6-08. Project Plans (6 Sheets).pdf
PDF 12 MB Posted
- Solicitation number
- Not on record
- Issued by
- Bucks County, Pennsylvania
About this file
Summary of Project Plans for N. Main Street & University Drive Stormwater Improvements - Phase 1
This document is a set of project plans prepared by Remington & Vernick Engineers for Yardley Borough Sewer Authority in Bucks County, Pennsylvania, detailing stormwater infrastructure improvements funded through a PA Small Water & Sewer Grant. The project scope encompasses the replacement of deteriorated storm sewer infrastructure within a Borough-owned easement located at the intersection of N. Main Street and University Drive on a property owned by Grist Mill Properties (Tax Map Parcel No. PID 54-003-147, approximately 1.606 acres zoned C-1 Pedestrian-Oriented Commercial District). The work includes replacement of existing storm pipe with 36-inch Reinforced Concrete Pipe (RCP) for a length of 181 linear feet, one connection to existing structures, installation of a cast-in-place Type D concrete endwall, clearing of the existing outfall area (60 square yards), removal of one 15-inch diameter tree, permanent pavement restoration (151 square yards), concrete sidewalk restoration (5 square yards), televising and cleaning of the existing storm sewer system, and installation of a DCED project sign. The six-sheet plan set includes a title sheet, general notes and distribution of quantities, legend, site and utility plan, and two construction details sheets, with construction specifications aligned with PennDOT Publication standards and requirements under Pennsylvania Act 287 of 1974.
The plans establish comprehensive construction requirements including erosion and sediment control measures, demolition protocols, utility coordination procedures, concrete and pavement construction standards, and site safety and restoration obligations. All contractors and subcontractors must submit construction notifications through the PA One Call System (Serial Number 202661591190) no less than three and no more than ten business days prior to excavation or demolition work. The contractor is responsible for all costs associated with dewatering, temporary bypass pumping, traffic maintenance and protection, pre-construction videography, and restoration of disturbed features including mailboxes, irrigation systems, and landscaping. Key specifications include eight-inch compacted fill layers, adjustment of existing manholes and utility covers to five-eighths inch below proposed pavement surfaces, use of PennDOT No. 2A coarse aggregate for backfill beneath structures and pavement areas, and permanent stabilization of all disturbed areas with minimum 70 percent perennial vegetative cover or equivalent non-vegetative permanent cover. The project design was completed on June 18, 2026, with the survey work completed on May 26, 2026, under the supervision of PA Professional Land Surveyor Brian T. Yorkiewicz (License No. SU-075193).
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION MAP
N. MAIN STREET & UNIVERSITY DRIVE
STORMWATER IMPROVEMENTS - PHASE 1
YARDLEY BOROUGH
BUCKS COUNTY, PENNSYLVANIA
PHASE 2
(BY OTHERS)
PA SMALL WATER & SEWER GRANT
YARDLEY BOROUGH
FUNDING SOURCE:
JUNE 2026
N
PA ONE - CALL SYSTEM
R
1-800-242-1776
P E
S
L
N
AC L
YLS N
P
N
OT
V A
EB FO
AI O
UYE O
C LA L
D
STE
S
IG
Y
M I
CN
SERIAL # 202661591190
E
TI
TL
E
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_B uc ks \0
3_ Ya rd le y\ T\
T0
_2
6_ N or th
M ai n St
U ni ve rs ity
D r D ra in ag e
R ep la ce m en t\0 2_
D es ig n_ th ru
_C on tra ct s\
_C
AD
D \0
2_ M un i\D
W G
\P A0
3T
4- K.
dw g
/1
8/
1:
:3
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
PROFESSIONAL ENGINEER LIC. NO. PE-0055338-E
CHRISTOPHER J. FAZIO
DATE:
WEB ADDRESS : RVE.COM
(267) 394-4500
LOWER MAKEFIELD CORPORATE
YARDLEY, PA 19067
REMINGTON
& VERNICK
ENGINEERS
1010 STONY HILL ROAD, SUITE 175
CENTER NORTH CAMPUS
· Excellence Innovation Service·
JMB MEW CJF
of 5-26-2026
PA091593T004
AS NOTED
YA
R
D
LE
Y
BO
R O
U G
H
YA
R
D
LE
Y
BO
R O
U G
H
BU
C
KS
C O
U N
TY
PE
N N
SY
LV
AN
IA
N . M
AI
N
S
TR
EE
T
U
N
IV
ER
SI
TY
D
R
IV
E
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
PH
AS
E
YARDLEY BOROUGH SEWER AUTHORITY
56 SOUTH MAIN STREET
YARDLEY, PA 19067
215-493-2045
LIST OF UTILITIES AND
EMERGENCY CONTACT INFORMATION
PUBLIC
WORKS:
WATER:
SEWER:
FIRE
DEPARTMENT:
POLICE
DEPARTMENT:
ELECTRIC:
CABLE:
GAS:
TELEPHONE:
PENNSYLVANIA AMERICA WATER COMPANY
1145 EDGEWOOD RD
YARDLEY, PA 19067
215-493-3346
YARDLEY BOROUGH PUBLIC WORKS
56 SOUTH MAIN STREET
YARDLEY, PA 19067
215-493-6832
YARDLEY-MAKEFIELD FIRE COMPANY STATION 0
105 S. MAIN STREET
YARDLEY, PA 19067
215-493-4211
YARDLEY BOROUGH POLICE DEPARTMENT
56 SOUTH MAIN STREET
YARDLEY, PA 19067
215-493-2782
PECO ENERGY COMPANY
2301 MARKET STREET
PHILADELPHIA, PA 19103
1-800-494-4000
COMCAST CABLE SERVICES
ONE COMCAST CENTER 1701 JFK BOULEVARD
PHILADELPHIA, PA 19103
215-943-5272
PECO ENERGY COMPANY
2301 MARKET STREET
PHILADELPHIA, PA 19103
1-800-494-4000
COMCAST CABLE SERVICES
ONE COMCAST CENTER 1701 JFK BOULEVARD
PHILADELPHIA, PA 19103
215-943-5272
PHASE 1 - SITE
SHEET INDEX
SHEET # DESCRIPTION
1 TITLE
2 GENERAL NOTES & DISTRIBUTION OF QUANTITIES
3 LEGEND
4 SITE & UTILITY PLAN
5 CONSTRUCTION DETAILS - 1
6 CONSTRUCTION DETAILS - 2
06/18/2026
G
EN
ER
AL
N O
TE
S
D
IS
TR
IB
U
TI
O
N O
F Q
U
AN
TI
TI
ES
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_B uc ks \0
3_ Ya rd le y\ T\
T0
_2
6_ N or th
M ai n St
U ni ve rs ity
D r D ra in ag e
R ep la ce m en t\0 2_
D es ig n_ th ru
_C on tra ct s\
_C
AD
D \0
2_ M un i\D
W G
\P A0
3T
4-
ED
Q .d w g
/1
8/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
PROFESSIONAL ENGINEER LIC. NO. PE-0055338-E
CHRISTOPHER J. FAZIO
DATE:
WEB ADDRESS : RVE.COM
(267) 394-4500
LOWER MAKEFIELD CORPORATE
YARDLEY, PA 19067
REMINGTON
& VERNICK
ENGINEERS
1010 STONY HILL ROAD, SUITE 175
CENTER NORTH CAMPUS
· Excellence Innovation Service·
JMB MEW CJF
of 5-26-2026
PA091593T004
AS NOTED
YA
R
D
LE
Y
BO
R O
U G
H
YA
R
D
LE
Y
BO
R O
U G
H
BU
C
KS
C O
U N
TY
PE
N N
SY
LV
AN
IA
N . M
AI
N
S
TR
EE
T
U
N
IV
ER
SI
TY
D
R
IV
E
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
PH
AS
E
PROJECT INFORMATION
1. TAX MAP PARCEL NO(S): PID 54-003-147
2. OVERALL TRACT AREA: +/- 1.606 AC
3. PROPERTY OWNER(S): N/F GRIST MILL PROPERTIES
4. ZONING: C-1 PEDESTRIAN-ORIENTED COMMERCIAL DISTRICT
5. THE PURPOSE OF THIS PROJECT IS TO DEPICT THE REPLACEMENT OF STORM SEWER INFRASTRUCTURE WITHIN A BOROUGH-OWNED
EASEMENT ON THE SUBJECT PROPERTY.
EXISTING CONDITIONS & SURVEY NOTES
1. THE HORIZONTAL DATUM IS BASED ON THE PENNSYLVANIA STATE PLAN COORDINATE SYSTEM SOUTH ZONE (NAD-1983 / 2011 ADJ.) AND
THE VERTICAL DATUM IS BASED ON NAVD-1988 / 2018 GEOID (ADD 1.00 FEET TO THESE ELEVATIONS TO CONVERT TO NGVD-1929
DATUM).
2. EXISTING TOPOGRAPHIC CONDITIONS WERE SURVEYED BY REMINGTON & VERNICK ENGINEERS UNDER THE SUPERVISION OF BRIAN T.
YORKIEWICZ, PA. P.L.S. NO. SU-075193. THE SURVEY WORK WAS COMPLETED ON MAY 26, 2026.
3. PROPERTY AND RIGHT-OF-WAY LINES SHOWN ON THESE PLANS ARE BASED ON FIELD EVIDENCE FOUND AND MAPS AND DEEDS OF RECORDS AS WELL AS CURRENT ASSESSMENT RECORDS & TAX MAPS OF THE BOROUGH OF YARDLEY, BUCKS COUNTY, PENNSYLVANIA. ADJOINING PROPERTY AND RIGHT-OF-WAY LINE ARE SHOWN FOR GRAPHICAL INFORMATION ONLY AND HAVE NOT
BEEN FIELD VERIFIED.
4. THIS PLAN HAS BEEN BASED UPON THE FOLLOWING REFERENCE MATERIAL(S):
a. FILED MAP - LOT LINE CHANGE / MINOR SUBDIVISION PLAN PREPARED FOR GRIST MILL PROPERTIES AND REVI & JENNIFER RAJA, SITUATE IN YARDLEY BOROUGH, BUCKS COUNTY, PENNSYLVANIA, PREPARED BY PICKERING CORTS & SUMMERSON, INC., CONSULTING ENGINEERS AND LAND SURVEYORS., DATED JANUARY 26, 2015, AND LAST REVISED AUGUST 5, 2016, FILED IN BUCKS
COUNTY AS INSTRUMENT NUMBER 2016071973.
5. A FINAL DESIGN REQUEST FOR UNDERGROUND UTILITY OR STRUCTURE INFORMATION HAS BEEN SUBMITTED THROUGH THE PA ONE CALL SYSTEM FOR THIS PROJECT. THE FINAL DESIGN REQUEST SERIAL NUMBER FOR THIS PROJECT IS 202661591190.
6. THIS PLAN AND SURVEY DOES NOT CERTIFY THE LOCATION, BOTH HORIZONTAL AND VERTICAL, OF ANY UNDERGROUND UTILITY OR
STRUCTURE THAT WAS NOT EXPOSED FOR DIRECT MEASUREMENT.
7. THIS SURVEY AND PLAN WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT. PROPERTY IS SUBJECT TO SUCH STATE OF FACT THAT AN ACCURATE TITLE REPORT MY REVEAL INCLUDING ANY EASEMENTS, RESTRICTIONS AND ENCUMBRANCES.
8. BEARINGS SHOWN ON THIS PLAN HAVE BEEN ROTATED TO THE PENNSYLVANIA STATE PLANE COORDINATE SYSTEM AND MAY NOT
MATCH ANY PREVIOUSLY RECORDED DEEDS OR PLANS.
9. OFFSET DIMENSIONS SHOWN HEREON ARE NOT TO BE USED FOR ESTABLISHING PROPERTY LINES, SETBACK LINES, FOR CONSTRUCTION OF ANY TYPE OR ANY OTHER PURPOSES OTHER THAN THE INTENDED USE OF THIS SURVEY.
10. ACCORDING TO FEMA FLOOD INSURANCE RATE MAP (FIRM) PANEL NO. 42017C0452J, EFFECTIVE 3/16/2015, THE PROJECT AREA IS NOT
LOCATED WITHIN A SPECIAL FLOOD HAZARD AREA (SFHA).
11. ACCORDING TO THE NATIONAL WETLANDS INVENTORY MAINTAINED BY THE U.S. FISH AND WILDLIFE SERVICE THE PROJECT ARE DOES
NOT CONTAIN WETLAND AREAS.
12. BASELINES HAVE BEEN PROVIDED ON THE PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE THE BASELINE AS
SHOWN ON THE PLANS.
13. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD.
ANY ERRORS OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY.
EROSION & SEDIMENT CONTROL (E&S) NOTES
1. THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL TEMPORARY E&S BEST MANAGEMENT PRACTICES (BMPS) DURING THE
CONSTRUCTION. TEMPORARY E&S BMPS SHALL INCLUDE ANY DEPICTED ON THE PLANS AND THE FOLLOWING:
a. STORM INLET PROTECTION. INLET FILTER BAGS SHALL BE INSTALLED IN EACH EXISTING AND PROPOSED STORM INLET RECEIVING
RUNOFF FROM THE PROJECT AREA.
b. SEDIMENT BARRIERS. COMPOST FILTER SOCK, SILT FENCE OR OTHER SUITABLE BARRIERS SHALL BE INSTALLED ON LEVEL GRADE
DOWNSTREAM FROM DISTURBED AREAS AND STOCKPILES.
c. CONCRETE WASHOUT. FOR ANY PROJECT WHERE CONCRETE WILL BE POURED ON SITE, A SUITABLE WASHOUT FACILITY MUST BE
PROVIDED.
d. PUMPED WATER FILTER BAG. A PUMPED WATER FILTER BAG SHALL BE USED TO FILTER WATER PUMPED FROM EXCAVATED AREAS
(DEWATERING), SEDIMENT STORAGE AREAS OF SEDIMENT BASINS AND SEDIMENT TRAPS.
2. E&S BMPS SHALL BE INSPECTED AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL
MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMPS OR MODIFICATIONS OF THOSE
INSTALLED WILL BE REQUIRED.
3. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY E&S BMPS. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST
ACCELERATED EROSION.
DEMOLITION NOTES
1. BEFORE BEGINNING ANY DEMOLITION WORK, THE CONTRACTOR SHALL INSTALL E&S BMPS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, TRANSPORTATION, AND PROPER DISPOSAL OF ALL DEMOLISHED
MATERIALS. DEMOLISHED MATERIALS MUST BE MOVED OFFSITE TO AN APPROVED FACILITY.
3. THE CONTRACTOR SHALL PERFORM DEMOLITION WORK AS NECESSARY TO FACILITATE THE PROPOSED WORK, INCLUDING ANY
DEMOLITION WORK NOT SPECIFICALLY INDICATED ON THE PLANS.
4. ALL TREES DESIGNATED FOR REMOVAL SHALL BE MARKED BY THE CONTRACTOR AND VERIFIED BY THE ENGINEER PRIOR TO REMOVAL.
5. TREE REMOVAL SHALL INCLUDE REMOVAL OF THE EXISTING TREE ALONG WITH COMPLETE STUMP REMOVAL TO A DEPTH OF ONE FOOT
(1') BELOW EXISTING GRADE, PROPOSED GRADE, OR PROPOSED FEATURES, WHICHEVER IS LOWER.
GENERAL CONSTRUCTION NOTES
1. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR, AND MATERIALS, INCLUDING FLAGGERS, FOR THE MAINTENANCE AND
PROTECTION OF TRAFFIC (MPT) DURING THE PROJECT IN ACCORDANCE WITH THE PROJECT PLANS AND PENNDOT PUBLICATION 213
“TEMPORARY TRAFFIC CONTROL GUIDELINES”.
2. EACH CONTRACTOR AND SUBCONTRACTOR PERFORMING EXCAVATION OR DEMOLITION WORK FOR THIS PROJECT IS REQUIRED TO SUBMIT A CONSTRUCTION NOTIFICATION THROUGH THE PA ONE CALL SYSTEM NOT LESS THAN THREE (3) NOR MORE THAN TEN (10) BUSINESS DAYS IN ADVANCE OF BEGINNING EXCAVATION OR DEMOLITION WORK. EACH CONTRACTOR AND SUBCONTRACTOR ARE REQUIRED TO COMPLY WITH ALL PROVISIONS OF THE UNDERGROUND UTILITY LINE PROTECTION LAW (PA ACT 287 OF 1974, AS
AMENDED).
3. THE CONTRACTOR SHALL ANTICIPATE ENCOUNTERING GROUND WATER INFILTRATION INTO EXCAVATED AREAS DURING CONSTRUCTION. ALL COSTS ASSOCIATED WITH SIZING AND PROVIDING TEMPORARY BYPASS PUMPING AND/OR DEWATERING SHALL
BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
4. ALL FILL SHALL BE PLACED IN EIGHT INCH (8”) LAYERS AND THOROUGHLY COMPACTED TO THE SATISFACTION OF THE ENGINEER. IF
BORROW FILL IS REQUIRED, IT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER.
5. THE CONTRACTOR SHALL EXERCISE PARTICULAR CARE WHEN CONSTRUCTING OR RESURFACING PAVEMENT, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE FLOWING STORMWATER. ANY AREAS WHERE WATER IS IMPOUNDED SHALL
BE CORRECTED BY THE CONTRACTOR AT NO COST TO THE OWNER.
6. ALL PEDESTRIAN ACCESS TO SIDEWALKS AND STREETS, INCLUDING CROSSWALKS, CURB RAMPS, STREET FURNISHINGS, PEDESTRIAN SIGNALS, PARKING AND OTHER COMPONENTS OF PEDESTRIAN ACCESS PROPOSED IN BUILDINGS, SITES OR THE RIGHT-OF-WAY ARE TO BE IN ACCORDANCE WITH AMERICANS WITH DISABILITIES ACT (ADA) & ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES AND THE CURRENT PUBLIC RIGHTS-OF-WAY GUIDELINES PROPOSED BY THE ARCHITECTURAL AND TRANSPORTATION
BARRIERS COMPLIANCE BOARD (ACCESS BOARD).
7. ALL PLANTING LOCATIONS SHOWN ON THE PLANS ARE APPROXIMATE. FINAL LOCATIONS FOR ALL PLANTINGS SHALL BE MARKED BY
THE CONTRACTOR AND VERIFIED BY THE ENGINEER PRIOR TO PLANTING.
8. ALL CONSTRUCTION SPECIFICATIONS AND DETAILS NOT SHOWN SHALL BE IN ACCORDANCE WITH PENNDOT STANDARDS AS DETAILED
IN THE LATEST REVISIONS OF THE FOLLOWING:
a. PUBLICATION 35 (BULLETIN 15) “QUALIFIED PRODUCTS LIST FOR CONSTRUCTION”;
b. PUBLICATION 408/2020 ”SPECIFICATIONS”;
c. PUBLICATION 72M/2010 “STANDARDS FOR ROADWAY CONSTRUCTION”;
d. PUBLICATION 111 “TRAFFIC CONTROL - PAVEMENT MARKINGS AND SIGNING STANDARDS”;
e. PUBLICATION 213 “TEMPORARY TRAFFIC CONTROL GUIDELINES”.
INCLUDING ALL APPLICABLE BASELINE DOCUMENT CHANGES AND APPENDICES. THESE CONSTRUCTION SPECIFICATIONS AND DETAILS
MAY BE PURCHASED THROUGH THE PENNDOT SALES STORE AT:
P.O BOX 2028
HARRISBURG, PA 17105-2028
(TELEPHONE: 1-717-787-6746)
UTILITY NOTES
1. LOCATION OF EXISTING UTILITIES ARE APPROXIMATE AND MUST BE VERIFIED IN THE FIELD PRIOR TO THE START OF CONSTRUCTION.
2. CONTRACTORS PERFORMING EXCAVATION WORK MUST FOLLOW REQUIREMENTS OF THE REQUIREMENTS SET FORTH IN PA ACT 287
OF 1974, AS AMENDED BY ACT 50 OF 2017, LATEST REVISION, INCLUDING PARTICIPATING IN A PRE-CONSTRUCTION MEETING.
3. UNLESS NOTED OTHERWISE, THE APPROXIMATE DEPTH OF ALL EXISTING WATER MAIN IS ± 4 FEET.
4. UNLESS NOTED OTHERWISE, APPROXIMATE DEPTH OF ALL EXISTING GAS MAIN IS ± 3 FEET.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF THE UNDERGROUND AND SURFACE UTILITIES
AND STRUCTURES AT OR ADJACENT TO THE SITE OF CONSTRUCTION AND IT SHALL BE AT THEIR OWN EXPENSE TO REPAIR OR
REPLACE ANYTHING THAT THEY DAMAGE.
6. EXISTING SANITARY SEWER MAINS & LATERALS SHOWN MAY NOT BE ACCURATE DUE TO INCOMPLETE UTILITY INFORMATION.
CONTRACTOR IS RESPONSIBLE FOR LOCATING, CLEANING, JETTING, AND VACUUMING ALL EXISTING SANITARY SEWER LINES, INLET AND MANHOLE STRUCTURES. EXISTING CLEANOUTS AND SERVICE LATERALS SHALL BE REPLACED AS DIRECTED BY THE ENGINEER.
CONTRACTOR SHALL PREPARE SUBMITTAL UPON PROPER FIELD LOCATION AND INVERT VERIFICATION SHOWING REVISED SEWER
LAYOUT IF APPLICABLE.
7. THE LIMIT OF DISTURBANCE FOR ANY UTILITY TRENCH WITHIN AN EXISTING ASPHALT ROADWAY SHALL BE LIMITED TO THE OUTSIDE
DIAMETER OF THE UTILITY PLUS TWO FEET (O.D. + 2').
8. THE LAY DOWN AREA FOR THE EXCAVATED MATERIAL SHALL BE IMMEDIATELY ADJACENT TO THE UTILITY TRENCH AND SHALL BE
ISOLATED TO THE EXISTING ASPHALT ROADWAY SURFACE.
9. THE CONTRACTOR SHALL USE PENNDOT NO. 2A COARSE AGGREGATE FOR BACKFILL BENEATH ANY STRUCTURES OR PAVEMENT
AREAS, INCLUDING GRAVEL SURFACES.
10. THE CONTRACTOR MAY USE EXCAVATED MATERIALS FOR BACKFILL IN UNPAVED AREAS, UNLESS OTHERWISE DIRECTED BY THE
ENGINEER.
11. FOR ALL NEW WATER MAINS, THE MINIMUM PIPE COVER SHALL BE THREE AND A HALF FEET (3.5').
12. FOR ALL WATER MAIN CROSSINGS OF SANITARY MAINS, THE MINIMUM VERTICAL CLEARANCE SHALL BE ONE AND A HALF FEET (1.5').
13. FOR ALL UTILITY CROSSINGS, THE MINIMUM UNSUPPORTED VERTICAL CLEARANCE SHALL BE ONE AND A HALF FEET (1.5'). UTILITY
CROSSINGS WITH MINIMUM VERTICAL CLEARANCES LESS THAN 1.5' REQUIRE ADEQUATE SUPPORT AND APPROVAL OF THE ENGINEER.
14. ALL UTILITY CROSSINGS/OFFSETS SHALL INCLUDE COMPACTED STABILIZATION MATERIAL FOR FULL LENGTH OF CROSSING.
CONCRETE NOTES
1. UNLESS OTHERWISE NOTED, ALL CONCRETE SIDEWALK SHALL BE FIVE FEET (5') WIDE.
2. UNLESS OTHERWISE NOTED, ALL CONCRETE CURB RADII SHALL BE FIVE FEET (5').
3. EXPANSION JOINTS (A.K.A. ISOLATION JOINTS) SHALL BE INSTALLED IN CONCRETE CURB AND SIDEWALK AREAS EVERY FORTY FEET
(40') OR WHEREVER CONCRETE CURB OR SIDEWALK AREAS ADJOIN STRUCTURES (E.G. CURBS, BUILDINGS, UTILITY POLES, EXISTING
SIDEWALKS, ETC.).
4. SEPARATE PAYMENT WILL NOT BE MADE FOR PROVIDING EXPANSION JOINT MATERIAL FOR ALL CONCRETE WORK, BUT THE COST
SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
5. CONTRACTION JOINTS (A.K.A. CONTROL JOINTS) SHALL BE INSTALLED IN ALL CONCRETE CURB EVERY TEN FEET (10') AND IN SIDEWALK AREAS EVERY EIGHT FEET (8') OR THE WIDTH OF THE SIDEWALK, WHICHEVER IS LESS, EACH WAY. CONTRACTION JOINTS SHALL BE
SAWCUT OR HAND GROOVED INTO CONCRETE WITHIN 12 HOURS OF THE CONCRETE HARDENING.
6. REINFORCEMENT SHALL BE SECURED IN THE PROPER LOCATION IN THE FORMS WITH TIE WIRE OR OTHER BAR SUPPORT SYSTEM TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. STEEL REINFORCEMENT IN CONCRETE SHALL HAVE A MINIMUM COVER OF THREE INCHES (3”) WHEN CAST AGAINST THE EARTH AND TWO INCHES (2”) WHEN CAST IN REMOVABLE FORMS AND EXPOSED TO THE
EARTH OR WEATHER.
7. NO ADDITIONAL WATER SHALL BE ADDED TO CONCRETE.
8. ON FORMED CONCRETE SURFACES, THE CONTRACTOR SHALL CURE FINISHED CONCRETE BY APPLYING TWO (2) COATS OF A WHITE
PIGMENTED CURING COMPOUND (ASTM C 309, TYPE 2). THE FIRST COAT SHALL BE APPLIED IMMEDIATELY AFTER STRIPPING THE FORMS. THE SECOND COAT SHALL BE APPLIED IMMEDIATELY AFTER THE FIRST COAT HAS SET.
9. COLD WEATHER CONCRETE. IN ACCORDANCE WITH ACI 306R-16, THE CONTRACTOR SHALL PROVIDE ADDITIONAL PROTECTION WHEN
PLACING CONCRETE DURING COLD WEATHER, DEFINED AS 40°F OR BELOW:
a. THE CONTRACTOR SHALL ARANGE FOR COLD WEATHER CONCRETE EQUIPMENT AND MATERIALS SUCH AS TARPING OR BLANKETS
TO BE AT THE PROJECT SITE BEFORE COLD WEATHER IS LIKELY TO OCCUR.
b. FROZEN SUBGRADE MUST BE THAWED PRIOR TO THE PLACEMENT OF CONCRETE.
c. CURE AND PROTECT CONCRETE AGAINST DAMAGE FROM FREEZING FOR A MINIMUM PERIOD OF THREE (3) DAYS, UNLESS
OTHERWISE SPECIFIED. THE PROTECTION PERIOD MAY BE REDUCED TO TWO (2) DAYS IF ONE OR MORE OF THE FOLLOWING ARE IMPLEMENTED: (1) TYPE 3 PORTLAND CEMENT MEETING REQUIREMENTS OF ASTM C 150; (2) A STRENGTH ACCELERATING ADMIXTURE MEETING THE REQUIREMENTS OF ASTM C 494; OR (3) 100 LB/CY OF ADDITIONAL CEMENT.
PAVEMENT NOTES
1. AT THE END OF EACH WORKDAY, THE CONTRACTOR SHALL BACKFILL ANY EXCAVATED AREAS WITHIN ROADWAYS, INSTALL
TEMPORARY PAVEMENT RESTORATIONS AND REOPEN ROADWAYS FOR VEHICLE TRAFFIC. THE USE OF COLD PATCH MATERIAL OR STEEL PLATES ON LOCAL STREETS REQUIRES PRIOR AUTHORIZATION BY THE ENGINEER AND IS PROHIBITED ON STATE HIGHWAYS.
2. THE CONTRACTOR SHALL INVENTORY ALL EXISTING PAVEMENT STRIPING AND MARKINGS PRIOR TO MILLING.
3. THE CONTRACTOR SHALL REMOVE ANY TEMPORARY PAVEMENT RESTORATIONS AND INSTALL PERMANENT PAVEMENT RESTORATIONS
FOR ALL EXCAVATED AREAS PRIOR TO BEGINNING SAWCUTTING OR MILLING FOR PAVEMENT RESURFACING WORK.
4. THE CONTRACTOR SHALL VERIFY THE LIMITS OF PAVEMENT RESURFACING OR RECONSTRUCTION WORK WITH THE ENGINEER PRIOR
BEGINNING TO ASSOCIATED SAWCUTTING OR MILLING.
5. THE CONTRACTOR SHALL SAWCUT CLEAN JOINTS THROUGH EXISTING ASPHALT PAVEMENT TO FACILITATE NEW BUTT JOINTS. THE
CONTRACTOR SHALL MILL AN EIGHTEEN INCHES (18”) WIDTH OF THE EXISTING PAVEMENT BEYOND THE JOINT TO PROVIDE AN
OVERLAP OF NEW SURFACE COURSE ASPHALT PAVEMENT OVER EXISTING ASPHALT PAVEMENT.
6. AFTER MILLING ASPHALT PAVEMENT SURFACES, THE CONTRACTOR SHALL PROVIDE A FULLY LOADED TRI-AXLE DUMP TRUCK AND PERFORM A PROOF ROLL OF MILLED SURFACES WITH THE ENGINEER TO DETERMINE AREAS FOR BASE REPAIR. BASE REPAIRS SHALL
BE PERFORMED PRIOR TO INSTALLING SCRATCH, LEVELING OR WEARING COURSES.
7. THE CONTRACTOR SHALL ADJUST ALL EXISTING MANHOLES, UTILITY COVERS AND VALVE BOXES TO AN ELEVATION FIVE-EIGHTHS OF
AN INCH (5/8”) BELOW THE PROPOSED PAVEMENT SURFACE.
8. THE CONTRACTOR SHALL PAINT EXISTING VERTICAL SURFACES OF CURBS, STRUCTURES, GUTTERS, AND PAVEMENTS THAT WILL BE IN CONTACT WITH ASPHALT MIXTURES WITH A UNIFORM COATING OF EITHER EMULSIFIED ASPHALT, CONSISTING OF PENNDOT MATERIAL CLASS TACK OR HOT ASPHALT BINDER OF THE CLASS AND TYPE AS SPECIFIED IN SECTION 460 OF PENNDOT PUBLICATION 408.
CONTRACT NOTES
1. THE CONTRACTOR SHALL MAKE A PRE-CONSTRUCTION VIDEO OF THE PROJECT AREA BEFORE BEGINNING ANY CONSTRUCTION
ACTIVITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL EXISTING CONCRETE CURB AND SIDEWALK AREAS NOT SHOWN TO BE
REMOVED OR REPLACED. THE CONTRACTOR WILL BE RESPONSIBLE FOR COMPLETE REMOVAL AND REPLACEMENT OF ANY DAMAGED CURB OR SIDEWALK NOT DOCUMENTED PRIOR TO THE START OF CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
3. THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH OTHER PRIME CONTRACTORS FOR THIS PROJECT, IF APPLICABLE. IN ADDITION, THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH PRIME CONTRACTORS ON OTHER PROJECTS UNDER CONSTRUCTION NEAR THE PROJECT AREA. ANY COORDINATION ISSUES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. THERE WILL NOT BE ANY SEPARATE PAYMENT FOR THIS COORDINATION, BUT THE COST SHOULD BE INCLUDED IN THE
VARIOUS ITEMS OF THE PROPOSAL.
4. RECONSTRUCTION OF EXISTING MANHOLES AND INLETS, INCLUDING CONCRETE CAPS AND OTHER NECESSARY MODIFICATIONS TO ACCOMMODATE NEW INLET CONSTRUCTION, SHALL BE INCLUDED IN THE UNIT PRICE BID FOR INLETS AND MANHOLES OF THE VARIOUS
KINDS.
5. SEPARATE PAYMENT WILL NOT BE MADE FOR SAWCUTTING OF ANY KIND, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS
OF THE PROPOSAL.
6. SEPARATE PAYMENT WILL NOT BE MADE FOR STEEL TREE ROOT PROTECTION PLATES, BUT THE COST SHALL BE INCLUDED IN THE
VARIOUS ITEMS OF THE PROPOSAL.
7. SEPARATE PAYMENT WILL NOT BE MADE FOR THE REMOVAL, TEMPORARY STORAGE AND REINSTALLATION OF EXISTING SIGNAGE ALONG THE PROJECT AREA, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.
8. SEPARATE PAYMENT WILL NOT BE MADE FOR THE EXCAVATION OF ROCK.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TRANSPORTATION AND PROPER DISPOSAL OF ALL UNUSED MATERIAL EXCAVATED
FROM THE PROJECT SITE. PROPER DISPOSAL SHALL BE IN ACCORDANCE WITH PA DEP REQUIREMENTS.
10. CONTRACTOR SHALL RESTORE ALL EXISTING FEATURES DISTURBED DURING CONSTRUCTION (I.E. MAILBOXES, IRRIGATION SYSTEMS, LANDSCAPING, ETC.). ALL COSTS SHALL BE INCLUDED IN THE PRICE BID FOR SITE CLEARING.
11. THE CONTRACTOR SHALL ANTICIPATE GROUND WATER INFILTRATION INTO ALL OF THE COMBINED SEWER/STORM SEWER PIPES, INLETS AND MANHOLES WHEN PERFORMING THE VARIOUS TASKS ASSOCIATED WITH THIS PROJECT. ALL COSTS ASSOCIATED WITH THE TEMPORARY BYPASS PUMPING AND OR DEWATERING SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THE PROPOSAL.
12. SEPARATE PAYMENT WILL NOT BE MADE FOR EXCAVATION, DEWATERING, FITTINGS, PIPE BEDDING, SHEETING, BRACING, SHORING, INLET CONNECTIONS, TRAPS, AND SUITABLE BACKFILL MATERIAL INVOLVED IN ALL PIPE AND ASSOCIATED STRUCTURES REMOVAL, RECONSTRUCTION, AND INSTALLATION, BUT THE COST SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL REGARDLESS
OF DEPTH.
SITE SAFETY, CLEANLINESS & RESTORATION NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY ON THE PROJECT SITE AND FOR FOLLOWING ALL OSHA AND LOCAL SAFETY
STANDARDS.
2. THE CONTRACTOR SHALL ENSURE THAT THE SITE IS SECURE AT THE END OF EACH WORKDAY. ALL EQUIPMENT AND MATERIALS
SHOULD BE STORED NEATLY AND SECURELY. EXCAVATED AREAS SHALL BE BACKFILLED OR SECURED TO PREVENT ANY FALL HAZARD.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING PAVED SURFACES, INCLUDING SIDEWALKS, FREE AND CLEAR OF SEDIMENT
AND IN A BROOM SWEPT CONDITION WHEN OPEN TO PUBLIC USE. AT A MINIMUM, THE CONTRACTOR SHALL CLEAN PAVED SURFACES
AT THE END OF EACH WORKDAY AND WHEN DIRECTED BY THE ENGINEER.
4. THE ALL VEGETATED AREAS DISTRIBUTED DURING CONSTRUCTION SHALL BE TOPSOILED, SEEDED, FERTILIZED AND COVERED WITH STRAW MULCH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING AND/OR RE-SEEDING AS NECESSARY TO ENSURE
VEGETATIVE STABILIZATION.
5. ALL PAVED AND CONCRETE AREAS EXCAVATED OR DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITION
AT LEAST EQUAL TO THAT WHICH EXISTED PRIOR TO THE START OF CONSTRUCTION.
6. PRIOR TO FINAL PAYMENT, THE CONTRACTOR SHALL PERFORM FINAL CLEANING. FINAL CLEANING SHALL INCLUDE REMOVAL AND PROPER DISPOSAL OF ALL EXCESS CONSTRUCTION MATERIALS AND DEBRIS AS WELL AS CLEANING ALL PAVED SURFACES.
IRRIGATION PIPE
WATER SERVICE
COMMUNICATIONS SERVICE
TELEPHONE SERVICE
FIBER OPTIC SERVICE
ELECTRIC SERVICE
SANITARY SEWER PIPE $12"
SANITARY SEWER PIPE [12"
GAS SERVICE
STORM SEWER PIPE $12"
STORM SEWER PIPE [12"
SANITARY FORCE MAIN PIPE
OVERHEAD WIRE
WATER SHUT-OFF
WATER METER
WATER VALVE
WATER HYDRANT
WELL
YARD HYDRANT
METER PIT
GAS SHUT-OFF
GAS METER
GAS VALVE
GAS LINE MARKER
CLEANOUT
SEWER VENT
IRRIGATION CONTROL VALVE
IRRIGATION BOX
IRRIGATION CONTROL BOX
SPRINKLER HEAD
COMMUNICATIONS PEDESTAL
COMMUNICATIONS LINE MARKER
TELEPHONE PEDESTAL
TELEPHONE LINE MARKER
ELEC. BOX
ELEC. METER
ELEC. TRANSFORMER PAD
ELEC. VAULT
ELEC. LINE MARKER
MANHOLES
UTILITY POLE
GUY ANCHOR
ELEC. OUTLET
AREA DRAIN
LIGHTS
CONCRETE MONUMENT
PK / MAG NAIL / DRILL HOLE / SPIKE
STAKE
HUB
PIN W/ CAP
IRON PIPE
CROSS CUT
DRILL HOLE W/ WINGS
DISK
STONE
REBAR
BASELINE
CENTERLINE
EASEMENT
RIGHT-OF-WAY
BORING LOCATION
MONITORING WELL LOCATION
TEST PIT LOCATION
FRESHWATER WETLAND FLAG
FRESHWATER WETLAND LINE
EDGE OF WATER
STREAM CENTERLINE
DECIDUOUS TREE
SHRUBS / BUSH
EVERGREENS
STUMP
WOODS / TREE LINE
CROWS FOOT
IRON PIN
PROPERTY BOUNDARY
RAILROAD TRACKS
ADJACENT PROPERTY BOUNDARY
STATE BOUNDARY
MUNICIPAL / COUNTY BOUNDARY
FRESHWATER WETLAND BUFFER
WIRE FENCE
SPLIT RAIL FENCE
WOOD / VINYL FENCE
CHAIN-LINK FENCE
TOP OF BANK / DITCH
BOTTOM OF BANK / DITCH
FLOW LINE / SWALE
CONTOUR (MAJOR)
CONTOUR (MINOR)
TIME OF CONCENTRATION
ROADWAY GRADE
DRAINAGE FLOW
EDGE OF PAVEMENT
CURB
PAVEMENT / CONC. / SIDEWALK
LIMIT OF EXCAVATION
GUIDE RAIL
BOLLARD
MAILBOX
SIGNS
FLAG POLE
BENCH
PILE
TRAFFIC CONTROL BOX
TRAFFIC LIGHT
DEPT. OF TRANSPORTATION MANHOLE
STATE HIGHWAY DEPARTMENT
TYPICAL NORTH ARROW
BENCHMARK LOCATION
DETECTABLE WARNING SURFACE
TYPICAL STRIPING
ADA STRIPING
CALL BOX
OIL FILL
UNDERGROUND STORAGE TANK LID
RISER PIPE
UNKNOWN VALVE
VENT
VENT PIPE
SPOT GRADE
AERIAL TARGET
RAILROAD CROSSING BEACON
RAISED PAVEMENT MARKER
GRASS/SOD APR. APRON EL. ELEVATION PERF. PERFORATED SWL SINGLE WHITE LINE
ASB ASBESTOS CEMENT PIPE EX. EXISTING PC POINT OF CURVATURE SYL SINGLE YELLOW LINE
AFF ABOVE FINISHED FLOOR FFE FINISH FLOOR ELEVATION PI POINT OF INFLECTION TBA TO BE ABANDONED
ASB ASBESTOS FT FEET PT POINT OF TANGENCY TBR TO BE REMOVED
AL ALUMINUM E.B.,W.B,
N.B.,S.B.
EASTBOUND, WESTBOUND,
NORTHBOUND, SOUTHBOUND PSI POUNDS PER SQUARE INCH TC TOP OF CURB
BL BASELINE GL GUTTER LINE PK PARKER KAYLON MASONRY NAIL TEL TELEPHONE
BM BENCH MARK GR GRATE PROP. PROPOSED TEMP. TEMPORARY
BIT. BITUMINOUS GALV. GALVANIZED PVC POLYVINYL CHLORIDE PIPE TYP. TYPICAL
BLDG. BUILDING HW HEADWALL PVC POINT OF VERTICAL
CURVATURE UD UNDERDRAIN
BGS BELOW GROUND SURFACE HDPE HIGH DENSITY POLYETHYLENE PIPE PVI POINT OF VERTICAL
INTERSECTION UP UTILITY POLE
CL CENTERLINE INV. INVERT PVT POINT OF VERTICAL TANGENCY V VOLTS
CIP CAST IRON PIPE IP IRON PIN R RADIUS VAR. VARIES
CONC. CONCRETE IN INCHES RCP REINFORCED CONCRETE PIPE WM WATER METER
CMP CORRUGATED METAL PIPE JB JUNCTION BOX RMC RIGID METALLIC CONDUIT
CULV. CULVERT LSA LANDSCAPED AREA R.O.W. RIGHT OF WAY
CS CARBON STEEL LF LINEAR FEET R.R. RAILROAD
CF CUBIC FEET LST LANDSCAPE TIE RTE. ROUTE
CY CUBIC YARDS LOM LIMIT OF MILLING SAN. SANITARY
CMU CONCRETE MASONRY UNIT LOP LIMIT OF PAVING SS STAINLESS STEEL
D.C. DEPRESSED CURB MB MAILBOX SWK. SIDEWALK
DH DRILL HOLE MAX. MAXIMUM SHD STATE HIGHWAY DEPARTMENT
DIA. DIAMETER MIN. MINIMUM SHLD. SHOULDER
DIP DUCTILE IRON PIPE MH MANHOLE STY. STORY
DWY DRIVEWAY NO. NUMBER STA. STATION
DYL DOUBLE YELLOW LINE N.T.S. NOT TO SCALE
P PIPE
HEADWALL W/ WINGS
HEADWALL
INLET TYPE M
INLET TYPE C
INLET TYPE DOUBLE M
LE
G
EN
D
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_B uc ks \0
3_ Ya rd le y\ T\
T0
_2
6_ N or th
M ai n St
U ni ve rs ity
D r D ra in ag e
R ep la ce m en t\0 2_
D es ig n_ th ru
_C on tra ct s\
_C
AD
D \0
2_ M un i\D
W G
\P A0
3T
4-
ED
Q .d w g
/1
8/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
PROFESSIONAL ENGINEER LIC. NO. PE-0055338-E
CHRISTOPHER J. FAZIO
DATE:
WEB ADDRESS : RVE.COM
(267) 394-4500
LOWER MAKEFIELD CORPORATE
YARDLEY, PA 19067
REMINGTON
& VERNICK
ENGINEERS
1010 STONY HILL ROAD, SUITE 175
CENTER NORTH CAMPUS
· Excellence Innovation Service·
JMB MEW CJF
of 5-26-2026
PA091593T004
AS NOTED
YA
R
D
LE
Y
BO
R O
U G
H
YA
R
D
LE
Y
BO
R O
U G
H
BU
C
KS
C O
U N
TY
PE
N N
SY
LV
AN
IA
N . M
AI
N
S
TR
EE
T
U
N
IV
ER
SI
TY
D
R
IV
E
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
PH
AS
E
.0
.4
.2
.9
.7
SI
TE
U
TI
LI
TY
P
LA
N
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_B uc ks \0
3_ Ya rd le y\ T\
T0
_2
6_ N or th
M ai n St
U ni ve rs ity
D r D ra in ag e
R ep la ce m en t\0 2_
D es ig n_ th ru
_C on tra ct s\
_C
AD
D \0
2_ M un i\D
W G
\P A0
3T
4- C
.d w g
/1 8/
1:
:5
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
PROFESSIONAL ENGINEER LIC. NO. PE-0055338-E
CHRISTOPHER J. FAZIO
DATE:
WEB ADDRESS : RVE.COM
(267) 394-4500
LOWER MAKEFIELD CORPORATE
YARDLEY, PA 19067
REMINGTON
& VERNICK
ENGINEERS
1010 STONY HILL ROAD, SUITE 175
CENTER NORTH CAMPUS
· Excellence Innovation Service·
JMB MEW CJF
of 5-26-2026
PA091593T004
AS NOTED
YA
R
D
LE
Y
BO
R O
U G
H
YA
R
D
LE
Y
BO
R O
U G
H
BU
C
KS
C O
U N
TY
PE
N N
SY
LV
AN
IA
N . M
AI
N
S
TR
EE
T
U
N
IV
ER
SI
TY
D
R
IV
E
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
PH
AS
E
0 20' 40'
1 INCH =
GRAPHIC SCALE
20 FT.
60'
TO BE CONSTRUCTED
ITEM
NO. DESCRIPTION UNIT
PLAN
QUANTITY
AS-BUILT
QUANTITY
4 36" CLASS IV RCP LF 181
5 CONNECTION TO EXISTING
STRUCTURES
EA 1
6 CAST-IN-PLACE TYPE D ENDWALL LS 1
7 CLEAR EXISTING OUTFALL OF
SEDIMENT AND DEBRIS
SY 60
8 TREE REMOVAL, 15" DIA. EA 1
9 PERMANENT PAVEMENT
RESTORATION
SY 151
10 CONCRETE SIDEWALK SY 5
12 DCED PROJECT SIGN EA 1
14 CLEAN AND TELEVISE EXISTING
STORM SEWER SYSTEM
LS 1
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_B uc ks \0
3_ Ya rd le y\ T\
T0
_2
6_ N or th
M ai n St
U ni ve rs ity
D r D ra in ag e
R ep la ce m en t\0 2_
D es ig n_ th ru
_C on tra ct s\
_C
AD
D \0
2_ M un i\D
W G
\P A0
3T
4- D
ET
.d w g
/1
8/
1:
:5
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
PROFESSIONAL ENGINEER LIC. NO. PE-0055338-E
CHRISTOPHER J. FAZIO
DATE:
WEB ADDRESS : RVE.COM
(267) 394-4500
LOWER MAKEFIELD CORPORATE
YARDLEY, PA 19067
REMINGTON
& VERNICK
ENGINEERS
1010 STONY HILL ROAD, SUITE 175
CENTER NORTH CAMPUS
· Excellence Innovation Service·
JMB MEW CJF
of 5-26-2026
PA091593T004
AS NOTED
YA
R
D
LE
Y
BO
R O
U G
H
YA
R
D
LE
Y
BO
R O
U G
H
BU
C
KS
C O
U N
TY
PE
N N
SY
LV
AN
IA
N . M
AI
N
S
TR
EE
T
U
N
IV
ER
SI
TY
D
R
IV
E
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
PH
AS
E
An Activity of:
THE COMMONWEALTH OF PENNSYLVANIA,
COMMONWEALTH FINANCING AUTHORITY
CONTRACTOR:
(CONTRACTOR'S NAME)
N. MAIN STREET & UNIVERSITY DRIVE
STORMWATER IMPROVEMENTS - PHASE 1
ENGINEER:
BOROUGH OF YARDLEY
REMINGTON
& VERNICK
ENGINEERS
THIS PROJECT WAS FINANCED IN PART BY THE GRANT FROM THE
COMMONWEALTH OF PENNSYLVANIA, COMMONWEALTH FINANCING AUTHORITY
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
Z:
\S ha re d\ 1_
Pr oj ec ts
\0 _L oc _G ov \P
A\
_B uc ks \0
3_ Ya rd le y\ T\
T0
_2
6_ N or th
M ai n St
U ni ve rs ity
D r D ra in ag e
R ep la ce m en t\0 2_
D es ig n_ th ru
_C on tra ct s\
_C
AD
D \0
2_ M un i\D
W G
\P A0
3T
4- D
ET
.d w g
/1
8/
1:
:0
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
PROFESSIONAL ENGINEER LIC. NO. PE-0055338-E
CHRISTOPHER J. FAZIO
DATE:
WEB ADDRESS : RVE.COM
(267) 394-4500
LOWER MAKEFIELD CORPORATE
YARDLEY, PA 19067
REMINGTON
& VERNICK
ENGINEERS
1010 STONY HILL ROAD, SUITE 175
CENTER NORTH CAMPUS
· Excellence Innovation Service·
JMB MEW CJF
of 5-26-2026
PA091593T004
AS NOTED
YA
R
D
LE
Y
BO
R O
U G
H
YA
R
D
LE
Y
BO
R O
U G
H
BU
C
KS
C O
U N
TY
PE
N N
SY
LV
AN
IA
N . M
AI
N
S
TR
EE
T
U
N
IV
ER
SI
TY
D
R
IV
E
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
PH
AS
E
SECTION
PLAN
| Sheets and Views |
| 1 TITLE |
| 2 GENERAL NOTES & DISTRIBUTION OF QUANTITIES |
| 3 LEGEND |
| 4 SITE & UTILITY PLAN |
| 5 CONSTRUCTION DETAILS - 1 |
| 6 CONSTRUCTION DETAILS - 2 |
File details come from the government source that posted it. Updated .