This package includes construction documents for renovations to the yellow and red entrances at the John D. Dingell VA Medical Center in Detroit, Michigan. The project involves replacing the existing vestibules and entrances to improve accessibility and egress. Drawings cover architectural, mechanical, electrical and fire protection elements. Construction is to follow all applicable state and federal codes. The solicitation number is 36C25023B0007 and is seeking bids for project Z1DA--553-21-206 due by February 28, 2022. The contract will be awarded through the Department of Veterans Affairs.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEDUCTIVE ALTERNATES
REFER TO SECTION 01 00 00 - GENERAL REQUIREMENTS FOR MORE INFORMATION
SOLE SOURCE LIST:
DIVISION ITEM COMPANY
23 09 23 DIRECT DIGITAL CONTROL SYSTEMS HVAC SIEMENS
26 05 19 LOW-VOLTAGE CONTROLS SIEMENS
FLEXIBLE FIRE SPRINKLER HEAD VICLFLEX
07 84 00 HILTI FS HILTI
A101 DEDUCTIVE ALTERNATIVE NO. 1 - DELETE RESIN WALL PANELS
A700 DEDUCTIVE ALTERNATIVE NO. 2 - DELETE EXPANDED AREA OF FLOOR TILE
A121 DEDUCTIVE ALTERNATIVE NO. 3 - DELETE REMOVING COMPLETE YELLOW
ENTRANCE CEILING
A121 DEDUCTIVE ALTERNATIVE NO. 4 - DELETE AIR CURTAIN FROM REVOLVING DOOR
21 13 13
SIGNATURE BLOCK
MEDICAL CENTER DIRECTOR DATE
ASSOCIATE MEDICAL CENTER DIRECTOR DATE
CHIEF, FACILITY MANAGEMENT SERVICES DATE
ASSISTANT CHIEF, FMS DATE
SAFETY AND OCCUPATIONAL HEALTH MANAGER DATE
ENERGY MANAGER DATE
SYSTEMS RESPONSIBILITY MATRIX
DESCRIPTION INSTALLED BYSUPPLIED BY
FURNITURE
ARTWORK
EXTERIOR SIGNAGE
REVOLVING DOORS
SLIDING DOORS
RESIN WALL PANELS
SECURITY SYSTEM - CONDUIT AND BOXES
OWNER OWNER
REMARKS
OWNER OWNER
CONTRACTOR CONTRACTOR
CONTRACTOR CONTRACTOR
CONTRACTOR CONTRACTOR
CONTRACTOR CONTRACTOR
CONTRACTOR CONTRACTOR
SECURITY SYSTEM - CABLE, CABLE INSTALLATION, AND TERMINATIONS CONTRACTOR CONTRACTOR
SECURITY SYSTEM - EQUIPMENT CONTRACTOR CONTRACTOR
FIRE ALARM - CONDUIT, BOXES AND RACEWAYS CONTRACTOR CONTRACTOR
FIRE ALARM - CABLE, CABLE INSTALLATION, AND TERMINATIONS CONTRACTOR CONTRACTOR
CONTRACTOR CONTRACTOR
COMMISSIONING CONTRACTOR CONTRACTOR
FIRE ALARM - EQUIPMENT
COORDINATE FINAL LOCATION W/ COR
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
COVER SHEET REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
G001
G001 COVER SHEET February 11, 2022
G002 GENERAL INFORMATION & SYMBOL LEGEND February 11, 2022
G200 FIRST FLOOR CODE COMPLIANCE PLAN February 11, 2022
AD101 FIRST FLOOR DEMOLITION PLAN February 11, 2022
A001 WALL TYPES February 11, 2022
A101 FLOOR PLANS February 11, 2022
A121 FIRST FLOOR REFELECTED CEILING PLAN February 11, 2022
A200 EXTERIOR ELEVATIONS AND BUILDING SECTIONS February 11, 2022
A420 INTERIOR ELEVATIONS February 11, 2022
A500 DETAILS February 11, 2022
A600 DOOR AND FRAME SCHEDULE February 11, 2022
A700 INTERIOR FINISH KEY & FINISH PLANS February 11, 2022
FX101 FIRE SPRINKLER February 11, 2022
M001 MECHANICAL GENERAL INFORMATION & SYMBOL LEGEND February 11, 2022
MD101 MECHANICAL DEMOLITION PLAN February 11, 2022
MD201 MECHANICAL PIPING DEMOLITION PLAN February 11, 2022
M101 MECHANICAL FLOOR PLAN February 11, 2022
M201 MECHANICAL PIPING FLOOR PLAN February 11, 2022
M500 MECHANICAL DETAILS AND SCHEDULES February 11, 2022
E00 ELECTRICAL SYMBOLS LIST February 11, 2022
E001 ELECTRICAL DEMOLITION PLANS February 11, 2022
E101 ELECTRICAL POWER PLANS February 11, 2022
E201 ELECTRICAL LIGHTING PLANS February 11, 2022
PROJECT TEAM DRAWING SHEET INDEX
ARCHITECTURE/FIRE PROTECTION/M.E.P.
OWNER:
PH: 269.927.0144
ALLIANCE | 7GAE JV
KALAMAZOO, MI 49007
600 E. MICHIGAN AVENUE, SUITE B
4646 JOHN R. STREET
JOHN D. DINGELL VA
MEDICAL CENTER
PROJECT NO. 553-21-206 VA DETROIT RED AND YELLOW ENTRANCES
VA DETROIT HEALTHCARE SYSTEM
DEPARTMENT OF VETERANS AFFAIRS
DETROIT, MICHIGAN
100% CONSTRUCTION
DOCUMENTS
PH: 202.617.8485
ALEXANDRIA, VA 22314
2850 EISENHOWER AVE, SUITE 310
DESCRIPTIONSHEET
PROJECT LOCATION
PROJECT LOCATION
DETROIT, MICHIGAN
NORTH
ISSUE DATE
DETROIT, MI 48201
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
100% Construction Documents - Resubmission 11/15/21
3/24/20212/11/22
A300
A320
A420
A500
ARCHITECTURAL SYMBOLS & PLAN INDICATORS
ABBREVIATIONSBARRIER-FREE DESIGN INFORMATION
ROOMNAME
XXX
A
A
A
A
8'-0"
TOP OF STEEL
ELEV. 10'-0"
A200
TITLE
SCALE X" = 1'-0"
TYP. BARRIER FREE TOILET ROOM FIXTURES
SCALE: NONE
TYP. BARRIER FREE TOILET ROOM FIXTURES
SCALE: NONE
OBSTRUCTED APPROACH
UNOBSTRUCTED APPROACH
DRINKING FOUNTAIN REQUIREMENTS
SCALE: NONE
TYP. CODE REGULATED MOUNTING HEIGHTS
SCALE: NONE
TYP. EQUIPMENT MOUNTING HEIGHTS
SCALE: NONE
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
SECTION INDICATOR
ENLARGED PLAN OR
ELEVATION
PROPOSED SPOT
EXISTING SPOT
ELEVATION
100.57'
100.57'
STRUCTURAL SPAN
ROOF TRUSSES
FLOOR JOIST OR
RAMP
@ 16" O.C.
2 x 12
1" per 12"
SLOPE UP
REVISION TAG W/
REVISION NUMBER
KEYNOTE TAG
WINDOW TAG W/
WINDOW TYPE
INDICATOR
WALL SECTION CUT
COLUMN LINE
WALL TYPES
ELEVATION
BUILDING SECTION CUT
SHEET LOCATION
DETAIL NUMBER
TYPICAL
DIMENSIONING
SET-BACK LINE
PROPERTY LINE
EXISTING
CONTOUR
TOPOGRAPHY
CONTOUR
100'
100'
TOPOGRAPHY
PROPOSED
SECTIONS & DETAILS
TYPICAL TITLE FOR
DOOR NUMBER
DOOR TAG W/
ROOM NUMBER
ROOM NAME/
NORTH ARROW
60" DIAMETER CLEAR
WHEELCHAIR TURNING
SPACE - REFER TO PLAN
- REFER TO PLAN
AND GROUND SPACE
30" x 48" CLEAR FLOOR
CEILING HEIGHT TAG
MIRRORGRAB
BARS
TOILET PAPER
GRAB BARS
5'-0" DIA.
CLEAR FLOOR
SPACE
60" WIDE BY 59" DEEP
CLEAR FLOOR AREA AT
WATER CLOSET
2'-6" x 4'-0"
CLEAR FLOOR
AREA AT SINK
GENERAL NOTES:
ACCESSIBLE CONTROLS, OPERATING
MECHANISMS & HARDWARE SHALL COMPLY
WITH SECTIONS 1109.13 OF THE MBC AND
SECTION 309 OF ICC/ANSI A117.1.
ACCESSIBLE SIGNAGE FURNISHED BY OWNER,
SHALL COMPLY WITH SECTIONS 1110 OF THE
MBC AND SECTION 703 OF ICC/ANSI A117.1.
PORTABLE FIRE EXTINGUISHERS TO BE
PROVIDED IN ACCORDANCE WITH THE 2000
ICC INTERNATIONAL FIRE CODE. MBC (906.1).
REFER TO FLOOR PLAN SHEETS FOR
LOCATIONS OF FIRE EXTINGUISHER CABINETS
(FEC)
ELECTRIC WATER
COOLER
FRONT SIDE
* DIMENSION IS TO BOTTOM
OF REFLECTIVE SURFACE
RECEPTACLE
LIGHT
SWITCH
HVAC
CONTROLS
FIRE
ALARM
FEC
LESS THAN 40#
FEC
GREATER THAN 40#
TEL
PP
RH/CH
GBX
SH1
CL
OT
SPH
CRK SND
PT
SD
HS
XR COM4 MR
CRBG
WP
TP SNR
4'-4"
TV
MOUNTING HEIGHT GENERAL NOTES:
1.
2.
REFER TO INTERIOR ELEVATIONS FOR
ADDITIONAL INFORMATION.
3.
ITEMS ON THIS SHEET ARE NOT NECESSARILY
INCLUDED IN THIS PROJECT.
4.
CONTRACTOR TO VERIFY ALL EQUIPMENT
MOUNTING HEIGHTS WITH OWNER.
REFER TO MECHANICAL/ELECTRICAL
DRAWINGS FOR DEVICE MOUNTING
HEIGHTS.
XXXNORTH
M A
X
IF
B
A R
R
IE
R F
R E E
M
IN
" 4
" 5
M A
X
6" 3' - 0"
1' - 6" 3' - 6"
MIN
1' - 3"
TO
O
R
IF
IC
E
M
IN
6" MIN 11" MIN
8" MIN
TO
O
R
IF
IC
E
M
IN
6" 3' - 0"
M
A X
3' - 6" 1' - 0"
M
IN
M
A X
M
IN
M
IN
M A
X
5' - 0"
SIDE FRONT
M
A X
M
A X
20" - 25"
M
A X
FRONT
M
A X
20" MAX
SIDE
SIDE FRONT
M
IN
M
A X
M
IN
M
A X
@ AT
A/C AIR CONDITIONIN/AIR CONDITIONER
ACOUS ACOUSTICAL
AD AREA DRAIN, AUTOMATIC DAMPER
ADJ ADJUST, ADJUSTABLE
ALUM ALUMINUM
AP ACCESS PANEL
ACT ACOUSTICAL CEILING
B BASE
BAR BARRIER
BD BOARD
BF BARRIER FREE
BKT BRACKET
BLDG BUILDING
BLKG BLOCKING
BOTT BOTTOM
C TO C CENTER TO CENTER
CAB CABINET
CE COLUMN ENCLOSURE
CIR CIRCLE
CIR CIRCUIT
CL CENTER LINE, CLEARANCES
CLG CEILING
CJ CONTROL JOINT
CLKG CAULKING
CLO CLOSET
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CSS CLINICAL SERVICE SINK
CT CERAMIC TILE
CTR CENTER
CUH CABINET UNIT HEATER
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA, D DIAMETER
DIM DIMENSION
DN DOWN
DR DRAIN
DS DOWNSPOUT
ELECT ELECTRICAL
ELEV ELEVATION
ENTR ENTRANCE
EQ EQUAL
EP ELECTRICAL PANEL
EXH EXHAUST
EXP EXPOSED
EXIST EXISTING, EXSIST'G
EXT EXTERIOR
EW EACH WAY
FA FIRE ALARM
FD FIRE DAMPER OR FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FL, FLR FLOOR FINISH
FLG, FLRG FLOORING, FLOOR'G
FURN FURNITURE, FURNACE
FWC FABRIC WALL COVERING
FT FEET, FOOT
GALV GALVANIZE(D)
GL GLASS
GSB GYPSUM SHEATHING BOARD
GWB GYPSUM WALLBOARD
GYP. BD GYPSUM BOARD
ID INSIDE DIAMETER
INSUL INSULATION
IN INCH(ES)
JAN JANITOR'S CLOSET
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
HW HEADWALL
LAM LAMINATED
LF LINEAL FEET
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MANUF MANUFACTURED, MANUFACTURER
MIN MINIMUM
MLD'G MOLDING
MTL METAL
N NORTH
NAT NATURAL
NIC NOT IN CONTRACT
NORM NORMAL
NTS NOT TO SCALE
O.C. ON CENTER
OPN'G OPENING
O, O2 OXYGEN
PLAST PLASTIC
PNT PAINT
PREFAB PREFABRICATED
PLYWD PLYWOOD, PLYW'D
R RADIUS
RA RETURN AIR
REQ'D REQUIRED
RM ROOM
S SINK, SOUTH, SHINGLE
SA SUPPLY AIR
SAN SANITARY
SMKD SMOKE DAMPER
SECT SECTION
SHWR SHOWER
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SS SERVICE SINK, STAINLESS STEEL
STD STANDARD
STOR STORAGE
SUSP SUSPEND(ED)
SYM SYMBOL, SYMMETRICAL
TOIL TOILET
TYP TYPICAL
UNFIN UNFINISHED
UTIL UTILITY
VAC VACUUM
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE
VD VOLUME DAMPER
VERT VERTICAL
V.I.F. VERIFY IN FIELD
VT VINYL TILE
VWC VINYL WALL COVERING
W/ WITH
WC WATER CLOSET
WD WOOD
WNDW WINDOW
W. HTR WATER HEATER
W/O WITHOUT
WP WALL PROTECTION
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
GENERAL INFORMATION &
SYMBOL LEGEND
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
G002
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
Emergency Egress Capacity (Width):
Existing Vestibule configuration:
Sliding Doors: 8'-0" wide breakout door
8'-0" wide breakout door
Revolving Door: 3'-0" (not ADA compliant)
Total Width: 16'-0" ADA Compliant
Proposed Vestibule Configuration:
Sliding Door: 9'-8" wide breakout door
Revolving Door: 7'-2" wide breakout door
Total Width: 16'-10" ADA Compliant
152 SF
CB102
VESTIBULE
/4
Emergency Egress Compacity (width):
Existing Vestibule configuration:
Sliding Doors: 6'-6" wide breakout door
6'-6" wide breakout door
Revolving Door: 3'-0" door (not ADA compliant)
Total Egress Width: 13'-0" ADA compliant
Proposed Vestibule Configuration:
Sliding Doors: 7'-8" wide breakout door
Revolving Door: 7'-2" wide breakout door
Total Egress Width: 14'-10" ADA compliant
118 SF
CA152
VESTIBULE
7' - 2 1/4"
7' - 8 1/2"
CODE COMPLIANCE LEGEND
1-HOUR FIRE RATED PARTITION - UL DES U419
2-HOUR FIRE RATED BARRIER - UL DES U419
1-HOUR SMOKE BARRIER - NFPA 101 - 8.3
3-HOUR FIRE RATED BARRIER - UL DES U419
4-HOUR FIRE RATED BARRIER - UL DES U419
ROOM NAME
XXX SF
ROOM NAME
ROOM NUMBER
ROOM AREA
CODE ROOM TAG INFORMATION
PATH OF EGRESS
EXIT
OCCUPANT LOAD PER EXIT
OCCUPANT LOAD
EGRESS CORRIDOR
ROOM OCCUPANT LOADXX
APPLICABLE CODES AND STANDARDS
APPLICABLE CODES/EDITION
BUILDING CODES:
2021 - INTERNATIONAL BUILDING CODE
2021 - NFPA 101 LIFE SAFETY CODE
2021 - NFPA 220 STANDARD ON TYPES OF BUILDINGS
BARRIER FREE CODES:
2021 - INTERNATIONAL BUILDING CODE
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS WITH THE DEPARTMENT OF VETERANS
AFFAIRS BARRIER FREE DESIGN GUIDE (A SUPPLEMENT)
PLUMBING CODE:
2021 - INTERNATIONAL PLUMBING CODE
FIRE PREVENTION CODE:
2021 - NFPA 1: UNIFORM FIRE CODE
MECHANICAL CODE:
2021 - INTERNATIONAL MECHANICAL CODE
2015 - ASME BOILER AND PRESSURE VESSEL CODE
2012 - ASME PRESSURE PIPING CODE
2016 - ASHRAE STANDARD 62.1 - VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
2013 - ASHRAE STANDARD 15 - SAFETY STANDARD FOR REFRIGERATION SYSTEMS
ELECTRICAL CODE:
2021 - MICHIGAN ENERGY CODE
2020 - NFPA (NATIONAL ENERGY CODE)
VAMC DETROIT ELECTRICAL STANDARDS
ENERGY CODE:
2019 - ASHRAE STANDARD 90.1 - ENERGY STANDARD FOR BUILDINGS
THE PRIMARY CODE USED FOR THIS SUMMARY IS NFPA 101 LIFE SAFETY CODE 2021,
THE IBC 2021 IS ONLY USED WHEN NFPA 101 IS SILENT ON THE SUBJECT MATTER.
CODE ANALYSIS
DESCRIPTIONITEM CODE REFERENCE
OCCUPANCY: HEALTH CARE (I-2 - HOSPITALS)1. LIFE SAFETY: 6.1
IBC: SECT. 308
PROJECT AREA: 1,660 S.F.
NEW CONSTRUCTION 0 S.F.
RENOVATION 1,660 S.F.
2.
NUMBER OF EXISTING STORIES: ABOVE GRADE: 14 (INCLUDING
INTERSTITIAL SPACES)
BELOW GRADE: 1
3.
CONSTRUCTION TYPE: II (222) LIFE SAFETY: 19.1.6.4 &
18.1.6.4
4.
ACTUAL CONSTRUCTION:
NON-COMBUSTIBLE: STEEL STRUCTURE. NEW NON-BEARING INTERIOR METAL STUD
PARTITIONS.
LIFE SAFETY:
9.7.1.1
5.
SPRINKLER SYSTEM:
EXISTING NFPA 13 SPRINKLER SYSTEM INSTALLED THROUGHOUT. RENOVATIONS
ARE TO ALSO BE SPRINKLED THROUGHOUT.
LIFE SAFETY:
9.6
6.
FIRE ALARM SYSTEMS:
RENOVATION TO TIE INTO EXISTING FIRE ALARM SYSTEMS.
LIFE SAFETY:
7.3.1.2
7.
OCCUPANT LOAD FOR EGRESS BASED ON SF/PERSON (UNO):
LIFE SAFETY:
7.3.1.2
8.
OCCUPANCY LOAD EGRESS CAPACITY
ASSEMBLY - LESS
CONCENTRATED LOBBY
1/15 S.F. 1,500 - EXISTING
ASSEMBLY - CONCENTRATED 1/7 S.F. 1,800 - NEW LOBBY
WAITING 1/5 S.F. NET
EXISTING AREA TO REMAIN UNCHANGED
HAZARDOUS SUBSTANCES:
DESIGNATED SUBSTANCE REMOVAL & ABATEMENT PERFORMED UNDER SEPARATE
CONTACT PRIOR TO START OF PROJECT.
LIFE SAFETY:
19.2.5.6.3.3 & 18.2.5.6.3.3 9.
OPENING PROTECTIVES IN FIRE RATED SMOKE BARRIERS:
45 MIN. IN 1HR RATED WALLS GENERAL
90 MIN. IN 2HR RATED WALLS STAIRS
45 MIN. IN 1HR RATED WALLS
NOT PERMITTED IN 1HR RATED WALLS FOR STAIRS
100 SQ. IN. MAX FOR WINDOWS IN DOORS FOR 60 MIN. DOORS
DOORS:
WINDOWS:
MAINTAIN EXISTING 2 HOUR FLOOR/CEILING RATING AS AFFECTED BY DEMOLITION AND
NEW WORK.
11.
10.
DEAD END CORRIDORS: 30' MAX LIFE SAFETY:
18.2.5.2 12.
AREAS TO BE SEPARATED:
BOILER ROOMS - 1 HOUR
SOILED LINEN - 1 HOUR
STORAGE ROOMS >/= 100 S.F. - 1 HOUR
SMOKE BARRIER - 1 HOUR
CLEAN LINEN - 1 HOUR
13. LIFE SAFETY:
18.4.3.5
18.4.3.5
18.4.3.5
18.3.7
18.4.3.5
18.3.7SMOKE COMPARTMENT SIZE - 22,500 S.F. MAX
ENERGY
CENTER
NORTH
PARKING
DECK
SOUTH
PARKING
DECK
4 3
8 7
2 1
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
FIRST FLOOR CODE
COMPLIANCE PLAN
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
G200
NORTH
SCALE: 1/4" = 1'-0"
1ST FLOOR
CODE
COMPLIANCE
RED
NORTH
SCALE: 1/4" = 1'-0"
1ST FLOOR
CODE
COMPLIANCE
YELLOW
PLAN NORTH
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
J.4
K.2
7' - 0"
3' - 0"
AD101 3
F
F
F
F
F
F
17 1516
M
L
2 2 2
2 2
3 3
4' - 4" 20' - 8" 20' - 8" 4' - 4"
16.9 15.1
4' - 0 1/8"
N
N.2
19' - 0"
23' - 0"
8 8
AD101
3 3
F
F
F
F
F F
GENERAL DEMO NOTES
1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED
TO WHAT IS SHOWN ON THE DEMOLITION PLANS. THE INTENT IS
TO REMOVE ALL MATERIALS AND ITEMS AS REQUIRED TO
FACILITATE NEW CONSTRUCTION.
2. CONTRACTORS ARE TO VERIFY FIELD CONDITIONS, IF
CONDITIONS DO NOT REFLECT WHAT IS NOTED IN THE
CONTRACT DOCUMENTS, THE CONTRACTOR IS TO NOTIFY THE
ARCHITECT.
3. THIS PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET
OF CONSTRUCTION DOCUMENTS. DO NOT REMOVE ANY ITEMS
WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL
TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT.
4. CONTRACTOR TO USE CONSTRUCTION DUMPSTERS PROVIDED
BY THE VA LOCATED AT THE LOWER LEVEL LOADING DOCK.
5. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL
DEMOLISHED MATERIALS. DO NOT ALLOW MATERIALS AND
DEBRIS GENERATED BY DEMOLITION ACTIVITIES TO
ACCUMULATE ON THE JOBSITE. REMOVE DAILY AND DISPOSE
OF IN A LEGAL MANNER. NO ONSITE SALE OR BURNING OF
REMOVED ITEMS IS PERMITTED.
6. THE CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS
TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON
THE SITE TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON
ON, ABOUT OR ADJACENT TO THE PREMISES. THE CONTRACTOR
SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES AND
REGULATIONS PERTAINING TO SAFETY AND THE PREVENTION OF
ACCIDENTS.
7. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT,
INSULATION, WATERPROOFING, EMERGENCY LIGHTING,
SECURITY, ALARMS, ETC. FOR ALL OR PART OF ITEMS WHICH
ARE TO REMAIN.
8. THE OWNER RESERVES THE RIGHTS TO ANY REMOVED
MATERIALS OR ITEMS. CONTRACTOR TO COORDINATE WITH
OWNER.
9. DO NOT CUT AND/OR PATCH STRUCTURAL ELEMENTS IN A
MANNER THAT COULD CHANGE THEIR LOAD-CARRYING
CAPACITY OR LOAD-DEFLECTION RATIO.
10. PATCH/REPAIR OR REPLACE ALL AREAS DAMAGED BY
DEMOLITION, REWORK AS REQUIRED, PREPARE FOR NEW
CONSTRUCTION AS REQUIRED. BRICK OR BLOCK PATCHING
SHALL BE TOOTHED-IN TO MATCH EXISTING COURSING
PATTERN.
11. WHERE WALLS & CEILINGS ARE TO BE REMOVED, ALL ITEMS
THAT FALL WITH THE WALLS &/OR CEILINGS ARE TO BE
REMOVED OR REROUTED. REFER TO MECHANICAL, ELECTRICAL,
AND PLUMBING PLANS FOR ADDITIONAL DEMOLITION NOT
SHOWN ON THIS SHEET.
12. CONSTRUCTION AREAS TO BE COMPLETELY SEPARATED FROM
OCCUPIED AREAS WITH A ONE-HOUR FIRE RATED ASSEMBLY,
AND WITH SUITABLE DUST BARRIER. TEMPORARILY SEAL OFF ALL
RETURN & SUPPLY AIR DIFFUSERS IN CONSTRUCTION AREA.
PROVIDE RECIRCULATING HEPA FILTER IN CONSTRUCTION
AREA. ALL DEMOLISHED MATERIAL IS TO BE REMOVED FROM
SITE IN A COVERED CONTAINER. NEGATIVE AIR PRESSURE TO BE
MAINTAINED WITHIN CONSTRUCTION ZONE.
13. IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING
DEMOLITION, CONTRACTOR SHALL CONTACT OWNER FOR
ABATEMENT.
14. REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND
SURFACES CUT OR DAMAGED DURING DEMOLITION, BY
METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING
WARRANTIES.
15. CLEAN AREAS AND SPACES WHERE CUTTING AND PATCHING
ARE PERFORMED.
16. INTERIOR WALLS TO BE REMOVED, SHALL BE REMOVED THE
ENTIRE HEIGHT OF THE WALL UNLESS REQUIRED OTHERWISE BY
NEW OPENINGS IN EXISTING WALLS TO REMAIN.
17. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ALL APPLIED
FIREPROOFING MATERIAL IN AREAS LEFT UNPROTECTED DUE TO
REMOVAL OF EXISTING ELEMENTS OR AREAS DAMAGED
DURING NEW WORK AND DEMOLITION. MATCH EXISTING
FIREPROOFING MATERIAL TYPE AND THICKNESS TO MAINTAIN
REQUIRED LEVEL OR PROTECTION.
DEMOLITION KEY NOTES
REMOVE EXISTING WALL CONSTRUCTION AS SHOWN.
PATCH & REPAIR ADJACENT SURFACES TO REMAIN AS
NECESSARY TO PREPARE FOR NEW CONSTRUCTION
AND/OR NEW FINISHES.
REMOVE & SALVAGE EXISTING DOOR(S), FRAME(S),
HARDWARE, ETC. TURN OVER TO OWNER UNLESS
DIRECTED OTHERWISE.
REMOVE EXISTING PAINT FINISHES, CERAMIC WALL
BASE, AND ALL ITEMS ATTACHED TO THE WALLS. TURN
OVER TO OWNER, UNLESS DIRECTED OTHERWISE.
PATCH & REPAIR EXPOSED SURFACES TO REMAIN AS
REQUIRED FOR NEW CONSTRUCTION AND/OR NEW
FINISHES.
REMOVE EXISTING FLOORING AND FLOOR FINISHES
INCLUDING ALL ADHESIVES, SETTING MATERIALS
DOWN TO EXISTING SUBSTRATE. GRIND CONCRETE
FLOORS AS REQUIRED TO PROVIDE A SMOOTH AND
UNIFORM SURFACE FOR NEW FINISHES.
REMOVE EXISTING DRYWALL CEILING AND SUPPORT
SYSTEM. PATCH & REPAIR EXPOSED SURFACES TO
REMAIN AS REQUIRED FOR NEW CONSTRUCTION
AND/OR NEW FINISHES.
SAWCUT FLOOR SLAB AT LINE OF NEW STOREFRONT
AND DOOR UNIT.
EXISTING WALL MOUNTED ITEMS (SIGNAGE, PHOTO
BOARDS ETC.) TO BE REMOVED, SALVAGED, & RE-
INSTALLED BY CONTRACTOR.
BUILD NEW TEMPORARY INFECTION CONTROL
BARRIER WALLS BEFORE COMMENCING DEMOLITION
WORK. CLOSE CEILING ABOVE TRIANGLE AREAS IN
YELLOW ENTRANCE. REFER TO WALL TYPE F ON A001.
REMOVE EXISTING CEILING ACCESS PANEL.
EXISTING FIRE PUSH/PULL DEVICE WILL BE RELOCATED.
ELEV. 658' - 0"
1ST FLOOR
ELEV. 658' - 0"
1ST FLOOR
2 2
ENERGY
CENTER
NORTH
PARKING
DECK
SOUTH
PARKING
DECK
4 3
8 7
2 1
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
FIRST FLOOR DEMOLITION
PLAN
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
AD101
SCALE: 1/4" = 1'-0"AD101
1ST FLOOR DEMOLITION - RED ENTRANCE02
SCALE: 1/4" = 1'-0"AD101
1ST FLOOR DEMOLITION - YELLOW ENTRANCE01
SCALE: 1/4" = 1'-0"AD101
RED ENTRANCE DEMO ELEVATION3
SCALE: 1/4" = 1'-0"AD101
YELLOW ENTRANCE DEMO ELEVATION4 PLAN NORTH
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
(1) LAYER OF 5/8" GYP. BD. ON
COLD FORMED METAL STUDS @ 16"
O.C. (MAX.); WRAP GYP. BD.
AROUND ENDS/ CORNERS WHERE
EXPOSED
CEILING LINE
FLOOR LINE
UNDERSIDE OF DECK
STEEL STUD DEFLECTION
TRACK ANCHORED TO DECK
REFERENCE FINISH SCHEDULE
FOR BASE MATERIAL
STEEL STUD CHANNEL
RUNNER FASTENED TO FLOOR
/2
PLAN
TYPE STUD SIZE
PARTITION
WIDTH
FIRE RATING
3-5/8" 4-1/4" -A4
BACKER ROD AND SEALANT
BACKER ROD AND SEALANT
NEW GYP CEILING ON
EXISTING METAL STUDS
3/4" MDF BACKER WITH FRENCH
CLEAT ATTACHED TO 7/8" STEEL HAT
CHANNELS @ 16" O.C. (MAX.)
ATTACHED TO EXISTING BRICK
VENEER WALL
CEILING LINE
FLOOR LINE
UNDERSIDE OF DECK
REFERENCE FINISH SCHEDULE
FOR BASE MATERIAL
PLAN
TYPE CHANNEL SIZE
PARTITION
WIDTH
FIRE RATING
7/8" 2-5/8"B1
BACKER ROD AND SEALANT
EXISTING BRICK VENEER WALL
NEW GYP CEILING ON
EXISTING METAL STUDS
RES-1, 1/4" RESIN WITH
DADO WHERE IT MEETS THE
MDF
UNDERSIDE OF
EXISTING CEILING
TEMPORARY PARTITION. HI-
IMPACT 5/8" GYP. BOARD
ON 3-5/8" METAL STUDS.
FINISH OCCUPIED SIDE PER
ROOM FINISH SCHEDULE
NOTE:
PLASTER TAPE ALL GYP. BD.
JOINTS; SECURE ALL TAPE
WITH RAM-TACK HIGH TACK
SPRAY OR EQUAL;
CONTRACTOR TO PROVIDE
FINISH WALL ON OCCUPIED
SIDE TO GIVE FINISHED
APPEARANCE; REFER TO
PHASING PLANS FOR
ADDITIONAL INFORMATION
OCCUPIED SIDERENOVATION SIDE
MECHANICALLY
FASTEN BOTTOM
TRACK TO FLOOR
(1) LAYER OF 5/8" GYP. BD. ON
COLD FORMED METAL STUDS @ 16"
O.C. (MAX.); WRAP GYP. BD.
AROUND ENDS/ CORNERS WHERE
EXPOSED
CEILING LINE
FLOOR LINE
UNDERSIDE OF DECK
STEEL STUD DEFLECTION
TRACK ANCHORED TO DECK
REFERENCE FINISH SCHEDULE
FOR BASE MATERIAL
STEEL STUD CHANNEL
RUNNER FASTENED TO FLOOR
/2
PLAN
TYPE STUD SIZE
PARTITION
WIDTH
FIRE RATING
3-5/8" 5-5/8" -C1
BACKER ROD AND SEALANT
BACKER ROD AND SEALANT
NEW GYP CEILING ON
EXISTING METAL STUDS
FILL ENTIRE CAVITY WITH
SOUND BATT INSULATION
METAL SIDING/PANEL
(1) LAYER OF 5/8" GYP. BD. ON
COLD FORMED METAL STUDS @ 16"
O.C. (MAX.); WRAP GYP. BD.
AROUND ENDS/ CORNERS WHERE
EXPOSED
CEILING LINE
FLOOR LINE
UNDERSIDE OF DECK
STEEL STUD DEFLECTION
TRACK ANCHORED TO DECK
STEEL STUD CHANNEL
RUNNER FASTENED TO FLOOR
PLAN
TYPE STUD SIZE
PARTITION
WIDTH
FIRE RATING
3-5/8" 4-1/4" -D1
BACKER ROD AND SEALANT
NEW GYP CEILING ON
EXISTING METAL STUDS
3/4" MDF BACKER WITH FRENCH
CLEAT ATTACHED TO 7/8" STEEL HAT
CHANNELS @ 16" O.C. (MAX.)
ATTACHED TO EXISTING BRICK
VENEER WALL
REFERENCE FINISH SCHEDULE
FOR BASE MATERIAL
RES-1, 1/4" RESIN WITH DADO
WHERE IT MEETS THE MDF
CEILING LINE
FLOOR LINE
UNDERSIDE OF DECK
PLAN
TYPE CHANNEL SIZE
PARTITION
WIDTH
FIRE RATING
7/8" 1-1/2"E1
EXISTING BRICK VENEER WALL
(1) LAYER OF 5/8" GYP. BD. ON
COLD FORMED METAL STUDS @ 16"
O.C. (MAX.); WRAP GYP. BD.
AROUND ENDS/ CORNERS WHERE
EXPOSED
REFERENCE FINISH SCHEDULE
FOR BASE MATERIAL
BACKER ROD AND SEALANT
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
WALL TYPES REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
A001
1 1/2" = 1'-0"A Wall Type A 1 1/2" = 1'-0"B Wall Type B
1 1/2" = 1'-0"F WALL TYPE F - TEMPORARY CONSTRUCTION WALL
1 1/2" = 1'-0"C Wall Type C
1 1/2" = 1'-0"D Wall Type D 1 1/2" = 1'-0"E Wall Type E
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
A200 06
J.4
K.2
26 25
B1300
WOMENS TOILET
B1301
MENS TOILET
CB102
VESTIBULE
A42004
A200
AFTER HOUR
CALL BOX
B1
B1
B1
C1
A500
A500
102B102A
EXISTING COLUMN
13' - 8"
A200
2' - 5"
A500
A420
282 SF
CB103
RED ENTRANCE HALL
45.00°
.0
.0
CG
CG
A500
A500
REVOLVING DOOR
A500
A500
A4
D
E1
E1
EXISTING COLUMN
SIM.
SIM.
.0
A500
A500
SIM.
1 1
C1
M
L
SA105
STAIRS #05
SA103
STAIRS #03
106 SF
CA137
VESTIBULE
CA138
VESTIBULE
CA152
VESTIBULE
2' - 10 5/8" 21' - 0" 2' - 10 5/8"
A200
AFTER HOUR
CALL BOX
B1
A420
A500
A500
A200
653 SF
CA153
YELLOW ENTRANCE
HALL
152B
A420
CG
CG
CG
CG
16.9 15.1
N
N.2
A500
A500
A500
B1
A500
REVOLVING DOOR
A500
A4
D
C1
C1152A
B1
E1
E1
CG CG
45.00°
135.00°
135.00°
A500
SIM.
A500
SIM.
A500
SIM.
135.00°
FLOOR PLAN LEGEND
EXISTING NON-FIRE RATED WALL
NEW NON-FIRE RATED WALL
EXISTING DOOR
NEW DOOR
1-HOUR FIRE RATED PARTITION - UL DES U419
2-HOUR FIRE RATED BARRIER - UL DES U419
1-HOUR SMOKE BARRIER - NFPA 101 - 8.3
AREA NOT IN SCOPE
KEYNOTES
CONTINUE CONTROL JOINT INTO NEW
CONCRETE.
EXISTING ELECTRICAL PANEL
SLOPE CONCRETE 1/16" PER FOOT AWAY
FROM BUILDING.
GENERAL NOTES
1. THIS FLOOR TO BE SEPARATED FROM FLOORS ABOVE &
BELOW BY 2-HR SEPARATION. CONTRACTOR TO FILL GAP AT
EXTERIOR WALL W/ FIRE CAULK.
2. ALL WALLS ARE WALL TYPE UNLESS NOTED OTHERWISE.
3. PROVIDE UL RATED WALLS WHERE SHOWN. REFER TO WALL
TYPES FOR WALL CONSTRUCTION.
4. PROVIDE BLOCKING IN WALLS FOR OWNER PROVIDED
EQUIPMENT AS SHOWN ON ON INTERIOR ELEVATIONS.
COORDINATE FINAL LOCATIONS WITH OWNER.
5. FILL FLOOR WITH +/- 2" CONCRETE WHERE EXISTING WALK
OFF MATS WERE REMOVED. CREATE LEVEL SURFACE TO
ENSURE FLUSH FINISH WITH ADJOINING TILE FLOORS.
6. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ALL
APPLIED FIREPROOFING MATERIAL IN AREAS LEFT
UNPROTECTED DUE TO REMOVAL OF EXISTING ELEMENTS
OR AREAS DAMAGED DURING NEW WORK AND
DEMOLITION. MATCH EXISTING FIREPROOFING MATERIAL
TYPE AND THICKNESS TO MAINTAIN REQUIRED LEVEL OR
PROTECTION.
A4
DEDUCT ALTERNATES
REFER TO SECTION 01 00 00 - GENERAL REQUIREMENTS FOR
MORE INFORMATION
A101 DEDUCTIVE ALTERNATIVE NO. 1 - DELETE RESIN
WALL PANELS
A700 DEDUCTIVE ALTERNATIVE NO. 2 - DELETE
EXPANDED AREA OF FLOOR TILE
A121 DEDUCTIVE ALTERNATIVE NO. 3 - DELETE
REMOVING COMPLETE YELLOW ENTRANCE
CEILING
A121 DEDUCTIVE ALTERNATIVE NO. 4 - DELETE AIR
CURTAIN FROM REVOLVING DOOR
ENERGY
CENTER
NORTH
PARKING
DECK
SOUTH
PARKING
DECK
4 3
8 7
2 1
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
FLOOR PLANS REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
A101
NORTH
SCALE: 1/4" = 1'-0"
FIRST FLOOR
RED ENTRANCE
NORTH
SCALE: 1/4" = 1'-0"
FIRST FLOOR
YELLOW
ENTRANCE
PLAN NORTH
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
S
F
S
S
REFLECTED CEILING PLAN LEGEND
AREAS TO BE SUSPENDED ACOUSTIC TILE
AREAS OF EXISTING SUSPENDED ACOUSTIC TILE
TO BE REWORKED DUE TO NEW CONSTRUCTION.
AREAS TO FINISHED GYPSUM BOARD CEILING
FLUORESCENT LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS
SUPPLY DIFFUSER - SEE MECHANICAL
DRAWINGS
EXHAUST DIFFUSER - SEE MECHANICAL
DRAWINGS
INDUSTRIAL LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS
CEILING MOUNTED EXIT SIGN - SEE ELECTRICAL
DRAWINGS
PENDANT LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS
RECESSED LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS
CEILING HEIGHT ABOVE FINISHED FLOOR8'-0"
GENERAL NOTES - CEILING PLAN
1. ELECTRICAL AND MECHANICAL FIXTURES AND DUCTWORK ARE
SHOWN FOR REFERENCE ONLY. REFER TO MECHANICAL AND
ELECTRICAL DRAWINGS.
2. REFER TO FINISH SCHEDULE FOR CEILING FINISHES.
RETURN AIR DIFFUSER - SEE MECHANICAL
DRAWINGS
RADIANT CEILING PANELS, SEE MECHANICAL
DRAWINGS
EXP.
EXPOSED STRUCTURE
EXISTING CEILING HEIGHT - NO CHANGEEXIST.
CEILING HEIGHT ABOVE FINISHED FLOOR -
MATCH EXISTING; FIELD VERIFY
VERIFY
WIRELESS ACCESS POINT - SEE ELECTRICAL
DRAWINGS
KEYNOTES
1 MATCH ADJACENT EXISTING CEILING TEXTURE.
SPEAKER
S
DEDUCT ALTERNATES
REFER TO SECTION 01 00 00 - GENERAL REQUIREMENTS FOR
MORE INFORMATION
A101 DEDUCTIVE ALTERNATIVE NO. 1 - DELETE RESIN
WALL PANELS
A700 DEDUCTIVE ALTERNATIVE NO. 2 - DELETE
EXPANDED AREA OF FLOOR TILE
A121 DEDUCTIVE ALTERNATIVE NO. 3 - DELETE
REMOVING COMPLETE YELLOW ENTRANCE
CEILING
A121 DEDUCTIVE ALTERNATIVE NO. 4 - DELETE AIR
CURTAIN FROM REVOLVING DOOR
J.4
K.2
26 25
152 SF
CB102
VESTIBULE
4 5/8"
.0
10' -
3/4
8' - 4"
.0
9' - 0"
9' - 0"
EQ
EQ
EQ
3' - 6"
3' - 6"
8' - 4"
2' - 0"
282 SF
CB103
RED ENTRANCE HALL
LIGHTING AND AIR
CURTAIN INTEGRAL IN
REVOLVING DOOR UNIT
A500
NEW ACCESS PANEL
EXTEND CROWN MOLDING
AROUND BRICK COLUMN
EXTEND CROWN
MOLDING AROUND
BRICK COLUMN
NEW CORNICE;
PROFILE AND FINISH
TO MATCH EXISTING
NEW CORNICE;
PROFILE AND FINISH
TO MATCH EXISTING
A500 2
/2
1' - 11 1/4"
2'
7/
8"
1' - 0 1/8"
/2
4'
/8
4'
/8
/8
/8
M
L
118 SF
CA152
VESTIBULE
8' - 6"
8' - 6"
4'
6"
4'
6"
4'
6"
3'
6"
3'
6"
10' - 9"
16.9 15.1
N
N.2
653 SF
CA153
YELLOW ENTRANCE
HALL
LIGHTING AND AIR
CURTAIN INTEGRAL IN
REVOLVING DOOR UNIT
NEW ACCESS PANEL
8' - 4"
8' - 4"
8' - 6"
3' - 0 3/8" 2' - 5"
1' - 2 1/2"
1' - 10 7/8"
4'
3/
8"
8'
3" 4' - 5 1/8"
5'
1/
4"
1' - 8"
10 3/4"
3' - 6 1/2"
2' - 1 5/8"
1' - 10 5/8"
2' - 0"
4' - 1 3/8" 3' - 4 1/2"
1 3/8" 1' - 7 1/4"
1' - 9 3/8"
11 1/4"
1' - 8"
6 3/4"
/4
A500
A500
SIM.
ENERGY
CENTER
NORTH
PARKING
DECK
SOUTH
PARKING
DECK
4 3
8 7
2 1
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
FIRST FLOOR REFELECTED
CEILING PLAN
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
A121
NORTH
SCALE: 1/4" = 1'-0"
1ST FLOOR RED
RCP
NORTH
SCALE: 1/4" = 1'-0"
1ST FLOOR
YELLOW RCP
PLAN NORTH
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
M L
118 SF
CA152
VESTIBULE
Proposed New
Sliding Door In
Aluminum Frame
System
After Hour
Call Box
With Signage
New Ceiling to accommodate new Lighting and
HVAC Layout
Proposed new tile flooring.
Existing Concrete
Floor Deck.
A500
SIM.SIM.
653 SF
CA153
YELLOW ENTRANCE
HALL
Existing electrical panels to remain.
A500
Existing mechanical grille Infill at existing recessed slab to receive new floor finishes.
152 SF
CB102
VESTIBULEEXTERIOR
CANOPY
A500
Proposed New Sliding Door in Aluminum Frame System
New Ceiling to accommodate new Lighting and
HVAC Layout
After Hour
Call Box
With Signage
New tile flooring.
Align new and existing ceilings
Existing exterior concrete to remain.
Mechanical Space
DECORATIVE TILE
WALL PROTECTION
REFER 1/A420
282 SF
CB103
RED ENTRANCE HALL
A500
A600
Infill at existing recessed slab to receive new floor finishes.
282 SF
CB103
RED ENTRANCE HALL
EXTERIOR
CANOPY
REVOLVING DOOR
A600
Infill at existing recessed slab to receive new floor finishes.
ELEV. 669' - 5"
INTERSTICE 01
M
653 SF
CA153
YELLOW ENTRANCE
HALL
EXTERIOR
CANOPY
REVOLVING DOOR
Infill at existing recessed slab to receive new floor finishes.
A600
ELEV. 658' - 0"
1ST FLOOR
A200
A200
SLIDING DOOR REVOLVING DOOR
A200
1ST FLOOR
658' - 0"
A200
ALUMINUM FRAMED
STOREFRONT SYSTEM W/
1" INSULATED GLAZING
SLIDING DOOR REVOLVING DOOR
LAMINATED
GLAZING UNIT
2' - 5"
SPANDREL
PANEL
LAMINATED
GLAZING UNIT
SPANDREL
PANEL
LAMINATED
GLAZING UNIT
19' - 11 1/2"
3" 7' - 7 1/2" 3" 5' - 8 3/4" 3" 5' - 7 1/4" 3"
3"
9' - 7 1/8" 3"
4' - 1 1/2" 2" 4' - 2" 2" 4' - 1 7/8"
3"
23' - 1 5/8"
FLOOR LINE
1 2 3
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
EXTERIOR ELEVATIONS AND
BUILDING SECTIONS
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
A200
SCALE: 1/4" = 1'-0"A200
YELLOW ENTRANCE SECTION01
SCALE: 1/4" = 1'-0"A200
RED ENTRANCE SECTION03
SCALE: 1/4" = 1'-0"A200
RED ENTRANCE SECTION04
SCALE: 1/4" = 1'-0"A200
YELLOW ENTRANCE SECTION02
SCALE: 1/4" = 1'-0"A200
YELLOW ENTRANCE EXTERIOR ELEVATION05
SCALE: 1/4" = 1'-0"A200
RED ENTRANCE EXTERIOR ELEVATION06
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
282 SF
CB103
RED ENTRANCE HALL
TILE WALL BASE; WB-1
Hancock Exit
RESIN PANEL; RES-1
DIMENSIONAL
METAL LETTERS
P-1
P-2
P-2
P-1
TILE WALL BASE; WB-1
SLIDING DOORREVOLVING DOOR
A500
A500
A420
TILE WALL BASE; WB-1
P-2
P-1
282 SF
CB103
RED ENTRANCE HALL
RESIN PANEL; RES-1
CORNER GUARD; CG
P-1
A500
A420
CEILING
ACCESS
PANEL
TILE WALL BASE; WB-1
EXISTING WALL MOUNTED ITEMS,
SIGNAGE, PHOTOS BOARDS ETC. TO
BE RE-INSTALLED BY CONTRACTOR.
SIGNAGE TO BE INSTALLED ON
STANDOFFS.
P-1
RESIN PANEL; RES-1
653 SF
CA153
YELLOW ENTRANCE
HALL
EXISTING MECHANICAL GRILLE
CORNER GUARD; CG
P-1
A500
P-1
A500
A420
TILE WALL BASE; WB-1
P-2
P-1
RESIN PANEL; RES-1
653 SF
CA153
YELLOW ENTRANCE
HALL
John R. Exit
CORNER GUARD; CG
DIMENSIONAL
METAL LETTERS
P-2
CORNER GUARD; CG
TILE WALL BASE; WB-1
SLIDING DOORREVOLVING DOOR
P-1
A500
A500
A420
EXISTING WALL MOUNTED ITEMS,
SIGNAGE, PHOTOS BOARDS ETC. TO BE RE-
INSTALLED BY CONTRACTOR
EXACT PLACEMENT AND SIZE TO BE VERIFIED
8' - 5"
TILE WALL BASE; WB-1
AFTER HOURS
CALL BOX
WITH SIGNAGE
P-1
RESIN PANEL; RES-1
P-1
118 SF
CA152
VESTIBULE
653 SF
CA153
YELLOW ENTRANCE
HALL
EXISTING ELECTRICAL PANELS
EXISTING
MECHANICAL
GRILLE
CORNER GUARD; CGP-1
CORNER GUARD; CG
A500
P-1
A500
A420
P-1
TILE WALL BASE; WB-1
P-2
AFTER HOUR
CALL BOX WITH
SIGNAGE
P-1
8' - 0"
RESIN PANEL; RES-1
152 SF
CB102
VESTIBULE
282 SF
CB103
RED ENTRANCE HALL
P-2
TILE WALL BASE; WB-1 RESIN PANEL; RES-1
CORNER GUARD; CG
P-1
A500
A500
A420
TILE WALL BASE; WB-1
P-1
P-2
RESIN PANEL; RES-1
P-1
282 SF
CB103
RED ENTRANCE HALL
A420
P-1
RESIN PANEL; RES-1
TILE WALL BASE; WB-1
EXISTING LETTERING
TO BE RE-INSTALLED
A500
A420
Hancock Exit
SIZE: 4"H DIMENSIONAL LETTERS
MATERIAL: ALUMINUM
FINISH: POWDER COAT
FONT: HELVETICA MEDIUM
INSTALL: USE MECHANICAL FASTENERS
John R. Exit
SIZE: 4"H DIMENSIONAL LETTERS
MATERIAL: ALUMINUM
FINISH: POWDER COAT
FONT: HELVETICA MEDIUM
INSTALL: USE MECHANICAL FASTENERS
PAINTED MDF; P-1
2' - 9 3/8" 4' - 0" 4' - 0" 2' - 9 3/8"
PANEL HEIGHT: FULL WALL HEIGHT
PANEL WIDTH: 4' MAX.
*AE TO PROVIDE CUSTOM
INTERLAYER IMAGE
" PRE-FABRICATED RESIN PANEL W/
HIGH-RESOLUTION IMAGE INTERLAYER,
SANDSTONE FINISH, MIRROR BACKING.
DIMENSIONS FOR THE RESIN PANEL ARE
PROVIDED WITHIN THE CUSTOM
INTERLAYER IMAGE.
VERTICAL PANEL JOINT; INSTALL
PANEL W/ TIGHT SEAM TO PREVENT GAP
PAINTED MDF; P-1
PANEL HEIGHT: FULL WALL HEIGHT
PANEL WIDTH: 4' MAX.
3' - 0"
*AE TO PROVIDE CUSTOM
NTERLAYER IMAGE
" PRE-FABRICATED RESIN PANEL W/
HIGH-RESOLUTION IMAGE INTERLAYER,
SANDSTONE FINISH, MIRROR BACKING.
DIMENSIONS FOR THE RESIN PANEL ARE
PROVIDED WITHIN THE CUSTOM
INTERLAYER IMAGE.
2' - 2 1/4" 4' - 0" 4' - 0" 2' - 2 1/4"
PAINTED MDF; P-1
PANEL HEIGHT: FULL WALL HEIGHT
PANEL WIDTH: 4' MAX.
2' - 3" 4' - 0" 4' - 0" 2' - 2 3/4"
*AE TO PROVIDE CUSTOM
INTERLAYER IMAGE
" PRE-FABRICATED RESIN PANEL W/
HIGH-RESOLUTION IMAGE INTERLAYER,
SANDSTONE FINISH, MIRROR BACKING.
DIMENSIONS FOR THE RESIN PANEL ARE
PROVIDED WITHIN THE CUSTOM
INTERLAYER IMAGE.
VERTICAL PANEL JOINT; INSTALL
PANEL W/ TIGHT SEAM TO PREVENT GAP
PAINTED MDF; P-1
PRE-FABRICATED RESIN PANEL W/
HIGH-RESOLUTION IMAGE INTERLAYER,
SANDSTONE FINISH, MIRROR BACKING.
DIMENSIONS FOR THE RESIN PANEL ARE
PROVIDED WITHIN THE CUSTOM
INTERLAYER IMAGE.
PANEL HEIGHT: FULL WALL HEIGHT
PANEL WIDTH: 4' MAX.
2' - 4 1/2" 4' - 0" 4' - 0" 2' - 4 1/2" 3' - 10 1/2" 3' - 10 1/2"
*AE TO PROVIDE CUSTOM
INTERLAYER IMAGE
VERTICAL PANEL JOINT; INSTALL
PANEL W/ TIGHT SEAM TO PREVENT GAP
PAINTED MDF; P-1
2' - 4 1/4" 4' - 0" 2' - 4 1/4"
PANEL HEIGHT: FULL WALL HEIGHT
PANEL WIDTH: 4' MAX.
*AE TO PROVIDE CUSTOM
INTERLAYER IMAGE
" PRE-FABRICATED RESIN PANEL W/
HIGH-RESOLUTION IMAGE INTERLAYER,
SANDSTONE FINISH, MIRROR BACKING.
DIMENSIONS FOR THE RESIN PANEL ARE
PROVIDED WITHIN THE CUSTOM
INTERLAYER IMAGE.
VERTICAL PANEL JOINT; INSTALL
PANEL W/ TIGHT SEAM TO PREVENT GAP
PAINTED MDF; P-1
3' - 3 5/8"
PANEL HEIGHT: FULL WALL HEIGHT
PANEL WIDTH: 4' MAX.
*AE TO PROVIDE CUSTOM
INTERLAYER IMAGE
" PRE-FABRICATED RESIN PANEL W/
HIGH-RESOLUTION IMAGE INTERLAYER,
SANDSTONE FINISH, MIRROR BACKING.
DIMENSIONS FOR THE RESIN PANEL ARE
PROVIDED WITHIN THE CUSTOM
INTERLAYER IMAGE.
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
INTERIOR ELEVATIONS REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK VG
100% CONSTRUCTION
DOCUMENTS
553-21-206
A420
SCALE: 1/4" = 1'-0"A420
RED ENTRANCE NORTH ELEVATION04
SCALE: 1/4" = 1'-0"A420
RED ENTRANCE WEST ELEVATION02
SCALE: 1/4" = 1'-0"A420
YELLOW ENTRANCE EAST INTERIOR ELEVATION06
SCALE: 1/4" = 1'-0"A420
YELLOW ENTRANCE SOUTH INTERIOR ELEVATION08
SCALE: 1/4" = 1'-0"A420
YELLOW ENTRANCE WEST INTERIOR ELEVATION05
SCALE: 1/4" = 1'-0"A420
RED ENTRANCE VESTIBULE EAST ELEVATION01
SCALE: 1/4" = 1'-0"A420
RED ENTRANCE NORTHWEST ELEVATION03
SCALE: 1/4" = 1'-0"A420
YELLOW ENTRANCE SOUTHEAST INTERIOR ELEVATION07
SCALE: 3" = 1'-0"A420
RED ENTRANCE EXIT SIGNAGE15
SCALE: 3" = 1'-0"A420
YELLOW ENTRANCE EXIT SIGNAGE16
SCALE: 1/4" = 1'-0"A420
3FORM PANEL - YELLOW ENTRANCE EAST10
SCALE: 1/4" = 1'-0"A420
3FORM PANEL - YELLOW ENTRANCE EAST - ANGLED09
SCALE: 1/4" = 1'-0"A420
3FORM PANEL - YELLOW ENTRANCE WEST11
SCALE: 1/4" = 1'-0"A420
3FORM PANEL -RED ENTRANCE EAST12
SCALE: 1/4" = 1'-0"A420
3FORM PANEL -RED ENTRANCE WEST14
SCALE: 1/4" = 1'-0"A420
3FORM PANEL -RED ENTRANCE WEST - ANGLED13
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
AUTOMATIC SLIDING DOOR
BY MANUFACTURER, REFER
TO DOOR SCHEDULE AND
TYPES
SLIDING DOOR GUIDE
TRACK
BREAKOUT DOOR PIVOT
POINT
BREAK METAL CONNECTION
TO SLIDING DOOR BY
MANUFACTURER
BREAK METAL CORNER
STOREFRONT WINDOW
SYSTEM, REFER TO
WINDOW TYPES
BREAK METAL WINDOW
MULLION CONNECTION,
BY MANUFACTURER
3-5/8" COLD FORM METAL
STUD
BLOCKING
AUTOMATIC REVOLVING
DOOR BY MANUFACTURER,
REFER TO DOOR SCHEDULE
CAULK/SEAL AT NEW WALL AND
REVOLVING STRUCTURE PER
MANUFACTURER
3/4" MDF BACKER
RES-1 1/4" RESIN DECORATIVE
WALL PANEL (REFER TO FIN.
SCH.)
NEW GYP. BOARD
CEILING ON EXISTING
METAL FRAMING
(1) LAYER OF 5/8" GYP. BOARD
BOTH SIDES ON 3-5/8" COLD
FORM METAL STUD ATTACHED
TO DECK ABOVE
COLD FORM METAL STUD BOX
HEADER
SEALANT AND BACKER ROD,
TYPICAL
AUTOMATIC SLIDING DOOR BY
MANUFACTURER, REFER TO
DOOR SCHEDULE
BOTTOM OF SLAB
METAL PANEL TO
MATCH STOREFRONT
SYSTEM
EXISTING MASONRY
2X P.T. BLOCKING
BATT INSULATION R-19
MIN.
SLIDING DOOR GUIDE TRACK
BREAKOUT DOOR PIVOT POINT
AUTOMATIC SLIDING DOOR
FRAME BY MANUFACTURER,
REFER TO DOOR SCHEDULE
AND TYPES
SLIDING DOOR AND
REVOLVING DOOR TO
INTERSECT AT REVOLVING
DOOR MULLION
1/4" SHIM AND SEALANT, TYP. AUTOMATIC REVOLVING
DOOR BY MANUFACTURER,
REFER TO DOOR SCHEDULE
(1) LAYER OF 5/8" GYP. BD. ON
7/8" STEEL HAT CHANNELS @
16" O.C. (MAX.) ATTACHED TO
EXISTING BRICK VENEER WALL
EXISTING BRICK VENEER WALL
1/4" SHIM AND
SEALANT, TYP.
BREAKOUT SLIDING
DOOR PER
MANUFACTURER
REQUIREMENTS
RES-1 1/4" RESIN DECORATIVE
WALL PANEL
3/4" MDF BACKER ON FRENCH
CLEAT ATTACHMENT
TILE BASE
DOOR THRESHOLD
(1) LAYER OF 5/8" GYP. BD.
EXISTING BRICK VENEER WALL
1/4" SHIM AND
SEALANT, TYP.
BREAKOUT SLIDING
DOOR PER
MANUFACTURER
REQUIREMENTS
TILE BASE
RES-1 1/4" RESIN DECORATIVE
WALL PANEL
3/4" MDF BACKER ON FRENCH
CLEAT ATTACHMENT
RES-1, 1/4" RESIN
DECORATIVE WALL PANEL
ADHERED TO MDF WITH
ADHESIVE
R E F E R
T O
E
LE
V A
TI
O
N S F
O R
H
IG
H T
A .F
.F
FRENCH CLEAT WALL PANEL
ATTACHMENT FASTENED TO
7/8" HAT CHANNEL ON
EXISTING WALL
DADO JOINT MILLED INTO
RESIN WHERE IT MEETS
THE MDF
3/4" MDF BACKER, PAINTED;
REFER TO INTERIOR ELEVATIONS
MDF MILLED WITH VOID
WHERE RESIN INLAYS
RECESSED LIGHT FIXTURE;
REFER TO ELECTRICAL
LIGHTING PLAN FOR
FURTHER INFORMATION
METAL STUD
FRAMING AS REQ'D.
5/8" GYP. BD. ON 3-5/8"
METAL STUDS
METAL CORNER BEAD,
TYP.
TRANSOM WINDOW
REVOLVING DOOR
EXISTING
STRUCTURE
EXTERIOR
SPANDREL PANEL
STEEL ANGLE; SUPPORT
AS NEEDED.
BATT INSULATION -
R19 MIN.
NEW 5/8" GYP. BOARD
CEILING ON EXISTING
METAL FRAMING
NEW 5/8" GYP. BOARD
ON METAL STUDS, 16"
O.C.
TRANSOM WINDOW WITH 1"
INSULATED GLASS UNIT INSIDE
LITE TO BE LAMINATED GLASS.
UNIT TO HAVE 1/2" MIN.
MULLION SETTING. APPLY
CONTINUOUS BEAD OF
STRUCTURAL SILICONE ADHESIVE
TO ATTACH THE INNER LITE TO
THE FRAME.
EXISTING STRUCTURE
WITH BRICK VENEER
1/4" SHIM AND SEALANT, TYP.
AUTOMATIC SLIDING DOOR BY
MANUFACTURER, REFER TO
DOOR SCHEDULE AND TYPES
4 7/8"
STEEL ANGLE; SUPPORT
AS NEEDED.
DADO JOINT MILLED INTO
RESIN WHERE IT MEETS THE
MDF
3/4" MDF BACKER, PAINTED;
REFER TO INTERIOR ELEVATIONS
FRENCH CLEAT WALL PANEL
ATTACHMENT FASTENED TO
7/8" HAT CHANNEL ON
EXISTING WALL
FRENCH CLEAT ATTACHMENT
TILE WALL BASE
A500
A500
RES-1, 1/4" RESIN
DECORATIVE WALL PANEL
ADHERED TO MDF WITH
ADHESIVE
MDF MILLED WITH VOID
WHERE RESIN INLAYS
SUBSTRATE. PREP PER
MANUF.
RECOMMENDATIONS
METAL COVE
TRANSITION STRIP
(MTS-1), SEE FINISH
SCHEDULE AND KEY
CERAMIC TILE INSTALL
TOP FLUSH WITH METAL
TRANSITION STRIP,
REFER TO FINISH
SCHEDULE AND KEY
TILE THIN SET MORTAR,
SEE SPECIFICATION
METAL TRANSITION
STRIP AT TOP OF WALL
BASE (MTS-2), SEE
FINISH SCHEDULE AND
KEY
FRENCH CLEAT WALL PANEL
ATTACHMENT FASTENED TO 7/8"
HAT CHANNEL ON EXISTING WALL
RES-1 1/4" RESIN DECORATIVE
WALL PANEL (REFER TO FIN. SCH.)
3/4" MDF BACKER
CAULK/SEAL JOINT AT TRANSITION
SUBSTRATE. PREP PER
MANUF.
RECOMMENDATIONS
METAL COVE
TRANSITION STRIP
(MTS-1), SEE FINISH
SCHEDULE AND KEY
CERAMIC TILE INSTALL
TOP FLUSH WITH METAL
TRANSITION STRIP,
REFER TO FINISH
SCHEDULE AND KEY
TILE THIN SET MORTAR,
SEE SPECIFICATION
METAL TRANSITION
STRIP AT TOP OF WALL
BASE (MTS-2), SEE
FINISH SCHEDULE AND
KEY
EXISTING WALL
CONSTRUCTION
EXPANSION JOINT
(MTS-3), REFER TO
FINISH KEY &
SCHEDULE
CERAMIC TILE INSTALL
FLUSH W/ EXPANSION
JOINT; REFER TO FINISH
KEY & SCHEDULE
TILE THIN SET MORTAR; SEE
SPECIFICSTION
SUBSTRATE PREP PER
MANUF.
RECOMMENDATIONS
RES-1 1/4" RESIN DECORATIVE
WALL PANEL ON 7/8" STEEL
HAT CHANNELS @ 16" O.C.
(MAX.) ATTACHED TO
EXISTING BRICK VENEER WALL
(1) LAYER OF 5/8" GYP. BD.
ATTACHED TO EXISTING BRICK
VENEER WALL
CORNER GUARD
EXISTING BRICK WALL
EXISTING GYP. FINISH
TILE BASE
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
DETAILS REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
A500
SCALE: 1 1/2" = 1'-0"A500
DOOR JAMB DETAIL07
SCALE: 1 1/2" = 1'-0"A500
PLAN DETAIL08
SCALE: 1 1/2" = 1'-0"A500
DOOR HEAD DETAIL05
SCALE: 1 1/2" = 1'-0"A500
PLAN DETAIL10
SCALE: 1 1/2" = 1'-0"A500
DOOR JAMB DETAIL03
SCALE: 1 1/2" = 1'-0"A500
DOOR JAMB DETAIL02
SCALE: 1 1/2" = 1'-0"A500
DOOR JAMB DETAIL01
SCALE: 12" = 1'-0"A500
WALL PROTECTION TOP EDGE11
SCALE: 1 1/2" = 1'-0"A500
SOFFIT DETAIL13
SCALE: 1 1/2" = 1'-0"A500
DOOR HEAD DETAIL06
SCALE: 1 1/2" = 1'-0"A500
WALL PROTECTION SECTION09
SCALE: 12" = 1'-0"A500
TILE COVE BASE DETAIL12
SCALE: 12" = 1'-0"A500
TILE COVE BASE14
SCALE: 12" = 1'-0"A500
EXPANSION JOINT15
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
100% Construction Documents - Resubmission 11/15/21
SCALE: 1 1/2" = 1'-0"A500
PLAN DETAIL04
S
E S
C H
E D
U
LE
SEE SCHEDULE SEE SCHEDULE
S E E S
C H
E D
U
LE
EXISTING EXTERIOR
CONCRETE FLOOR
TO REMAIN
EXISTING RECESSED
FLOOR SLAB
INFILL CONCRETE/
SETTING BED
NEW TILE FLOORING
NEW SLIDING DOOR
SYSTEM
1/2" THERMAL BREAK
MATERIAL @ INFILL
INTERIOR
EXTERIOR
EXISTING RECESSED
FLOOR SLAB
NEW TILE FLOORING
INFILL CONCRETE/
SETTING BED
1/2" THERMAL BREAK
MATERIAL @ INFILL
EXISTING EXTERIOR CONCRETE
TO REMAIN
REVOLVING DOOR THRESHOLD
INTERIOR EXTERIOR
LAMINATED
GLAZING UNIT
2' - 5"
SPANDREL
PANEL
LAMINATED
GLAZING UNIT
SPANDREL
PANEL
LAMINATED
GLAZING UNIT
19' - 11 1/2"
3" 7' - 7 1/2" 3" 5' - 8 3/4" 3" 5' - 7 1/4" 3"
3"
9' - 7 1/8" 3"
4' - 1 1/2" 2" 4' - 2" 2" 4' - 1 7/8"
3"
23' - 1 5/8"
FLOOR LINE
1 2 3
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
DOOR AND FRAME
SCHEDULE
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK GN
100% CONSTRUCTION
DOCUMENTS
553-21-206
A600
DOOR AND FRAME SCHEDULE OPTION 1
DOOR
NUMBER ROOM NAME SIZE
DOOR FRAME FIRE RATING
(MIN.) HARDWARE SET REMARKSTYPE MATERIAL TYPE MATERIAL
102A CA102 - RED ENTRANCE VESTIBULE 10'-0" W x 8'-4" H A ALUM/GLASS ALUM SLIDING DOOR UNIT WITH LAMINATED GLAZING UNITS
102B CA102 - RED ENTRANCE VESTIBULE 10'-0" W x 8'-4" H A ALUM/GLASS ALUM SLIDING DOOR UNIT WITH LAMINATED GLAZING UNITS
103 CA103 - RED ENTRANCE HALL 14'-0" DIA. x 8'-4" H B ALUM/GLASS 3 ALUM - FLOOR MOUNTED REVOLVING DOOR UNIT WITH INTEGRAL MOUNTING BRACKETS AND LAMINATED GLAZING
UNITS. WALL GLASS TO BE TINTED AND DOOR GLASS TO BE CLEAR
152A CA152 - YELLOW ENTRANCE
VESTIBULE
8' 0" W x 8' - 4" H A ALUM/GLASS ALUM SLIDING DOOR UNIT WITH LAMINATED GLAZING UNITS
152B CA152 - YELLOW ENTRANCE
VESTIBULE
8' 0" W x 8' - 4" H A ALUM/GLASS ALUM SLIDING DOOR UNIT WITH LAMINATED GLAZING UNITS
153 CA153 - YELLOW ENTRANCE HALL 14'-0" DIA. x 8'-4" H B ALUM/GLASS 2 ALUM - FLOOR MOUNTED REVOLVING DOOR UNIT WITH INTEGRAL MOUNTING BRACKETS AND LAMINATED GLAZING
UNITS. WALL GLASS TO BE TINTED AND DOOR GLASS TO BE CLEAR
DOOR TYPES
FLOOR LINE
FRAME TYPES
A B
SCALE: 1 1/2" = 1'-0"A600
DOOR SILL/FLOOR DETAIL01
SCALE: 1 1/2" = 1'-0"A600
DOOR SILL/FLOOR DETAIL02
Revisions: Date:
35% Schematic Design 5/26/20
65% Design Development 10/02/20
95% Construction Documents 12/04/20
100% Construction Documents 03/24/21
A42004
A420
1' - 2"
282 SF
CB103
RED ENTRANCE HALL
CB102
VESTIBULE
22' - 0 5/8" 6" 4' - 0" 6"
AD101 3
INSTALL NEW TILE TO LAY FLUSH
W/ EXISTING TILE
ALIGN TILE PATTERN
TO WALLALIGN TILE PATTERN
TO WALL
ALIGN TILE PATTERN
TO WALL
ALIGN TILE PATTERN
TO WALL
SURFACE MOVEMENT JOINT
BETWEEN NEW AND EXISTING TILE
SURFACE MOVEMENT JOINT
8' - 0" 5' - 0"
SURFACE MOVEMENT JOINT;
ALIGN TO NATURAL TILE BREAKS
/4
A500
A500
EMERGENCY AFTER-HOURS
CALL BOX
CA152
VESTIBULE
A420
653 SF
CA153
YELLOW ENTRANCE
HALL
A420
/4
AD101
ALIGN TILE PATTERN
TO WALL
ALIGN TILE PATTERN
TO WALL
ALLIGN TILE PATTERN
TO WALL
ALIGN TILE PATTERN
TO WALL
SURFACE
MOVEMENT JOINT;
ALIGH TO NATURAL
TILE BREAKS
INSTALL NEW TILE TO
LAY FLUSH W/ EXISTING TILE
/4
/4
SURFACE
MOVEMENT JOINT
SURFACE
MOVEMENT JOINT
14' - 7 5/8"
A500
A500
FINISH PLAN LEGEND
PORC-1
PORC-2
RANDOM MIX OF
PORC-1, PORC-3, PORC-4
OUTSIDE OF SCOPE
DEDUCT ALTERNATES
REFER TO SECTION 01 00 00 - GENERAL REQUIREMENTS FOR
MORE INFORMATION
A101 DEDUCTIVE ALTERNATIVE NO. 1 - DELETE RESIN
WALL PANELS
A700 DEDUCTIVE ALTERNATIVE NO. 2 - DELETE
EXPANDED AREA OF FLOOR TILE
A121 DEDUCTIVE ALTERNATIVE NO. 3 - DELETE
REMOVING COMPLETE YELLOW ENTRANCE
CEILING
A121 DEDUCTIVE ALTERNATIVE NO. 4 - DELETE AIR
CURTAIN FROM REVOLVING DOOR
INTERIOR FINISH KEY - GENERAL NOTES
THE MANUFACTURER PRODUCT IDENTIFIED MEETS THE SALIENT CHARACTERISTICS OF THIS SPECIFICATION.
SUCH INFORMATION IS ONLY TO SHOW AN EXAMPLE OF PRODUCTS WHICH MEET THE SPECIFIACTION AND
DO NOT, IN ANY WAY, LIMIT THE OFFERER FROM PROVIDING PRODUCTS FROM OTHER MANUFACTURERS
WHICH MEET THE SALIENT CHARACTERISTICS AS IDENTIFIED IN THE SPECIFIACTION.
ENERGY
CENTER
NORTH
PARKING
DECK
SOUTH
PARKING
DECK
4 3
8 7
2 1
Building Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
JOHN
D. DINGELL
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
7GAE PROJECT NO.: 220010
Project Number
Drawing Number
DWG. ___ OF 23
Sprinkler:
INTERIOR FINISH KEY & FINISH
PLANS
REPLACE YELLOW
AND RED ENTRANCES
4646 JOHN R. STREET
DETROIT, MICHIGAN 48201
PROJECT DIRECTOR
February 11, 2022 BK VG
100% CONSTRUCTION
DOCUMENTS
553-21-206
A700
NORTH
SCALE: 1/4" = 1'-0"
FIRST FLOOR
RED ENTRANCE
NORTH
SCALE: 1/4" = 1'-0"
FIRST FLOOR
YELLOW
ENTRANCE
INTERIOR FINISH KEY
TAG MATERIAL MANUFACTURER STYLE COLOR REMARKS
01 FLOORING
GR-1 GROUT TEC POWER GROUT RAVEN
PORC-1 PORCELAIN TILE CROSSVILLE STRUCTURE AV221 GYPSUM 6"x24" UNPOLISHED
PORC-2 PORCELAIN TILE IRIS DELUXE OCEAN STORM 6"X24" HONED
PORC-3 PORCELAIN TILE CROSSVILLE STRUCTURE AV221 GYPSUM 12"X24" UNPOLISHED
PORC-4 PORCELAIN TILE CROSSVILLE STRUCTURE AV223 SHALE 6"X24" UNPOLISHED
02 WALL BASE
PORC-1W PORCELAIN TILE WALL
BASE
IRIS DELUXE OCEAN STORM COVE BASE, HONED, 6"X12"
03 WALL FINISH
P-1 INTERIOR PAINT PITTSBURGH PAINT (PPG) INTERIOR LATEX,
EGGSHELL
MATCH SHERWIN WILLAIMS - SW7551 GREEK
VILLA
FIELD COLOR
RES-1 RESIN PANELS 3FORM VARIA HIGH RESOLUTION…