5Metal Sales r-panel-ctr-2015.pdf
PDF 234 KB Posted
- Attached to
- FY16, PMAA, RMCR, shade Shelters
- Solicitation number
- IFB1 PMAA 2016000114 3
- Issued by
- Larimer County, Colorado
About this file
This is a technical reference document for Metal Sales' R-Panel, an architectural commercial and industrial wall panel system. The R-Panel is a 36-inch coverage exposed fastened metal building wall system available in multiple configurations and finishes, including PVDF, MS Colorfast45, and Acrylic Coated Galvalume with corrosion protection options ranging from AZ55 to G90 per ASTM standards. The panel is offered in standard gauges of 26 and 24 gauge, with 22 gauge as an optional specification, featuring a trapezoidal rib on 12-inch centers with 11/4-inch rib height. Panel lengths range from a minimum of 5 feet to a maximum of 45 feet recommended. The document includes comprehensive technical specifications suitable for both open framing and solid substrate applications across architectural, commercial, and industrial sectors.
The R-Panel has achieved multiple testing and approvals including UL 2218 Impact Resistance Class 4, UL 790 Fire Resistance Rating Class A, UL 580 Uplift Resistance Class 90, Texas Wind Storm Evaluation certifications, 2010 FBC Approvals for Florida, and Miami-Dade County Florida NOA 09-0113.01 for wall applications. The document provides detailed section properties, allowable uniform live loads in psf for various fastener spacings from 2 to 7 feet, and fastening specifications for both wood and steel applications using #10-14 XL wood screws or #12-14 XL self-drilling screws for panel fasteners. Metal Sales maintains distribution centers across 19 locations nationwide, including facilities in major markets such as California, Texas, Florida, and Minnesota, with contact information and technical specifications available through their website at metalsales.us.com.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3Appendix B-Shade Shelters_Island Acres.pdf | ||
| 2Appendix A - GRCs Sep 1996.pdf | ||
| 1Island Acres Shade Shelters.pdf | ||
| BID BOND.pdf | ||
| 4aDivision II Specifications.pdf | ||
| PNCI Question.docx | DOCX document | |
| 6Shade Shelter-photos.pdf | ||
| Island Acres SIGN-IN.PDF | ||
| BID BOND FORM.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C o n d e n s e d T e c h n i c a l R e f e r e n c e
OPEN FRAMING OR
SOLID SUBSTRATE
ARCHITECTURAL
COMMERCIAL
INDUSTRIAL
PANEL
36"
COVERAGE
WALL
PANELEXPOSED
FASTENED
Finishes: PVDF, MS Colorfast45® and Acrylic Coated Galvalume®
Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume®
AZ50 per ASTM A 792 for painted Galvalume®
G90 per ASTM A 653 for Galvanized Gauges: 26 ga and 24 ga standard; 22 ga optional 36" panel coverage, 11/4" rib height Panel Length: Minimum: 5'; Maximum: 45' recommended Exposed fastened metal building wall system Trapezoidal rib on 12" centers
PANEL OVERVIEW
R-PANEL
UL 2218 Impact Resistance - Class 4 UL 790 Fire Resistance Rating - Class A, per building code UL 263 Fire Resistance Rating - per assembly UL 580 Uplift Resistance - Class 90 Construction: #161 Texas Wind Storm - Evaluation RC-198, RC-279 2010 FBC Approvals - FL9482.4 and FL14645.11 Miami-Dade County, Florida NOA 09-0113.01 - Wall
TESTING AND APPROVALS
C 12"
11/4"
35/16"
21/16" 4"
36" Coverage
3/4"
1"
17/16" ryans Rectangle
M
S
R
/1 -2
C o n d e n s e d T e c h n i c a l R e f e r e n c e
Anchorage, AK 866.640.7663 Bay City, MI 888.777.7640 Deer Lake, PA 800.544.2577 Denver, CO 800.289.7663
Detroit Lakes, MN 888.594.1394 Fontana, CA 800.782.7953 Fort Smith, AR 877.452.3915 Independence, MO 800.747.0012
Jacksonville, FL 800.394.4419 Jefferson, OH 800.321.5833 Mocksville, NC 800.228.6119 Nashville, TN 800.251.8508 Rock Island, IL 800.747.1206 Rogers, MN 800.328.9316
Seattle, WA 800.431.3470 Sellersburg, IN 800.999.7777 Sioux Falls, SD 888.902.8320 Spokane, WA 800.572.6565 Temple, TX 800.543.4415 Woodland, CA 800.759.6019 metalsales.us.com
Overdriven fasteners will cause panel distortions.
Fasteners should extend 1/2" or more past the inside face of the support material.
Thick panels (ex. 18 ga) or supports (ex. 1/2" steel) may require predrilling of holes for screws.
Panel Fastener:
Attaching to Wood:
#10-14 XL Wood Screw
Attaching to Steel:
#12-14 XL Self Drilling Screw
Trim Fastener:
1/4"-14 x 7/8" XL Stitch Screw
FASTENER INFORMATION
R-PANEL
| 1. | Theoretical section properties have been calculated per AISI 2007 'North American Specification for the Design of Cold-Formed Steel Structural Members'. |
| Ixx and Sxx are effective section properties for deflection and bending. | |
| 2. | Allowable load is calculated in accordance with AISI 2007 specifications considering bending, shear, combined bending and shear and deflection. Allowable |
| load considers the 3 or more equal spans condition. Allowable load does not address web crippling, fasteners, support material or load testing. Panel weight | |
| is not considered. | |
| 3. | Deflection consideration is limited by a maximum deflection ratio of L/180 of span. |
| 4. | Allowable loads do not include a 1/3 stress increase for wind. |
ALLOWABLE UNIFORM LIVE LOADS, psf For various fastener spacings
2’ 3’ 4’ 5’ 6’ 7’ 2’ 3’ 4’ 5’ 6’ 7’
SECTION PROPERTIES
Bottom in Compression Width in Yield ksi
36 80
36 50
36 50
Ga
Sxx in3/ft
Ixx in4/ft
Weight psf
0.80
1.05
1.38
Top in Compression
Sxx in3/ft
Ixx in4/ft
Inward Load
Outward Load
0.0357 0.0357 0.0303 0.0448 245 123 73 48 34 23 211 102 60 39 27 20
0.0543 0.0560 0.0437 0.0600 317 149 85 55 38 28 300 140 80 52 36 26
0.0780 0.0822 0.0613 0.0798 437 201 115 74 51 38 449 207 118 76 53 38
ATTACHMENT DETAIL
FASTENING PATTERNS
Panel Fastener
End of Panel
Field of Panel
Panel Fastener
Panel Fastener ryans Rectangle ryans Rectangle