631-21-011 Bid Drawings_Part3.pdf

PDF 11 MB Posted

Attached to
Z2DZ-- 631-21-011 Modernize, Replace, or Install Elevators in 8 Buildings Federal contract opportunity
Solicitation number
36C24123B0011
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

This document outlines a federal contract opportunity to modernize, replace, or install elevators in eight buildings for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1. Solicitation number 36C24123B0011 requests bids to replace elevators at various VA medical center locations, with a response due date of April 30, 2022. The opportunity type is listed as a solicitation. The related file provides bid drawings in PDF format with a file size of 11MB to assist contractors in preparing responses for the elevator modernization and installation work across eight VA buildings. Relevant details include the federal agency involved, general scope of work required, response deadline, and file to aid bidding on the opportunity.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DZ-- 631-21-011 Modernize, Replace, or Install Elevators in 8 Buildings, newest first.
File Type Posted
36C24123B0011 0002.docx DOCX document
36C24123B0011 0001.docx DOCX document
631-21-011 Modernize Elevators RFI Responses 20230802.docx DOCX document
S02_WD MA 20230003 07 28 2023.pdf PDF
S04_Site Visit Sign-In Sheet_631-21-011.pdf PDF
VA Leeds Building 25 Geo Report 05-17-22.pdf PDF
631-21-011 Bid Drawings_Part2.pdf PDF
631-21-011-Bid Specifications.pdf PDF
36C24123B0011.docx DOCX document
S02_WD MA 20230003 06162023.pdf PDF
631-21-011 Bid Drawings_Part1.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

2:

:4

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

W-G-002

MEADOW (BUILDING 2) EXISTING

PHOTOS

2 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

DocuSign Envelope ID: 541ADAB3-2504-4B07-BAA0-A19CCA635BA3

6/28/2023

DN

UP

NEW WALL

NEW DOOR

NEW WINDOW

NEW WORK LEGEND

ELEVATOR

EQUIP

RM

UP

W-A-400 _____ 3

W-A-400

ELEVATOR

PIT

P2

FD

TC

102A

DN

W-A-400 _____ 3

W-A-400

ELEVATOR

P2

HK

CORRIDOR

ELEVATOR

P2

EXISTING WALL TO REMAIN

EXISTING DOOR TO REMAIN

TEMPORARY DOOR

TEMPORARY WALL

DEMOLISH WALL

DEMOLISH DOOR

DEMOLISH WINDOW

EXISTING WINDOW TO REMAIN

DEMOLITION LEGEND

TEMPORARY WALL

TEMPORARY DOOR

TC

102A

ELEVATOR

P2

CORRIDOR

ROOM

HK

203ROOM

ROOM

ELEVATOR

P2

ELEVATOR

EQUIP

RM

ELEVATOR

PIT

P2

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

2:

:2

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

W-A-100

MEADOW (BUILDING 2) ELEVATOR

FLOOR PLANS & DETAILS

3 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

NORTH

0 4 8 16

1 NEW ELEVATOR CAB FINISHES.

2 NEW ELEVATOR PANEL/CONTROLS.

3 NEW ELEVATOR DOOR.

4 PROVIDE NEW CODE COMPLIANT PIT LADDER. SEE

SHEET G-006 FOR PIT LADDER DETAILS

5 CARD READER WILL BE PLACED ON THE DOOR

FRAME.

6 NEW 90 MIN RATED DOOR AND FRAME, REFER TO

DOOR SCHEDULE FOR MORE INFORMATION.

7 PROVIDE WALL BRACKET AND SNOW HOOD COVER

FOR NEW MINI-SPLIT CONDENSING UNIT. SEE MECH.

DWGS FOR MORE INFORMATION

8 WALL MOUNTED MINI-SPLIT UNIT AND CONDENSATE

PUMP. DO NOT PLACE DIRECTLY OVER ANY

PROPOSED OR EXIST. ELEVATOR EQUIPMENT THAT

IS IN THE ROOM

9 GC TO VERIFY IF EXISTING FIRE EXTINGUISHER IS

STILL CODE COMPLIANT. IF IT IS NOT CODE

COMPLIANT, THE GC WILL REPLACE THE EXISTING

FIRE EXTINGUISHER WITH A NEW CODE COMPLIANT

EXTINGUISHER AND BRACKET.

10 NEW CELLAR DOOR ABOVE

11 NEW CELLAR DOOR, REFER TO DOOR SCHEDULE

FOR MORE INFORMATION.

12 PROVIDE INTERIOR CONTROL PANEL.

13 PROVIDE NEW ELEVATOR HOISTWAY DOOR.

14 OIL INTERCEPTOR. SEE DETAIL 3/PF501 FOR MORE

INFORMATION.

15 ELEVATOR SUMP PUMP. SEE DETAIL 3/PF501 FOR

MORE INFORMATION.

Scale: 1/4" = 1'-0"

ELEVATOR PIT & ELEV. EQUIP. ROOM NEW WORK FLOOR

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR NEW WORK PLAN

Scale: 1/4" = 1'-0"

SECOND FLOOR NEW WORK PLAN

NORTH

0 2 4 8

NORTH

0 2 4 8

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

NORTH

0 4 8 16

NORTH

0 2 4 8

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

FIRST FLOOR DEMOLITION FLOOR PLAN

Scale: 1/4" = 1'-0"

SECOND FLOOR DEMOLITION PLAN

Scale: 1/4" = 1'-0"

ELEVATOR PIT & ELEV. EQUIP. ROOM DEMOLITION PLAN

1 DEMOLISH EXISTING ELEVATOR CAB INTERIOR

FINISHES

2 DEMOLISH EXISTING ELEVATOR PANEL/CONTROLS

3 DEMOLISH EXISTING ELEVATOR CAB DOOR

4 DEMOLISH EXISTING PIT LADDER

5 DEMOLISH EXISTING DOOR AND HM FRAME

6 REPAIR AND REPAINT STAIRS AND STAIR WALLS

7 REPLACE EXISTING METAL CELLAR DOORS

8 REMOVE AND STORE EXISTING METAL FLOOD STOP

BRACING. REPLACE AFTER FLOOR REPAINTING.

9 DEMOLISH EXISTING ELEVATOR HOISTWAY DOOR

10 TRENCH OUT ELEVATOR PIT FOR NEW EQUIPMENT.

SEE PLUMBING DWGS FOR MORE INFORMATION.

A. SEE SHEET G-005 FOR GENERAL NOTES.

B. SEE SHEET W-A-400 FOR ELEVATOR P1 CAB

PLANS AND INTERIOR ELEVATIONS.

C. PATCH AND REPAIR ALL HOLES TO BE SEALED

WITH FIRESTOPPING.

D. PATCH, REPAIR, AND PAINT ALL GYPSUM BOARD

DAMAGED OR ALTERED DUE TO NEW ELEVATOR

WORK. INCLUDING BUT NOT LIMITED TO

REPLACING JAMB WORK AND CONTROL DEVICE

AND LANTERN CHANGE OUT WORK.

E. SEE SPECIFICATION SECTION 14 20 10 FOR

EQUIPMENT SCHEDULES AND ADDITIONAL

INFORMATION.

F. CEILING CONTRACTOR TO MEASURE EACH

CEILING AREA AND ESTABLISH A CEILING LAYOUT

TO BALANCE BORDER WIDTHS AT OPPOSITE

EDGES OF EACH ROOM. AVOID USE OF LESS-

THAN 6" TILES.

G. EXIST. METAL FLOOR FLOOD STOP BARS SHALL

BE REMOVED. THE EQUIP. RM. FLOOR SHALL BE

PAINTED. THE FLOOR FLOOD STOP BARS SHALL

BE REINSTALLED.

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

CR

TOP OF CAB

8' -0

PROVIDE NEW MAIN

CAR OPERATING

PANEL IN THE CAR

ENCLOSURE ON THE

FRONT RETURN

PANEL. CONTRACTOR

TO VERIFY LOCATION

PER CAB INTERIOR.

SEE ELEVATOR

SPECIFICATIONS

PROVIDE CAB WITH NEW

TWO-SPEED SIDE

HORIZONTAL SLIDING

HOISTWAY DOORS .

PROVIDE CAR ENCLOSURE

WITH NEW S.S. PANELS

ABOVE ELEVATOR DOOR.

COORDINATE

EMERGENCY EXIT

HATCH WITH CAB

CEILING

PROVIDE CCTV

CAMERA INSIDE OF

THE CAR. SEE

ELECTRICAL SHEETS.

PROVIDE (6) LED

ILLUMINATED CAR

LIGHT FIXTURES

ABOVE THE CEILING.

MAINTAIN A MINIMUM

LIGHT LEVEL OF 50-

FOOT CANDLES AT

(36") ABOVE THE

FINISHED FLOOR.

PROVIDE S.S.

HANGING CEILING

FRAME. CONSTRUCT

FRAME OF .125" X

1.50" X 1.50" "T" AND

"L" SECTIONS.

1"

EQ

1/ 2"

EQ

1/

2"

EQ

1"

SE

E

SC

H

ED

U

LE

SEE SCHEDULE

1" EQ EQ 1"1/2"

8' -0

PROVIDE CAR

ENCLOSURE WITH

NEW S.S. CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH NEW

HANDRAIL @ CENTERLINE OF 30" AND

42" ABOVE THE CAR FLOOR. MATCH

EXIST. SPACING OF HANDRAIL FROM

CAB WALL. CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL BE

REMOVABLE FROM THE INSIDE OF THE

CAR ENCLOSURE. LOCATE HANDRAILS

1-1/2" FROM CAB WALL. PROVIDE 1-1/2"

S.S. ROUND HANDRAILS WITH THE ENDS

AT THE ENTRANCE TURNED BACK TO

THE WALL.

PROVIDE NEW CAR

ENCLOSURE. FINAL PANEL

DESIGN TO BE APPROVED BY

VA INTERIOR DESIGNER

1' -0

2'

-6

4"

1" EQ 1/2" EQ 1/2" EQ

8"

PROVIDE NEW 8" TALL CRASH RAIL

@12" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

SEE SCHEDULE

7' -0

3' -6

CALL BUTTON.

HOISTWAY DOORS

TO BE REPLACED -

SEE ELEVATOR

SPECIFICATIONS.

COMBINATION

HALL LANTERNS

AND ELEV CALL

BUTTON PLATES

TO BE REPLACED

BACK BOXES TO

REMAIN.

RECLAD EXISTING

STAINLESS STEEL

ENTRANCE FRAME,

AND TOP HEADER.

EMERGENCY

KEYWAY PLATE TO

BE REPLACED

8' -0

TOP OF CAB

1' -0

2'

-6

4"

1" EQ 1/2" EQ 1"

8"

PROVIDE CAR

ENCLOSURE WITH

NEW S.S. CEILING

PROVIDE CAR ENCLOSURE WITH

NEW HANDRAIL @ CENTERLINE OF

30" AND 42" ABOVE THE CAR

FLOOR. MATCH EXIST. SPACING OF

HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL BE

REMOVABLE FROM THE INSIDE OF

THE CAR ENCLOSURE. LOCATE

HANDRAILS 1-1/2" FROM CAB WALL.

PROVIDE 1-1/2" S.S. ROUND

HANDRAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

PROVIDE NEW CAR

ENCLOSURE. FINAL

PANEL DESIGN TO BE

APPROVED BY VA

INTERIOR DESIGNER

PROVIDE NEW 8" TALL CRASH RAIL

@12" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

SEE SCHEDULE

PASSENGER ELEVATOR CAB SIZE SCHEDULE

ELEVATOR WIDTH DEPTH

P2 62" 92"

RATED LOAD

4,000 (lbs)

5' -2

7'-8"

7' -4

9'-4"

W-A-400 26

PROVIDE NEW CAR

ENCLOSURE WITH NEW

FLOORING.

NEW SECURITY

CAMERA

ELEVATOR

P2

ENTRANCE FRAME TYPE:

1. SWEEP JAMB AT EACH LEVEL OF THE

ELEVATOR ENTRANCE.

2. REFER TO SHEET G-006 FOR JAMB AND HEAD

DETAIL

F

SE

E

SC

H

ED

U

LE

SCHEDULE

SEE

F-1

2" 2"

SCHEDULE

SEE

SE

E

SC

H

ED

U

LE

2"

DOOR HARDWARE NOTES:

1. PROVIDE 90 MIN RATED H.M. FRAME IN EXISTING OPENING. PROVIDE RATING LABEL FOR DOOR AND FRAME.

2. PROVIDE CARD READER/PACS DEVICE AT NEW DOOR OPENING.

3. FBC APPROVED HARDWARE TO BE USED ON NEW DOOR IN THIS OPENING.

4. COORDINATE HARDWARE REQUIREMENTS WITH NEW FRAME. VERIFY LOCK FUNCTIONS AND HARDWARE COMPATIBILITY PRIOR TO ORDERING ANY HARDWARE.

5. PROVIDE NEW SECURITY CAMERA AT CORRIDOR SIDE OF DOOR OPENING.

6. SEE HARDWARE SETS IN SPECIFICATION 08 71 00 FOR DOOR COMPONENTS.

7. PROVIDE WELDED FRAMES PER VA REQUIREMENTS, SEE SPECIFICATIONS FOR MORE INFORMATION.

DOOR REMARKS:

1. PROVIDE ELECTRIC WIRING TO CARD READER AND ELECTRIC STRIKE. SEE ELECTRICAL DWGS. FOR MORE INFORMATION.

2. REPLACE EXISTING CELLAR DOOR (SEE 3/W-A-400). FIRST FLOOR

0' - 0"

1' -1

0"

V.I.F.5'-4" +/-

ALL FASTENERS AND CONNECTIONS

TO EITHER BRICK WALLS OR

CONCRETE SLAB SHALL BE GALV.

PER DOOR MANUFACTURER

PROVIDE GALV. REGLET

FLASHING AND SEALANT IN

MASONRY JOINT, ALONG WITH

PERIMETER OF MASONRY WALL

ATTACHMENT

EXIST. BRICK MASONRY WALL

FIELD VERIFY EXIST. DOOR TO

ENSURE THAT NEW DOOR WILL

FIT OVER EXIST. STAIRS

NEW BASEMENT DOOR

B.O.D. BILCO BASEMENT DOOR

SIZE: B

COLOR: BRICK

DIM: 51" W X 64" L X 22" H

REMOVE EXIST. BASEMENT

DOOR AND STEEL HOOD

EXIST. CONCRETE BASE &

STAIRS TO BE POWERWASHED

AND CLEANED

STRIP PAINT FROM EXIST.

HANDRAILS AND RE-PAINT

HANDRAILS & WALL

ATTACHMENTS

PROVIDE NEW GALVANIZED

METAL HOOD WITH 12" X 12"

VENTILATION LOUVER. PAINT

HOOD TO MATCH BASEMENT

DOOR COLOR

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

2:

:2

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

W-A-400

MEADOW (BUILDING 2) ELEVATOR

BUILDING SECTION & INTERIOR CAB

ELEVATIONS

4 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

Scale: 3/4" = 1'-0"

CAB INTERIOR - FRONT ELEVATION - MEADOW

Scale: No Scale

ELEVATOR CAB - CEILING PLAN - MEADOW

Scale: 3/4" = 1'-0"

CAB INTERIOR - SIDE ELEVATION - MEADOW

Scale: No Scale

TYPICAL PASSENGER CAB - EXTERIOR ELEVATION -

MEADOW

Scale: 3/4" = 1'-0"

CAB INTERIOR - REAR ELEVATION - MEADOW

Scale: 3/4" = 1'-0"

ELEVATOR CAB - FLOOR PLAN - MEADOW

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

Scale: 1/2" = 1'-0"

MEADOW EQUIPMENT ROOM DOOR TYPE

Scale: 1/2" = 1'-0"

MEADOW EQUIPMENT ROOM FRAME TYPE

DOOR SCHEDULE

ROOM NAME

DOOR DOOR DOOR FRAME

LBL

HDWR

SET REMARKSNO. WIDTH HEIGHT THICK MAT'L FINISH ELEV MAT'L FINISH ELEV

ELEVATOR

EQUIP RM

003 3' - 0" 7' - 0" 1 3/4" MTL PNT F HM PNT F-1 90 MIN. 1.0 1

ELEVATOR

EQUIP RM

003A 4' - 0" 4' - 2" - MTL PNT - HM PNT - - 2

ROOM FINISH SCHEDULE

ROOM NO. NAME FLOOR BASE

WALLS

REMARKSEAST NORTH SOUTH WEST

003 ELEVATOR EQUIP

RM

EPF-1 RB-1 P-4 P-4 P-4 P-4 PAINT EXTERIOR TO MATCH

EXISTING BUILDING,FLOOD STOPS

TO BE REMOVED, FLOOR TO

RECIEVE EPOXY PAINT, FLOOD

STOP TO BE RE-INSTALLED

Scale: 1/2" = 1'-0"

CELLAR DOOR SECTION

POSITION INDICATORS IN HALLWAY/LOBBY SHOULD

DISPLAY "OUT OF SERVICE", FOR FIRE SERVICE,

INDEPENDENT SERVICE, ELEVATOR INSPECTION, ETC.

ROOM

542SF

ELEVATOR PIT

P2

ELEVATOR EQUIP RM

ROOM

542SF

ELEVATOR PIT

P2

ELEVATOR EQUIP RM

2-SP-1

2-SP-2

1 1/2" PD

3" PD

4" SAN

1 1/2" PD

FD-B

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

5:

:1

PM

C :\U se rs

\s ge or ge

\D oc um en ts \R ev it

Fi le s\ R ev it

\M _2

1-

9_ Le ed s-

In st al l E le v_ sp ge or ge

.rv t

W-PF101

MEADOW (BUILDING 2) PLUMBING AND

FIRE SUPPRESSION PLAN

1 1AV

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

SPG

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1 PROVIDE NEW SUMP PUMP IN ELEVATOR

MACHINE ROOM. CONNECT TO EXISTING DRAIN

PIPING.

2 TRENCH OUT ELEVATOR PIT FOR NEW SUMP

PUMP, OIL INTERCEPTOR, AND FLOOR DRAIN IN

ELEVATOR PIT. COORDINATE EXACT

LOCATIONS WITH ELEVATOR STRUCTURAL

SUPPORTS.

3 ROUTE PUMP DISCHARGE TO CRAWL SPACE,

DISCHARGE TO TOP OF EXISTING 4" SANITARY

PIPE.

4 PROVIDE QUICK RESPONSE SPRINKLER HEADS

IN ELEVATOR PIT. EXTEND SPRINKLER PIPE

FROM MACHINE ROOM.

5 SLEEVE AND FIRE SEAL PIPE PENETRATION

THROUGH ELEVATOR SHAFT WALL.

6 ROUTE SEPARATE 2" VENTS FROM OIL

INTERCEPTOR AND SUMP PUMP UP TO 18'

ABOVE PIT FLOOR.

Scale: 1/4" = 1'-0"

BASEMENT FLOOR PLUMBING AND FIRE SUPPRESSION

DEMOLITION PLAN

Scale: 1/4" = 1'-0"

BASEMENT FLOOR PLUMBING AND FIRE SUPPRESSION

NEW WORK PLAN

1 DEMOLISH EXISTING SUMP PUMP IN ELEVATOR

MACHINE ROOM. DISCONNECT FROM EXISTING

PUMP DISCHARGE PIPING, CAP AND PREPARE

FOR RECONNECTION.

NORTH

0 4 8 16

NORTH

0 4 8 16

A. SLEEVE ALL PENETRATIONS. FIRESTOP AND

SEAL WATER TIGHT.

B. REUSE EXISTING FIRE SUPPRESSION MAINS

WHERE POSSIBLE. PROVIDE NEW BRANCH

PIPNG AS REQUIRED.

C. EXISTING FIRE AND SMOKE ZONES SHALL BE

MAINTAINED.

Scale: 12" = 1'-0"

CRAWLSPACE PLUMBING PLAN 2

NORTH

0 4 8 16

ROOM

542SF

ELEVATOR PIT

P2

ELEVATOR EQUIP RM

2-UH-1 2-SS-1

2-CU-1

T 4 S

RLRL3/4" D

ROOM

542SF

ELEVATOR PIT

P2

ELEVATOR EQUIP RM

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

5:

:1

PM

C :\U se rs

\s ge or ge

\D oc um en ts \R ev it

Fi le s\ R ev it

\M _2

1-

9_ Le ed s-

In st al l E le v_ sp ge or ge

.rv t

W-M-101

MEADOW (BUILDING 2) MECHANICAL

PLAN

1 1AV

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

SPG

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/4" = 1'-0"

BASEMENT FLOOR MECHANICAL NEW WORK PLAN

A. COORDINATE ALL DEMOLITION WORK WITH THE

GENERAL CONTRACTOR, OTHER TRADES AND

THE COR TO MINIMIZE DISRUPTION OF AREAS

OUTSIDE OF THE PROJECT LIMITS OF WORK.

B. ALL DEMOLISHED EQUIPMENT SHALL BECOME

THE PROPERTY OF THE CONTRACTOR AND

SHALL BE DISPOSED OF IN ACCORDANCE WITH

VAPHS REQUIREMENTS AND ENVIRONMENTAL

REGULATIONS.

C. CONTRACTOR TO FIELD VERIFY ALL

CONDITIONS. PRESERVE EXISTING DUCTWORK,

PIPING OR EQUIPMENT THAT IS NOT INDICATED

FOR DEMOLITION OR IS DISCOVERED IN THE

DEMOLITION PROCESS.

NORTH

0 4 8 16

1 PROVIDE NEW DUCTLESS SPLIT AND OUTDOOR

CONDENSING UNIT. ROUTE REFRIGERANT

LIQUID AND SUCTION PIPING TO OUTDOOR UNIT

ACCORDING TO MANUFACTURER'S

RECOMMENDATIONS.

2 PROVIDE NEW ELECTRIC UNIT HEATER.

3 PROVIDE MANUFACTURER'S CONDENSATE

PUMP. ROUTE CONDENSATE DRAIN TO

EXTERIOR WALL, DISCHARGE ON NEW SPLASH

BLOCK ON GRADE.

4 PROVIDE NEW THERMOSTAT FOR MINI-SPLIT

SYSTEM AND NEW CENTRAK TEMPERATURE

SENSOR. CONFIGURE TO EXISTING SYSTEM.

5 MOUNT WITH WALL BRACKET PER DETAIL

6/M-501.

Scale: 1/4" = 1'-0"

BASEMENT FLOOR MECHANICAL DEMOLITION PLAN

NORTH

0 4 8 16 1 DEMOLISH EXISTING UNIT HEATER.

GF

I

T

CR

ES

DC

RX

E

GF

I

T

GFI

WP E

ELEVATOR

EQUIP

RM

ELEVATOR

PIT

P2

ROOM

542SF

EC

B

G H I J K

PANEL '2-B1'

Ex. UH

2-UH-1

'2-B1'- 14,16

'E1EB-2'- 7

'E1EB-2'- 8

'E1EB-2'- 15

ELEVATOR

EQUIP

RM

ELEVATOR

PIT

P2

ROOM

542SF EXISTING

PANEL '2-B1'

EC

B

G H I J K

ELEVATOR

EQUIP

RM

003ELEVATOR

PIT

P2

ROOM

542SF

PANEL '2-B1'

EC

B

B1

B1 EM

G H I J K

ROOM

CORRIDOR

-ELEVATOR

P2

TC

102A

ROOM

ROOM

ROOM

G H I J K

'2-B1'- 15 '2-B1'- 17

2-CU-1

ROOM

ROOM

ROOM

CORRIDOR

ROOM

HK

G H I J K

ELEVATOR

P2

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

:5 7:

A

M C

:\U se rs \w re ed

\D oc um en ts \E

_2 1-

9_

Le ed s- In st al l E le v_ w re ed

R G

8R E.

rv t

W-E-101

MEADOW (BUILDING 2) FLOOR

ELECTRICAL PLANS

1 1AMM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JKM

1 CIRCUIT NEW LIGHTS AND SWITCH TO

EXISTING ROOM LIGHTING CIRCUIT.

2 EXISTING ELEVATOR CIRCUIT BREAKER TO

REMAIN TO POWER NEW ELEVATOR

CONTROLLER.

3 NEW 30A 2 POLE DISCONNECT FOR

ELEVATOR CAB LIGHTS.

4 CONNECT NEW CAMERAS TO EXISTING

CAMERA SYSTEM IN TR 115C.

5 CONNECT NEW CARD READER TO EXISTING

PACS IN TR 115C. MOUNT CARD READER IN

THE DOOR MULLION. PROGRAM CARD

READER PER VA.

6 EXISTING CCTV & PACS IN TR 115C SEE

4-G-001 FOR MORE INFO.

7 EXISTING CAMERA TO REMAIN.

8 DISCONNECT FOR ELEVATOR CAB LIGHTS.

CIRCUIT TO EXISTING CAB LIGHTS CIRCUIT.

9 NEW CAMERA TO BE INSTALLED IN

ELEVATOR CAB. CONNECT NEW CAMERAS

TO THE EXISTING CAMERA SYSTEM.

10 PROVIDE A NEW 1 POLE, 20A 5MA GFCI

BREAKER FOR THIS PUMP AND OIL LEVEL

SENSOR (IF APPLICABLE) AND CIRCUIT

USING 2-12 AWG, 1-12 AWG EG IN ¾”

CONDUIT.

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/4" = 1'-0"

ELEVATOR POWER PLAN

A. CONTRACTOR SHALL BE RESPONSIBLE FOR

TRACING AND IDENTIFYING ALL CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH, OR

TERMINATE IN THE AREA OF WORK. DEMOLISH

ALL CIRCUITS THAT ARE NO LONGER IN USE.

MAINTAIN CIRCUIT CONTINUITY TO ALL CIRCUITS

WHICH ARE NOT COMPLETELY REMOVED.

CONTRACOR RESPONSIBLE FOR LOCKOUT/TAG

OUT PROCEDURES OF LOADS FOR DEMOLITION.

B. CONTRACTOR SHALL DISCONNECT AND REMOVE

ELECTRICAL CONNECTION TO OUTLETS,

RECEPTACLES, HVAC EQUIPMENT AND OTHER

ELECTRICAL DEVICES. REMOVE CONDUCTORS

AND CONDUIT BACK TO PANELBOARD SERVICING

EQUIPMENT OR TO THE POINT WHERE OTHER

REMAINING LOADS ARE CONNECTED. MARK ANY

ABANDONED OVERCURRENT PROTECTION

DEVICE AS "SPARE (UNUSED)".

C. CONTRACTOR SHALL REMOVE ALL ELECTRICAL

CONDUIT, CABLE, WIRING DEVICE, JUNCTION

BOXES, FITTINGS, AND RELATED ITEMS FROM ALL

PORTIONS OF THE AREA OF WORK INCLUDING

WALL, CEILING, AND FLOORS. THIS SHALL BE FOR

ALL WALLS, EVEN WALLS NOT SUBJECT FOR

REMOVAL.

D. FOR ELECTRICAL CIRCUITS BEING DEMOLISHED,

REMOVE BOXES, CONDUIT AND CONDUCTORS

BACK TO SOURCE, INCLUDING THOSE

CONCEALED WITHIN WALLS, LEAVING NO

ABANDONED ITEMS.

E. WHERE CONDUIT IS REMOVED FROM AN

EXISTING RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING HOLE SHALL BE

PATCHED/REPAIRED TO MAINTAIN THE RATING

OF THE ASSEMBLY.

F. EACH PHASE OF THE CONSTRUCTION SHALL BE

PERFORMED WHILE LEAVING WORK AREAS OF

OTHER PHASES ACTIVE TO THE GREATEST

EXTENT POSSIBLE. NOTIFY COR IF ANY WORK IS

REQUIRED THAT WILL CROSS MULTIPLE PHASES

OF THE WORK AREA PRIOR TO PERFORMING THE

WORK.

G. ALL RECEPTACLE CONDUCTORS ARE 2-12 AWG,

1-12 AWG EG IN 3/4" CONDUIT MINIMUM UNLESS

NOTED OTHERWISE.

H. COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS OF ALL MECHANICAL AND

PLUMBING EQUIPMENT WITH MECHANICAL AND

PLUMBING CONTRACTORS.

I. COORDINATE EQUIPMENT WITH ARCHITECTURAL

& INTERIORS EQUIPMENT PLANS AND

SCHEDULES.

J. ELECTRICAL CONTRACTOR SHALL FOLLOW SITE

LOCK-OUT/TAG-OUT GUIDELINES TO DE-

ENERGIZE EQUIPMENT.

K. ALL RECEPTACLES SHALL HAVE THEIR SOURCE

PANEL AND CIRCUIT NUMBER INDICATED ON

THEIR FACEPLATE.

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

ELEVATOR DEMOLITION PLAN

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

ELEVATOR LIGHTING PLAN

NORTH

0 2 4 8

1 EXISTING SWITCH FOR CAB LIGHTS TO BE

REMOVED AND REPLACED WITH

DISCONNECT.

2 EXISTING ELEVATOR CIRCUIT BREAKER TO

REMAIN.

3 REPLACE EXISTING 100A MCB 208Y/120V

PANEL WITH NEW 30 CIRCUIT 100A MCB

208Y/120V PANEL. CONNECT TO EXISTING

FEEDERS.

4 DISCONNECT EXISTING LIGHTING CIRCUIT

AND REMOVE EXISTING LIGHTS. MAINTAIN

EXISTING CIRCUIT FOR REUSE WITH NEW

MACHINE ROOM LIGHTING.

PANEL '2-B1'

(TOTAL KVA) X 1000 = TOTAL AMPS

VOLTS X 1.732 0

PANEL / FEEDER (TOTAL KVA) 0.00

TOTAL DEMAND AMPERES PER PHASE 0 0 0

NOTE: ALL MOTOR CIRCUIT BREAKERS SHALL BE HACR

RATED.

TOTAL... 0.00 0.00 0.00 0.00 0.00 0.00

SIGN 0.00 0.00 0.00 125% 0.00 0.00 0.00

DEDICATED RECEPT 0.00 0.00 0.00 100% 0.00 0.00 0.00

NEUTRAL RATING 100% FIX. ELEC. SPACE HEAT 0.00 0.00 0.00 100% 0.00 0.00 0.00

BUS RATING 100A WATER HEATERS 0.00 0.00 0.00 125% 0.00 0.00 0.00

MCB RATING MCB ALL... 0.00 0.00 0.00 100% 0.00 0.00 0.00

MINIMUM AIC (K AMPS) 10

MOTORS AND...

LARGEST 0.00 0.00 0.00 125% 0.00 0.00 0.00

SERVICE ENTR. RATED YES X NO >10KVA@50% 0.00 0.00 0.00

MAIN CIRCUIT BREAKER YES X NO

GENERAL USE... 0.00 0.00 0.00 <=10 KVA@100% 0.00 0.00 0.00

ISOLATED GROUND BUS YES X NO GENERAL LIGHTING 0.00 0.00 0.00 125% 0.00 0.00 0.00

MOUNTING SURFACE A B C A B C

C/B TEMP. 75 C. RATING 120 208 V 3 PH 4... LOAD TYPE CONNECTED KVA NEC DEM

FACTOR

DEMAND KVA

0.00 0.00 0.00 TOTAL

SUB TOTAL 0.00 0.00 0.00 0.00 0.00 0.00 SUB TOTAL

SPARE --- --- 0.00 1P-20 29 30 1P-20 --- --- 0.00 SPARE

SPARE --- 0.00 --- 1P-20 27 28 1P-20 --- 0.00 --- SPARE

SPARE 0.00 --- --- 1P-20 25 26 1P-20 0.00 --- --- SPARE

SPARE --- --- 0.00 1P-20 23 24 1P-20 --- --- 0.00 SPARE

SPARE --- 0.00 --- 1P-20 21 22 1P-20 --- 0.00 --- SPARE

SPARE 0.00 --- --- 1P-20 19 20 1P-20 0.00 --- --- SPARE

SPEC --- --- 0.00 1P-20 17 18 1P-20 --- --- 0.00 SPARE

GFI RECEPTACLE --- 0.00 --- 1P-20 15 16 --- 0.00 ---

0.00 --- --- 13 14 2P-20 0.00 --- --- UNIT HEATER

SPACE

--- --- 0.00 2P-30 11 12 --- --- 0.00

SPACE --- 0.00 --- 1P-20 9 10 2P-15

--- 0.00 ---

SUMP PUMP (5mA GFCI)

ELEV WORKMAN LIGHT & RECEP 0.00 --- --- 1P-20 7 8 1P-20 0.00 --- --- EXHAUST FAN

EXHAUST FAN --- --- 0.00 1P-20 5 6 1P-20 --- --- 0.00 MACH ROOM LIGHTS & RECEP

PIT RECEPTACLE --- 0.00 --- 1P-20 3 4 1P-20 --- 0.00 --- CONTROL CIRCUIT

SHUNT TRIP BREAKER PWR 0.00 --- --- 1P-20 1 2 1P-20 0.00 --- --- LIGHTS - PIT & SHAFT

A B C A B C LOAD SERVED KVA / Phase CKT

BRKR

CKT

NO

NEUTRA

L

A B C

CKT

NO

CKT

BRKR

KVA / Phase LOAD SERVED

Scale: 1/4" = 1'-0"

FIRST FLOOR POWER PLAN

Scale: 1/4" = 1'-0"

SECOND FLOOR POWER PLAN

NORTH

0 2 4 8

NORTH

0 2 4 8

TR 115C

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

SD

HD

F

F

HD

SD

FS

SD

F

F

FA

C

P

F

SD

SDHD

ELEVATOR

EQUIP

RM

ELEVATOR

PIT

P2

ROOM

542SF

G H I J K

ELEVATOR

EQUIP

RM

ELEVATOR

PIT

P2

ROOM

542SF

G H I J K

15cd 1/2 W

G H I J K

ROOM

CORRIDOR

-ELEVATOR

P2

TC

102A

ROOM

ROOM

ROOM

G H I J K

ROOM

ROOM

ROOM

CORRIDOR

ROOM

HK

ELEVATOR

P2

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

:5 8:

A

M C

:\U se rs \w re ed

\D oc um en ts \E

_2 1-

9_

Le ed s- In st al l E le v_ w re ed

R G

8R E.

rv t

W-FA101

MEADOW (BUILDING 2) FIRE ALARM

PLANS

1 1AMM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

RSB

NORTH

0 4 8 16

1 REPLACE EXISTING ELEVATOR FIRE ALARM

RECALL MODULES WITH NEW AND CONNECT

TO EXISTING FIRE ALARM SYSTEM. SEE

DETAIL ON SHEET FA001 FOR MORE INFO.

2 PROVIDE NEW FIRE ALARM DEVICES AND

CONNECT TO EXISTING FIRE ALARM SYSTEM.

3 EXISTING FACP (NOTIFIER BY HONEYWELL TO

REMAIN).

4 EXISTING CAMERA TO REMAIN.

5 EXISTING FIRE ALARM DEVICES TO REMAIN.

6 PROVIDE SMOKE & HEAT DETECTORS ON TOP

OF THE HOIST.

Scale: 1/4" = 1'-0"

BASEMENT FLOOR FIRE ALARM DEMOLITION PLAN

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/4" = 1'-0"

BASEMENT FLOOR FIRE ALARM PLAN

NORTH

0 4 8 16

A. A CONTRACTOR SHALL BE RESPONSIBLE

FOR TRACING THE FIRE ALARM CONDUIT

AND WIRING.

B. EACH PHASE OF THE CONSTRUCTION SHALL

BE PREFORMED WHILE LEAVING WORK

AREAS OF OTHER PHASES ACTIVE TO THE

GREATEST EXTENT POSSIBLE. NOTIFY COR

IF ANY WORK IS REQUIRED THAT WILL

CROSS MULTIPLE PHASES OF THE WORK

AREA PRIOR TO PREFORMING THE WORK.

C. COORDINATE EQUIPMENT WITH

ARCHITECTURAL AND INTERIORS

EQUIPMENT PLANS AND SCHEDULES.

D. CONNECT NEW FIRE ALARM DEVICES TO THE

EXISTING FIRE ALARM PANEL.

1 EXISTING FIRE ALARM DEVICES TO BE

REPLACED WITH NEW.

Scale: 1/4" = 1'-0"

FIRST FLOOR FIRE ALARM DEMOLITION PLAN

Scale: 1/4" = 1'-0"

SECOND FLOOR FIRE ALARM PLAN

NORTH

0 2 4 8

NORTH

0 2 4 8

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS MATRIX OF PRECAUTIONS

FOR CONSTRUCTION AND RENOVATION

107108

105 106

135A

127A

118120122

TC

HK

TC

136A

UP

DN

UP

DN

UP

III/IVLOW Risk Group 1

Class III Note: Infection Control approval will be required when the Construction Activity and Risk Level indicate that

It is the Contractor's Responsibility to provide the following Infection Control Precautions depending upon the Area Class Designation

I

I

II

MEDIUM Risk Group 2 HIGH Risk Group 3 HIGHEST Risk Group 4 IV

IV

IV

III/IV

III/IV

III

III/IV

II

II

Patient Risk Group Table

Infection Control Matrix - Class of Precautions: Construction Project by Patient Risk

TYPE A

Construction Project Type

Major demolition and construction projects

Includes, but is not limited to:

- activities which require consecutive work shifts

- requires heavy demolition or removal of a complete cabling system

- new construction

Work that generates a moderate to high level of dust or requires demolition or removal of any fixed building components or assemblies

Includes, but is not limited to:

- sanding of walls for painting or wall covering

- removal of floor coverings, ceiling tiles and casework

- new wall construction

- minor duct work or electrical work above ceilings

- major cabling activities

- any activity which cannot be completed within a single work shift

Small scale, short duration activities which create minimal dust

Includes, but is not limited to:

- installation of telephone and computer cabling

- access to chase spaces

- cutting of walls or ceiling where dust migration can be controlled

Inspection and Non-Invasive Activities Includes, but is not limited to:

- removal of ceiling tiles for visual inspection limited to 1 tile to 50 square feet

- painting (but not sanding)

- wallcovering electrical trim work, minor plumbing, and activities which do not generate dust or require cutting of walls or access to ceilings other than for visual inspection

Type of Construction / Project Activity Table

Group 2 Medium Risk

Group 1 Low Risk

- Cardiology

- Echocardiography

- Endoscopy

- Nuclear Medicine

- Physical Therapy

- Radiology/MRI

- Respiratory Therapy

- Office areas

I

Patient Risk Group

TYPE D

TYPE C

TYPE B

TYPE A

Group 4 Highest Risk

Group 3 High Risk

- CCU

- Emergency Room

- Labor & Delivery

- Laboratories (specimen)

- Medical Units

- Newborn Nursery

- Outpatient Surgery

- Pediatrics

- Pharmacy

- Post Anesthesia Care Unit

- Surgical Units

- Any area caring for immunocompromised patients

- Burn Unit

- Cardiac Cath Lab

- Central Sterile Supply

- Intensive Care Units

- Negative pressure isolation rooms

- Oncology

- Operating rooms including C-section rooms

IIII

TYPE DTYPE CTYPE B

Class IVor control procedures are necessary.

CL

AS

S

IV

CL

AS

S

II

During Construction Project

CL

-I

CL

AS

S

III

1. Do not remove barriers from work area until completed project is inspected by the owner's Safety Department and Infection Prevention & Control Department and thoroughly cleaned by the owner's Environmental Services Department.

2. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.

3. Contain construction waste before transport in tightly covered containers.

4. Cover transport receptacles or carts. Tape covering unless solid lid.

5. Vacuum work area with HEPA filtered vacuums.

6. Wet mop area with cleaner/disinfectant.

7. Upon completion, restore HVAC system where work was performed.

1. Do not remove barriers from work area until completed project is inspected by the owner's Safety Department and Infection Prevention & Control Department and thoroughly cleaned by the owner's Environmental Services Department.

2. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.

3. Vacuum work area with HEPA filtered vacuums.

4. Wet mop area with cleaner/disinfectant.

5. Upon completion, restore HVAC system where work was performed.

1. Clean work area upon completion of task

Upon Completion of Project

1. Wipe work surfaces with disinfectant.

2. Contain construction waste before transport in tightly covered containers.

3. Wet mop and/or vacuum work area with HEPA filtered vacuum before leaving work areas.

4. Upon completion, restore HVAC system where work was performed.

1. Includes all activities required by Class II

2. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.

3. Complete all critical barriers i.e. sheetrock, plywood, plastic, to seal area from non work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.

4. Maintain negative air pressure within work site utilizing HEPA-equipped air filtration units.

5. Contain construction waste before transport in tightly covered containers.

6. Cover transport receptacles or carts. Tape covering unless solid lid.

1. Execute work by methods to minimize raising dust from construction operations.

2. Immediately replace a ceiling tile displaced for visual inspection.

1. Includes all activities required by Class I

2. Provide active means to prevent airborne dust from dispersing into atmosphere.

3. Water mist work surfaces to control dust while cutting.

4. Seal unused doors with duct tape.

5. Block off and seal air vents.

6. Place dust mat at entrance and exist of work area.

7. Remove or isolate HVAC system in area where work is being performed.

1. Includes all activities required by Class III

2. Isolate HVAC system in areas where work is being done to prevent contamination of duct system.

3. Complete all critical barriers i.e. sheetrock, plywood, plastic, to seal area from non work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.

4. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.

5. Seal holes, pipes, conduits, and punctures.

6. Construct anteroom and require all personnel to pass through this room so they can be vacuumed using a HEPA vacuum cleaner before leaving work site or they can wear cloth or paper coveralls that are removed each time they leave the work site.

7. All personnel entering work site are required to wear shoe covers. Shoe covers must be changed each time the worker exits the work area.

A-A-100

ELEVATOR

P3

43.1.1 CLASSIFICATION OF REHABILITATION WORK -

RENOVATION

43.4.2 CAPACITY OF MEANS OF EGRESS. THIS PROJECT

DOES NOT CHANGE OR ALTER EXISTING

OCCUPANT LOAD OR MEANS OF EGRESS. THE

EGRESS CAPACITY SHALL HAVE BEEN

PREVIOUSLY APPROVED AS BEING ADEQUATE.

NFPA 101 - CHAPTER 43

BUILDING REHABILITATION

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

1:

:5

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

A-G-001

MAPLE (BUILDING 3) ICRA FLOOR PLAN

1 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

Scale: 1/8" = 1'-0"

MAPLE (BUILDING 3) PARTIAL GROUND FLOOR PLAN

N O

R

TH0 4 8 16

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

REFERENCE CODES

AMERICAN WITH DISABILITIES ACT(ADA) STANDARDS, 2010

PG 18-13: VA BARRIER FREE DESIGN STANDARD, 2017

AMERICAN SOCIETY OF HEATING, REFRIGERATING AND

AIR -CONDITIONING ENGINEERS MANUAL(ASHRAE)

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES

AND STANDARDS

OSHA RULES AND REGULATIONS

2015 INTERNATIONAL BUILDING CODE

LIFE SAFETY CODE (NFPA 101) 2021

THE JOINT COMMISSION (TJC) ACCREDITATION MANUAL

(LATEST EDITION)

NATIONAL ELECTRICAL CODE (NEC) (NFPA 70) 2020

NATIONAL FIRE ALARM CODE (NFPA 72) 2022

2021 INTERNATIONAL FIRE CODE

ILLUMINATING ENGINEERING SOCIETY (IES) LIGHTING

HANDBOOK, 10TH EDITION

HEALTH CARE FACILITIES CODE (NFPA 99) 2021

VA ELECTRICAL DESIGN MANUAL, DEC. 2019

VA PHYSICAL SECURITY AND RESILIENCY DESIGN

MANUAL, APRIL 2021

VA DESIGN GUIDE: OFFICE OF INFORMATION AND

TECHNOLOGY, FEB. 2019

VA DESIGN GUIDE: INFRASTRUCTURE STANDARD FOR

TELECOMMUNICATIONS SPACES, JULY. 2021

ANSI/TIA/EIA 568-2020 COMMERCIAL BUILDING CABLING

STANDARDS

ANSI/TIA/EIA 569-C-2019 COMMERCIAL BUILDING

STANDARDS FOR TELECOMMUNICATIONS PATHWAYS AND

SPACES

ANSI/TIA-1179-2017 TELECOMMUNICATIONS SPACES FOR

HEALTHCARE FACILITIES

ASME A17.1/CSA B44-2019 ELEVATOR CODE

BICSI, TELECOMMUNICATIONS DISTRIBUTION METHODS

MANUAL, 14TH EDITION.

A. ALL MAJOR EQUIPMENT TRANSPORTED THROUGH

THE BUILDING TO BE VA APPROVED ROUTE AND

TIME. COORDINATE WITH VA COR GIVING 2 WEEKS

NOTICE MINIMUM.

B. WORK HOURS - 7:00 AM TO 6:00 PM.

C. COORDINATE WITH COR FOR PARKING

REQUIREMENTS.

D. PROVIDE STICKY MAT AT ALL CONSTRUCTION

ACCESS POINTS.

E. THE GC SHALL FILL OUT THE PROPER ISLM FORMS

WITH THE VA COR BEFORE ANY CONSTRUCTION

WORK COMMENCES.

F. GC TO PROVIDE A 1-HOUR CONSTRUCTION

BARRIER IF THE ELEVATOR DOOR WILL BE

REMOVED FOR REFURBISHMENT OR IF ELEVATOR

DOORS WILL BE REMOVED FOR REFURBISHMENT

OR REPLACEMENT WITHOUT REINSTALLATION ON

THE SAME DAY, LIMIT WORK TO ONE FLOOR AT A

TIME TO LIMIT THE POTENTIAL FOR SMOKE/HOT

GAS SPREAD BETWEEN FLOORS VIA THE

ELEVATOR SHAFT.

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

1:

:0

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

A-G-002

MAPLE (BUILDING 3) EXISTING PHOTOS

2 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

UP UP

NEW WALL

NEW DOOR

NEW WINDOW

NEW WORK LEGEND

ELEVATOR

EQUIP.

ROOM

4 5

9ELEVATOR

PIT

P3

CR

FD

STAIR

136A

ROOM

ROOM

ROOM

CORRIDOR

ROOM

11ELEVATOR

P3

ROOM

ROOM

CORRIDOR

ROOM

ROOM

11ELEVATOR

P3

ELEVATOR

EQUIP.

ROOM

ELEVATOR

PIT

P3

STAIR

136A

ROOM

ROOM

CORRIDORROOM

ROOM

ELEVATOR

P3

ROOM

ROOM

CORRIDOR

ROOM

ROOM

ELEVATOR

P3

EXISTING WALL TO REMAIN

EXISTING DOOR TO REMAIN

TEMPORARY DOOR

TEMPORARY WALL

DEMOLISH WALL

DEMOLISH DOOR

DEMOLISH WINDOW

EXISTING WINDOW TO REMAIN

DEMOLITION LEGEND

TEMPORARY WALL

TEMPORARY DOOR

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

1:

:5

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

A-A-100

MAPLE (BUILDING 3) ELEVATOR FLOOR

PLANS & DETAILS

3 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

1 PROVIDE NEW ELEVATOR CAB FINISHES.

2 PROVIDE NEW ELEVATOR PANEL/CONTROLS.

3 PROVIDE NEW ELEVATOR CAB DOOR.

4 PROVIDE NEW CODE COMPLIANT PIT LADDER. SEE

SHEET G-006 FOR PIT LADDER DETAILS

5 CARD READER WILL BE PLACED ON THE DOOR

FRAME.

6 NEW 90 MIN RATED DOOR AND FRAME, REFER TO

DOOR SCHEDULE FOR MORE INFORMATION.

7 PROVIDE WALL BRACKET AND SNOW HOOD COVER

FOR NEW MINI-SPLIT CONDENSING UNIT. SEE

MECH. DWGS FOR MORE INFORMATION.

8 OVERHEAD WALL MOUNTED MINI-SPLIT UNIT. DO

NOT PLACE DIRECTLY OVER ANY PROPOSED OR

EXIST. ELEVATOR EQUIPMENT THAT IS IN THE

ROOM

9 GC TO VERIFY IF EXISTING FIRE EXTINGUISHER IS

STILL CODE COMPLIANT. IF IT IS NOT CODE

COMPLIANT, THE GC WILL REPLACE THE EXISTING

FIRE EXTINGUISHER WITH A NEW CODE

COMPLIANT EXTINGUISHER AND BRACKET.

10 PROVIDE INTERIOR CONTROL PANEL.

11 PROVIDE NEW ELEVATOR HOISTWAY DOOR.

12 OIL INTERCEPTOR. SEE DETAIL 3/PF501 FOR MORE

INFORMATION.

13 ELEVATOR SUMP PUMP. SEE DETAIL 3/PF501 FOR

MORE INFORMATION.

N O

R

TH0 2 4 8

N O

R

TH0 2 4 8

N O

R

TH0 2 4 8

Scale: 1/4" = 1'-0"

ELEVATOR PIT & ELEV. EQUIP. ROOM NEW WORK FLOOR

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR NEW WORK PLAN

Scale: 1/4" = 1'-0"

SECOND FLOOR NEW WORK PLAN

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

N O

R

TH0 2 4 8

N O

R

TH0 2 4 8

N O

R

TH0 2 4 8

Scale: 1/4" = 1'-0"

ELEVATOR PIT & ELEV. EQUIP. ROOM DEMOLITION FLOOR

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR DEMOLITION FLOOR PLAN

Scale: 1/4" = 1'-0"

SECOND FLOOR DEMOLITION FLOOR PLAN

1 DEMOLISH EXISTING ELEVATOR CAB INTERIOR

FINISHES

2 DEMOLISH EXISTING ELEVATOR PANEL/CONTROLS

3 DEMOLISH EXISTING ELEVATOR CAB FRAME AND SS

DOORS. REAR DOOR TO BE INFILLED.

4 DEMOLISH EXISTING PIT LADDER

5 DEMOLISH EXISTING DOOR AND HM FRAME

6 REPAIR AND REPAINT EXISTING METAL CELLAR

DOORS

7 REMOVE LOUVER BLADES. PROVIDE NEW BLANK

OFF LOUVER PANEL IN LOUVER FRAME OPENING

8 REMOVE AND STORE EXISTING METAL FLOOD STOP

BRACING. REPLACE AFTER FLOOR REPAINTING.

9 DEMOLISH EXISTING ELEVATOR HOISTWAY DOOR

10 TRENCH OUT ELEVATOR PIT FOR NEW EQUIPMENT.

SEE PLUMBING DWGS FOR MORE INFORMATION.

A. SEE SHEET G-005 FOR GENERAL NOTES.

B. SEE SHEET A-A-400 FOR ELEVATOR P1 CAB

PLANS AND INTERIOR ELEVATIONS.

C. PATCH AND REPAIR ALL HOLES TO BE SEALED

WITH FIRESTOPPING.

D. PATCH, REPAIR, AND PAINT ALL GYPSUM BOARD

DAMAGED OR ALTERED DUE TO NEW ELEVATOR

WORK. INCLUDING BUT NOT LIMITED TO

REPLACING JAMB WORK AND CONTROL DEVICE

AND LANTERN CHANGE OUT WORK.

E. SEE SPECIFICATION SECTION 14 24 10 FOR

EQUIPMENT SCHEDULES AND ADDITIONAL

INFORMATION.

F. CEILING CONTRACTOR TO MEASURE EACH

CEILING AREA AND ESTABLISH A CEILING

LAYOUT TO BALANCE BORDER WIDTHS AT

OPPOSITE EDGES OF EACH ROOM. AVOID USE

OF LESS-THAN 6" TILES.

G. EXIST. METAL FLOOR FLOOD STOP BARS SHALL

BE REMOVED. THE EQUIP. RM. FLOOR SHALL BE

PAINTED. THE FLOOR FLOOD STOP BARS SHALL

BE REINSTALLED.

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

-0

PROVIDE NEW MAIN

CAR OPERATING

PANEL IN THE CAR

ENCLOSURE ON THE

FRONT RETURN

PANEL. CONTRACTOR

TO VERIFY LOCATION

PER CAB INTERIOR.

SEE ELEVATOR

SPECIFICATIONS

PROVIDE CAB WITH NEW

TWO-SPEED SIDE

HORIZONTAL SLIDING

HOISTWAY DOORS .

PROVIDE CAR ENCLOSURE

WITH NEW S.S. PANELS

ABOVE ELEVATOR DOOR.

COORDINATE

EMERGENCY EXIT

HATCH WITH CAB

CEILING

PROVIDE CCTV

CAMERA INSIDE OF

THE CAR. SEE

ELECTRICAL SHEETS.

PROVIDE (6) LED

ILLUMINATED CAR

LIGHT FIXTURES

ABOVE THE CEILING.

MAINTAIN A MINIMUM

LIGHT LEVEL OF 50-

FOOT CANDLES AT

(36") ABOVE THE

FINISHED FLOOR.

PROVIDE S.S.

HANGING CEILING

FRAME. CONSTRUCT

FRAME OF .125" X

1.50" X 1.50" "T" AND

"L" SECTIONS.

SEE SCHEDULE

1" EQ EQ 1"

1"

EQ

1/ 2"

EQ

1/

2"

EQ

1"

SE

E

SC

H

ED

U

LE

1/2"

8' -0

PROVIDE CAR

ENCLOSURE WITH

NEW S.S. CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH NEW

HANDRAIL @ CENTERLINE OF 30" AND

42" ABOVE THE CAR FLOOR. MATCH

EXIST. SPACING OF HANDRAIL FROM

CAB WALL. CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL BE

REMOVABLE FROM THE INSIDE OF THE

CAR ENCLOSURE. LOCATE HANDRAILS

1-1/2" FROM CAB WALL. PROVIDE 1-1/2"

S.S. ROUND HANDRAILS WITH THE ENDS

AT THE ENTRANCE TURNED BACK TO

THE WALL.

PROVIDE NEW CAR

ENCLOSURE. FINAL PANEL

DESIGN TO BE APPROVED BY

VA INTERIOR DESIGNER

1' -0

2'

-6

4"

1" EQ 1/2" EQ 1/2" EQ

8"

PROVIDE NEW 8" TALL CRASH RAIL

@12" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

SEE SCHEDULE

7' -0

3' -6

CALL BUTTON.

HOISTWAY DOORS

TO BE REPLACED -

SEE ELEVATOR

SPECIFICATIONS.

NEW

COMBINATION

HALL LANTERNS

AND PLATES TO

BE INSTALLED.

RECLAD EXISTING

STAINLESS STEEL

ENTRANCE FRAME,

AND TOP HEADER.EMERGENCY

ACCESS

KEYWAY PLATES

TO BE

REPLACED.

SIGNAGE TO BE

REPLACED. SEE

INTERIORS. SIGNAGE TO BE

REPLACED. SEE

INTERIORS.

8' -0

TOP OF CAB

1' -0

2'

-6

4"

1" EQ 1/2" EQ 1"

8"

PROVIDE CAR

ENCLOSURE WITH

NEW S.S. CEILING

PROVIDE CAR ENCLOSURE WITH

NEW HANDRAIL @ CENTERLINE OF

30" AND 42" ABOVE THE CAR

FLOOR. MATCH EXIST. SPACING OF

HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL BE

REMOVABLE FROM THE INSIDE OF

THE CAR ENCLOSURE. LOCATE

HANDRAILS 1-1/2" FROM CAB WALL.

PROVIDE 1-1/2" S.S. ROUND

HANDRAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

PROVIDE NEW CAR

ENCLOSURE. FINAL

PANEL DESIGN TO BE

APPROVED BY VA

INTERIOR DESIGNER

PROVIDE NEW 8" TALL CRASH RAIL

@12" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

SEE SCHEDULE

PASSENGER ELEVATOR CAB SIZE SCHEDULE

ELEVATOR WIDTH DEPTH

P3 62" 92"

RATED LOAD

4,000 (lbs)

A-A-400 26

PROVIDE NEW CAR ENCLOSURE

WITH NEW FLOORING.

5' -2

7'-8"

NEW SECURITY

CAMERA

ELEVATOR

P3

ENTRANCE FRAME TYPE:

1. SWEEP JAMB AT EACH LEVEL OF THE

ELEVATOR ENTRANCE.

2. REFER TO SHEET G-006 FOR JAMB AND HEAD

DETAIL

DOOR HARDWARE NOTES:

1. PROVIDE 90 MIN RATED H.M. FRAME IN EXISTING OPENING. PROVIDE RATING LABEL FOR DOOR AND FRAME.

2. PROVIDE CARD READER/PACS DEVICE AT NEW DOOR OPENING.

3. FBC APPROVED HARDWARE TO BE USED ON NEW DOOR IN THIS OPENING.

4. COORDINATE HARDWARE REQUIREMENTS WITH NEW FRAME. VERIFY LOCK FUNCTIONS AND HARDWARE COMPATIBILITY PRIOR TO ORDERING ANY HARDWARE

5. PROVIDE NEW SECURITY CAMERA AT CORRIDOR SIDE OF DOOR OPENING.

6. SEE HARDWARE SETS IN SPECIFICATION 08 71 00 FOR DOOR COMPONENTS.

7. PROVIDE WELDED FRAMES PER VA REQUIREMENTS, SEE SPECIFICATIONS FOR MORE INFORMATION.

DOOR REMARKS:

1. PROVIDE ELECTRIC WIRING TO CARD READER AND ELECTRIC STRIKE. SEE ELECTRICAL DWGS. FOR MORE INFORMATION.

F

SE

E

SC

H

ED

U

LE

SCHEDULE

SEE

F-1

2" 2"

SCHEDULE

SEE

SE

E

SC

H

ED

U

LE

2"

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

1:

:5

PM

C :\U se rs

\b ne ed ha m \D oc um en ts

\A _2

1-

9_ Le ed s-

In st al l E le v_ bn ee dh am

8H

L.

rv t

A-A-400

MAPLE (BUILDING 3) ELEVATOR

BUILDING SECTION & INTERIOR CAB

ELEVATIONS

4 4OKM

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

JAB

Scale: 3/4" = 1'-0"

CAB INTERIOR - FRONT ELEVATION - MAPLE

Scale: No Scale

ELEVATOR CAB - CEILING PLAN - MAPLE

Scale: No Scale

CAB INTERIOR - SIDE ELEVATION - MAPLE

Scale: 3/4" = 1'-0"

TYPICAL PASSENGER CAB - EXTERIOR ELEVATION - MAPLE

Scale: No Scale

CAB INTERIOR - REAR ELEVATION - MAPLE

Scale: 3/4" = 1'-0"

ELEVATOR CAB FLOOR PLAN - MAPLE

HUNTLEY

HUNTLEY ASSOCIATES, P.C.

SURVEYORS ● CIVIL/SITE/STRUCTURAL/BUILDING ENGINEERS

30 INDUSTRIAL DRIVE EAST

NORTHAMPTON, MASSACHUSETTS 10160

DOOR SCHEDULE

ROOM NAME

DOOR DOOR FRAME

LBL

HDWR

SET REMARKSNO. WIDTH HEIGHT THICK MAT'L FINISH ELEV MAT'L FINISH ELEV

ELEVATOR

EQUIP. ROOM

002 3' - 0" 7' - 0" 1 3/4" MTL PNT F HM PNT F-1 90 MIN. 1.0 1

ROOM FINISH SCHEDULE

ROOM NO. NAME FLOOR BASE

WALLS

REMARKSEAST NORTH SOUTH WEST

002 ELEVATOR EQUIP. ROOM EPF-1 RB-1 P-4 P-4 P-4 P-4 FLOOD STOPS TO BE REMOVED, FLOOR TO RECIEVE

EPOXY PAINT, FLOOD STOP TO BE RE-INSTALLED

Scale: 1/2" = 1'-0"

MAPLE EQUIPMENT ROOM DOOR TYPE

Scale: 1/2" = 1'-0"

MAPLE EQUIPMENT ROOM FRAME TYPE

POSITION INDICATORS IN HALLWAY/LOBBY SHOULD

DISPLAY "OUT OF SERVICE", FOR FIRE SERVICE,

INDEPENDENT SERVICE, ELEVATOR INSPECTION, ETC.

CRAWL SPACE - NO ACCESS

ELEVATOR EQUIP. ROOM

ELEVATOR PIT

P3

1 1/2" PD

CRAWL SPACE - NO ACCESS

ELEVATOR EQUIP. ROOM

ELEVATOR PIT

P3

1 3-SP-1

1 1/2" PD

3-SP-2

3" PD

CO

4" SAN

3" PD

FD-B

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

5:

:1

PM

C :\U se rs

\s ge or ge

\D oc um en ts \R ev it

Fi le s\ R ev it

\M _2

1-

9_ Le ed s-

In st al l E le v_ sp ge or ge

.rv t

A-PF101

MAPLE (BUILDING 3) PLUMBING AND

FIRE SUPPRESSION PLAN

1 1AV

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

SPG

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1 PROVIDE NEW SUMP PUMP IN ELEVATOR

MACHINE ROOM. CONNECT TO EXISTING DRAIN

PIPING.

2 TRENCH OUT ELEVATOR PIT FOR NEW SUMP

PUMP, OIL INTERCEPTOR, AND FLOOR DRAIN IN

ELEVATOR PIT. COORDINATE EXACT

LOCATIONS WITH ELEVATOR STRUCTURAL

SUPPORTS.

3 ROUTE PUMP DISCHARGE TO CRAWL SPACE,

DISCHARGE TO TOP OF EXISTING 4" SANITARY

PIPE.

4 PROVIDE QUICK RESPONSE SPRINKLER HEADS

IN ELEVATOR PIT. EXTEND SPRINKLER PIPE

FROM MACHINE ROOM.

5 SLEEVE AND FIRE SEAL PIPE PENETRATION

THROUGH ELEVATOR SHAFT WALL.

6 ROUTE SEPARATE 2" VENTS FROM OIL

INTERCEPTOR AND SUMP PUMP UP TO 18'

ABOVE PIT FLOOR.

Scale: 1/4" = 1'-0"

BASEMENT FLOOR PLUMBING AND FIRE SUPPRESSION

DEMOLITION PLAN

Scale: 1/4" = 1'-0"

BASEMENT FLOOR PLUMBING AND SUPPRESSION NEW

WORK PLAN

1 DEMOLISH EXISTING SUMP PUMP IN ELEVATOR

MACHINE ROOM. EXISTING PUMP DISCHARGE

PIPING TO REMAIN.

N O

R

TH0 2 4 8

N O

R

TH0 2 4 8

A. SLEEVE ALL PENETRATIONS. FIRESTOP AND

SEAL WATER TIGHT.

B. REUSE EXISTING FIRE SUPPRESSION MAINS

WHERE POSSIBLE. PROVIDE NEW BRANCH

PIPNG AS REQUIRED.

C. EXISTING FIRE AND SMOKE ZONES SHALL BE

MAINTAINED.

Scale: 12" = 1'-0"

CRAWLSPACE PLUMBING PLAN 3

N O

R

TH0 4 8 16

CRAWL SPACE - NO ACCESS

ELEVATOR EQUIP. ROOM

ELEVATOR PIT

P3

3-SS-1

3-CU-1

2 3

T S3/4" D

RS RL

CRAWL SPACE - NO ACCESS

ELEVATOR EQUIP. ROOM

ELEVATOR PIT

P3

EXISTING UNIT HEATER TO REMAIN

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Numbers

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

1, 2, 3, 5, 8, 11, 12 & 25

6/

/2

5:

:2

PM

C :\U se rs

\s ge or ge

\D oc um en ts \R ev it

Fi le s\ R ev it

\M _2

1-

9_ Le ed s-

In st al l E le v_ sp ge or ge

.rv t

A-M-101

MAPLE (BUILDING 3) MECHANICAL

PLAN

1 1AV

MODERNIZE, REPLACE OR

INSTALL ELEVATORS IN 8

BUILDINGS

VA CENTRAL WESTERN MA

HEALTHCARE SYSTEM - LEEDS

421 NORTH MAIN STREET

LEEDS, MA 01053 JUNE 27, 2023

BID DOCUMENTS

631-21-01121-169

SPG

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/4" = 1'-0"

BASEMENT FLOOR MECHANICAL NEW WORK PLAN

A. COORDINATE ALL DEMOLITION WORK WITH THE

GENERAL CONTRACTOR, OTHER TRADES AND

THE COR TO MINIMIZE DISRUPTION OF AREAS

OUTSIDE OF THE PROJECT LIMITS OF WORK.

B. ALL DEMOLISHED EQUIPMENT…

This is the start of the file's text. The full file is on GovTribe.