About this file

This document contains a sketch and specifications for replacing the emergency department roof at a Department of Veterans Affairs medical center. The sketch outlines the location of key features such as air handling units, exhaust fans, and ductwork running across the roof. Debris from the roof replacement project will be removed by crane due to safety concerns with debris chutes on a 10-12 story building. The related federal contract opportunity is solicitation number 667-23-100 for a design-build project to replace the emergency department roof under a firm-fixed-price contract with the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The response due date and award date are not provided in this document.

View the file

Other files

File Type Posted
36C25623R0006 0001.pdf PDF
1675887701205.jpeg JPEG file
1675887593466.jpeg JPEG file
1675887952406.jpeg JPEG file
1675887555487.jpeg JPEG file
ED ROOF - Aerial View.pdf PDF
RFI Responses.docx DOCX document
ED ROOF - Aerial Northwest Quarter.pdf PDF
ED ROOF - Site Grounds Map.pdf PDF
1675887647620.jpeg JPEG file
1675887841057.jpeg JPEG file
1675887758930.jpeg JPEG file
P09 Revised SOW Replace ED Roof- 667-23-100 09-12-2022.docx DOCX document
36C25623R0006 SOLICITATION .pdf PDF
36C25623R0006 - Exhibit A .docx DOCX document
P09 Class II Precautions - Replace ED Roof 667-23-100 Preliminary.docx DOCX document
36C25623R0006 VHA Supplemental Contract Rqts for Combatting COVID-19 (2).docx DOCX document
36C25623R0006 - Exhibit B.docx DOCX document
P09 ICRA - Replace Emergency Department Roof Preliminary.docx DOCX document
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Debris Disposal - will be in a closed container and craned off the roof because debris chutes are not a typical practice for a 10 to 12 story building it has safety concerns and the amount of dust generated from debris falling into the containers below.

AAHU AHU

3N

Hall Exhaust

Hepa Filter Exhaust

Isolation Room Hepa Filter

Exhaust

Exhaust

Decon Exhaust

VHASHRHoffmG Typewritten Text 1N 200B

VHASHRHoffmG Typewritten Text 1N11/1N15

VHASHRHoffmG Typewritten Text 1N22

VHASHRHoffmG Typewritten Text 3N

VHASHRHoffmG Typewritten Text 3N ISO Room

VHASHRHoffmG Typewritten Text 1N11A,17,18,23,24B,24C

VHASHRHoffmG Line

VHASHRHoffmG Typewritten Text

ED ROOF

VHASHRHoffmG Line

VHASHRHoffmG Typewritten Text Door

VHASHRHoffmG Line

VHASHRHoffmG Rectangle

VHASHRHoffmG Rectangle

VHASHRHoffmG Typewritten Text Duct work covering power line/water lines

VHASHRHoffmG Typewritten Text

NOT AIR SUPPLY!

VHASHRHoffmG Line

VHASHRHoffmG Line

VHASHRHoffmG Typewritten Text

NFS

VHASHRHoffmG Line

File details come from the government source that posted it. Updated .