This document is a sanitation facilities design and location drawing for an on-site sewer project in Henryetta, Oklahoma, prepared by the Indian Health Service (IHS). The proposed project involves installing a 1,000-gallon rectangular concrete septic tank 16 feet from a home foundation, with a 415 linear foot drainage field using multiple chambers and a 500 linear foot water service line with an isolation valve. The project is located on a track in Section 19, Township 12N, Range 15E in McIntosh County, with a two-bedroom property owned by Rhonda Scott at 104306 S 4080 Rd. The design includes details for an existing septic tank pump to be abandoned and specifications for proposed water infrastructure, including a new RWD meter and water service line, with the site profile completed by Scott Fine on 12/07/2024 and approved by LeRoy Arnold on 4/21/2025.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF18-95a Request for Quote-r1.docx | DOCX document | |
| 6805 SOW WSL HDPE - Esigned.pdf | ||
| ok33 (1).txt | TXT text file | |
| Construction Clauses-DEVIATION FEB 2025.docx | DOCX document | |
| 6805 Bid Sheet WSL.xlsx | XLSX spreadsheet | |
| SF18-95a Request for Quote.docx | DOCX document | |
| IHS IEE Representation Form_Jan 2022_508 Compliant.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WSL
WSL
WSL
WSL
WSL
PROPOSED
1000 gal
SEPTIC TANK 16' from Home Foundation
PROPOSED 415 LF MM
3 - 100 LF CHAMBERS
1 - 115 LF CHAMBERS
MIN 8 FT SPACING ON
CENTERS
PROPOSED
500 LF - 2" DR11 HDPE WSL
WITH ISOLATION VALVE
AND VALVE BOX
DRIVEW
AY
H O
U
SE
8'
SOIL PROFILE LIMITS
PROPERTY LINE
16'
8'
EXISTING
SEPTIC TANK PUMP
AND ABANDON
WSL
WSL
WSL
WSL
WSL
WSLWSL
WSL
IN
D
I A N
HEA LTH SER
V
ICE
1 9 5 5
Sanitation Facilities Design & Location
Community On-Site Sewer
Project # County:
Name:
Cistern Pump Well Depth:
On -Site Water Community Water Name:
Septic Tank Lagoon Drain field
Directions To Site: Hwy 266 and S 4080 Rd. Go S on 4080 Rd 0.3 miles. Driveway to the west. Mobile home to the N.
Project Description:
Property Description:
Address:
Capacity: 1000 gal Shape: Material:
Make: Model: Motor Size:
Casing Depth: Diameter: Material:
Yield: S.W.L.: Drawdown:
Drilled By: Date Drilled:
Capacity: Shape: Material:
Total Depth: Length: Width:
Trench Length: 415 LF Trench Width: 24" Material: CHAMBERS
# Of Bedrooms: 2
Name:
Profile By: Scott Fine Profile Date: 12/07/2024
As-Built Proposed
Drawn By:
Reviewed By:
Approved By:
Name Date
OEH & E Field Office Indian Health Service P.O. Box 67 Okmulgee, Ok 74447 Work#: (918)-586-8420
SR # Latitude: Longitude:
LeRoy Arnold 4/21/2025
McIntosh Co. RWD #4
Rhonda Scott McIntosh Track in Sec 19 - T 12N - R 15E
6805 35.503446(N) -95.753599 (W)
104306 S 4080 Rd, Henryetta, OK. 74437
OEH-8 (8/93)
IS & CW
1" = 100''
Track in of Sec 19 - T 12N - R 15E
Aerobic Spray Aerobic Drip
Pump Tank (gal):
Pump Tank:
Req. Spray Area (ft2): Spray Area (ft2):
Drip Line:
SR# 6805
SR# 6801
Proposed RWD Meter
S 4080 R D
Proposed 500 LF
2" DR 11 HDPE WSL w/ Isolation
Valve and Valve Box
Rectangular Concrete
DLB 4/21/2025
OK24-Y31 (Regular)