About this file

GENERAL REPAIR REPORT-BM (pdf)

View the file

Other files

File Type Posted
CONTRACTOR'S RELEASE FORM.doc DOC document
GENERAL REPAIR REPORT-TW.pdf PDF
TOWER REPAIR REPORT-WT.pdf PDF
SOW.pdf PDF
EXPERIENCE INFO FORM.pdf PDF
TOWER REPAIR REPORT-BM.pdf PDF
TOWER REPAIR REPORT-BP.pdf PDF
WD-AZ180032.pdf PDF
GENERAL REPAIR REPORT-BP.pdf PDF
6973GH-18-R-00153.pdf PDF
TOWER REPAIR REPORT-WT.pdf PDF
GENERAL REPAIR REPORT-TW.pdf PDF
WD-AZ180032.pdf PDF
GENERAL REPAIR REPORT-BM.pdf PDF
CONTRACTOR'S RELEASE FORM.doc DOC document
EXPERIENCE INFO FORM.pdf PDF
SOW.pdf PDF
TOWER REPAIR REPORT-BP.pdf PDF
GENERAL REPAIR REPORT-BP.pdf PDF
TOWER REPAIR REPORT-BM.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Structural Analysis and Condition Assessment for LMR Sites

Black Mountain, California (CA9998)

STRUCTURAL AND CONDITION ASSESSMENT

REPORT

September 15, 2016

SENSITIVE BUT UNCLASSIFIED (SBU) GSA Order #: GS-P-00-16-LY-7055 PROPERTY OF THE UNITED STATES GOVERNMENT GSA Contract #: GS-07-P-15-UC-D-7000

COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS PDN: EP-GS-P-00-16-LY-7055

DOCUMENT TO UNAUTHORIZED RECIPIENTS HGA Commission Number 2111-064-00

IS PROHIBITED

Do not remove this notice Properly destroy or return documents when no longer needed

420 North 5th Street, Suite 100 Minneapolis, Minnesota 55401

Tower Engineering Professionals

326 Tryon Road Raleigh, North Carolina 27603

STRUCTURAL AND CONDITION ASSESSMENT REPORT

FOR

[BLACK MOUNTAIN] CA9998

160’ SELF SUPPORTING TOWER

PALO VERDE, IMPERIAL COUNTY, CALIFORNIA

TEP # 69451_85599

Revision 0

Respectfully Submitted By:

Prepared For:

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Date: September 15, 2016

Stephen Fiskum, FAIA Tower Engineering Professionals

HGA Architects and Engineers 326 Tryon Road

420 5th Street North, Suite 100 Raleigh, NC 27603

Minneapolis, MN 55401 (919) 661-6351

(612) 758-4502 StructuresReview@tepgroup.net

Subject: Executive Summary

Tower Designation: Site Number: CA9998

Site Name: Black Mountain

Engineering Firm Designation: TEP Project Number: 69451_85599

Site Data: Black Mountain Road, Palo Verde, Imperial County, CA 92266

Lat., Long.: 33.052319, -114.827463

(N 33° 03' 08.35'', W 114° 49' 38.87”)

160 Foot ± – Self Supporting Tower

Tower Engineering Professionals (TEP) is pleased to provide this executive summary for the Phase I Scope of Work, which included a Maintenance and Condition Assessment, Capital Expenditure Table, Steel and Appurtenance

Mapping, and Structural Analysis for the above referenced site.

Maintenance and Condition Assessment

Overall Tower Condition (Excellent/Good/Average/Fair/Poor): Average*

Tower Type: 160-ft self supporting tower

Tower Age: Approximately 20-30 years**

Number of Guy Wires: N/A

Tower Access Road Condition: Good, no obstacles or issues encountered

A periodic inspection for the above referenced site was performed by Bryan Gilliam, C.W.I. and Cameron Torgent, E.I.

of TEP during the July 12, 2016 site visit. The inspection was in accordance with the ANSI/TIA-222-G-2005, Annex J:

Maintenance and Condition Assessment (Normative). TEP observed the following checklist items requiring some measure of possible or required corrective action: 1) Structure Condition, 2)Lighting, and 3) Antennas and Lines.

Refer to the Maintenance and Condition Assessment Report for specific details.

*TEP defines the tower conditions as follows:

Excellent - The tower has sufficient capacity to carry the existing loads. No modifications are required at this time. In addition, the tower has no maintenance issues of note and doesn’t require maintenance repairs at this time.

Good - The tower has sufficient capacity to carry the existing loads. No modifications are required at this time. However, the tower has some maintenance issues of note that require attention.

Average - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the

ANSI/TIA-222-G standard for the existing loading. In addition, the tower may have minor maintenance issues of note that require attention.

Fair - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the

ANSI/TIA-222-G standard for the existing loading. In addition, the tower has maintenance issues of note that require attention. Based on the itemized estimate in our Capital Expenditure Table, modifying the existing tower may be the most cost effective solution.

Poor - The tower does not have sufficient capacity to carry the existing loads. Modifications will be required to bring the tower into compliance with the

ANSI/TIA-222-G standard for the existing loading. In addition, the tower has maintenance issues of note that require attention. Based on the itemized estimate in our Capital Expenditure Table and/or the condition of the tower, a full tower replacement may be the best solution.

**Tower Age was estimated based on tower identification tags, tower manufacturer information, tower research, type and condition of tower components, and/or historical site images

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP Project Number 69451_85599 September 15, 2016

CA9998 - Black Mountain

326 Tryon Road, Raleigh, NC 27603 (o) 919-661-6351 (f) 919-661-6350 www.tepgroup.net

Condition Assessment of Non-Tower Assets

During the site visit, TEP conducted a visual inspection of all Non-Tower Owned Assets. TEP did not find any non-tower assets that require urgent corrective repairs. However, TEP recommends regular inspection and maintenance by licensed professionals based on manufacturer specifications. Refer to Section L of the Maintenance and Condition

Assessment Report for any applicable additional information.

Asset Type Coordinates Condition Notes

Estimated

Remaining

Life

Shelter/

Roof 1 Prefab

33.052356, -114.827464 Average

Floor panels are damaged, no major structural issues observed 5-10 years

Shelter 1

Access

Single

Door

33.052356, -114.827464 Good

Located on north side of shelter, no major issues observed 10+ years

HVAC Unit Through

Wall

33.052356, -114.827464 Good

Bard manufacturer tag, appears to be working properly 10+ years

Shelter 2 Molded

Plastic

33.052289, -114.827400 Good

Vertex Plastics, Inc. manufacturer tag, appears to be in good condition, no major issues observed

10+ years

Shelter 2

Access

Single

Door

33.052289, -114.827400 Good

Located on east side of shelter, no major issues observed 10+ years

A/C Unit Through

Wall

33.052289, -114.827400 Good

Frigidaire manufacturer tag, appears to be working properly 10+ years

Power

Supply 1

Power

Meter

33.052411, -114.827553 Good

Located on utility pole, marked “General

Electric”, appears to be working properly 10+ years

Power

Supply 2

Power

Meter

33.052411, -114.827553 Good

Located on utility pole, marked “Itron”, appears to be working properly 10+ years

Power

Supply 3 Generator

33.052258, -114.827392 Good

Hydrogen fuel cell, marked “Reli On”, appears to be working properly 10+ years

Power

Supply 4 Generator

33.052336, -114.827525 Good

Marked “Kohler Power System”, appears to be working properly 10+ years

Power

Supply 5

Solar

Panel

33.052303, -114.827522 Good Appears to be working properly 10+ years

Gas

Source Fuel Tank

33.052350, -114.827456 Good No major issues visible 10+ years

Cellular

Receivers

- - Good

Shelters house various units associated with communication equipment, no major issues of note

10+ years

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Capital Expenditure Table

A cost estimate of $69,650 was provided to cover repairs and additional inspections as recommended in the

Maintenance and Condition Assessment Report and the Structural Analysis Report. The recommended repair schedule ranges from 6 months to 5 years. Also note that this estimate does not include any foundation reinforcements that may be required. TEP cannot say with certainty that modifying the existing tower would be more cost effective than a replacement without completing a Structural Modification Design Analysis. Refer to the

Capital Expenditure Table for details. For itemized repairs, refer to the Capital Expenditure Table for details. TEP estimated a ROM cost for full tower replacement would range from approximately $160,000 for a 100-ft self supporting tower to $250,000 for a 200-ft self supporting tower. These estimates do not include pricing for site specific costs related to zoning, permitting, environmental studies, etc.

Steel and Appurtenance Mapping

The original design criteria were unavailable for review. A Steel and Appurtenance Mapping was performed in order to obtain the necessary tower and appurtenance loading information needed to conduct the Structural Analysis for this site. The antennas recorded during our Steel and Appurtenance Mapping are depicted in the table below. TEP denoted the owner of the equipment under the “Owner/Tenant” column based on information available on site.

Refer to the Steel and Appurtenance Mapping Report for additional detail.

Elevation

(ft) Qty Antenna Model

Mount

Type

Owner/

Tenant

168.0 3 2.8”Ø x 20’ Tapered Omni (3) Standoff CBP

145.0 1 CWT RuralConnect Direct CBP

147.0 1 RFI BA40-41-DIN Sidearm CBP

127.0 1 RFI BA40-41-DIN Sidearm CBP

111.0 2 2.8”Ø x 20’ Tapered Omni (2) Standoff CBP

81.7 1 Andrew DB222-A Sidearm Fish & Game

77.0 1 Andrew HP6-71W-P3A/C Pipe CBP

63.5 1 Andrew PL10-71GE-1 Pipe CBP

63.3 1 Andrew PL10-71GE-1 Pipe CBP

51.0 1 Andrew HP6-71W-P3A/C Pipe CBP

51.0 1 Andrew HPX8-71W-P1A Pipe CBP

51.0 1 Mark P-9LA96GN Pipe CBP

41.0 1 6-Element Yagi Sidearm CBP

41.0 1 Kathrein 94150-003 Pipe CBP

30.5 1 Radiowaves G6-2.4 Pipe CBP

18.5 1 Andrew HPX8-71W-P1A Pipe CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Structural Analysis

The Structural Analysis report outlines overstresses in the tower legs from 20’ to 40’ elevations and diagonal bracing from 0’ to 80’ elevations. TEP believes that the majority of the overstresses can be attributed to the more stringent loading and analysis criteria as required by the latest ANSI/TIA-222-G-2-2009 Standard, as compared to previous versions of the TIA Standard for which the tower was originally designed. Based on our analysis we have determined the tower stress level for each controlling component, under the following load case, to be:

LC1: Existing Equipment Insufficient Capacity Note: See Table 1 for the existing loading

Thank you for the opportunity to provide this service for you. If you have any questions or comments, please contact our office.

Component % Capacity

Leg (T7) 131.7

Diagonal (T6) >200.0

Top Girt (T1) 3.5

Bolt Checks 187.8

Anchor Rods 79.7

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

MASTER TABLE OF CONTENTS

���� MAINTENANCE AND CONDITION ASSESSMENT

���� CAPITAL EXPENDITURE TABLE

���� ANNEX A: STEEL AND APPURTENANCE MAPPING

���� ANNEX B: STRUCTURAL ANALYSIS

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

MAINTENANCE AND CONDITION ASSESSMENT

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Date: September 15, 2016

HGA Architects and Engineers 326 Tryon Road

420 5th Street North, Suite 100 Raleigh, NC 27603

Minneapolis, MN 55401 (919) 661-6351

(612) 758-4502 StructuresReview@tepgroup.net

Subject: Maintenance and Condition Assessment Report

Tower Designation: Site Number: CA9998

Site Name: Black Mountain

Engineering Firm Designation: TEP Project Number: 69451_85599

Site Data: Black Mountain Road, Palo Verde, Imperial County, CA 92266

Lat., Long.: 33.052319, -114.827463

(N 33° 03' 08.35”, W 114° 49' 38.87”)

160 Foot ± – Self Supporting Tower

Dear Mr. Fiskum, Tower Engineering Professionals (TEP) completed a periodic inspection for the above referenced site. The onsite investigation was performed by Bryan Gilliam, C.W.I. and Cameron Torgent, E.I. of TEP during the July 12, 2016 site visit.

The inspection was in accordance with the ANSI/TIA-222-G-2005, Annex J: Maintenance and Condition Assessment

(Normative), including all addendums (addendums TIA-222-G-1 2007 and TIA 222-G-2 2009); the checklist can be found on pages 3 thru 8 of this report.

Observations and recommendations are listed herein. The inspection included observation of the tower components and CBP owned assets. For the purpose of this inspection, the tower legs were named by letter according to the magnetic azimuth defined by a line from the center of tower to the leg. “A” leg is the leg closest to magnetic north, followed clockwise by “B” and “C.”

Thank you for the opportunity to provide this service for you. If you have any questions or comments, please contact our office.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Self Supporting Tower Maintenance and Condition Assessment Report September 15, 2016

TEP Project Number 69451_85599 CA9998 - Black Mountain

TABLE OF CONTENTS

1) ANSI/TIA-222-G-MAINTENANCE AND CONDITION ASSESSMENT

2) SUMMARY

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

ANSI/TIA-222-G MAINTENANCE AND CONDITION ASSESSMENT

A. STRUCTURE CONDITION

A.1. Damaged members (legs and bracing)

Okay Possible Improvement Needs Repair Not Applicable

Notes: Surface corrosion observed on leg member at 1-ft on B-leg. Bent top girt member observed at 160-ft on the CA face. Surface corrosion observed on C-leg at base. See executive summary for details and recommendations.

A.2. Loose members

Okay Possible Improvement Needs Repair Not Applicable

Notes:

A.3. Missing members

Okay Possible Improvement Needs Repair Not Applicable

Notes:

A.4. Climbing facilities, platforms, catwalks – all secure

Okay Possible Improvement Needs Repair Not Applicable

Notes: Missing step peg at 30.5-ft at B-leg. (2) Missing step pegs at 29.25-ft on C-leg. (6) Missing step pegs at 60-ft. Missing step peg at

61-ft on A-leg. See executive summary for details and recommendations.

A.5. Loose and/or missing bolts and/or nut locking devices

Okay Possible Improvement Needs Repair Not Applicable

Notes: Missing nut locking devices on C-leg at 120-ft. Undersized diagonal bolt at 40-ft on B-leg. See executive summary for details and recommendations.

A.6. Visible cracks in welded connections

Notes:

B. FINISH

B.1. Paint and/or galvanizing condition

Notes:

B.2. Rust and/or corrosion condition including mounts and accessories

Okay Possible Improvement Needs Repair Not Applicable

Notes:

B.3. FAA or ICAO color marking conditions

Okay Possible Improvement Needs Repair Not Applicable

Notes:

B.4. Water collection in members (to be remedied, e.g., unplug drain holes, etc.)

Okay Possible Improvement Needs Repair Not Applicable

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

C. LIGHTING

C.1. Conduit, junction boxes, and fasteners (weather tight and secure)

Notes:

C.2. Drains and vents openings (unobstructed)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

C.3. Wiring Condition

Okay Possible Improvement Needs Repair Not Applicable

Notes:

C.4. Light lenses

Okay Possible Improvement Needs Repair Not Applicable

Notes:

C.5. Bulb condition

Okay Possible Improvement Needs Repair Not Applicable

Notes: Top of tower beacon on the A-leg at 160-ft is malfunctioning. See executive summary for details and recommendations.

C.6.a. Controllers functioning (Flasher)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

C.6.b. Controllers functioning (Photo control)

Okay Possible Improvement Needs Repair Not Applicable

Notes: Top of tower beacon on the A-leg at 160-ft is malfunctioning.

C.6.c. Controllers functioning (Alarms)

D. GROUNDING

D.1. Connections

Notes:

D.2. Corrosion

Okay Possible Improvement Needs Repair Not Applicable

Notes:

D.3. Lightning protection (secured to structure)

Okay Possible Improvement Needs Repair Not Applicable

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

E. ANTENNAS AND LINES

E.1. Antenna condition

Notes:

E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)

Okay Possible Improvement Needs Repair Not Applicable

Notes: Unused antenna mount on A leg at 25-ft. Unused antenna mount on CA face at 26-ft. Unused antenna mounts on BC face at

87-ft See executive summary for details and recommendations.

E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)

Okay Possible Improvement Needs Repair Not Applicable

Notes: Small areas of surface corrosion observed intermittently throughout waveguide on AB-face. See executive summary for details and recommendations.

E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)

Okay Possible Improvement Needs Repair Not Applicable

Notes: Missing snap-in observed at 50-ft on CA face. See executive summary for details and recommendations.

E.5. Secured to structure

F. OTHER APPURTENANCES (WALKWAYS, PLATFORMS, SENSORS, FLOODLIGHTS, ETC.)

F.1. Condition

Notes:

F.2. Secured to structure

G. INSULATOR CONDITION

G.1. Cracking and chipping

Notes:

G.2. Cleanliness of insulators

Okay Possible Improvement Needs Repair Not Applicable

Notes:

G.3. Spark gaps set properly

Okay Possible Improvement Needs Repair Not Applicable

Notes:

G.4. Isolation transformer condition

Okay Possible Improvement Needs Repair Not Applicable

Notes:

G.5. Bolts and connection secure

Okay Possible Improvement Needs Repair Not Applicable

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

H. GUYS

H.1. Strand condition (corrosion, breaks, nicks, kinks, etc.)

Notes:

H.2.a. Guy Hardware Conditions (Turnbuckles or equivalent (secure and safety properly applied)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.b. Guy Hardware Conditions (Cable thimbles properly in place (if required))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.c. Guy Hardware Conditions (Service sleeves properly in place (if required))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.d.i. Guy Hardware Conditions (Cable connectors (end fittings) (Cable clamps applied properly and bolts tight))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.d.ii. Guy Hardware Conditions (Cable connectors (end fittings) (Wire serving properly applied))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.d.iii. Guy Hardware Conditions (Cable connectors (end fittings) (No signs of slippage or damaged strands))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.d.iv. Guy Hardware Conditions (Cable connectors (Preformed wraps – properly applied, fully wrapped, & sleeve in place))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.d.v. Guy Hardware Conditions (Cable connectors (end fittings) (Poured sockets secure and showing no separation))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.2.d.vi. Guy Hardware Conditions (Cable connectors (Shackles, bolts, pins, and cotter pins secure and in good condition))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.3. Guy tensions

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.4. Measure guy tensions

Okay Possible Improvement Needs Repair Not Applicable

Notes:

H.5. Record temperature, wind speed and wind direction

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

I. CONCRETE FOUNDATIONS

I.1.a. Ground condition (Settlement, movement or earth cracks)

Notes:

I.1.b. Ground condition (Erosion)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.1.c. Ground condition (Site condition (standing water, drainage, trees, etc.))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.2.a. Anchorage condition (Nuts and/or nut locking device (tightened))

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.2.b. Anchorage condition (Grout condition)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.2.c. Anchorage condition (Anchorages and/or anchor rod condition)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.3.a. Concrete condition (Cracking, spalling, or splitting)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.3.b. Concrete condition (Chipped or broken concrete)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.3.c. Concrete condition (Honeycombing)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

I.3.d. Concrete condition (Low spots to collect moisture)

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

J. GUYED MAST ANCHORS

J.1. Settlement, movement or earth cracks

Notes:

J.2. Backfill heaped over concrete for water shedding

Okay Possible Improvement Needs Repair Not Applicable

Notes:

J.3. Anchor rod condition below earth (Maintain required structural capacity of anchor during exploration.)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

J.4. Corrosion control measures (galvanizing, coating, concrete encasement, cathodic protection systems, etc.)

Okay Possible Improvement Needs Repair Not Applicable

Notes:

J.5. Anchor heads clear of earth

K. TOWER ALIGNMENT

K.1. Tower Plumb and Twist

Notes: Tower twist and plumb was not measured as a part of this scope of work.

L. NON-TIA RELATED ITEMS

L.1. Equipment Shelter

Notes:

L.2. Security

Okay Possible Improvement Needs Repair Not Applicable

Notes:

L.3. Other Equipment

Okay Possible Improvement Needs Repair Not Applicable

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

SUMMARY

Photograph Observations and Recommendations

Observation:

Surface corrosion observed on leg member at 1-ft on B-leg.

Recommendation:

Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Surface corrosion observed on C-leg at base.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

Bent top girt member observed at 160-ft on the CA face.

Replace damaged member.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

A.4. Climbing facilities, platforms, catwalks – all secure

Missing step peg at 30.5-ft at B-leg.

Replace with a new 5/8” dia. 7” long step peg.

(2) Missing step pegs at 29.25-ft on C-leg.

Replace with new 5/8” dia. 7” long step pegs.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

(6) Missing step pegs at 60-ft.

Replace with new 5/8” dia. 7” long step pegs.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

A.5. Loose and/or missing bolts and/or nut locking devices

Missing nut locking devices on C-leg at 120-ft.

Install nut locking devices. If necessary, re-install longer bolts to accommodate the use of nut locking devices.

Tighten all nuts per the AISC “turn of the nut” method.

A.5. Loose and/or missing bolts and/or nut locking devices

Undersized diagonal bolt at 40-ft on B-leg.

Install a new A325X 5/8” dia. diagonal bolt. Tighten nut per the AISC “turn of the nut” method. Install nut locking device on new bolt.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

C.5. Bulb condition

Top of tower beacon on the A-leg at 160-ft is malfunctioning.

Repair or replace beacon.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)

Unused antenna mount on A leg at 25-ft.

Removing the unused antenna mount will improve the overall structural capacity of the tower.

Unused antenna mount on CA face at 26-ft.

Unused antenna mount on BC face at 87-ft.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

E.3 Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)

Small areas of surface corrosion observed intermittently throughout waveguide on AB-face.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)

Missing snap-in observed at 50-ft on CA face.

Reattach coax to tower.

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

CAPITAL EXPENDITURE TABLE

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

ANSI/TIA-222-G: CAPITAL EXPENDITURE TABLE

Job Name: CA9998 - Black Mountain

TEP Number: 69451_85599

A. STRUCTURAL CONDITION

Issue: Repair/Modification: Repair Schedule:

A.1. Damaged members (legs and bracing)

a. Surface corrosion observed on leg member at 1-ft on B-leg. i. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.

0-1 year $150

b. Surface corrosion observed on C-leg at base. ii. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing compound or approved equivalent.

0-1 year $100

c. Bent top girt member observed at 160-ft on the CA face. iii. Replace damaged member. 0-6 months $1,500

d. The following members were overstressed in the structural analysis:

iv. Complete repairs as specified in Structural Design

Drawings.

0-6 months $60,000

● Tower Legs from 20'-40'

● Tower Diagonals from 0'-80'

Sub Total: $61,750

A.4. Climbing facilities, platforms, catwalks – all secure

a. Missing step peg at 30.5-ft at B-leg. i. Replace with a new 5/8” dia. 7” long step peg. 0-1 year $50

b. (2) Missing step pegs at 29.25-ft on C-leg. ii. Replace with new 5/8” dia. 7” long step pegs. 0-1 year $75

c. (6) Missing step pegs at 60-ft. iii. Replace with new 5/8” dia. 7” long step pegs. 0-1 year $125

d. Missing step pegs at 61-ft on A-leg. iv. Replace with a new 5/8” dia. 7” long step peg. 0-1 year $50

Sub Total: $300

A.5. Loose and/or missing bolts and/or nut locking devices

a. Missing nut locking devices on C-leg at 120-ft. i. Install nut locking devices. If necessary, re-install longer bolts to accommodate the use of nut locking devices. Tighten all nuts per the AISC “turn of the nut” method.

0-6 months $150

b. Undersized diagonal bolt at 40-ft on B-leg. ii. Install a new A325X 5/8” dia. diagonal bolt. Tighten nut per the AISC “turn of the nut” method. Install nut locking devices on all new bolts.

0-6 months $350

Sub Total: $500

Total: $62,550

B. FINISH

NO DEFICIENCIES WERE IDENTIFIED

C. LIGHTING

Issue: Repair/Modification: Repair Schedule:

C.5. Bulb condition

a. Top of tower beacon on the A-leg at 160-ft is malfunctioning. i. Repair or replace beacon. 0-1 year $1,500

Sub Total: $1,500

Total: $1,500

D. GROUNDING

NO DEFICIENCIES WERE IDENTIFIED

*Items that don't require attention were omitted from this list of itemized modification costs. For a full itemized list of everything that was assessed during our site visit please reference the Maintenance and Condition Assessment.

Fee:

Fee:

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

E. ANTENNAS AND LINES

Issue: Repair/Modification: Repair Schedule:

E.2. Mount and/or ice shield condition (bent, loose, and/or missing members)

a. Unused antenna mount on A leg at 25-ft. i. Removing the unused antenna mount will improve the overall structural capacity of the tower.

0-5 years $150

b. Unused antenna mount on CA face at 26-ft. ii. Removing the unused antenna mount will improve the overall structural capacity of the tower.

0-5 years $250

c. Unused antenna mount on BC face at 87-ft. iii. Removing the unused antenna mount will improve the overall structural capacity of the tower.

0-5 years $250

Sub Total: $650

E.3. Feed line condition (flanges, seals, dents, jacket damage, grounding, etc.)

a. Small areas of surface corrosion observed intermittently throughout waveguide on AB-face.

i. Clean areas of corrosion down to sound metal and coat with two brush coats of ZRC cold galvanizing

0-1 year $400

Sub Total: $400

E.4. Hanger condition (snap-ins, bolt on, kellum grips, etc.)

a. Missing snap-in observed at 50-ft on CA face. i. Reattach coax to tower. 0-1 year $50

Sub Total: $50

Total: $1,100

F. OTHER APPURTENANCES (WALKWAYS, PLATFORMS, SENSORS, FLOODLIGHTS, ETC.)

NO DEFICIENCIES WERE IDENTIFIED

G. INSULATOR CONDITION

NO DEFICIENCIES WERE IDENTIFIED

H. GUYS

NO DEFICIENCIES WERE IDENTIFIED

I. CONCRETE FOUNDATIONS

NO DEFICIENCIES WERE IDENTIFIED

J. GUYED MAST ANCHORS

NO DEFICIENCIES WERE IDENTIFIED

K. TOWER ALIGNMENT

NO DEFICIENCIES WERE IDENTIFIED

L. NON-TIA ISSUES

NO DEFICIENCIES WERE IDENTIFIED

OTHER CONSTRUCTION COSTS

Item:

a. Permits / Application Fees $1,000

b. Post Modification Inspection Report $2,000

c. Mobilization Costs $1,500

Sub Total: $4,500

Total: $4,500

GRAND TOTAL: $69,650

Fee:

Fee:

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

ANNEX A:

STEEL AND APPURTENANCE MAPPING

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Page Title Initials Page # (s) Notes Checklist & Notes

Tower Elevation Tower Section Elevation Transmission Cables

Antenna and Mount Sketch Photos

CJT

6-13 14-15 16-37 38-41

CHECKLIST

Latitude: Longitude:

Ground Elevation:

Site Address:

Tower ID Plate:

Existing Carriers/Site #:

Gate Combo:

Telephone Company:

Pedestal # and Location:

Power Company:

Meter # and Owner:

33.052319° (N 33° 03' 08.35")

2077-FT (VIA GOOGLE EARTH)

BLACK MOUNTAIN ROAD, PALO VERDE, CA 92266 (IMPERIAL COUNTY)

NONE OBSERVED

NONE OBSERVED

NONE OBSERVED

IMPERIAL IRRIGATION DISTRICT

78 603 679 / CBP

CBP / CA9998

N/A

-114.827463° (W 114° 49' 38.87")

Crew Leader:

Crew Member: CAMERON J. TORGENT, E.I.

Abbreviations: AGL: Above Ground Level B.C.: Bolt Circle BP: Bent Plate C-C: Center to Center C: Channel CNR: Could Not Record EW: Elliptical Waveguide FH: Foam Heliax

HCL: Hard Copper Line HSS: Hollow Structural Section L: Angle 2L: Double Angle MC: Metal Conduit M.E.: Minimum Edge MOD: Modification PL: Plate

RC: Rigid Conduit S.B.: Stitch Bolts Schl: Schifflerized Angle SM: Smooth Heliax SP: Spacing SR: Solid Rod TH: Thickness Tri: Triangular

BRYAN J. GILLIAM, C.W.I.

NOTES

FCC#: N/A

Special Access Issues (Key Entry, Hidden/Unmarked Access, FM/TV on tower): CONTACT RICHARD KNIGGE

Compound Detail 2

(928) 341-6622 OR (520) 909-7602

Ladder 3

CJT

CJT

CJT

CJT

CJT

CJT

CJT

CJT

Waveguide

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

COMPOUND DETAIL

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Access Road Compound View CBP Equipment Shelter

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

LADDER

Climbing Ladder #1 Sketch

Description Ladder

# Height Width Step Rail (type & size) Rung (type & size) Safety (type & size)

Pegs Pegs Pegs

14" 7" 7" 7"

15" 15" 15" 15"

PL11

2"x14"

A LEG

B LEG

C LEG

8"Ø

8"Ø

8"Ø

8"Ø

8"Ø32"-163'1

-20'-80' -20'-80' -20'-160'

Climbing Ladder #1 Photo

Climbing Ladder #2 Photo

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Description # Height Width Step Rail (type & size) Rung (type & size) Holes (size & spacing)

Waveguide Waveguide

WAVEGUIDE

0'-161'± 311 2" 48" L11

2"x11 2"x18" PL11

2"x38" (29) 14"Ø1 2 21'-62'± 121

2" 48" L2"x2"x14" L2"x2"x14"

Waveguide Ladder #1 Sketch Waveguide Ladder #1 Photo

Waveguide Ladder #2 Photo

(6) 716"Ø

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER ELEVATION

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

BASE PLATE PHOTOSECTION _______________1 (0' - 20') PHOTO

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________23'-0"

21'-15 16"

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P5.5"Øx0.377"TH* L4"x4"x14"TH

(6) 1"Ø PL91

2"x91

2"x11

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

1"

*LEG MOD (0'-20'): L6"x6"x5

16"TH W/

ONE CONTINUOUS WELD TO PIPE

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________2 (20' - 40')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________21'-15

16" 19'-29

16"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P5.5"Øx0.265"TH L31

2"x31 2"x14"TH

(4) 1"Ø PL91

2"x91

2"x11

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

1"

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________3 (40' - 60')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________19'-29

16" 17'-37

8"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P5.5"Øx0.386"TH L3"x3"x14"TH

(4) 1"Ø PL91

2"x91

2"x11

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________4 (60' - 80')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________17'-37

8" 15'-51

8"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P5.5"Øx0.284"TH L3"x3"x14"TH

(4) 1"Ø PL91

2"x91

2"x11

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________5 (80' - 100')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________15'-51

8" 13'-67

16"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P4.5"Øx0.345"TH L21

2"x21 2"x14"TH

(4) 1"Ø PL91

2"x91

2"x11

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________6 (100' - 120')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________13'-67

16" 11'-711

16"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P3.5"Øx0.344"TH L21

2"x21 2"x14"TH

(4) 78"Ø PL7"x7"x1"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________7 (120' - 140')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________11'-711

16" 9'-9"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P2.9"Øx0.314"TH L21

2"x21 2"x14"TH

(4) 34"Ø PL6"x6"x3

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

1"

GIRT L21

2"x21

2"x316"TH 1

4"TH--(1) 58"Ø 1"

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TOWER MAPPING

Site Name

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TOWER SECTION ELEVATION

SECTION __________________8 (140' - 160')

MEMBER SIZES

Face Width at Top ___________ Face Width at Bottom_________9'-9"

9'-9"

PHOTO PHOTO

Member

LEG

DIAG.

Size Bolts Gussets/Flange

P2.9"Øx0.205"TH L2"x2"x14"TH

(4) 58"Ø PL5"x5"x3

4"TH

4"TH

Stitch Bolt

(1) 58"Ø(1) 58"Ø

Min. Edge

1"

GIRT L21

2"x21

2"x316"TH 1

4"TH--(1) 58"Ø 1"

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

TRANSMISSION CABLES

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Coax # Type/Style Start Height End Height Antenna Carrier Notes

CBP2 77'-0"

CBP

41'-0" 4 CBP3

EW 77 9'-0" 51'-0" 7 CBP

EW 77 9'-0"

FH 12 9'-0"

CBP5 121'-6"

CBP

141'-6" 15 CBP6

FH 12 9'-0" 41'-0" 3 CBP

FH 78 9'-0"

FH 78 9'-0"

CBP7 145'-0" 16

51'-0" 6 CBP8

SM 516"Ø 9'-0"

EW 77 9'-0"

CBP10 157'-6"

CBP

157'-6" 18 CBP11

EW 77 9'-0" 18'-6" 1 CBP

FH 78 9'-0"

FH 78 9'-0"

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

TRANSMISSION CABLES (CONTINUED)

Coax # Type/Style Start Height End Height Antenna Carrier Notes

CBP13 100'-6"

CBP

51'-0" 5 CBP14

FH 78 9'-0" 100'-6" 12 CBP

FH 78 9'-0"

FH 78 9'-0"

CBP16 157'-6"

FISH & GAME

161'-0" - CBP17

FH 12 9'-0" 81'-8" 11

FH 78 9'-0"

1"Ø M.C. 9'-0"

CBP18 63'-4" 8

63'-6" 9 CBP19

EW 77 21'-0"

EW 77 21'-0"

20 CBPFH 12 21'-0" 30'-6" 2 CBP

CONDUIT FOR LIGHTS

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Photo

Mount Elevation LegAntenna # 1 18'-6" B

Mount Type Azimuth

PIPE 140°

Antenna Manufacturer Antenna Model #

ANDREW HPX8-71W-P1A

TMA (#) / Model # (Coax Quantity) Size

N/A (1) EW 77

Antenna Elevation 18'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation

Mount Elevation LegAntenna #

- 25'-0" A

Mount Type Azimuth

DIRECT N/A

Antenna Manufacturer Description

- P4.5"Øx6.5'

Offset (Coax Quantity) Size 11" N/A

Antenna Elevation

Carrier______________CBP

Photo

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation

Mount Elevation FaceAntenna #

- 26'-0" CA

Mount Type Azimuth

DIRECT N/A

Antenna Manufacturer Description

- HSS 6"x6"x20'

TMA (#) / Model # (Coax Quantity) Size N/A N/A

Antenna Elevation

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Photo

Mount Elevation LegAntenna # 2 30'-6" B

Mount Type Azimuth

PIPE 170°

Antenna Manufacturer Antenna Model #

RADIOWAVES G6-2.4

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 12

Antenna Elevation 30'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 3 41'-0" B

Mount Type Azimuth

PIPE 170°

Antenna Manufacturer Antenna Model #

KATHREIN 94150-003

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 12

Antenna Elevation 41'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 4 41'-0" C

Mount Type Azimuth

SIDEARM 180°

Antenna Manufacturer Antenna Model #

UNKNOWN 6 ELEMENT YAGI

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 12

Antenna Elevation 41'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 5 51'-0" A

Mount Type Azimuth

SIDEARM 0°

Antenna Manufacturer Antenna Model #

MARK ANTENNAS P-9LA96GN

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 78

Antenna Elevation 51'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 6 51'-0" B

Mount Type Azimuth

PIPE 150°

Antenna Manufacturer Antenna Model #

ANDREW HPX8-71W-P1A

TMA (#) / Model # (Coax Quantity) Size

N/A (1) EW 77

Antenna Elevation 51'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 7 51'-0" C

Mount Type Azimuth

PIPE 240°

Antenna Manufacturer Antenna Model #

ANDREW HP6-71W-P3A/C

TMA (#) / Model # (Coax Quantity) Size

N/A (1) EW 77

Antenna Elevation 51'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 8 63'-4" A

Mount Type Azimuth

PIPE 0°

Antenna Manufacturer Antenna Model #

ANDREW PL10-71GE-1

TMA (#) / Model # (Coax Quantity) Size

N/A (1) EW 77

Antenna Elevation 63'-4"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 9 63'-6" B

Mount Type Azimuth

PIPE 135°

Antenna Manufacturer Antenna Model #

ANDREW PL10-71GE-1

TMA (#) / Model # (Coax Quantity) Size

N/A (1) EW 77

Antenna Elevation 63'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 10 77'-0" C

Mount Type Azimuth

PIPE 240°

Antenna Manufacturer Antenna Model #

ANDREW D6F-5-GR

TMA (#) / Model # (Coax Quantity) Size

N/A (1) EW 77

Antenna Elevation 77'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 11 81'-8" B

Mount Type Azimuth

SIDEARM N/A

Antenna Manufacturer Antenna Model #

ANDREW DB222-A

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 12

Antenna Elevation 81'-8"

Carrier______________FISH & GAME

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation

Mount Elevation FaceAntenna #

- 87'-0" BC

Mount Type Azimuth

DIRECT N/A

Antenna Manufacturer Description

- HSS 31

2"x31 2"x131

2' TMA (#) / Model # (Coax Quantity) Size

N/A N/A

Antenna Elevation

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 12 102'-0" A

Mount Type Azimuth

STANDOFF N/A

Antenna Manufacturer Antenna Model # UNKNOWN 2.8"Øx20' TAPERED OMNI

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 78

Antenna Elevation 100'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 13 102'-0" B

Mount Type Azimuth

STANDOFF N/A

Antenna Manufacturer Antenna Model # UNKNOWN 2.8"Øx20' TAPERED OMNI

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 78

Antenna Elevation 100'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 14 121'-6" B

Mount Type Azimuth

SIDEARM N/A

Antenna Manufacturer Antenna Model #

RFI BA40-41-DIN

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 78

Antenna Elevation 121'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 15 141'-6" B

Mount Type Azimuth

SIDEARM N/A

Antenna Manufacturer Antenna Model #

RFI BA40-41-DIN

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 78

Antenna Elevation 141'-6"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 16 - A

Mount Type Azimuth

DIRECT 330°

Antenna Manufacturer Antenna Model # RURAL CONNECT 9"x11"x51

2" TMA (#) / Model # (Coax Quantity) Size

N/A (1) SM 516"Ø

Antenna Elevation 145'-0"

Carrier______________CBP

PROPERTY OF THE UNITED STATES GOVERNMENT- FOR OFFICIAL USE ONLY- DO NOT REMOVE THIS NOTICE- PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED

TEP #

Client # Date Page of

BLACK MOUNTAIN

69451_85599

CA9998

SEPTEMBER 15, 2016

ANTENNA AND MOUNT SKETCH

326 Tryon Road, Raleigh, NC 27603 o) 919.661.6351 f) 919.661.6350 www.tepgroup.net

Side Elevation Plan View

Mount Elevation LegAntenna # 17 157'-6" A

Mount Type Azimuth

STANDOFF N/A

Antenna Manufacturer Antenna Model # UNKNOWN 2.8"Øx20' TAPERED OMNI

TMA (#) / Model # (Coax Quantity) Size

N/A (1) FH 78

Antenna Elevation 157'-6"

Carrier______________CBP