523 19 602 Drawings Pages 31 to 68.pdf
PDF 10 MB Posted
- Attached to
- Z2DA--VISN 1 Construction MATOC Federal contract opportunity
- Solicitation number
- 36C24123R0073
About this file
This file appears to contain technical drawings in support of a federal construction contract opportunity issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1. The solicitation seeks construction services under a multiple award task order contract (MATOC) for VISN 1, with an identification number 36C24123R0073. Awards will be made to multiple vendors to provide indefinite delivery indefinite quantity construction services on an as-needed basis. Response submission dates, initial and maximum contract terms, and other salient procurement details are not specified in the drawings appendix file.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--VISN 1 Construction MATOC has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
E-001
ELECTRICAL NOTES AND SYMBOLS
GENERAL ELECTRICAL NOTES:
1. THE GENERAL ELECTRICAL NOTES ON THIS SHEET APPLY TO ALL THE ELECTRICAL DRAWINGS.
2. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL ASPECTS OF THE DESIGN, TO INCLUDE THE WORK OF SUB-TRADES, PRIOR
TO SUBMITTING A BID.
3. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, TRANSITIONS, FITTINGS, CLEARANCES, POSSIBLES
CLASHES, AND ACCESSORIES THAT MAY BE REQUIRED. COORDINATE ALL THE WORK OF ALL THE TRADES TO ENSURE ALL DUCTS, PIPES, CONDUITS, ETC.
DO NOT CONFLICT AND CLEAR STRUCTURAL AND ARCHITECTURAL MEMBERS. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DEVELOPING
COORDINATED SHOP DRAWINGS FOR REVIEW PRIOR TO STARTING INSTALLATION.
4. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BE FULLY COGNIZANT OF ALL CONDITIONS PRIOR TO SUBMITTING BID. REPORT ANY
DISCREPANCIES TO THE ENGINEER PRIOR TO SUBMITTAL OF BID.
5. THE WORK INCLUDES ALL ITEMS OF THE ELECTRICAL SPECIFICATIONS THAT ARE EITHER WRITTEN ON THE DRAWINGS OR SEPARATELY IN A
SPECIFICATIONS BOOK.
6. WHERE THERE IS A CONFLICT ON THE PLANS, SPECIFICATIONS, NOTES, GENERAL NOTES, REFERENCES, PUBLICATIONS, CODES, ETC. WITH RESPECT TO CONSTRUCTION, MATERIALS, PRODUCTS, METHODS, WORKMANSHIP, PROCEDURE, EXECUTION, ETC. THE MOST STRINGENT SHALL BE UTILIZED OR INSTALLED. THE MOST STRINGENT SHALL BE DEFINED AS THE SPECIFICATION OR REQUIREMENT THAT ALLOWS ALL SPECIFICATIONS OR REQUIREMENTS THAT ARE IN CONFLICT TO BE SATISFIED. NO RELIEF OR EXTRA PAYMENT SHALL BE MADE TO THE CONTRACTOR BECAUSE OF THIS INTERPRETATION.
7. ELECTRICAL CONTRACTOR SHALL NOT BEGIN FABRICATION, CUT ANY MEMBERS, OR BEGIN INSTALLATION UNTIL THE SUBMITTALS AND COORDINATED SHOP DRAWINGS HAVE BEEN APPROVED. ANY WORK CONSTRUCTED OR INSTALLED PRIOR TO THE APPROVAL OF SUBMITTALS AND COORDINATED SHOP DRAWINGS SHALL BE AT THE ELECTRICAL CONTRACTOR'S RISK AND SHALL BE REMOVED AND REINSTALLED OR RECONSTRUCTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE AT THE REQUEST OF THE OWNER'S REPRESENTATIVE TO THE COMPLETE SATISFACTION OF THE OWNER'S REPRESENTATIVE.
8. UNLESS STATED OTHERWISE, ALL EXISTING MATERIAL AND EQUIPMENT SHALL REMAIN THE PROPERTY OF THE PROJECT OWNER.
9. THE ELECTRICAL CONTRACTOR SHALL DEVELOP AND PRESENT A CONSTRUCTION PLAN AND WORK SCHEDULE WITH ALL PHASING, STAGING, AND
SEQUENCING OF WORK FOR APPROVAL PRIOR TO THE COMMENCEMENT AND BEGINNING IMPLEMENTATION OF HIS WORK. THE ELECTRICAL CONTRACTOR SHALL DETERMINE PRIOR TO SUBMITTING HIS WORK SCHEDULE, THE SPECIFIC TIME AVAILABILITY OF ALL AREAS AND SPACES AND
DETERMINE WHAT WORK MUST BE DONE DURING "OFF HOURS".
10. WITH THE EXCEPTION OF SIGNIFICANT NOISE GENERATING ACTIVITIES SUCH AS CORE DRILLING, ETC., WORK OUTSIDE OF THE OCCUPIED SPACES, SUCH
AS ON THE ROOF, ETC., MAY BE PERFORMED DURING NORMAL WORKING HOURS.
11. UNLESS SPECIFICALLY NOTED AS EXISTING, ALL ITEMS, EQUIPMENT, AND WORK SHOWN IS NEW AND SHALL BE FURNISHED AND INSTALLED BY THE
ELECTRICAL CONTRACTOR.
12. DURING THE EXECUTION OF THIS CONTRACT, THE SITE AND BUILDINGS WILL BE OCCUPIED AND IN USE. WORK DONE UNDER THIS CONTRACT SHALL BE PERFORMED WITHOUT INCONVENIENCE TO THE OWNER INSOFAR AS POSSIBLE. ALL WORK SHALL BE COORDINATED WITH THE OWNER'S
REPRESENTATIVE AND IS SUBJECT TO THEIR CONTINUOUS APPROVAL.
13. THE CONTRACTOR IS COMPLETELY RESPONSIBLE FOR ALL CHARACTERISTICS OF THE EQUIPMENT THAT HE INTENDS TO INSTALL AND MUST FOLLOW MANUFACTURER RECOMMENDATIONS FOR PROPER INSTALLATION. IF THERE ARE ANY DIFFERENCES IN THE EQUIPMENT SHOWN ON THE DESIGN DRAWINGS AND THE EQUIPMENT TO BE INSTALLED, THE ELECTRICAL CONTRACTOR SHALL MAKE ALL CHANGES AND ADJUSTMENTS TO ACCOMMODATE THE PROPOSED EQUIPMENT AT NO ADDITIONAL COST TO THE OWNER. THIS APPLIES TO ALL SUPPORT SERVICES AND FACILITIES NECESSARY TO PROPERLY INSTALL THE EQUIPMENT TO FUNCTION ADEQUATELY AS PART OF THE SYSTEMS FOR WHICH THEY WERE DESIGNED AND SELECTED. THESE CHARACTERISTICS INCLUDE SUCH THINGS AS WEIGHT, CLEARANCE, DIMENSIONS, ELECTRICAL, MECHANICAL, PLUMBING, AND UTILITY SERVICES, ETC.
ACCOMMODATING SERVICES INCLUDE SUCH THINGS AS DIMENSIONS, LOCATIONS, AND SIZES OF SUPPORTING MEMBERS, PIPE, CONNECTION SIZES, ELECTRICAL SERVICE SIZE AND PROTECTION, ELECTRICAL CONNECTION LOCATION, UTILITY AND PLUMBING CONNECTION SIZES AND LOCATIONS, ETC.
ALL REQUIRED CHANGES TO THE CONTRACT DRAWINGS AND SPECIFICATIONS SHALL BE DESIGNED AND STAMPED BY REGISTERED ENGINEERS IN THE APPROPRIATE DISCIPLINE EMPLOYED BY THE ELECTRICAL CONTRACTOR AND SHALL BE INCLUDED AS PART OF THE EQUIPMENT SUBMITTALS. ALL CHANGES SHALL BE SUBJECT TO THE APPROVAL OF THE PROJECT A/E AND THE OWNER'S REPRESENTATIVE.
14. BEFORE ANY DEMOLITION OR CONSTRUCTION WORK IS BEGUN, THE ELECTRICAL CONTRACTOR AND THE OWNER'S REPRESENTATIVE SHALL SURVEY THE EXISTING BUILDING AREA TO BE MODIFIED AND/OR REPLACED TO ACCURATELY DOCUMENT EXISTING CONDITIONS. THIS SURVEY WILL BE USED BY THE OWNER'S REPRESENTATIVE AT JOB COMPLETION TO DETERMINE WHICH BUILDING/SITE COMPONENTS MUST BE REPLACED WITH NEW.
15. UNLESS STATED OTHERWISE, REQUEST APPROVAL FROM THE OWNER'S REPRESENTATIVE SEVEN DAYS IN ADVANCE FOR THE SHUTDOWN OF ANY
EXISTING SYSTEM.
16. UNLESS STATED OTHERWISE, FINAL ADVANCE NOTICE OF 48 HOURS SHALL BE GIVEN TO THE OWNER'S REPRESENTATIVE PRIOR TO THE PROPOSED
SHUTDOWN OF ANY SYSTEM.
17. PROVIDE ADEQUATE FIRE PROTECTION IN THE ENTIRE CONSTRUCTION AREA FOR THE DURATION OF THE CONSTRUCTION PERIOD. COORDINATE WITH
INSTALLING FIRE PROTECTION CONTRACTOR.
18. ELECTRICAL CONTRACTOR SHALL NOT PENETRATE OR CUT ANY STRUCTURAL MEMBERS NOT SPECIFICALLY SHOWN ON THE DRAWINGS (E.G., JOISTS, BEAMS, ETC.). IF STRUCTURAL MEMBERS CONFLICT WITH ROUTING, CONTACT THE OWNER'S REPRESENTATIVE FOR DIRECTION BEFORE PROCEEDING.
EXERCISE CAUTION IN CUTTING CONCRETE FLOORS AND WALLS TO AVOID EXISTING UTILITIES WHICH MAY BE LOCATED IN AND UNDER CONCRETE
SURFACES.
19. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW OPENINGS IN WALLS, FLOOR, AND ROOF, AND PATCH EXISTING OPENINGS IN CONJUNCTION WITH THE DEMOLITION AND INSTALLATION OF THE NEW BUILDING COMPONENTS. ALL NECESSARY FRAMING, COUNTER-FLASHING, ETC. SHALL BE INCLUDED.
20. FOR ALL FLOOR, WALL, AND ROOF PENETRATION, VERIFY THE LOCATION OF THE EXISTING STRUCTURAL MEMBERS PRIOR TO DRILLING AND CUTTING, RELOCATE OPENINGS AS REQUIRED AND OFFSET DUCTS, PIPES, CONDUIT, ETC.
21. EXISTING DUCTWORK, DOMESTIC COLD WATER PIPING, DOMESTIC HOT WATER PIPING, CHILLED AND HEATING HOT WATER PIPING, WASTE, VENT, FIRE SPRINKLER LINES, FIRE ALARM EQUIPMENT, ELECTRICAL CONDUIT, TELEPHONE CONDUIT, COMMUNICATION CONDUIT, PNEUMATIC TUBING, ETC., MAY HAVE TO BE RELOCATED TO FACILITATE THE INSTALLATION OF THE NEW WORK. THE CONTRACTOR SHALL DETERMINE ALL EXISTING SERVICES THAT REQUIRE RELOCATION PRIOR TO SUBMITTING HIS BID AND INCLUDE ALL COSTS IN THE BID. THERE WILL BE NO EXTRA COMPENSATION TO THE
CONTRACTOR FOR THIS WORK.
22. THE CONTRACTOR IS HEREBY NOTIFIED THAT SOME WORK MAY BE REQUIRED OUTSIDE OF THE AREAS SHOWN ON THESE DRAWINGS. THIS COULD INCLUDE ELECTRICAL WORK, REFRIGERANT LINE ROUTING, CONTROL MODIFICATIONS OR CONNECTIONS AT REMOTE LOCATIONS, CONTROL PANELS, CPU'S, ETC.
23. THE CONTRACTOR SHALL PAY FOR ALL DAMAGE, INCLUDING WATER DAMAGE, TO PROPERTY AND EQUIPMENT CAUSED BY HIS WORK THROUGHOUT THE
CONSTRUCTION AND WARRANTEE PERIOD.
24. PATCH AND PAINT TO MATCH EXISTING, ALL SURFACES DAMAGED BY THE DEMOLITION AND ALL OPENINGS NOT TO BE REUSED.
25. REPAIR DAMAGE TO CEILING, WALLS, ETC. TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE.
26. WHEN A DETAIL OR NOTE IS IDENTIFIED AS TYPICAL, THE ELECTRICAL CONTRACTOR IS TO APPLY THE DETAIL OR NOTE TO EVERY SIMILAR CONDITION, WHETHER OR NOT THE REFERENCED DETAIL OR NOTE IS REPEATED OR REFERENCED.
27. WHERE NO CONSTRUCTION DETAIL IS INDICATED, SUCH WORK SHALL BE SIMILAR TO COMPARABLE WORK DETAILED OR NOTED ELSEWHERE OR TO
MATCH EXISTING CONDITIONS, SUBJECT TO THE APPROVAL OF THE OWNER'S REPRESENTATIVE.
28. THE DEMOLITION SHALL INCLUDE ALL ASSOCIATED ANCHORAGES, HANGERS, SUPPORTS, BRACES, FASTENERS, MASTIC, MORTAR, LATH, AND RELATED
ITEMS. THE EXISTING SUBSTRATE, INCLUDING CONCRETE, MASONRY, METAL FRAMING AND FURRING SHALL BE REPAIRED WHERE DAMAGE BY THE
CONTRACTOR'S WORK.
TIME CLOCK
R
RECTIFIER, CATHODIC PROTECTION SANITARY
ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" [610mm] CENTERS OR AS DESIGNATED ON DRAWINGS), MTD 3'-6" [1067mm] AFF OR AS
INDICATED.
3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &
RECEPTACLE.
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
STARTER, COMBINATION WITH DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
POTHEAD
STRESS CONE
VENTILATOR OR FAN COIL UNIT OUTLET
CONDUIT TERMINATED 6" AFF IN STANDARD BOX FOR
EXTENSION TO EQUIPMENT AS DIRECTED.
CONDUIT TERMINATED W/COUPLING (FLUSH W/FINISHED
FLOOR) FOR EXTENSION TO EQUIPMENT AS DIRECTED.
ELECTRICAL SYMBOLS - POWER PLAN
JUNCTION BOX
TRANSFORMER, PLAN
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
WYE CONNECTION
DUCT, CELL FLOOR HEADER
DUCT, TROLLEY
DUCT, UNDERFLOOR JUNCTION BOX
EARTH GROUND
LADDER CABLE TRAY
BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER
OF CIRCUITS, NEUTRAL, AND SWITCH LEG CONDUCTORS.
ONE SEPARATE GREEN GROUNDING CONDUCTOR SHALL
BE PROVIDED FOR EACH HOMERUN; NOT SHOWN
PULL BOX
WIREWAY
RIGID CONDUIT LINE = RC
SUBSTATION
BUSWAY
FLOOR OUTLET, DATA COMMUNICATION
OUTLET, DATA COMMUNICATION
PUSH BUTTON
DISTRIBUTION PANEL
LIGHTING PANEL
PANELBOARD CABINET, FLUSH MOUNTED
PANELBOARD CABINET, SURFACE MOUNTED
RECEPTACLE, CLOCK HANGER
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX ON EMERGENCY POWER
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE, QUADRAPLEX
RECEPTACLE, SINGLE
RECEPTACLE, SINGLE WITH SWITCH
RECEPTACLE, SPECIAL PURPOSE
A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R.
B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R.
C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R.
D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R.
E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R.
F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R.
G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-30R.
H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R.
RECEPTACLE, SWITCHED DUPLEX
DIRECT BURIAL CABLE = DB
POWER DUCT DIRECT BURIED
PVC CONDUIT MIN 18" DEPTH = P
HI VOLTAGE SWITCH ON CONCRETE PAD
LOW VOLTAGE SWITCH ON CONCRETE PAD
DUAL POWER AND TELECOMMUNICATIONS MANHOLE
DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE,
GROUNDING TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE
CORD (CENTER LINE OF OUTLET: 6'-6" [1981mm] AFF. MINIMUM).
ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" [610mm] CENTERS OR AS DESIGNATED ON DRAWINGS), MTD 3'-6" [1067mm] AFF OR
AS INDICATED.
3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &
RECEPTACLE.
RELAY; LETTER INDICATES RELAY TYPE
50 = INSTANTANEOUS OVERCURRENT OR RATE-OF-RISE
51 = AC-TIME OVERCURRENT
67 = AC-DIRECTIONAL OVERCURRENT
86 = LOCK OUT
ELECTRICAL SYMBOLS - POWER PLAN
SWITCH
F = FUSED SWITCH K = KEY OPERATED
L = LOCK LM= LOW VOLTAGE MASTER
M = MANUAL MOTOR STARTING MC= MOMENTARY CONTACT
MP= MOTOR SNAP WITH PILOT LIGHT P = WITH PILOT LIGHT
(THERMAL TYPE)
PB= PUSH BUTTON STATION RC= REMOTE CONTROL
WP= WEATHER PROOF X = EXPLOSION PROOF
VARIABLE FREQUENCY DRIVE
SWITCH, CEILING MOUNTED PULL
SWITCH (# SUBSCRIPT AS INDICATED BELOW):
BLANK = SINGLE POLE 2 = DOUBLE POLE
3 = THREE-WAY 4 = FOUR-WAY
D = DIMMER K = KEY OPERATED
LV= LOW VOLTAGE P = WITH PILOT LIGHT
LM= LOW VOLTAGE MASTER RC= REMOTE CONTROL
PB= PUSH BUTTON STATION WP= WEATHER PROOF
T = TIMER OPERATED Mo= OCCUPANCY SENSOR
RECESSED DOWNLIGHT FIXTURE, LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED LED, 2'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED LED, 1'x4';
LETTER INDICATES TYPE.
ELECTRICAL SYMBOLS - LIGHTING PLAN
LIGHT FIXTURE, RECESSED LED, 1'x8';
LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED LED, 2'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED LED, 1'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED LED, 1'x8';
LETTER INDICATES TYPE.
LIGHT FIXTURE, LED EMERGENCY;
LETTER INDICATES TYPE.
LIGHTING, ONE HEAD EMERGENCY BATTERY POWER
STREET LIGHT WITH BRACKET
LIGHT POLE, ONE LUMINAIRE
LIGHTING, EXTERIOR BUILDING
LIGHTING, TWO HEAD EMERGENCY BATTERY POWER
LIGHTING, THREE HEAD EMERGENCY BATTERY POWER
EXTERIOR FLOOD LIGHT
EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL ARROWS AND FACES AS SHOWN
EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL ARROWS AND FACES AS SHOWN
LIGHT FIXTURE, RECESSED LED, 2'x2';
LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED LED, 2'x2';
LETTER INDICATES TYPE.
LIGHT TRACK WITH HEADS AS SHOWN
LIGHT FIXTURE, STRIP/INDUSTRIAL LED; LETTER INDICATES TYPE.
LIGHT FIXTURE, WALL MOUNTED
LIGHT FIXTURE, BOLLARD
LIGHT FIXTURE, DIRECTIONAL
LIGHT POLE, TWO LUMINAIRES
RECEPTACLE, QUADRAPLEX, GFCI PROTECTED
GFCI
FUSE
SWITCH
VFD
E SITE LIGHTING DIRECT BURIED
PVC CONDUIT MIN 18" DEPTH = E
NUC UNDERGROUND CONTROLS
PVC CONDUIT 18" DEPTH = NUC
MISC SYMBOLS
NEW PERIMETER FENCE. REFER TO CIVIL
SHEETS FOR ADDITIONAL INFORMATION
FC1-01
C1-2
CORRIDOR
RESTROOM
LOBBY
C1-4 C1-5
C1-37
OFFICE LOCKER R
OFFICE
CORRIDOR
POLICE POLICE
ARMORY
POLICE
WINDOW C1-38
POLICE
C1-38
POLICE
POLICE STATION LIGHTING DEMOLITION PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1/4" = 1'-0"ED-101
ED-101
POLICE STATION LIGHTING DEMOLITION
PLAN
KEY PLAN - FIRST FLOOR
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
KEYED NOTES:
DEMOLISH EXISTING 2X2 LIGHT FIXTURE. CONTRACTOR SHALL REMOVE CONDUIT AND CIRCUIT BACK TO PANEL.1
1 1
ESTEY ST.
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL DEMOLITION PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
ED-102
ED-102
SITE ELECTRICAL DEMOLITION PLAN
KEY PLAN - CAMPUS
KEYED NOTES:
DEMOLISH EXISTING LIGHT POLE AND LIGHT. CONTRACTOR SHALL PULL
ASSOCIATED WIRING BACK.1
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY OBSTRUCTIONS SHALL BE BROUGHT TO EOR AND VA COR FOR FURTHER INSTRUCTIONS PRIOR TO EXCAVATION.
N E
Y S
T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
A R
C O
L A
S T
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
ED-103
ED-103
KEY PLAN - CAMPUS
SITE ELECTRICAL DEMOLITION PLAN
KEYED NOTES:
DEMOLISH EXISTING LIGHT POLE AND LIGHT. CONTRACTOR SHALL PULL
ASSOCIATED WIRING BACK.1
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY OBSTRUCTIONS SHALL BE BROUGHT TO EOR AND VA COR FOR FURTHER INSTRUCTIONS PRIOR TO EXCAVATION.
ELECTRICAL DEMOLITION PLAN
V
E R
G R
E E
N S
T
K E
N N
E Y
S T
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
ED-104
ED-104
KEY PLAN - CAMPUS
SITE ELECTRICAL DEMOLITION PLAN
KEYED NOTES:
DEMOLISH EXISTING LIGHT POLE AND LIGHT. CONTRACTOR SHALL PULL
ASSOCIATED WIRING BACK.1
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY
H
A T
H S
T R
E E
T
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
ED-105
ED-105
KEY PLAN - CAMPUS
SITE ELECTRICAL DEMOLITION PLAN
KEYED NOTES:
DEMOLISH EXISTING LIGHT POLE AND LIGHT. CONTRACTOR SHALL PULL
ASSOCIATED WIRING BACK.1
1 1
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
ED-106
ED-106
KEY PLAN - CAMPUS
SITE ELECTRICAL DEMOLITION PLAN
KEYED NOTES:
DEMOLISH EXISTING LIGHT POLE AND LIGHT. CONTRACTOR SHALL PULL
ASSOCIATED WIRING BACK.
EXISTING GUARD HOUSE SHALL BE REMOVED (REFER TO CIVIL FOR
ADDITIONAL INFORMATION). CONTRACTOR SHALL REMOVE CIRCUITS AND
CONDUIT BACK TO PANEL. EXISTING CAMERAS EQUIPMENT SHALL BE
MAINTAINED AND OPERATIONAL.
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY OBSTRUCTIONS SHALL BE BROUGHT TO EOR AND VA COR FOR FURTHER INSTRUCTIONS PRIOR TO EXCAVATION.
V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
ED-107
ED-107
KEY PLAN - CAMPUS
SITE ELECTRICAL DEMOLITION PLAN
KEYED NOTES:
DEMOLISH EXISTING LIGHT POLE AND LIGHT. CONTRACTOR SHALL PULL
ASSOCIATED WIRING BACK.1
GENERAL ELECTRICAL DEMOLITION NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E E
E
E
E
E
P P
P
P P
P
P
P
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0" E-101
E-101
ELECTRICAL PLAN
KEY PLAN - CAMPUS
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR DETAILS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
9. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY OBSTRUCTIONS SHALL BE BROUGHT TO EOR AND VA COR FOR FURTHER INSTRUCTIONS PRIOR TO EXCAVATION
KEYED NOTES:
NEW SLIDING GATE OPERATOR TO BE POWERED BY EXISTING EMERGENCY POWER INFRASTRUCTURE.
INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE #10
AWG WITH 1" CONDUIT. USE PANEL LBR2, LOCATED ON WEST WALL OF BOILER PLANT.
NEW VEHICULAR ACCESS CONTROL GATE OPERATOR TO BE POWERED BY EXISTING EMERGENCY
POWER INFRASTRUCTURE. INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER.
CONDUCTOR SIZE SHALL BE #10 AWG WITH 1" CONDUIT. USE PANEL LBR2 LOCATED ON WEST WALL OF
BOILER PLANT.
SG-1
LBR2
Y S
T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
A R
C O
L A
S T
E
E
E
E E
E E
E E
E E
E
E
E
EEEE
E
E
E
E
E E
E
E
E
E
E E
E
E
E
E E
E
E
E
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0" E-102
E-102
ELECTRICAL PLAN
KEY PLAN - CAMPUS*ELECTRICAL WORK IN THIS AREA IS LIGHTING AND CAMERAS ONLY. REFER TO ADDITIONAL SHEETS
FOR INFORMATION. DRAWING SHOWN FOR CLARITY ONLY*
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR DETAILS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
9. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY OBSTRUCTIONS SHALL BE BROUGHT TO EOR AND VA COR FOR FURTHER INSTRUCTIONS PRIOR TO EXCAVATION
E R
G R
E E
N S
T
K E
N N
E Y
S T
E
E
E
E
E
E
E
E
E
E E E E E
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0" E-103
E-103
ELECTRICAL PLAN
KEY PLAN - CAMPUS*ELECTRICAL WORK IN THIS AREA IS LIGHTING ONLY. REFER TO ADDITIONAL SHEETS FOR
INFORMATION. DRAWING SHOWN FOR CLARITY ONLY*
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR DETAILS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
A T
H S
T R
E E
T
E
E
E
E
E E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E E
E E
E
E
E
E
E
E
E E E E E E E
E
E
E
E
E
P
P
P
P
P
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0" E-104
E-104
ELECTRICAL PLAN
KEY PLAN - CAMPUS
KEYED NOTES:
NEW SLIDING GATE OPERATOR TO BE POWERED FROM SUBPANEL 7EPH LOCATED WITHIN BLDG 7.
INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE #10 AWG
WITH 1" CONDUIT.
EXISTING PANEL NEP SHALL BE UPSIZED. CONTRACTOR SHALL REPLACE EXISTING TRANSFORMER WITH NEW DRY-TYPE TRANSFORMER. RE-FEED EXISTING CIRCUITS FROM EXISTING PANEL NEP TO NEW
60-SPACE PANEL WITH NEW CIRCUIT BREAKERS. REFER TO ELECTRICAL DETAIL SHEETS FOR
ADDITIONAL INFORMATION.
NEW GUARD HOUSE LIGHTS AND RECEPTACLES TO BE POWERED FROM PANEL NEP LOCATED WITHIN BLDG 1 GENERATOR ROOM. INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER.
CONDUCTOR SIZE SHALL BE #10 AWG WITH 1" CONDUIT.
NEW GUARD HOUSE HVAC TO BE POWERED FROM PANEL NEP LOCATED WITHIN BLDG 1 GENERATOR ROOM. INSTALL NEW 120 VOLT, 30 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE
#10 AWG WITH 1" CONDUIT.
NEW RETRACTABLE ANTI-RAM WEDGES TO BE POWERED FROM PANEL NEP LOCATED WITHIN BLDG 1 GENERATOR ROOM. INSTALL NEW 208 VOLT, 35 AMP, TWO-POLE CIRCUIT BREAKER. CONDUCTOR SIZE
SHALL BE #10 AWG WITH 1" CONDUIT.
NEW SLIDING GATE OPERATOR TO BE POWERED FROM PANEL NEW PANEL NEP LOCATED WITHIN BLDG 1 GENERATOR ROOM. INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR
SIZE SHALL BE #10 AWG WITH 1" CONDUIT.
SG-1
SG-1
WG-1
7EPH
NEP
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR DETAILS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
C O
C O
E
EEEEEEEEE
E E E E E E
E
E
E
E
E E
E
E
E
E
E
E
E E
E E
E E
E E
PP
P P
P P
P P
PP
P
P
P P P P P P P P P P
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0" E-105
E-105
ELECTRICAL PLAN
KEY PLAN - CAMPUS
KEYED NOTES:
NEW SLIDING GATE OPERATOR TO BE POWERED FROM PANEL P2G WITHIN EMPLOYEE PARKING
GARAGE. INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE
#10 AWG WITH 1" CONDUIT.
INSTALL NEW 100A, 40 SPACE 120/208V SUBPANEL (DPS21C) FED FROM SPARE IN DPS21. NEW SUBPANEL
WILL REQUIRE A NEW DRY-TYPE TRANSFORMER FROM SPARE. INSTALL NEW SUBPANEL AND
TRANSFORMER WITHIN ROOM F1-11. REFER TO DETAILS SHEET FOR ADDITIONAL INFORMATION.
NEW GUARD HOUSE LIGHTS AND RECEPTACLES TO BE POWERED FROM PANEL DPS21C IN ROOM F1-11.
INSTALL NEW 120 VOLT, 20 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE #10 AWG
WITH 1" CONDUIT.
NEW GUARD HOUSE HVAC TO BE POWERED FROM PANEL DPS21C IN ROOM F1-11. INSTALL NEW 120 VOLT, 30 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE #10 AWG WITH 1" CONDUIT.
EXACT CONNECTION LOCATIONS TO BE COORDINATED WITH VA.
NEW RETRACTABLE ANTI-RAM WEDGES TO BE POWERED FROM PANEL DPS21C IN ROOM F1-11. INSTALL NEW 208 VOLT, 35 AMP, TWO-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE #8 AWG WITH 1"
CONDUIT EACH.
NEW ICE MELT SYSTEM TO BE POWERED FROM PANEL 1C2 IN ROOM C1-21. INSTALL NEW 120 VOLT, 50 AMP, SINGLE-POLE CIRCUIT BREAKER. CONDUCTOR SIZE SHALL BE #10 AWG WITH 1" CONDUIT.
CONTRACTOR SHALL PERFORM A 30-DAY LOAD STUDY ON PANEL TO ENSURE CAPACITY. IF
INSUFFICIENT CAPACITY EXISTS, CONTRACTOR SHALL ALERT EOR AND VA COR FOR FURTHER
INSTRUCTIONS.
3 5
E-301
SG-1
SG-1
WG-1 WG-1
DPS21C
DPS21
F1-11
C1-21
P2G
WG-1
WG-15
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR DETAILS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
E E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
ELECTRICAL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0" E-106
E-106
ELECTRICAL PLAN
KEY PLAN - CAMPUS*ELECTRICAL WORK IN THIS AREA IS LIGHTING AND CAMERAS ONLY. REFER TO ADDITIONAL SHEETS
FOR INFORMATION. DRAWING SHOWN FOR CLARITY ONLY*
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR DETAILS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
PPP
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
C O
C O
ICE MELT ENLARGED PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1/2" = 1'-0"E-301
E-301
ENLARGED ICE MELT PLAN
ICE MELT NOTES:
1. NEW ICE MELT SYSTEM SHALL BE INSTALL IN NEW CONCRETE SIDEWALK AND ASPHALT ROADWAY. SEE CIVIL FOR
ADDITIONAL INFORMATION.
2. REFER TO SHEET E-501 & E-105 FOR ELECTRICAL REQUIREMENTS.
3. SYSTEM SHALL BE CONTROLLED UTILIZING WATTS CONTACTORPRO PANEL PM-L3 CAPABLE OF AUTOMATIC OR
MANUAL OPERATION, ADJUSTABLE TRIGGER TEMPERATURE AND ADJUSTABLE DRYING CYCLE. PLACE NEW
CONTROL PANEL WITHIN ROOM C1-21.
PM-2
PM-1
PM-1
PM-2
10'
2'
2'
6"
20'2'
2'
6"
KEY PLAN - CAMPUS
CORRIDOR
RESTROOM
LOBBY
C1-4 C1-5
C1-37
OFFICE LOCKER R
OFFICE
CORRIDOR
POLICE POLICE
ARMORY
POLICE
WINDOW C1-38
POLICE
C1-38
POLICE
POLICE STATION LIGHTING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1/4" = 1'-0"EL-101
EL-101
POLICE STATION LIGHTING PLAN
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. SEE DETAIL 5 ON SHEET E501 FOR PENETRATION DETAIL.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
KEYED NOTES:
INSTALL NEW 2X2 LIGHT LED FIXTURE. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET E-501.1
KEY PLAN - FIRST FLOOR
A A
A
A
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E E
E
E
E
E
P P
P
P P
P
P
P
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
SITE LIGHTING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
EL-102
EL-102
SITE LIGHTING PLAN
KEY PLAN - CAMPUS
KEYED NOTES:
INSTALL NEW LIGHT POLE. REFER TO LIGHT FIXTURE SCHEDULE ON
SHEET E-501 FOR ADDITIONAL INFORMATION.1
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. NEW CIRCUITS FOR SITE LIGHTING SHALL BE INSTALLED, CONNECTING TO THE EXISTING LIGHTING CIRCUITS.
CONDUCTOR SIZE SHALL BE #10 AWG. CONDUITS SHALL BE 1" RIGID SCH. 80 PVC AND SHALL BE DIRECT BURIED IN
ACCORDANCE WITH PROJECT SPECIFICATIONS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
9. SITE LIGHTING BID INFORMATION:
9.1. BASE BID: PROVIDE COMPLETE SITE LIGHTING SYSTEM INCLUDING, BUT NOT LIMITED TO, LIGHT POLES, LIGHT
FOUNDATIONS, LIGHT FIXTURES, CONDUITS, CONDUCTORS, CIRCUITS, SITE TRENCHING AND PATCHING
ASSOCIATED WITH SITE LIGHT SYSTEM SHOWN ON PLANS AND IN SPECIFICATIONS.
9.2. DEDUCT ALTERNATE #1: PROVIDE COST FOR ELIMINATING COMPLETE SITE LIGHTING SYSTEM, INCLUDING ALL COMPONENTS AND WORK ASSOCIATED WITH LIGHT SYSTEM SHOWN ON PLANS AND IN SPECIFICATIONS.
10. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY OBSTRUCTIONS SHALL BE BROUGHT TO EOR AND VA COR FOR FURTHER INSTRUCTIONS PRIOR TO EXCAVATION
NEW ELECTRICAL DIRECT-BURIED PVC CONDUIT FOR LIGHTING
NEW POLE MOUNTED SITE LIGHT FIXTURE
E
LEGEND
SL-1
1SL-1
1SL-1
Y S
T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
A R
C O
L A
S T
E
E
E
E E
E E
E E
E E
E
E
E
EEEE
E
E
E
E
E E
E
E
E
E
E E
E
E
E
E E
E
E
E
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
SITE LIGHTING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
EL-103
EL-103
SITE LIGHTING PLAN
KEY PLAN - CAMPUS
1SL-1
1SL-1
1SL-1
SL-1
SL-1
1SL-1
NEW ELECTRICAL DIRECT-BURIED PVC CONDUIT FOR LIGHTING
NEW POLE MOUNTED SITE LIGHT FIXTURE
E
LEGEND
KEYED NOTES:
INSTALL NEW LIGHT POLE. REFER TO LIGHT FIXTURE SCHEDULE ON
SHEET E-501 FOR ADDITIONAL INFORMATION.
NEW SITE LIGHTING CIRCUIT SHALL BE POWERED FROM EXISTING PANEL
PRL1A WITHIN THE PARKING GARAGE. PROVIDE NEW CIRCUIT BREAKERS,
CONDUCTORS AND CONDUIT TO PROVIDE A COMPLETE, OPERATIONAL
SYSTEM.
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS AND
COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER CONTRACTORS.
4. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL AS
DETERMINED BY THE COR.
5. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE REMOVED.
6. ANY WALL PENETRATIONS MADE FOR CONDUIT RUNS SHALL BE PROPERLY SEALED FOR FIRE RATING.
7. NEW CIRCUITS FOR SITE LIGHTING SHALL BE INSTALLED, CONNECTING TO THE EXISTING LIGHTING CIRCUITS.
CONDUCTOR SIZE SHALL BE #10 AWG. CONDUITS SHALL BE 1" RIGID SCH. 80 PVC AND SHALL BE DIRECT BURIED IN
ACCORDANCE WITH PROJECT SPECIFICATIONS.
8. PROVIDE MEANS OF DISCONNECT FOR ALL NEW EQUIPMENT.
9. SITE LIGHTING BID INFORMATION:
9.1. BASE BID: PROVIDE COMPLETE SITE LIGHTING SYSTEM INCLUDING, BUT NOT LIMITED TO, LIGHT POLES, LIGHT
FOUNDATIONS, LIGHT FIXTURES, CONDUITS, CONDUCTORS, CIRCUITS, SITE TRENCHING AND PATCHING
ASSOCIATED WITH SITE LIGHT SYSTEM SHOWN ON PLANS AND IN SPECIFICATIONS.
9.2. DEDUCT ALTERNATE #1: PROVIDE COST FOR ELIMINATING COMPLETE SITE LIGHTING SYSTEM, INCLUDING ALL COMPONENTS AND WORK ASSOCIATED WITH LIGHT SYSTEM SHOWN ON PLANS AND IN SPECIFICATIONS.
10. GENERAL CONTRACTOR IS REQUIRED TO PERFORM UTILITY SURVEY FOR ALL AREAS OF EXCAVATION. ANY
E R
G R
E E
N S
T
K E
N N
E Y
S T
E
E
E
E
E
E
E
E
E
E E E E E
SOUTH HUNTINGTON AVE
E V
E R
G R
E E
N S
T
K E
N N
E Y
S T
N
IR
A A
V E
G R
O T
T O
G L
E N
R D
ESTEY ST.
H E
A T
H S
T R
E E
T
A R
C O
L A
S T
SITE LIGHTING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
100% BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
17 MARCH 2023Revisions: Date:
CAMPUS
523-19-602
150 SOUTH HUNTINGTON AVENUE, BOSTON MA
VAMC BOSTON
JAMAICA PLAIN CAMPUS
SITE SECURITY UPGRADES
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397 Russell DiNardo, AIA NY 031521-1
A/E:
WATSON ENGINEERING
4500 STATE ROUTE 434
APALACHIN, NY 13732
PHONE: (607) 223-4334
EMW MAK
1" = 20'-0"
EL-104
EL-104
SITE LIGHTING PLAN
KEY PLAN - CAMPUS
1SL-1
1SL-1
1SL-1
KEYED NOTES:
INSTALL NEW LIGHT POLE. REFER TO LIGHT FIXTURE SCHEDULE ON
SHEET E-501 FOR ADDITIONAL INFORMATION.1
NEW ELECTRICAL DIRECT-BURIED PVC CONDUIT FOR LIGHTING
NEW POLE MOUNTED SITE LIGHT FIXTURE
E
LEGEND
GENERAL ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT…
This is the start of the file's text. The full file is on GovTribe.