GENERAL REPAIR REPORT-BM.pdf
PDF 8 MB Posted
- Solicitation number
- 6973GH-18-R-00153
About this file
GENERAL REPAIR REPORT-BM (pdf)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CONTRACTOR'S RELEASE FORM.doc | DOC document | |
| GENERAL REPAIR REPORT-TW.pdf | ||
| TOWER REPAIR REPORT-WT.pdf | ||
| SOW.pdf | ||
| EXPERIENCE INFO FORM.pdf | ||
| TOWER REPAIR REPORT-BM.pdf | ||
| TOWER REPAIR REPORT-BP.pdf | ||
| WD-AZ180032.pdf | ||
| GENERAL REPAIR REPORT-BP.pdf | ||
| 6973GH-18-R-00153.pdf | ||
| TOWER REPAIR REPORT-WT.pdf | ||
| GENERAL REPAIR REPORT-TW.pdf | ||
| WD-AZ180032.pdf | ||
| GENERAL REPAIR REPORT-BM.pdf | ||
| CONTRACTOR'S RELEASE FORM.doc | DOC document | |
| EXPERIENCE INFO FORM.pdf | ||
| SOW.pdf | ||
| TOWER REPAIR REPORT-BP.pdf | ||
| GENERAL REPAIR REPORT-BP.pdf | ||
| TOWER REPAIR REPORT-BM.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Structural Analysis and Condition Assessment for LMR Sites
Black Mountain, California (CA9998)
STRUCTURAL AND CONDITION ASSESSMENT
REPORT
September 15, 2016
SENSITIVE BUT UNCLASSIFIED (SBU) GSA Order #: GS-P-00-16-LY-7055 PROPERTY OF THE UNITED STATES GOVERNMENT GSA Contract #: GS-07-P-15-UC-D-7000
COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS PDN: EP-GS-P-00-16-LY-7055
DOCUMENT TO UNAUTHORIZED RECIPIENTS HGA Commission Number 2111-064-00
IS PROHIBITED
Do not remove this notice Properly destroy or return documents when no longer needed
420 North 5th Street, Suite 100 Minneapolis, Minnesota 55401
Tower Engineering Professionals
326 Tryon Road Raleigh, North Carolina 27603
STRUCTURAL AND CONDITION ASSESSMENT REPORT
FOR
[BLACK MOUNTAIN] CA9998
160’ SELF SUPPORTING TOWER
PALO VERDE, IMPERIAL COUNTY, CALIFORNIA
TEP # 69451_85599
Revision 0
Respectfully Submitted By:
Prepared For:
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Date: September 15, 2016
Stephen Fiskum, FAIA Tower Engineering Professionals
HGA Architects and Engineers 326 Tryon Road
420 5th Street North, Suite 100 Raleigh, NC 27603
Minneapolis, MN 55401 (919) 661-6351
(612) 758-4502 StructuresReview@tepgroup.net
Subject: Executive Summary
Tower Designation: Site Number: CA9998
Site Name: Black Mountain
Engineering Firm Designation: TEP Project Number: 69451_85599
Site Data: Black Mountain Road, Palo Verde, Imperial County, CA 92266
Lat., Long.: 33.052319, -114.827463
(N 33° 03' 08.35'', W 114° 49' 38.87”)
160 Foot ± – Self Supporting Tower
Tower Engineering Professionals (TEP) is pleased to provide this executive summary for the Phase I Scope of Work, which included a Maintenance and Condition Assessment, Capital Expenditure Table, Steel and Appurtenance
Mapping, and Structural Analysis for the above referenced site.
Maintenance and Condition Assessment
Overall Tower Condition (Excellent/Good/Average/Fair/Poor): Average*
Tower Type: 160-ft self supporting tower
Tower Age: Approximately 20-30 years**
Number of Guy Wires: N/A
Tower Access Road Condition: Good, no obstacles or issues encountered
A periodic inspection for the above referenced site was performed by Bryan Gilliam, C.W.I. and Cameron Torgent, E.I.
of TEP during the July 12, 2016 site visit. The inspection was in accordance with the ANSI/TIA-222-G-2005, Annex J:
Maintenance and Condition Assessment (Normative). TEP observed the following checklist items requiring some measure of possible or required corrective action: 1) Structure Condition, 2)Lighting, and 3) Antennas and Lines.
Refer to the Maintenance and Condition Assessment Report for specific details.
*TEP defines the tower conditions as follows:
Excellent - The tower has sufficient capacity to carry the existing loads. No modifications are required at this time. In addition, the tower has no maintenance issues of note and doesn’t require maintenance repairs at this time.
Good - The tower has sufficient capacity to carry the existing loads. No modifications are required at this time. However, the tower has some maintenance issues of note that require attention.
Average - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the
ANSI/TIA-222-G standard for the existing loading. In addition, the tower may have minor maintenance issues of note that require attention.
Fair - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the
ANSI/TIA-222-G standard for the existing loading. In addition, the tower has maintenance issues of note that require attention. Based on the itemized estimate in our Capital Expenditure Table, modifying the existing tower may be the most cost effective solution.
Poor - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the
ANSI/TIA-222-G standard for the existing loading. In addition, the tower has maintenance issues of note that require attention. Based on the itemized estimate in our Capital Expenditure Table and/or the condition of the tower, a full tower replacement may be the best solution.
**Tower Age was estimated based on tower identification tags, tower manufacturer information, tower research, type and condition of tower components, and/or historical site images
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP Project Number 69451_85599 September 15, 2016
CA9998 - Black Mountain
326 Tryon Road, Raleigh, NC 27603 (o) 919-661-6351 (f) 919-661-6350 www.tepgroup.net
Condition Assessment of Non-Tower Assets
During the site visit, TEP conducted a visual inspection of all Non-Tower Owned Assets. TEP did not find any non-tower assets that require urgent corrective repairs. However, TEP recommends regular inspection and maintenance by licensed professionals based on manufacturer specifications. Refer to Section L of the Maintenance and Condition
Assessment Report for any applicable additional information.
Asset Type Coordinates Condition Notes
Estimated
Remaining
Life
Shelter/
Roof 1 Prefab
33.052356, -114.827464 Average
Floor panels are damaged, no major structural issues observed 5-10 years
Shelter 1
Access
Single
Door
33.052356, -114.827464 Good
Located on north side of shelter, no major issues observed 10+ years
HVAC Unit Through
Wall
33.052356, -114.827464 Good
Bard manufacturer tag, appears to be working properly 10+ years
Shelter 2 Molded
Plastic
33.052289, -114.827400 Good
Vertex Plastics, Inc. manufacturer tag, appears to be in good condition, no major issues observed
10+ years
Shelter 2
Access
Single
Door
33.052289, -114.827400 Good
Located on east side of shelter, no major issues observed 10+ years
A/C Unit Through
Wall
33.052289, -114.827400 Good
Frigidaire manufacturer tag, appears to be working properly 10+ years
Power
Supply 1
Power
Meter
33.052411, -114.827553 Good
Located on utility pole, marked “General
Electric”, appears to be working properly 10+ years
Power
Supply 2
Power
Meter
33.052411, -114.827553 Good
Located on utility pole, marked “Itron”, appears to be working properly 10+ years
Power
Supply 3 Generator
33.052258, -114.827392 Good
Hydrogen fuel cell, marked “Reli On”, appears to be working properly 10+ years
Power
Supply 4 Generator
33.052336, -114.827525 Good
Marked “Kohler Power System”, appears to be working properly 10+ years
Power
Supply 5
Solar
Panel
33.052303, -114.827522 Good Appears to be working properly 10+ years
Gas
Source Fuel Tank
33.052350, -114.827456 Good No major issues visible 10+ years
Cellular
Receivers
- - Good
Shelters house various units associated with communication equipment, no major issues of note
10+ years
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Capital Expenditure Table
A cost estimate of $69,650 was provided to cover repairs and additional inspections as recommended in the
Maintenance and Condition Assessment Report and the Structural Analysis Report. The recommended repair schedule ranges from 6 months to 5 years. Also note that this estimate does not include any foundation reinforcements that may be required. TEP cannot say with certainty that modifying the existing tower would be more cost effective than a replacement without completing a Structural Modification Design Analysis. Refer to the
Capital Expenditure Table for details. For itemized repairs, refer to the Capital Expenditure Table for details. TEP estimated a ROM cost for full tower replacement would range from approximately $160,000 for a 100-ft self supporting tower to $250,000 for a 200-ft self supporting tower. These estimates do not include pricing for site specific costs related to zoning, permitting, environmental studies, etc.
Steel and Appurtenance Mapping
The original design criteria were unavailable for review. A Steel and Appurtenance Mapping was performed in order to obtain the necessary tower and appurtenance loading information needed to conduct the Structural Analysis for this site. The antennas recorded during our Steel and Appurtenance Mapping are depicted in the table below. TEP denoted the owner of the equipment under the “Owner/Tenant” column based on information available on site.
Refer to the Steel and Appurtenance Mapping Report for additional detail.
Elevation
(ft) Qty Antenna Model
Mount
Type
Owner/
Tenant
168.0 3 2.8”Ø x 20’ Tapered Omni (3) Standoff CBP
145.0 1 CWT RuralConnect Direct CBP
147.0 1 RFI BA40-41-DIN Sidearm CBP
127.0 1 RFI BA40-41-DIN Sidearm CBP
111.0 2 2.8”Ø x 20’ Tapered Omni (2) Standoff CBP
81.7 1 Andrew DB222-A Sidearm Fish & Game
77.0 1 Andrew HP6-71W-P3A/C Pipe CBP
63.5 1 Andrew PL10-71GE-1 Pipe CBP
63.3 1 Andrew PL10-71GE-1 Pipe CBP
51.0 1 Andrew HP6-71W-P3A/C Pipe CBP
51.0 1 Andrew HPX8-71W-P1A Pipe CBP
51.0 1 Mark P-9LA96GN Pipe CBP
41.0 1 6-Element Yagi Sidearm CBP
41.0 1 Kathrein 94150-003 Pipe CBP
30.5 1 Radiowaves G6-2.4 Pipe CBP
18.5 1 Andrew HPX8-71W-P1A Pipe CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Structural Analysis
The Structural Analysis report outlines overstresses in the tower legs from 20’ to 40’ elevations and diagonal bracing from 0’ to 80’ elevations. TEP believes that the majority of the overstresses can be attributed to the more stringent loading and analysis criteria as required by the latest ANSI/TIA-222-G-2-2009 Standard, as compared to previous versions of the TIA Standard for which the tower was originally designed. Based on our analysis we have determined the tower stress level for each controlling component, under the following load case, to be:
LC1: Existing Equipment Insufficient Capacity Note: See Table 1 for the existing loading
Thank you for the opportunity to provide this service for you. If you have any questions or comments, please contact our office.
Component % Capacity
Leg (T7) 131.7
Diagonal (T6) >200.0
Top Girt (T1) 3.5
Bolt Checks 187.8
Anchor Rods 79.7
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
MASTER TABLE OF CONTENTS
���� MAINTENANCE AND CONDITION ASSESSMENT
���� CAPITAL EXPENDITURE TABLE
���� ANNEX A: STEEL AND APPURTENANCE MAPPING
���� ANNEX B: STRUCTURAL ANALYSIS
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
MAINTENANCE AND CONDITION ASSESSMENT
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Date: September 15, 2016
HGA Architects and Engineers 326 Tryon Road
420 5th Street North, Suite 100 Raleigh, NC 27603
Minneapolis, MN 55401 (919) 661-6351
(612) 758-4502 StructuresReview@tepgroup.net
Subject: Maintenance and Condition Assessment Report
Tower Designation: Site Number: CA9998
Site Name: Black Mountain
Engineering Firm Designation: TEP Project Number: 69451_85599
Site Data: Black Mountain Road, Palo Verde, Imperial County, CA 92266
Lat., Long.: 33.052319, -114.827463
(N 33° 03' 08.35”, W 114° 49' 38.87”)
160 Foot ± – Self Supporting Tower
Dear Mr. Fiskum, Tower Engineering Professionals (TEP) completed a periodic inspection for the above referenced site. The onsite investigation was performed by Bryan Gilliam, C.W.I. and Cameron Torgent, E.I. of TEP during the July 12, 2016 site visit.
The inspection was in accordance with the ANSI/TIA-222-G-2005, Annex J: Maintenance and Condition Assessment
(Normative), including all addendums (addendums TIA-222-G-1 2007 and TIA 222-G-2 2009); the checklist can be found on pages 3 thru 8 of this report.
Observations and recommendations are listed herein. The inspection included observation of the tower components and CBP owned assets. For the purpose of this inspection, the tower legs were named by letter according to the magnetic azimuth defined by a line from the center of tower to the leg. “A” leg is the leg closest to magnetic north, followed clockwise by “B” and “C.”
Thank you for the opportunity to provide this service for you. If you have any questions or comments, please contact our office.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Self Supporting Tower Maintenance and Condition Assessment Report September 15, 2016
TEP Project Number 69451_85599 CA9998 - Black Mountain
TABLE OF CONTENTS
1) ANSI/TIA-222-G-MAINTENANCE AND CONDITION ASSESSMENT
2) SUMMARY
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANSI/TIA-222-G MAINTENANCE AND CONDITION ASSESSMENT
A. STRUCTURE CONDITION
A.1. Damaged members (legs and bracing)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Surface corrosion observed on leg member at 1-ft on B-leg. Bent top girt member observed at 160-ft on the CA face. Surface corrosion observed on C-leg at base. See executive summary for details and recommendations.
A.2. Loose members
Okay Possible Improvement Needs Repair Not Applicable
Notes:
A.3. Missing members
Okay Possible Improvement Needs Repair Not Applicable
Notes:
A.4. Climbing facilities, platforms, catwalks – all secure
Okay Possible Improvement Needs Repair Not Applicable
Notes: Missing step peg at 30.5-ft at B-leg. (2) Missing step pegs at 29.25-ft on C-leg. (6) Missing step pegs at 60-ft. Missing step peg at
61-ft on A-leg. See executive summary for details and recommendations.
A.5. Loose and/or missing bolts and/or nut locking devices
Okay Possible Improvement Needs Repair Not Applicable
Notes: Missing nut locking devices on C-leg at 120-ft. Undersized diagonal bolt at 40-ft on B-leg. See executive summary for details and recommendations.
A.6. Visible cracks in welded connections
Notes:
B. FINISH
B.1. Paint and/or galvanizing condition
Notes:
B.2. Rust and/or corrosion condition including mounts and accessories
Okay Possible Improvement Needs Repair Not Applicable
Notes:
B.3. FAA or ICAO color marking conditions
Okay Possible Improvement Needs Repair Not Applicable
Notes:
B.4. Water collection in members (to be remedied, e.g., unplug drain holes, etc.)
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
C. LIGHTING
C.1. Conduit, junction boxes, and fasteners (weather tight and secure)
Notes:
C.2. Drains and vents openings (unobstructed)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.3. Wiring Condition
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.4. Light lenses
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.5. Bulb condition
Okay Possible Improvement Needs Repair Not Applicable
Notes: Top of tower beacon on the A-leg at 160-ft is malfunctioning. See executive summary for details and recommendations.
C.6.a. Controllers functioning (Flasher)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
C.6.b. Controllers functioning (Photo control)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Top of tower beacon on the A-leg at 160-ft is malfunctioning.
C.6.c. Controllers functioning (Alarms)
D. GROUNDING
D.1. Connections
Notes:
D.2. Corrosion
Okay Possible Improvement Needs Repair Not Applicable
Notes:
D.3. Lightning protection (secured to structure)
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E. ANTENNAS AND LINES
E.1. Antenna condition
Notes:
E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Unused antenna mount on A leg at 25-ft. Unused antenna mount on CA face at 26-ft. Unused antenna mounts on BC face at
87-ft See executive summary for details and recommendations.
E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Small areas of surface corrosion observed intermittently throughout waveguide on AB-face. See executive summary for details and recommendations.
E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)
Okay Possible Improvement Needs Repair Not Applicable
Notes: Missing snap-in observed at 50-ft on CA face. See executive summary for details and recommendations.
E.5. Secured to structure
F. OTHER APPURTENANCES (WALKWAYS, PLATFORMS, SENSORS, FLOODLIGHTS, ETC.)
F.1. Condition
Notes:
F.2. Secured to structure
G. INSULATOR CONDITION
G.1. Cracking and chipping
Notes:
G.2. Cleanliness of insulators
Okay Possible Improvement Needs Repair Not Applicable
Notes:
G.3. Spark gaps set properly
Okay Possible Improvement Needs Repair Not Applicable
Notes:
G.4. Isolation transformer condition
Okay Possible Improvement Needs Repair Not Applicable
Notes:
G.5. Bolts and connection secure
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
H. GUYS
H.1. Strand condition (corrosion, breaks, nicks, kinks, etc.)
Notes:
H.2.a. Guy Hardware Conditions (Turnbuckles or equivalent (secure and safety properly applied)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.b. Guy Hardware Conditions (Cable thimbles properly in place (if required))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.c. Guy Hardware Conditions (Service sleeves properly in place (if required))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.i. Guy Hardware Conditions (Cable connectors (end fittings) (Cable clamps applied properly and bolts tight))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.ii. Guy Hardware Conditions (Cable connectors (end fittings) (Wire serving properly applied))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.iii. Guy Hardware Conditions (Cable connectors (end fittings) (No signs of slippage or damaged strands))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.iv. Guy Hardware Conditions (Cable connectors (Preformed wraps – properly applied, fully wrapped, & sleeve in place))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.v. Guy Hardware Conditions (Cable connectors (end fittings) (Poured sockets secure and showing no separation))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.2.d.vi. Guy Hardware Conditions (Cable connectors (Shackles, bolts, pins, and cotter pins secure and in good condition))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.3. Guy tensions
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.4. Measure guy tensions
Okay Possible Improvement Needs Repair Not Applicable
Notes:
H.5. Record temperature, wind speed and wind direction
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
I. CONCRETE FOUNDATIONS
I.1.a. Ground condition (Settlement, movement or earth cracks)
Notes:
I.1.b. Ground condition (Erosion)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.1.c. Ground condition (Site condition (standing water, drainage, trees, etc.))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.2.a. Anchorage condition (Nuts and/or nut locking device (tightened))
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.2.b. Anchorage condition (Grout condition)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.2.c. Anchorage condition (Anchorages and/or anchor rod condition)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.a. Concrete condition (Cracking, spalling, or splitting)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.b. Concrete condition (Chipped or broken concrete)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.c. Concrete condition (Honeycombing)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
I.3.d. Concrete condition (Low spots to collect moisture)
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
J. GUYED MAST ANCHORS
J.1. Settlement, movement or earth cracks
Notes:
J.2. Backfill heaped over concrete for water shedding
Okay Possible Improvement Needs Repair Not Applicable
Notes:
J.3. Anchor rod condition below earth (Maintain required structural capacity of anchor during exploration.)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
J.4. Corrosion control measures (galvanizing, coating, concrete encasement, cathodic protection systems, etc.)
Okay Possible Improvement Needs Repair Not Applicable
Notes:
J.5. Anchor heads clear of earth
K. TOWER ALIGNMENT
K.1. Tower Plumb and Twist
Notes: Tower twist and plumb was not measured as a part of this scope of work.
L. NON-TIA RELATED ITEMS
L.1. Equipment Shelter
Notes:
L.2. Security
Okay Possible Improvement Needs Repair Not Applicable
Notes:
L.3. Other Equipment
Okay Possible Improvement Needs Repair Not Applicable
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
SUMMARY
Photograph Observations and Recommendations
Observation:
Surface corrosion observed on leg member at 1-ft on B-leg.
Recommendation:
Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Surface corrosion observed on C-leg at base.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
Bent top girt member observed at 160-ft on the CA face.
Replace damaged member.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
A.4. Climbing facilities, platforms, catwalks – all secure
Missing step peg at 30.5-ft at B-leg.
Replace with a new 5/8” dia. 7” long step peg.
(2) Missing step pegs at 29.25-ft on C-leg.
Replace with new 5/8” dia. 7” long step pegs.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
(6) Missing step pegs at 60-ft.
Replace with new 5/8” dia. 7” long step pegs.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
A.5. Loose and/or missing bolts and/or nut locking devices
Missing nut locking devices on C-leg at 120-ft.
Install nut locking devices. If necessary, re-install longer bolts to accommodate the use of nut locking devices.
Tighten all nuts per the AISC “turn of the nut” method.
A.5. Loose and/or missing bolts and/or nut locking devices
Undersized diagonal bolt at 40-ft on B-leg.
Install a new A325X 5/8” dia. diagonal bolt. Tighten nut per the AISC “turn of the nut” method. Install nut locking device on new bolt.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
C.5. Bulb condition
Top of tower beacon on the A-leg at 160-ft is malfunctioning.
Repair or replace beacon.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)
Unused antenna mount on A leg at 25-ft.
Removing the unused antenna mount will improve the overall structural capacity of the tower.
Unused antenna mount on CA face at 26-ft.
Unused antenna mount on BC face at 87-ft.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E.3 Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)
Small areas of surface corrosion observed intermittently throughout waveguide on AB-face.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)
Missing snap-in observed at 50-ft on CA face.
Reattach coax to tower.
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
CAPITAL EXPENDITURE TABLE
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANSI/TIA-222-G: CAPITAL EXPENDITURE TABLE
Job Name: CA9998 - Black Mountain
TEP Number: 69451_85599
A. STRUCTURAL CONDITION
Issue: Repair/Modification: Repair Schedule:
A.1. Damaged members (legs and bracing)
a. Surface corrosion observed on leg member at 1-ft on B-leg. i. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.
0-1 year $150
b. Surface corrosion observed on C-leg at base. ii. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.
0-1 year $100
c. Bent top girt member observed at 160-ft on the CA face. iii. Replace damaged member. 0-6 months $1,500
d. The following members were overstressed in the structural analysis:
iv. Complete repairs as specified in Structural Design
Drawings.
0-6 months $60,000
● Tower Legs from 20'-40'
● Tower Diagonals from 0'-80'
Sub Total: $61,750
A.4. Climbing facilities, platforms, catwalks – all secure
a. Missing step peg at 30.5-ft at B-leg. i. Replace with a new 5/8” dia. 7” long step peg. 0-1 year $50
b. (2) Missing step pegs at 29.25-ft on C-leg. ii. Replace with new 5/8” dia. 7” long step pegs. 0-1 year $75
c. (6) Missing step pegs at 60-ft. iii. Replace with new 5/8” dia. 7” long step pegs. 0-1 year $125
d. Missing step pegs at 61-ft on A-leg. iv. Replace with a new 5/8” dia. 7” long step peg. 0-1 year $50
Sub Total: $300
A.5. Loose and/or missing bolts and/or nut locking devices
a. Missing nut locking devices on C-leg at 120-ft. i. Install nut locking devices. If necessary, re-install longer bolts to accommodate the use of nut locking devices. Tighten all nuts per the AISC “turn of the nut” method.
0-6 months $150
b. Undersized diagonal bolt at 40-ft on B-leg. ii. Install a new A325X 5/8” dia. diagonal bolt. Tighten nut per the AISC “turn of the nut” method. Install nut locking devices on all new bolts.
0-6 months $350
Sub Total: $500
Total: $62,550
B. FINISH
NO DEFICIENCIES WERE IDENTIFIED
C. LIGHTING
Issue: Repair/Modification: Repair Schedule:
C.5. Bulb condition
a. Top of tower beacon on the A-leg at 160-ft is malfunctioning. i. Repair or replace beacon. 0-1 year $1,500
Sub Total: $1,500
Total: $1,500
D. GROUNDING
NO DEFICIENCIES WERE IDENTIFIED
*Items that don't require attention were omitted from this list of itemized modification costs. For a full itemized list of everything that was assessed during our site visit please reference the Maintenance and Condition Assessment.
Fee:
Fee:
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
E. ANTENNAS AND LINES
Issue: Repair/Modification: Repair Schedule:
E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)
a. Unused antenna mount on A leg at 25-ft. i. Removing the unused antenna mount will improve the overall structural capacity of the tower.
0-5 years $150
b. Unused antenna mount on CA face at 26-ft. ii. Removing the unused antenna mount will improve the overall structural capacity of the tower.
0-5 years $250
c. Unused antenna mount on BC face at 87-ft. iii. Removing the unused antenna mount will improve the overall structural capacity of the tower.
0-5 years $250
Sub Total: $650
E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)
a. Small areas of surface corrosion observed intermittently throughout waveguide on AB-face.
i. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing
0-1 year $400
Sub Total: $400
E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)
a. Missing snap-in observed at 50-ft on CA face. i. Reattach coax to tower. 0-1 year $50
Sub Total: $50
Total: $1,100
F. OTHER APPURTENANCES (WALKWAYS, PLATFORMS, SENSORS, FLOODLIGHTS, ETC.)
NO DEFICIENCIES WERE IDENTIFIED
G. INSULATOR CONDITION
NO DEFICIENCIES WERE IDENTIFIED
H. GUYS
NO DEFICIENCIES WERE IDENTIFIED
I. CONCRETE FOUNDATIONS
NO DEFICIENCIES WERE IDENTIFIED
J. GUYED MAST ANCHORS
NO DEFICIENCIES WERE IDENTIFIED
K. TOWER ALIGNMENT
NO DEFICIENCIES WERE IDENTIFIED
L. NON-TIA ISSUES
NO DEFICIENCIES WERE IDENTIFIED
OTHER CONSTRUCTION COSTS
Item:
a. Permits / Application Fees $1,000
b. Post Modification Inspection Report $2,000
c. Mobilization Costs $1,500
Sub Total: $4,500
Total: $4,500
GRAND TOTAL: $69,650
Fee:
Fee:
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
ANNEX A:
STEEL AND APPURTENANCE MAPPING
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Page Title Initials Page # (s) Notes Checklist & Notes
Tower Elevation Tower Section Elevation Transmission Cables
Antenna and Mount Sketch Photos
CJT
6-13 14-15 16-37 38-41
CHECKLIST
Latitude: Longitude:
Ground Elevation:
Site Address:
Tower ID Plate:
Existing Carriers/Site #:
Gate Combo:
Telephone Company:
Pedestal # and Location:
Power Company:
Meter # and Owner:
33.052319° (N 33° 03' 08.35")
2077-FT (VIA GOOGLE EARTH)
BLACK MOUNTAIN ROAD, PALO VERDE, CA 92266 (IMPERIAL COUNTY)
NONE OBSERVED
NONE OBSERVED
NONE OBSERVED
IMPERIAL IRRIGATION DISTRICT
78 603 679 / CBP
CBP / CA9998
N/A
-114.827463° (W 114° 49' 38.87")
Crew Leader:
Crew Member: CAMERON J. TORGENT, E.I.
Abbreviations: AGL: Above Ground Level B.C.: Bolt Circle BP: Bent Plate C-C: Center to Center C: Channel CNR: Could Not Record EW: Elliptical Waveguide FH: Foam Heliax
HCL: Hard Copper Line HSS: Hollow Structural Section L: Angle 2L: Double Angle MC: Metal Conduit M.E.: Minimum Edge MOD: Modification PL: Plate
RC: Rigid Conduit S.B.: Stitch Bolts Schl: Schifflerized Angle SM: Smooth Heliax SP: Spacing SR: Solid Rod TH: Thickness Tri: Triangular
BRYAN J. GILLIAM, C.W.I.
NOTES
FCC#: N/A
Special Access Issues (Key Entry, Hidden/Unmarked Access, FM/TV on tower): CONTACT RICHARD KNIGGE
Compound Detail 2
(928) 341-6622 OR (520) 909-7602
Ladder 3
CJT
CJT
CJT
CJT
CJT
CJT
CJT
CJT
Waveguide
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
COMPOUND DETAIL
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Access Road Compound View CBP Equipment Shelter
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
LADDER
Climbing Ladder #1 Sketch
Description Ladder
# Height Width Step Rail (type & size) Rung (type & size) Safety (type & size)
Pegs Pegs Pegs
14" 7" 7" 7"
15" 15" 15" 15"
PL11
2"x14"
A LEG
B LEG
C LEG
8"Ø
8"Ø
8"Ø
8"Ø
8"Ø32"-163'1
-20'-80' -20'-80' -20'-160'
Climbing Ladder #1 Photo
Climbing Ladder #2 Photo
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Description # Height Width Step Rail (type & size) Rung (type & size) Holes (size & spacing)
Waveguide Waveguide
WAVEGUIDE
0'-161'± 311 2" 48" L11
2"x11 2"x18" PL11
2"x38" (29) 14"Ø1 2 21'-62'± 121
2" 48" L2"x2"x14" L2"x2"x14"
Waveguide Ladder #1 Sketch Waveguide Ladder #1 Photo
Waveguide Ladder #2 Photo
(6) 716"Ø
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER ELEVATION
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
BASE PLATE PHOTOSECTION _______________1 (0' - 20') PHOTO
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________23'-0"
21'-15 16"
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P5.5"Øx0.377"TH* L4"x4"x14"TH
(6) 1"Ø PL91
2"x91
2"x11
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
1"
*LEG MOD (0'-20'): L6"x6"x5
16"TH W/
ONE CONTINUOUS WELD TO PIPE
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________2 (20' - 40')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________21'-15
16" 19'-29
16"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P5.5"Øx0.265"TH L31
2"x31 2"x14"TH
(4) 1"Ø PL91
2"x91
2"x11
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
1"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________3 (40' - 60')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________19'-29
16" 17'-37
8"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P5.5"Øx0.386"TH L3"x3"x14"TH
(4) 1"Ø PL91
2"x91
2"x11
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________4 (60' - 80')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________17'-37
8" 15'-51
8"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P5.5"Øx0.284"TH L3"x3"x14"TH
(4) 1"Ø PL91
2"x91
2"x11
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________5 (80' - 100')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________15'-51
8" 13'-67
16"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P4.5"Øx0.345"TH L21
2"x21 2"x14"TH
(4) 1"Ø PL91
2"x91
2"x11
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________6 (100' - 120')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________13'-67
16" 11'-711
16"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P3.5"Øx0.344"TH L21
2"x21 2"x14"TH
(4) 78"Ø PL7"x7"x1"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________7 (120' - 140')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________11'-711
16" 9'-9"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P2.9"Øx0.314"TH L21
2"x21 2"x14"TH
(4) 34"Ø PL6"x6"x3
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
1"
GIRT L21
2"x21
2"x316"TH 1
4"TH--(1) 58"Ø 1"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TOWER MAPPING
Site Name
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TOWER SECTION ELEVATION
SECTION __________________8 (140' - 160')
MEMBER SIZES
Face Width at Top ___________ Face Width at Bottom_________9'-9"
9'-9"
PHOTO PHOTO
Member
LEG
DIAG.
Size Bolts Gussets/Flange
P2.9"Øx0.205"TH L2"x2"x14"TH
(4) 58"Ø PL5"x5"x3
4"TH
4"TH
Stitch Bolt
(1) 58"Ø(1) 58"Ø
Min. Edge
1"
GIRT L21
2"x21
2"x316"TH 1
4"TH--(1) 58"Ø 1"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
TRANSMISSION CABLES
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Coax # Type/Style Start Height End Height Antenna Carrier Notes
CBP2 77'-0"
CBP
41'-0" 4 CBP3
EW 77 9'-0" 51'-0" 7 CBP
EW 77 9'-0"
FH 12 9'-0"
CBP5 121'-6"
CBP
141'-6" 15 CBP6
FH 12 9'-0" 41'-0" 3 CBP
FH 78 9'-0"
FH 78 9'-0"
CBP7 145'-0" 16
51'-0" 6 CBP8
SM 516"Ø 9'-0"
EW 77 9'-0"
CBP10 157'-6"
CBP
157'-6" 18 CBP11
EW 77 9'-0" 18'-6" 1 CBP
FH 78 9'-0"
FH 78 9'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
TRANSMISSION CABLES (CONTINUED)
Coax # Type/Style Start Height End Height Antenna Carrier Notes
CBP13 100'-6"
CBP
51'-0" 5 CBP14
FH 78 9'-0" 100'-6" 12 CBP
FH 78 9'-0"
FH 78 9'-0"
CBP16 157'-6"
FISH & GAME
161'-0" - CBP17
FH 12 9'-0" 81'-8" 11
FH 78 9'-0"
1"Ø M.C. 9'-0"
CBP18 63'-4" 8
63'-6" 9 CBP19
EW 77 21'-0"
EW 77 21'-0"
20 CBPFH 12 21'-0" 30'-6" 2 CBP
CONDUIT FOR LIGHTS
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 1 18'-6" B
Mount Type Azimuth
PIPE 140°
Antenna Manufacturer Antenna Model #
ANDREW HPX8-71W-P1A
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW 77
Antenna Elevation 18'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation
Mount Elevation LegAntenna #
- 25'-0" A
Mount Type Azimuth
DIRECT N/A
Antenna Manufacturer Description
- P4.5"Øx6.5'
Offset (Coax Quantity) Size 11" N/A
Antenna Elevation
Carrier______________CBP
Photo
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation
Mount Elevation FaceAntenna #
- 26'-0" CA
Mount Type Azimuth
DIRECT N/A
Antenna Manufacturer Description
- HSS 6"x6"x20'
TMA (#) / Model # (Coax Quantity) Size N/A N/A
Antenna Elevation
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Photo
Mount Elevation LegAntenna # 2 30'-6" B
Mount Type Azimuth
PIPE 170°
Antenna Manufacturer Antenna Model #
RADIOWAVES G6-2.4
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 12
Antenna Elevation 30'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 3 41'-0" B
Mount Type Azimuth
PIPE 170°
Antenna Manufacturer Antenna Model #
KATHREIN 94150-003
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 12
Antenna Elevation 41'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 4 41'-0" C
Mount Type Azimuth
SIDEARM 180°
Antenna Manufacturer Antenna Model #
UNKNOWN 6 ELEMENT YAGI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 12
Antenna Elevation 41'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 5 51'-0" A
Mount Type Azimuth
SIDEARM 0°
Antenna Manufacturer Antenna Model #
MARK ANTENNAS P-9LA96GN
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 78
Antenna Elevation 51'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 6 51'-0" B
Mount Type Azimuth
PIPE 150°
Antenna Manufacturer Antenna Model #
ANDREW HPX8-71W-P1A
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW 77
Antenna Elevation 51'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 7 51'-0" C
Mount Type Azimuth
PIPE 240°
Antenna Manufacturer Antenna Model #
ANDREW HP6-71W-P3A/C
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW 77
Antenna Elevation 51'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 8 63'-4" A
Mount Type Azimuth
PIPE 0°
Antenna Manufacturer Antenna Model #
ANDREW PL10-71GE-1
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW 77
Antenna Elevation 63'-4"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 9 63'-6" B
Mount Type Azimuth
PIPE 135°
Antenna Manufacturer Antenna Model #
ANDREW PL10-71GE-1
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW 77
Antenna Elevation 63'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 10 77'-0" C
Mount Type Azimuth
PIPE 240°
Antenna Manufacturer Antenna Model #
ANDREW D6F-5-GR
TMA (#) / Model # (Coax Quantity) Size
N/A (1) EW 77
Antenna Elevation 77'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 11 81'-8" B
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
ANDREW DB222-A
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 12
Antenna Elevation 81'-8"
Carrier______________FISH & GAME
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation
Mount Elevation FaceAntenna #
- 87'-0" BC
Mount Type Azimuth
DIRECT N/A
Antenna Manufacturer Description
- HSS 31
2"x31 2"x131
2' TMA (#) / Model # (Coax Quantity) Size
N/A N/A
Antenna Elevation
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 12 102'-0" A
Mount Type Azimuth
STANDOFF N/A
Antenna Manufacturer Antenna Model # UNKNOWN 2.8"Øx20' TAPERED OMNI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 78
Antenna Elevation 100'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 13 102'-0" B
Mount Type Azimuth
STANDOFF N/A
Antenna Manufacturer Antenna Model # UNKNOWN 2.8"Øx20' TAPERED OMNI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 78
Antenna Elevation 100'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 14 121'-6" B
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
RFI BA40-41-DIN
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 78
Antenna Elevation 121'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 15 141'-6" B
Mount Type Azimuth
SIDEARM N/A
Antenna Manufacturer Antenna Model #
RFI BA40-41-DIN
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 78
Antenna Elevation 141'-6"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 16 - A
Mount Type Azimuth
DIRECT 330°
Antenna Manufacturer Antenna Model # RURAL CONNECT 9"x11"x51
2" TMA (#) / Model # (Coax Quantity) Size
N/A (1) SM 516"Ø
Antenna Elevation 145'-0"
Carrier______________CBP
PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
TEP #
Client # Date Page of
BLACK MOUNTAIN
69451_85599
CA9998
SEPTEMBER 15, 2016
ANTENNA AND MOUNT SKETCH
326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net
Side Elevation Plan View
Mount Elevation LegAntenna # 17 157'-6" A
Mount Type Azimuth
STANDOFF N/A
Antenna Manufacturer Antenna Model # UNKNOWN 2.8"Øx20' TAPERED OMNI
TMA (#) / Model # (Coax Quantity) Size
N/A (1) FH 78
Antenna Elevation 157'-6"
Carrier______________CBP