SOW Bowditch Hall Gun Range- REVISED.pdf
PDF 3 MB Posted
- Solicitation number
- 6923G226Q000024
About this file
This is a Statement of Work (SOW) for a one-time comprehensive cleaning and remediation project of the Bowditch Hall indoor gun range at the United States Merchant Marine Academy (USMMA) in Kings Point, New York.
The scope of work includes: site preparation and safety with a site-specific Health and Safety Plan (HASP) addressing lead exposure, respiratory protection, and waste handling; HEPA vacuum cleaning of all interior surfaces (floors, walls, ceilings, target carriers, baffles, traps) using explosion-proof equipment capable of capturing 0.3-micron particulates with 99.97% efficiency; wet-wiping all accessible surfaces with lead-specific cleaning agents; removal and proper containerization of ten (10) existing custom metal-sided HEPA filters (20x32x11.5, 99.97%) from the exhaust system for hazardous disposal; furnishing and installation of ten (10) new custom metal-sided HEPA filters meeting original manufacturer specifications with airflow verification; collection and recycling of spent brass casings with documentation of weight and recycling value to be credited back to USMMA; identification and encapsulation of deteriorated lead-based paint using approved encapsulation systems with minimum two coats of encapsulant, one coat of primer, and two coats of paint on range floors; and characterization, containerization, transport, and disposal of all lead-contaminated waste, filters, and PPE with manifest documentation.
The contract is firm-fixed-price with a five-line CLIN structure: Project Management/Site Preparation (CLIN 0001); Indoor Gun Range Lead Cleaning (CLIN 0002); Exhaust System HEPA Filter Removal/Disposal/Replacement (CLIN 0003 with three sub-CLINs); Lead-Based Paint Encapsulation (CLIN 0004); Hazardous Waste Handling/Transport/Disposal (CLIN 0005); and Brass Casing Recovery Credit (CLIN 0006—NSP deductive CLIN). Performance must be completed within 30 calendar days from Notice to Proceed, with on-site work lasting approximately 3-5 working days during normal business hours (7:00 AM–4:00 PM, Monday–Friday). The project is subject to the Davis-Bacon Act with prevailing wage rates for New York State (Nassau County) as determined by the U.S. Department of Labor at contract award. All work must comply with OSHA 29 CFR 1910 and 1926, EPA, HUD, and New York State lead-safe work practices, and Secretary of the Interior Standards for Treatment of Historic Properties (36 CFR 68 and 67.7) due to USMMA's National Register listing. Deliverables include the approved HASP, daily activity logs, waste disposal manifests, filter cut sheets and installation verification, brass recycling documentation, final completion report with certification of compliance, and encapsulant warranty (minimum 2 years). The contractor is responsible for all subcontractors and must perform recleaning and/or additional encapsulant application at no additional cost until regulatory clearance levels are met. Final payment is made upon receipt of all documents including the final waste manifest.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work (SOW)
1. Background The United States Merchant Marine Academy (USMMA), Kings Point, NY, operates an indoor firearms training range that requires periodic deep cleaning and environmental remediation to ensure compliance with OSHA, EPA, DoD, DHS, MARAD, and New York State regulatory requirements. Work includes management of lead-contaminated dust and debris, firearms range residue, and potentially lead-based paint.
USMMA is listed on the National Register of Historic Places on August 29, 2014. Therefore, all work shall be consistent with the Secretary of the Interior's Standards for the Treatment of Historic Properties (36 CFR part 68). http://www.nps.gov/tps/standards/four-treatments/treatment-guidelines.pdf.
Additionally, all work shall meet or exceed the standards provided in the Secretary of the Interior’s Standards for Rehabilitation and guidelines for applying the standards published by the National Park Service, U.S. Department of the Interior 36 CFR 67.7 - Standards for rehabilitation.”
This SOW describes services for a one-time comprehensive cleaning and remediation of the Bowditch Hall indoor gun range, including exhaust system HEPA filter replacement, brass casing recovery and recycling with credit to USMMA, and encapsulation of any deteriorated lead-based paint.
2. Scope of Work The Contractor shall furnish all labor, supervision, equipment, tools, materials, permits, transportation, and disposal necessary to perform the following tasks:
2.1 Site Preparation and Safety
• Conduct pre-work site inspection and coordination with USMMA facilities and safety personnel.
• Submit a site-specific Health and Safety Plan (HASP) addressing lead exposure, respiratory protection, ventilation isolation, and waste handling.
• Establish containment and negative pressure as required to prevent dispersion of lead-contaminated dust.
• Comply with OSHA 29 CFR 1910 and 1926 standards (including Lead in
Construction).
2.2 Indoor Gun Range Cleaning
• HEPA vacuum all floors, walls, ceilings, target carriers, baffles, traps, and ancillary surfaces, with explosion-proof HEPA equipment capable of capturing a minimum particulate of 0.3 microns with 99.97% efficiency.
• Wet-wipe all accessible horizontal and vertical surfaces using lead-specific cleaning agents.
• Remove accumulated lead dust, unburnt powder residue, and debris generated by firearms use.
2.3 Exhaust System HEPA Filter Removal and Replacement
• Remove and properly containerize ten (10) existing custom metal-sided HEPA
(99.97%) filters (or equivalent) from the range exhaust system.
Custom filters (or equivalent) must meet dimensions/specifications:
(20x32x11.5) 99.97% Metal High-Capacity HEPA – Gasket Downstream
• Transport and dispose of used filters as hazardous waste in accordance with federal and New York State regulations.
• Furnish and install ten (10) new custom metal-sided HEPA (99.97%) filters meeting or exceeding original manufacturer specifications and airflow requirements.
• Verify proper installation, airflow, and seal integrity after replacement.
2.4 Brass/Casing Recovery and Recycling
• Collect spent brass casings from the range floor and traps.
• Separate casings from lead and debris.
• Transport casings to a licensed recycler.
• Provide documentation of weight and recycling value.
• Credit the full recycling value back to USMMA as a line-item deduction.
2.5 Lead-Based Paint Encapsulation
• Identify areas with peeling, chipping, or otherwise loose lead-based paint.
• Stabilize surfaces via surface preparation and application of approved lead encapsulation coating systems.
• No abrasive removal methods permitted.
• Provide a minimum of two (2) coats of encapsulant.
• Range floor (Firing Line to Bullet Trap Area) Encapsulant: minimum two (2) coats Primer: minimum one (1) coat Paint: minimum two (2) coats (ex. interior/exterior porch & floor enamel gray)
• Encapsulation shall comply with EPA and HUD lead-safe work practices.
2.6 Waste Handling and Disposal
• Characterize, containerize, transport, and dispose of all lead-contaminated waste, filters, wipes, PPE, and debris.
• Provide waste manifests and disposal documentation to USMMA.
2.7 Closeout
• Perform post-cleaning visual inspection with USMMA.
• Submit final report including:
o Description of work performed o Waste manifests (including final waste manifests) o HEPA filter specifications o Brass recycling credit documentation o Certification of compliance o Encapsulant warranty (minimum 2 years)
3. Contract Line Item Number (CLIN) Structure The following CLIN structure is provided for use in a firm-fixed-price standalone contract or task order. Prices shall be inclusive of all labor, materials, equipment, supervision, overhead, and profit unless otherwise noted.
CLIN Table CLIN Description Type Qty Unit Notes
Project Management, Site Preparation, and Safety (HASP, containment, supervision)
FFP 1 Lot Includes mobilization and competent person
Indoor Gun Range Lead Cleaning and HEPA Decontamination
FFP 1 Lot Full range interior cleaning
Exhaust System HEPA Filter Removal, Disposal, and Replacement (10 each)
FFP 1 Lot Includes filters and hazardous disposal
0004 Lead-Based Paint Stabilization and Encapsulation FFP 1 Lot Limited deteriorated areas only
0005 Hazardous Waste Handling, Transport, and Disposal FFP 1 Lot Includes manifests and documentation
(NSP)
Brass Casing Recovery and Recycling Credit
FFP
(Credit) 1 Lot Deductive CLIN credited to USMMA Sub-
CLIN
Description Type Qty Unit Notes
0003AA Remove & Dispose Existing HEPA Filters
FFP 10 Each Hazardous waste handling included
0003AB Furnish & Install New Custom HEPA Filters
FFP 10 Each Must meet OEM airflow specifications
0003AC Testing, Balancing, and Seal Verification
FFP 1 Lot Required for acceptance
Note: CLIN 0006 shall be bid as a negative-value CLIN or administratively deducted based on verified recycling documentation.
4. Labor Standards and Wage Determination
• This project is subject to the Davis-Bacon Act.
• The Contractor shall pay not less than the prevailing wage rates and fringe benefits for
New York State (Nassau County) as determined by the U.S. Department of Labor at time of contract award.
5. Period of Performance
• Performance shall be completed within 30 calendar days from Notice to Proceed
(NTP).
• On-site work is anticipated to last approximately 3-5 working days.
6. Deliverables
• Approved HASP
• Daily activity logs
• Waste disposal manifests
• Filter cut sheets and installation verification
• Brass recycling credit documentation
• Final completion report
• Safety Data Sheets (SDS) for encapsulant(s) and paint(s)
7. Notes and Assumptions
• Firm-Fixed-Price anticipated.
• Credit CLIN to be reconciled at closeout.
• Final pricing subject to wage determination at award.
• No structural or HVAC redesign included.
• All work must be completed between normal business hours of operation (7am –
4:00pm), Monday – Friday, unless additional approval is granted by the CO and COR.
• Contractor site visit walkthrough prior to project bid.
• Awarded contractor shall work with the academy’s awarded air monitor/IH specialist.
• Recleaning shall be conducted if current regulatory clearance levels are not met.
• Re-application and/or additional application of encapsulant shall be performed if current regulatory clearance levels are not met.
• Recleaning and/or additional application of encapsulant shall be performed repeatedly until clearance levels are met at no additional cost incurred to USMMA and the government.
• Final payment made after receipt of all documents including final waste manifest.
• Awarded contractor is responsible for ensuring client satisfaction throughout the duration of the work.
• Awarded contractor is responsible for any subcontractors that may be used for this project. Subcontractors are required to adhere to all the requirements set forth within this SOW.
8. Images of Location
Filters Location
| Statement of Work (SOW) |
| 1. Background |
| 2. Scope of Work |
| 2.1 Site Preparation and Safety |
| 2.2 Indoor Gun Range Cleaning |
| 2.3 Exhaust System HEPA Filter Removal and Replacement |
| 2.4 Brass/Casing Recovery and Recycling |
| 2.5 Lead-Based Paint Encapsulation |
| 2.6 Waste Handling and Disposal |
| 2.7 Closeout |
| 3. Contract Line Item Number (CLIN) Structure |
| CLIN Table |
| 4. Labor Standards and Wage Determination |
| 5. Period of Performance |
| 6. Deliverables |
| 7. Notes and Assumptions |
| 8. Images of Location |