This document is a PLM (Polarized Light Microscopy) Bulk Asbestos Report for Atlantic Testing Laboratories, analyzing samples from the St. Lawrence Seaway's Eisenhower/Snell Locks project in Massena, NY. The report, dated January 30, 2014, details asbestos analysis for samples collected on January 28, 2014, specifically from the Eisenhower Vehicle Tunnel's Utility Tunnel gray cementitious 4-inch conduit. Key findings include one sample (Sample #11) containing 11% total asbestos: 2.3% Crocidolite and 8.8% Chrysotile, with 89% non-fibrous material. Another sample (Sample #12) was marked as NA/PS (not analyzed/positive stop). The analysis was conducted by AmeriSci (Job #214013704) using EPA and New York State approved methodologies, with David W. Roderick and Aleksandr Barengolts performing the analysis.

View the file

Other files

File Type Posted
6923G525Q0667 QA.pdf PDF
6923G525Q0667A00001.pdf PDF
Attachment B_Pricing Sheet.xlsx XLSX spreadsheet
RFQ 6923G525Q0667.pdf PDF
Attachment D_Reference Drawings.pdf PDF
Attachment C_Service Contract Act WD 2015-4169.pdf PDF
Attachment A_PWS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Please Reply To:

AmeriSci New York

117 EAST 30TH ST.

AMER1Sc1 NEW YORK, NY 10016

TEL: (212) 679-8600 • FAX: (212) 679-3114

FACSIMILE TELECOPY TRANSMISSION

To: Derek Converse From: Aleksandr Barengolts

214013704 Atlantic Testing Laboratories, Limited

Fax#: (315)714-2272

AmeriSci Job #:

Subject: ELAP-PLM/TEM 24 hour Results

Email:

Date:

Time:

Comments:

Thursday, January 30, 2014

09:05:56

Client Project: CT6549; St. Lawrence Seaway;

Eisenhower I Snell Locks, Massena, NY

Number of Pages:

(including cover sheet)

CONFIDENTIALITY NOTICE: Unless othetwise indicated, the information contained in this communication is confidential information intended for use of the individual named above. If the reader of this communication is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is prohibited. If you have received this communication in error, please immediately notify the sender by telephone and return the original message to the above address via the US Postal Service at our expense. Preliminary data reported here wll be verified before final report is issued. Samples are disposed of in 60 days or unless otheiwise instructed by the protocol or special instructions in writing. Thank you.

Certified Analysis Service 24 Hours A Day • 7 Days A Week Competitive Prices visit our web site - www.ameriscl.com

Boston• Los Angeles• New York• Richmond

AmeriSci Job#: 214013704

Client Name: Atlantic Testing Laboratories, Limited

PLM Bulk Asbestos Report CT6549; St. Lawrence Seaway; Eisenhower / Snell Locks, Massena, NY

Client No. / HGA Lab No. Asbestos Present

CT6549AB06A012814 214013704-11 Yes

06 Location: Eisenhower Vehicle Tunnel - Utility Tunnel / Gray Cementitious 4-lnch Conduit

Analyst Description: Grey, Homogeneous, Fibrous, Cementitious, Bulk Material

Asbestos Types: Crocidolite 2.3 %, Chrysotile 8.8 %

Other Material: Non-fibrous 89 %

See Reporting notes on last page

Total% Asbestos

11 %

(EPA 400 PC)

by David W. Roderick on 01/30/14

AmeriSci Job #: 214013704

PLM Bulk Asbestos Report CT6549; St. Lawrence Seaway; Eisenhower / Snell Locks, Massena, NY

Client No. I HGA Lab No. Asbestos Present

CT6549AB068012814 214013704-12

06 Location: Eisenhower Vehicle Tunnel - Utility Tunnel / Gray Cementitious 4-lnch Conduit

Analyst Description: Bulk Material

Asbestos Types:

Other Material:

Total % Asbestos

NA/PS

Reporting Notes: � Analyzed by: David W. Roderick ;& �,d *NAD/NSD =no asbestos detectet(NA =not analyzed; NNPS=not analyzed/positive stop; PLM Bulk Asbestos Analysis by EPA 600/M4-82-020 per 40 CFR 763 (NVLAP Lab Code 200546-0), ELAP PLM Method 198.1 for NY friable samples, which includes the identification and quantitation of vermiculite or 198.6 for NOB samples or EPA 400 pt ct by EPA 600/M4-82-020 (NY ELAP Lab ID11480); Note:PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. NAD or Trace results by PLM are inconclusive, TEM is currently the only method that can be used to determine if this material can be considered or treated as non asbestos-containing in NY State (also see EPA Advisory for floor tile, FR 59, 146,38970,8/1/94) National Institute of Standards and Technology Accreditation requirements mandate that this repor1 must not be reproduced except In full without the approval of the lab.This PLM report relates ONLY to the Items tested. AIHA Lab# 102843, RI Cert#AAL-094, CT Cert#PH-0186, Mass Cert#AA000054.

Reviewed By: ______________ _ _ ____ END OF REPORT ___ _

AmeriSci Job#: 214013704

AmeriSci Sample # Client Sample#

HG

Area

Table I

Summary of Bulk Asbestos Analysis Results CT6549; St. Lawrence Seaway; Eisenhower / Snell Locks, Massena, NY

Sample Weight (gram)

Heat Sensitive

Organic%

Acid Soluble

Inorganic%

Insoluble Non-Asbestos

Inorganic% '""'Asbestos % by

PLM/DS

'""'Asbestos % by

TEM

Analyzed by: Aleksandr Barengolts lJ

; Date Analyzed 1/30/2014 **Quantitative Analysis (Semi/Full); Bulk Asbestos� sis - PLM by EPA 600/M4-82-020 per 40 CFR or ELAP 198.1 for New York friable samples or ELAP 198.6 for New York NOB samples; TEM (Semi/Full) by EPA 600/R-93/116 (not covered by NVLAP Bulk accreditation) or ELAP 198.4; for New York samples; NAO = no asbestos detected during a quantitative analysis; NA = not analyzed; Trace = <1 %; Quantitation for beginning weights of <0.1 grams should be considered as qualitative only; Qualitative Analysis: Asbestos analysis results of "Present" or "NVA = No Visible Asbestos" represents results for Qualitative PLM or TEM Analysis only (no accreditation coverage available from any regulatory agency for qualitative analyses): AIHA Lab# 102843, NVLAP Lab Code 200546-0, NYSDOH ELAP Lab 10#11480.

Warning Note: PLM limitation, only TEM will resolve fibers <0.25 micrometers in diameter. TEM bulk analysis is representative of the fine grained matrix material and may not be representative of non-uniformly dispersed debris for which PLM evaluation is recommended (i.e. soils and other heterogenous materials).

Reviewed By: __________________ _