6805 OEH8 Proposed Signed DLB.pdf

PDF 635 KB Posted

Attached to
Water Service Line Henryetta, OK
Solicitation number
RFQ1514575
Issued by

About this file

This document is a sanitation facilities design and location drawing for an on-site sewer project in Henryetta, Oklahoma, prepared by the Indian Health Service (IHS). The proposed project involves installing a 1,000-gallon rectangular concrete septic tank 16 feet from a home foundation, with a 415 linear foot drainage field using multiple chambers and a 500 linear foot water service line with an isolation valve. The project is located on a track in Section 19, Township 12N, Range 15E in McIntosh County, with a two-bedroom property owned by Rhonda Scott at 104306 S 4080 Rd. The design includes details for an existing septic tank pump to be abandoned and specifications for proposed water infrastructure, including a new RWD meter and water service line, with the site profile completed by Scott Fine on 12/07/2024 and approved by LeRoy Arnold on 4/21/2025.

View the file

Other files

File Type Posted
SF18-95a Request for Quote-r1.docx DOCX document
ok33 (1).txt TXT text file
Construction Clauses-DEVIATION FEB 2025.docx DOCX document
6805 Bid Sheet WSL.xlsx XLSX spreadsheet
6805 SOW WSL HDPE - Esigned.pdf PDF
SF18-95a Request for Quote.docx DOCX document
IHS IEE Representation Form_Jan 2022_508 Compliant.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WSL

WSL

WSL

WSL

WSL

PROPOSED

1000 gal

SEPTIC TANK 16' from Home Foundation

PROPOSED 415 LF MM

3 - 100 LF CHAMBERS

1 - 115 LF CHAMBERS

MIN 8 FT SPACING ON

CENTERS

PROPOSED

500 LF - 2" DR11 HDPE WSL

WITH ISOLATION VALVE

AND VALVE BOX

DRIVEW

AY

H O

U

SE

8'

SOIL PROFILE LIMITS

PROPERTY LINE

16'

8'

EXISTING

SEPTIC TANK PUMP

AND ABANDON

WSL

WSL

WSL

WSL

WSL

WSLWSL

WSL

IN

D

I A N

HEA LTH SER

V

ICE

1 9 5 5

Sanitation Facilities Design & Location

Community On-Site Sewer

Project # County:

Name:

Cistern Pump Well Depth:

On -Site Water Community Water Name:

Septic Tank Lagoon Drain field

Directions To Site: Hwy 266 and S 4080 Rd. Go S on 4080 Rd 0.3 miles. Driveway to the west. Mobile home to the N.

Project Description:

Property Description:

Address:

Capacity: 1000 gal Shape: Material:

Make: Model: Motor Size:

Casing Depth: Diameter: Material:

Yield: S.W.L.: Drawdown:

Drilled By: Date Drilled:

Capacity: Shape: Material:

Total Depth: Length: Width:

Trench Length: 415 LF Trench Width: 24" Material: CHAMBERS

# Of Bedrooms: 2

Name:

Profile By: Scott Fine Profile Date: 12/07/2024

As-Built Proposed

Drawn By:

Reviewed By:

Approved By:

Name Date

OEH & E Field Office Indian Health Service P.O. Box 67 Okmulgee, Ok 74447 Work#: (918)-586-8420

SR # Latitude: Longitude:

LeRoy Arnold 4/21/2025

McIntosh Co. RWD #4

Rhonda Scott McIntosh Track in Sec 19 - T 12N - R 15E

6805 35.503446(N) -95.753599 (W)

104306 S 4080 Rd, Henryetta, OK. 74437

OEH-8 (8/93)

IS & CW

1" = 100''

Track in of Sec 19 - T 12N - R 15E

Aerobic Spray Aerobic Drip

Pump Tank (gal):

Pump Tank:

Req. Spray Area (ft2): Spray Area (ft2):

Drip Line:

SR# 6805

SR# 6801

Proposed RWD Meter

S 4080 R D

Proposed 500 LF

2" DR 11 HDPE WSL w/ Isolation

Valve and Valve Box

Rectangular Concrete

DLB 4/21/2025

OK24-Y31 (Regular)

AutoCAD SHX Text

OE

AutoCAD SHX Text

OE

Sheets and Views
6805 OEH8 Proposed IHS-8.5x11 OEH-8