 219.55 LBS EACH
DETAIL A
SCALE 1 : 32
CP-02354-17
nXgen - DTFAEN - Ladder Grab Bar
QTY: 2
WEIGHT: 4.68 LBS EACH
NOTE: DRAWINGS NTS
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
ITEM NO. PART # DESCRIPTION REV. QTY.
1 CP-01663-01 NXGEN - WBS AIRPORT - DYNA-GLIDE RAIL CONNECTOR (506329) 0 10
2 CP-01663-03 NXGEN - WBS AIRPORT - DYNA-GLIDE RUNG MOUNT (506273) 0 22
3 CP-01663-05 NXGEN - WBS AIRPORT - DYNA-GLIDE RAIL (506270) 0 11
4 CP-01663-07 NXGEN - WBS AIRPORT - DYNA-GLIDE BOTTOM END STOP (506275) 0 1
5 CP-01663-09 NXGEN - WBS AIRPORT - 1/2" x 2-1/2" CARRIAGE BOLT 0 44 6 CP-01663-10 NXGEN - WBS AIRPORT - 1/2" x 1-1/4" CARRIAGE BOLT 0 20
7 CP-01663-13 DYNA-GLIDE PIVOT DAVIT (506357) 0 1
8 H02-0008-13 1/2" A563DH GALVANIZED NUT 0 64
9 H03-0008-02 1/2" DIA. F436 HARDENED GALVANIZED WASHER 0 64
10 H04-0008-01 1/2" SPRING LOCK WASHER 0 64
DYNA-GLIDE NOTES:
1. REFERENCE DYNA-GLIDE SYSTEM INSTRUCTION MANUAL FOR ADDITIONAL PART DETAILS.
2. (2) DYNA-GLIDE FALL ARRESTERS (P/N 506277) SUPPLIED PER SITE LOCATION.
DTFAEN-16-C-00329
5 4 3 prohibited.
PARTS LIST
0CA-00528-05
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
SS
L
L
AP
D
C H
K
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/
/1
D
AT
E D
ES
C
R
IP
TI
O
N
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
CA-00528-05
nXgen - DTFAEN - 80' Tower Dyna-Glide Assembly
WEIGHT: 174.02 LBS EACH
CP-01663-05
DYNA-GLIDE RAIL (506270)
QTY: 11
WEIGHT: 13.03 LBS EACH
CP-01663-01
DYNA-GLIDE
RAIL CONNECTOR (506329)
QTY: 10
WEIGHT: 0.85 LBS EACH
DETAIL A
SCALE 1 : 12
CP-01663-03
DYNA-GLIDE
RUNG MOUNT (506273)
QTY: 22
WEIGHT: 0.64 LBS EACH
BY
3 2 1 0
DTFAEN-16-C-00329
prohibited.
SHEET TITLE:
D-T8-1
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
INSTALLATION DETAILS
D
ES
C R
IP
TI
O N
L L
AP
D
C H
K
SS
0/
/1
D
AT
E
W C
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
DETAIL A
HORIZONTAL INSTALLATION
TO AVOID OBSTRUCTING BOTTOM
TRIM ANCHOR RODS AS NECESSARY
TO LEG INSTALLATION.
TYPICAL LEG INSTALL DETAIL
NOTE: LEVEL LOWER 1" NUTS
ON ALL ANCHOR RODS PRIOR
CW-00847-01
INSTALL CW-00847-01 TO ANCHOR
RODS AS SHOWN USING:
(4) 1" NUTS BELOW BASEPLATE
(8) 1" NUTS ABOVE BASEPLATE
TYP PER LEG
CP-02353-09
DETAIL B
TYPICAL HORIZ & K-BRACE DETAIL
CP-02353-11
INSTALL CP-02353-11 AND
CP-02353-09 TO THE TOWER
LEG USING:
(2) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
CP-02353-11
DETAIL C
CP-02354-06
TYPICAL K-BRACE PLATE DETAIL
CP-02353-09
CP-02353-11
INSTALL (2) CP-02353-11 TO
CP-02354-06 AS SHOWN USING:
(2) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
INSTALL CP-02354-06 TO
CP-02353-09 AS SHOWN USING:
(2) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
(703) 226-8025
VIENNA, VA 22182
1934 OLD GALLOWS RD
SUITE 350
INSTALLATION DETAILS
B
C
A
TOWER SECTION 8 INSTALLATION
CP-02353-28
BE MOUNTED TO EITHER SIDE
MOUNTED. CP-02353-28 CAN
OF THE X-BRACE PANEL.
CP-02353-20
CP-02353-28
CP-02353-22
CP-02353-16
CP-02353-20
CP-02353-09
CP-02353-21
NOTE: CP-02353-20 &
CP-02353-28 HORIZONTALS
ARE TO BE INSTALLED ONLY
ON THE TOWER FACE TO
WHICH THE LADDER WILL BE
CP-02353-17
CONNECT HORIZONTALS AND
DIAGONALS TO THE LEG USING
(2) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
NOTE: CP-02353-22 IS COPED
TO BE USED ON THE INSIDE
OF THE TOWER FACE ONLY.
DETAIL D
TOWER SECTION 8 BRACING (CONT'D)
STITCH TOGETHER DIAGONALS
AS SHOWN USING:
(1) 5/8" x 2-1/4" BOLT W/HW
(1) H82-0010-03 RINGFILL
TYP PER LOCATION
VIENNA, VA 22182
INSTALLATION DETAILS
SUITE 350
1934 OLD GALLOWS RD
(703) 226-8025
NOTE: RINGFILLS ARE
NOT REQUIRED WHEN
SUB-HORIZ. IS INSTALLED
TO X-BRACE PANEL.
NOTE: CP-02353-17 IS COPED
TO BE USED ON THE INSIDE
OF THE TOWER FACE ONLY.
REVISION:
DTFAEN-16-C-00329
4 2 1 0
BY
D
AT
E
INSTALLATION DETAILS
D-T8-2
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
0/
/1
AP
D
SS
L L prohibited.
W C
SHEET TITLE:
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
C H
K
SHEET TITLE:
D
ES
C R
IP
TI
O N
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
BRACING SHOWN BELOW
TOWER SECTION 3 INSTALLATION
SECTION 3 MAY VARY.
NOTE:
D
E
AS SHOWN USING:
(1) H82-0010-03 RINGFILL
TYP PER LOCATION
SECTION 3 TYPICAL BRACING
DETAIL E
CP-02353-20
CP-02353-20
CP-02353-28
CP-02353-22
CONNECT HORIZONTALS AND
DIAGONALS TO THE LEG USING
OF THE TOWER FACE ONLY.
TO BE USED ON THE INSIDE
CP-02353-22 IS COPEDNOTE:
(1) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
MOUNTED. CP-02353-28 CAN
WHICH THE LADDER WILL BE
ON THE TOWER FACE TO
ARE TO BE INSTALLED ONLY
CP-02353-28 HORIZONTALS
OF THE X-BRACE PANEL.
BE MOUNTED TO EITHER SIDE
CP-02353-21
(2) 5/8" x 2" BOLT W/HW
NOTE: CP-02353-20 &
STITCH TOGETHER DIAGONALS CONNECT SUB-HORIZONTAL
TO THE LEG USING:
(1) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
SHEET TITLE:
DTFAEN-16-C-00329
5 4 3 prohibited.
BY
D
ES
C
R
IP
TI
O
N
D-T3
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
INSTALLATION DETAILS
L L
AP
D
C H
K
W C
0/
4/
D
AT
E
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
SS
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
1934 OLD GALLOWS RD
SUITE 350
INSTALLATION DETAILS
(703) 226-8025
VIENNA, VA 22182
NOTE: RINGFILLS ARE
NOT REQUIRED WHEN
SUB-HORIZ. IS INSTALLED
TO X-BRACE PANEL.
CP-02354-11
CP-02354-12
DETAIL D
SECTION 3 LOWER SPLICE DETAIL
CW-00847-02
CP-02353-06
SPLICE TOWER LEGS TOGETHER
AS SHOWN USING:
(12) 5/8" x 2-1/2" BOLT W/HW
(2) CP-02354-11
(1) CP-02354-12
TYP PER LOCATION
CP-02353-06
CP-02353-07
DETAIL F
SECTION 2 LOWER SPLICE DETAIL
CP-02354-15
SPLICE TOWER LEGS TOGETHER
AS SHOWN USING:
(8) 5/8" x 2-1/2" BOLT W/HW
(2) CP-02354-14
(1) CP-02354-15
TYP PER LOCATION
CP-02354-14
1934 OLD GALLOWS RD
SUITE 350
INSTALLATION DETAILS
(703) 226-8025
VIENNA, VA 22182
TO X-BRACE PANEL.
SUB-HORIZ. IS INSTALLED
NOT REQUIRED WHEN
RINGFILLS ARENOTE:
NOTE: CP-02353-25 &
CP-02353-28 HORIZONTALS
ARE TO BE INSTALLED ONLY
ON THE TOWER FACE TO
WHICH THE LADDER WILL BE
MOUNTED. CP-02353-28 CAN
BE MOUNTED TO EITHER SIDE
OF THE X-BRACE PANEL.
DTFAEN-16-C-00329
BY
4 3 prohibited.
INSTALLATION DETAILS
D-T2
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SS
L
L
AP
D
C H
K
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/ 4/
D
AT
E
W C
SHEET TITLE:
D
ES
C R
IP
TI
O N
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
TOWER SECTION 2 INSTALLATION
F
G
CONNECT SUB-HORIZONTAL
(1) 5/8" x 2" BOLT W/HW
SECTION 2 TYPICAL BRACING
DETAIL G
CP-02353-25
CP-02353-24 IS COPED
OF THE TOWER FACE ONLY.
TO BE USED ON THE INSIDE
CP-02353-25
CP-02353-24
NOTE:
TO THE LEG USING:
TYP PER LOCATION
CP-02353-28
CP-02353-23
CONNECT HORIZONTALS AND
DIAGONALS TO THE LEG USING
(1) 5/8" x 2" BOLT W/HW
TYP PER LOCATION
STITCH TOGETHER DIAGONALS
AS SHOWN USING:
(1) 5/8" x 2" BOLT W/HW
(1) H82-0010-03 RINGFILL
45 3
W C
2 1 prohibited.
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
D-T1
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
INSTALLATION DETAILS
DTFAEN-16-C-00329
D
AT
E D
ES
C
R
IP
TI
O
N
L L
SS
AP
D
C H
K
BY
0/
4/
REVISION:
SHEET TITLE:
SHEET TITLE:
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
TO X-BRACE PANEL.
SUB-HORIZ. IS INSTALLED
(703) 226-8025
INSTALLATION DETAILS
SUITE 350
NOT REQUIRED WHEN
RINGFILLS ARE
1934 OLD GALLOWS RD
NOTE:
VIENNA, VA 22182
NOTE: CP-02353-25 &
CP-02353-28 HORIZONTALS
ARE TO BE INSTALLED ONLY
ON THE TOWER FACE TO
WHICH THE LADDER WILL BE
MOUNTED. CP-02353-28 CAN
BE MOUNTED TO EITHER SIDE
OF THE X-BRACE PANEL.
TOWER SECTION 1 INSTALLATION
H
I
TYP PER LOCATION
CP-02353-08
CP-02353-07
CP-02354-14
DETAIL H
SECTION 1 LOWER SPLICE DETAIL
SPLICE TOWER LEGS TOGETHER
AS SHOWN USING:
(8) 5/8" x 2-1/2" BOLT W/HW
(2) CP-02354-14
(1) CP-02354-15
CP-02354-15
CP-02353-24
CP-02353-28
CP-02353-27
OF THE TOWER FACE ONLY.
TYP PER LOCATION
DIAGONALS TO THE LEG USING
CP-02353-24 IS COPED
TO BE USED ON THE INSIDE
(1) 5/8" x 2" BOLT W/HW
NOTE:
DETAIL I
CONNECT HORIZONTALS AND
TYP PER LOCATION
CP-02353-25
CP-02353-25
SECTION 1 TYPICAL BRACING
TYP PER LOCATION
CP-02353-23
(1) 5/8" x 2" BOLT W/HW
TO THE LEG USING:
CONNECT SUB-HORIZONTAL
STITCH TOGETHER DIAGONALS
AS SHOWN USING:
(1) 5/8" x 2" BOLT W/HW
(1) H82-0010-03 RINGFILL
CP-02353-26
0"
11"
3'-4 1 2 "
4'-9 3 4 "
DTFAEN-16-C-00329
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited.
INSTALLATION DETAILS
0D-P1
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
SS
L
L
AP
D
C H
K
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/ 5/
D
AT
E D
ES
C
R
IP
TI
O
N
012345 N O
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
INSTALLATION DETAILS
TOP GIRT/PLATFORM FRAME TOP VIEW
LADDER/CLIMBING FACE
CP-02355-01 X (9)
CP-02355-04 X (6)
TOWER LEG
CP-02353-08
NOTE: VERIFY EDGE OF ANGLE (0")
TO CENTER OF BOLT LOCATION
SHOWN DURING INSTALLATION.
TOWER TOP GIRT DETAIL
DETAIL J
TYP PER LOCATION
TO BACK AS SHOWN USING:
CP-02353-08
INSTALL (2) CP-02355-01 BACK
(2) 1/2" x 2" BOLT W/HW
CP-02355-01 CP-02355-01
INSTALL (1) CP-02355-01
AS SHOWN USING:
(2) 1/2" x 1-3/4" BOLT W/HW TYP PER LOCATION (4) 1/2" x 1-3/4" BOLT W/HW
TYP PER LOCATION
BRACING CLIP ANGLE DETAIL
DETAIL K
CP-02355-04
CP-02355-01
CP-02355-01
INSTALL CP-02355-04 TO CONNECT
BRACING AS SHOWN USING:
VERIFY BOLT LOCATIONS
PER NOTE ABOVE
TOP GIRT/PLATFORM FRAME ISO
SECTION 1 TOWER LEG
CP-02353-08
NOTE: TOWER SECTION 1 BRACING
MEMBERS HIDDEN FOR CLARITY.
J
K
TOWER CLIMBING FACE
TOP GIRT/PLATFORM FRAME TOP VIEW (CONT'D)
TOWER LEG
CP-02353-08
CP-02355-01
N
HANDRAIL AND TOEBOARD DETAIL
DETAIL L
(1) 1/2" x 1-1/2" BOLT W/HW
CP-02355-02
CP-02355-03
CP-02355-02
CP-02355-03
CP-02355-10
CP-02355-10
INSTALL TOP AND INTERMEDIATE
HANDRAIL TO TOWER LEG AS
SHOWN USING:
INSTALL TOEBOARD TO TOWER
LEG AS SHOWN USING:
(2) 1/2" x 1-1/2" BOLT W/HW
TOP GIRT/PLATFORM FRAME ISO (CONT'D)
NOTE: HANDRAILS AND TOEBOARDS
HIDDEN FOR CLARITY. INSTALL ON
ALL FOURS SIDES.
CP-02355-10
CP-02355-03
CP-02355-02
CP-02355-06
CW-00848-01
M
L
TOWER CLIMBING FACE
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
INSTALLATION DETAILS
DTFAEN-16-C-00329
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited.
INSTALLATION DETAILS
0D-P2
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
SS
L
L
AP
D
C H
K
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/ 5/
D
AT
E D
ES
C
R
IP
TI
O
N
012345 N O
CW-00848-01
TYPICAL CLIP ANGLE DETAIL
DETAIL M
CP-02355-05
1/2" x 1-1/2" BOLT
HW KIT
LADDER OPENING DETAIL
DETAIL N
CW-00848-01
CP-02355-06
CP-02355-05 X (4)
TOP GIRT/PLATFORM FRAME TOP VIEW (CONT'D)
CP-02355-11
CP-02355-13
CP-02355-11
CP-02355-12
A
DTFAEN-16-C-00329
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited.
INSTALLATION DETAILS
0D-P3
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
SS
L
L
AP
D
C H
K
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/ 5/
D
AT
E D
ES
C
R
IP
TI
O
N
012345 N O
PLATFORM DOOR HINGE DETAIL
CW-00848-02
INSTALL CW-00848-02 TO HINGES
OF CW-00848-01 AS SHOWN USING:
(1) 1/2" x 1-3/4" BOLT
(2) NUTS
TYP (3) LOCATIONS
TIGHTEN FIRST NUT UNTIL THREAD
BOTTOMS OUT. INSTALL JAM NUT
ONTO FIRST NUT. DO NOT INSTALL
FLAT WASHER OR LOCK WASHER.
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
INSTALLATION DETAILS
TOP GIRT/PLATFORM FRAME ISO (CONT'D)
CW-00848-02
A
TOWER CLIMBING FACE
L L
MOUNT DETAILS
4 3 2 1
DTFAEN-16-C-00329
prohibited.
0/
/1
SHEET TITLE:
D-M6-1
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
W C
SS
D
ES
C R
IP
TI
O N
L L
AP
D
C H
K
T
IE
-B
AC
K U
PD
AT
E
0/
/1
D
AT
E
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
BY
W C
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
FINAL MOUNT CONFIGURATION
8' MIN ANTENNA
PIPE SPACING
8' MIN ANTENNA
PIPE SPACING
6 ANTENNA SWING ARM DETAIL
O
3.
2.
SERVICE IS COMPLETE.
RETURN ANTENNA MOUNT TO FINAL CONFIGURATION AND TIGHTEN BOLTS AFTER
SWING ARM NOTES:
TO SERVICE ANTENNA, LOOSEN BOLT IN ARC-SLOT, TOP & BOTTOM. REMOVE1.
STIFF ARM ANGLE AND ROTATE ANTENNA ASSEMBLY TOWARDS PLATFORM.
TO SERVICE ANTENNA ADJACENT STIFF ARM MUST BE ROTATED OUT OF THE WAY.
P
CP-02356-07
CP-02356-08
1/2" x 3-1/16"
HW KIT TYP
1/2" x 1-1/2" BOLT CP-02356-10
DETAIL O
SWING ARM A BRACING DETAIL
CP-02356-10
HW KIT W/RINGFILL
1/2" x 2" BOLT
U-BOLT HW KIT TYP
CP-02356-12
VIENNA, VA 22182
(703) 226-8025
1934 OLD GALLOWS RD
SUITE 350
MOUNT DETAILS
DETAIL P
CP-02356-10
SWING ARM A HANDRAIL CONNECTION
CP-02356-02
CP-02356-10
1/2" x 1-1/2" BOLT
HW KIT TYP
(703) 226-8025
VIENNA, VA 22182
1934 OLD GALLOWS RD
SUITE 350
MOUNT DETAILS
SERVICE IS COMPLETE.
3.
R
RETURN ANTENNA MOUNT TO FINAL CONFIGURATION AND TIGHTEN BOLTS AFTER
6 ANTENNA SWING ARM DETAIL
2.
SWING ARM NOTES:
TO SERVICE ANTENNA, LOOSEN BOLT IN ARC-SLOT, TOP & BOTTOM. REMOVE1.
STIFF ARM ANGLE AND ROTATE ANTENNA ASSEMBLY TOWARDS PLATFORM.
TO SERVICE ANTENNA ADJACENT STIFF ARM MUST BE ROTATED OUT OF THE WAY.
Q
W C
0/
/1
S
S
4 3 2
DTFAEN-16-C-00329
prohibited.
BY
SS
D-M6-2
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
MOUNT DETAILS
L L
AP
D
C H
K
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
D
ES
C R
IP
TI
O N
0/
/1
D
AT
E
L L
T
IE
-B
AC
K U
PD
AT
E W
C
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
HW KIT W/RINGFILL
1/2" x 1-1/2" BOLT
SWING ARM B BRACING DETAIL
DETAIL R
CP-02356-07
HW KIT TYP
CP-02356-09
1/2" x 2" BOLT
CP-02356-11
CP-02356-11
CP-02356-13
1/2" x 3-1/16"
U-BOLT HW KIT TYP
36" ANTENNA PIPE
EXTENSIONS TYP
SWING ARM B HANDRAIL CONNECTION
CP-02356-11
CP-02356-03
DETAIL Q
1/2" x 1-1/2" BOLT
ES
C R
IP
TI
O N
LADDER DETAILS
4 3 2
DTFAEN-16-C-00329
prohibited.
0D-L80
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
BY
SHEET TITLE:
W C
L L
AP
D
C H
K
0/
/1
D
AT
E
SS
IN
ST
AL
LA
TI
O N
D R
AW
IN
G S
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
(703) 226-8025
VIENNA, VA 22182
1934 OLD GALLOWS RD
SUITE 350
LADDER DETAILS
LADDER NOTES:
INSTALL 20' LADDER SECTIONS AT TOP OF TOWER.1.
LADDER RUNGS ARE OFFSET TOWARD CLIMBING SPACE. LADDER SECTIONS SHOULD BE ORIENTED SUCH2.
THAT LADDER RUNGS ARE ALWAYS CLOSER TO THE CENTER OF THE TOWER.
LADDER SECTION ARE UNIVERSAL IN CLIMBING DIRECTION AND CAN BE INSTALLED IN EITHER3.
ORIENTATION.
LADDER ASSEMBLY CONNECTS TO EVERY HORIZONTAL INSTALLED ON THE CLIMBING FACE OF THE TOWER.4.
TYPICAL LADDER SECTION SPLICE
DETAIL Q
CP-02274-04 X (2)
3/4" x 2-1/4" BOLT
HW KIT TYP
5/8" x 1-3/4" BOLT
DETAIL R
TYPICAL LADDER STANDOFF CONNECTION
CP-02353-29 X (2)
HW KIT TYP
5/8" x 1-3/4" BOLT
HW KIT TYP
HW KIT
HW KIT
5/8" X 1-3/4" BOLT
CP-02353-29
1/2" X 1-1/2" BOLT
CP-02354-17
5/8" X 2" BOLT
HW KIT X (2)
LADDER CONNECTION TO
TOP HANDRAIL
Q
80' LADDER INSTALLATION VIEW
*ANTENNA MOUNTS HIDDEN FOR CLARITY
R
PLATFORM FLOOR
LADDER CONNECTION AT
CP-02355-05 X (2)
TYP
1/2" x 1-3/4" BOLT
HW KIT X (2)
TYP
1/2" x 2" BOLT
CP-01663-09
TYPICAL RUNG MOUNT
CP-01663-03
DETAIL T
INSTALL (2) RUNG MOUNTS PER
RAIL SECTION, CP-01663-05, AS
SHOWN USING:
(1) CP-01663-03
(2) CP-01663-09 W/HW
TYP PER LOCATION
DYNA-GLIDE DETAILS
DTFAEN-16-C-00329
BY
4 3 prohibited.
D-DG
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SS
D
ES
C R
IP
TI
O N
L L
AP
D
C H
K
W C
0/
5/
D
AT
E
SHEET TITLE:
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly
N O
TYPICAL DYNA-GLIDE INSTALLATION
DYNA-GLIDE DETAILS
1934 OLD GALLOWS RD
SUITE 350
(703) 226-8025
VIENNA, VA 22182
DYNA-GLIDE NOTES:
INSTALL DYNA-GLIDE SAFETY RAIL SYSTEM CENTERED ON THE LADDER FOLLOWING THE MSA DYNA-GLIDE1.
INSTRUCTION MANUAL.
INSTALL RAIL SYSTEM FULL HEIGHT OF LADDER. TRIM BOTTOM RAIL SECTION AS NECESSARY.2.
CP-01663-01
CP-01663-10
DETAIL S
TYPICAL RAIL SECTION SPLICE
CP-01663-05
CP-01663-05
SPLICE TOGETHER RAIL SECTIONS,
CP-01663-05, AS SHOWN USING:
(1) CP-01663-01
(2) CP-01663-10 W/HW
20'-0" TYP
20'-0" TYP
8'-1 1
4 " TYP5'-11 3
8 " TYP 5'-11 3
8 " TYP 3" MIN CLEAR
COVER TYP
9 11
16 " MAX C-C
BOTH DIRECTIONS
TYP
4'-0"
9" ANCHOR ROD
EXTENSION
3'-6"
3" MIN CLEAR
COVER TYP
GRADE
FOUNDATION ELEVATION VIEW
FOUNDATION ISO VIEW
APPROXIMATELY 59.3 CUBIC
YARDS OF 3,000 PSI CONCRETE
USE ANCHOR ROD TEMPLATE CA-00522-04
TO PROPERLY SPACE ANCHOR RODS.
2'-3"
19'-6"
MIN R2 1
4 " INNER
REBAR A
#6 REBAR
TOP & BOT BOTH DIRECTION
QTY: 100
REBAR SCHEDULE
1934 OLD GALLOWS RD
SUITE 350
VIENNA, VA 22182
(703) 226-8025
FOUNDATION DETAILS
FOUNDATION PLAN VIEW
FOUNDATION NOTES:
1. REFERENCE SHEET CA-00522-04 FOR EXACT ANCHOR ROD SPACING.
2. TEMPLATE BOLTS ARE EXACT FIT FOR SPACING. INSTALLATION WILL BE SNUG.
3. BOTTOM ANCHOR ROD TEMPLATE MAY REST ON LOWER REBAR CAGE.
4. REMOVE UPPER ANCHOR ROD TEMPLATE PLATES AND ANGLES AFTER
FOUNDATION INSTALLATION IS COMPLETE.
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited.
FOUNDATION
DETAILS
0F-80
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
SS
L
L
AP
D
C H
K
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/
/1
D
AT
E D
ES
C
R
IP
TI
O
N
012345 N O
The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited.
0F-80
STAMP:
REVISIONS:
SITE INFORMATION:
DESIGN TYPE:
REVISION:
SHEET TITLE:
SHEET TITLE:
W C
SS
L
L
AP
D
C H
K
BY
IN
ST
AL
LA
TI
O
N D
R
AW
IN
G
S
0/
/1
D
AT
E D
ES
C
R
IP
TI
O
N
012345 N O
| F-80 REV 0.PDF |
| F-80 |
| Drawing View1 |
| Drawing View3 |
| Drawing View4 |
| Drawing View5 |
File details come from the government source that posted it.