About this file

This is a technical reference document for Metal Sales' R-Panel, an architectural commercial and industrial wall panel system. The R-Panel is a 36-inch coverage exposed fastened metal building wall system available in multiple configurations and finishes, including PVDF, MS Colorfast45, and Acrylic Coated Galvalume with corrosion protection options ranging from AZ55 to G90 per ASTM standards. The panel is offered in standard gauges of 26 and 24 gauge, with 22 gauge as an optional specification, featuring a trapezoidal rib on 12-inch centers with 11/4-inch rib height. Panel lengths range from a minimum of 5 feet to a maximum of 45 feet recommended. The document includes comprehensive technical specifications suitable for both open framing and solid substrate applications across architectural, commercial, and industrial sectors.

The R-Panel has achieved multiple testing and approvals including UL 2218 Impact Resistance Class 4, UL 790 Fire Resistance Rating Class A, UL 580 Uplift Resistance Class 90, Texas Wind Storm Evaluation certifications, 2010 FBC Approvals for Florida, and Miami-Dade County Florida NOA 09-0113.01 for wall applications. The document provides detailed section properties, allowable uniform live loads in psf for various fastener spacings from 2 to 7 feet, and fastening specifications for both wood and steel applications using #10-14 XL wood screws or #12-14 XL self-drilling screws for panel fasteners. Metal Sales maintains distribution centers across 19 locations nationwide, including facilities in major markets such as California, Texas, Florida, and Minnesota, with contact information and technical specifications available through their website at metalsales.us.com.

View the file

Other files

File Type Posted
3Appendix B-Shade Shelters_Island Acres.pdf PDF
2Appendix A - GRCs Sep 1996.pdf PDF
1Island Acres Shade Shelters.pdf PDF
BID BOND.pdf PDF
4aDivision II Specifications.pdf PDF
PNCI Question.docx DOCX document
6Shade Shelter-photos.pdf PDF
Island Acres SIGN-IN.PDF PDF
BID BOND FORM.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C o n d e n s e d T e c h n i c a l R e f e r e n c e

OPEN FRAMING OR

SOLID SUBSTRATE

ARCHITECTURAL

COMMERCIAL

INDUSTRIAL

PANEL

36"

COVERAGE

WALL

PANELEXPOSED

FASTENED

Finishes: PVDF, MS Colorfast45® and Acrylic Coated Galvalume®

Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume®

AZ50 per ASTM A 792 for painted Galvalume®

G90 per ASTM A 653 for Galvanized Gauges: 26 ga and 24 ga standard; 22 ga optional 36" panel coverage, 11/4" rib height Panel Length: Minimum: 5'; Maximum: 45' recommended Exposed fastened metal building wall system Trapezoidal rib on 12" centers

PANEL OVERVIEW

R-PANEL

UL 2218 Impact Resistance - Class 4 UL 790 Fire Resistance Rating - Class A, per building code UL 263 Fire Resistance Rating - per assembly UL 580 Uplift Resistance - Class 90 Construction: #161 Texas Wind Storm - Evaluation RC-198, RC-279 2010 FBC Approvals - FL9482.4 and FL14645.11 Miami-Dade County, Florida NOA 09-0113.01 - Wall

TESTING AND APPROVALS

C 12"

11/4"

35/16"

21/16" 4"

36" Coverage

3/4"

1"

17/16" ryans Rectangle

M

S

R

/1 -2

C o n d e n s e d T e c h n i c a l R e f e r e n c e

Anchorage, AK 866.640.7663 Bay City, MI 888.777.7640 Deer Lake, PA 800.544.2577 Denver, CO 800.289.7663

Detroit Lakes, MN 888.594.1394 Fontana, CA 800.782.7953 Fort Smith, AR 877.452.3915 Independence, MO 800.747.0012

Jacksonville, FL 800.394.4419 Jefferson, OH 800.321.5833 Mocksville, NC 800.228.6119 Nashville, TN 800.251.8508 Rock Island, IL 800.747.1206 Rogers, MN 800.328.9316

Seattle, WA 800.431.3470 Sellersburg, IN 800.999.7777 Sioux Falls, SD 888.902.8320 Spokane, WA 800.572.6565 Temple, TX 800.543.4415 Woodland, CA 800.759.6019 metalsales.us.com

Overdriven fasteners will cause panel distortions.

Fasteners should extend 1/2" or more past the inside face of the support material.

Thick panels (ex. 18 ga) or supports (ex. 1/2" steel) may require predrilling of holes for screws.

Panel Fastener:

Attaching to Wood:

#10-14 XL Wood Screw

Attaching to Steel:

#12-14 XL Self Drilling Screw

Trim Fastener:

1/4"-14 x 7/8" XL Stitch Screw

FASTENER INFORMATION

R-PANEL

1.Theoretical section properties have been calculated per AISI 2007 'North American Specification for the Design of Cold-Formed Steel Structural Members'.
Ixx and Sxx are effective section properties for deflection and bending.
2.Allowable load is calculated in accordance with AISI 2007 specifications considering bending, shear, combined bending and shear and deflection. Allowable
load considers the 3 or more equal spans condition. Allowable load does not address web crippling, fasteners, support material or load testing. Panel weight
is not considered.
3.Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4.Allowable loads do not include a 1/3 stress increase for wind.

ALLOWABLE UNIFORM LIVE LOADS, psf For various fastener spacings

2’ 3’ 4’ 5’ 6’ 7’ 2’ 3’ 4’ 5’ 6’ 7’

SECTION PROPERTIES

Bottom in Compression Width in Yield ksi

36 80

36 50

36 50

Ga

Sxx in3/ft

Ixx in4/ft

Weight psf

0.80

1.05

1.38

Top in Compression

Sxx in3/ft

Ixx in4/ft

Inward Load

Outward Load

0.0357 0.0357 0.0303 0.0448 245 123 73 48 34 23 211 102 60 39 27 20

0.0543 0.0560 0.0437 0.0600 317 149 85 55 38 28 300 140 80 52 36 26

0.0780 0.0822 0.0613 0.0798 437 201 115 74 51 38 449 207 118 76 53 38

ATTACHMENT DETAIL

FASTENING PATTERNS

Panel Fastener

End of Panel

Field of Panel

Panel Fastener

Panel Fastener ryans Rectangle ryans Rectangle