657A5-21-401 - Drawings R2_Part7 - 14 pages.pdf

PDF 7 MB Posted

Attached to
Z2DA--657A5-21-401, Construct New Campus Chiller Plant, MRN
Solicitation number
36C25526R0129
Issued by

About this file

This document is a set of contract documents for the Marion VA Medical Center construction project, specifically detailing electrical and technology infrastructure work. The project involves the construction of a new energy center with associated electrical distribution, telecommunications, security, and audiovisual systems.

The electrical scope includes three main distribution panels: Panel 1LLS (208Y/120V, 150A rating), Panel 1LNA (208Y/120V, 150A rating), and Panel 1HNDP1 (480Y/277V, 200A rating), all located in Electrical Room 106. The estimated total demand across panels ranges from 9.79 kVA to 58.29 kVA. The technology infrastructure encompasses data cabling using Category 6A UTP cables, telecommunications outlet labeling schemes with modular jack configurations, wireless access points (WAP) providing network connectivity throughout the facility, and closed-circuit television (CCTV) systems with eight cameras installed at various locations including the chiller plant, electrical rooms, and exterior building corners. Security systems include electronic door controls (EDC) for eight doors plus two gates, card reader access points, intercom stations, and magnetic locks with associated power supplies. The project specifies conduit routing, cable trays, grounding systems, and detailed installation requirements per NEC standards. Installation specifications reference Sections 26 05 33 (Raceway and Boxes Systems), 26 51 00 (Luminaire Installation), 07 84 00 (Firestopping), and related sections. The construction phase is designated as NEW, with contract documents dated 05/07/2026.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

C :\U se rs

\d m br

\A pp D at a\

Lo ca l\A ut od es k\ R ev it\

Au to de sk

R ev it

\C ol la bo ra tio nC ac he

\L Q

C 3M

U F8

4E

LP

\5 d1 ac

3- 2a e8 -4

5-b5 5f

-c ff8

3c 3d

3a

\e e-fd

-4 d-ab

-2 dc f.r vt

5/ 5/

1:

:5

PM

E602

PANEL SCHEDULES

05/07/2026 MSG DMB

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

9.29 kVA 9.79 kVA (27 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes:

Special Circuit Breaker (SCB) Types: GF=GFCI Breaker, ST=Shunt Trip Breaker, AF=AFCI Breaker, GP=GFPE Breaker

Total Est. Demand: 27 A Resistive Heat 4,493 VA 100.00% 4,493 VA Total Conn.: 26 A Receptacle 1,440 VA 100.00% 1,440 VA Total Est. Demand: 9.79 kVA Power 360 VA 100.00% 360 VA Total Conn. Load: 9.29 kVA Motor 2,998 VA 116.68% 3,498 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Load: 3.87 kVA 3.75 kVA 1.68 kVA 41 Spare 20 A 1 0 -- 1 -- Space 42 39 Spare 20 A 1 0 -- 1 -- Space 40 37 Spare 20 A 1 0 -- 1 -- Space 38 35 Spare 20 A 1 0 -- 1 -- Space 36 33 Spare 20 A 1 0 -- 1 -- Space 34 31 Spare 20 A 1 0 -- 1 -- Space 32 29 Spare 20 A 1 0 -- 1 -- Space 30 27 Spare 20 A 1 0 -- 1 -- Space 28 25 Spare 20 A 1 0 -- 1 -- Space 26 23 Spare 20 A 1 0 -- 1 -- Space 24 21 Spare 20 A 1 0 -- 1 -- Space 22 19 Spare 20 A 1 0 -- 1 -- Space 20 17 Spare 20 A 1 0 -- 1 -- Space 18 15 Spare 20 A 1 0 -- 1 -- Space 16 13 Spare 20 A 1 0 -- 1 -- Space 14 11 Spare 20 A 1 0 0.18 1 20 A LCP-1 12 9 Space -- 1 -- 2.246 -- -- -- -- 10 7 Space -- 1 -- 2.246 2 30 A DWH-1 8 5 -- -- -- -- 0.499 1 -- -- -- -- 6

3 VAV-3 15 A 2 0.499 1 2 15 A UH-5 4

1 R. CONTROL ROOM... 20 A 1 1.26 0.36 1 20 A METER CTRL PNL 2

CKT Circuit Description

SCB

Type Trip Poles

A B C Poles Trip

SCB

Type Circuit Description CKT

Voltage: 208Y/120V-3PH-4W Mains Rating: 150 A Supply From: T-1LNA Enclosure: Type 1 Mains Type: MCB

Location: ELECTRICAL ROOM 106 Mounting: Surface A.I.C. Rating: 22KAIC Panel: 1LNA Construction Phase: NEW

2.36 kVA 2.36 kVA (7 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes:

Special Circuit Breaker (SCB) Types: GF=GFCI Breaker, ST=Shunt Trip Breaker, AF=AFCI Breaker, GP=GFPE Breaker

Total Est. Demand: 7 A Total Conn.: 7 A

Power 400 VA 100.00% 400 VA Total Est. Demand: 2.36 kVA Other 500 VA 100.00% 500 VA Total Conn. Load: 2.36 kVA Lighting 1,461 VA 100.00% 1,461 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Load: 0.69 kVA 0.85 kVA 0.82 kVA 29 Spare 20 A 1 0 0 -- -- -- -- 30 27 Spare 20 A 1 0 0 -- -- -- -- 28 25 Spare 20 A 1 0 0 3 20 A SPD 26 23 Spare 20 A 1 0 -- 1 -- Space 24 21 Space -- 1 -- -- 1 -- Space 22 19 Space -- 1 -- -- 1 -- Space 20 17 Space -- 1 -- -- 1 -- Space 18 15 Space -- 1 -- -- 1 -- Space 16 13 Space -- 1 -- -- 1 -- Space 14 11 Space -- 1 -- -- 1 -- Space 12 9 Space -- 1 -- -- 1 -- Space 10 7 Space -- 1 -- -- 1 -- Space 8 5 Lighting 20 A 1 0.424 0.4 1 20 A GEN&ATS PANEL 6

3 LGT CHILLER PLANT... 20 A 1 0.347 0.505 1 20 A LGT CHILLER PLANT... 4

1 FACP 20 A 1 0.5 0.185 1 20 A LGT 2

CKT Circuit Description

SCB

Type Trip Poles

A B C Poles Trip

SCB

Type Circuit Description CKT

Voltage: 208Y/120V-3PH-4W Mains Rating: 100 A Supply From: T-1LLS Enclosure: Type 1 Mains Type: MCB

Location: ELECTRICAL ROOM 105 Mounting: Surface A.I.C. Rating: 10KAIC Panel: 1LLS Construction Phase: NEW

56.42 kVA 58.29 kVA (70 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes:

Special Circuit Breaker (SCB) Types: GF=GFCI Breaker, ST=Shunt Trip Breaker, AF=AFCI Breaker, GP=GFPE Breaker

Resistive Heat 19,493 VA 100.00% 19,493 VA Receptacle 1,440 VA 100.00% 1,440 VA Power 760 VA 100.00% 760 VA Total Est. Demand: 70 A Other 500 VA 100.00% 500 VA Total Conn.: 68 A Motor 25,481 VA 107.36% 27,356 VA Total Est. Demand: 58.29 kVA Lighting 2,740 VA 100.00% 2,740 VA Total Conn. Load: 56.42 kVA

HVAC 6,003 VA 100.00% 6,003 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Load: 20.45 kVA 19.09 kVA 16.88 kVA 53 Spare 20 A 1 0 0 -- -- -- -- 54 51 Spare 20 A 1 0 0 -- -- -- -- 52 49 Spare 20 A 1 0 0 3 60 A SPD 50 47 Spare 20 A 1 0 -- 1 -- Space 48 45 Spare 20 A 1 0 -- 1 -- Space 46 43 Spare 20 A 1 0 -- 1 -- Space 44 41 -- -- -- -- 0 -- 1 -- Space 42 39 -- -- -- -- 0 -- 1 -- Space 40 37 Spare 15 A 3 0 -- 1 -- Space 38 35 -- -- -- -- 0 -- 1 -- Space 36 33 -- -- -- -- 0 -- 1 -- Space 34 31 Spare 20 A 3 0 -- 1 -- Space 32 29 -- -- -- -- 0.023 -- 1 -- Space 30 27 -- -- -- -- 0.023 0 1 20 A Lighting 28

25 LC-1 20 A 3 0.023 2.001 -- -- -- -- 26

23 -- -- -- -- 2.5 2.001 -- -- -- -- 24

21 -- -- -- -- 2.5 2.001 3 15 A VAV-1 22

19 UH-3 15 A 3 2.5 1.209 1 20 A POLE LGT 20

17 -- -- -- -- 2.5 2.5 -- -- -- -- 18 15 -- -- -- -- 2.5 2.5 -- -- -- -- 16

13 UH-2 15 A 3 2.5 2.5 3 15 A UH-4 14

11 -- -- -- -- 2.494 2.5 -- -- -- -- 12 9 -- -- -- -- 2.494 2.5 -- -- -- -- 10

7 VAV-2 15 A 3 2.494 2.5 3 15 A UH-1 8

5 -- -- -- -- 0.685 1.679 -- -- -- -- 6 3 -- -- -- -- 0.824 3.746 -- -- -- -- 4

1 LS-ATS 90 A 3 0.852 3.866 3 70 A T-1LNA 2

CKT Circuit Description

SCB

Type Trip Poles

A B C Poles Trip

SCB

Type Circuit Description CKT

Voltage: 480Y/277V-3PH-4W Mains Rating: 200 A Supply From: US-49 Enclosure: Type 1 Mains Type: MLO

Location: ELECTRICAL ROOM 106 Mounting: Surface A.I.C. Rating: 42KAIC Panel: 1HNDP1 Construction Phase: NEW(NEW) (NEW) (NEW)

1 CONTRACT DOCUMENTS 05/07/2026

DETAIL NOTES

1. FIRESTOP SEALANT, PER SECTION 07 84 00, FIRESTOPPING.

2. MINERAL WOOL. (FIRMLY PACKED)

3. STEEL EXPANSION ANCHOR. TYPICAL.

4. INTERGRAL GALVANIZED LIPPED STELL MOUNTING CHANNEL.

5. CONDUIT FITTING.

6. JUCTION BOX OR PULL BOX. (SIZE AS REQUIRED)

7. SPRING NUT.

8. CONCRETE FLOOR SLAB.

9. CONDUIT.

1 88

3/8" MAX.

[9.52mm]

GENERAL NOTES:

1. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL

LONGER THAN 3'-0" [915mm] SHALL BE INSTALLED WITH

A CENTER SUPPORT ROD. SUPPORT RODS SHALL NOT BE GREATER

THAN 1'-6" [457mm] APART.

2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED METHOD

PER SPECIFICATION 26 05 33, RACEWAY AND BOXES FOR ELECTRICAL

SYSTEMS. FIELD VERIFY EXACT CONDITIONS.

3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS, REFER TO

SPECIFICATION SECTION 13 05 41, SEISMIC RESTRAINT

REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS.

3/8" [9.52mm] MIN. GALVANIZED

THREADED ROD, TYPICAL.

LOCKING SQUARE,

WASHER & LOCKNUT.

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

WASHER & LOCKNUT.

REFER TO PLANS FOR QUANTITY

& SIZE OF CONDUITS.

CONDUIT CLAMP.

SIZE AS REQUIRED.

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

RIGID METAL

CONDUIT FOR

SUPPORT PER

N.E.C. ART. 314

RIGID

METAL

CONDUIT

FOR WIRING

CAST METAL

"WHILE-IN-USE"

WP COVER (S) &

GFCI

RECEPTACLE (S).

CONDUIT

CAP OR

PLUG

ROOF PENETRATION AND

CONDUIT SUPPORT PER

SD260533-05

CAST METAL

"WHILE-IN-USE"

WP COVER (S) &

GFCI

RECEPTACLE (S).

CAST METAL, 2-GANG,

NEMA 3R JUNCTION

BOX WITH THREADED

HUBS.

RIGID METAL

CONDUIT FOR

SUPPORT PER

N.E.C. ART. 314

RIGID

METAL

CONDUIT

FOR WIRING

SECTION "A-A"

ELEVATION

m m

(1 8"

M

A X m m

(1 2"

M

A X

A

A

DETAIL NOTES

1. INSTALLATION IS AN ACCEPTABLE ALTERNATE TO DETAILS SD260533-01.

INSTALLATION IS REQUIRED FOR CONDUIT SMALLER THAN 3" [76mm] ADN

LARGER.

2. PROVIDE EXTRA CABLE LENGTH TO MAKE A COMPLETE LOOP AROUND BOX

PERIMETER.

3. JUNCTION BOX OR PULL BOX. (SIZE AS REQUIRED).

4. EXPANSION FITTING WITH BONDING JUMPER.

5. SPRING NUT.

6. CONDUIT FITTING. TYPICAL.

7. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL.

8. BEAM CLAMP. TYPICAL.

9. STEEL EXPANSION ANCHOR.

10. STRUCTURAL MEMBER (BEAM, JOIST, ETC.) TYPICAL.

11. SEISMIC OR EXPANSION JOINT. FIELD VERIFY ACTUAL CONDITIONS &

LOCATIONS.

12. HEAD.

13. INSULATING BUSHING.

FLOOR OR ROOF STRUCTURE.

FIELD VERIFY ACTUAL

CONDITIONS, TYP.

CONDUIT TRAPEZE PER

SD260533-03. TYP.

CONDUIT. TYP.

3'-0" MAX

[914mm]

CONDUIT TRAPEZE PER

SD260533-03. TYP.

CONDUIT. TYP.

3/8" [9.52mm] MIN. GALVANIZED

THREADED ROD, TYPICAL.

LOCKING SQUARE,

WASHER & LOCKNUT.

REFER TO PLANS FOR QUANTITY

& SIZE OF CONDUITS.

CONDUIT CLAMP.

SIZE AS REQUIRED.

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

UV-INHIBITED POLYCARBONATE OR

HIGH-DENSITY POLYPROPYLENE

PLASTIC BLOCK. LENGTH AS REQUIRED.

DETAIL NOTES

1. CONDUIT CLAMP. SIZE AS REQUIRED.

2. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL.

3. LOCKING SQUARE & LOCK NUT.

4. 3/8" [9.52mm] MIN. GALVANIZED THREADED ROD.

5. STEEL EXPANSION ANCHOR.

6. MULTIPLE MEMBRANE STRIPPING PLIES FEATHERED AT FIELD OF ROOF BY

ROOFING CONTRACTOR. PRIME FLANGE BEFORE STRIPPING.

7. PREFABRICATED FORMED 0.06" [1.52mm] THICK ALUMINUM FLASHING ROUND

COLLAR WITH MINIMUM 3" [76mm] WIDE FLANGE. ATTACHED TO ROOF PER

MANUFACTURER'S INSTRUCTIONS.

8. BATT INSULATION.

9. CONDUIT.

10. SEAL -OFF FITTING.

11. STAINLESS STEEL CLAMP.

12. PREFABRICATED RUBBER BOOT CAP WITH GRADUATED STEPS & WEATHER-

ROOF PRESSURE SEAL TO COLLAR.

13. SEALANT AT PENETRATION TO MEMBRANE JUNCTURE BY ROOFING

CONTRACTOR.

14. ROOF MEMBRANE.

15. CONCRETE DECKING.

16. WATER CUT-OFF MASTIC COMPATIBLE WITH ROOF MEMBRANE.

GENERAL NOTES

1. MAINTAIN A MINIMUM CLEARANCE OF 1'-0" [305mm] ON ALL SIDES OF ROOF

PENETRATION FROM WALLS, CURBS AND OTHER PROJECTION TO FACILITATE

PROPER FLASHING.

2. FLANGES OF ADJACENT FLASHING SHALL NOT BE CUT OR OVERLAPPED.

3. VERIFY ROOF AND STRUCTURAL SYSTEM WITH ARCHITECT.

4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO

ENSURE PROPER METHODS AND MATERIALS ARE USED TO MAINTAIN ROOF

WARRANTY.

. FIELD OF VIEW

16 16

14 14

13 13

11 11

DETAIL NOTES

1. ALL HARDWARE SHALL BE STAINLESS STEEL.

2. PROVIDE ONE MOUNTING POINT PER 12" [305mm] OF BAR LENGTH.

3. HOLES MAYBE ADDED IF REQUIRED.

2'-0" MIN.

[610mm]

1 1/2" TYP.

[38mm]

1" [25mm]

1" [25mm]

1" [25mm]

2" [51mm]

1" [2

5m m

5/ 8"

[1 6m m

2" [5

1m m

4" [1 m m

3/8" [9.52mm] x 5/8" [16mm]

HEX HEAD BOLT.

1/4" [6.35mm] DIA. MOUNTING

HOLES. TYP OF (4)

1/4" [6.35mm] DIA.

HOLES. TYP OF (8)

1/4" [6.35mm] THICK CU BAR

3/8" [9.52mm] DIA. HOLES.

TYP. OF (6)

1/4" [6.35mm] THICK CU BAR

3/8" [9.52mm] x 5/8" [16mm]

HEX HEAD BOLT.

BASE CLAMP/ BRACKET

3/8" [9.52mm] LOCK & FLAT WASHERS

INSULATOR

STEEL EXPANSION

ANCHOR

3/8" [9.52mm] LOCK & FLAT WASHERS

BASE CLAMP/ BRACKET

6'-4" [1930mm]

3'-2" [965mm]

3'-2" [965mm]

3' -1

0" [1

8m m

5' -6

[1

6m m

9' -4

[2

5m m ]A A

POWER

6'-4" [1930mm]

5'-0" [1524mm]

8" [203mm]8"

[2 m m

SUMP 12"x12" [305x305mm]

8" [2 m m

CABLE STANCHION

PER SECTION 26 05 41.

PULLING IRON

GROUND ROD

SLEEVE

9' -4

[2

5m m

8" [2 m m

3" [76mm]

8' -0

[2

8m m

B B

FINISHED GRADE 8"

[2 m m

] GRADE RINGS AS REQUIRED

TO MATCH CIVIL FINISHED

GRADE ELEVATION.

CABLE STANCHION

PER SECTION 26 05 41.

[3 m m

6" [1 m m

CONCRETE ENVELOPE

5'-0" [1524mm]

SUMP FRAME & COVER

SUMP 12" [305mm]

3' -0

[9 m m

3'-0" [915mm]

GRAVEL SUMP

1 CUBIC YARD

[0.764 CUBIC METERS]

3/4" [19mm]

GROUND ROD

PER SECTION

26 05 26.

8" [2 m m

PULLING IRON

7' -4

[2

5m m

V A

R

IE

S

NOTE:

INCLUDE ALUMINUM LADDER. (NOT SHOWN FOR CLARITY)

SLOPE

SLO

PE

S

LO

P E

EQUIPMENT GROUND

CONDUCTOR

MANHOLE COVER FRAME

GROUND CONNECTION

CABLE SPLICES

#6 STRANDED

BARE CU CABLE

(TYP.)

DUCT BANK

CABLE PULLING

IRONS

#3/0 STRANDED

BARE CU

COMPLETE RING

EXOTHERMIC

WELD

CONNECTION

GROUND ROD PER

SPECIFICATION

SECTION 26 05 26

SUMP FRAME

DRILL AND

TAP GROUND

CONNECTION

CABLE CLIP (TYP)

EXOTHERMIC WELD

CONNECTION (TYP)

BRAIDED SHIELD

DRAIN WIRES

(TYP)

EMBEDDED CHANNEL

OR CABLE RACK (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:2

P M

E603

ELECTRICAL DETAILS

05/07/2026 MSG DMB

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

SCALE: NONE

CONDUIT FLOOR SLAB PENETRATION DETAIL

SCALE: NONE

CONDUIT TRAPEZE MOUNTING DETAIL

SCALE: NONE

RECEPTACLE ROOF MOUNTING DETAIL

SCALE: NONE

CONDUIT EXPANSION JOINT CROSSING - EXPANSION FITTING

SCALE: NONE

CONDUIT ROOF SUPPORT DETAIL

SCALE: NONE

CONDUIT ROOF PENETRATION DETAIL

SCALE: NONE

GROUNDING BAR DETAILS

SCALE: NONE

POWER MANHOLE DETAIL

SCALE: NONE

MANHOLE GROUNDING

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING

HARDWARE.

DRYWALL CEILING

CROSS TEE. TYP.

JUNCTION

BOX

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM. TYP.

6.35mm (1/4")

SCREW

LOCKING

SQUARE

WASHER & NUT

GYPSUM BOARD

CEILING MAIN

BEAM

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM. TYP.

INTEGRAL GALVANIZED

LIPPED STEEL MOUNTING

CHANNEL

CEILING MAIN

BEAM

HANGER WIRE & MOUNTING CHANNEL

ATTACHED TO STRUCTURE REFER TO

SPECIFICATION SECTION 26 51 00

FIXTURE WHIP FROM JUNCTION

BOX (1,829mm (6') LONG MAX)

CEILING HANGER

WIRE

DRYWALL CEILING

CROSS TEE. TYP.

FINISHED PAVING

PULLBOX (REFER

TO SPECIFICATIONS)

LINE SIDES OF EXCAVATION

WITH 30 LBS. (13.6 KG)

FELT PAPER.

(4) CONCRETE BRICKS

2"x8"x16" (51mm x 203mm x 406mm)

CLEAN CRUSHED ROCK

3/4" (19mm) CONDUIT(S) WITH BELL ENDS (TYP.)

SIZE, QUANTITY AND WIRING AS

INDICATED ON PLANS

(3 m m

12" (305mm)

V A

R

IE

S

GRADE. FEATHER & TAMP BACKFILL

TO CREATE FLUSH INSTALLATION AND

POSITIVE DRAINAGE AWAY FROM BOX.

PULLBOX (REFER

TO SPECIFICATIONS)

LINE SIDES OF EXCAVATION

WITH 30 LBS. (13.6 KG)

FELT PAPER.

(4) CONCRETE BRICKS

2"x8"x16" (51mm x 203mm x 406mm)

CLEAN CRUSHED ROCK

3/4" (19mm)

CONDUIT(S) WITH BELL ENDS (TYP.)

SIZE, QUANTITY AND WIRING AS

INDICATED ON PLANS

(3 m m

12" (305mm)

V A

R

IE

S

LUMINAIRE

MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG MAX.)

LUMINAIRE.

REFER TO

SCHEDULE

3 TWIST MINIMUM

(TYP)

LUMINAIR SUSPENSION

WIRES REFER TO

SPECIFICATION SECTION

26 51 00 (TYP)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING THE

RECOMMENDED MOUNTING HARDWARE.

ARCHITECTURAL

CEILING GRID

ACOUSTICAL

CEILING TILE (TYP)

LUMINAIRE.

REFER TO

SCHEDULE

ACOUSTICAL

CEILING TILE

(TYP)

LUMINAIRE

MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG MAX.)

LUMINAIRE.

REFER TO

SCHEDULE

3 TWIST MINIMUM

(TYP)

GYPSUM BOARD (TYP)

CEILING CROSS BEAM

CEILING MAIN BEAM

LUMINAIR SUSPENSION

WIRES REFER TO

SPECIFICATION SECTION

26 51 00 (TYP)

CEILING CROSS BEAM

GYPSUM BOARD

DRYWAL BORDER

LUMINAIRE.

REFER TO

SCHEDULE

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING THE

RECOMMENDED MOUNTING HARDWARE.

1/4" CAST IRON WITH

LEGEND "GROUND"

CONCRETE SLAB

GROUND CONNECTOR

(BURNDY TYPE "GAR")

BARE GROUNDING CABLE

(SIZE AS SHOWN ON PLANS)

TO NEXT GROUND ROD

GROUND ROD (SIZE

AS SPECIFIED)

12" DIAMETER X 2'-0"

STANDARD CONCRETE

PIPE WITH HUB

3/0 COPPER CABLE

3/0 COPPER GROUND LOOP CONDUCTOR

CADWELD "TEE" TYPE

EXOTHERMIC CABLE TO

GROUND ROD CONNECTION

CADWELD EXOTHERMIC

CABLE TO GROUND ROD

CONNECTION

3/4" X 10'-0" COPPER - CLAD STEEL

GROUND ROD.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:2

P M

E604

ELECTRICAL DETAILS

05/07/2026 MSG DMB

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

SCALE: 1/2" = 1'-0"

EXIT SIGN MOUNTING GYPBOARD CEILING

SCALE: 1/8" = 1'-0"

UNDERGROUND CONCRETE PULLBOX - PAVED AREA

SCALE: 1/8" = 1'-0"

UNDERGROUND CONCRETE PULLBOX - TURF AREA

SCALE: 1/2" = 1'-0"

LUMINAIRE MOUNTING - LAY-IN CEILING

SCALE: 1/2" = 1'-0"

LUMINAIRE MOUNTING - GYPBOARD CEILING

SCALE: NONE

TEST WELL AND GROUND ELECTRODE

SCALE: NONE

TYPICAL GROUNDING ROD CONNECTION

ABBREVIATIONS

AAP - AREA ALARM PANEL - MEDICAL GAS

ACC - ACCESS

ADJ - ADJUSTABLE

AF - ARC FAULT CIRCUIT INTERRUPTER

AFCI - ARC FAULT CIRCUIT INTERRUPTER

AFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEM

AFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEM

ALT - ALTERNATE

AP - ACCESS PANEL

APPROX - APPROXIMATE

ARCH - ARCHITECT OR ARCHITECTURAL

ASSY - ASSEMBLY

ATS - AUTOMATIC TRANSFER SWITCH

BLDG - BUILDING

BOE - BOTTOM OF EQUIPMENT

BOT - BOTTOM

BTWN - BETWEEN

CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CKT - CIRCUIT

CLG - CEILING

CMU - CONCRETE MASONRY UNIT

CONN - CONNECT OR CONNECTION

CORR - CORRIDOR

CTR - CENTER

D - DEPTH

DET - DETAIL

DIA - DIAMETER

DIM - DIMENSION

DIV - DIVISION

DN - DOWN

DWG - DRAWING

EA - EACH

EC - ELECTRICAL (DIVISION 26)

EJ - EXPANSION JOINT

ELEC - ELECTRICAL

ELEV - ELEVATION OR ELEVATOR

EM - EMERGENCY

EQ - EQUAL

EQS - EQUIPMENT SUPPLIER

EQUIP - EQUIPMENT

ETR - EXISTING TO REMAIN

EX - EXISTING

EXP - EXPANSION

EXT - EXTERIOR

FCE - FIRE CONTROL EQUIPMENT

FF - FINISHED FLOOR ELEVATION

FLR - FLOOR

FSC - FIRE SUPPRESSION (DIVISION 21)

FT - FEET

FTG - FOOTING

GC - GENERAL CONTRACTOR

GF - GROUND FAULT CIRCUIT INTERRUPTER

GFCI - GROUND FAULT CIRCUIT INTERRUPTER OR GOVERNMENT

FURNISHED CONTRACTOR INSTALLED

GFFT - GROUND FAULT FEED THRU

HC - HVAC (DIVISION 23)

HH - HANDHOLE

HP - HORSE POWER OR HIGH POINT

HVAC - HEATING, VENTILATING, AND AIR CONDITIONING

ID - INSIDE DIAMETER

IN - INCHES

KEC - KITCHEN EQUIPMENT CONTRACTOR

L - LENGTH

LBS - POUNDS

MAP - MASTER ALARM PANEL (MEDICAL GAS)

MAX - MAXIMUM

MEZZ - MEZZANINE

MFR - MANUFACTURER

MH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEM

MIN - MINIMUM OR MINUTE

MISC - MISCELLANEOUS

MTD - MOUNTED

MTG - MOUNTING

NIC - NOT IN CONTRACT

NOM - NOMINAL

NTS - NOT TO SCALE

OD - OUTSIDE DIAMETER

OFCI - OWNER FURNISHED CONTRACTOR INSTALLED

OFOI - OWNER FURNISHED OWNER INSTALLED

PC - PLUMBING (DIVISION 22)

PLBG - PLUMBING

RAD - RADIUS

REC - RECESSED

REQD - REQUIRED

RI - ROUGH-IN

S - SURFACE MOUNTED

SC - SECURITY (DIVISION 28)

SCH - SCHEDULE

SHT - SHEET

SMS - SECURITY MANAGEMENT SYSTEM

SPEC - SPECIFICATIONS

SQ - SQUARE

SS - STAINLESS STEEL

SSTV - SURVEILLANCE SYSTEM TELEVISION

STD - STANDARD

STRUC - STRUCTURAL OR STRUCTURE

SUC - SITE UTILITY CONTRACTOR

TC - TECHNOLOGY (DIVISION 27)

TEBC - TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR

TEMP - TEMPERATURE

TOE - TOP OF EQUIPMENT

TYP - TYPICAL

UNO - UNLESS NOTED OTHERWISE

VFD - VARIABLE FREQUENCY DRIVE

VOL - VOLUME

W/ - WITH

W/O - WITHOUT

WP - WEATHERPROOF

ZVC - ZONE VALVE CABINET

T2

B

T2

DETAIL: B = DETAIL DESIGNATION

T2 = SHEET WHERE DETAIL IS LOCATED

SECTION: 1 = SECTION DESIGNATION

T2 = SHEET WHERE SECTION IS LOCATED

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

GENERAL FLOOR PLAN NOTES

CONDUIT RUN IN WALL OR ABOVE CEILING.

CONDUIT RUN IN SLAB OR UNDERGROUND.

CABLE MANAGEMENT SYSTEM PATHWAY.

LADDER TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE.

CM

4"

4"

CABLE TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE.

T2 1 ELEVATION: 1 = ELEVATION DESIGNATION

T2 = SHEET WHERE ELEVATION IS LOCATED

DASH SYMBOL INDICATES PARTICULAR OUTLET, DEVICE, OR EQUIPMENT TO BE REMOVED AND

SUPPORTING CABLING TO BE REMOVED BACK TO SOURCE OF ORIGIN UNLESS NOTED OTHERWISE.

EXISTING OUTLET, DEVICE, OR EQUIPMENT TO REMAIN. MAINTAIN EXISTING CABLING.

XX

XX

X

X

SURFACE MOUNTED OUTLET OR DEVICE. REFER TO PLANS AND DETAILS.#

SECURITY SYMBOLS

CC

1 CCTV SYSTEM CEILING MOUNTED CAMERA. REFER TO CAMERA SCHEDULE FOR MOUNTING HEIGHT AND CAMERA

SPECIFICATIONS. SUBSCRIPT "X" INDICATES ENTRY IN CAMERA SCHEDULE.

X

AV SYMBOLS

SP CEILING MOUNTED STANDARD ROUND PAGING/INTERCOM SYSTEM SPEAKER.

P

SP PENDANT MOUNTED PAGING/INTERCOM SYSTEM SPEAKER.

AV SYMBOLS WITH ELECTRICAL REQUIREMENTS

SJ

SPEAKER JACK PLATE (18" MH UNLESS NOTED OTHERWISE). 3-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE

CEILING, JACK PLATE AND WIRING.

SP

HORN TYPE PAGING/INTERCOM SYSTEM SPEAKER (120" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING, GROMMETED FACEPLATE, SPEAKER, INSTALLATION AND WIRING.

TECHNOLOGY SYMBOLS WITH ELEC. REQUIREMENTS

WALL MOUNTED PHONE OUTLET (46" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLE

CEILING, JACKS, FACEPLATE AND CABLING. REFER TO FACEPLATE DETAILS.

X R

WALL MOUNTED AV OUTLET (84" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLE CEILING, JACKS, FACEPLATE AND CABLING. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. REFER TO FACEPLATE DETAILS.

X V

WALL MOUNTED AV OUTLET (44" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLE CEILING, JACKS, FACEPLATE AND CABLING. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. REFER TO FACEPLATE DETAILS.

CONDUIT SLEEVE / FIRE RATED SLEEVE ASSEMBLY THRU WALL (1-2" SLEEVE UNLESS NOTED OTHERWISE).

J TELECOM BOX AND CONDUIT TO ABOVE ACCESSIBLE CEILING, REFER TO PLANS. REFER TO FACEPLATE DETAILS.

WALL MOUNTED VOICE/DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE

ACCESSIBLE CEILING, JACKS, FACEPLATE AND CABLING. REFER TO FACEPLATE DETAILS.

AP

WALL MOUNTED WIRELESS ACCESS POINT (96” MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE

ACCESSIBLE CEILING, WAP AND CABLING. REFER TO FACEPLATE DETAILS.

FLOOR BOX WITH CONDUIT(S) TO ABOVE ACCESSIBLE CEILING, # INDICATES TYPE, REFER TO FLOOR BOX (FB) SCHEDULE.

SUBSCRIPT "X" INDICATES TECHNOLOGY DEVICE(S), REFER TO TECHNOLOGY DETAILS.

X

POKE-THRU, # INDICATES TYPE, REFER TO POKE-THRU (PT) SCHEDULE. SUBSCRIPT "X" INDICATES TECHNOLOGY DEVICE(S), REFER TO TECHNOLOGY DETAILS.

X

WALL MOUNTED DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE ACCESSIBLE CEILING, JACKS, FACEPLATE AND CABLING. SUBSCRIPT "X" DESIGNATES QUANTITY OF DATA CABLES. REFER TO FACEPLATE DETAILS.

X

OUTLET LOCATED ABOVE ACCESSIBLE CEILING. JACKS, PLENUM RATED SURFACE MOUNT BOX AND CABLING. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. # INDICATES OUTLET TYPE ON THIS LEGEND, REFER TO FACEPLATE DETAILS.

X

SECURITY SYMBOLS WITH ELECTRICAL REQUIREMENTS

CC

CCTV SYSTEM WALL MOUNTED CAMERA (REFER TO CAMERA SCHEDULE FOR MOUNTING HEIGHT AND CAMERA SPECIFICATIONS). SUBSCRIPT "X" INDICATES ENTRY IN CAMERA SCHEDULE. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE

ACCESSIBLE CEILING, CAMERA AND CABLING.

IC

WALL MOUNTED INTERCOM DOOR STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO

ABOVE ACCESSIBLE CEILING, INTERCOM AND CABLING.

DM

DOOR POSITION SWITCH WITH WIRING. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, PROVIDE ONE CONTACT FOR EACH LEAF IN MULTI-DOOR OPENINGS. REFER TO SECURITY

ROUGH-IN DETAILS.

EL

ELECTRONIC DOOR LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING AND CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, REFER TO SECURITY ROUGH-IN DETAILS.

EM

ELECTRONIC MAG LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING AND CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, REFER TO SECURITY ROUGH-IN DETAILS.

ES

ELECTRONIC STRIKE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING AND CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, REFER TO SECURITY ROUGH-IN DETAILS.

RX

REQUEST TO EXIT SWITCH IN DOOR HARDWARE BY OTHERS. LOW VOLTAGE WIRING. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, REFER TO SECURITY ROUGH-IN DETAILS.

HD

HANDICAP DOOR OPERATOR MOTOR ASSEMBLY BY OTHERS. 120V POWER CONNECTION AND CONDUIT FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, LOW VOLTAGE WIRING AND INTERFACE WITH SMS

AND DOOR ACTUATOR BUTTONS. REFER TO SECURITY ROUGH-IN DETAILS.

HA

WALL/PEDESTAL MOUNT HANDICAP DOOR ACTUATOR BUTTON, FURNISHED BY OTHERS. BOX AS REQUIRED BY SYSTEM MANUFACTURER WITH INSTALLATION AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, ALL LOW VOLTAGE WIRING AND INTERFACE WITH SMS AND DOOR MOTOR. REFER TO SECURITY ROUGH-IN DETAILS.

HO

FA

WALL/FLOOR MOUNTED ELECTROMAGNETIC DOOR HOLD OPEN WITH POWER SUPPLY INSTALLED BY OTHERS. 120V POWER AND CONNECTION, BOX AS REQUIRED BY MANUFACTURER AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, LOW VOLTAGE WIRING FROM POWER SUPPLY TO HOLD OPEN AND INTERFACE WITH SMS.

SUBSCRIPT "FA" INDICATES DEVICES POWERED FROM FIRE ALARM SYSTEM AND INTERFACE FROM SMS TO FIRE ALARM

SYSTEM REQUIRED FOR DOOR RELEASE. REFER TO SECURITY ROUGH-IN DETAILS.

CR

GOOSENECK PEDESTAL PROXIMITY CARD READER (42" AND 64" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH CONDUIT TO COMMON SMS JUNCTION BOX, CARD READER AND CABLING. REFER TO SECURITY ROUGH-IN DETAILS.

KC

WALL MOUNTED COMBINATION KEYPAD/CARD READER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75"

CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING, DEVICE AND CABLING.

X

PB W

WALL MOUNTED PUSH BUTTON FOR LOCAL ELECTRONIC DOOR RELEASE (46" MH UNLESS NOTED OTHERWISE). 1-GANG

BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING, BUTTON AND CABLING.

PL

SITE POLE FOR MOUNTING SECURITY CAMERAS (REFER TO SPECIFICATIONS FOR SIZE/TYPE). PROVIDE POLE WITH CONCRETE BASE AS INDICATED ON PLANS. EXTEND AND CONNECT TO SITE CONDUIT SYSTEM AS INDICATED ON PLANS.

PROVIDE NEMA 3R JUNCTION BOX AT BASE OF POLE FOR CAMERA EQUIPMENT (120V POWER SUPPLY, FIBER

CONVERTERS, ETC.). REFER TO SECURITY ROUGH-IN DETAILS.

EDC

X ELECTRONIC DOOR CONTROL. SUBSCRIPT "X" INDICATES SPECIFIC DOOR. REFER TO ELECTRONIC DOOR CONTROL

SCHEDULE FOR REQUIREMENTS.

TECHNOLOGY SYMBOLS

AP CEILING MOUNTED WIRELESS ACCESS POINT WITH DATA DROP ABOVE CEILING. PROVIDE 10' COIL IN DATA CABLE TO

FACILITATE FUTURE RELOCATION OF WAP.

WIREMOLD RACEWAY, AS NOTED ON PLANS.

NOTE:

ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO

MODIFICATIONS ON OTHER DRAWINGS.

ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT

NECESSARILY BE USED ON THIS PROJECT.

IM DESK MOUNTED INTERCOM MASTER STATION.

A. CONDUITS SHALL BE MINIMUM 1" UNLESS OTHERWISE NOTED.

B. ALTERNATIVE ROUTES MAYBE UTILIZED, WHICH ARE COORDINATED WITH THE GOVERNMENT

AND OTHER TRADES. FINAL ROUTING OF TELECOMMUNICATIONS CABLING SHALL BE

APPROVED BY COR.

C. ALL JUNCTION BOXES ARE TO BE FLUSH MOUNTED UNLESS OTHERWISE NOTED.

D. VERIFY EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH REFLECTED CEILING PLAN

AND/OR ARCHITECT PRIOR TO ROUGH-IN. COORDINATE LOCATIONS OF CEILING MOUNTED

DEVICES WITH LIGHT FIXTURES, MECHANICAL DUCTS, AND SPRINKLER PIPES AND HEADS

BEFORE ROUGH-IN TO PREVENT CONFLICTS.

E. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS

OF OUTLETS AND DEVICES.

F. COORDINATE EXACT LOCATION OF ALL SWITCHES, RECEPTACLES, DATA OUTLETS, VOLUME

CONTROLLERS, AV SYSTEM CONTROLLERS, THERMOSTATS, ETC. WITH RESPECTIVE TRADE

DIVISION PRIOR TO ROUGH-INS. ALL MOUNTING HEIGHTS OF DEVICES WHICH ARE MOUNTED

ADJACENT TO EACH OTHER SHALL BE AT THE SAME DISTANCE MEASURED ABOVE THE

FINISHED FLOOR.

G. STAGGER RECEPTACLES AND OTHER RECESSED OUTLETS WHEN LOCATED ON OPPOSITE

SIDES OF PARTITION / WALL TO ELIMINATE SOUND TRANSMISSION FROM ONE SPACE TO THE

OTHER.

H. WHERE DEVICES ARE MOUNTED IN AREAS WHERE THERE ARE EXPOSED CEILINGS,

COORDINATE THE EXACT MOUNTING / LOCATION WITH THE STRUCTURAL SUPPORT

MEMBERS AND WORK OF OTHER TRADES. PROVIDE ALL NECESSARY LABOR AND MATERIALS

TO ACHIEVE MOUNTING HEIGHTS AND LOCATIONS AS INDICATED ON THE PLANS.

I. REFER TO ARCHITECTURAL DRAWINGS AND COORDINATE ANY EXPOSED CONDUITS WITHIN

THE FINISHED PORTIONS OF THE BUILDING FOR PRIME AND PAINTING REQUIREMENTS.

J. ALL EMPTY CONDUITS SHALL BE INSTALLED WITH PULL STRING.

K. WHERE WALLS ARE FURRED ON ONE SIDE, ALL NEW SERVICES SHALL BE INSTALLED IN THE

WALL FROM THE FURRED OUT SIDE OF THE WALL.

L. ALL CONDUIT SLEEVES AND PATHWAYS SHOWN ON BID DOCUMENTS SHALL BE PROVIDED.

ALL CONDUIT SLEEVES THRU WALLS AND FLOORS, NOT SPECIFICALLY SHOWN ON DRAWINGS

BUT REQUIRED FOR COMPLIANT INSTALLATION OF CABLING SHALL BE PROVIDED AS PART OF

THE SCOPE OF WORK.

M. COMPLETELY AND THOROUGHLY COORDINATE ALL PATHWAYS BEING PROVIDED. ANY

PATHWAYS THAT ARE PROVIDED THAT CAUSE CABLING INSTALLATION TO BE NON-

COMPLIANT SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE

INSTALLATION OF CABLING.

N. A 3.5" DEEP MASONRY BOX SHALL BE USED IN CMU WALLS.

O. BOND ALL CABLE RUNWAY SPLICES AND BUTT JOINTS WITH #6 AWG BOLTED TO CABLE

RUNWAY. REMOVE PAINT OFF OF CABLE RUNWAY FOR METAL TO METAL CONNECTION AND

APPLY ANTI-OXIDANT JOINT COMPOUND OVER ANY REMAINING AREAS WITH BARE METAL

EXPOSED.

P. ALL CONDUITS AND SLEEVES SHALL HAVE NYLON BUSHINGS INSTALLED.

Q. PULL BOXES SHALL NOT BE USED TO CHANGE DIRECTION AND SHALL BE INSTALLED IN LINE

WITH CONDUIT.

R. ALL INTERIOR OF PRECAST CONCRETE WALLS TECHNOLOGY DEVICES SHALL BE SURFACE

MOUNTED.

GENERAL NOTES

AP

P

PENDANT MOUNTED WIRELESS ACCESS POINT WITH DATA DROP. PROVIDE 10' COIL IN DATA CABLE TO FACILITATE

FUTURE RELOCATION OF WAP.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:3

P M

T001

TECHNOLOGY LEGEND

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

DN

CC

EDC

GATE 2

EDC

GATE 1

CR

42" MH

CR

64" MH

CR

42" MH

CR

64" MH

BLDG #2

BLDG #37

EDUCATIONAL

BUILDING BLDG #38

DENTAL/MEDICAL

VENDING/BUILDING

MANAGEMENT & SPD

EXISTING

CHILLER

PLANT 49

NEW HANDHOLE A-1

EXISTING TELECOMMUNICATIONS

MANHOLE 49-1 PATHWAY "A"

NEW 2-4" CONDUITS PATHWAY "C"

PL2

NEW HANDHOLE A-3

NEW HANDHOLE A-2

1-4" CONDUIT

1-4" CONDUIT

2-4" CONDUITS

MOD-1

EXISTING PATHWAY "A"

EXISTING PATHWAY "A"

NEW PATHWAY "B"

NEW PATHWAY "B"

2-4" CONDUIT

NEW HANDHOLE 37-1

NEW HANDHOLE 37-2 1 2

NEW MANHOLE 37-3

MH

MH

1-4" CONDUIT

COMMUNICATIONS

(2) x 4" CONDUIT

4" MAXCELL 3-CELL FABRIC INNERDUCT,

A HIGH-CAPACITY , FLEXIBLE, MULTI-

CELL CONDUIT SYSTEM.

(2) x 4" CONDUIT

GROUND LINE

TOP LEVEL

OF CONCRETE

12 28

4" MAXCELL 3-CELL FABRIC INNERDUCT,

A HIGH-CAPACITY , FLEXIBLE, MULTI-

CELL CONDUIT SYSTEM.

(1) x 4" CONDUIT

4" MAXCELL 3-CELL FABRIC INNERDUCT,

A HIGH-CAPACITY , FLEXIBLE, MULTI-

CELL CONDUIT SYSTEM.

(1) x 4" CONDUIT

4" MAXCELL 3-CELL FABRIC INNERDUCT,

A HIGH-CAPACITY , FLEXIBLE, MULTI-

CELL CONDUIT SYSTEM.

GENERAL NOTES

A. CONCRETE SHALL BE 3000 LB @ 28 DAYS, OR AS SPECIFIED.

B. PROVIDE #4 REINFORCING RODS ON TOP AND BOTTOM OF DUCTS WHEN

CROSSING OR PLACED IN ROADWAYS.

C. PROVIDE MINIMUM 2'-3" COVER OF TAMPED BACKFILL OVER TELECOMMUNICATIONS

DUCT BANK. INSTALL RED DYE, RED DUST, OR YELLOW WARNING MARKER TAPE AT

1'-6" BELOW FINISHED GRADE, AND CENTERED IN RELATION TO DUCT BANK, WITHIN

COMPACTED FILL TO INDICATE UNDERGROUND COMMUNICATIONS

INFRASTRUCTURE.

D. PROVIDE MINIMUM 3" SPACING BETWEEN CONDUITS AND MINIMUM 3" ENCASEMENT,

AND WHEN PARALLEL TO POWER, PROVIDE A MINIMUM OF 6" SPACE BETWEEN

POWER AND TELECOMMUNICATION DUCT BANKS. INCREASE SIZE AS REQUIRED.

E. FOR THE LOCATION OF 4-4" DUCT BANK, ADD INTERMEDIATE SPACER ON A MAX 5'-0"

CENTERS.

3" 3"

3"3"

2 - WAY DUCT LINE

3" 3"

3"3"

1 - WAY DUCT LINE

3" 3"

3"3"

3"

3"

3"

4- WAY DUCT LINE

DETAIL NOTES

1. (1) 4" MAXCELL 3-CELL FABRIC INNERDUCT WITH PULL STRINGS IN EACH CELL,

INCLUDED IN EACH 4" CONDUIT.

1 1 1

NEW

ENERGY

CENTER

ROOM

TR-102

(1) 24 STRAND OM4-(DATA)

(1) 12 STRAND OS2-(BAS)

(2) 04 STRAND OS2 FOR PACS/

AND SSTV

(1) 04 STRAND OS2 FOR PACS

VEHICLE

GATE

LIGHT

POLE

VEHICLE

GATE

(1) 04 STRAND OS2 FOR SSTV

(1) 04 STRAND OS2 FOR PACS

(1) 04 STRAND OS2 FOR PACS

(1) 04 STRAND OS2 FOR SSTV

(1) 24 STRAND OM4-(DATA)

(1) 12 STRAND OS2-(BAS)

FROM BUILDING 37

EXISTING EHRM FIBER 49-1

PATHWAY "A"

EXISTING MANHOLE 49-1 PATHWAY "A"

CONTINUATION OF

EXISTING EHRM FIBER PATHWAY "A"

NEW HAND HOLE A-3

NEW HAND HOLE A-1

NEW HAND HOLE A-2

NEW HANDHOLE 37-2

NEW HANDHOLE 37-1

EXISTING

BUILDING

BLDG #37

NEW MANHOLE 37-3

(1) 24 STRAND OM4-(DATA)

(1) 12 STRAND OS2-(BAS)

(1) 14AWG/2C FOR AUDIO

FROM BUILDING #37

(1) 24 STRAND OM4-(DATA)

(1) 12 STRAND OS2-(BAS)

(1) 14AWG/2C FOR AUDIO

FROM BUILDING #37

(1) 24 STRAND OM4-(DATA)

(1) 12 STRAND OS2-(BAS)

(1) 14AWG/2C FOR AUDIO

FROM BUILDING #37

APPROX WEIGHT:

13,150 LBS.

APPROX. WEIGHT:

15,150 LBS.

1-1/2" R-30

RING AND COVER

7'-0"

12" REDUCING CONE

MODEL 3630-R12

7'-0"

4'-0"

3'-0"

6'-0"

OVERALL

6" GRADE RING

MODEL 3606

PULLING IRON

2 TOTAL

12-0"

OVERALL

11'-0"

5'-0"

(4) PREDRILLED

HOLES FOR

CONDUITS TYP.

(4) PREDRILLED

HOLES FOR

CONDUITS TYP.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:5

P M

TS100

TECHNOLOGY SITE PLAN

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

1" = 30'-0"

SITE PLAN - TECHNOLOGY

A. COORDINATE ALL UNDERGROUND CONDUIT WITH ALL EXISTING AND NEW UNDERGROUND UTILITIES

SHOWN ON CIVIL DRAWINGS.

B. COORDINATE ALL TRENCHING, CONDUIT ROUTING, AND CABLE PATHWAY INSTALLATION WITH OTHER TRADES AND THE COR TO MINIMIZE DISRUPTION TO EXISTING SERVICES. VERIFY EXISTING UTILITIES AND

COORDINATE ANY REQUIRED OUTAGES IN ADVANCE.

C. REFER TO DUCT BANK PROFILE ON THIS SHEET.

D. REFER TO CIVIL SITE PLANS AND SURVEYING DATA FOR LOCATIONS OF EXISTING SYSTEMS.

E. ALL UNDERGROUND CONDUIT ROUTING WILL BE ENCASED IN CONCRETE.

F. PROVIDE IN SCHEDULE 40 PVC 4" CONDUITS, MAXCELL 3-CELL INNERDUCT.

G. SEE SHEET T103 BUILDING #37 FOR ADDITIONAL INFORMATION.

GENERAL NOTES

NTS

2X4 QUAZITE HANDHOLE BOX

NTS

DUCT BANK DETAIL

NTS

SITE FIBER RISER DIAGRAM

NORTH

1. PROVIDE CONDUIT BETWEEN MAIN FIBER DISTRIBUTION ROM IN B37 FOR CONNECTION OF PATH "B FIBER TO NEW CHILLER BUILDING. PATH SHALL BE A CONCRETE ENCASED DUCT BANK THAT INCLUDES (2) 4" CONDUIT AND (3) 3 CELL, 4" FABRIC INNDERDUCT PER CONDUIT. PROVIDE (2) 24 STRAND OM4. PROVIDE 14AWG/2C FOR

AUDIO PAGING INTO NEW CHILLER BUILDING.

2. PROVIDE HANDHOLE FOR PATHWAY "B" FIBER. APPROXIMATE LOCATION OF NEW HANDHOLE, COORDINATE

LOCATION WITH OTHER TRADES PRIOR TO ROUGH-IN.

3. ROUTE FIBER OPTIC AND COPPER CABLING FROM NEW BUILDING "ENERGY CENTER", ROOM TR-102 VIA NEW PATHWAY "C" TO MANHOLE 49-1. CONTINUE FROM MANHOLE 49-1 ALONG EXISTING PATHWAY "A" TO BUILDING # 37, EDUCATIONAL BUILDING MDF. COORDINATE WITH EXISTING CONDITIONS AND AVOID DISRUPTIONS TO

ACTIVE SYSTEMS.

PLAN NOTES

NTS

MANHOLE DETAIL 37-3

2D

2D

2D2D

2D

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:4

P M

TD101

TECHNOLOGY FLOOR PLAN -

DEMOLITION

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

1/4" = 1'-0"

BUILDING 49 FIRST FLOOR - DEMOLITION

SITE KEY PLAN

NEW CHILLER PLANT - BLDG 49

EXISTING CHILLER PLANT - BLDG 49

37MOD-5

MOD-1

MOD-4

MOD-6

NORTH

GENERAL NOTES:

A. CONTRACTOR SHALL COORDINATE WITH THE OWNER IN REGARD TO REMOVALS. DIV 27 AND DIV 28 SHALL FULLY TEST ALL ELECTRONICS PRIOR TO REMOVAL AND PROVIDE WRITTEN DOCUMENTATION OF EQUIPMENT CONDITION AND DISPOSITION TO THE OWNER BEFORE DEMOLITION ACTIVITIES BEGIN. TECHNOLOGY EQUIPMENT INDICATED FOR DEMOLITION SHALL BE REMOVED, TAGGED, AND RETURNED TO THE OWNER FOR STORAGE AND/OR REUSE / REPURPOSING. ALL FIBER OPTIC AND COPPER CABLING FOR

COMMUNICATIONS, INTO BUILDING 49 SHALL BE REMOVED BACK TO BUILDING #37.

3D

3D

3D

3D

AP

P

AP

P

AP

P

AP

P

AP

P

CC

CC

CC

CC

CC

CC

EDC

EDC

EDC

EDC

EDC

EDC

KC

KC

KC

KC

KC

KC

EDC

IM

IC

IC

2D

2D

2D

R

114" MH

SP

P120" AFF

SP

P120" AFF

SP

P120" AFF

SP

P120" AFF

SP

96" MH

SP

96" MH

SP

96" MH

SP

P 120" AFF

SP

P 120" AFF

SP

P 120" AFF

SP

P 120" AFF

SP

P120" AFF

SP

SP

SP

KC

EDC

2D

2D

2D

CC

3D

3D

2D

96" MH

SP

KC

A

D

632 54

B

C

CHILLER PLANT

CONTROL ROOM

H.A.C.

TR

ELECTRICAL ROOM

ELECTRICAL ROOM

T401

100B

105A

100A 100

106A

TOILET

138" AFF 120" AFF

120" AFF

120" AFF120" AFF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:3

P M

T101

TECHNOLOGY FLOOR PLAN - NEW

WORK

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

1/4" = 1'-0"

TECHNOLOGY FIRST FLOOR

SITE KEY PLAN

NEW CHILLER PLANT - BLDG 49

EXISTING CHILLER PLANT - BLDG 49

37MOD-5

MOD-1

MOD-4

MOD-6

NORTH

PLAN NOTES:

1. INTERCOM DOOR ALERT EDWARDS SIGNALING 435-4E1 OR EQUAL.

2. FIELD COORDINATE THE EXACT LOCATION OF THE DATA JACK AT THE CHILLER CONTROL PANEL WITH MECHANICAL AND ELECTRICAL TRADES PRIOR TO INSTALLATION. PROVIDE NEMA-RATED ENCLOSURE FOR PHYSICAL PROTECTION OF DATA JACK AND ASSOCIATED CABLING. COORDINATE ENCLOSURE TYPE AND MOUNTING WITH EQUIPMENT CLEARANCES AND FIELD

CONDITIONS.

3. FIELD COORDINATE THE EXACT LOCATION OF THE DATA JACK AT THE METER ENCLOSURE WITH ELECTRICAL TRADES PRIOR TO INSTALLATION. PROVIDE NEMA-RATED ENCLOSURE FOR PHYSICAL PROTECTION OF DATA JACK AND ASSOCIATED CABLING.

COORDINATE ENCLOSURE TYPE AND MOUNTING WITH EQUIPMENT CLEARANCES AND FIELD CONDITIONS.

4. FIELD COORDINATE THE EXACT LOCATION OF THE DATA JACK AT THE METER SWITCHBOARD WITH ELECTRICAL TRADES PRIOR TO INSTALLATION. PROVIDE NEMA-RATED ENCLOSURE FOR PHYSICAL PROTECTION OF DATA JACK AND ASSOCIATED CABLING.

COORDINATE ENCLOSURE TYPE AND MOUNTING WITH EQUIPMENT CLEARANCES AND FIELD CONDITIONS.

5. PROVIDE WEATHERPROOF BACK BOX WITH WEATHERPROOF COVER PLATE TO PROTECT FROM WATER/PIPE LEAKS.

GENERAL NOTES:

A. ROUTE ALL DIVISION 27 AND 28 CABLING BETWEEN DEVICES AND TR-102 IN CONDUIT UNLESS OTHERWISE NOTED. CONDUIT SHALL BE CONTINUOUS AND PROPERLY SUPPORTED, WITH BENDS AND SIZING IN ACCORDANCE WITH APPLICABLE STANDARDS.

AP

P

2D

2D

AP

P

60" MH

SP

60" MH

SP

76" MH

SP

A

D

632 54

B

C

A

D

1 32

B

C

A.4

A.6

MEZZANINE

96" AFF

84" AFF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:3

P M

T102

MEZZANINE FLOOR - NEW WORK

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

1/4" = 1'-0"

TECHNOLOGY 02-MEZZANINE

SITE KEY PLAN

NEW CHILLER PLANT - BLDG 49

EXISTING CHILLER PLANT - BLDG 49

37MOD-5

MOD-1

MOD-4

MOD-6

NORTH

PLAN NOTES:

1. FIELD COORDINATE THE EXACT LOCATION OF THE DATA JACK AT OR IN THE CONTROL PANEL WITH MECHANICAL AND ELECTRICAL TRADES PRIOR TO INSTALLATION. PROVIDE NEMA-RATED ENCLOSURE FOR PHYSICAL PROTECTION OF DATA JACK AND ASSOCIATED CABLING. COORDINATE ENCLOSURE TYPE AND MOUNTING WITH EQUIPMENT CLEARANCES AND FIELD

CONDITIONS.

2. PROVIDE PATHWAYS AT THE MEZZANINE LEVEL FOR CONDUITS ENTERING TR-102. ROUTE CONDUITS TO TERMINATE ABOVE THE LADDER RACK AND COORDINATE ENTRY LOCATIONS WITH EQUIPMENT LAYOUT. BOND AND GROUND ALL CONDUITS TO THE SBB IN THE TR. SEAL ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES WITH APPROVED FIRESTOP SYSTEMS TO MAINTAIN THE

RATING.

GENERAL NOTES:

A. ROUTE ALL DIVISION 27 AND 28 CABLING BETWEEN DEVICES AND TR-102 IN CONDUIT UNLESS OTHERWISE NOTED. CONDUIT SHALL BE CONTINUOUS AND PROPERLY SUPPORTED, WITH BENDS AND SIZING IN ACCORDANCE WITH APPLICABLE STANDARDS.

2 3 4 51

A

B

C

D

E

T/C ELEC

COMPUTER

ROOM

TELEPHONE

LIBRARY

CM CM

CM

CM

EXISTING

PATHWAY "A"

NEW PATHWAY "B"

CM

105A 105

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:3

P M

T103

BUILDING 37 FLOOR PLAN

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 37

MARION VA

MEDICAL

CENTER Approved: Owner

1/8" = 1'-0"

TECHNOLOGY FIRST FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:3

P M

T103

BUILDING 37 FLOOR PLAN

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 37

MARION VA

MEDICAL

CENTER Approved: Owner

SITE KEY PLAN

NEW CHILLER PLANT - BLDG 49

EXISTING CHILLER PLANT - BLDG 49

37MOD-5

MOD-1

MOD-4

MOD-6

NORTH

PLAN NOTES:

1. EXISTING EHRM PATHWAY "A": FIELD VERIFY PATHWAY ROUTING AND AVAILABLE SPACE WITH ROOM TO ACCOMMODATE NEW FIBER OPTIC AND COPPER CABLING FROM BUILDING 37 EDUCATIONAL BUILDING MDF. COORDINATE WITH EXISTING CONDITIONS

AND AVOID DISRUPTION TO ACTIVE SYSTEMS.

2. NEW PATHWAY "B" CORE DRILL AND OR SAW CUT AS REQUIRED TO ACCOMMODATE CONDUIT ENTRY. PROVIDE SLEEVES WHERE APPLICABLE. ALL CONDUIT PENETRATIONS SHALL BE SEALED WATERTIGHT AND INSECT-TIGHT USING APPROVED SEALANTS AND FIRESTOP SYSTEMS (WHERE RATED ASSEMBLIES ARE PENETRATED). ENSURE SEALS ARE DURABLE, UV-RESISTANT (WHERE

EXPOSED) AND COMPATIBLE WITH CONDUIT AND WALL MATERIALS.

1 CONTRACT DOCUMENTS 05/07/20261 CONTRACT DOCUMENTS 05/07/2026

EDC

KC

CC

T

C

TR

T401 3

T401

T401

14 18

16 21 22

C

14 18

66 BLOCK

110 BLOCK

9 9

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

:4

P M

T401

TECH ROOM PLAN AND

ELEVATIONS

05/07/2026 JCM GES

CONSTRUCT NEW

CAMPUS CHILLER PLANT

657A5-21-401

2401 W MAIN ST, MARION IL 62959

CONTRACT

DOCUMENTS 49

MARION VA

MEDICAL

CENTER Approved: Owner

1/2" = 1'-0"

BUILDING A - TECHNOLOGY ENLARGED PLAN TR 102

1/2" = 1'-0"

TR 102 NORTH WALL ELEVATION

1/2" = 1'-0"

TR 102 EAST WALL ELEVATION

1/2" = 1'-0"

TR 102 SOUTH WALL ELEVATION

1/2" = 1'-0"

TR 102 WEST WALL ELEVATION

SITE KEY PLAN

NEW CHILLER PLANT - BLDG 49

EXISTING CHILLER PLANT - BLDG 49

37MOD-5

MOD-1

MOD-4

MOD-6

NORTH

1 1/2" = 1'-0"

FRONT RACK ELEVATION

1 1/2" = 1'-0"

BACK RACK ELEVATION

RACK ELEVATION GENERAL NOTES

A. FINAL QUANTITY OF (2) HORIZONTAL CABLING PATCH PANELS AND (2) NETWORK EDGE SWITCHES.

B. ALL WORK SHALL BE IN CONFORMANCE WITH INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES (USE LATEST AT TIME

OF BIDDING) VERSION 5.0 JULY 22, 2025.

C. FINAL RACK CONFIGURATIONS INCLUDING LOCATION AND ORIENTATION IN EACH ROOM SHALL BE COORDINATED WITH STATION OIT

PRIOR TO INSTALLATION AND CABLING TERMINATION.

D. PROVIDE BLANKING PANELS FOR ALL UNUSED RACK SPACE.

E. RACKS SHALL BE 30" CHANNEL STYLE, 45RU, WHITE.

F. EACH RACK SHALL INCLUDE A FULL HEIGHT FRONT/REAR 6" VERTICAL CABLE MANAGER ON EACH SIDE. TWO RACKS SHALL INCLUDE A

SINGLE CABLE MANAGER BETWEEN RACKS.

PLAN NOTES

1. RACK MOUNTED FIBER TERMINATION CASSETTE FOR DATA, WITH LC BULKHEADS. LEVITON OPT-X UHDX.

2. 1RU FLAT BLANKING PANELS. PROVIDE QUANTITY IN EACH RACK AS REQUIRED TO FILL ALL UNUSED RACK SPACES.

3. 1-4" CONDUIT WITH NYLON BUSHING INTO ROOM TR 102.

4. 24" x 1.5" VERTICALLY MOUNTED LADDER RACK, FIBER SECURED WITH VELCRO TIE WRAP.

5. CATEGORY 6A, 48 PORT, 1RU HIGH DENSITY ANGLED PATCH PANEL FOR PROPOSED DATA STATION CABLING. PANELS TO HAVE REAR CABLE MANAGERS AND ANGLED PANEL COVERS, LEVITON e2XHD SERIES, BLACK.

6. 1RU, HORIZONTAL, FRONT/REAR, CABLE MANAGEMENT PANEL.

7. NETWORK EDGE SWITCH BY VA.

8. 2RU, HORIZONTAL, FRONT/REAR, CABLE MANAGEMENT PANEL.

9. L21-20P SIDE A REQUIRES A 208 V, 20 A, THREE-PHASE CIRCUIT, TERMINATING IN A NEMA L21-20R LOCKING RECEPTACLE. L21-20P SIDE B REQUIRES A 208 V, 20 A, THREE-PHASE CIRCUIT, TERMINATING IN A NEMA L21-20R LOCKING RECEPTACLE.

10. 5KW, 208V UPS. PROVIDE IN TR RACK.

11. ZONE PDU 20 A, 3-PHASE ZONE PDU BASE UNIT. SIDE A, REQUIRES A 208V, 20A, 3 PHASE CIRCUIT, TERMINATING IN A NEMA L21-20R LOCKING RECEPTACLE. L21-20P SIDE B REQUIRES A 208 V, 20 A THREE-PHASE CIRCUIT, TERMINATING IN A NEMA L21-20R LOCKING

RECEPTACLE.

12. RACK MOUNTED TELECOMMUNICATIONS EQUIPMENT GROUND BAR (RBB) PRE-DRILLED FOR 2-HOLE LUGS. ALL EQUIPMENT WITHIN RACK TO BE BONDED TO BAR UTILIZING # 6awg BONDING CONDUCTORS. BOND BAR TO SBB WITHIN EACH TR. PROVIDE AT TOP OF

RACK IN TR.

13. 5-4" PVC CONDUITS UP THOUGH FLOOR.

14. PRIMARY BONDING BAR (PBB) ALL CONNECTIONS SHALL BE MADE WITH DOUBLE-BOLTED, COMPRESSION STYLE GROUNDING LUGS.

15. 8' HIGH x 4' WIDE x 3/4" THICK FIRE RATED AC GRADE PLYWOOD BACKBOARD, MOUNTED VERTICALLY 6" AFF AND RUNNING FULL WIDTH OF WALL. PLYWOOD SHALL BE PAINTED WITH TWO COATS ON ALL SIDES WITH A FIRE RETARDANT PAINT, LEAVING ONE FIRE RATING

STAMP VISIBLE AND UNPAINTED.

16. BAS FODP TERMINATION PANEL.

17. PROVIDE BOGAN AMPLIFIER MODEL NQ-A2060-G2 AND SHELF.

18. TEBC CONDUCTOR SIZE TO BE MINIMUM # 6 AWG PER TIA-607 CONDUCTOR SIZE BASED ON LENGTH / DISTANCE.

19. 12"x1.5" LADDER CABLE TRAY.

20. PROVIDE FIRE - AND/OR SMOKE-RATED SEALANT AROUND ALL CONDUIT AND SLEEVE PENETRATIONS ENTERING THE TELECOMMUNICATIONS ROOM. ENSURE ALL SEALS MEET THE REQUIRED FIRESTOP RATING FOR THE ASSEMBLY PENETRATED AND ARE

INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS.

21. PROVIDE PHYSICAL ACCESS CONTROL PANEL.

22. DOOR LOCKING HARDWARE 24 VOLT DC POWER SUPPLY.

23. FIBER MEDIA CONVERSION FROM GATE 1, GATE 2, AND PTZ SSTV ON LIGHT POLE.

24. RACK MOUNTED FIBER TERMINATION PANEL FOR FIRE ALARM, WITH LC BULKHEADS. LEVITON OPT-X UHDX.

25. DATA JACK FOR WALL MOUNTED CAMERA.

26. PROVIDE PATHWAYS AT THE MEZZANINE LEVEL FOR CONDUITS ENTERING TR-102. ROUTE CONDUITS TO TERMINATE ABOVE THE LADDER RACK AND COORDINATE ENTRY LOCATIONS WITH EQUIPMENT LAYOUT. BOND AND GROUND ALL CONDUITS TO THE SBB IN THE TR. SEAL ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES WITH APPROVED FIRESTOP SYSTEMS TO MAINTAIN THE RATING.

27. FIBER MEDIA CONVERSION FOR POLE MOUNTED CAMERA.

28. SHELF.

4-11/16" BOX

1.25" BUSHED

CONDUIT

PHONE

4-11/16" BOX

1.25" BUSHED

CONDUIT

DATA DATA

• ONE (1) BLUE CAT 6A JACK MODULE

• ONE (1) BLUE CAT 6A CABLE

• TWO (2) BLUE CAT 6A JACK MODULE

• TWO (2) BLUE CAT 6A CABLE

4-11/16" BOX

1.25" BUSHED

CONDUIT

DATA

• ONE (1) BLUE CAT 6A JACK MODULE

• ONE (1) BLUE CAT 6A CABLE

• ONE (1) RG-6 CABLE

• ONE (1) RG-6 F-TYPE CONNECTOR

R

DATA DATA

4-11/16" BOX

1.25" BUSHED

CONDUIT

DATA

• THREE (3) BLUE CAT 6A JACK MODULES

• THREE (3) BLUE CAT 6A CABLES

W 2D 3D

2-POSITION SURFACE BOX "BISCUIT":

• TWO (2) MODULAR 8-POSITION JACK "GREEN"

• TWO (2) CATEGORY 6A UTP CABLES "GREEN"

FURNISH AND TERMINATE CABLES WITH A 10 FT. SLACK COIL AT EACH

LOCATION.

10 FT. SLACK COIL

WIRELESS DEVICE

ACCESS POINT (AP)

(LAY-IN CEILING)

AP

X

1 2

3 4

XX-XXX-XX

XX-TR-XXX

FACEPLATE ID

XX XXX XX

FACEPLATE NUMBER IN ROOM

ROOM NUMBER

BUILDING/FLOOR IDENTIFIER

TELECOMMUNICATIONS ROOM ID

XX XX-XXXX

TR NUMBER ON FLOOR

BUILDING/FLOOR IDENTIFIER

NOTES:

1. EACH "TO" SHALL BE LABELED AS SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE

FOR INSTALLING A MACHINE-PRINTED LABEL WITH THE CORRECT FACEPLATE ID NUMBER AND TR ID.

2. CABLE JACKET COLOR SHALL MATCH THE JACK COLOR.

TELECOMMUNICATIONS OUTLET LABELING SCHEME

BASIS OF DESIGN FOR DATA CABLING

DATA

4-11/16" BOX

1.25" BUSHED

CONDUIT

• ONE (1) BLUE CAT 6A JACK MODULE

• ONE (1) BLUE CAT 6A CABLE

1D

CAT 6A CABLES AND COAXCAT 6A CABLESCAT 6A CABLESCAT 6A CABLECAT 6A CABLE

BLANK

TR 102

CABLE TRAY

P

X" AFF

EMT CONDUIT SLEEVE

A. PROVIDE CONDUIT FOR ALL LOW-VOLTAGE CABLING UNLESS

OTHERWISE NOTED. CONDUIT SHALL NOT BE REQUIRED WITHIN THE

CONTROL ROOM, EXCEPT FROM DEVICE JUNCTION BOX TO A STUB-

OUT ABOVE CEILING; UTILIZE J-HOOK(S) TO SLEEVE ENTERING TR 102.

DETAIL NOTES

12" MIN. BOTH ENDS

FIRE SEAL WITH APPROVED

CAULK OR PUTTY BY CABLE

INSTALLER

FIRE SEAL BY CONDUIT INSTALLER

EMT CONDUIT WITH BUSHED ENDS

APPROVED CATEGORY-RATED

CABLE

FIRE SEAL WITH APPROVED

CAULK OR PUTTY BY CABLE

INSTALLER

FILL CAVITY WITH ROCK-WOOL

FIRE SEAL WITH APPROVED

CAULK OR PUTTY BY CABLE

INSTALLER

6"

2"

1' -3

FIRE SEAL BY CONDUIT INSTALLER

EMT CONDUIT WITH

BUSHED ENDS

APPROVED

CATEGORY-RATED

CABLE

FIRE SEAL WITH APPROVED

CAULK OR PUTTY BY CABLE

INSTALLER

FILL CAVITY WITH

ROCK-WOOL

DETAIL NOTES:

A. DETAILS SHOWN IS FOR GUIDANCE ONLY. BRACING

SHALL BE IN ACCORDANCE WITH MANUFACTURER'S

RECOMMENDATION AND ANCHORS TO BE SEISMICALLY

PRE-QUALIFIED PER ACI 355.2.

B. INSTALL CABLE TRAY AND FITTINGS STRICTLY IN

ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

CABLE TRAY

GROUND CLAMP

LADDER TRAY

GROUNDING BUSHING

#6 AWG GROUND WIRE

C. INSTALL SHALL NOT EXCEED BICSI STANDARDS FOR CABLE BEND RADIUS.

CONDUIT CONNECTOR GROUNDING

BUSHING

EXPLODED VIEW

LADDER TYPE

CABLE TRAY

DETAIL NOTES:

A. DETAILS SHOWN IS FOR GUIDANCE ONLY. BRACING

SHALL BE IN ACCORDANCE WITH MANUFACTURER'S

RECOMMENDATION AND ANCHORS TO BE SEISMICALLY

PRE-QUALIFIED PER ACI 355.2.

B. INSTALL CABLE TRAY AND FITTINGS STRICTLY IN

ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

9/16" D

6/32" D (TYP. OF 6)

1-1/8" O.C.

9/32" D (TYP. OF 12)

1-1/8" O.C.

DETAIL NOTES

1. 4"x1/4"x12" MIN. LENGTH GROUNDING BAR #A-6163 OR EQUAL

ACTUAL LENGTH REQUIRED BY QUANTITY OF GROUND

CONNECTIONS.

2. WALL MOUNTING BRACKET #A-6056 OR EQUAL.

3. INSULATORS #3061-4 OR EQUAL.

4. 5/8-11X1 H.H.C.S. #3012-1 OR EQUAL.

5. 5/8" LOCKWASHER.

BOGEN

AMPLIFIER

MODEL NQ-A2060-G2

IN ROOM TR 102

120VAC

TYPICAL

P

SP SP NEXT

SPEAKER IN

LINE

A. REFER TO DRAWINGS FOR QUANTITY AND TYPE

OF SPEAKER.

B. VoIP PAGING AMPLIFIER.

GENERAL NOTES

14AWG/2C FOR AUDIO

FROM BUILDING #37

PAGING SYSTEM

1D

THREADED ROD SUPPORT,

TYPICAL

INDEPENDENTLY SUPPORTED

J-HOOK TREE ASSEMBLY, SIZE

& QUANTITY AS REQUIRED TO

SUPPORT CABLE BUNDLES

4 FT. M

AX

SEPARATION

J-HOOK TREE ASSEMBLY,

SUPPORTED BY CABLE TRAY

INDEPENDENTLY SUPPORTED

SINGLE J-HOOK ASSEMBLY, SIZE

AS REQUIRED TO SUPPORT

CABLE BUNDLE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /M a ri o n I

L V

A

N e w E n e rg y C e n te r/

-0

-M

E P

-C e n tr a l.

rv t

/5 /2

:2

This is the start of the file's text. The full file is on GovTribe.