This is a Product Specifications document (Attachment C) for Broward County's Interior Signage project for the Public Safety Building located at 2601 W Broward Boulevard, Fort Lauderdale, Florida. The project requires the manufacture, packaging, and delivery of interior room identification signage, including permanent room numbers and updateable room functions that comply with the Florida Building Code, 2010 ADA Standards for Accessible Design, and all relevant accessibility requirements. Signs are available in six types with specified dimensions ranging from 8.5" by 5.75" to 8.5" by 9", though custom sizes may be approved by the Facility Management Project Manager when required by room name length or architectural constraints. The successful bidder is responsible for manufacturing complete, labeled, and ready-to-install signage with all components properly assembled; installation will be performed by Broward County. The vendor must coordinate delivery dates with the Broward County Project Manager and ensure all signage is packaged to prevent damage during transportation and storage. Any damaged or defective signage must be replaced by the manufacturer at no additional cost to Broward County, with deliveries required during normal business hours Monday through Friday unless otherwise approved.
All signage must meet specific construction and design requirements, including uniform 8-inch width for standard paper inserts, non-glare acrylic windows, Grade II Braille specifications with hemispherical dots protruding a minimum 0.025 inches, and ADA-compliant typography using Futura font with tactile room numbers between 5/8-inch and 3/4-inch high. Signs must provide a minimum 70 percent light reflectance value contrast between characters and background with a matte or low-glare finish, utilizing specified finishes of Space Hatch base, Satin Silver trim, and White text. The vendor must submit shop drawings, finish and color samples, and full-size mock-ups for each sign type for County review and approval prior to fabrication. Mounting specifications require placement adjacent to the latch side of doors with tactile text positioned between 48 and 60 inches above finished floor, using high-strength VHB tape or concealed mechanical fasteners depending on wall substrate.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTTACHMENT C
Project: Public Safety Building 2nd Floor Interior Signage
Project Location:
2601 W Broward Blvd.
Fort Lauderdale, FL 33312
1. General Scope
This section defines the requirements for the fabrication and delivery of interior room identification signage, including permanent room numbers and updateable room functions. Signage shall comply with applicable federal, state, and local codes, including the Florida Building Code, the 2010 ADA Standards for Accessible
Design, and all relevant accessibility requirements.
2. Sign Requirements
2.1 Dimensions
• Chart with size per type:
Sign type Sign Size
A 8.5”L x 5.75”H
C 8.5”L x 5.75”H
D 8.5”L x 9”H
E 8.5”L x 9”H
H 8.5”L x 9”H
I 8.5”L x 9”H
• Custom sizes may be used only where required by room name length or architectural constraints. Any deviation from sign specifications must be approved by the Facility Management Project Manager in advance of fabrication.
2.2 Construction
• Signage shall, with the exception of directories and directionals, be a uniform 8 ½” width to facilitate inserts printed on standard width paper.
• Insert components shall have a .080 thick non-glare acrylic window and shall be inlaid flush to sign face for a smooth, seamless appearance.
• Signage shall include opening allowing for inserts, notice holders, occupancy sliders, markers, magnetic, and cork boards. All openings shall be flush to sign face for a smooth, seamless appearance.
• The sign finish (front and back) shall be pressure laminated and precision machined together to a 90-degree angle. Edges shall be smooth, void of chips, burrs, sharp edges and marks.
• Signage shall utilize acrylic sphere for Grade II Braille inserted directly into a scratch resistant, high pressure laminate sign face. Braille dots are to be pressure fit in high tolerance drilled holes.
• Braille dots shall be half hemispherical domed and protruding a minimum
0.025”.
• Signage shall utilize a pressure activated adhesive. The adhesive shall be nonhazardous and allow for flexing and deflection of the adhered components due to changes in temperature and moisture without bond failure.
• All signs shall be provided with appropriate mounting hardware. Hardware is to be finished and smooth in appearance and suitable for the mounting surface.
• Signs will not be installed on glass surfaces, Installer shall find an appropriate adjacent area to install room signs.
2.3 Sign Paper Insert
For sign type A:
• The signage shall accommodate polycarbonate inserts (for clear), or printed paper inserts by Owner to allow updating as required.
• Manufacturer shall provide a template containing layout, font, color, artwork and trim lines to allow Owner to produce inserts on laser or ink jet printer.
Template shall be in an Acrobat or Word format (.pdf).
• Insert area measures 4 inches wide x 1.25 inches high.
• Insert area must be protected from dust, moisture, and tampering.
• Vendor to provide digital file template in Word format for paper insert.
3. Typography and Tactile Lettering
• Signs and their installation shall comply with the applicable provisions of the latest edition of the following standards and with requirements of authorities having jurisdiction:
• ADAAG – Americans with Disabilities Act Accessibility Guidelines; US
Architectural and Transportation Barriers Compliance Board.
• International Code Council/American National Standards Institute A117.1-
Standard on Accessible and Usable Buildings Facilities.
• National Fire Protection Association 101 Life Safety Code.
• Tactile Room Numbers: Minimum 5/8-inch high, Maximum 3/4-inch high, raised
• Sign font shall be ADA Futura.
4. Color and Contrast
• All signs must provide a minimum 70% light reflectance value (LRV) contrast between characters and background.
• All components (including inserts) shall maintain compliance with ADA visibility requirements under standard courthouse lighting.
• Surface finish shall be matte or low-glare to minimize reflections.
• Finishes:
o Base: Space Hatch, 500-00023 o TRIM: Satin Silver o TEXT: White
5. Mounting and Installation
• All signage is to be installed by our contractor.
5.1 Placement
• Signs must be mounted adjacent to the latch side of the door, with tactile text located:
o 48 inches minimum above the finished floor to the baseline of the lowest tactile line o 60 inches maximum to the highest tactile line
5.2 Mounting Method
• Use high-strength VHB tape or concealed mechanical fasteners depending on wall substrate.
• All signs must be level, plumb, and installed flush to wall surfaces.
6. Submittals and Approvals
The vendor is to provide the following for review and approval by the County prior to fabrication.
o Shop drawings o Finish and color samples o Full-size sign mock-up for each sign type
File details come from the government source that posted it. Updated .