This document provides details for a federal solicitation seeking bids to upgrade fire protection and emergency notification systems. The solicitation number is 36C25223B0022 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 for project 550-22-102-CON. Interested vendors are invited to submit bids by the response date to provide drawings, installation, maintenance, and related services to improve fire safety equipment and emergency alerts at a VA medical center. The solicitation includes a 19MB PDF file with project drawings and specifications. Bids are due by the date listed to be considered for an award to be made thereafter to upgrade critical life safety systems for veterans receiving care at this VA facility.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AR
CH
T em pla te_
R1 9_ de tac he d.r vt 4/4
/20
3:
:54 P
M
58 & 98
DANVILLE VA MEDICAL CENTER
1900 E MAIN ST, DANVILLE, IL 61832
VAMC PROJECT #: 550-22-102
UPGRADE FIRE PROTECTION AND EMERGENCY NOTIFICATION
SHEET INDEXPROJECT SUMMARYAERIAL IMAGE
MR ZAM
00-GI001
COVER
1"
5' 3/3
2"
1' 1/1
6"
1' 1/3
2"
1' 1"
1"
1"
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
100% CONSTRUCTION
DOCUMENTS
12/14/2022
Sheet # Sheet Title
00-GI001 COVER
00-GI002 GENERAL INFORMATION AND ABBREVIATIONS
00-GI110 ICRA DIAGRAMS - BUILDING 58
00-GI111 ICRA DIAGRAMS - BUILDING 58
00-GI112 ICRA DIAGRAMS - BUILDING 98
00-GI113 ICRA DIAGRAMS - BUILDING 98
00-FA001 FIRE ALARM GENERAL NOTES AND LEGEND
00-FA002 FIRE ALARM SEQUENCE OF OPERATIONS
00-FA003 FIRE ALARM RISER DIAGRAMS
58-FD101 B58 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREA A
58-FD102 B58 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREAS B & C
58-FD103 B58 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREA A
58-FD104 B58 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREAS B & C
58-FD105 B58 - SECOND FLOOR FIRE ALARM DEMOLITION PLAN - AREA A
58-FD106 B58 - SECOND FLOOR FIRE ALARM DEMOLITION PLAN - AREAS B & C
58-FD107 B58 - THIRD FLOOR FIRE ALARM DEMOLITION PLAN - AREA A
58-FD108 B58 - THIRD FLOOR FIRE ALARM DEMOLITION PLAN - AREAS B & C
58-FD109 B58 - FOURTH FLOOR FIRE ALARM DEMOLITION PLAN - AREAS A & B
58-FD110 B58 - FIFTH FLOOR FIRE ALARM DEMOLITION PLAN - AREAS A & B
58-FD111 B58 - ATTIC FIRE ALARM DEMOLITION PLAN - AREAS A & B
98-FD101 B98 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREA A
98-FD102 B98 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREA B
98-FD103 B98 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREA A
98-FD104 B98 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREA B
98-FD105 B98 - SECOND FLOOR FIRE ALARM DEMOLITION PLAN - AREA A
98-FD106 B98 - SECOND FLOOR FIRE ALARM DEMOLITION PLAN - AREA B
98-FD107 B98 - THIRD FLOOR FIRE ALARM DEMOLITION PLAN - AREA A
98-FD108 B98 - THIRD FLOOR FIRE ALARM DEMOLITION PLAN - AREA B
98-FD109 B98 - ATTIC FIRE ALARM DEMOLITION PLAN
58-FA101 B58 - BASEMENT FIRE ALARM NEW WORK PLAN - AREA A
58-FA102 B58 - BASEMENT FIRE ALARM NEW WORK PLAN - AREAS B & C
58-FA103 B58 - FIRST FLOOR FIRE ALARM NEW WORK PLAN - AREA A
58-FA104 B58 - FIRST FLOOR FIRE ALARM NEW WORK PLAN - AREAS B & C
58-FA105 B58 - SECOND FLOOR FIRE ALARM NEW WORK PLAN - AREA A
58-FA106 B58 - SECOND FLOOR FIRE ALARM NEW WORK PLAN - AREAS B & C
58-FA107 B58 - THIRD FLOOR FIRE ALARM NEW WORK PLAN - AREA A
58-FA108 B58 - THIRD FLOOR FIRE ALARM NEW WORK PLAN - AREAS B & C
58-FA109 B58 - FOURTH FLOOR FIRE ALARM NEW WORK PLAN - AREAS A & B
58-FA110 B58 - FIFTH FLOOR FIRE ALARM NEW WORK PLAN - AREAS A & B
58-FA111 B58 - ATTIC FIRE ALARM NEW WORK PLAN - AREAS A & B
98-FA101 B98 - BASEMENT FIRE ALARM NEW WORK PLAN - AREA A
98-FA102 B98 - BASEMENT FIRE ALARM NEW WORK PLAN - AREA B
98-FA103 B98 - FIRST FLOOR FIRE ALARM NEW WORK PLAN - AREA A
98-FA104 B98 - FIRST FLOOR FIRE ALARM NEW WORK PLAN - AREA B
98-FA105 B98 - SECOND FLOOR FIRE ALARM NEW WORK PLAN - AREA A
98-FA106 B98 - SECOND FLOOR FIRE ALARM NEW WORK PLAN - AREA B
98-FA107 B98 - THIRD FLOOR FIRE ALARM NEW WORK PLAN - AREA A
98-FA108 B98 - THIRD FLOOR FIRE ALARM NEW WORK PLAN - AREA B
98-FA109 B98 - ATTIC FIRE ALARM NEW WORK PLAN
00-E-001 ELECTRICAL NOTES
00-E-002 ELECTRICAL PLAN - FIRE ALARM RISER CIRCUITING
58-E-101 B58 - BASEMENT ELECTRICAL PLAN - AREA A
58-E-102 B58 - FIRST FLOOR ELECTRICAL PLAN - AREA A
98-E-101 B98 - BASEMENT ELECTRICAL PLAN - AREA B
98-E-102 B98 - FIRST FLOOR ELECTRICAL PLAN - AREA A
MRohall Snapshot
MRohall Snapshot
ZMiller Image
A. CONTRACTORS AND THEIR SUPERVISORY PERSONNEL SHALL REVIEW THE GENERAL AND
SUPPLEMENTARY CONDITIONS TO THE CONTRACT.
B. WORK SHALL CONFORM WITH PROJECT SPECIFICATIONS.
C. CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK.
QUESTIONS WILL BE DIRECTED TO VHA COR.
D. CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND THE SAFETY OF CONSTRUCTION PERSONNEL AND VISITORS.
E. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF
THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE
CONTRACTOR. REFER TO SPECIFICATION SECTION 01 33 23.
F. EACH CONTRACTOR AND SUBCONTRACTOR WILL EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE CONTRACTOR, IN WRITING, CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THEIR WORK. DO NOT PROCEED UNTIL
UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH INSTALLATION WILL
CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.
G. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT VHA COR FOR
CLARIFICATIONS, IF REQUIRED.
H. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR DIMENSION IS
REPRESENTATIVE OF, OR THE SAME, FOR SIMILAR CONDITIONS THROUGHOUT.
I. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN, SECTION, & DETAIL DRAWINGS, ETC), CONTACT VHA COR FOR CLARIFICATION.
J. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, SPECIFICATIONS
GOVERN. CONTACT VHA COR FOR CLARIFICATION.
K. DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS SHALL BE REPORTED TO THE
VHA COR, IN WRITING, FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
L. DISCREPANCIES SHALL BE REPORTED TO THE VHA COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR
ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE CONTRACTING OFFICER'S WRITTEN
DIRECTION AND APPROVAL. ALSO, CONTRACTOR SHALL REPAIR AND/OR REPLACE UNAUTHORIZED
WORK, AS INDICATED BY THE VHA COR, AT NO ADDITIONAL COST TO THE VHA.
M. DISSIMILAR METAL MATERIALS SHALL BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION
MATERIAL IN ACCORDANCE WITH SPECIFICATIONS.
N. EXTERIOR EXPOSED STEEL SHALL BE PAINTED PER SPECIFICATION SECTION 09 91 00.
O. CONTRACTOR SHALL VERIFY THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES AND THEIR SERVICE CONNECTIONS WITH THE PROPER UTILITY COMPANY, COORDINATE ISSUES WITH VHA COR.
P. CONTRACTOR SHALL COORDINATE SIZE, LOCATIONS AND NUMBER OF ROOF OPENINGS AND ROOF
ACCESSORIES WITH OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING,
MECHANICAL AND ELECTRICAL DRAWINGS FOR REFERENCE AND SPECIFICATIONS FOR
REQUIREMENTS.
Q. LOCATIONS AND SIZES OF CONCRETE MECHANICAL AND ELECTRICAL EQUIPMENT PADS SHALL BE
COORDINATED BY THE MECHANICAL AND ELECTRICAL CONTRACTORS WITH THE SELECTED
EQUIPMENT MANUFACTURER AND/OR SUPPLIER. LOCATIONS ARE TO BE APPROVED BY THE VHA COR
PRIOR TO PROCEEDING WITH THE WORK.
R. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
S. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD AS REQUIRED FOR THE MOUNTING OF
TOILET ACCESSORIES, MILLWORK, CASEWORK, AV EQUIPMENT, MEP ITEMS AND RADIOLOGY
EQUIPMENT, ETC. REFER TO SPECIFICATIONS.
T. PROPRIETARY PRODUCTS IN THE DRAWINGS SHALL MEET SPECIFICATION REQUIREMENTS.
A
ROOM NAME
P2
RB3
C
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
DETAIL CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION, DETAIL, OR ELEVATION
SYMBOL IDENTIFIERS
DETAIL NAME
LETTER OR NUMBER DESIGNATOR
DRAWING SEQUENCE NUMBER
INDICATES WHERE TITLE IS LOCATED
ONE OR TWO CHARACTER
DISCIPLINE DESIGNATOR (MAY
NOT BE PRESENT IF CALLOUT
AND TITLE ARE ON DRAWINGS
WITHIN THE SAME DISCIPLINE)
AE101
DOOR NUMBER TAG
WALL TYPE TAG
WINDOW TYPE TAG
CENTER LINE
WALL FINISH TAG
COLUMN BUBBLE
ROOM TAG
WALL COLOR
BASE TYPE / COLOR
MATCH LINE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
DETAIL NUMBER ON SHEET
SHEET NUMBER
NEW LINE TYPE
EXISTING LINE TYPE
DEMO LINE TYPE
DEMO HATCH TYPE
1 View Name 1/8" = 1'-0"
AE101
AE101
A A101
FLOOR PLAN SYMBOLS LEGEND
EARTH / COMPACT FILL
GRAVEL / GRANULAR FILL
CONCRETE
SAND/ MORTAR/
PLASTER/ CUT STONE
BRICK
CONCRETE MASONRY UNIT
STONE (ELEVATION)
BATT INSULATION
ROOF INSULATION
RIGID INSULATION
ACOUSTICAL TILE (SECTION)
GYPSUM BOARD
COVER BOARD
STEEL / METAL
FINISH WOOD
CONT WOOD BLOCKING /
ROUGH FRAMING
CAST STONE
DISCONTINUOUS
WOOD BLOCKING /
SHIM
PLYWOOD
MASONRY INSULATION
FIREPROOFING
EIFS (SECTION)
METAL / WALL PANELS
SPANDREL
GLASS
MATERIALS LEGEND
1 HOUR FIRE NEW
2 HOUR FIRE NEW
1 HOUR FIRE EXISTING
2 HOUR FIRE EXISTING
0 HOUR SMOKE PARTITION NEW
0.5 HOUR SMOKE NEW
1 HOUR FIRE/SMOKE NEW
2 HOUR FIRE/SMOKE NEW
SMOKE EXISTING
0.5 HOUR SMOKE EXISTING
1 HOUR FIRE/SMOKE EXISTING
2 HOUR FIRE/SMOKE EXISTING
C:
\U se rs\
VA
A rch ite ct
\D oc um en ts\ Re vit
\19
.25 _A
RC
H_
R2 2_ zm ille r4
NR
TZ
.rv t 4/1
3/2
2 7 :06
:51 A
M
GENERAL NOTESGENERAL ABBREVIATIONS
A
ABA ARCHITECTURAL BARRIERS ACT
AC AIR CONDITIONING
AD AREA DRAIN
ADJ ADJUSTABLE / ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ATTEN ATTENUATION
AUTO AUTOMATIC
AV AUDIO / VISUAL
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BM BENCH MARK / BEAM
BO BOTTOM OF
BOC BACK OF CURB
BOT BOTTOM
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BVL BEVELED
C
CAP CAPACITY
CB CATCH BASIN
CCTV CLOSED CIRCUIT TV
CF CUBIC FEET
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CIP CAST-IN-PLACE
CL CENTER LINE
CLG CEILING
CLR CLEAR / CLEARANCE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECTION / CONNECT
CONST CONSTRUCT / CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR / CORRUGATED
CP CONCRETE PIPE
CS COUNTERSINK
CU CUBIC
CW COLD WATER
D
DBL DOUBLE
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
E
E EAST
EA EACH
ABBREVIATIONS LISTED BELOW ARE GENERAL ABBREVIATIONS ACROSS ALL DISCIPLINES. DISCIPLINE SPECIFIC ABBREVIATIONS MAY SUPERSEDE GENERAL ABBREVIATIONS. REFER TO DISCIPLINE SPECIFIC ABBREVIATIONS SHEETS.
EF EXHAUST FAN
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
ETR EXISTING TO REMAIN
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FB FACE BRICK
FBO FURNISHED BY OWNER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FF FINISH FLOOR
FF&E FIXTURES, FURNITURE & EQUIPMENT
FFE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RATED
FRMG FRAMING
FS FLOOR SINK
FT FOOT/ FEET
FTG FOOTING
FUT FUTURE
G
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
GPM GALLON PER MINUTE
H
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HORIZ HORIZONTAL
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING / VENTILATING / AIR
CONDITIONING
HW HOT WATER
HYD HYDRANT
I
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE (D), (ING)
INFO INFORMATION
INST INSTALL / INSTALLATION
INSUL INSULATE / INSULATION
INT INTERIOR
INV INVERT
J
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
K
KIT KITCHEN
KO KNOCKOUT
L
L LONG / LENGTH
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT (FEET)
LH LEFT HAND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LRG LARGE
LT LIGHT
LTG LIGHTING
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
M
MAS MASONRY
MAX MAXIMUM
MBR MEMBER
MECH MECHANICAL
MED MEDIUM
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MOD MODULAR
MTD MOUNTED
MTG MOUNTING
MTL METAL
N
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NSF NET SQUARE FEET
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD / OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
P
PA PUBLIC ADDRESS
PB PUSH BUTTON
PC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE (D)
PERM PERMANENT
PERP PERPENDICULAR
PL PLATE / PROPERTY LINE
PLUMB PLUMBING
PNL PANEL
PR PAIR
PREFAB PREFABRICATE (D)
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARE (D)
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
PVG PAVING
Q
QTY QUANTITY
R
R RISER / RADIUS
RA RETURN AIR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCE (D), (ING)
REQD REQUIRED
REV REVISED/ REVISION
RH RIGHT HAND
RM ROOM
ROW RIGHT OF WAY
RR RESTROOM
RTU ROOF TOP UNIT
S
S SOUTH
SAN SANITARY SEWER
SCH SCHEDULE
SCRN SCREEN
SECT SECTION
SF SQUARE FOOT (SQFT)
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SPKLR SPRINKLE
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD (SQ YD)
SYM SYMMETRICAL / SYMBOL
SYS SYSTEM
T
TEL TELEPHONE
TEMP TEMPORARY / TEMPERED
THK THICK (NESS)
THRU THROUGH
TO TOP OF
TOC TOP OF CURB / CONCRETE
TOD TOP OF DECK
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOR TOP OF ROOF
TOS TOP OF STEEL
TOW TOP OF WALL
TRANSF TRANSFORMER
TV TELEVISION
TYP TYPICAL
U
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V
VERT VERTICAL
VEST VESTIBULE
VHA VETERANS HEALTH ADMINISTRATION
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
W
W WEST, WIDTH, WIDE
W/ WITH
W/IN WITHIN
W/O WITHOUT
WC WATER CLOSET
WH WALL HYDRANT / WATER HEATER
WT WEIGHT
X, Y, Z, MISC
& AND
@ AT
YD YARD
MR ZAM
00-GI002
GENERAL INFORMATION AND
ABBREVIATIONS 58 & 98
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
100% CONSTRUCTION
DOCUMENTS
12/14/2022
ZMiller Image
PIPE BASEMENT
PIPE BASEMENT
UP UP
DN DN
DOCK
136A
FHCFHC
CHART
EQUIP
ALCOVE
CHART CHART
EQUIP
ALCOVE ALCOVE
CHART
CHART
IP
HOLD
C:
\U se rs\
VA
A rch ite ct
\D oc um en ts\ Re vit
\19
.25 _A
RC
H_
R2 2_ zm ille r4
NR
TZ
.rv t 4/1
3/2
2 7 :06
:51 A
M
MR ZAM
00-GI110
ICRA DIAGRAMS - BUILDING 58
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
100% CONSTRUCTION
DOCUMENTS
12/14/2022
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - BASEMENTF5
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - FIRST FLOORC5
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - SECOND FLOORF1
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - THIRD FLOORC1
NO ICRA BARRIER
REQUIRED
CLASS II PRECAUTION
CLASS III PRECAUTION
CLASS III/IV PRECAUTION
LEGEND
A. ICRA PRECAUTION CLASSIFICATION IS BASED ON VALHALLA'S
UNDERSTANDING OF THE CURRENT USE OF SPACES AT THE TIME OF DESIGN.
VERIFY ALL CLASSIFICATIONS WITH THE VHA INFECTION CONTROL
SUPERVISOR PRIOR TO CONSTRUCTION.
B. AREAS SHOW WORST CASE CLASSIFICATION, LOWER PRECAUTION
CLASSIFICATION MAY BE USED WITHIN MARKED ARES WHEN APPROVED BY
THE VHA COR AND INFECTION CONTROL SUPERVISOR.
C. AT ANY CONNECTION BETWEEN DIFFERING PRECAUTION CLASSIFICATIONS,
PROVIDE BARRIERS IN COMPLIANCE WITH THE MORE RESTRICTIVE
CLASSIFICATION.
FOR
REFERENCE
ONLY
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FHC
AutoCAD SHX Text
EP
AutoCAD SHX Text
FHC
AutoCAD SHX Text
EQUIP ALCOVE
AutoCAD SHX Text
CHART
AutoCAD SHX Text
EQUIP ALCOVE
F-1
P-1
P-2
MECHANICAL SPACE
C:
\U se rs\
VA
A rch ite ct
\D oc um en ts\ Re vit
\19
.25 _A
RC
H_
R2 2_ zm ille r4
NR
TZ
.rv t 4/1
3/2
2 7 :06
:51 A
M
MR ZAM
00-GI111
ICRA DIAGRAMS - BUILDING 58
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
100% CONSTRUCTION
DOCUMENTS
12/14/2022
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - FOURTH FLOORF5
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - FIFTH FLOORC5
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 58 - ATTICF1
NO ICRA BARRIER
REQUIRED
CLASS II PRECAUTION
CLASS III PRECAUTION
CLASS III/IV PRECAUTION
LEGEND
A. ICRA PRECAUTION CLASSIFICATION IS BASED ON VALHALLA'S
UNDERSTANDING OF THE CURRENT USE OF SPACES AT THE TIME OF DESIGN.
VERIFY ALL CLASSIFICATIONS WITH THE VHA INFECTION CONTROL
SUPERVISOR PRIOR TO CONSTRUCTION.
B. AREAS SHOW WORST CASE CLASSIFICATION, LOWER PRECAUTION
CLASSIFICATION MAY BE USED WITHIN MARKED ARES WHEN APPROVED BY
THE VHA COR AND INFECTION CONTROL SUPERVISOR.
C. AT ANY CONNECTION BETWEEN DIFFERING PRECAUTION CLASSIFICATIONS,
PROVIDE BARRIERS IN COMPLIANCE WITH THE MORE RESTRICTIVE
CLASSIFICATION.
FOR
REFERENCE
ONLY
UP
UPUP
UP
ELEV.
P-1
ELEV.
P-2
CRAWL
SPACE
UP
ANALYST 1
ANALYST 2
CODER 3
CODER 4
CODER 5
CODER 6
BB1
DOCK
STATION 3STATION 5
C:
\U se rs\
VA
A rch ite ct
\D oc um en ts\ Re vit
\19
.25 _A
RC
H_
R2 2_ zm ille r4
NR
TZ
.rv t 4/1
3/2
2 7 :06
:51 A
M
MR ZAM
00-GI112
ICRA DIAGRAMS - BUILDING 98
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
Pl an
N or th
True North
100% CONSTRUCTION
DOCUMENTS
12/14/2022
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 98 - BASEMENTF3
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 98 - FIRST FLOORD3
NO ICRA BARRIER
REQUIRED
CLASS II PRECAUTION
CLASS III PRECAUTION
CLASS III/IV PRECAUTION
LEGEND
A. ICRA PRECAUTION CLASSIFICATION IS BASED ON VALHALLA'S
UNDERSTANDING OF THE CURRENT USE OF SPACES AT THE TIME OF DESIGN.
VERIFY ALL CLASSIFICATIONS WITH THE VHA INFECTION CONTROL
SUPERVISOR PRIOR TO CONSTRUCTION.
B. AREAS SHOW WORST CASE CLASSIFICATION, LOWER PRECAUTION
CLASSIFICATION MAY BE USED WITHIN MARKED ARES WHEN APPROVED BY
THE VHA COR AND INFECTION CONTROL SUPERVISOR.
C. AT ANY CONNECTION BETWEEN DIFFERING PRECAUTION CLASSIFICATIONS,
PROVIDE BARRIERS IN COMPLIANCE WITH THE MORE RESTRICTIVE
CLASSIFICATION.
FOR
C:
\U se rs\
VA
A rch ite ct
\D oc um en ts\ Re vit
\19
.25 _A
RC
H_
R2 2_ zm ille r4
NR
TZ
.rv t 4/1
3/2
2 7 :06
:51 A
M
MR ZAM
00-GI113
ICRA DIAGRAMS - BUILDING 98
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
Pl an
N or th
True North
100% CONSTRUCTION
DOCUMENTS
12/14/2022
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 98 - SECOND FLOORF3
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 98 - THIRD FLOORD3
1/8" = 1'-0"
ICRA DIAGRAM - BUILDING 98 - ATTICF1
NO ICRA BARRIER
REQUIRED
CLASS II PRECAUTION
CLASS III PRECAUTION
CLASS III/IV PRECAUTION
LEGEND
A. ICRA PRECAUTION CLASSIFICATION IS BASED ON VALHALLA'S
UNDERSTANDING OF THE CURRENT USE OF SPACES AT THE TIME OF DESIGN.
VERIFY ALL CLASSIFICATIONS WITH THE VHA INFECTION CONTROL
SUPERVISOR PRIOR TO CONSTRUCTION.
B. AREAS SHOW WORST CASE CLASSIFICATION, LOWER PRECAUTION
CLASSIFICATION MAY BE USED WITHIN MARKED ARES WHEN APPROVED BY
THE VHA COR AND INFECTION CONTROL SUPERVISOR.
C. AT ANY CONNECTION BETWEEN DIFFERING PRECAUTION CLASSIFICATIONS,
PROVIDE BARRIERS IN COMPLIANCE WITH THE MORE RESTRICTIVE
CLASSIFICATION.
FOR
F
S
P
S
S
C
ANN
FACP
S
FIRE ALARM CONTROL PANEL, NEW
ANNUNCIATOR PANEL, NEW
NOTIFICATION APPLIANCE CIRCUIT POWER EXTENDER, NEW
AMPLIFIER, NEW
SMOKE DETECTOR, NEW
SUBSCRIPT E - DESIGNATED FOR ELEVATOR RECALL
HEAT DETECTOR, NEW
DUCT DETECTOR, NEW
MANUAL PULL STATION, NEW
STROBE ONLY (CEILING MOUNT), NEW
SPEAKER/STROBE (CEILING MOUNT), NEW
SPEAKER ONLY (WALL MOUNT), NEW
SPEAKER ONLY (CEILING MOUNT), NEW
HORN/STROBE (CEILING MOUNT), NEW
HORN ONLY (WALL MOUNT), NEW
ADDRESSABLE INPUT MODULE, NEW
ADDRESSABLE OUTPUT MODULE, NEW
GAS DETECTOR, CARBON MONOXIDE, NEW
DOOR HOLDER CONNECTION TO FIRE ALARM SYSTEM, NEW
C
C
AIM
AOM
CO
DH
NAC
AMP
F
P
VS
WF
ANN
FACP
FIRE ALARM CONTROL PANEL, TO BE DEMOLISHED
ANNUNCIATOR PANEL, TO BE DEMOLISHED
SMOKE DETECTOR, TO BE DEMOLISHED
HEAT DETECTOR, TO BE DEMOLISHED
DUCT DETECTOR, TO BE DEMOLISHED
MANUAL PULL STATION, TO BE DEMOLISHED
STROBE ONLY (WALL MOUNT), TO BE DEMOLISHED
HORN/STROBE (CEILING MOUNT), TO BE DEMOLISHED
HORN/STROBE (WALL MOUNT), TO BE DEMOLISHED
TAMPER SWITCH, EXISTING TO REMAIN
WATERFLOW SWITCH, EXISTING TO REMAIN
REMOTE INDICATOR LAMP, TO BE DEMOLISHED
ADDRESSABLE INPUT MODULE, TO BE DEMOLISHED
ADDRESSABLE OUTPUT MODULE, TO BE DEMOLISHED
DOOR HOLDER CONNECTION TO FIRE ALARM SYSTEM, EXISTING TO BE REMAIN
ELEVATOR CONTROLLER - EXISTING TO REMAIN
ELEVATOR SHUNT TRIP BREAKER - EXISTING TO REMAIN
C
AIM
AOM
DH
ELEV
SHNT
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022 ML MCP
00-FA001
FIRE ALARM GENERAL NOTES
SCOPE OF WORK
THE SCOPE OF WORK INCLUDES THE DESIGN AND INSTALLATION OF
NEW FIRE ALARM SYSTEM FOR BUILDINGS 58 AND 98 AT VETERANS
AFFAIRS (VA) MEDICAL CENTER IN DANVILLE, ILLINOIS. THE SCOPE OF
WORK INCLUDES THE INSTALLATION OF A COMPLETE FIRE ALARM
SYSTEM WITH VOICE EVACUATION FOR BUILDING 58 FEATURING STAFF
RESPONSE NOTIFICATION AND A HORN/STROBE TEMPORAL 3 GENERAL
EVACUATION ALARM SYSTEM FOR BUILDING 98. THE SYSTEM SHALL
CONSIST OF THE FOLLOWING: NEW FIRE ALARM CONTROL PANELS
(FACP), HEAT DETECTORS, HORN/STROBES (B98), SPEAKER/STROBES
(B58), STROBES, HORNS (B98), SPEAKERS (B58), AND ASSOCIATED
WIRING. THE SYSTEM SHALL BE DESIGNED, INSTALLED AND TESTED IN
ACCORDANCE WITH ALL APPLICABLE CODES, THE VA FIRE PROTECTION
DESIGN MANUAL AND ALL SPECIFICATIONS. THE NEW FIRE ALARM
CONTROL UNITS FOR BUILDING 58 AND 98 MUST BE INTEGRATED INTO
THE CAMPUS MASTER PANEL NETWORK TO ENABLE TO DISTRIBUTION OF
SIGNALS TO THE CENTRAL STATION. THIS CONNECTION INCLUDES THE
DEMOLITION OF EXISTING NETWORK WIRING AND ADDITION OF NEW
NETWORK WIRING.
THE NEW SYSTEM DOES NOT ANTICIPATE THE REUSE OF ANY
COMPONENTS OF THE EXISTING FIRE ALARM SYSTEM SUCH THAT A
BRAND NEW SYSTEM WILL BE INSTALLED. EXISTING CONDUIT AND
BOXES WILL NOT BE REUSED.
THE SYSTEM WILL BE DESIGNED AND INSTALLED TO BE PARALLEL TO
THE EXISTING FIRE ALARM SYSTEMS FOR EACH BUILDING SUCH THAT NO
IMPAIRMENT TO THE EXISTING SYSTEM IS ANTICIPATED. UPON
SUCCESSFUL INSTALLATION, TESTING AND APPROVAL OF THE NEW
SYSTEM, THE CONTRACTOR SHALL COMPLETELY DEMOLISH THE
EXISTING SYSTEM, IN ACCORDANCE WITH THE SPECIFICATIONS.
INCLUDED IN THE SCOPE OF WORK IS THE RECONNECTION OF THE
EXISTING BUILDING 212 FIRE ALARM EQUIPMENT BACK TO THE BUILDING
98 SYSTEM. ALL EXISTING EQUIPMENT AND WIRING IN BUILDING 212
SHALL BE REUSED AND SHALL BE RECONNECTED TO THE NEW BUILDING
98 PANEL. PER DISCUSSIONS WITH ONSITE STAFF, THE SIGNALING LINE
CIRCUIT RUNS FROM BUILDING 212 TO THE BUILDING 98 MAIN FIRE
ALARM CONTROL PANEL. THE CONTRACTOR IS RESPONSIBLE FOR
PROGRAMMING THE NEW BUILDING 98 FIRE ALARM SYSTEM TO MEET
THE CURRENT BUILDING 212 SEQUENCE OF OPERATIONS (IN ADDITION
TO ANY PROGRAMMING UNRELATED TO BUILDING 212). CONTRACTOR
SHALL UTILIZE THE EXISTING FIRE ALARM PROGRAM FOR BUILDING 212
AND INCLUDE IT IN THE NEW FIRE ALARM SYSTEM FOR BUILDING 98.
BUILDING 212 IS NOT DEPICTED IN THIS DRAWING PACKAGE.
APPLICABLE CODES
VA FIRE PROTECTION DESIGN MANUAL, EIGHTH EDITION, JUNE 2021
NFPA 1 FIRE CODE, 2021
NFPA 70 NATIONAL ELECTRICAL CODE, 2020
NFPA 72 NATIONAL FIRE ALARM CODE, 2019
NFPA 90A AIR-CONDITIONING AND VENTILATING SYSTEMS, 2018
NFPA 101 LIFE SAFETY CODE, 2021
GENERAL NOTES
THE AWARDED CONTRACTOR SHALL BE RESPONSIBLE FOR
PRODUCTION OF ALL DESIGN AND SUBMITTAL DOCUMENTS AND
OBTAINING ALL REQUIRED INFORMATION FOR APPROVALS.
ALL DRAWINGS ARE CONCEPTUAL ONLY AND ARE NOT INTENDED TO
BE USED FOR EXACT MEASURE OR FABRICATION. THE QUANTITY
AND LOCATION OF DEVICES/APPLIANCES SHALL INCLUDE, AT A
MINIMUM, THE LAYOUT SHOWN ON THESE DRAWINGS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADDITIONAL
DEVICES/APPLIANCES AS NECESSARY TO COMPLY WITH APPLICABLE
CODES, STATEMENT OF WORK, SPECIFICATIONS, AUDIBILITY, AND
INTELLIGIBILITY. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF SYSTEM COMPONENTS, WIRING AND CONDUIT
WITH ALL OTHER TRADES.
ALL COMPONENTS REQUIRED FOR A WORKING FIRE ALARM SYSTEM
ARE NOT SHOWN ON THESE CONCEPT DRAWINGS. THE
CONTRACTOR SHALL PROVIDE EQUIPMENT AS NECESSARY FOR A
FULLY OPERATIONAL SYSTEM THAT COMPLIES WITH ALL
APPLICABLE CODES, STATEMENT OF WORK, SPECIFICATIONS AND
MANUFACTURER'S REQUIREMENTS. WHERE SURVIVABILITY IS
REQUIRED FOR SYSTEMS EMPLOYING RELOCATION OR PARTIAL
EVACUATION, WIRING INSTALLED IN METAL RACEWAY WITHIN
BUILDINGS THAT ARE PROTECTED THROUGHOUT BY SPRINKLERS
ARE CONSIDERED TO MEET THE NFPA 72 REQUIREMENTS FOR
PATHWAY SURVIVABILITY AS A 2-HOUR PERFORMANCE
ALTERNATIVE THAT HAS BEEN APPROVED BY THE AUTHORITY
HAVING JURISDICTION (VA) AND IS PERMITTED FOR VOICE
COMMUNICATION SYSTEMS IN VA FACILITIES. WHERE SURVIVABILITY
IS REQUIRED AND WHERE FIRE EMERGENCY VOICE/ALARM
CONTROL EQUIPMENT, METAL JUNCTION BOXES, TERMINAL
CABINETS, AND POWER SUPPLIES ARE LOCATED IN A BUILDING
SPRINKLER PROTECTED THROUGHOUT IN ACCORDANCE WITH NFPA
13, AND WHERE THE CONTROL EQUIPMENT IS ALSO PROTECTED IN
ACCORDANCE WITH NFPA 72, 10.4.5, THEY ARE CONSIDERED
PROTECTED BY OTHER EQUIVALENT MEANS TO PROVIDE A 2-HOUR
FIRE RESISTANCE RATING APPROVED BY THE AUTHORITY HAVING
JURISDICTION (VA) MEETING THE REQUIREMENT OF NFPA 72 (2019),
24.4.8.6.6 (3).
THE FIRE ALARM SYSTEM DESIGN AND INSTALLATION SHALL BE IN
ACCORDANCE WITH NFPA 72, VA FIRE PROTECTION DESIGN MANUAL
AND ALL OTHER CODES LISTED ON THIS SHEET.
ALL FIRE ALARM EQUIPMENT SHALL BE INSTALLED PER PROJECT
SPECIFICATION AND THE MANUFACTURER'S INSTRUCTIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND
METHODS OF JOB SAFETY. WORK SHALL BE PERFORMED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND REGULATIONS.
VISIBLE AND AUDIBLE NOTIFICATION APPLIANCES SHALL BE
PROVIDED THROUGHOUT THE AREA INCLUDED IN THE SCOPE OF
WORK WHERE REQUIRED BY NFPA 72, AND VA FIRE PROTECTION
DESIGN MANUAL. CONTRACTOR TO CONFIRM CEILING TYPES AND
HEIGHTS IN THE LOCATIONS OF EQUIPMENT FROM THOSE SHOWN
ON APPROVED SHOP DRAWINGS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR RECTIFYING UNAUTHORIZED NONCOMPLIANT
CHANGES AT NO ADDITIONAL CHARGE TO THE OWNER.
CONTRACTOR TO DEMOLISH EXISTING FIRE ALARM EQUIPMENT,
CIRCUITS AND CONDUIT. DEVICE/APPLIANCE LOCATIONS SHOWN ON
THE DEMOLITION DRAWINGS ARE FOR CONVENIENCE ONLY AND
MAY NOT BE COMPLETE. CONTRACTOR SHOULD PERFORM AN
EXISTING CONDITIONS SURVEY TO ENSURE THAT ALL EXISTING
COMPONENTS ARE REMOVED UPON DEMOLITION OF THE SYSTEM.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RETURN
ALL WIRES TO THE PANEL FREE OF OPENS, GROUNDS, SHORTS
AND/OR ANY OTHER CONDITION THAT MAY PREVENT THE PROPER
OPERATION OF THE FIRE ALARM SYSTEM.
NEW FIRE ALARM DEVICES MUST BE MARKED 'NOT IN SERVICE' UNTIL
THE NEW SYSTEM HAS BEEN TESTED AND ACCEPTED. AFTER THE
NEW SYSTEM IS ACCEPTED, EXISTING APPLIANCES MUST BE
MARKED 'NOT IN SERVICE' UNTIL REMOVED.
PENETRATIONS OF FLOORS AND RATED WALLS MUST BE
FIRESTOPPED BY THE END OF THE WORK SHIFT. IF THERE IS SOME
REASON NOT TO APPLY THE FINAL FIRESTOPPING MATERIAL,
TEMPORARY MATERIALS SUCH AS MINERAL WOOL SHOULD BE
UTILIZED IN THE INTERIM.
INSTALLATION NOTES
CIRCUITS SHALL MEET THE FOLLOWING REQUIREMENTS:
CLASS B SIGNALING LINE CIRCUITS
CLASS B NOTIFICATION APPLIANCE CIRCUITS (NAC)
CLASS B INITIATING DEVICE CIRCUITS (IDC)
CLASS X CIRCUIT BETWEEN PANELS
VISIBLE AND COMBINATION AUDIBLE/VISIBLE ALARM NOTIFICATION APPLIANCES
MOUNTED ON A WALL SHALL BE MOUNTED AT A MINIMUM OF 80 INCHES AND
MAXIMUM OF 96 INCHES ABOVE THE FINISHED FLOOR MEASURED TO THE
BOTTOM OF THE LENS, OR 6 INCHES BELOW THE CEILING MEASURED TO THE
TOP OF THE LENS (WHICH EVER IS LOWER). CEILING-MOUNTED APPLIANCES
MOUNTED IN FINISHED CEILINGS SHALL BE FLUSH TO THE CEILING. CEILING
APPLIANCES IN EXPOSED APPLICATIONS SHALL BE LOCATED ON THE CEILING
OR SUSPENDED BELOW ANY OBSTRUCTIONS.
AUDIBLE-ONLY APPLIANCES MOUNTED ON THE WALL SHALL BE MOUNTED AT A
IN THE GENERAL EVACUATION APPLICATION, AUDIBLE-ONLY APPLIANCES SHALL
BE TAPPED TO PROVIDE AT LEAST 15 DB ABOVE THE AVERAGE AMBIENT SOUND
LEVEL OR 5 DB ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT
LEAST 60 SECONDS.
ALL FIRE ALARM DEVICES/APPLIANCES SHALL BE INSTALLED CENTER OF TILE IN
AREAS WITH 2' X 2' SUSPENDED CEILING TILES. DEVICES SHALL BE INSTALLED IN
QUARTER OR CENTER OF TILE IN AREAS WITH 2' X 4' SUSPENDED CEILING TILES.
ALL FIRE PROTECTION VALVES SHALL BE ELECTRICALLY SUPERVISED BY THE
FIRE ALARM SYSTEM. EACH VALVE SHALL BE INDIVIDUALLY MONITORED. ALL
CONTROL VALVES, WATERFLOW SWITCHES AND TAMPER SWITCH DEVICES
SHOULD BE EXISTING TO REMAIN. FIRE ALARM CONTRACTOR SHALL MAKE ALL
ELECTRICAL CONNECTIONS TO THE ABOVE DEVICES.
DUCT DETECTORS SHALL BE INSTALLED ON THE SUPPLY AND RETURN SIDES OF
THE AIR HANDLING EQUIPMENT WHERE REQUIRED BY NFPA 90A.
ALL INITIATING DEVICES SHALL BE FIELD LOCATED BASED UPON THE LOCATION
OF DIFFUSERS, LIGHTS, AND OTHER POTENTIAL OBSTRUCTIONS.
PROVIDE A PERMANENT LABEL FOR EACH WIRE/CIRCUIT (WITHIN ALL PANELS,
CABINETS AND JUNCTION BOXES) INDICATING IT'S APPLICATION/USE/SERVICE.
ALL WIRING, CABLES, BOXES, TROUGHS AND OTHER RELATED EQUIPMENT
SHALL COMPLY WITH THE NEC.
ALL PENETRATIONS OF FIRE RESISTANCE RATED BARRIERS, WALLS, AND
SHAFT/ASSEMBLIES SHALL BE DRILLED AND SEALED WITH AN APPROVED UL
FIRE-RATED THROUGH-PENETRATION ASSEMBLY. SEE ARCHITECTURAL AND
LIFE SAFETY PLANS FOR LOCATIONS OF SMOKE PARTITION AND FIRE BARRIER
WALLS. ALL PENETRATIONS IN FIRE RESISTANCE-RATED WALLS SHALL BE
FIRESTOPPED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
FIRE ALARM DEVICE LEGEND
58 AND 98
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022 ML MCP
00-FA002
FIRE ALARM SEQUENCE OF
OPERATIONS
1) THE SEQUENCE OF OPERATIONS OF THE FIRE ALARM SYSTEM
SHALL BE PROGRAMMED IN ACCORDANCE WITH THE SEQUENCE OF
OPERATIONS ON THIS SHEET AND THE REQUIREMENTS OF THE
SPECIFICATION AND THE VA DESIGN MANUAL.
2) CONTRACTOR SHALL CONFIRM SEQUENCE OF OPERATIONS AND
ALL REQUIRED PRE-RECORDED MESSAGES WITH THE
CONTRACTING OFFICER/RESIDENT ENGINEER OR DESIGNATED
ALTERNATE PRIOR TO PRODUCING SHOP DRAWINGS AND PRIOR TO
PROGRAMMING THE SYSTEM.
58 AND 98
GENERAL NOTES
NO SCALE
BUILDING 58 FIRE ALARM SEQUENCE OF OPERATIONSF1 NO SCALE
BUILDING 98 FIRE ALARM SEQUENCE OF OPERATIONSF6
LEVEL 5
ATTIC
LEVEL 4
LEVEL 3
LEVEL 2
LEVEL 1
BASEMENT LEVEL
FACP
S
P
S
F
S
P
S
F
S
P
F
S
P
VSWF
S
F
S
P
F
S
P
F
S
P
F
NAC
LLA SMOKE ZONE
1A SMOKE ZONE 1B SMOKE ZONE
2A SMOKE ZONE 2B SMOKE ZONE
3A SMOKE ZONE 3B SMOKE ZONE
4A SMOKE ZONE 4B SMOKE ZONE
5A SMOKE ZONE 5B SMOKE ZONE
6A SMOKE ZONE
NAC
NAC NAC
NAC NAC
NAC NAC
NAC NAC
NAC
S
S
1C SMOKE ZONE
S
S
S
S
S
S
S
S
S
S
AMP
S
NAC
EOLR
EOLR
EOLR EOLR
EOLR EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
AIMAIM
VSWF
AIMAIM
VSWF
AIMAIM
VSWF
AIMAIM
VSWF
AIMAIM
VSWF
AIMAIM
VSWF
AIMAIM
NEW CONNECTION TO CAMPUS
MASTER PANEL NETWORK
ELEV
AOMAIMAOM
SHNT
ELEV
AOMAIMAOM
SHNT
ATTIC
LEVEL 3
LEVEL 2
LEVEL 1
BASEMENT LEVEL
FACP
S
P
S
F
S
P
F
S
P
F
NAC
NAC
NAC
NAC EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
EOLR
NEW CONNECTION TO
CAMPUS MASTER
PANEL NETWORK
VSWF
AIMAIM
VSWF
AIMAIM
VSWF
AIMAIM
S
P
S
F
NAC
EOLR
EOLR
VSWF
AIMAIM
S
P
F
VSWF
AIMAIM
ELEV
AOMAIMAOM
SHNT
FIRE ALARM CONTROL PANEL
BATTERY CABINET (IF REQUIRED)
BLOCKING AND
ATTACHMENT PER
MANUFACTURER'S
RECOMMENDATIONS
FIRE ALARM CONTROL PANEL
BATTERY CABINET (IF REQUIRED)
BLOCKING AND
ATTACHMENT PER
MANUFACTURER'S
RECOMMENDATIONS
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022 ML MCP
00-FA003
FIRE ALARM RISER DIAGRAM AND
DETAILS
1) RISER DIAGRAMS ARE CONCEPTUAL IN NATURE AND ARE NOT
INTENDED TO SHOW A COMPLETE SYSTEM. THE CONTRACTOR
SHALL EXPAND ON THE CONCEPTUAL RISER DIAGRAM FOR A
COMPLETE SYSTEM.
2) THE BIDDING CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH
THE COMPLEXITIES OF THIS BUILDING. THESE DRAWINGS ARE
DIAGRAMMATIC ONLY. THE AWARDED CONTRACTOR SHALL BE
RESPONSIBLE FOR PRODUCTION OF ALL DESIGN AND SUBMITTAL
DOCUMENTS AND OBTAINING ALL REQUIRED INFORMATION FOR
APPROVALS.
3) WIRING LAYOUT AND ROUTING IS CONCEPTUAL. THE CONTRACTOR
IS RESPONSIBLE FOR DESIGNING AND PROVIDING ALL WIRING,
CONDUIT AND ROUTING REQUIRED BY THE SPECIFICATIONS AND
THE VA FIRE PROTECTION DESIGN MANUAL. PATHWAY
SURVIVABILITY, WHERE REQUIRED, IS NOT DEPICTED. THE
CONTRACTOR SHALL BE REQUIRED TO MEET NFPA 72
REQUIREMENTS FOR PATHWAY SURVIVABILITY, IF REQUIRED.
4) WHERE SURVIVABILITY IS REQUIRED FOR SYSTEMS EMPLOYING
RELOCATION OR PARTIAL EVACUATION, WIRING INSTALLED IN
METAL RACEWAY WITHIN BUILDINGS THAT ARE PROTECTED
THROUGHOUT BY SPRINKLERS ARE CONSIDERED TO MEET THE
NFPA 72 REQUIREMENTS FOR PATHWAY SURVIVABILITY AS A
2-HOUR PERFORMANCE ALTERNATIVE THAT HAS BEEN APPROVED
BY THE AUTHORITY HAVING JURISDICTION (VA) AND IS PERMITTED
FOR VOICE COMMUNICATION SYSTEMS IN VA FACILITIES.
5) REFER TO SHEET 00-E-002 FOR ELECTRICAL CONNECTIONS.
NO SCALE
BUILDING 58 FIRE ALARM RISER DIAGRAMD1 NO SCALE
BUILDING 98 FIRE ALARM RISER DIAGRAMD5
58 AND 98
NO SCALE
BUILDING 58 FIRE ALARM CONTROL PANEL ELEVATION VIEW AMBASSADOR AREA C1-4AF1
1) THE FIRE ALARM CONTROL PANEL MUST BE MOUNTED SO THAT CONTROL
UNIT DISPLAYS, VISIBLE INDICATORS, OR CONTROLS SHALL BE MOUNTED
SUCH THAT THE DISTANCE TO THE HIGHEST SWITCH, LAMP, OR TEXTUAL
DISPLAY DOES NOT EXCEED 6 FT ABOVE THE FINISHED FLOOR, AND THE
LOWEST SWITCH, LAMP, OR TEXTUAL DISPLAY SHALL NOT BE LESS THAN 15 IN.
ABOVE THE FINISHED FLOOR, UNLESS OTHERWISE PERMITTED BY THE
AUTHORITY HAVING JURISTICTION.
NO SCALE
BUILDING 98 FIRE ALARM CONTROL PANEL ELEVATION VIEWF4
ELECTRICAL
CLOSET
ALARM
EQUIP
ROOM7
ENTRY
CB-1
ELEVATOR
LOBBY
7A
LAB
STORAGE
7B
MECH
ROOM
7C
STORAGE
PIPE BASEMENT
ST1
STAIR
1A-1
HSK
1A
SPD
MECHANICAL
1B
HSK
1B-2
ELEV
SHAFT
1B-1
ELEV
MECH
ROOM
ELEV
ELEV
ELEV
ELEV
VS
WF
WF
VS
WF
VS
WF
VS
WF
VS
FACP
F
P
P
P
VS
WF
VS
P
AIMAIMAIM
AIMAIMAIM
AIM
AIM
AIM
AIM
AIM
AIM
AIM
PIPE BASEMENT
PIPE BASEMENT
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022 ML MCP
58 - FD101
B58 - BASEMENT FIRE ALARM
DEMOLITION PLAN - AREA A
1/8" = 1'-0"
BUILDING 58 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREA AE6
1) CONTRACTOR TO DEMOLISH EXISTING FIRE ALARM EQUIPMENT,
CIRCUITS AND CONDUIT. DEVICE/APPLIANCE LOCATIONS SHOWN ON THE
DEMOLITION DRAWINGS ARE FOR CONVENIENCE ONLY AND MAY NOT BE
COMPLETE. CONTRACTOR SHOULD PERFORM AN EXISTING CONDITIONS
SURVEY TO ENSURE THAT ALL EXISTING COMPONENTS ARE REMOVED
UPON DEMOLITION OF THE SYSTEM.
MA
TC
HL
IN
E
F7 /58
-F D1
MA
TC
HL
IN
E
F7 /58
-F D1
MATCHLINE
F2/58-FD102
MATCHLINE
F2/58-FD102
1) LOCATION OF EXISTING FIRE ALARM CONTOL UNIT FROM
PREVIOUS RENOVATION OF THE BUILDING.
2) LOCATION OF EXISTING FIBER ENCLOSURE WITH CONNECTION
TO THE CAMPUS NETWORK AND CAMPUS MASTER PANELS.
FIBER ENCLOSURE TO REMAIN AND FIELD WIRING TO THE
EXISTING FIRE ALARM CONTROL UNIT SHALL BE DEMOLISHED
TO ENABLE CONNECTING THE NEW PANEL LOCATED ON THE
FIRST FLOOR INTO THE CAMPUS NETWORK.
1A-1
HSK
1A
SPD
MECHANICAL
1B
HSK
1B-2
ELEV
SHAFT
1B-1
ELEV
MECH
ROOM
MECHANICAL
SPD
10 (1B)
MECHANICAL
TOILET
STORAGE
4A
OFFICE
1C
OFFICE
4B
CLEAN
ROOM
DIRTY
ROOM
PIPE BASEMENT
P
P
P
P
P
P
F
WF
AIM
PIPE BASEMENT
AOM
AOM AIM
7A
LAB
STORAGE
7B
MECH
ROOM
7C
STORAGE
1B-2
ELEV
SHAFT
1B-1
ELEV
MECH
ROOM
WF
VS
VS
P
AIMAIM
AIM
HEAT10
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022
1/8" = 1'-0"
BUILDING 58 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREA BF71/8" = 1'-0"
BUILDING 58 - BASEMENT FIRE ALARM DEMOLITION PLAN - AREAS CF2
ML MCP
58 - FD102
B58 - BASEMENT FIRE ALARM
DEMOLITION PLAN - AREAS B & C
1) CONTRACTOR TO DEMOLISH EXISTING FIRE ALARM EQUIPMENT,
CIRCUITS AND CONDUIT. DEVICE/APPLIANCE LOCATIONS SHOWN ON THE
DEMOLITION DRAWINGS ARE FOR CONVENIENCE ONLY AND MAY NOT BE
COMPLETE. CONTRACTOR SHOULD PERFORM AN EXISTING CONDITIONS
SURVEY TO ENSURE THAT ALL EXISTING COMPONENTS ARE REMOVED
UPON DEMOLITION OF THE SYSTEM.
MATCHLINE
E6/58-FD101
MATCHLINE
E6/58-FD101 MA
TC
HL
IN
E
E6 /58
-F D1
MA
TC
HL
IN
E
E6 /58
-F D1
DN
DOCK
100B
TIP
100A
LOADING
DOCK
SOILED
LINEN
103B
VAULT
104A
REFRIG
104B
TOILET
MORGUE
ST1
STAIR
C1-1
CORRIDOR
E1
ELEVATOR
E1
ELEVATOR
FREIGHT
ELEV
107A
STORAGE
HKPG
OFFICE
OFFICE
NUCLEAR
MEDICINE
ST2
STAIR
CHEMICALS
113A
TOILET
CHANGING
CHANGING
CONTROL
114A
STORAGE113
X-RAY
X-RAY
115A
TOILET
ELEC
117A
TOILET
117B
IMAGING
117C
EMPLOYEE
LOUNGE
102G
RADIOLOGIST
117D
STORAGE
117F
CHIEF
RADIOLOGY
RECEPTION
117G
CONTROL
117H
EQUIPMENT
117I
CT
SCAN
117J
TOILET
117K
PREP
C1-3A
WAITING
CONTROL
X-RAY
119A
TOILET
120C
TOILET
120A
ULTRASOUND
EXAM
C1-3
CORRIDOR
120B
VASCULAR
EXAM
121A
HOT
LAB
NUCLEAR
MEDICINE
121B
NUCLEAR
MEDICINE
121C
OFFICE
ELEC
C1-2
CORRIDOR
121E
OFFICE
IMAGING
RECEPTION
123A
ADMIN
123B
OFFICE
TOILET
TOILET
BLOOD
DRAW
LAB
C1-4
CORRIDOR
C1-4A
AMBASSADOR
AREA
127A
BLOOD
DRAW
SPECIMEN
PROCESSING
C1-0
MAIN
HALLWAY
128B
CONFERENCE
ROOM
128A
OFFICE
OFFICE
PIPATING
LAB
129A
PIPATING
LAB
131A
OFFICE
BLOOD
BANK
HISTOLOGY/
CYTOLOGY
LAB
C1-5
CORRIDOR
OFFICE
F
P
F
P
P
P
P
P
P
P
F
F
A N
N
P
P
F
WF
P
P
F
VS
PIV
AIM
AIM
UP
DN
DOCK
DH
DH
DH
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022
1/8" = 1'-0"
BUILDING 58 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREA AE6
ML MCP
58 - FD103
B58 - FIRST FLOOR FIRE ALARM
DEMOLITION PLAN - AREA A
1) CONTRACTOR TO DEMOLISH EXISTING FIRE ALARM EQUIPMENT,
CIRCUITS AND CONDUIT. DEVICE/APPLIANCE LOCATIONS SHOWN ON THE
DEMOLITION DRAWINGS ARE FOR CONVENIENCE ONLY AND MAY NOT BE
COMPLETE. CONTRACTOR SHOULD PERFORM AN EXISTING CONDITIONS
SURVEY TO ENSURE THAT ALL EXISTING COMPONENTS ARE REMOVED
UPON DEMOLITION OF THE SYSTEM.
MATCHLINE
F2/58-FD104
MATCHLINE
F2/58-FD104
MA
TC
HL
IN
E
F7 /58
-F D1
MA
TC
HL
IN
E
F7 /58
-F D1
1) ALL SPACES ON THIS SIDE OF THE SMOKE BARRIER IS DESIGNATED AS
SMOKE ZONE 1A.
2) ALL SPACES ON THIS SIDE OF THE SMOKE BARRIER IS DESIGNATED AS
SMOKE ZONE 1B.
3) ALL SPACES ON THIS SIDE OF THE SMOKE BARRIER IS DESIGNATED AS
SMOKE ZONE 1C.
1 2 2 3
DOCK
102G
STORAGE 102H
STORAGE
102O
STORAGE
102F
STORAGE
ST4
STAIR
102F
LOUNGE
102I
HVAC
102K
STORAGE
102J
STORAGE
C1-9
CORRIDOR
102M
STORAGE
102N
TOILET
102L
STORAGE
102D
LAB
102G-1
INPATIENT
PHARMACY
102B
INPATIENT
PHARMACY 102C
INPATIENT
PHARMACY
102A
INPATIENT
PHARMACY
103A
CHIEF
OFFICE
C1-8
CORRIDOR
100C
GAS
STORAGE
STAFF
LOUNGE
100B
TIP
100A
LOADING
DOCK
SOILED
LINEN
OFFICE
103B
VAULT
104A
REFRIG
MECH
104B
TOILET
MORGUE
P
F
P P
P
P
P
P
P
P
P
F
WF
VS
AIM
AIM
DOCK
UP
DN
136A
100A
LOADING
DOCK
CONFERENCE
ROOM
128A
OFFICE
OFFICE
PIPATING
LAB
129A
PIPATING
LAB
131A
OFFICE
BLOOD
BANK
AUTOMATED
CHEMISTRY
ELEC
CHEMISTRY134
LAB
134A
LAB
136B
LAB
136A
CHIEF
MICROBIOLOGY
OFFICE
MICROBIOLOGY
136C
LAB
STORAGE
C1-6
CORRIDOR
139A
ELEC
138A
OFFICE
PATHOLOGY
OFFICE
ST3
STAIR
C1-7
CORRIDOR
138E
STORAGE
138D
CHIEF
OFFICE
138C
OFFICE
138B
OFFICE
TOILET
TOILET
HISTOLOGY/
CYTOLOGY
LAB
C1-5
CORRIDOR
MECHANICAL
ROOM
ELECTRICAL
EQUIP
ROOM
EMERGENCY
GENERATOR
P
P
P
F
FF
UP
DN
136A
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022
1/8" = 1'-0"
BUILDING 58 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREA BF71/8" = 1'-0"
BUILDING 58 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN - AREA CF2
ML MCP
58 - FD104
B58 - FIRST FLOOR FIRE ALARM
DEMOLITION PLAN - AREAS B & C
1) CONTRACTOR TO DEMOLISH EXISTING FIRE ALARM EQUIPMENT,
CIRCUITS AND CONDUIT. DEVICE/APPLIANCE LOCATIONS SHOWN ON THE
DEMOLITION DRAWINGS ARE FOR CONVENIENCE ONLY AND MAY NOT BE
COMPLETE. CONTRACTOR SHOULD PERFORM AN EXISTING CONDITIONS
SURVEY TO ENSURE THAT ALL EXISTING COMPONENTS ARE REMOVED
UPON DEMOLITION OF THE SYSTEM.
MATCHLINE
E6/58-FD103
MATCHLINE
E6/58-FD103 MA
TC
HL
IN
E
E6 /58
-F D1
MA
TC
HL
IN
E
E6 /58
-F D1
1) ALL SPACES IN THIS AREA ARE DESIGNATED AS PART OF SMOKE ZONE 1A.
2) ALL SPACES IN THIS AREA ARE DESIGNATED AS PART OF SMOKE ZONE 1B.
FHC
CHART CHART
EQUIP
ALCOVE ALCOVE
CHART
C2-1
CORRIDOR
ANTEROOM
COMM 200
CHUTE
SPD
206A
CHIEF
205A
TOILET
NOURISHMENT
243A
TOILET
1-PATIENT
ROOM 233
1-PATIENT
ROOM
233A
TOILET
JAN
CLOSET
231A
TOILET
1-PATIENT
ROOM
229D
VACANT
TOILET
229C
HEAD
NURSE
HALL 229A
WARD
CLERK
229B
STAFF
LOUNGE
2-PATIENT
ROOM
228A
TOILET
2-PATIENT
ROOM
227A
TOILET
226A
TOILET
2-PATIENT
ROOM
EQUIP
STOR
224A
TOILET
1-PATIENT
ROOM 222
2-PATIENT
ROOM
ELEC
222A
TOILET
2-PATIENT
ROOM
221A
TOILET
CONFERENCE
TOILET
HALL
218B
RESD
LNG/LKR
218A
PROGRAM
SUPPORT
ASSISTANT
C2-5
CORRIDOR
RESIDENT
STAFF
WORK
MEDICAL
DIRECTOR
INTERNAL
MEDICINE
PHYSICIAN
PHYSICIAN
PROGRAM
MANAGEMENT
OFFICER
MID
LEVEL
WORKROOM
ST2
STAIR
#2
CLEAN
SUPPLY/UTILITY
STORAGE
C2-4
CORRIDOR
SUB
N
STAT
COMFORT
SOIL
HOLD
C2-3
CORRIDOR
ST1
STAIR
#1
MED
NURSE
STATION
218C
PHYSICIAN
C2-6
HALL
P
P
P
F
P
P
P
F
P
P
WF
VS
AIM
AIM
FHC
CHART CHART
EQUIP
ALCOVE ALCOVE
CHART
C2-1
CORRIDOR
ANTEROOM
COMM 200
CHUTE
SPD
206A
CHIEF
205A
TOILET
NOURISHMENT
243A
TOILET
1-PATIENT
ROOM 233
1-PATIENT
ROOM
233A
TOILET
JAN
CLOSET
231A
TOILET
1-PATIENT
ROOM
229D
VACANT
TOILET
229C
HEAD
NURSE
HALL 229A
WARD
CLERK
229B
STAFF
LOUNGE
2-PATIENT
ROOM
228A
TOILET
2-PATIENT
ROOM
227A
TOILET
226A
TOILET
2-PATIENT
ROOM
EQUIP
STOR
224A
TOILET
1-PATIENT
ROOM 222
2-PATIENT
ROOM
ELEC
222A
TOILET
2-PATIENT
ROOM
221A
TOILET
CONFERENCE
TOILET
HALL
218B
RESD
LNG/LKR
218A
PROGRAM
SUPPORT
ASSISTANT
C2-5
CORRIDOR
RESIDENT
STAFF
WORK
MEDICAL
DIRECTOR
INTERNAL
MEDICINE
PHYSICIAN
PHYSICIAN
PROGRAM
MANAGEMENT
OFFICER
MID
LEVEL
WORKROOM
ST2
STAIR
#2
CLEAN
SUPPLY/UTILITY
STORAGE
C2-4
CORRIDOR
SUB
N
STAT
COMFORT
SOIL
HOLD
C2-3
CORRIDOR
ST1
STAIR
#1
MED
NURSE
STATION
218C
PHYSICIAN
C2-6
HALL
DH
DH
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
3/3 0/2
2 2
:41 :45
P M
1900 E MAIN ST, DANVILLE, IL 61832
550-22-102100% CONSTRUCTION
VEG 22.02
UPGRADE FIRE PROTECTION AND
EMERGENCY NOTIFICATION
8171 MAPLE LAWN BLVD.
SUITE 320
FULTON, MD 20759
(301) 323-3599
WWW.COFFMAN.COM
DOCUMENTS
12/14/2022
1/8" = 1'-0"
BUILDING 58 - SECOND FLOOR FIRE ALARM DEMOLITION PLAN - AREA AE6
ML MCP
58 - FD105
B58 - SECOND FLOOR FIRE ALARM
DEMOLITION PLAN - AREA A
1) CONTRACTOR TO DEMOLISH EXISTING FIRE ALARM EQUIPMENT,
CIRCUITS AND CONDUIT. DEVICE/APPLIANCE LOCATIONS SHOWN ON THE
DEMOLITION DRAWINGS ARE FOR CONVENIENCE ONLY AND MAY NOT BE
COMPLETE. CONTRACTOR SHOULD PERFORM AN EXISTING CONDITIONS
SURVEY TO ENSURE THAT ALL EXISTING COMPONENTS ARE REMOVED
UPON DEMOLITION OF THE SYSTEM.
MATCHLINE
F2/58-FD106
MATCHLINE
F2/58-FD106
MA
TC
HL
IN
E
F7 /58
-F D1
MA
TC
HL
IN
E
F7 /58
-F D1
1) ALL SPACES ON THIS SIDE OF THE SMOKE BARRIER IS DESIGNATED AS
SMOKE ZONE 2A.
2) ALL SPACES ON THIS SIDE OF THE SMOKE BARRIER IS DESIGNATED AS
SMOKE ZONE 2B.
1 2
205C
PACK/
DISPATCH
205C2
STERILIZERS205C3
AUTO
CART
WASH
205C5
CART
DRY
205C4
ELECTRICAL
205C1
STORAGE 205G
STORAGE
205E
STORAGE/BREAK
ST 4
STAIR
#4
205D
STORAGE
202B
PREP/
ASSEMBLY
205A1
HAC
202C
DECONTAMINATION/
SCOPE
PROCESSING
202A
HAC 205
STORAGE
TOILET
TOILET
C2-1
CORRIDOR
ANTEROOM
COMM 200
CHUTE
SPD
205A
TOILET
P
OFFICE
F
205C
PACK/
DISPATCH
205C2
STERILIZERS205C3
AUTO
CART
WASH
205C5
CART
DRY
205C4
ELECTRICAL
205C1
STORAGE 205G
STORAGE
205E
STORAGE/BREAK
ST 4
STAIR
#4
205D
STORAGE
202B
PREP/
ASSEMBLY
205A1
HAC
202C
DECONTAMINATION/
SCOPE
PROCESSING
202A
HAC 205
STORAGE
TOILET
TOILET
C2-1
CORRIDOR
ANTEROOM
COMM 200
CHUTE
SPD
205A
TOILET
FHC
CHART
EQUIP
ALCOVE
CHART
ANTEROOM
1-PATIENT
ROOM
245A
ANTE
1-PATIENT
ROOM
WORK
244A
TOILET
246A
TOILET
C2-11
CORRIDOR
243A
TOILET
OXYGEN
STORAGE
C2-9
CORRIDOR
1-PATIENT
ROOM
PCC
C2-10
CORRIDOR
2-PATIENT
ROOM
241A
TOILET
240A
TOILET 240
2-PATIENT
ROOM
IV
THERAPY
2-PATIENT
ROOM
238A
TOILET
237A
TOILET
1-PATIENT
ROOM
EQUIP
STORAGE
ELEC
C2-8
CORRIDOR
ST3
STAIR
#3
CLEAN
UTILITY
ELEC
BED
STORAGE
NOURISHMENT
243A
TOILET
1-PATIENT
ROOM 233
1-PATIENT
ROOM
233A
TOILET
JAN
CLOSET
231A
TOILET
1-PATIENT
ROOM
MED
NURSE
STATION
P
F
P
FHC
CHART
EQUIP
ALCOVE
CHART
ANTEROOM
1-PATIENT
ROOM
245A
ANTE
1-PATIENT
ROOM
WORK
244A
TOILET
246A
TOILET
C2-11
CORRIDOR
243A
TOILET
OXYGEN
STORAGE
C2-9
CORRIDOR
1-PATIENT
ROOM
PCC
C2-10
CORRIDOR
2-PATIENT
ROOM
241A
TOILET
240A
TOILET 240
2-PATIENT
ROOM
IV
THERAPY
2-PATIENT
ROOM
238A
TOILET
237A
TOILET
1-PATIENT
ROOM
EQUIP
STORAGE
ELEC
C2-8
CORRIDOR
ST3
STAIR
#3
CLEAN
UTILITY
ELEC
BED
STORAGE
NOURISHMENT
243A
TOILET
1-PATIENT
ROOM 233
1-PATIENT
ROOM
233A
TOILET
JAN
CLOSET
231A
TOILET
1-PATIENT
ROOM
MED
NURSE
STATION
NAC
7'- 6"
5'
1"
5'
5'
3/3
2"
1'
8'
1/1
6"
1'
1/3 2"
1'
1"
1"
1"
0'
1"
1"
9" 6"
3"
3"
1' 1'-
6" 1'
6"
1 1 /2"
1'
2' 1'
6"
1"
1' 3'
2' 1'
3/4
1'
4' 2'
1'
1/2
1' 6'
4' 2'
3/8
1'
8' 4'
3/1
6"
1' 8'
4' 2'
1/4
1'
8' 4'
1/8
1'
00KEYNOTES
KEY PLAN
GENERAL NOTES
Pl an
N or thTrue North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .