Appendix C - Catenary Pole Replacement Schedule for Lowell Trolley System.xlsx
XLSX spreadsheet 14 KB Posted
- Solicitation number
- 6913G624R200002
About this file
This document is an appendix that outlines a schedule for replacing catenary poles on the Lowell Trolley System. It provides detailed information on the work required for each pole, including the type of pole, material, scope of work, and any special instructions. The poles are being replaced with new steel poles, and the work includes installing new catenary wires, relocating telecommunications lines, and repairing surrounding infrastructure as needed. The document references specific details and drawings that provide additional guidance on the pole replacement work. This appendix appears to be supporting a federal contract opportunity for the repair and maintenance of the Lowell National Historic Park trolley track system, which is being solicited by the Department of Transportation.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| CATENARY POLE SCHEDULE | ||||
| Pole No. | Type | Material | Scope of Work | |
| 001 | NA | STEEL | NO ACTION REQUIRED. | |
| N001A | ||||
| N001B | NA | |||
| NA | NEW STEEL | |||
| NEW STEEL | INSTALL TWO NEW STEEL POLES WITH STEEL BEAM AT THE END OF THE DUTTON STREET SPUR BEHIND THE RAIL BUMP STOP TO ANCHOR THE END OF THE NEW CATENARY WIRE. |
SEE DETAIL 1, SHEET C-2, NOTE 2.
| R002 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REINSTALL LIGHTNING ARRESTOR TO NEW GROUND CONNECTION. REMOVE GUY WIRE AND ANCHOR. |
| N003 | C | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. POLE HAS BEEN MOVED SO THAT IT IS EVENLY SPACED BETWEEN THE RAIL WAY AND SPUR. INSTALL TWO CATENARY SUPPORT ARMS FOR RAIL WAY AND SPUR CATENARY WIRES. |
| R004 | D | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. EXTEND CROSSARM TO 20’-6” IN LENGTH TO ALSO CARRY NEW CATENARY WIRE FOR DUTTON STREET SPUR. |
| N005 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. INSTALL NEW CATENARY WIRE ON DUTTON STREET SPUR TO THE EXTENDED CROSSARM AT POLE 004. NEW CATENARY LINE FOR SPUR TO EXTEND TO POLE N003 AND ENDING AT POLES |
N001A & N001B.
| N006 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. REMOVE AND REINSTALL SIGN. |
| N007 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. |
| N008 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. |
| N009 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. REINSTALL SIGN. |
| N0010 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. |
| 011 | A | WOODEN | REMOVE POLE AND CROSSARM. MAINTAIN FUSE LINK ON CATENARY LINE. |
| R011A | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. RE-NUMBER |
AS POLE 011.
R012 A WOODEN REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND
REINSTALL SIGN.
| R013 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R014 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R015 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R016 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R017 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R018 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE GUY WIRE TO POLE 019 |
| R019 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. THIS WILL REQUIRE THE TEMPORARY SUPPORT OF THE CATENARY WIRE AND THE TELECOMMUNICATIONS LINES RUNNING DOWN INTO A CONDUIT. ONCE A NEW STEEL POLE IS INSTALLED, REATTACH THE TELECOMMUNICATIONS CABLE/BUNDLE AND CONDUIT TO THE NEW POLE. CARE MUST BE TAKEN SO THAT NO DISRUPTION IN INTERNET OR TELEPHONE SERVICE IS EXPERIENCED BY THE PARK SERVICE. |
REMOVE AND REINSTALL SIGN. REMOVE AND REINSTALL GUY WIRE TO END OF CROSSARM AT POLE 020.
R020 A WOODEN REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL TELECOMMUNICATIONS CABLE TO NEW STEEL POLE. REMOVE GUY WIRE AND CUT OFF ANCHOR BELOW
GRADE.
| 021 | NA | STEEL | INSTALL NEW POLE CAP. |
| R022 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| 023 | NA | STEEL | INSTALL NEW POLE CAP. |
| 024 | NA | STEEL | NO ACTION REQUIRED. |
| 025 | NA | STEEL | NO ACTION REQUIRED. |
| 026 | NA | STEEL | INSTALL NEW POLE CAP. |
| 027 | NA | STEEL | INSTALL NEW POLE CAP. |
| R028 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. THIS POLE MAY NEED TO BE MOVED AWAY FROM THE B&M LOCOMOTIVE DISPLAY DEPENDING UPON MEANS AND METHODS FOR INSTALLATION. ADJUST CROSSARM LENGTH ACCORDINGLY. REMOVE AND REINSTALL CONDUIT AND WIRING. TRIM TREES AS NECESSARY BETWEEN POLES 028 AND 029. REMOVE AND REINSTALL TELECOMMUNICATIONS CABLE. |
| N029 | A | WOODEN | REPLACE WITH STEEL POLE IN NEW LOCATION. THE POLE IS TO BE MOVED SOUTHWARD BY APPROXIMATELY 2 FEET OFF THE CONCRETE SIDEWALK. ADJUST CROSSARM LENGTH ACCORDINGLY. THE SIDEWALK SHALL BE REPAIRED TO MATCH SURROUNDING CONDITIONS. |
REMOVE AND REINSTALL TELECOMMUNICATIONS CABLE. REMOVE GUY WIRE TO POLES 033 AND 031. REMOVE AND REINSTALL SIGN.
R030 A WOODEN REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL TELECOMMUNICATIONS CABLE. ROMOVE AND REINSTALL SIGN. PROTECT AND REPAIR EXISTING PEDESTRIAN PLATFORM.
NOTE: PROXIMITY OF GAS LINE TO POLE BASE. HAND DIGGING REQUIRED.
| R031 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL TELECOMMUNICATIONS CABLE. NOTE PROXIMITY OF GAS LINE TO POLE BASE. HAND DIGGING REQUIRED. |
| 032A, |
032B, 032C, 032D NA WOODEN WOODEN WOODEN STEEL REMOVE POLES 032A, 032B, 032C AND (STEEL) 032D IN WAY OF THE REMOVED MOODY STREET FEEDER SPUR INCLUDING CATENARY WIRE, GUY WIRES AND ANCHORS. THESE POLES WILL NOT BE REINSTALLED. REMOVE WOODEN POLES TO 2 INCHES BELOW GRADE, BACKFILL, AND FINISH TO MATCH EXISTING SURFACE. CUT STEEL POLE FLUSH AND DELIVER IT TO LNHP MAINTENANCE YARD IN LOWELL.
MOVE TELECOMMUNICATIONS CABLE TO POLE 033 AND COIL EXCESS NEATLY ON POLE 033.
R033 B WOODEN REPLACE WITH STEEL POLE IN SAME LOCATION. TRIM TREES FROM POLE 033 TO POLE 043. NEATLY COIL TELECOMMUNICATIONS CABLE MOVED FROM POLE 032A AND ATTACH TO POLE 033. ADJUST CATENARY WIRE ALIGNMENT TO CENTER OF TRACK WHEN SPUR CATENARY
WIRE IS REMOVED. REDUCE CROSSARM LENGTH AS NECESSARY.
R034 B WOODEN REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE
GUY WIRE TO POLE 032A.
| R035 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R036 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R037 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R038 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R039 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R040 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| R041 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. |
| 042 | NA | STEEL | NO ACTION REQUIRED. |
| R043 | B | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL SIGN. |
| POLE REPLACEMENTS FROM WYE TO SUFFOLF PLATFORM | |||
| R046 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. NO CROSS ARM REQUIRED. REMOVE AND REINSTALL CONDUIT, WIRES AND GUY WIRES. |
| R091 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R092 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R093 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R094 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R095 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R096 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R100 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R101 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R102 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R103 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R104 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
| R105 | A | WOODEN | REPLACE WITH STEEL POLE IN SAME LOCATION. REMOVE AND REINSTALL CONDUIT AND WIRING. |
NOTES FROM DRAWING 475-175272.
Catenary Pole Type A – See Detail 4, Sheet C-2 (Typical Pole Detail) Catenary Pole Type B – See Detail 5, Sheet C-2 (Includes Upper Crossarm) Catenary Pole Type C – See Detail 1, Note 1, Sheet C-2 (Pole N003 - Two Cross Arms at 180 Degrees) Catenary Pole Type D – See Sheet C-1 (Pole R004 - Extended Crossarm to Carry Two Catenary Wires)
File details come from the government source that posted it. Updated .