DrawingAmended-JAXG RTR-171108.pdf

PDF 5 MB Posted

Attached to
Replacement and Re-cabling of Communication Towers (Combined Projects) at Jacksonville, FL
Solicitation number
697DCK-18-R-00013
Issued by

About this file

DrawingAmended-JAXG RTR-171108 (pdf)

View the file

Other files

File Type Posted
PastPerformanceSurvey.pdf PDF
20-SOW-SPECS-JAXF RTR-86pgs.pdf PDF
GFM-List-Revised-171108.pdf PDF
Solicitation Amendment 0001.pdf PDF
Solicitation Amendment 0002.pdf PDF
Commstructures 40 ft tower JAXH and JAXG.pdf PDF
Nxgen 40' tower JAXG and JAXH.pdf PDF
WageDeterminaton-FL170246.pdf PDF
PastPerformanceSurvey.doc DOC document
SolicitationDocument-697DCK-18-R-00013.pdf PDF
10-SOW-SPECS-JAX RCAG-86pgs.pdf PDF
JAX-D-1507879-G001A.pdf PDF
DrawingAmended-JAXF RTR-171108.pdf PDF
JunctionBoxLocations-171108.jpg JPG image
QuestionsAndAnswers-Consolidated.pdf PDF
DrawingAmended-JAX RCAG-171108.pdf PDF
DrawingAmended-JAXH RTR-171108.pdf PDF
30-SOW-SPECS-JAXG RTR-Rev1-86pgs.pdf PDF
40-SOW-SPECS-JAXH RTR-Rev1-86pgs.pdf PDF
Nxgen 80 ft tower JAX RCAG.pdf PDF
DrawingAmended-JAXG RTR-171108.pdf PDF
WageDeterminaton-FL170246.pdf PDF
SolicitationDocument-697DCK-18-R-00013.pdf PDF
DrawingAmended-JAX RCAG-171108.pdf PDF
Commstructures 40 ft tower JAXH and JAXG.pdf PDF
10-SOW-SPECS-JAX RCAG-86pgs.pdf PDF
GFM-List-Revised-171108.pdf PDF
Nxgen 80 ft tower JAX RCAG.pdf PDF
JAX-D-1507879-G001A.pdf PDF
JunctionBoxLocations-171108.jpg JPG image
Nxgen 40' tower JAXG and JAXH.pdf PDF
PastPerformanceSurvey.pdf PDF
PastPerformanceSurvey.doc DOC document
DrawingAmended-JAXF RTR-171108.pdf PDF
DrawingAmended-JAXH RTR-171108.pdf PDF
QuestionsAndAnswers-Consolidated.pdf PDF
Solicitation Amendment 0001.pdf PDF
Solicitation Amendment 0002.pdf PDF
20-SOW-SPECS-JAXF RTR-86pgs.pdf PDF
40-SOW-SPECS-JAXH RTR-Rev1-86pgs.pdf PDF
30-SOW-SPECS-JAXG RTR-Rev1-86pgs.pdf PDF
WageDeterminaton-FL170246.pdf PDF
DrawingAmended-JAXF RTR-171108.pdf PDF
DrawingAmended-JAXH RTR-171108.pdf PDF
20-SOW-SPECS-JAXF RTR-86pgs.pdf PDF
JAX-D-1507879-G001A.pdf PDF
10-SOW-SPECS-JAX RCAG-86pgs.pdf PDF
Nxgen 80 ft tower JAX RCAG.pdf PDF
GFM-List-Revised-171108.pdf PDF
PastPerformanceSurvey.pdf PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

G

F

E

D

C

B

8 7 6 5 •

TOWER

") 1

V

\�/ --------v�-----------0 / v�·--O 2

ANTENNA

MOUNT

FREQ

118.00 M / 317. 70 M

119.85 M / 322.40 M

121.90 M I 348.6 M

124.40 M / 284.60 M

SPARE

SPARE

308.40 M / 120.75 M

:i.135.60 M / 119.50 M

266.80 M / 118.30 M

SPARE

SPARE

ANT TYPE TOWER

UHF/VHF 3

UHF/VHF 3

UHF/VHF 3

UHF/VHF 3

UHF/VHF 4

UHF/VHF 4

UHF/VHF 4

ANTENNA

MOUNT

2 1

FREQ ANT TYPE

118.00 S / 317.70 S UHF/VHF

H

119.85 S / 322.40 S UHF/VHF

121. 90 s I 348.6 S UHF/VHF -

124.40 S / 284.60 S UHF/VHF

SPARE

G

SPARE

308.40 S / 120.75 S UHF/VHF

:i.135.60 S / 119.50 S UHF/VHF

266.80 S / 118.30 S UHF/VHF

F

SPARE

SPARE

OJ G1 nl G2 nl G3

I/

� CLIMBING DIAMOND /

� CLIMBING DIAMOND /

1 �ENTRY _

..,_-,-:;---�< �ENTRY

...,.....,.... .. e--, --� '1

I/

I

CLIMBING DIAMOND

ENTRY

2 6 SPARE 4 6 SPARE

V

\, V I / / \ I .,,/' I

// \ I /\ I / \ I ,,,/' \ I _,,, \ I / \ I ,,.,,,.\ I /

\ I ,,,.,,,.

\ I / \ I ,,/'

\ I ,,., \ I

\ I .,," \ I ,,.,,.

\ I .,/' \ I

.,"' \ I / \ I / \ I ,,,.r

\ I / \ I _,,;

\ I ,,/' \ I

\ I / \ I / \ I ,, ,,. ------, \ I ,,. r ------ ,, \ I ,,. ----

' \ I

\ ,1 ,,. ,, ', \.1 .,,.::::----- ', �--'--�

1----�---�-,_,_,........, _ ____, HV AC .-----. ',,,

i i I I I I I I I I

I

', 0--" ----� ..

, LJJ-ti G 4-'

LOUVEF

I I

I I I I I I I I I I I I I I I I

HVAC

/ 1 '

�004

I

ANTENNA LAYOUT DIAGRAM

NOT TO SCALE

CONTRACTOR SHALL PENETRATE

WALL AND INST ALL 4" PVC THROUGH

PENETRATION, THEN GROUT AROUND

PVC TO PREVENT LEAKS /

NEW BOX LOCATION \

I

VERIFY WITH COTR

E

D

FIBER OPTIC

DEMARK \ I HVAC 1-----. �-CONTROL DEMARK PANEL 1 : --,-1-...,_.---;.+-++i,+,t-----'---'---,_

/v

NEW BOX LOCATION -

VERIFY WITH COTR �

CONTRACTOR SHALL PENETRATE

WALL AND INSTALL 4" PVC THROUGH

PENETRATION, THEN GROUT AROUND

PVC TO PREVENT LEAKS

5 • j

I j I I I I I I

I I I I I I I i i I I I I I I I I

I

RADIO RACKS

V

NEW CABLE TRAY

: (TYPICAL OF 2l I

I I I I I

HVAC

I' 2 ' FLOOR PLAN

'l::004 NOT TO SCALE

4 3

�-ABANDONED COAXIAL

- V BUILDING ENTRANCE BOX

I _.,,,.---120/240 SINGLE PHASE

- V

MAIN POWER PANEL

-AUTOMATED TRANSFER SWITCH

C

RF\/ APPROVED

DATE DESCRIPTION f\[DI IM

DATE AP\ID B

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION §

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA �

RTR

PROPOSED FREQUENCY LAYOUT

JACKSONVILLE JACKSONVILLE INTL AIRPORT

REVIEWED BY

I

SUBMITTED BY N'PROVED BY

� � fJ .,,C[J 1

FL

• � �- OZCl52 U\cL1,1� i------i-������=------ - --J::'.--.:::::..:;::::::.._::::::��-- - -- -··--

PROJECT ENGINEER MGR: ENGINEERING • CENTER A

'DESIGNED iSSU::.D BY t-----t--J-RA_W_N - --� J

B

ENGINEERING SERVICES

COMMUNICATIONS BB

'ChECKED

CA.-E , I 'CN

07 /24/20171"

CRt\WlNG- NC 1507879

REV

JAXG-D-1507879-[005

i z

� u.

!!l

A

JAX-D-1402046-G001
JAXG RTR AMENDMENT
JAXG RTR Drawings complete rev 2a
JAXG RTR Drawings complete rev 2
JAXG RTR Drawings complete rev 2
JAXG RTR Drawings complete rev 1
jaxg-d-1402046-c001
jaxg-d-1402046-c002
jaxg-d-1402046-c003
JAX-D-1402046-C004
JAXG RTR Drawings complete rev 2a
jaxg-d-1507879-s001
jaxg-d-1507879-s002
JAXG RTR Drawings complete rev 2
JAXG RTR Drawings complete rev 2
JAXG RTR Drawings complete rev 1
jaxg-d-1402046-e001
jaxg-d-1402046-e003
jaxg-d-1402046-e004

jaxg-d-1507879-e004

File details come from the government source that posted it.