551-22184.CAK - MSP-Ionia EB Scale New Building - Drwg File 0006.pdf
PDF 6 MB Posted
- Solicitation number
- RFQ - 171 - 230000000797
- Issued by
- Ionia County, Michigan
About this file
This document is an electrical lighting plan for the MSP-Ionia EB Scale New Building project. The project is located in Ionia County, Michigan and is being managed by the Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division.
The scope of work involves the electrical design for the new weigh station building, including the layout and specifications for lighting fixtures, wall switches, and emergency egress lighting. The plan provides lighting levels and statistics for various rooms and areas within the building. Bidders are instructed to submit their proposals through the SIGMA VSS online system, with attachments limited to 6 MB in size. Questions should be emailed to the designated project manager, and bidders experiencing SIGMA VSS issues may be allowed to submit their proposals via email, subject to approval by the Design and Construction Division.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RA-EM
RARA
RARA-EM
RA
RA-EM
CA
CA
CA
CA
CA
CA CA
BB
BA-EM
XA
XA
BA-EM
WD
WD
PC
C
CACA
CA
LRP-4
CACA
CA
B
WSP
D-42
PRIMARY DAYLIGHT ZONE
SECONDARY DAYLIGHT ZONE
WS6
WS6
F
E
E
E2.1
E2.1
LRP-8
LRP-8
RA-EM
RA
RA
RA-EM
C
D-42
RA
RA RA
WD
RA-EM RA RA RA-EM
V D-42
RB
RB
RA
RA
WS
RA RA
WS
RA RA
WD
IA
EM
IA
EM
IA
EM
IB
IB
UA
UA
UA
XAXA
IB
IB
CA
WSP
D-42
C
C
C
WD WD
A
A
C
DC
WD
WD
E2.1
G
G
C
D
G
G
TYP
A
D-38 D-38
D-38
DC
PP
PP
D-38
D-38
D-38 D-42
D-42
D-42
D-42
WSP
WSP
DC
DC
PP
PP
D-42
D-42
D-38
RA
10'-0" AFF
RA
10'-0" AFF
RA
10'-0" AFF
RA
10'-0" AFF
RA-EM
10'-0" AFF
RA-EM
10'-0" AFF
D-40 D-40D-40
D-40
WSK
ELECTRICAL LIGHTING PLAN
SCALE: 1/4" = 1'-0"
N
KEY PLAN NOTES
1. WALL MOUNTED BELOW WINDOW 16" ABOVE FINISHED GRADE FOR TRUCK
INSPECTION. WIRE TO LIGHTING RELAY PANEL AND PROGRAM FOR MANUAL
ON/OFF OPERATION VIA MOMENTARY SWITCH WALL STATIONS, "WS6".
2. COORDINATE FIXTURE MOUNTING WITH OTHER DISCIPLINES SUSPENDED AT
OR BELOW PIPING AND DUCTWORK.
3. PROVIDE WIRELESS SWITCH PACK FOR SENSORED CONTROL OF EXHAUST
FAN IN SAME SPACE.
WALL SWITCH ELEVATION1
NOT TO SCALEE2.1
WALL SWITCH ELEVATION2
NOT TO SCALEE2.1
RAISE
LOWER
ON/OFF
COOPER #W3L-* (OR EQUIVALENT)
*FINISH SELECTED BY ARCHITECT
**VERIFY BUTTON ENGRAVINGS WITH OWNER
WD=
LANE
COOPER #GDS-6TSB-W-* (OR EQUIVALENT)
*FINISH SELECTED BY ARCHITECT
**VERIFY BUTTON ENGRAVINGS WITH OWNER
WS6
SCALE
PARKING
OVERHEAD
ALL ON/OFF
EXTERIOR LIGHT CONTROLS
BD
L
D
AM
GENERAL NOTES
A. WIRE ALL EMERGENCY EGRESS LIGHTING TO THE UNSWITCHED LEG OF THE
LOCAL LIGHTING CIRCUIT.
C op yr ig ht
3, S ch le y N el so n A rc hi te ct s, In c.
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph o ne (6
) 3
.9 co m p e ng
.co m
CE
: 2
P la in fie ld
A ve nu e
N E, S ui te A
G ra nd R a p id s, M I 4
D e sig ne d
B y:
D ra w n
By
E2.1
LRP-2
LRP-4
LRP-3
LRP-7,8
1.0
2.1
2.5
2.9
3.4
2.7
5.2
6.1
5.6
2.7
3.2
3.7
4.3
5.1
6.2
6.1
3.4
4.0
4.6
5.1
5.8
6.5
6.3
6.0
4.1
4.9
5.4
5.6
4.4
5.0
5.7
5.5
4.6
5.5
5.4
4.0
1.2
4.2
4.7
4.5
4.5
5.0
4.9
4.1
3.0
3.5
3.8
3.6
0.7
6.8
4.7
5.3
5.5
5.2
5.2
6.1
6.4
6.0
5.1
5.4
6.4
6.3
5.3
5.2
6.1
6.4
6.0
5.1
4.7
5.3
5.5
5.3
4.6 4.6
6.8
6.5
6.5
7.0
6.9
6.9
6.8
6.1
6.1
5.0
5.0
4.1
4.1
3.5
3.5
3.6
3.6
4.2
4.2
5.2
5.2
6.4
6.3 7.0
3.2
3.2
3.2
3.2
7.1
7.1
7.1
5.2
5.3
4.8
3.9
3.1
2.5
2.2
2.0
1.9
1.8
5.8
5.9
5.3
4.3
3.4
2.8
2.5
2.4
2.3
2.2
2.1
5.7
5.9
5.3
4.3
3.5
3.0
2.8
2.8
2.8
2.8
2.6
5.0
5.2
4.7
4.0
3.4
3.1
3.1
3.4
3.6
3.6
3.4
4.0
4.1
3.9
3.5
3.2
3.2
3.5
4.0
4.5
4.7
4.5
3.1
3.2
3.1
3.0
3.0
3.2
3.8
4.6
5.4
5.7
5.4
2.4
2.5
2.6
2.6
2.7
3.1
3.8
4.8
5.8
5.9
2.0
2.1
2.2
2.3
2.5
2.9
3.6
4.6
5.5
5.9
5.6
1.8
1.9
2.0
2.3
2.6
3.2
3.9
4.6
4.9
4.71.7
1.7
6.2
5.1
4.8
4.8
5.2
6.0
6.0
5.3
4.8
4.8
5.1
5.9
6.1
5.7
5.1
4.9
5.1
5.7
6.2
6.3
5.8
5.2
5.0
5.2
5.7
6.2
6.0
6.2
6.3
5.8
5.1
4.7
4.7
5.0
5.3
5.3
5.1
4.8
4.8
5.2
5.9
6.5
6.3
5.7
5.9
5.4
4.7
4.2
4.1
4.2
4.3
4.3
4.2
4.2
4.4
4.9
5.7
6.2
5.9
4.9
5.0
4.6
4.0
3.6
3.3
2.9
6.6
6.6
4.5
4.9
4.9
5.5
6.2
6.2
5.4
6.1
6.1
6.1
6.1
5.4
6.2
6.2
5.4
4.9
4.9
4.4
4.4
4.4
7.1
7.1
7.1
7.1
5.5
6.2
6.3
5.8
5.9
6.7
6.1
5.6
6.3
6.4
5.8
4.8
5.4
5.4
5.0
4.3
4.4
4.1
4.0
6.8
3.1
3.3
3.2
2.9
3.2
3.8
3.9
3.4
2.8
3.2
3.4
3.3
3.0
2.7
4.0
3.4
3.9
4.2
4.2
3.8
4.1
4.9
5.3
5.2
4.6
4.2
4.9
5.3
5.2
4.7
4.2
4.9
5.2
4.7
3.9
4.6
5.0
4.9
4.4
3.6
3.9
3.9
3.6
3.2
5.4
0.6
0.6
0.6
0.6
0.7 0.7
0.7
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.8
0.8
0.8
0.8
Statistics
Description Symbol Avg Max Min Max/Min Avg/Min
BACK ENTRY (MEETING RM) 0.7 fc 0.8 fc 0.6 fc 1.3:1 1.2:1 ELEC/ DATA EM 107 3.3 fc 4.0 fc 2.7 fc 1.5:1 1.2:1 Fitness/ BREAK/ MEETING ROOM 110A 3.6 fc 6.2 fc 1.7 fc 3.6:1 2.1:1
HALL 105 5.3 fc 7.1 fc 3.2 fc 2.2:1 1.7:1 LOBBY 101 4.4 fc 6.8 fc 0.7 fc 9.7:1 6.3:1 MAIN ENTRY 0.6 fc 0.7 fc 0.6 fc 1.2:1 1.0:1 MECH. ROOM 109 4.4 fc 5.4 fc 3.2 fc 1.7:1 1.4:1 MSP CTL ROOM 102A 5.2 fc 6.6 fc 2.9 fc 2.3:1 1.8:1 MSP OFFICE 104 5.5 fc 6.8 fc 4.6 fc 1.5:1 1.2:1 MULTI-USE 108 5.5 fc 6.8 fc 4.0 fc 1.7:1 1.4:1 STAFF LOCKERS 106A 5.7 fc 7.1 fc 4.4 fc 1.6:1 1.3:1
EMERGENCY EGRESS LIGHTING LEVELS
SCALE: 1/4" = 1'-0"
N
BD
L
D
AM
C op yr ig ht
3, S ch le y N el so n A rc hi te ct s, In c.
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph o ne (6
) 3
.9 co m p e ng
.co m
CE
: 2
P la in fie ld
A ve nu e
N E, S ui te A
G ra nd R a p id s, M I 4
D e sig ne d
B y:
D ra w n
By
E9.1
| 81-E1.0 |
| 81-E1.1 |
| 84-E2.1 |
| 84-E2.1 |
| 85-E3.1 |
| 89-E6.1 |
| 90-E9.1 |
| 90-E9.1 |
File details come from the government source that posted it. Updated .