Atlanta Garage In-Ground Hoist Replacement – Construction Design Documents
This document set comprises the Final Submittal Phase 500 design and construction drawings for the Michigan Department of Transportation (DTMB/MDOT) Atlanta Garage In-Ground Hoist Replacement project located in Atlanta, Michigan. The project involves the replacement of an existing in-ground hoist system within a 22,000 square foot single-story maintenance garage facility owned by the State of Michigan. The scope includes demolition of existing monorail and hoist equipment, installation of new structural steel, concrete pit work, hydraulic and compressed air piping systems, and associated electrical and control systems. The facility is classified as S-1 storage occupancy with B accessory use under the 2021 Michigan Building Code and 2021 Michigan Rehabilitation Code for Existing Buildings. The project is designed by Sidock Group, Inc. (Architectural & Structural Engineering) and Matrix Consulting Engineers (Consulting Engineer), with specifications prepared in accordance with applicable building codes, AISC standards, ACI standards, and industry best practices.
The design includes comprehensive structural, mechanical, electrical, and plumbing specifications addressing site conditions, new concrete slab work with reinforcement at the pit location, structural steel modifications to the existing monorail system, removal and relocation of electrical and HVAC systems, and installation of new hydraulic and pneumatic control systems. Construction documentation indicates existing construction will largely remain in place, with demolition limited to specific hoist components and affected utilities. Special inspections are required for structural steel work, concrete construction, and soil preparation per Michigan Building Code Table 1705. The project contains standard commercial construction provisions including performance bonds, labor and material payment bonds, and compliance with MIOSHA regulations and local building official requirements. Record drawings and as-built documentation will be required upon completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LAKE
MICHIGAN
LAKE
SUPERIOR
LAKE
ERIE
LAKE
HURON
SCALE:
N
LOCATION MAP
NO SCALE
PROJECT INFORMATION
SITE AREA:
EXISTING: N/A- EXIST FACILITY
ZONING:
EXISTING= N/A, STATE OWNED
PARKING: EXIST.- NO INCREASE IN PARKING PROPOSED
SITE DATA
GROSS EXISTING = 22,000 S.F.
HEIGHT = 1 STORY, EXISTING
BUILDING DATA
FINAL SUBMITTAL PHASE 500
DTMB MDOT
ATLANTA GARAGE HOIST INSTALLATION
ATLANTA, MICHIGAN
DTMB: FILE/INDEX NO.: 591/25100.RLO
GENERAL
SHEET INDEX
ARCHITECTURAL
A-1 DEMOLITION PLAN, PLAN, ENLARGED PLAN, REFLECTED CEILING PLAN, NOTES
A-2 LIFT INSTALL PLANS, CERTIFICATION
CS-0 COVER SHEET
CS-1 ABBREVIATIONS, LIFE SAFETY PLAN, DRAWING LEGEND
CS-2 MOUNTING HEIGHTS, SIGNAGE & CONTROL NOTES
CODE INFORMATION
BUILDING CODE: 2021 MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS/ 2021 MICHIGAN BUILDING CODE
AND 2012 NFPA 101 LIFE SAFETY CODE (AS APPLICABLE)
CONSTRUCTION CLASSIFICATION
MBC/NFPA: VB/V000 (NOT SPRINKLERED, EXISTING)
OCC. GROUP(S): EXISTING S-1 OCCUPANCY ( B ACCESSORY OCC.)
PLUMBING
P100 PLUMBING SYMBOLS, NOTES & ABBREVIATIONS
P101 PLUMBING SPECIFICATIONS
P400 BELOW FLOOR PLAN - PLUMBING NEW
P401 FLOOR PLAN - PLUMBING NEW
ELECTRICAL
E100 ELECTRICAL - SYMBOLS, ABBREVIATIONS & NOTES
E200 ELECTRICAL - SHEET SPECIFICATIONS
E300 ELECTRICAL - FLOOR PLAN - DEMOLITION
E500 ELECTRICAL - FLOOR PLAN - POWER AND ONE LINE DIAGRAM
E900 ELECTRICAL - PANEL SCHEDULES
C O
VE
R
S H
EE
T
CS
-0
ARCHITECTURAL & STRUCTURAL ENGINEERING: SIDOCK GROUP, INC.
757 S. WISCONSIN AVE., GAYLORD MI 49735, (989) 734-8400
CONSULTING ENGINEER: MATRIX CONSULTING ENGINEERS
1601 E. CESAR E. CHAVEZ AVE., LANSING, MI 48906 (517) 487-2511
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2024
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
BBG
G D
S, G
G G
G
.0 6.
1/
0.
R
LO
.1 5.
STRUCTURAL
S-000 STRUCTURAL GENERAL NOTES
S-001 STRUCTURAL GENERAL NOTES
S-1 STRUCTURAL PLANS AND DETAILS
S-2 STRUCTURAL MONORAIL PLAN AND DETAIL
@ AT
M MATCH
ACC. ACCESS
MEZZ. MEZZANINE
NO. NUMBER
B.F. BARRIER FREE
B.O.D. BOTTOM OF DECK
G GUTTER ELEVATION
BOT. BOTTOM
BRG. BEARING
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OHD. OVERHEAD DOOR
COMP. COMPACTED
PEMB. PRE-ENGINEERED METAL BUILDING
CONC. CONCRETE
PERIM. PERIMETER
PLAM. PLASTIC LAMINATE
ID. INSIDE DIAMETER
P.S.F. POUNDS PER SQUARE FOOT
INV. INVERT
P.S.I. POUNDS PER SQUARE INCH
INSUL. INSULATED
R RADIUS OR RISER
ELEV. ELEVATOR
EQ. EQUAL
R.O. ROUGH OPENING
EWC. ELECTRIC WATER COOLER
LAV. LAVATORY
L.L. LIVE LOAD
L.L.H. LONG LEG HORIZONTAL
L.L.V. LONG LEG VERTICAL
CLR. CLEAR
CLG. CEILING
CL. CLASS
COL. COLUMN
E EAST
SQ. FT. SQUARE FEET / FOOT
ST. STAIN
STL. STEEL
THRESH. THRESHOLD
U.N.O. UNLESS NOTED OTHERWISE
VCT.
VERT. VERTICAL
W/ WITH
GYP. BD./ GB/ GWB GYPSUM WALLBOARD SYSTEMS
IOHD. INSULATED OVERHEAD DOOR
IRD. INSULATED ROLLING DOOR
MT. MARBLE THRESHOLD
PRE-FIN. PRE-FINISHED
TYP. TYPICAL
CL
~ APPROXIMATELY
B/C BACK OF CURB OR
BOTTOM CHORD
B/B BACK TO BACK
B/ BOTTOM OF
B.O.C. BACK OF CURB
B.O.P. BOTTOM OF PIPE
C.B. CATCH BASIN
CMP. CORRUGATED METAL PIPE
C.O. CLEAN OUT
CPPP. CORRUGATED PERFORATED PLASTIC PIPE
W
U.P. UTILITY POLE
TD. TRENCH DRAIN
T/W TOP OF WALK
T/P TOP OF PAVEMENT
T/C TOP OF CURB OR
TOP CHORD
T/ TOP OF
IN. INCH / INCHES
GALV. GALVANIZE (D)
LVR. LOUVER
MH. MANHOLE
MAX. MAXIMUM
N NORTH
P.C. POINT OF CURVATURE
PT./ P PAINT (EXTERIOR, INTERIOR, TRANSPARENT
FINISHES)
PIV. POST INDICATOR VALVE
PROP. PROPOSED
E.C. EXPOSED CONCRETE
E.S. END SECTION
R.O.W. RIGHT OF WAY
RL. RAIL (ING)
RCP. REINFORCED CONCRETE
SC. SOLID CORE
S SOUTH
SFGL. SAFETY GLASS
SAN. FM. SANITARY FORCE MAIN
STW. STORM SEWER
EL. ELEVATION
INL. INLET
CENTER LINE
C.P. CENTER POINT
B.O.W. BOTTOM OF WALL
A.F.F. ABOVE FINISHED FLOOR
ABV. ABOVE
A.S.C. ABOVE SUSPENDED CEILING
ACFL. ACCESS FLOOR
A.P. ACCESS PANEL
ACPL. ACOUSTICAL PLASTER
A.C.T./ AT ACOUSTICAL CEILING TILE
ACP. ACRYLIC PLASTIC
A/C AIR CONDITIONING
ADDN'L ADDITIONAL
ADH. ADHESIVE
ADJ. ADJACENT
ADJT. ADJUSTABLE
AGG. AGGREGATE
A.B. ANCHOR BOLT
A.C.U. AIR CONDITIONING UNIT
ANC. ANCHOR, ANCHORAGE
ADDN. ADDITION
ANOD. ANODIZED
A.H.U. AIR HANDLING UNIT
ALT. ALTERNATE
AL. ALUMINUM
APT. APARTMENT
APPROX.APPROXIMATE
ARCH. ARCHITECT (URAL)
A.D. AREA DRAIN
ASB. ASBESTOS
ASPH. ASPHALT
A.T. ASPHALT TILE
A.C.M. ASBESTOS CONTAINING MATERIAL
AUTO AUTOMATIC
B.P. BACK PLASTER (ED)
BALC. BALCONY
BSMT. BASEMENT
B. BATHROOM
BPL. BEARING PLATE
BJT. BED JOINT
BR. BEDROOM
BM. BENCHMARK OR BEAM
BEL. BELOW
BVL. BEVELED
BIT. BITUMINOUS
BLK. BLOCK
BLKG. BLOCKING
BD. BOARD
B.S. BOTH SIDES
B.W. BOTH WAYS
B.O.F. BOTTOM OF FOOTING
BLVD. BOULEVARD
BRCG. BRACING
BC. BRICK
BRZ. BRONZE
BLDG. BUILDING
B.L. BUILDING LINE
B.U.R. BUILT UP ROOFING
BLKHD.BULKHEAD
BBD. BULLETIN BOARD
CAB. CABINET
CAD. CADMIUM OR CAD
CPT. CARPET TILE
CSMT. CASEMENT
C.I. CAST IRON
C.I.P.C. CAST IN PLACE CONCRETE
C.S. CAST STONE
CLK. CALK (ING) OR CAULK (ING)
CHT. CEILING HEIGHT
CEM. CEMENT
CPPL. CEMENT PLASTER (PORTLAND)
CM. CENTIMETER (S)
CER. CERAMIC
C.T. CT CERAMIC TILE (FLOOR, BASE, AND WALL)
C.M.T. CERAMIC MOSAIC TILE
CHBD. CHALK BOARD
CHAM. CHAMFER
CR. CHROMIUN
CIR. CIRCLE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS OR CONTINUATION
CONTR. CONTRACT (OR)
C.L.L. CONTRACT LIMIT LINE
CNJ.
CONTROL JOINT
CPR. COPPER
C.G. CORNER GUARD
CLR. CLEAR (ANCE)
COMB. COMBINATION
COMPT.COMPARTMENT
COMPO.COMPOSITION (COMPOSITE)
COMP. COMPRESS (ED) (ION) (IBLE)
CORID. CORRIDOR
COORD. COORDINATE (ION)
CIRC. CIRCUMFERENCE
CLS. CLOSURE
CORR. CORRUGATED
CTR. COUNTER
CFL. COUNTER FLASHING
C.S. COUNTER SINK
CTSK. COUNTERSUNK
CRS. COURSE (S)
CTYD. COURTYARD
CFT. CUBIC FOOT
CYD. CUBIC YARD
C.J.
CENTER TO CENTERC/C
CERT. CERTIFIED
DEMOUNTABLEDMT.
DEPRESSEDDEP.
DETAILDET.
DIAGONALDIAG.
DIAMETERDIA.
DIMENSION (S)DIM.
DISPENSERDSP.
DIVISIONDIV.
DOUBLEDBL.
DOUBLE ACTIONDBLA.
DOUBLE HUNGDBLH.
DOVETAIL ANCHORDTA.
DOVETAIL ANCHOR SETDTS.
DOWEL (S)DWL.
DOWNDN.
CRG. CROSS GRAIN
DOWNSPOUTDS.
DRAIND.
DRAIN BOARDDRB.
DRAWERDWR.
DRINKING FOUNTAIND.F.
DUMB WAITERD.W.
DOOR HEADERD.H.
DOOR JAMBD.J.
DRAWINGDWG.
DOOR OPENINGD.O.
EACHEA.
EACH FACEE.F.
EACH WAYE.W.
ELECTRIC (AL)ELEC.
ELECTRICAL PANELE.P.
ENC. ENCLOSE (URE)
EQUIP. EQUIPMENT
ESC. ESCALATOR
EMER. EMERGENCY
EST. ESTIMATE
EXCA. EXCAVATE
EXH. EXHAUST
EXIST./ EX. EXISTING
EXMP. EXPANDED METAL PLATE
E.B. EXPANSION BOLT
E.J. EXPANSION JOINT
EXP EXPOSED
EXT. EXTERIOR
EXS. EXTRA STRONG
EXTR. EXTRUDE (R)
EXP. EXPANSION
EMBED. EMBEDMENT
F.O.W. FACE OF WALL
FB. FACE BRICK
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.M. FACE OF MASONRY
F.O.S. FACE OF STUD
F/F FACE TO FACE OR FINISHED FLOOR
F.F. FACTORY FINISH
FAS. FASTEN (ER)
FN. FENCE
FBD. FIBERBOARD
FIN. FINISH
F.S. FAR SIDE
FRC. FIRE RESISTANT COATING
FRT. FIRE RETARDANT
FIXT. FIXTURE
F.P. FIRE PROOF OR FIRE PLACE
FLG. FLASHING OR FLANGE
FHMS. FLATHEAD MACHINE SCREW
FHWS. FLATHEAD WOOD SCREW
FLX. FLEXIBLE
FLR. FLOOR (ING)
FLCO. FLOOR CLEANOUT
F.D. FLOOR DRAIN
FPL. FLOOR PLATE
FFL. FINISHED FLOOR LINE
F.A. FIRE ALARM
FBRK. FIRE BRICK
F.E. FIRE EXTINGUISHER (BRACKET)
F.E.C. FIRE EXTINGUISHER (CABINET)
F.H. FIRE HYDRANT
FHS. FIRE HOSE STATION
FHC. FIRE HOSE CABINET
FLUR. FLUORESCENT
FJT. FLUSH JOINT
FTG. FOOTING
FRG. FORGED
FND. FOUNDATION
FRMG. FRAME (ED) (ING)
FRZR. FREEZE (ER)
FRA. FRESH AIR
FS. FULL SIZE
F.B.O. FURNISHED BY OTHERS
F.B.O. FURR (ED) (ING)
FUT. FUTURE
FT. FEET
F.M. FIRE MAIN
FRP. FIBERGLAS REINFORCED PANEL(S)
GST. GLAZED STRUCTURAL PANEL
G.B. GRAB BAR
GD. GRADE OR GRADING
GRN. GRANITE
GRAT. GRATING
GVL. GRAVEL
G.F. GROUND FACE
GRT. GROUT
GPL. GYPSUM PLASTER LATH
GPT. GYPSUM TILE
H HIGH
H.C. HOLLOW CORE
HORIZ. HORIZONTAL
HDW./ HW HARDWARE SET (FINISH OR BUILDERS
HARDWARE)
HY. HYDRANT
HJT. HEAD JOINT
HDR. HEADER
HTG. HEATING
HVAC. HEATING / VENTILATING /
AIR CONDITIONING
H.M. HOLLOW METAL
HK. HOOK
H.B. HOSE BIB
INT. INTERIOR
ILK. INTERLOCK
INTM. INTERMEDIATE
I.E. INVERT ELEVATION
IPS. IRON PIPE SIZE
JT. JOINT
JAN. JANITOR
JC. JANITOR CLOSET
KCP.
JF. JOINT FILLER
JST. JOIST
KEENE'S CEMENT PLASTER
KITCHEN
KICKPLATE
KITCHEN SINK
KNOCKOUT
KP.
KIT.
KS.
KO.
LBL. LABEL
LAD. LADDER
L.B. LAG BOLTS
LAM. LAMINATE (D)
LDRY. LAUNDRY
LAV. LAVATORY
L.H. LEFT HAND
L LENGTH
LT. LIGHT
LC. LIGHT CONTROL
LW. LIGHTWEIGHT
LWC. LIGHTWEIGHT CONCRETE
LTL. LINTEL
LMS. LIMESTONE
L.P. LOW POINT OR LIGHT POLE
LR. LIVING ROOM
MAS. MASONRY
M.O. MASONRY OPENING
MATL./ MAT MATERIAL
MECH. MECHANIC (AL)
M.C. MEDICINE CABINET
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
MOD. MODULAR
MLD. MOLDING OR MOULDING
MR. MOP RECEPTOR
MT. MOUNT (ED), (ING)
MOV. MOVEABLE
MULL. MULLION
NOM. NOMINAL
NMT. NON-METALLIC
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
N.S. NEAR SIDE
OPS. OPPOSITE
OHMS. OVAL HEAD MACHINE SCREW
OHWS. OVAL HEAD WOOD SCREW
OA. OVERALL
OH. OVERHEAD
PTR. PAPER TOWEL RECEPTOR
PAR. PARALLEL
PK. PARKING
PBD. PARTICLE BOARD
PTN. PARTITION
PV. PAVE (D), (ING)
PVMT. PAVEMENT
PED. PEDESTAL
PERF. PERFORATE (D)
PLAS./ PL PLASTER
PLATEPL
PT. POINT OR POINT TANGENT
POL. POLISH (ED)
PTC. POST TENSION CONCRETE
P.C.F. POUNDS PER CUBIC FOOT
P.L.F. POUNDS PER LINEAR FOOT
PCC. PRECAST CONCRETE
PSC. PRESTRESSED CONCRETE
P.L. PROPERTY LINE
PLATE GLASSPG.
PLUMINGPLBG.
PLYWOODPWD.
R.R. RAIL ROAD
REC. RECESS
RFL. REFLECT (ED), (IVE), (OR)
REFR. REFRIGERATOR
REG. REGISTER
REINF. REINFORCE (D), (ING)
REM. REMOVE (ABLE)
RET. RETURN
RA. RETURN AIR
RVS. REVERSE (SIDE)
REF. REFERENCE
REV. REVISION (S), REVISED
R.H. RIGHT HAND
RVT. RIVET
RC. ROOF CONDUCTOR
RD. ROOF DRAIN OR
ROLLING DOOR
RFH. ROOF HATCH
RFG. ROOFING
RM. ROOM
SND. SANITARY NAPKIN DISPENSER
SNR. SANITARY NAPKIN RECEPTACLE
SCH. SCHEDULE (D)
SCN. SCREEN
SNT. SEALANT
STG. SEATING
SEC. SECTION
SS. SERVICE SINK
SHTH. SHEATHING
SHT. SHEET
SG. SHEET GLASS
SH. SHELF OR SHELVING
S & P SHELF AND POLE
SHO. SHORE (D), (ING)
SHWR. SHOWER
SIM. SIMILAR
SKL. SKYLIGHT
SL. SLEEVE
SD. SOAP DISPENSER
SP. SOUNDPROOF
SPC. SPACER
SPK. SPEAKER
SPL. SPECIAL
SPEC. SPECIFICATION (S)
SQ. SQUARE
SQ. SQUARE
STAG. STAGGERED
STD. STANDARD
STA. STATION
STO. STORAGE
SD. STORM DRAIN
STRU. STRUCTURAL
SCT. STRUCTURAL CLAY TILE
SUS. SUSPEND (ED)
SURF. SURFACE
SYM. SYMMETRY (ICAL)
SYN. SYNTHETIC
SYS. SYSTEM
TEMP. TEMPORARY
TKBD. TACK BOARD
TKS. TACK STRIP
TEL. TELEPHONE
TV. TELEVISION
TEMPGL. TEMPERED GLASS
TC. TERRA COTTA
TZ. TERRAZZO
THK. THICK (NESS)
THD. THREAD (ED)
T.O.C. TOP OF CONCRETE
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
T.O.P. TOP OF PIER OR PIPE
TOL. TOLERANCE
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/S TOP OF SLAB
T/STL. TOP OF STEEL
TB. TOWEL BAR
TR. TRANSOM
T.O.F. TOP OF FOOTING
BRKT. BRACKET
GA. GAGE
H.R. HANDRAIL
INFO. INFORMATION
INCL. INCLUDE
J.B. JOIST BEARING
L.G. LONG
MFG. MANUFACTURER
MACH. MACHINE
O/O OUT TO OUT
OPG. OPENING
PC
PEN. PENETRATION
PNL. PANEL
PREV. PREVIOUSLY
L.H. LOUVER HEADER
L.J. LOUVER JAMB
L.S. LOUVER SILL
LB.
LBS.
POUND
POUNDS
REQ'D. REQUIRED
W/O WITHOUT
U/S UNDERSIDE
WC. WATER CLOSET
VB. VAPOR BARRIER
WD. WOOD
QT. QUARRY TILE
QTY. QUANTITY
HT. HEIGHT
H.P. HIGH POINT
H.S.B. HIGH STRENGTH BOLT
WH. WATER HEATER
WP. WATER PROOF (ING)
WIN. WINDOW
W.W.F./ W.W.R/
W.W.M.
WELDED WIRE MESH
WM. WATER MAIN
WSF WELDED SEAM SHEET FLOORING
V.I.F. VERIFY IN FIELD
VIN. VINYL SHEET
T TREAD
YRD. YARD (S)
XS. EXTRA STRONG
ARCHITECTURAL DRAWING ABBREVIATIONS
AF ACCESS FLOORING
ADO AUTOMATIC DOOR OPERATOR
AT (SP) ACOUSTICAL CEILING (W/ SPRAYED PLASTIC FINISH)
AT (TG) ACOUSTICAL CEILING (W/ TEGULAR EDGE)
AWF ACOUSTICAL WALL FABRIC (TACKABLE)
AWP ACOUSTICAL WALL PANEL
BP BP BRICK PAVERS (UNIT PAVERS)
BR BR BRICK (UNIT MASONRY)
CP CARPET (WITHOUT CUSHION BROADLOOM)
EXISTING FINISH TO REMAINEFTR
EPY EPOXY (COATINGS)
ERF EPOXY RESINOUS FLOORING
GL GLASS (GLAZING)
IHM. INSULATED HOLLOW METAL
FF. FROST FREE
F/G FINISHED GRADE
LM LATEX MASTIC FLOORING
MTL. METAL
MC MULTI-COLOR COATING
NF NATURAL FINISH
PC. PIECE
PCP PORTLAND CEMENT PLASTER
PFW POLYPROPYLENE FABRIC WALLCOVERING
PUT POLYURETHANE
RAF RESILIENT ATHLETIC FLOORING
RB. RESILIENT BASE (RUBBER, VINYL)
RF RAISED RUBBER FLOORING
RSF RESILIENT SHEET FLOORING
SC
SF SPECIAL FACED
ST STONE (CAST)
TT TERRAZZO TILE (PLASTIC MATRIX)
VP VENEER PLASTER
WB WALL BORDER
WP
WS. WATER SERVICE
WR. WEATHER RESISTANT
CONSTRUCTION JOINT
CMU. CONCRETE MASONRY UNIT
ELECTRO-MECHANICAL CLOSER-HOLDEREMCH
MHO MAGNETIC HOLD-OPEN (WALL OR FLOOR MTD)
WEST,WIDTH OR WALLCOVERING
(VINYL COATED FABRIC)
RESILIENT TILE FLOORING
(VINYL COMPOSITION TILE)
WALLCOVERING PROTECTIVE
(RIGID PVC SHEET)
WELDED WIRE FABRIC/
WELDED WIRE REINFORCEMENT
HIGH BUILD GLAZED COATING
(SPECIAL COATING)
PRECAST (ARCHITECTURAL
PRECAST CONCRETE PANELS)
F.T. FULLY TEMPERED
SOUND ATTENUATION BATTSAB.
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED/
OWNER INSTALLED
OFCI OWNER FURNISHED/
CONTRACTOR INSTALLED
DAMPERDPR.
DAMP PROOFINGDP.
DEAD LOADD.L.
DEMOLITION OR DEMOLISHDEMO
CL
CLSC2
A # xx xx xx xx
A
MATCH LINE
REFERENCE TAG
(GENERAL\TYPICAL
USE)
SECTION
REFERENCE
ELEVATION
REFERENCE
(INTERIOR and\or
EXTERIOR)
ELEVATION
REFERENCE
(INTERIOR ONLY)
ENLARGED
REFERENCE
REVISION CLOUD &
DELTA
ID. & SHEET LOCATION
REFER TO XXX
ID. NUMBER
REFER TO SHEET
REFER TO XXX
REFER TO SHEET
ID. NUMBER
REFER TO SHEET
ELEVATION ID.
STRUCTURAL
GRID
ALIGN
CONSTRUCTION
ELEVATION, WORK
POINT
KEY NOTE
ROOM
IDENTIFICATION
WINDOW
IDENTIFICATION
DOOR
IDENTIFICATION
FINISH
IDENTIFICATION
CEILING FINISH/
HEIGHT
000'
T \ SLAB
ROOM CODE
WINDOW ID. NO.
DOOR ID. NO.
MATERIAL
COLOR
INDEX TO DRAWING SYMBOLS
XXX #'-##"
NEW COLUMN LINE
EXISTING COLUMN LINE
PARTITION
IDENTIFICATION
OCCUPANT NAME
ROOM NAME
150 SF
150 SF (PFD)
ROOM NO.
USER REQUESTED AREA (NSF)
ROOM AREA (NSF)
ROOM NAME
CL
XX# XX#
##X EQUIPMENT
IDENTIFICATION
2'- 53 4"
S-1 group 3200sf / 300 = 11 occupants
B Business group 2565 sf / 100 = 26 occupants
S-1 Storage group 14,465 sf / 300 = 48 occupants106' exit acce ss dist.
106' exit access dist.
2' -9
1 2"
' E
.A .D
Exit* Exit* Exit* Exit* *Qualifies as an Exit since the overhead door is manually operable on the egress side.
51'
Exit
Exit Exit
Exit
MBC Table 1017.2: S-1 occupancy Exit Access Travel Distance, without sprinkler system = 200 ft.
AB
BR
EV
IA
TI
O
N S, L
IF
E
SA
FE
TY
P
LA
N A
N D
D R
AW
IN
G L
EG
EN
D
CS
-1
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2024
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
BBG
G D
S, G
G G
G
.0 6.
1/
0.
R
LO
.1 5.
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2024
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
BBG
G D
S, G
G G
G
.0 6.
1/
0.
R
LO
.1 5.
SCALE:
N
LIFE SAFETY PLAN
1/32"=1'-0"
1. WHEN MOUNTING MULTIPLE DEVICES FROM DIFFERENT
TRADES IN THE SAME LOCATION (SUCH AS LIGHTING
SWITCHES, LOW VOLTAGE, THERMOSTATS, ETC), THEIR
ARRANGEMENT MUST BE IN ACCORDANCE WITH THE
FOLLOWING:
1.1. LOCATE DEVICES AS SHOWN ON THE
ARCHITECTURAL PLANS, ELEVATIONS OR SECTIONS.
1.2. WHEN SHOWN ON MECHANICAL OR ELECTRICAL
DRAWINGS, BUT NOT ON ARCHITECTURAL
DRAWINGS, DEVICES MUST BE UNIFORMLY AND
SYMMETRICALLY MOUNTED. VERTICALLY ALIGN
DEVICES MOUNTED AT HEIGHTS INDICATED, UNLESS
SEPARATED HORIZONTALLY BY A MINIMUM OF 24".
1.3. DEVICES INSTALLED IN MASONRY OR SURFACES TO
RECEIVE WOOD PANELS, WALL COVERING OR
SIMILAR MATERIALS MUST BE FLUSH WITH THE
FINAL SURFACE MATERIAL.
1.4. IF THE CONTRACTOR HAS ANY DOUBTS REGARDING
THE LOCATION OF DEVICES, THE CONTRACTOR
MUST CONSULT WITH THE ARCHITECT PRIOR TO
ROUGHING-IN.
1.5. AT MULTIPLE SWITCHES, GANG W/ SINGLE COVER
PLATE.
2. DEVIATIONS FROM THE ABOVE INSTRUCTIONS WITHOUT
PRIOR APPROVAL BY THE ARCHITECT MUST BE
CORRECTED BY THE INSTALLING CONTRACTOR. ANY
COST, INCLUDING CUTTING & PATCHING, ENTAILED IN
THE REMOVAL, RELOCATION, AND REINSTALLATION OF
ANY DEVICES WILL BE THE RESPONSIBILITY OF THAT
CONTRACTOR.
GENERAL NOTES FOR
LOCATION OF DEVICES
SIGNAGE
SIGNAGE
9"
SIGNAGE
18"
DRINKING FOUNTAINS/ E.W.C.
E.W.C. OR
DRINKING
FOUNTAIN
(REFER TO
PLUMB.
DWGS.)
15"
TO
S
PO
U
T O
U
TL
ET
E.W.C. OR
DRINKING
FOUNTAIN
HIGH/ LOW
" M
IN
T
O
3" M
AX
" M
AX
" M
IN
9" M
IN
8" MIN.
11" MIN.
4" M
IN
HIGH/LOW UNIT
MAY OCCUR,
REFER TO FLOOR
PLAN
MIN.
TO
S
PO
U
T O
U
TL
ET
5"
MAX.
THE SPOUT MUST PROVIDE
A FLOW OF WATER 4" HIGH
MINIMUM
FORWARD & PARALLEL
APPROACH
3 1/2"
MAX.
E.W.C. OR
DRINKING
FOUNTAIN
" M
IN
CLEAR
SPACE
.6
BOTTLE FILLER
MAY OCCUR,
REFER TO
PLUMBING DWGS.
COUNTERTOP MOUNTED LAV./
HAND SINK
OPEN
MIRROR - REFER TO
INTERIOR
ELEVATIONS
REMOVABLE
MODESTY PANEL W/
CONCEALED CLIPS
BOTTOM EDGE OF
REFLECTING
SURFACE 40" MAX
A.F.F.
TO
C
O U
N
TE
R O
R R
IM
W
H
IC
H
EV
ER
IS
G R
EA
TE
R
5"
15"
TO
C
O U
N
TE
R O
R R
IM
W
H
IC
H
EV
ER
IS
G R
EA
TE
R
5"
30" MIN., U.N.O.
SOAP
DISPENSER
END PANEL
22"
NOTE: REFER TO INTERIOR
ELEVATIONS FOR SPECIFIC
FINISH TYPES AND LOCATIONS
MOUNTING HEIGHTS
SCALE: 1/2"=1'-0"
LIGHT FIXTURE MAY
OCCUR, REFER TO
ELEC.
METAL BRACKET(S)
MAY OCCUR (SPANS
GREATER THAN 36")
SHOWER ENCLOSURE
6' -4
6' -4
3' -6
6' -6
6' -6
OPP. SIDE SIM.
SHOWER
SURROUND,
SEE INTERIOR
ELEVATIONS
PAN, SEE
INTERIOR
ELEVATIONS
CONTROLS
LOCATION
SHOWER ROD W/
CURTAIN (CURTAIN TO
BE LOC. AT SHOWER
SIDE OF THRESHOLD)
FIXED SHOWER
HEAD
CASEWORK MAY
OCCUR, REFER TO
INT. ELEVS.
ACCESSORY MOUNTING HEIGHTS
ELEC.
DEVICES 8"
ABOVE ALL
COUNTERTOPSTV
R
EC
EP
TA
C
LE
S
TE
LE
PH
O
N E/
D
AT
A O
U
TL
ET
TV
O
U
TL
ET
TE
LE
PH
O
N E/
D
AT
A O
U
TL
ET
SW
IT
C H
ES
TV
FI
R
E
AL
AR
M
D
EV
IC
ES
T.V.
MOUNTING -
REFER TO INTERIOR
ELEVATIONS
FOR EXACT
LOCATIONS
8" C
O U
N
TE
R H
EI
G
H T
" A
.F .F
. O R
" B
EL
O
W F
IN
IS
H C
EI
LI
N G
W H
IC
H
EV
ER
IS
L
ES
S
" U
.N .O
5"
TYPICAL LOCATIONS
TELEPHONE
OUTLET AND
DUPLEX
RECEPTACLE
IN A QUAD BOX
WITH DIVIDER
WHERE TELEPHONE, TV
OR DATA OUTLETS ARE
INDICATED AT THE SAME
LOCATION AS A DUPLEX
RECEPTACLE THEY ARE
TO BE IN A QUAD BOX
WITH DIVIDER
DESK
NOTE:
ALL RECEPTACLES SHALL
BE 18" A.F.F UNLESS
NOTED OTHERWISE
(B
EL
O W
D
ES
K)
(T
YP
IC
AL
WHERE SWITCH IS
INDICATED AT THE
SAME LOCATION AS
DUPLEX RECEPTACLE
THEY ARE TO BE IN A
QUAD BOX WITH
DIVIDER
SWITCHES
"R
EC
EP
TA
C
LE
W / P
H O
N E, T V
O R
D
AT
A
C
LO
TH
ES
H O
O
KS
R
O
BE
H O
O
KS
SO
AP
D
IS
PE
N
SE
R
TO
O
PE
R
AB
LE
P
AR
T
D R
AP
ER
Y/
SH
AD
E/
B
LI
N D
S C
O N
TR
O
LS
IN
TE
R C
O M
S
TA
TI
O
N
IN
D
IM
M
ER
S W
IT
C
H
PR
O
XI
M
IT
Y
SW
IT
C H
PS
TH
ER
M O
ST
AT
/H
VA
C C
O N
TR
O
LS
T
FI
R
E
AL
AR
M
P U
LL
ST
AT
IO
N
F
TO
O
PE
R
AB
LE
P
AR
T
TO
W
EL
D
IS
PE
N
SE
R
FI
R
E
EX
TI
N
G U
IS
H
ER
C
AB
IN
ET
S
(4 0#
O R
L
ES
S)
R
EC
EP
TA
C
LE
S
SCALE: 1/2"=1'-0"
WATER CLOSETS COUNTERTOP MOUNTED LAV./
HAND SINK
OPEN
MIRROR - REFER
TO
INTERIOR
ELEVATIONS
REMOVABLE
MODESTY PANEL W/
CONCEALED CLIPS
**FLUSH CONTROLS MUST BE
LOCATED ON THE OPEN SIDE OF
THE WATER CLOSET.
BOTTOM EDGE OF
REFLECTING
SURFACE 40" MAX
A.F.F.
8"
11"
17" 5"
9"
TO
C
O U
N
TE
R O
R R
IM
W
H
IC
H
EV
ER
IS
G R
EA
TE
R
5"
15"
TO
C
O U
N
TE
R O
R R
IM
W
H
IC
H
EV
ER
IS
G R
EA
TE
R
5"
30" MIN., U.N.O. 42" 18"
36" 6"
24" 12"
" 40
12" 42"
54"
40"
REQUIRED
CLEAR AREA
SOAP
DISPENSER
TOILET PAPER
DISPENSER
9"
END PANEL
22"
NOTE: REFER TO INTERIOR
ELEVATIONS FOR SPECIFIC
FINISH TYPES AND LOCATIONS
FLUSH VALVE
MAY OCCUR,
REFER TO
PLUMBING
DRAWINGS
STANDARD BARRIER FREE MOUNTING HEIGHTS
SCALE: 1/2"=1'-0"
URINAL
WALL MOUNTED
18" 18"
36" MIN.
LIGHT FIXTURE MAY
OCCUR, REFER TO
ELEC.
METAL BRACKET(S)
MAY OCCUR (SPANS
GREATER THAN 36") 18
1.
5"
M
IN
SEAT
COVER
DISP.
SANITARY
NAPKIN
DISPOSAL
GRAB BARS
WOOD
BLOCKING, TYP.
@ STUD WALLS,
GROUTED
ANCHORS TYP.
@ MASONRY/
CONC.
ANCHOR TO
RESIST FORCES
INDICATED
MIN. 250 LB.
HORIZONTAL
FORCE
M
IN
. 2
L B.
VE
R
TI
C
AL
FO
R C
E
GRAB BAR
2"
WALL CONSTRUCTION,
REFER TO WALL
TYPES
M O
U N
TI
N
G H
EI
G
H
TS
, S
IG
N
AG
E
AN
D C
O N
TR
O
LS
CS
-2
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2024
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
BBG
G D
S, G
G G
G
.0 6.
1/
0.
R
LO
.1 5.
2'-91 2" 3'-5" 2'-91
2"
9'-0" PIT
8" 2'
-6
'-0
1 2" P
IT
5'-6"
5' -0
5'-6"9'-0"
3'-5"
3' -1
2"
2'-91 2"
CL
CL
EQ. EQ.
OF BAY
OF BAY
CL
2'-4"
1' -7
"10"
1' -1
0"
2'-9"
CL
2'-4"
20'-0"
CL
CL
EXISTING NOTES
1. CONTRACTOR MUST VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING
CONDITIONS. VERIFY MEASUREMENTS WITH CORRESPONDING CONSTRUCTION OR EXISTING
CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT
IMMEDIATELY OF SIGNIFICANT DISCREPANCIES.
2. VERIFY ALL CONDITIONS COVERING OR AFFECTING THE STRUCTURAL WORK; OBTAIN AND
VERIFY ALL DIMENSIONS AND ELEVATIONS TO ENSURE THE PROPER STRENGTH, FIT AND
LOCATION OF THE STRUCTURAL WORK; REPORT TO THE ARCHITECT ANY AND ALL
CONDITIONS WHICH MAY INTERFERE WITH OR OTHERWISE AFFECT OR PREVENT THE
PROPER EXECUTION AND COMPLETION OF THE NEW WORK. ALL DISCREPANCIES SHALL BE
FULLY RESOLVED PRIOR TO COMMENCING WORK.
3. EXISTING CONSTRUCTION NOT UNDERGOING ALTERATION IS TO REMAIN UNDISTURBED,
WHERE SUCH CONSTRUCTION IS DISTURBED AS A RESULT OF THE OPERATIONS OF THIS
CONTRACT, IT MUST BE REPAIRED OR REPLACED BY THE CONTRACTOR AS REQUIRED AND
TO THE SATISFACTION OF THE ARCHITECT.
4. WHERE THE EXISTING CONSTRUCTION IS TO BE ALTERED, OR OTHERWISE DISTURBED,
PROVIDE TEMPORARY AND/OR PERMANENT BRACING AND SHORING AS MAY BE REQUIRED
BEFORE AND DURING OPERATIONS AND UNTIL THE WORK IS SAFELY COMPLETED AND NO
LONGER NEEDS SAME.
5. EACH CONTRACTOR SHALL PROVIDE ALL THE NECESSARY SUPPORT, BRACING, SHORING,
ETC. (TEMPORARY AND/OR PERMANENT) OF BOTH NEW AND EXISTING CONSTRUCTION AS
REQUIRED FOR THE SAFE INSTALLATION OF THE NEW CONSTRUCTION AND EQUIPMENT.
6. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS
FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURE AND SEQUENCE, AND TO ENSURE THE SAFETY OF THE BUILDING AND
ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF TEMPORARY
BRACING, GUYS OR TIE-DOWNS IF NECESSARY.
7. THE CONTRACTOR IS RESPONSIBLE FOR MEANS, METHODS, SEQUENCES, AND PROCEDURES
OF CONSTRUCTION.
8. PROVIDE FIRE WATCH DURING FIELD CUTTING AND WELDING OPERATIONS, MEETING THE
OWNER'S REQUIREMENTS.
9. ALL EXISTING STRUCTURAL MEMBERS TO REMAIN, U.N.O.
CONTINUED USE OF FACILITIES:
1. EACH CONTRACTOR SHALL AT ALL TIMES MAINTAIN A CLEAN AND SAFE PASSAGEWAY FOR
THE OWNER' S OPERATION AND PERSONNEL IN EXISTING AREAS AND MAINTAIN CLEARANCES
ADJACENT TO AND IN CONNECTION WITH THE WORK PERFORMED.
2. EACH CONTRACTOR SHALL EFFECTIVELY CONFINE DUST, DIRT AND NOISE TO THE ACTUAL
CONSTRUCTION AREA AS APPROVED BY THE GENERAL CONTRACTOR IN ACCORDANCE WITH
STATE OF MICHIGAN REGULATIONS.
3. WORK SHALL, IF REQUIRED, BE CONSTRUCTED IN PHASES TO ACCOMMODATE THE OWNER'S
USE OF THE PREMISES DURING THE CONSTRUCTION PERIOD AND FOR INSTALLATION OF HIS
EQUIPMENT. COORDINATE THE CONSTRUCTION SCHEDULE WITH THE GENERAL
CONTRACTOR AND OWNER'S REPRESENTATIVE.
4. DURING THE CONTRACTOR'S PERFORMANCE OF THE WORK OF THIS CONTRACT, THE
OWNER'S WILL CONTINUE TO OCCUPY THE EXISTING BUILDING. INTERRUPTION OF BUILDING
ACCESS AND FACILITIES BY THE CONTRACTOR WILL NOT BE PERMITTED; TO WHATEVER
EXTENT SUCH INTERRUPTIONS MIGHT INTERFERE WITH OWNER'S OCCUPANCY. LIMIT
CONSTRUCTION OPERATIONS TO THOSE METHODS AND PROCEDURES WHICH WILL NOT
ADVERSELY AND UNDULY EFFECT THE WORKING ENVIRONMENT OF OWNER'S OCCUPIED
SPACES, INCLUDING NOISE, DUST, ODORS, AIR POLLUTION, AMBIENT DISCOMFORT, POOR
LIGHTING, HAZARDS AND OTHER UNDESIRABLE EFFECTS AND CONDITIONS. COORDINATE AND
SCHEDULE ALL WORK IN EXISTING BUILDING WITH OWNER AND GENERAL CONTRACTOR.
1. ALL EXISTING CONSTRUCTION TO REMAIN U.N.O.
2. REMOVE ALL MATERIALS AND DEBRIS CREATED DURING THE DEMOLITION AND/OR CONSTRUCTION PROCESS AND DISPOSE OFF SITE IN A SAFE AND LEGAL MANNER.
3. PERFORM ALL DEMOLITION WORK REQUIRED ON THE EXISTING BUILDING AS CALLED FOR ON THE DRAWINGS AND/OR AS REQUIRED TO ACCOMMODATE THE WORK.
4. CAP, PATCH AND REPAIR ALL HOLES AND SURFACES IN WALLS, FLOORS AND CEILINGS WHERE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND/OR ELECTRICAL ITEMS ARE REMOVED AS A
RESULT OF THE DEMOLITION OPERATIONS.
5. ALL EXISTING CONCRETE SLAB ON GRADE TO REMAIN. PATCH AND REPAIRED, AND/OR FILL EXISTING CONST. AS REQ. TO RECEIVE NEW FINISHES.
6. CARRY OUT ALL DEMOLITION WORK IN CLOSE COORDINATION AND COOPERATION WITH STRUCTURAL TRADES FOR PROPER SEQUENCING OF THE WORK TO ASSURE THE COMPLETE SAFETY AND STRUCTURAL INTEGRITY OF THE BUILDING AND ITS ELEMENTS AT ALL TIMES. PROVIDE TEMPORARY COLUMNS, JACKS, BEAMS, ETC., WHERE REQUIRED FOR SUPPORT OF EXISTING ELEMENTS OF CONSTRUCTION TO REMAIN IN SAFE, COMPETENT MANNER, IN CONFORMANCE WITH ALL LAWS, CODES ORDINANCES, RULES AND REGULATIONS BEARING ON THE WORK.
7. DEMOLITION OF ALL PORTIONS OF THE STRUCTURE TO BE REMOVED SHALL BE DONE WITH UTMOST CARE, USING TOOLS AND METHODS SUBJECT TO OWNER'S APPROVAL. ALL POSSIBLE CARE SHALL BE TAKEN TO AVOID DAMAGING, SHOCK OR VIBRATION TO PORTIONS OF EXISTING STRUCTURE TO REMAIN.
8. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, LOCATION AND ELEVATION OF EXISTING SEWERS, DRAINS, ETC. IN DEMOLITION AREAS BEFORE PROCEEDING WITH THE WORK, ALL
DISCREPANCIES SHALL BE DOCUMENTED AND REPORTED TO THE ARCHITECT.
9. SAW CUT & REMOVE EXISTING CONCRETE SLAB FOR PLACEMENT OF PLUMBING WORK, FOUNDATIONS, STRUCTURAL STEEL, NECESSARY CAPPING OF EXISTING LINES AND FOUNDATION WORK, ETC. COORDINATE WITH STRUCTURAL ENGINEER AND ARCHITECT.
10. REMOVE AND RELOCATE MECHANICAL AND ELECTRICAL ITEMS, INCLUDING PIPING, FIXTURES, EQUIPMENT, DUCTWORK, WIRING DEVICES, PANELS AND ACCESSORIES AS REQUIRED. REFER TO
MECHANICAL AND ELECTRICAL DRAWINGS FOR MECHANICAL AND ELECTRICAL DEMOLITION.
11. REMOVE, ABANDON AND/OR CAP EXISTING PLUMBING AS REQUIRED TO FACILITATE THE WORK, V.I.F..
12. ALL EXISTING MATERIALS INDICATED TO REMAIN SHALL BE REPAIRED TO MATCH EXISTING. MATERIALS BEYOND REPAIR SHALL BE REPLACED TO MATCH EXISTING.
13. REMOVE AND REPLACE ALL EXISTING CONSTRUCTION AS INDICATED ON THE DEMOLITION PLANS OR OTHERWISE INDICATED IN ORDER TO FACILITATE THE NEW WORK.
14. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIFIC TRADE RELATED DEMOLITION WORK.
15. REFER TO DEMOLITION, IN THE SPECIFICATIONS FOR FURTHER INFORMATION PRIOR TO THE START OF DEMOLITION.
DEMOLITION NOTES
1. ALL DIMENSIONS ARE TO FACE OF
STUDS/ SHEATHING/
MASONRY/CONCRETE, CENTERLINE OF
OPENINGS FOR DOORS AND WINDOWS
IN STUD CONSTRUCTION (FACE OF
OPENING WHEN LOCATED IN
MASONRY/CONCRETE). DO NOT SCALE
DRAWINGS.
ALL EXISTING CONSTRUCTION
DIMENSIONS ARE TO FACE OF
EXISTING GYP. BD. U.N.O., V.I.F.
2. VERIFY SIZE AND LOCATION OF
MECHANICAL AND ELECTRICAL
EQUIPMENT, PADS, PENETRATIONS
AND SUPPORTS WITH MECHANICAL
AND ELECTRICAL DRAWINGS.
3. SLOPE FLOORS TO DRAINS AT 1/8" PER
FOOT MINIMUM WHILE KEEPING FLOOR
LEVEL AT WALL BASE CONDITION. (DO
NOT EXCEED 2% SLOPE IN ANY
DIRECTION). REFER TO STRUCTURAL
FOR ADDITIONAL INFORMATION.
4. COORDINATE ALL UTILITY LOCATIONS
WITH CIVIL, PLUMBING AND
ELECTRICAL DRAWINGS.
5. PATCH AND REPAIR ALL EXISTING
CONSTRUCTION DAMAGED AS A
RESULT OF NEW WORK/DEMOLITION
TO MATCH EXISTING CONDITIONS,
U.N.O.
6. REFER TO SHEET CS-002 FOR ANY
MOUNTING HEIGHTS.
7. REFER TO SPECIFICATIONS MANUAL
FOR ADDITIONAL INFORMATION.
GENERAL FLOOR
PLAN NOTES
1. THIS PLAN IS INTENDED TO SHOW
GENERAL COORDINATION OF
OVERHEAD WORK. REFER TO
STRUCTURAL, PLUMBING &
ELECTRICAL DRAWINGS FOR FURTHER
INFORMATION.
2. FANS TO BE LOCATED AT SAME
ELEVATION AS EXISTING FANS.
3. REFER TO SPECIFICATIONS MANUAL
FOR ADDITIONAL INFORMATION.
GEN. CEILING NOTES
SCALE:
N
REFECTED CEILING PLAN
1/8"=1'-0"
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2024
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
BBG
G D
S, G
G G
G
.0 6.
1/
0.
R
LO
.1 5.
SCALE:
N
HOIST PIT PLAN
1/8"=1'-0"
NEW CEILING FANREMOVE / DISCARD
EXSITING FAN
EXISTING MONORAIL
BEAM HALF AND HOIST
MOTOR TO REMAIN
CUT AND REMOVE
EXIST. MONORAIL
EXIST. BOLLARDS
EXIST. DRAIN PIT
JACKING
BEAM PIT
EDGE OF NEW
CONC. SLAB
2" CONC. CONSOLE PAD
SCALE:
N
CONSOLE PAD PLAN
1/4"=1'-0"
EXISTING FAN TO
BE REPLACED
WITH NEW FAN
SEE STRUCT. FOR
END STOP LOCATION
EXIST. OH DOORS
2" CONC. PAD - SEE
STRUCTURAL DWGS.
AREA OF
CONC. CUT
EXIST. TO
REMAIN
SCALE:
N
DEMOLITION PLAN
1/8"=1'-0"
EXISTING CONC. SLAB
TO BE DEMOLISHED
(800 SQ. FT.)
EXISTING BOLLARDS
TO REMAIN
EDGE OF NEW CONC. SLAB
D
EM
O
LI
TI
O
N P
LA
N
, P
LA
N , E
N
LA
R G
ED
P
LA
N
, R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
A-
EXISTING CONC. SLAB TO
BE CUT FOR DRAIN LINE
FLOOR DRAINS
EX. BOLL.
CONC. SLAB INFILL
EXIST. DRAIN PIT
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2024
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
BBG
G D
S, G
G G
G
.0 6.
1/
0.
R
LO
.1 5.
LI
FT
IN
ST
AL
L
PL
AN
S, C
ER
TI
FI
C
AT
IO
N
A-
GENERAL STRUCTURAL NOTES
1. ALL CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF MIOSHA, THE MICHIGAN BUILDING CODE, ADOPTED EDITION, AND THE LOCAL GOVERNING CODE, LATEST EDITIONS, AND ALL REQUIREMENTS SPECIFIED IN THE CODES SHALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. THIS SHALL NOT BE CONSTRUED TO MEAN THAT ANY REQUIREMENTS SET FORTH ON THE DRAWING MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE
REQUIREMENTS OR BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE.
2. PRIOR TO SUBMITTING PROPOSAL, VERIFY ALL CONDITIONS GOVERNING OR AFFECTING THE STRUCTURAL WORK. OBTAIN AND VERIFY ALL DIMENSIONS TO ENSURE THE PROPER FIT AND LOCATION OF THE STRUCTURAL WORK, TAKE ADDITIONAL DIMENSIONS AS REQUIRED, REPORT TO THE ENGINEER ANY AND ALL CONDITIONS WHICH MAY INTERFERE WITH OR OTHERWISE AFFECT OR PREVENT THE PROPER EXECUTION AND COMPLETION OF THE WORK, FAMILIARIZE YOURSELF WITH THE ACTUAL CONDITIONS OF
THE STRUCTURAL WORK, ACCESS TO THE SITE, AVAILABLE STORAGE SPACE, FACILITIES AND
OBSTRUCTIONS THAT MAY BE ENCOUNTERED DURING THE PROGRESS OF WORK.
3. CONTRACTOR TO FURNISH ALL NECESSARY LABOR, MATERIAL, EQUIPMENT AND FACILITIES TO FURNISH, FABRICATE AND PERFORM THE REQUIRED STRUCTURAL WORK.
4. ALL WORK SHOWN ON THESE DRAWINGS MAY BE CHECKED BY AN INDEPENDENT TESTING AGENCY RETAINED BY OWNER TO ENSURE COMPLIANCE WITH THE REQUIREMENTS SHOWN ON THE DRAWINGS. THE
CONTRACTOR SHALL PROVIDE ACCESS AS REQUIRED FOR TESTING PURPOSES.
5. CONTRACTOR SHALL MAKE ALL NECESSARY FIELD VISITS FOR INSPECTION, MEASUREMENTS AND
VERIFICATION OF EXISTING CONDITION OF BUILDING.
6. THE GENERAL STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS AND SPECIFICATIONS.
SHOULD CONFLICTS EXIST BETWEEN THE DRAWINGS, SPECIFICATION, AND/OR THE GENERAL STRUCTURAL
NOTES, THE STRICTEST PROVISION AS DETERMINED BY THE ENGINEER SHALL GOVERN.
7. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE, AND TO ENSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF TEMPORARY BRACING, GUYS AND/OR TIE-DOWNS AS NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE
PROJECT.
8. WORK THE STRUCTURAL DRAWINGS IN CONJUNCTION WITH THE ARCHITECTURAL, MECHANICAL, SITE AND
ELECTRICAL DRAWINGS.
9. USE OF ENGINEERING DRAWINGS AS ERECTION DRAWINGS BY THE CONTRACTOR IS STRICTLY PROHIBITED.
SITE PREPARATION
1. AT THE START OF EARTHWORK OPERATIONS, ALL SURFACE VEGETATION SHALL BE CLEARED AND THE EXISTING TOPSOIL AND ANY OTHER ORGANIC SOILS SHALL BE REMOVED IN THEIR ENTIRETY FROM BELOW THE PROPOSED BUILDING AND PAVEMENT AREAS. EXISTING RANDOM CONCRETE AND OTHER DEBRIS SHALL
BE REMOVED FROM WITHIN THE BUILDING AREA.
2. THE SUB-GRADE SHOULD BE THOROUGHLY PROOF-ROLLED WITH A HEAVY RUBBER-TIRED VEHICLE SUCH AS A LOADED SCRAPER OR LOADED DUMP TRUCK. ANY AREAS THAT EXHIBIT EXCESSIVE PUMPING AND YIELDING DURING PROOF-ROLLING SHOULD BE STABILIZED BY AERATION, DRYING AND COMPACTION IF WEATHER CONDITIONS ARE FAVORABLE, OR REMOVAL AND REPLACEMENT WITH ENGINEERED FILL.
3. ALL EXCAVATIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER'S REPRESENTATIVE, WHO SHALL BE CONSULTED WHEN POOR SOIL, WATER, OBSTRUCTIONS, PIPING, EXISTING FOOTINGS, EXCAVATIONS, ETC., ARE ENCOUNTERED.
9. CONTRACTOR SHALL FURNISH ALL REQUIRED DEWATERING EQUIPMENT TO MAINTAIN A DRY EXCAVATION UNTIL
BACKFILL IS COMPLETE.
BACKFILLING
1. MATERIAL FOR BACKFILL OR ENGINEERED FILL REQUIRED TO ACHIEVE DESIGN GRADES SHOULD CONSIST OF NON-ORGANIC SOILS. THE ON-SITE SOILS THAT ARE FREE OF ORGANIC MATTER AND DEBRIS MAY BE USED FOR
ENGINEERED FILL WITH ENGINEER'S APPROVAL.
2. BACKFILL MATERIAL SHALL BE COMPACTED TO 95% OF ITS' MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR METHODS (ASTM D1557), IN LIFTS NOT EXCEEDING 12-INCHES IN LOOSE THICKNESS.
3. FROZEN MATERIAL SHALL NOT BE USED AS FILL, NOR SHALL FILL BE PLACED ON FROZEN SUB-GRADE.
4. DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS UNTIL BASEMENT FLOOR LEVEL AND FIRST FLOOR LEVEL SLABS ARE IN PLACE AND HAVE REACHED 75% OF THEIR SPECIFIED DESIGN STRENGTH. SHORE AND BRACE WALLS AS REQUIRED IF BACKFILLING OPERATIONS ARE TO BE CARRIED OUT PRIOR TO PLACEMENT OF
FLOOR SLABS.
5. PLACE BACKFILL AGAINST BOTH SIDES OF GRADE BEAMS AND FOUNDATIONS AT EQUAL ELEVATIONS OF FILL, EXCEPT AS SHOWN ON THE DRAWINGS.
6. CRUSHED SLAG USED AS BACKFILL SHALL BE AGED, ENVIRONMENTALLY-SAFE PROCESSED BLAST FURNACE
SLAG.
STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATION:
* WIDE FLANGE AND WT SHAPES - A992
* HSS RECT. - A500 GRADE B (fy = 46 KSI)
* HSS ROUND - A500 GRADE B (fy = 42 KSI)
* PIPE - A53 GRADE B (fy = 35 KSI)
* HP SHAPES - A572 GR. 50
* ALL OTHER SHAPES AND PLATES - A36
2. THE FABRICATOR/ERECTOR SHALL SUBMIT TO THE ENGINEER FOR REVIEW, ENGINEERED AND CHECKED DRAWINGS SHOWING SHOP FABRICATION DETAILS, FIELD ASSEMBLY DETAILS AND ERECTION DIAGRAMS FOR
ALL STRUCTURAL STEEL.
3. BEAM CONNECTIONS SHALL BE STANDARD TWO ANGLE WEB CONNECTIONS CAPABLE OF SUPPORTING 50% OF THE ALLOWABLE UNIFORM LOAD FROM THE ALLOWABLE LOADS ON BEAM TABLES IN THE AISC CODE, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS.
4. ALL CONNECTIONS NOT SPECIFICALLY DETAILED, SHALL BE DESIGNED AND DETAILED BY THE FABRICATOR.
DETAILING SHALL BE PERFORMED USING RATIONAL ENGINEERING DESIGN AND STANDARD PRACTICE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE GENERAL DETAILS SHOWN ON THE DRAWINGS ARE APPROXIMATE ONLY AND DO NOT INDICATE THE REQUIRED NUMBER OF BOLTS OR WELD SIZES, UNLESS
SPECIFICALLY NOTED.
5. ALL CONNECTIONS SHALL BE SHOP WELDED IN ACCORDANCE WITH LATEST AWS SPECIFICATION USING E7OXX ELECTRODES AND FIELD BOLTED WITH ASTM A325 OR A490 BOLTS. ALL A325 AND A490 BOLTS ARE TO BE INSTALLED IN ACCORDANCE WITH THE LATEST "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH
STRENGTH BOLTS."
6. EXCEPT AS NOTED ON THE DRAWINGS, STRUCTURAL STEEL BOLTS SHALL BE ASTM A325, 3/4" DIAMETER. ALL VERTICAL BOLTS ARE TO BE INSTALLED "HEAD UP" UNLESS SPECIFICALLY NOTED. IF A BOLT CANNOT BE INSTALLED "HEAD UP", THE THREAD IS TO BE "SPOILED" AFTER THE BOLT HAS BEEN PROPERLY TIGHTENED
AND THEN INSPECTED BY THE TESTING AGENCY.
7. HIGH STRENGTH BOLT INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF AISC AND THE "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS." PROVIDE FULLY PRETENSIONED JOINTS AT CONNECTIONS OF BRACING, WHERE BOLTS ARE IN TENSION, ARE SUBJECT TO LOAD REVERSALS OR FATIGUE, AND AT MOMENT CONNECTIONS. PROVIDE SLIP-CRITICAL JOINTS AT CONNECTIONS SUBJECT TO FATIGUE AND LOAD REVERSALS, OVERSIZED HOLES, SLOTTED HOLES AND WHERE SLIP AT THE FAYING SURFACES WOULD BE DETRIMENTAL TO THE PERFORMANCE OF THE STRUCTURE. ALL OTHER CONNECTIONS
MAY HAVE SNUG-TIGHTENED CONNECTIONS UNLESS OTHERWISE NOTED.
8. ALL SIMPLE SHEAR CONNECTIONS SHALL BE CAPABLE OF END ROTATION PER THE REQUIREMENTS OF THE
AISC 360 SECTION J1.2.
9. ALL ANCHOR RODS SHALL CONFORM TO ASTM F1554 GR. 36.
10. CONTRACTOR SHALL REFERENCE ARCHITECTURAL DRAWINGS FOR MISC. SHAPES AND PLATES WHICH SHALL BE SHOP-WELDED TO THE STRUCTURAL FRAMING SECTIONS TO MINIMIZE FIELD WELDING.
11. ALL FLOOR AND ROOF OPENINGS, UNLESS OTHERWISE NOTED, ARE TO BE FRAMED WITH L5X3X1/4 (LLV).
VERIFY SIZE AND LOCATION OF ALL OPENINGS WITH THE TRADE INVOLVED.
12. PROVIDE L4X4X1/4 SEATS AT COLUMN WEBS, WHERE REQUIRED FOR SUPPORT OF ROOF AND FLOOR DECKS.
13. ALL BEAMS SHALL BE FABRICATED WITH THE NATURAL CAMBER UP. PROVIDE CAMBERS AS INDICATED ON
THE DRAWINGS.
14. ALL STIFFENER PLATES AND BEARING STIFFENERS ARE TO BE PROVIDED IN PAIRS.
15. SHEAR CONNECTORS SHALL BE MANUFACTURED BY NELSON STUD WELDING, DIV. OR ENGINEER APPROVED
SUBSTITUTE, AND WELDED PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
16. ALL STEEL TO RECEIVE ONE SHOP COAT OF PAINT. OMIT PAINT AT HOLES FOR SLIP CRITICAL-TYPE CONNECTIONS, AT STRUCTURAL STEEL TO BE FIREPROOFED, ENCASED OR IN CONTACT WITH CONCRETE, AND ON TOP FLANGE OF BEAMS RECEIVING SHEAR CONNECTORS.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF ALL ERECTION PROCEDURES AND
SEQUENCES WITH RELATION TO TEMPERATURE DIFFERENTIALS, ESPECIALLY WITH RESPECT TO
STRUCTURAL STEEL FRAMING INTO CONCRETE WALLS, BEAMS OR COLUMNS.
18. PROVIDE TEMPORARY BRACING AS REQUIRED TO ENSURE STABILITY OF THE STRUCTURE UNDER FULL DESIGN LOADS UNTIL THE PERMANENT BRACING IS IN PLACE. CONTRACTOR SHALL PROVIDE NECESSARY
SHORING WHERE REQUIRED DURING CONSTRUCTION.
19. SHOP AND FIELD TESTING OF WELDS AND OR BOLTS SHALL BE AS FOLLOWS:
A. ALL WELDS SHALL BE VISUALLY INSPECTED. 5% AT RANDOM SHALL BE MEASURED.
B. FILLET WELDS FOR BEAM AND GIRDER SHEAR CONNECTION PLATES (10% AT RANDOM) SHALL BE
CHECKED BY MAGNETIC PARTICLE IN ACCORDANCE WITH ASTM E709 FOR FINAL PASS ONLY.
C. ULTRASONICALLY TEST 100% OF ALL FULL-PENETRATION WELDS IN ACCORDANCE WITH AWS D1.1 -
SECTION, PART 'F', “ULTRASONIC TESTING (UT) OF GROOVE WELDS”.
D. CHECK BY CALIBRATED TORQUE WRENCH, 25% OF BOLTS IN EACH FULLY PRETENSIONED CONNECTION
JOINT OR SLIP-CRITICAL CONNECTION JOINT, BUT NOT LESS THAN TWO (2) BOLTS PER CONNECTION.
E. ULTRASONICALLY TEST 100 % OF ALL PARTIAL-PENETRATION COLUMN SPLICE WELDS IN ACCORDANCE
WITH AWS D1.1 - SECTION, PART 'F', “ULTRASONIC TESTING (UT) OF GROOVE WELDS”.
F. CHECK 100% OF CONTINUITY PLATE FILLET WELDS BY MAGNETIC PARTICLE ON LAST LAYERS IN
ACCORDANCE WITH ASTM E709.
G. THE OWNER'S TESTING AGENCY SHALL PERFORM ALL SHOP AND FIELD INSPECTION AND TESTING AS
OUTLINED ABOVE.
H. THE STRUCTURAL STEEL FABRICATOR AND ERECTOR SHALL SCHEDULE ALL WORK TO ALLOW THE
ABOVE TESTING REQUIREMENTS TO BE COMPLETED.
20. STRUCTURAL STEEL SHALL NOT BE ALTERED IN THE FIELD FROM THAT SHOWN ON THE DESIGN DRAWINGS.
MISMATCHED HOLES SHALL BE REAMED TO LARGER DIAMETER AND PROPERLY SIZED BOLTS AND WASHERS USED FOR FINAL HOLE SIZE. CUTTING, BURNING OR WELDING NOT SHOWN ON DESIGN DRAWINGS SHALL NOT
BE PERFORMED WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ENGINEER.
21. ALL STRUCTURAL STEEL SHALL BE DETAILED, SHOP PRIME PAINTED OR HOT-DIPPED GALVANIZED, PIECE MARKED, FURNISHED, FABRICATED AND ERECTED ACCORDING TO THE AISC "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS", LATEST EDITION AND TO THE AISC "CODE OF STANDARD PRACTICE".
HOT DIP GALVANIZED FINISH FOR ALL STEEL MEMBERS EXPOSED TO THE WEATHER.
22. NON-SHRINK GROUT SHALL CONFORM TO "CORPS OF ENGINEERS SPECIFICATION FOR NON-SHRINK GROUT", CRD-C 621-LATEST EDITION. GROUT SHALL BE PREMIXED, NON-SHRINK, NON-CATALYZED NATURAL AGGREGATE GROUT FOR: (1) COLUMN LEVELING PLATES, WHICH ARE NOT BOLTED DOWN BEFORE COLUMN ERECTION, (2) ITEMS SET INTO CONCRETE BLOCKOUTS, DEPRESSIONS, OR TOPPINGS, AND (3) OTHER STRUCTURAL LOAD BEARING APPLICATIONS. THE SEVEN-DAY COMPRESSIVE FOR THE SPECIFIED CONSISTENCY SHALL BE AT LEAST, 7,000 PSI PLASTIC, 6,000 PSI FLOWABLE, AND 5,000 PSI FLUID
CONSISTENCY.
CAST-IN-PLACE CONCRETE
1. ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301- LATEST ADOPTED EDITION, "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING", EXCEPT AS MODIFIED BY STRUCTURAL
REQUIREMENTS NOTED ON THE DRAWINGS.
2. ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH (f 'c) OF 4000 psi.
3. ALL EXTERIOR CONCRETE INCLUDING WALLS SHALL BE AIR-ENTRAINED 5% +/- 1%.
4. ALL EXTERIOR CONCRETE EXPOSED TO WEATHER SHALL HAVE A MAXIMUM WATER TO CEMENT RATIO OF (W/C) 0.45.
5. UNLESS NOTED OTHERWISE, MINIMUM CONCRETE COVER SHALL BE:
CONCRETE CAST AGAINST EARTH 3-INCHES
CONCRETE EXPOSED TO EARTH OR WEATHER 2-INCHES
CONCRETE NOT EXPOSED TO EARTH OR WEATHER 3/4-INCHES
6. ALL REINFORCING SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 GRADE 60 (fy = 60,000 psi)
7. WELDED WIRE FABRIC SHALL BE FURNISHED IN FLAT SHEETS AND SHALL CONFORM TO ASTM A185 (FY = 75 KSI)
AND HAVE A MINIMUM SIDE AND END LAP OF 8 INCHES.
8. THE CONTRACTOR SHALL SUBMIT THE CONCRETE MIX DESIGN(S) TO THE ENGINEER FOR REVIEW. PROPORTION MIX DESIGNS AS DEFINED IN ACI 301 SECTION 4. THE SUBMITTAL SHALL INCLUDE AS A MINIMUM CEMENT TYPE AND SOURCE, CEMENT CUBE STRENGTH, AGGREGATE GRADATIONS, WATER TESTS, AD-MIXTURE CATALOG INFORMATION AND CYLINDER STRENGTH TEST RESULTS FOR THE CONCRETE. THE MIX DESIGN HISTORICAL
RESULTS SHALL ALSO BE SUBMITTED IF APPROPRIATE.
9. ALL REINFORCEMENT TO BE DETAILED, FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS:
"DETAILS AND DETAILING OF CONCRETE REINFORCEMENT", ACI 315 - LATEST REVISION AND "MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES", ACI 315R - LATEST
EDITION.
10. THE CONTRACTOR SHALL PREPARE AND SUBMIT REINFORCEMENT SHOP DRAWINGS TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. THE SHOP DRAWINGS SHALL CLEARLY SHOW ALL REINFORCEMENT LENGTHS AND BENDS, LOCATIONS OF ALL BARS, VIBRATION AND CONSTRUCTION JOINTS. THE DRAWINGS SHALL ALSO INDICATE ALL OPENINGS, SLEEVES, CURBS AND CONCRETE DIMENSIONS IN ACCORDANCE WITH ACI 315.
11. LAPS, ANCHORAGES AND SPLICES SHALL COMPLY WITH THE REQUIREMENTS OF ACI 318-LATEST EDITION, CHAPTER 25. LOCATIONS AND SPLICES SHALL BE IN ACCORDANCE WITH THE CONSTRUCTION JOINT LOCATIONS, DETAILS AND AS SHOWN ON THE REINFORCING STEEL SHOP DRAWINGS.
12. PROVIDE DOWELS OF SAME SIZE AND SPACING AS VERTICAL REINFORCEMENT AT ALL COLUMNS AND WALLS.
13. UNLESS OTHERWISE SHOWN OR NOTED, AS A MINIMUM, PROVIDE TWO #5 BARS (ONE EACH FACE) AROUND UNFRAMED OPENINGS IN SLABS AND WALLS. PLACE BARS PARALLEL TO SIDES OF OPENINGS AND EXTEND
THEM 24 INCHES BEYOND CORNERS.
14. HORIZONTAL WALL REINFORCEMENT SHALL BE CONTINUOUS WITH LAPS COMPLYING WITH THE REQUIREMENTS OF ACI 318-LATEST EDITION CHAPTER 25. UNLESS DETAILED OTHERWISE. CORNER BARS SHALL BE PROVIDED AT ALL CHANGE IN WALL DIRECTIONS AND SHALL BE OF THE SAME SIZE AND SPACING AS THE HORIZONTAL STEEL. EACH CORNER BAR LEG TO PROVIDE A LAP COMPLYING WITH THE REQUIREMENTS OF ACI 318-LATEST EDITION CHAPTER 25. SPLICE UNLESS DETAILED OTHERWISE. EXTEND ALL HORIZONTAL WALLS REINFORCING
THROUGH PIERS.
15. ALL CONSTRUCTION JOINTS SHALL BE FURNISHED WITH KEYWAY CENTERED ON MEMBERS. WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY DEPTH SHALL BE 10% OF THE CROSS SECTION DIMENSION OF
THE MEMBER - MINIMUM 3/4".
16. ANCHOR BOLTS (FURNISHED BY STRUCTURAL STEEL CONTRACTOR) SHALL BE SET USING A TEMPLATE TO WITHIN 1/8" TOLERANCE IN ANY PLAN DIRECTION IN PIERS, FOOTINGS AND FOUNDATION WALLS, WITH THE
MINIMUM PROJECTION AND EMBEDMENT LENGTHS AS INDICATED ON THE DRAWINGS.
17. PROVIDE 3/4" CHAMFER STRIP AT ALL EXPOSED CORNERS OF CONCRETE WALLS AND PIERS.
18. LOCATE ALL SLEEVES, OPENINGS, EMBEDDED ITEMS, ETC., AS INDICATED ON THE DRAWINGS. THE CONCRETE CONTRACTOR SHALL CHECK WITH ALL OTHER TRADES TO MAKE SURE THE SLEEVES, OPENINGS AND EMBEDDED ITEMS THAT ARE TO BE PROVIDED AND SET BY THEM ARE IN PLACE PRIOR TO PLACING OF
CONCRETE IN THE AREA INVOLVED.
19. ALL INTERIOR SLABS ON GRADE SHALL BE PLACED ON A VAPOR BARRIER WITH A MINIMUM OF 4-INCHES CLEAN SAND. MINIMUM REINFORCEMENT SHALL BE IN ACCORDANCE WITH ENGINEERING DATA REPORT CRSI NUMBER 37, "REINFORCING STEEL IN SLAB ON GRADE" OR AS DETAILED. ALL EXTERIOR SLABS ON GRADE SHALL BE PLACED ON A MINIMUM OF 4-INCHES CLEAN SAND. MINIMUM REINFORCEMENT SHALL BE IN ACCORDANCE WITH
ACI 318 SECTION 24.4 - SHRINKAGE AND TEMPERATURE REINFORCEMENT, OR AS DETAILED.
20. CONTRACTORS SHALL OBTAIN APPROVAL FROM THE ENGINEER, PRIOR TO PLACING OPENINGS OR SLEEVES, NOT SHOWN ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBERS, ROOF, WALLS OR FOUNDATIONS.
REVIEW ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR BASES, OPENINGS, SLEEVES, ANCHORS, INSERTS, CONDUITS, RECESSES AND OTHER DEVICES IN CONCRETE WORK BEFORE CASTING
CONCRETE.
21. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR STEEL COLUMNS AND BEAMS AS REQUIRED AND / OR AS CALLED FOR IN THE SPECIFICATIONS EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL
AFTER STEEL ERECTION TO SEAL OPENINGS.
22. REFER TO ARCHITECTURAL DRAWINGS FOR SLAB RECESSES AND/OR FLOOR FINISH MATERIALS.
23. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING SHALL CONFORM
TO AWS D1.4 SPECIFICATION, LATEST EDITION.
24. CONCRETE CONTRACTOR SHALL INCLUDE IN HIS ESTIMATE ADDITIONAL CONCRETE QUANTITY AS REQUIRED TO COMPENSATE FOR DEFLECTIONS OF METAL DECK AND TO PROVIDE A LEVEL CONCRETE SURFACE. REFER TO
STRUCTURAL STEEL AND METAL DECK NOTES FOR ADDITIONAL CONSIDERATIONS.
25. THE CONCRETE SHALL BE THOROUGHLY COMPACTED BY VIBRATION SUPPLEMENTED BY SPADING, PUDDLING OR AGITATION, TO PREVENT HONEYCOMBING AND TO ENSURE THE ELIMINATION OF VOIDS. VIBRATION MUST BE DIRECT ACTION IN THE CONCRETE AND NOT AGAINST FORMS OR REINFORCEMENT. HONEYCOMBING, VOIDS
AND LARGE AIR POCKETS WILL NOT BE ACCEPTABLE.
26. LOCATIONS OF CONTRACTION JOINTS ARE SHOWN ON THE PLAN DRAWING. THE JOINTS SHOWN MAY SERVE AS CONSTRUCTION JOINTS IF CONVENIENT FOR THE CONSTRUCTION SEQUENCE. THE LOCATION OF ANY ADDITIONAL CONSTRUCTION JOINTS PROPOSED BY THE CONTRACTOR SHALL BE SUBJECT TO APPROVAL BY THE ENGINEER. ALL CONCRETE SLABS AND WALLS WITH CONSTRUCTION JOINTS SHALL BE PLACED PER ACI 302.1R.
27. THE USE OF WATER-SOLUBLE CHLORIDE ION SHALL NOT BE USED UNLESS APPROVED BY THE ENGINEER. AS AN ALTERNATIVE TO THE ABOVE, THE CONTRACTOR MAY SUBMIT A CONCRETE MIX DESIGN FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE ALTERNATE MIX DESIGN SHALL BE REVIEWED FOR
CONFORMANCE TO '02 UBC.
FOOTINGS & FOUNDATIONS
1. CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES, AND FIELD
MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO THE ENGINEER.
2. PROVIDE ALL NECESSARY SHEETING, SHORING, BRACING, ETC. AS REQUIRED FOR EXCAVATIONS TO
PROTECT SIDES OF EXCAVATIONS AND ADJACENT STRUCTURES.
3. CONTRACTOR SHALL COMPLY FULLY WITH THE REQUIREMENTS OF MIOSHA, OTHER REGULATORY AGENCIES
AND THE OWNER'S SITE-SPECIFIC SAFETY PLAN AND REGULATIONS FOR SAFETY PROVISIONS.
4. BOTTOM OF FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES, FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING AN ASSUMED MINIMUM
GROSS ALLOWABLE BEARING CAPACITY OF 2000 PSF.
5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED OTHERWISE
ON THE DRAWINGS.
6. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB-GRADE CONTAINING FREE WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING EXCAVATION AFTER SUB-GRADE APPROVAL, THE SUB-GRADE SHALL BE RE-INSPECTED BY THE TESTING LABORATORY AFTER REMOVAL OF
WATER OR FROST.
7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MEASURES TO PREVENT ANY FROST OR ICE FROM PENETRATING ANY FOOTING OR SLAB SUB-GRADE BEFORE AND AFTER PLACING OF CONCRETE UNTIL THE
CONCRETE HAS REACHED ITS' DESIGN STRENGTH.
8. ALL FOUNDATION BEARING SOILS SHALL BE INSPECTED BY A QUALIFIED GEOTECHNICAL ENGINEER. THE TESTING SHALL INCLUDE, BUT NOT BE LIMITED TO, IDENTIFICATION OF SOILS AT AND BELOW THE
FOUNDATION BEARING LEVEL, AND THE ALLOWABLE BEARING CAPACITY.
FABRICATION AND ERECTION
1. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH AISC 303-10
“CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”.
2. ALL HOLES SHALL BE DRILLED OR PUNCHED. NO BURNING OF HOLES WILL BE PERMITTED. SLOTTED HOLES
MUST HAVE STRAIGHT AND SMOOTH SIDES.
3. HOLES SHALL BE SIZED SUCH THAT THEY ARE 116"LARGER IN DIAMETER THAN THE SPECIFIED FASTENER.
4. ALL STRUCTURAL MATERIAL INCLUDING BEAMS, ANGLES AND PLATES TO BE FIELD MEASURED AND FIELD
FABRICATED.
5. IN PLANNING THE METHOD OF ERECTION AND DISTRIBUTION OF MATERIAL BEFORE AND DURING ERECTION, THE CONTRACTOR SHALL MAKE FULL ALLOWANCE FOR ANY OBSTRUCTIONS ENCOUNTERED WHICH MAY RESULT
FROM WORK PERFORMED BY OTHER TRADES, AS WELL AS THE OPERATIONS OF THE OWNER.
6. IT SHALL BE UNDERSTOOD THAT THERE WILL BE NO EXTRA CHARGE BY THE CONTRACTOR ON ACCOUNT OF
ANY OBSTRUCTIONS NOW ON THE SITE OF THE BUILDING.
7. FURNISH AND INSTALL ANY AND ALL NECESSARY TEMPORARY BRACING TO SQUARE AND PLUMB UP ALL WORK, AS REQUIRED, BEFORE BOLTING OR WELDING.
8. IN CASES WHERE MEMBERS DO NOT FIT OR HOLES DO NOT MATCH, THE HOLES SHALL BE REAMED OUT AND THE NEXT LARGER SIZE BOLT INSERTED. IF THE CONNECTION REQUIRES NEW HOLES, THEN NEW HOLES SHALL BE DRILLED. NO SUCH CORRECTIONS SHALL BE MADE WITHOUT PRIOR APPROVAL OF THE OWNER'S RESIDENT
ENGINEER. BURNING OF HOLES IS STRICTLY PROHIBITED.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE CAUSED BY THE ERECTION OF STRUCTURAL STEEL AS HEREIN SPECIFIED. THE CONTRACTOR SHALL REIMBURSE THE OWNER ACTUAL COST OF REPAIR AND
OR REPLACEMENT.
10. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE/DEMOLISH AND PROPERLY DISPOSE OF EXISTING
STEEL, AS REQUIRED FOR THE INSTALLATION OF NEW STEEL.
M
IC
H
IG
AN
D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2025
AT
LA
N
TA
G
AR
AG
E
IN
-G
R O
U N
D H
O
IS
T R
EP
LA
C
EM
EN
T
AT
LA
N
TA
, M
IC
H
IG
AN
FABRICATION AND ERECTION (CONT.)
11. CONTRACTOR IS RESPONSIBLE TO DESIGN, PROVIDE AND INSTALL NECESSARY SHORING DURING DEMOLITION AND REPLACEMENT OF STRUCTURAL STEEL. THE SHORING PLAN SHALL BE DESIGNED AND SEALED BY A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF MICHIGAN.
12. TEMPORARILY SUPPORT ALL EXISTING UTILITIES IN WORK AREA AS REQUIRED TO COMPLETE SCOPE-OF-WORK
ITEMS.
13. PRIOR TO THE COMPLETION OF THE SCOPE OF WORK, INSTALL PERMANENT SUPPORTS TO ALL EXISTING
UTILITIES AFFECTED BY WORK AREA AS REQUIRED TO THE SATISFACTION OF THE OWNER.
HANDLING OF STEEL
1. WHEN THE STRUCTURAL STEEL IS DELIVERED, IT SHALL BE STACKED OFF THE GROUND. CARE SHALL BE TAKEN IN HANDLING AND STACKING THE MEMBERS TO PREVENT BUCKLING, KINKING OR DISTORTION. RAIL AND CARRIER SHIPMENTS SHALL HAVE SUFFICIENT AND SATISFACTORY DUNNAGE TO PREVENT DAMAGE IN TRANSIT.
2. MEMBERS WHICH ARE BENT IN FABRICATION OR IN HANDLING SHALL BE STRAIGHTENED OR REPLACED BEFORE
ERECTION.
3. ALL DIRT, MUD AND DEBRIS SHALL BE CLEANED FROM STEEL BEFORE ERECTION.
WELDING
1. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY AWS D1.1 - LATEST ADOPTION
"STRUCTURAL WELDING CODE-STEEL".
2. FILLER METAL FOR WELDING SHALL BE IN ACCORDANCE WITH SECTION 3, TABLE 3.1., OF THE AWS D1.1
"STRUCTURAL WELDING CODE - STEEL”.
3. ALL WELDED JOINTS SHALL BE MADE USING PRE-QUALIFIED WELDS OR QUALIFIED PER SECTION 4 OF THE AWS D1.1 "STRUCTURAL WELDING…