About this file

This floor plan drawing depicts the second floor layout of a Veterans Health Administration medical facility. It shows the placement of various rooms including examination rooms, offices, corridors, and other clinical spaces. Key details include labels for room numbers and types, as well as notes for partition types between rooms. The drawing also contains revision histories and references other construction documents.

The related federal contract opportunity is a solicitation seeking proposals for an access control and security system upgrade project including miscellaneous interior improvements at the same Veterans Health Administration medical facility. The solicitation includes an attached RFP document. Offerors are invited to propose solutions for upgrading security and access control systems along with other interior construction work. The solicitation was issued by the Department of Veterans Affairs VHA VISN 16 agency. It did not specify proposal due dates, award dates, or other procurement details.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Project #520-22-174 Access Control and Security System Upgrades and Misc Interior Improvements-Construction - 36C25622R0123, newest first.
File Type Posted
36C25622R0123 RFI Register Attachment 1.pdf PDF
36C25622R0123 RFI Register 08182022.docx DOCX document
36C25622R0123 RFI Register Attachment 2.pdf PDF
36C25622R0123 0002.docx DOCX document
36C25622R0123 0001.docx DOCX document
52022174 Site Visit.pdf PDF
36C25622R0123 VHA Supplemental Contract Requirements for Combatting COVID-19.docx DOCX document
36C25622R0123 Drawings .pdf PDF
36C25622R0123 RFP.docx DOCX document
36C25622R0123 WD FL20220112 Mod 1 02252022 .docx DOCX document
36C25622R0123 Specifications .pdf PDF
36C25622R0123 ICRA.pdf PDF
36C25622R0123 SOW 06282022 .docx DOCX document
36C25622R0123 EXHIBIT E.docx DOCX document
36C25622R0123 Brand Name JA 52022174 05 July 2022 Redacted.pdf PDF
36C25622R0123 EXHIBIT F.docx DOCX document
36C25622R0123 EXHIBIT B.docx DOCX document
36C25622R0123 EXHIBIT D.docx DOCX document
36C25622R0123 EXHIBIT C.docx DOCX document
36C25622R0123 EXHIBIT A.docx DOCX document
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECOND FLOOR PLAN -

SECTOR 2 - PARTITION

IN-1.02-2A

3A 3A3A3A3A

3A

3A

3A

3A

3A

3A

3A

3A

3A

3A 3A

3A 3A

3A

3A

3A

3A

3A3A

18'-8"

6' -0

5' -0

8' -0

" 10'-7"

3A

08/29/05SUBMITTAL #2 08/29/05

SUBMITTAL #3

SUBMITTAL #4

FINAL SUBMITTAL

REVISION #7

REVISION #8

RECORD DOCUMENTS

RECORD DOCUMENTS

10/31/05

12/25/05

02/02/06

03/17/06

04/25/07

08/27/07

04/15/08

08/08/08

3A

1B

2A

10C

8' -6

REVISION #12

1A2A

1A

14B 14B1A 1A

1A

1A 1A

1A 1A 1A1A 1A 1A

1A 1A

1A

1A 1A

10F

10E

1A

1A 1A

1A

13E

CYUAN

PV

Office of Facilities

Management

HEERY INTERNATIONAL, INC.

999 PEACHTREE STREET, NE

ATLANTA, GEORGIA 30309

CONSULTANTS: PROJECT NAME

COPYRIGHT 2005 BY HEERY

INTERNATIONAL, INC. ALL RIGHTS

RESERVED.THIS DOCUMENT IS

THE PROPERTY OF HEERY

INTERNATIONAL, INC. IT IS TO BE

USED ONLY FOR THE SPECIFIC

PROJECT IDENTIFIED OR REFERRED

TO HEREIN AND IS NOT TO BE USED

ON OTHER PROJECTS OR EXTENSIONS

TO THIS PROJECT, IN WHOLE OR PART,

EXCEPT BY EXPRESS WRITTEN

AGREEMENT WITH AND COMPENSATION

TO HEERY INTERNATIONAL, INC.

REVISIONS DATE KEY PLAN STAMP

05090-00

N/A

TRUE

NORTH

0 8' 16'

VA GULF COAST VETERANS HEALTH CARE SYSTEM

6425 OFFICE PARK PLAZA

NORTH PENSACOLA BLVD.

PENSACOLA, FL 32503

1/8" = 1'-0"

2ND FLOOR PLAN

SEC 1

SEC 3 SEC 4

SEC 5

PROJECT

NORTH

VA FORM 08-6231, OCT 1978

6"

6"

6"

6"A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

F

E

D

C

B

A

987654321 on e ei gh th in ch o ne fo ot

(f or a s he et p lo tte d at

0" x4

2" on e qu ar te r i nc h on e fo ot (f or a s he et p lo tte d at

0" x4 2" th re e ei gh th s in ch o ne fo ot (f or a s he et p lo tte d at

0" x4 2" on e ha lf in ch o ne fo ot

(f or a s he et p lo tte d at

0" x4

2" th re e qu ar te rs in ch o ne fo ot

(f or a s he et p lo tte d at

0" x4

2" on e in ch o ne fo ot (f or a s he et p lo tte d at

0" x4 2" on e an d on e ha lf in ch es o ne fo ot fo r a s he et p lo tte d at

0" x4 2" th re e in ch es o ne fo ot

(f or a s he et p lo tte d at

0" x4

2"

$$DATE$$

$$TIME$$

$$$$$$$$$$$$FILENAME_LONG$$$$$$$$$$$$

$$$$$$PLOTTER$$$$$$

$$$$$$$$$$$$PENTABLE$$$$$$$$$$$$

user:

date plotted:

time plotted:

file name & path:

pen table:

plotter:

$$USER$$

U

SE

R

_F

IL

E$

AL

L_ P

LO

T_

IN

FO

SEC 2

SEC 6

FINAL SUBMITTAL FULLY SPRINKLERED

7 8 9 10 11 12 13

R

Q

P

N

Q.8

M

L

Q.9

'-0

'-0

'-0

'-0

'-4

4'

-8

6' -2

'-8

30'-0"

M.9

RD

OD

SLOPE

RD

AS-2.11

6 / 7

AS-3.12

AS-5.12

AS-5.12

AS-5.11

TYP.

AS-5.11

SIM.

AS-5.13

AS-3.14

AS-3.14

AS-3.17

AS-3.17

2G100

2G102

2G103

2G105

2G106 M

A T

C H

L

IN

E

1G101

PASSAGE

PASSAGE

PASSAGE

PASSAGE

PASSAGE

IVFA

ELECT.OFFICEIMMIT OFFICE OFFICEIMMIT OFFICE

AUDIOBOOTH AUDIOBOOTH

AUDIOBOOTH AUDIOBOOTH

CATSP OFF

STOR.

HEAR AID

GROUP THER

IMMITCALIBRACLERK

IMS OFF

IMS OFF

COMPUTER RM

TEL EQUIP

TEL OP

LASER

CLERK

HSKP.

TLT.

TLT.

BIOMED

STOR.

BIOMED

RECEIVE

BIOMED

SHOP

IMS REPAIR/

STOR.

TELECOM

PERSON

TLT. TLT. VIS FLDSSUB

WAIT

STOR.

PHOTOG

ROOM

TECHS.

TLT.

OFFICE OFFICE CHIEF

OFFICE

FIT/

DISPENS

AUDIOLOGY

EYE CLINIC

EXAM 1 EXAM 2 EXAM 3 EXAM 4 EXAM 5 EXAM 6

EXAM 7EXAM 8 EXAM 9 EXAM 10

OFFICE

WAIT

WAIT

2B100

WAIT

2B101

2B102

2B103 2B104

2B105

2B106

2B107

2B108

2B109

2B110

2B111

2B112

2B113

2B114

2B1152B116

2B117

2B118

2B119

2B120

2B121

2B122

2B123

2B124

2B125

2B126

2B127 2B128

2B129 2B130

2B131

2B132

2B133

2B134 2B135

2B136

2B137

2B138

2B139

2B1412B1422B143

2B144

2B145

2B146

2B147

2B148

2B149 2B150

2B151

2B152

2B153

2B154

2B155

2B156

2B157

2B158

2B159

2B160

2B161

2B162

CORR.

CORR.

CORR.

CORR.

CORR.CORR.

CORR.

CORR.

CORR.

CORR.

CORR.

C2-76 C2-77

C2-78

C2-79

C2-80

C2-81

C2-82

C2-83

CORR. C2-84

C2-85

C2-86

C2-87

C2-88

CORR.

MATCH LINE

M

A T

C H

L

IN

E

SHELVGRACK

ELECTRO/

VESTIBUL

FEC

FEC

FEC

FEC

PTS

IN-4.12

9'-83 4"

6' -0

8' -0

5'-65 8"

'-9

8 "

2'-1"

10'-9"

1'-0"

13'-0"

13'-5"

4"

9'-0"

11'-41 4"

1'-61 2"

'-6

5' -5

1 4 "

6'-31 4"

4'-25 8"

9'-0"

P

LA

ST

IC

L

AM

C

O U

N

TE

R T

O P

P

LA

ST

IC

L

AM

C

O U

N

TE

R T

O P

COUNTER TOP

PLASTIC LAM.

P

EG

BD

C2-76A

VESTIBULE

IN-8.05

IN-8.05

P

LA

ST

IC

L

AM

C

O U

N

TE

R T

O P

2' -8

1 8 "

1' -8

2"

FVC

FLOOR PLAN LEGEND

FIRE EXTINGUISHER CABINET

FIRE VALVE CABINET (SEE IN-6.03

FOR INSTALLATION IN RATED PARTITIONS)

PNEUMATIC TUBE STATION

(SEE IN-5.21 FOR TYPICAL DETAILS)

ACCESS FLOORING

"VV", "VC" OR "CF" FURNITURE OR EQUIPMENT

FEC

FVC

PTS

X PARTITION TYPE (SEE IN-6.01 & IN-6.02)

Smoke Partition

1-Hour Rated

2-Hour Rated

1-Hour Rated Fire & Smoke Partition

2C136

TRIAGE Room Name Room Number

"CC" EQUIPMENT (SEE EQUIPMENT DRAWINGS

Q-1.01-1A THROUGH Q-1.02-14A FOR

EQUIPMENT LAYOUTS)

REVISION #1 - PARTITION TYPE REVISIONS19'-6"

3' -8

30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 22'-0"

9'-6" 10'-91 4"

'-7

1 2 " 6'

-5 1 4 "

6' -5

1 4 " 6'

-0

'-0

'-9

6' -0

'-3

3' -8

1 4 "

'-6

11'-23 4" 11'-4"

11'-3" 11'-4" 7'-0"

8'-0" 9'-5" 11'-7"

9'-13 4"

'-7

1 4 " 9'

-1 0"

8' -6

4 "

1 4 "

7' -2

'-3

4 "

'-6 1 4 "

'-9

4 "

'-3

22'-0"6'-0"11'-43 4"10'-2"10'-8"10'-8"10'-8"6'-51

4"

5'-41 8" 5'-11" 11'-0" 11'-0" 11'-0" 12'-11

4"

9'-61 2"

2' -1

11 4 "

'-6

9' -6

4 "

7' -0

8 "

6' -5

1 4 " 6'

-7 1 8 "

6' -0

'-4

1 2 " 6'

-0

'-0

6'-83 4"

1'-91 2"

7'-2" 8'-51 4"

1'-51 4"

10'-2" 11'-43 4" 7'-0"

9'-93 8"

7'-101 4" 10'-4" 10'-8" 10'-8" 10'-8" 9'-93

4"

8" 3'

-5 8 "

16'-11 4" 13'-11

4"

File details come from the government source that posted it. Updated .