GENERAL REPAIR REPORT-TW.pdf
PDF 7 MB Posted
- Solicitation number
- 6973GH-18-R-00153
About this file
GENERAL REPAIR REPORT-TW (pdf)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CONTRACTOR'S RELEASE FORM.doc | DOC document | |
| TOWER REPAIR REPORT-WT.pdf | ||
| SOW.pdf | ||
| EXPERIENCE INFO FORM.pdf | ||
| TOWER REPAIR REPORT-BM.pdf | ||
| TOWER REPAIR REPORT-BP.pdf | ||
| WD-AZ180032.pdf | ||
| GENERAL REPAIR REPORT-BP.pdf | ||
| 6973GH-18-R-00153.pdf | ||
| GENERAL REPAIR REPORT-BM.pdf | ||
| TOWER REPAIR REPORT-WT.pdf | ||
| GENERAL REPAIR REPORT-TW.pdf | ||
| WD-AZ180032.pdf | ||
| GENERAL REPAIR REPORT-BM.pdf | ||
| CONTRACTOR'S RELEASE FORM.doc | DOC document | |
| EXPERIENCE INFO FORM.pdf | ||
| SOW.pdf | ||
| TOWER REPAIR REPORT-BP.pdf | ||
| GENERAL REPAIR REPORT-BP.pdf | ||
| TOWER REPAIR REPORT-BM.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Structural Analysis and Condition Assessment for LMR Sites
Whitetank Mountain, Arizona (AZ2143)
STRUCTURAL AND CONDITION ASSESSMENT
REPORT
September 9, 2016
SENSITIVE BUT UNCLASSIFIED (SBU) GSA Order #: GS-P-00-16-LY-7055 PROPERTY OF THE UNITED STATES GOVERNMENT GSA Contract #: GS-07-P-15-UC-D-7000
COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS PDN: EP-GS-P-00-16-LY-7055
DOCUMENT TO UNAUTHORIZED RECIPIENTS HGA Commission Number 2111-064-00
IS PROHIBITED
Do not remove this notice Properly destroy or return documents when no longer needed
420 North 5th Street, Suite 100 Minneapolis, Minnesota 55401
Tower Engineering Professionals
326 Tryon Road Raleigh, North Carolina 27603
STRUCTURAL AND CONDITION ASSESSMENT REPORT
FOR
[WHITETANK MOUNTAIN] AZ2143
80’ SELF SUPPORTING TOWER
BUCKEYE, MARICOPA COUNTY, ARIZONA
TEP # 69922_85717
Revision 0
Respectfully Submitted By:
Prepared For:
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Graham
Date: September 9, 2016
Stephen Fiskum, FAIA Tower Engineering Professionals
HGA Architects and Engineers 326 Tryon Road
420 5th Street North, Suite 100 Raleigh, NC 27603
Minneapolis, MN 55401 (919) 661-6351
(612) 758-4502 StructuresReview@tepgroup.net
Subject: Executive Summary
Tower Designation: Site Number: AZ2143
Site Name: Whitetank Mountain
Engineering Firm Designation: TEP Project Number: 69922_85717
Site Data: N. Tower Road, Buckeye, Maricopa County, AZ 85326
Lat., Long.: 33.575406, -112.578769
(N 33° 34' 31.46'', W 112° 34' 43.57”)
80 Foot ± – Self Supporting Tower
Tower Engineering Professionals (TEP) is pleased to provide this executive summary for the Phase I Scope of Work, which included a Maintenance and Condition Assessment, Capital Expenditure Table, Steel and Appurtenance
Mapping, and Structural Analysis for the above referenced site.
Maintenance and Condition Assessment
Overall Tower Condition (Excellent/Good/Average/Fair/Poor): Average*
Tower Type: 80-ft self supporting tower
Tower Age: Approximately 20-30 years**
Number of Guy Wires: N/A
Tower Access Road Condition: Poor, extremely rocky terrain, all-wheel drive vehicles with high ground clearance necessary
A periodic inspection for the above referenced site was performed by Kyle C. Edwards, P.E., C.W.I. and Andrew E.
Propst of TEP during the July 13, 2016 site visit. The inspection was in accordance with the ANSI/TIA-222-G-2005, Annex J: Maintenance and Condition Assessment (Normative). TEP observed the following checklist items requiring some measure of possible or required corrective action: 1) Structure Condition, 2) Finish, 3) Grounding, 4) Antennas and Lines, 5) Concrete Foundations, and 6) Non-TIA Related Items. Refer to the Maintenance and Condition
Assessment Report for specific details.
*TEP defines the tower conditions as follows:
Excellent - The tower has sufficient capacity to carry the existing loads. No modifications are required at this time. In addition, the tower has no maintenance issues of note and doesn’t require maintenance repairs at this time.
Good - The tower has sufficient capacity to carry the existing loads. No modifications are required at this time. However, the tower has some maintenance issues of note that require attention.
Average - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the
ANSI/TIA-222-G standard for the existing loading. In addition, the tower may have minor maintenance issues of note that require attention.
Fair - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the
ANSI/TIA-222-G standard for the existing loading. In addition, the tower has maintenance issues of note that require attention. Based on the itemized estimate in our Capital Expenditure Table, modifying the existing tower may be the most cost effective solution.
Poor - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the
ANSI/TIA-222-G standard for the existing loading. In addition, the tower has maintenance issues of note that require attention. Based on the itemized estimate in our Capital Expenditure Table and/or the condition of the tower, a full tower replacement may be the best solution.
**Tower Age was estimated based on tower identification tags, tower manufacturer information, tower research, type and condition of tower components, and/or historical site images
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP Project Number 69922_85717 September 9, 2016
AZ2143 - Whitetank Mountain
326 Tryon Road, Raleigh, NC 27603 (o) 919-661-6351 (f) 919-661-6350 www.tepgroup.net
Condition Assessment of Non-Tower Assets
During the site visit, TEP conducted a visual inspection of all Non-Tower Owned Assets. TEP did not find any non-tower assets that require urgent corrective repairs. However, TEP recommends regular inspection and maintenance by licensed professionals based on manufacturer specifications. Refer to Section L of the Maintenance and Condition
Assessment Report for any applicable additional information.
Asset Type Coordinates Condition Notes
Estimated
Remaining
Life
Shelter CMU Brick 33.575422, -112.578833 Good No major issues observed 10+ years
Roof Metal 33.575422, -112.578833 Good No major issues observed 10+ years
Shelter
Access
Single
Door
33.575422, -112.578833 Good
Located on northwest side of shelter, no major issues visible 10+ years
Power
Supply
Power
Meter
33.575422, -112.578833 Good Appears to be working properly 10+ years
Power
Supply Generator
33.575442, -112.578933 Good
Reli-On fuel cell generator, no major issues observed 10+ years
A/C Unit
(2)
Through
Wall
33.575422, -112.578833 Good
Mitsubishi and LG manufacturer tags, both appear to be working properly 10+ years
Cellular
Receivers
33.575422, -112.578833 Good
Shelter houses various units associated with communication equipment, no major issues of note
10+ years
Capital Expenditure Table
A cost estimate of $24,950 was provided to cover repairs and additional inspections as recommended in the
Maintenance and Condition Assessment Report and the Structural Analysis Report. The recommended repair schedule ranges from 6 months to 5 years. Also note that this estimate does not include any foundation reinforcements that may be required. TEP cannot say with certainty that modifying the existing tower would be more cost effective than a replacement without completing a Structural Modification Design Analysis. Refer to the
Capital Expenditure Table for details. For itemized repairs, refer to the Capital Expenditure Table for details. TEP estimated a ROM cost for full tower replacement would range from approximately $160,000 for a 100-ft self supporting tower to $250,000 for a 200-ft self supporting tower. These estimates do not include pricing for site specific costs related to zoning, permitting, environmental studies, etc.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Steel and Appurtenance Mapping
The original design criteria were unavailable for review. A Steel and Appurtenance Mapping was performed in order to obtain the necessary tower and appurtenance loading information needed to conduct the Structural Analysis for this site. The antennas recorded during our Steel and Appurtenance Mapping are depicted in the table below. TEP denoted the owner of the equipment under the “Owner/Tenant” column based on information available on site.
Refer to the Steel and Appurtenance Mapping Report for additional detail.
Elevation
(ft) Qty Antenna Model
Mount
Type
Owner/
Tenant
88.0 1 Andrew DB224-A Sidearm CBP
82.8 1 RFI BA40-41-DIN Sidearm CBP
81.0 1 1”Ø x 8’ Omni Sidearm PHX Fire
78.5 1 2.5”Ø x 10’ Omni Sidearm PHX Fire & Water
62.0 1 Empty Standoff Mount CBP
60.3 1 8’ Ø Grid Dish Pipe CBP
54.8 1 RFI BA40-41-DIN Sidearm CBP
50.0 1 Andrew DB224 Sidearm PHX Fire
37.0 1 Andrew DB224 Sidearm PHX Fire
35.0 1 8’ Ø Grid Dish Pipe CBP
32.3 1 3”Ø x 7’ Omni Sidearm PHX Fire & Water
31.0 1 Scala 94150-003 Pipe CBP
20.3 1 Radiation Systems P-22A72GF Pipe CBP
20.0 1 Radiation Systems P-22A96GF Pipe CBP
10.5 1 Andrew UHX10-59-P6A Pipe City of Phoenix
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Structural Analysis
The Structural Analysis report outlines overstresses in the tower diagonal bracing from 0’ to 39’ elevations. TEP believes that the majority of the overstresses can be attributed to the more stringent loading and analysis criteria as required by the latest ANSI/TIA-222-G-2-2009 Standard, as compared to previous versions of the TIA Standard for which the tower was originally designed. Based on our analysis we have determined the tower stress level for each controlling component, under the following load case, to be:
LC1: Existing Equipment Insufficient Capacity Note: See Table 1 for the existing loading
Thank you for the opportunity to provide this service for you. If you have any questions or comments, please contact our office.
Component % Capacity
Leg (T3) 71.2
Diagonal (T4) 160.4
Horizontal (T4) 38.9
Top Girt (T5) 40.8
Bolt Checks 38.7
Anchor Rods 18.5
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
MASTER TABLE OF CONTENTS
���� MAINTENANCE AND CONDITION ASSESSMENT
���� CAPITAL EXPENDITURE TABLE
���� ANNEX A: STEEL AND APPURTENANCE MAPPING
���� ANNEX B: STRUCTURAL ANALYSIS
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
MAINTENANCE AND CONDITION ASSESSMENT
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Date: September 9, 2016
HGA Architects and Engineers 326 Tryon Road
420 5th Street North, Suite 100 Raleigh, NC 27603
Minneapolis, MN 55401 (919) 661-6351
(612) 758-4502 StructuresReview@tepgroup.net
Subject: Maintenance and Condition Assessment Report
Tower Designation: Site Number: AZ2143
Site Name: Whitetank Mountain
Engineering Firm Designation: TEP Project Number: 69922_85717
Site Data: N. Tower Road, Buckeye, Maricopa County, AZ 85326
Lat., Long.: 33.575406, -112.578769
(N 33° 34' 31.46”, W 112° 34' 43.57”)
80 Foot ± – Self Supporting Tower
Dear Mr. Fiskum, Tower Engineering Professionals (TEP) completed a periodic inspection for the above referenced site. The onsite investigation was performed by Kyle C. Edwards, P.E., C.W.I. and Andrew E. Propst of TEP during the July 13, 2016 site visit. The inspection was in accordance with the ANSI/TIA-222-G-2005, Annex J: Maintenance and Condition Assessment
(Normative), including all addendums (addendums TIA-222-G-1 2007 and TIA 222-G-2 2009); the checklist can be found on pages 3 thru 8 of this report.
Observations and recommendations are listed herein. The inspection included observation of the tower components and CBP owned assets. For the purpose of this inspection, the tower legs were named by letter according to the magnetic azimuth defined by a line from the center of tower to the leg. “A” leg is the leg closest to magnetic north, followed clockwise by “B” and “C.”
Thank you for the opportunity to provide this service for you. If you have any questions or comments, please contact our office.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Self Supporting Tower Maintenance and Condition Assessment Report September 9, 2016
TEP Project Number 69922_85717 AZ2143 - Whitetank Mountain
TABLE OF CONTENTS
1) ANSI/TIA-222-G-MAINTENANCE AND CONDITION ASSESSMENT
2) SUMMARY
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANSI/TIA-222-G MAINTENANCE AND CONDITION ASSESSMENT
A. STRUCTURE CONDITION
A.1. Damaged members (legs and bracing)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
A.2. Loose members
Okay Possible Improvement Needs Repair Not Applicable
Notes:
A.3. Missing members
Okay Possible Improvement Needs Repair Not Applicable
Notes:
A.4. Climbing facilities, platforms, catwalks – all secure
Okay Possible Improvement Needs Repair Not Applicable
Notes: Missing nut locking device on ladder hardware. Safety climb cable cap is missing. See summary for details.
A.5. Loose and/or missing bolts and/or nut locking devices
Okay Possible Improvement Needs Repair Not Applicable
Notes: Missing leg bolt, loose secondary horizontal bolts, and skewed knife plates observed. See summary for details.
A.6. Visible cracks in welded connections
Notes:
B. FINISH
B.1. Paint and/or galvanizing condition
Notes:
B.2. Rust and/or corrosion condition including mounts and accessories
Okay Possible Improvement Needs Repair Not Applicable
Notes: Corroded mount hardware and surface corrosion observed on antenna mounts. See summary for details.
B.3. FAA or ICAO color marking conditions
Okay Possible Improvement Needs Repair Not Applicable
Notes:
B.4. Water collection in members (to be remedied, e.g., unplug drain holes, etc.)
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
C. LIGHTING
C.1. Conduit, junction boxes, and fasteners (weather tight and secure)
Notes:
C.2. Drains and vents openings (unobstructed)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.3. Wiring Condition
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.4. Light lenses
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.5. Bulb condition
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.6.a. Controllers functioning (Flasher)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.6.b. Controllers functioning (Photo control)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.6.c. Controllers functioning (Alarms)
D. GROUNDING
D.1. Connections
Notes: Insufficient weatherproofing on ground wire. See summary for details.
D.2. Corrosion
Okay Possible Improvement Needs Repair Not Applicable
Notes:
D.3. Lightning protection (secured to structure)
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E. ANTENNAS AND LINES
E.1. Antenna condition
Notes: Antenna located on C-leg at 32.3-ft is missing rain cap. See summary for details.
E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Loose antenna mounts and unused mounts were observed on the tower. See summary for details.
E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Coax is damaged and has insufficient weatherproofing. See summary for details.
E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
E.5. Secured to structure
F. OTHER APPURTENANCES (WALKWAYS, PLATFORMS, SENSORS, FLOODLIGHTS, ETC.)
F.1. Condition
Notes:
F.2. Secured to structure
G. INSULATOR CONDITION
G.1. Cracking and chipping
Notes:
G.2. Cleanliness of insulators
Okay Possible Improvement Needs Repair Not Applicable
Notes:
G.3. Spark gaps set properly
Okay Possible Improvement Needs Repair Not Applicable
Notes:
G.4. Isolation transformer condition
Okay Possible Improvement Needs Repair Not Applicable
Notes:
G.5. Bolts and connection secure
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
H. GUYS
H.1. Strand condition (corrosion, breaks, nicks, kinks, etc.)
Notes:
H.2.a. Guy Hardware Conditions (Turnbuckles or equivalent (secure and safety properly applied)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.b. Guy Hardware Conditions (Cable thimbles properly in place (if required))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.c. Guy Hardware Conditions (Service sleeves properly in place (if required))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.i. Guy Hardware Conditions (Cable connectors (end fittings) (Cable clamps applied properly and bolts tight))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.ii. Guy Hardware Conditions (Cable connectors (end fittings) (Wire serving properly applied))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.iii. Guy Hardware Conditions (Cable connectors (end fittings) (No signs of slippage or damaged strands))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.iv. Guy Hardware Conditions (Cable connectors (Preformed wraps – properly applied, fully wrapped, & sleeve in place))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.v. Guy Hardware Conditions (Cable connectors (end fittings) (Poured sockets secure and showing no separation))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.vi. Guy Hardware Conditions (Cable connectors (Shackles, bolts, pins, and cotter pins secure and in good condition))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.3. Guy tensions
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.4. Measure guy tensions
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.5. Record temperature, wind speed and wind direction
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
I. CONCRETE FOUNDATIONS
I.1.a. Ground condition (Settlement, movement or earth cracks)
Notes:
I.1.b. Ground condition (Erosion)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.1.c. Ground condition (Site condition (standing water, drainage, trees, etc.))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.2.a. Anchorage condition (Nuts and/or nut locking device (tightened))
Okay Possible Improvement Needs Repair Not Applicable
Notes: Half sized jam nut installed on top of anchor bolts. See summary for details.
I.2.b. Anchorage condition (Grout condition)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.2.c. Anchorage condition (Anchorages and/or anchor rod condition)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.a. Concrete condition (Cracking, spalling, or splitting)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.b. Concrete condition (Chipped or broken concrete)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.c. Concrete condition (Honeycombing)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.d. Concrete condition (Low spots to collect moisture)
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
J. GUYED MAST ANCHORS
J.1. Settlement, movement or earth cracks
Notes:
J.2. Backfill heaped over concrete for water shedding
Okay Possible Improvement Needs Repair Not Applicable
Notes:
J.3. Anchor rod condition below earth (Maintain required structural capacity of anchor during exploration.)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
J.4. Corrosion control measures (galvanizing, coating, concrete encasement, cathodic protection systems, etc.)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
J.5. Anchor heads clear of earth
K. TOWER ALIGNMENT
K.1. Tower Plumb and Twist
Notes: Tower twist and plumb was not measured as a part of this scope of work.
L. NON-TIA RELATED ITEMS
L.1. Equipment Shelter
Notes:
L.2. Security
Okay Possible Improvement Needs Repair Not Applicable
Notes: Perimeter fencing was not installed around the compound or guy anchor foundations. See summary for details.
L.3. Other Equipment
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
SUMMARY
Photograph Observations and Recommendations
A.4. Climbing facilities, platforms, catwalks (all secure)
Observation:
Missing nut locking device on ladder hardware at 59-ft.
Safety climb cable cap is missing.
Recommendation:
Install a nut locking device. If necessary, re-install a longer bolt to accommodate the use of a nut locking device. Tighten all nuts per the AISC "turn of the nut" method.
Replace safety climb cable cap.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
A.5. Loose and/or missing bolts and/or nut locking devices
Missing 5/8” dia. leg bolt observed to be replaced with a smaller bolt at 20-ft on the B-leg.
Loose A325 secondary horizontal bolt(s) observed on all faces from 20-ft to 60-ft.
Replace with a new A325N 5/8"dia. leg bolt. Tighten all nuts per the AISC "turn of the nut" method.
Tighten both U-bolt nuts per the AISC "turn of the nut" method.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
A.5. Loose and/or missing bolts and/or nut locking devices
Skewed knife plate gap observed on secondary horizontals typical throughout the tower height.
No action required. Based on a structural analysis, it has been determined that skewed knife plate gaps are not influential to structural capacity.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
B.2. Rust and/or corrosion condition including mounts and accessories
Corroded mount hardware observed on the antenna mount at 20-ft on the C-leg.
Surface corrosion observed on antenna mount at 73.5-ft on the A-leg.
Replace all corroded hardware per the mount manufacturer specifications. Install nut locking devices on all bolts. Tighten all nuts per the AISC "turn of the nut" method.
Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
D.1. Connections
Ground wiring has insufficient weatherproofing.
Repair ground wire weatherproofing to prevent water intrusion.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E.1. Antenna condition
Antenna located on C-leg at 32.3-ft is missing rain cap.
Repair or replace antenna.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)
Antenna mounts located on B-leg at 20-ft and on C-leg at
32.3-ft are loose.
Unused antenna mount on B-leg at 62-ft
Install nut locking devices. Tighten all nuts per AISC “turn of the nut” method
Removing the unused antenna mount will improve the overall structural capacity of the tower.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)
FH 7/8 coax from 7-ft to 60.3-ft is damaged at 20-ft.
FH 1/2 coax from has insufficient weatherproofing at 77-ft.
Repair coax.
Repair coax weatherproofing to prevent water intrusion.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
I.2.a. Anchorage condition (Nuts and/or nut locking device
(tightened))
Half sized jam nut installed on top of (1) anchor bolt at each leg.
Place the half sized nut on the bolt first. Tighten the nut to
50% of the overall tightening torque. Place the structural nut on the bolt. Hold the half sized nut to prevent rotation while the structural nut is tightened to the full torque value.
Torque all structural nuts per the requirements of the AISC
Steel Construction Manual.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
L.2. Security
Perimeter fencing was not installed around the compound or guy anchor foundations.
Install fencing around the compound and guy anchor foundations to ensure security of assets and provide protection to anchor foundations.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
CAPITAL EXPENDITURE TABLE
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANSI/TIA-222-G: CAPITAL EXPENDITURE TABLE
Job Name: AZ2143 - Whitetank Mountain
TEP Number: 69922_85717
A. STRUCTURAL CONDITION
Issue: Repair/Modification: Repair Schedule:
A.1. Damaged members (legs and bracing)
a. The following members were overstressed in the structural analysis:
i. Order Structural Design Drawings for modifications to failing/damaged members.
0-6 months $9,500
● Tower Diagonals from 0'-39'
Sub Total: $9,500
A.4. Climbing facilities, platforms, catwalks – all secure
a. Missing nut locking device on the ladder hardware at 59-ft.
b. Safety climb cable cap is missing.
i. Install a nut locking device. If necessary, re-install a longer bolt to accommodate the use of a nut locking device. Tighten all nuts per the AISC "turn of the nut" method.
ii. Replace safety climb cable cap.
0-6 months $50
Sub Total: $50
A.5. Loose and/or missing bolts and/or nut locking devices
a. Missing 5/8” dia. leg bolt observed to be replaced with a smaller bolt at 20-ft on the B-leg.
b. Loose A325 secondary horizontal bolt(s) observed on all faces from 20-ft to 60-ft.
c. Skewed knife plate gap observed on secondary horizontals typical throughout the tower height.
i. Replace with a new A325N 5/8"dia. leg bolt.
Tighten all nuts per the AISC "turn of the nut" method.
ii. Tighten both U-bolt nuts per the AISC "turn of the nut" method.
iii. No action required. Based on a structural analysis, it has been determined that skewed knife plate gaps are not influential to structural capacity.
0-6 months $150
Sub Total: $150
Total: $9,700
B. FINISH
Issue: Repair/Modification: Repair Schedule:
B.2. Rust and/or corrosion condition including mounts and accessories
a. Corroded mount hardware observed on the antenna mount at
20-ft on the C-leg.
b. Surface corrosion observed on antenna mount at
73.5-ft on the A-leg.
i. Replace all corroded hardware per the mount manufacturer specifications. Install nut locking devices on all bolts. Tighten all nuts per the AISC
"turn of the nut" method.
ii. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.
0-1 year $400
Sub Total: $400
Total: $400
C. LIGHTING
NO DEFICIENCIES WERE IDENTIFIED
D. GROUNDING
Issue: Repair/Modification: Repair Schedule:
D.1. Connections
a. Ground wiring has insufficient weatherproofing. i. Repair ground wire weatherproofing to prevent water intrusion.
0-1 year $150
Sub Total: $150
Total: $150
*Items that don't require attention were omitted from this list of itemized modification costs. For a full itemized list of everything that was assessed during our site visit please reference the Maintenance and Condition Assessment.
Fee:
Modification Fee:
Fee:
ii. Complete repairs as specified in Structural Design
Drawings.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E. ANTENNAS AND LINES
Issue: Repair/Modification: Repair Schedule:
E.1. Antenna condition
a. Antenna located on C-leg at 32.3-ft is missing rain cap. i. Repair or replace antenna. 0-5 years $350
Sub Total: $350
E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)
a. Antenna mounts located on B-leg at 20-ft and on C-leg at 32.3-ft are loose.
b. Unused antenna mount on B-leg at 62-ft
i. Install nut locking devices. Tighten all nuts per AISC
“turn of the nut” method
ii. Removing the unused antenna mount will improve the overall structural capacity of the tower.
0-1 year $350
Sub Total: $350
E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)
a. FH 7/8 coax from 7-ft to 60.3-ft is damaged at 20-ft.
b. FH 1/2 coax from has insufficient weatherproofing at 77-ft.
i. Repair coax.
Ii. Repair coax weatherproofing to prevent water intrusion.
0-1 year $250
Sub Total: $250
Total: $950
F. OTHER APPURTENANCES (WALKWAYS, PLATFORMS, SENSORS, FLOODLIGHTS, ETC.)
NO DEFICIENCIES WERE IDENTIFIED
G. INSULATOR CONDITION
NO DEFICIENCIES WERE IDENTIFIED
H. GUYS
NO DEFICIENCIES WERE IDENTIFIED
I. CONCRETE FOUNDATIONS
Issue: Repair/Modification: Repair Schedule:
I.2.a. Anchorage condition (Nuts and/or nut locking device
(tightened))
a. Half sized jam nut installed on top of (1) anchor bolt at each leg.
i. Place the half sized nut on the bolt first. Tighten the nut to 50% of the overall tightening torque. Place the structural nut on the bolt. Hold the half sized nut to prevent rotation while the structural nut is tightened to the full torque value. Torque all structural nuts per the requirements of the AISC Steel
Construction Manual.
0-1 year $250
Sub Total: $250
Total: $250
J. GUYED MAST ANCHORS
NO DEFICIENCIES WERE IDENTIFIED
K. TOWER ALIGNMENT
NO DEFICIENCIES WERE IDENTIFIED
Fee:
Fee:
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
L. NON-TIA ISSUES
Issue: Repair/Modification: Repair Schedule:
L.2. Security
a. Perimeter fencing was not installed around the compound or guy anchor foundations.
i. Install fencing around the compound and guy anchor foundations to ensure security of assets and provide protection to anchor foundations.
0-1 year $9,000
Sub Total: $9,000
Total: $9,000
OTHER CONSTRUCTION COSTS
Item:
a. Permits / Application Fees $1,000
b. Post Modification Inspection Report $2,000
c. Mobilization Costs $1,500
Sub Total: $4,500
Total: $4,500
GRAND TOTAL: $24,950
Fee:
Fee:
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANNEX A:
STEEL AND APPURTENANCE MAPPING
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Page Title Initials Page # (s) Notes Checklist & Notes
Tower Elevation Tower Section Elevation Transmission Cables
Waveguide
Antenna and Mount Sketch Photos
AEP
6-9 10-11 12-26 27-30
CHECKLIST
Latitude: Longitude:
Ground Elevation:
Site Address:
Tower ID Plate:
Existing Carriers/Site #:
Gate Combo:
Telephone Company:
Pedestal # and Location:
Power Company:
Meter # and Owner:
33.575406° (N 33° 34' 31.46")
4086-FT (VIA GOOGLE EARTH)
N. TOWER ROAD, BUCKEYE, AZ 85326 (MARICOPA COUNTY)
NONE OBSERVED
NONE OBSERVED
N/A
NONE OBSERVED
10 455 878 / CBP
CBP / AZ2143
N/A
-112.578769° (W 112° 34' 43.57")
Crew Leader:
Crew Member: ANDREW E. PROPST
Abbreviations: AGL: Above Ground Level B.C.: Bolt Circle BP: Bent Plate C-C: Center to Center C: Channel CNR: Could Not Record EW: Elliptical Waveguide FH: Foam Heliax
HCL: Hard Copper Line HSS: Hollow Structural Section L: Angle 2L: Double Angle MC: Metal Conduit M.E.: Minimum Edge MOD: Modification PL: Plate
RC: Rigid Conduit S.B.: Stitch Bolts Schl: Schifflerized Angle SM: Smooth Heliax SP: Spacing SR: Solid Rod TH: Thickness Tri: Triangular
KYLE C. EDWARDS, P.E., C.W.I.
NOTES
FCC#: N/A
Special Access Issues (Key Entry, Hidden/Unmarked Access, FM/TV on tower): ANDREA CULP
Compound Detail 2
(520) 300-3035
Ladder 3
MARICOPA COUNTY / UNKNOWN
AEP
AEP
AEP
AEP
AEP
AEP
AEP
AEP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
COMPOUND DETAIL
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Access Road Compound View CBP Equipment Shelter
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
LADDER
Climbing Ladder #1 Sketch
Description Ladder
# Height Width Step Rail (type & size) Rung (type & size) Safety (type & size)
13" 12" SR5
8"Ø SR7
8"Ø 3 8"Ø0'-80'1
Climbing Ladder #1 Photo
Climbing Ladder #1 Photo
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Description # Height Width Step Rail (type & size) Rung (type & size) Holes (size & spacing)
Waveguide Waveguide
WAVEGUIDE
7'-80'± 19" 48" N/A PL4"X19"X18" (6) 34"Ø, (2) 38"X1"1
2 7'-80'± 14" 36" C-LEG PL2"X14"X3
8"
Waveguide Ladder #1 Sketch
Waveguide Ladder #2 Sketch
Waveguide Ladder #1 Photo
Waveguide Ladder #2 Photo
(5) 14"Ø
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
T/ BASE PLATE
0'-0"± (REF.)
T/ TOWER
80'-0"±
℄ANT. 1
10'-6"
℄ANT. 2
20'-0"
℄ANT. 3
20'-3"
℄ANT. 5
32'-4"
℄ANT. 4
31'-0"
℄ANT. 6
35'-0"
℄ANT. 7
37'-0"
℄ANT. 9
54'-8"
℄ANT. 8
50'-0"
℄ANT. 10
60'-3"
℄ANT. 12
81'-0"
℄ANT. 14
88'-0"
℄ANT. 11
78'-6"
℄ANT. 13
82'-8"
T/ ANT.
98'-0"±
T/ L-ROD
82'-0"
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
TOWER ELEVATION
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
TOWER SECTION ELEVATION
BASE PLATE PHOTOSECTION _______________1 (0' - 20') PHOTO
MEMBER SIZES
Member
LEG
DIAG.
Size Bolts Gussets/Flange
SR 21
2"Ø
SR 1"Ø
12"Ø X 1"
PL12"X3"X3
8"
Face Width at Top ___________ Face Width at Bottom_________58"
58"
Min. Edge
1"(2) 58"Ø
HORIZ. SR 78"Ø
SUB-HORIZ. SR 78"Ø
(6) 11 4"Ø
PL12"X3"X3
8"
PL3"X4"X14"
1"(2) 58"Ø
2"(1) 58"Ø
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
TOWER SECTION ELEVATION
SECTION __________________2 (20' - 40')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________58"
58"
Member Size Bolts Gussets/FlangeMin. Edge
PHOTO PHOTO
LEG
DIAG.
SR 2"Ø
SR 78"Ø
8"Ø X 1"
PL12"X3"X3
8"1"(2) 58"Ø
HORIZ. SR 78"Ø
SUB-HORIZ. SR 34"Ø
(6) 58"Ø
PL12"X3"X3
8"
PL3"X4"X14"
1"(2) 58"Ø
2"(1) 58"Ø
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
TOWER SECTION ELEVATION
SECTION __________________3 (40' - 60')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________58"
58"
Member Size Bolts Gussets/FlangeMin. Edge
PHOTO PHOTO
LEG
DIAG.
SR 13
4"Ø
SR 78"Ø
8"Ø X 1"
PL12"X3"X3
8"1"(2) 58"Ø
HORIZ. SR 78"Ø
MOD. SR 34"Ø
(6) 58"Ø
PL12"X3"X3
8"
PL3"X4"X14"
1"(2) 58"Ø
2"(1) 58"Ø
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
TOWER SECTION ELEVATION
SECTION __________________4 (60' - 80')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________58"
58"
Member Size Bolts Gussets/FlangeMin. Edge
PHOTO PHOTO
LEG
DIAG.
SR 13
4"Ø
SR 34"Ø
8"Ø X 1"
PL12"X3"X3
8"1"(2) 58"Ø
HORIZ. SR 78"Ø
(6) 58"Ø
PL12"X3"X3
8"1"(2) 58"Ø
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
20°
260° 140°
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
TRANSMISSION CABLES
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Coax # Type/Style Start Height End Height Antenna Carrier Notes
PHX FIRE2 37'-0"
CITY OF PHOENIX
20'-3"
EW52 5'-0" 10'-6" 1
FH 78
FH 12
7'-0"
7'-0"
CBPFH 78
FH 12
FH 12
FH 12
FH 78
FH 78
FH 78
FH 78
7'-0" 7'-0" 7'-0"
7'-0"
7'-0" 7'-0"
7'-0"
7'-0"
20'-0" CBP
CBP
31'-0" CBP
35'-0"
49'-0" CBP
60'-3" CBP
PHX FIRE78'-0"
CBP
CBP
77'-0"
88'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
TRANSMISSION CABLES (CONTINUED)
PHX FIRE & WATER
32'-4"
FH 78
FH 78
7'-0" 7'-0"
FH 12
FH 78
7'-0" 7'-0"
Coax # Type/Style Start Height End Height Antenna Carrier Notes
CUT
PHX FIRE59'-0"
PHX FIRE & WATER73'-6"
60'-0" -
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 1 10'-6" B
Mount Type Azimuth
PIPE 75°
Antenna Manufacturer Antenna Model #
ANDREW UHX10-59-P6A
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW52
Antenna Elevation 10'-6"
Carrier______________CITY OF PHOENIX
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 2 20'-0" B
Mount Type Azimuth
PIPE 110°
Antenna Manufacturer Antenna Model #
RADIATION SYSTEMS P-22A96GF
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 20'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 3 20'-3" C
Mount Type Azimuth
PIPE 210°
Antenna Manufacturer Antenna Model #
RADIATION SYSTEMS P-22A72GF
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 20'-3"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 4 31'-0" A
Mount Type Azimuth
PIPE 90°
Antenna Manufacturer Antenna Model #
SCALA 94150-003
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 31'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 5 28'-10" C
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
UNKNOWN 3"Ø X 7' OMNI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 32'-4"
Carrier_______________PHX FIRE & WATER
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 6 35'-0" B
Mount Type Azimuth
PIPE 210°
Antenna Manufacturer Antenna Model #
UNKNOWN GRID 8' Ø
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 35'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 7 47'-0" A
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
ANDREW DB224
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 37'-0"
Carrier______________PHX FIRE
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 8 59'-0" B
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
ANDREW DB224
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 50'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna #
- 62'-0" B
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
TMA (#) / Model # (Coax Quantity) Size
Antenna Elevation
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 9 49'-0" A
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
RFI BA40-41-DIN
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 54'-9"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 10 60'-3" C
Mount Type Azimuth
PIPE 210°
Antenna Manufacturer Antenna Model #
UNKNOWN 8'Ø GRID DISH
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 60'-3"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 11 73'-6" A
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
UNKNOWN 2.5"Ø X 10' OMNI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 78'-6"
Carrier_______________PHX FIRE & WATER
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 12 76'-0" C
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
UNKNOWN 1"Ø X 8' OMNI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 81'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 13 77'-0" A
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
RFI BA40-41-DIN
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 82'-9"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 14 78'-0" B
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
ANDREW DB224-A
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 7/8
Antenna Elevation 88'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
PHOTOS
Partial Tower Elevation
Partial Tower Elevation
Partial Tower Elevation
Base of Tower
Tower Elevation
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
PHOTOS
CA Face
BC Face
AB Face
C Leg
B Leg
A Leg
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
PHOTOS
Typical Mod. Connection
Equipment Shelter by Others
Power Meter
Typical Mod. Connection
CBP Equipment Shelter
Top of Tower
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
WHITETANK MOUNTAIN
69922_85717
AZ2143
SEPTEMBER 9, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
PHOTOS
Cellular Receivers
Cellular Receivers
Inside CBP Shelter
CBP Fuel Cell Generator
HVAC Units
CBP Shelter Access
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANNEX B:
STRUCTURAL ANALYSIS
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
HGA Architects and Engineers 326 Tryon Road 420 5th Street North, Suite 100 Raleigh, NC 27603 Minneapolis, MN 55401 (919) 661-6351
(612) 758-4502 StructuresReview@tepgroup.net
Subject: Structural Analysis Report
Carrier Designation: U.S. Department of Homeland Security Site Number: AZ2143 Site Name: Whitetank Mountain
Engineering Firm Designation: TEP Project Number: 69922_85717
Site Data: N. Tower Road, Buckeye, Maricopa County, AZ 85326 Lat., Long.: 33.575406, -112.578769 (N 33° 34' 31.46'', W 112° 34' 43.57'') 80 Foot ± - Self Supporting Tower Dear Mr. Fiskum, Tower Engineering Professionals is pleased to submit this “Structural Analysis Report” to determine the structural integrity of the above mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC1: Existing + Proposed + Reserved Loading Insufficient Capacity Note: See Table 1 for the existing, proposed, and reserved loading
The analysis has been performed in accordance with the ANSI/TIA-222-G-2-2009 Structural Standard for Antenna Supporting Structures and Antennas – Addendum 2 and the 2012 International Building Code.
All modifications and equipment proposed in this report shall be installed in accordance with the appurtenances listed in Table 1 for the determined available structural capacity to be effective.
We at Tower Engineering Professionals appreciate the opportunity of providing our continuing professional services to you and HGA Architects and Engineers. If you have any questions or need further assistance on this or any other projects please give us a call.
Structural analysis prepared by: Nick Smith, E.I.
Structure Capacity Foundation Capacity
160.4% -
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
80-ft± Self Supporting Tower Structural…