6-Exhibit A - Approved Variance.pdf
PDF 8 MB Posted
- Attached to
- 3Kings Golf Netting
- Solicitation number
- PCMC27002 - WAT (revised)
- Issued by
- Summit County, Utah
About this file
Summary: Exhibit A - Approved Variance
This is a conceptual design exhibit supporting a contract opportunity issued by Park City Municipal Corporation (PCMC) in Utah for the design and installation of protective golf netting at the 3Kings Water Treatment Plant. The project aims to mitigate errant golf balls from the Park City Municipal Golf Course that are impacting the water treatment facility. The approved variance document includes a conceptual design map showing the proposed netting alignment, which features three steel poles positioned to intercept estimated golf ball trajectories from the 12th hole tee box. The design incorporates approximately 40-50 foot tall existing pine trees as natural barriers and includes new trees to be installed in front of the netting structure to enhance both protection and aesthetics. The document references supporting exhibits including a conceptual design image and example photos provided by the consultant demonstrating comparable netting installations.
The variance approval represents authorization for the proposed project scope and design approach, establishing the baseline specifications for qualified respondents to develop detailed design and installation proposals. The document confirms site conditions including the presence of existing vegetation and the specific geometry of the golf ball trajectory threat, providing critical information for bidders to prepare accurate cost estimates and installation methodologies.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Line
Image
Harrison.Holley Image
Harrison.Holley Rectangle
Harrison.Holley Line
Harrison.Holley Line
Harrison.Holley Dimension 100'
Harrison.Holley Text Box Exhibit A
GOLF BALL NETTING CONCEPTUAL DESIGN
3KINGS WATER TREATMENT PLANT
Harrison.Holley PolyLine
Harrison.Holley Callout
APPROX. 40'-50' TALL PINE TREE
Harrison.Holley Callout
APPROX. 40'-50' TALL PINE TREE
Harrison.Holley Text Box
THREE KINGS DRIVE
Harrison.Holley Text Box
3KINGS KINGS WATER TREATMENT PLANT
Harrison.Holley Arc
Harrison.Holley Callout
ESTIMATED GOLF BALL TRAJECTORY FROM 12TH HOLE TEE BOX
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Callout PRELIMINARY GOLF BALL NETTING ALIGNMENT WITH 3x STEEL POLES
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Ellipse
Harrison.Holley Callout
NEW TREES INSTALLED IN FRONT OF NETTING
Harrison.Holley Callout
NEW TREE INSTALLED IN FRONT OF NETTING
Harrison.Holley Polygon
Harrison.Holley Polygon
Harrison.Holley Rectangle
Harrison.Holley Rectangle
Harrison.Holley Text Box
EXHIBIT B
GOLF BALL NETTING CONCEPTUAL DESIGN IMAGE
Text Box Exhibit C
Example Photos from Consultant
Harrison.Holley Image
Harrison.Holley Image
| 1884 Three Kings Drive Signed Variance Final Action Letter |
| Attachment 1 Proposed Plans |
| Exhibit B Thaynes proposed plans |
| Three Kings Proposed Plans |
| Exhibit A - Conceptual Design Map |
| Exhibit B - Conceptual Design Image |
| Exhibit C - Example Photos |
File details come from the government source that posted it. Updated .