ED ROOF - Sketch.pdf
PDF 1 MB Posted
- Attached to
- 36C25623R0006 - Z1DA--Project #667-23-100 Replace Emergency Department Roof (DB) 36C25623R0006
- Solicitation number
- 667-23-100
About this file
This document contains a sketch and specifications for replacing the emergency department roof at a Department of Veterans Affairs medical center. The sketch outlines the location of key features such as air handling units, exhaust fans, and ductwork running across the roof. Debris from the roof replacement project will be removed by crane due to safety concerns with debris chutes on a 10-12 story building. The related federal contract opportunity is solicitation number 667-23-100 for a design-build project to replace the emergency department roof under a firm-fixed-price contract with the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The response due date and award date are not provided in this document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25623R0006 0001.pdf | ||
| 1675887701205.jpeg | JPEG file | |
| 1675887593466.jpeg | JPEG file | |
| 1675887952406.jpeg | JPEG file | |
| 1675887555487.jpeg | JPEG file | |
| ED ROOF - Aerial View.pdf | ||
| RFI Responses.docx | DOCX document | |
| ED ROOF - Aerial Northwest Quarter.pdf | ||
| ED ROOF - Site Grounds Map.pdf | ||
| 1675887647620.jpeg | JPEG file | |
| 1675887841057.jpeg | JPEG file | |
| 1675887758930.jpeg | JPEG file | |
| P09 Revised SOW Replace ED Roof- 667-23-100 09-12-2022.docx | DOCX document | |
| 36C25623R0006 SOLICITATION .pdf | ||
| 36C25623R0006 - Exhibit A .docx | DOCX document | |
| P09 Class II Precautions - Replace ED Roof 667-23-100 Preliminary.docx | DOCX document | |
| 36C25623R0006 VHA Supplemental Contract Rqts for Combatting COVID-19 (2).docx | DOCX document | |
| 36C25623R0006 - Exhibit B.docx | DOCX document | |
| P09 ICRA - Replace Emergency Department Roof Preliminary.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Debris Disposal - will be in a closed container and craned off the roof because debris chutes are not a typical practice for a 10 to 12 story building it has safety concerns and the amount of dust generated from debris falling into the containers below.
AAHU AHU
3N
Hall Exhaust
Hepa Filter Exhaust
Isolation Room Hepa Filter
Exhaust
Exhaust
Decon Exhaust
VHASHRHoffmG Typewritten Text 1N 200B
VHASHRHoffmG Typewritten Text 1N11/1N15
VHASHRHoffmG Typewritten Text 1N22
VHASHRHoffmG Typewritten Text 3N
VHASHRHoffmG Typewritten Text 3N ISO Room
VHASHRHoffmG Typewritten Text 1N11A,17,18,23,24B,24C
VHASHRHoffmG Line
VHASHRHoffmG Typewritten Text
ED ROOF
VHASHRHoffmG Line
VHASHRHoffmG Typewritten Text Door
VHASHRHoffmG Line
VHASHRHoffmG Rectangle
VHASHRHoffmG Rectangle
VHASHRHoffmG Typewritten Text Duct work covering power line/water lines
VHASHRHoffmG Typewritten Text
NOT AIR SUPPLY!
VHASHRHoffmG Line
VHASHRHoffmG Line
VHASHRHoffmG Typewritten Text
NFS
VHASHRHoffmG Line