515-18-109 Bid Drawings - Signed_Part5.pdf
PDF 14 MB Posted
- Solicitation number
- 36C25020B0058
About this file
This document outlines a federal contract opportunity to renovate the outpatient pharmacy and urgent care center at the Battle Creek Healthcare System in Battle Creek, Michigan. The solicitation number is 36C25020B0058 and seeks bids to furnish all labor, materials, supervision, equipment, tools and other necessary resources for the project according to contract specifications, drawings, terms and conditions. An organized site visit is scheduled and sealed bids must be delivered to the specified address by 2:00PM on September 10, 2020. The project number is 515-18-109. This procurement is a 100% set-aside for Service Disabled Veteran Owned Small Businesses and has a $39.5 million small business size standard. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Covid Instructions.docx | DOCX document | |
| 36C25020B0058 0002.docx | DOCX document | |
| 515-18-109 Pre-Bid Attendance Sheet.pdf | ||
| RFi Answers.docx | DOCX document | |
| 515-18-109 Bid Drawings - Signed_Part1 - reissue.pdf | ||
| 36C25020B0058 0001.docx | DOCX document | |
| 515-18-109 Bid Specifications_Part3.pdf | ||
| WD MI20200079 7-24-20.pdf | ||
| Contractor EMR Certification Form 2020.docx | DOCX document | |
| 515-18-109 Bid Drawings - Signed_Part1.pdf | ||
| 515-18-109 Bid Drawings - Signed_Part2.pdf | ||
| 515-18-109 Bid Drawings - Signed_Part3.pdf | ||
| S02 - RFI Form 515-18-109.docx | DOCX document | |
| 515-18-109 Bid Specifications_Part1.pdf | ||
| 515-18-109 Bid Specifications_Part2.pdf | ||
| 36C25020B0058.docx | DOCX document | |
| 515-18-109 Bid Drawings - Signed_Part6.pdf | ||
| 515-18-109 Bid Drawings - Signed_Part4.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
H
J
L
M
M.4
N
M.1
13.3
A
B
C
DD
3.8 4.9 5.3 5.7 6.5 10.6 10.8 11.3 11.8 11.9 13.2
EE
HH
FF
JJ
GG
KK
1 2 3 4 5 6
8 9
11 12 13 14 15
MP402
MP401
MP402
MP403
MP404
AREA NOT IN SCOPE
1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE
DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH
THE COR.
2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING
BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.
CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING
FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH
COORDINATION WITH ALL TRADES IS ESSENTIAL.
3. REFER TO SHEET M-001 FOR GENERAL NOTES AND
ABBREVIATIONS.
4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE
WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH
HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.
5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS
NOTED OTHERWISE.
6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES
WITH STRUCTURE AND OTHER TRADES. NOT ALL
REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE
INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING
CONDITIONS AND ALL TRADES.
7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED
WALLS, TEMPORARY PARTITIONS, AND PHASING.
8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC
ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE
WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS
AND INSTRUCTIONS. GOVERNMENT'S PREFER ROUTING IS
SHOWN - IF THE ROUTING MUST DIFFER FROM THE
PROPOSED, COORDINATE WITH A/E & GOVERNMENT.
COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,
AND WITH NEW CONSTRUCTION ELEMENTS.
NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e
\R e v it \1
M
C
E N
T R
A L p e la y y a n .r v t
/1
/2
:4
:5
P
M
MP101
PIPING PLAN GROUND FLOOR
COMPOSITE
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/20 MAP PME
100% BID DOCUMENTS
PART. SPRINKLERED
100% BID DOCUMENTS
SCALE:
NORTH
3/32" = 1'-0"
PIPING PLAN GROUND FLOOR COMPOSITE
SCALE:
NORTH
1" = 50'-0"
KEY PLAN - GROUND FLOOR
Revisions: Date:
J
L
M
M.4
N
M.1
HH
JJ
GG
KK
1 2 3 4 5 6 7 8
VAV-11
VAV-07
VAV-08
VAV-12
VAV-05
VAV-04
VAV-06
VAV-09
VAV-10
VAV-03
VAV-02
VAV-01
3/4"ø HWR 3/4"ø HWS
3/4"ø HWR
3/4"ø HWS
3/4"ø HWR
3/4"ø HWS
3/4"ø HWS
3/4"ø HWR
3/4"ø HWR
3/4"ø HWS
3/4"ø HWR
3/4"ø HWS
3/4"ø HWR 3/4"ø HWS
3/4"ø HWR
3/4"ø HWS
3/4"ø HWR 3/4"ø HWS
1"ø HWS
1"ø HWR
3/4"ø HWS 3/4"ø HWR
3/4"ø HWS
3/4"ø HWR
3/4"ø HWR
3/4"ø HWS
1"ø HWS
1"ø HWR 1"ø HWS
1"ø HWR
1 1/2"ø HWS
1 1/2"ø HWR
(E) 3/4"ø PC
(E) 2"ø LPS
(E) 3"ø CHWR
(E) 3"ø HWS
(E) 3"ø CHWS
(E) 3"ø HWR
(E) 1"ø HWR
(E) 1"ø HWS
3/4"ø HWR 3/4"ø HWS
1"ø HWS 1"ø HWR
CONNECT TO
40 PSI STEAM
MAIN
SHUT-OFF
VALVE (TYP)
RELOCATE EXISTING
STRAINER, VALVES
AND CONTROLLER
MH401
AREA NOT IN SCOPE
1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE
DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH
THE COR.
2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING
BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.
CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING
FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH
COORDINATION WITH ALL TRADES IS ESSENTIAL.
3. REFER TO SHEET M-001 FOR GENERAL NOTES AND
ABBREVIATIONS.
4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE
WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH
HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.
5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS
NOTED OTHERWISE.
6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES
WITH STRUCTURE AND OTHER TRADES. NOT ALL
REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE
INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING
CONDITIONS AND ALL TRADES.
7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED
WALLS, TEMPORARY PARTITIONS, AND PHASING.
8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC
ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE
WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS
AND INSTRUCTIONS. GOVERNMENT'S PREFERRED
ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM
THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.
COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,
AND WITH NEW CONSTRUCTION ELEMENTS.
NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e
\R e v it \1
M
C
E N
T R
A L p e la y y a n .r v t
/1
/2
:4
:0
P
M
MP401
PIPING LARGE SCALE VIEW -
PHARMACY
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/20 MAP PME
100% BID DOCUMENTS
PART. SPRINKLERED
100% BID DOCUMENTS
SCALE:
MP101
1/4" = 1'-0"
1 PIPING PLAN GROUND FLOOR - PHARMACY
SCALE:
NORTH
1" = 50'-0"
KEY PLAN - PHARMACY
B
C
DD
3.8 4.9 5.3 5.7
6.5
EE
FF
GG
1 2 3 4 5 6
7 8
VAV-13
VAV-14
VAV-15
VAV-17
VAV-16
3/4"ø HWR
3/4"ø HWS 3/4"ø HWS 3/4"ø HWR
(E) PIPING AND CONDUIT TO
BE REWORKED IN THIS AREA
TO COORDINATE WITH NEW
DUCT AND UTILITIES; COORD
WITH ALL TRADES PRIOR TO
START OF WORK
NOTE 8
ROUTE LINES DOWN
EXTERIOR OF WALL,
COORDINATE WITH
EXISTING WINDOW
LOCATIONS, SEE
NOTE 8
ACU-02-EVAP
ROUTE PUMPED
CONDENSATE FROM
EVAPORATOR TO NEARBY
HOUSEKEEPING CLOSET
ROUTE REFG LINES IN
CEILING SPACE, COORD W/
ALL TRADES, SEE NOTE 8
ACU-02-COND
A
7 8 9 10
1 1/4"ø HWR
1 1/4"ø HWS
CUH-01
(E) 3/4"ø HWS
(E) 3/4"ø HWR
(E) 3/4"ø HWS
(E) 3/4"ø HWR
UP
UP
AREA NOT IN SCOPE
1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE
DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH
THE COR.
2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING
BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.
CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING
FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH
COORDINATION WITH ALL TRADES IS ESSENTIAL.
3. REFER TO SHEET M-001 FOR GENERAL NOTES AND
ABBREVIATIONS.
4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE
WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH
HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.
5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS
NOTED OTHERWISE.
6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES
WITH STRUCTURE AND OTHER TRADES. NOT ALL
REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE
INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING
CONDITIONS AND ALL TRADES.
7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED
WALLS, TEMPORARY PARTITIONS, AND PHASING.
8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC
ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE
WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS
AND INSTRUCTIONS. GOVERNMENT'S PREFERRED
ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM
THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.
COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,
AND WITH NEW CONSTRUCTION ELEMENTS.
NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e
\R e v it \1
M
C
E N
T R
A L p e la y y a n .r v t
/1
/2
:4
:1
P
M
MP402
PIPING LARGE SCALE VIEW -
WAITING AND ENTRANCE
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/20 MAP PME
100% BID DOCUMENTS
PART. SPRINKLERED
100% BID DOCUMENTS
SCALE:
MP101
1/4" = 1'-0"
1 PIPING PLAN GROUND FLOOR - PHARMACY WAITING
SCALE:
MP101
1/4" = 1'-0"
2 PIPING PLAN GROUND FLOOR - SOUTH ENTRANCE
SCALE:
NORTH
1" = 50'-0"
KEY PLAN - WAITING AND ENTRANCE
KEYNOTES
MOUNT ON WALL, INSTALL PER MANUFACTURER'S
INSTRUCTIONS. REFER TO DETAIL ON AS502.
COORDINATE WITH ARCH FOR PENETRATIONS THROUGH
EXTERIOR WALL, SEAL PENETRATIONS WATERTIGHT.
L
M
M.4
N
M.1
13.3
HH
JJ
GG
KK
8 9 10 11 12 13 14 15
MH403
VAV-22
VAV-21
VAV-23
VAV-25
VAV-20
VAV-19
VAV-18
3/4"ø HWS
3/4"ø HWR
1"ø HWR
1"ø HWS
1"ø HWS
1"ø HWR
3/4"ø HWR
3/4"ø HWS
1"ø HWS
1"ø HWR
2"ø HWR
2"ø HWS
1"ø HWR 1"ø HWS 1"ø HWR
1"ø HWS
(E) 3/4"ø HWR
(E) 3/4"ø HWS
(E) 3/4"ø SC
(E) 2"ø LPS
(E) 3"ø CHWS
(E) 3"ø CHWR
(E) 3"ø HWS
(E) 3"ø HWR
2"ø MPS
2"ø MPS
RELOCATE EXISTING
STRAINER, VALVES AND
CONTROLLER
3/4"ø HWS 3/4"ø HWR
SHUT-OFF
VALVE (TYP)
RELOCATED
PIPING &
VALVES
AREA NOT IN SCOPE
1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE
DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH
THE COR.
2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING
BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.
CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING
FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH
COORDINATION WITH ALL TRADES IS ESSENTIAL.
3. REFER TO SHEET M-001 FOR GENERAL NOTES AND
ABBREVIATIONS.
4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE
WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH
HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.
5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS
NOTED OTHERWISE.
6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES
WITH STRUCTURE AND OTHER TRADES. NOT ALL
REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE
INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING
CONDITIONS AND ALL TRADES.
7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED
WALLS, TEMPORARY PARTITIONS, AND PHASING.
8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC
ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE
WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS
AND INSTRUCTIONS. GOVERNMENT'S PREFERRED
ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM
THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.
COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,
AND WITH NEW CONSTRUCTION ELEMENTS.
NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e
\R e v it \1
M
C
E N
T R
A L p e la y y a n .r v t
/1
/2
:4
:2
P
M
MP403
PIPING LARGE SCALE VIEW - OPEN
OFFICE AND AUDIOLOGY
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/20 MAP PME
100% BID DOCUMENTS
PART. SPRINKLERED
100% BID DOCUMENTS
SCALE:
MP101
1/4" = 1'-0"
1 PIPING PLAN GROUND FLOOR - OPEN OFFICE AND AUDIOLOGY SCALE:
NORTH
1" = 50'-0"
KEY PLAN - OPEN OFFICE AND AUDIOLOGY
13.3
A
B
C
DD
10.6 10.8 11.3 11.8 11.9 13.2
EE
FF
GG
8 9 10
11 12 13
14 15
VAV-24
VAV-37
VAV-38
VAV-36
CUH-02
VAV-35
VAV-34
DCP-01
VAV-33
VAV-32
VAV-31
VAV-28
VAV-26
VAV-27
VAV-29
1 1/4"ø HWR
1 1/4"ø HWS
(E) 3/4"ø HWR
(E) 3/4"ø HWS
1"ø HWR
1"ø HWS 1"ø HWR
1"ø HWR
1"ø HWS 3/4"ø HWS
3/4"ø HWR
3/4"ø HWS 3/4"ø HWR
3/4"ø HWR
3/4"ø HWS
PRESSURE POWERED
CONDENSATE PUMPS:
DUPLEX WITH RECEIVER, 4,000
LB/HR CAPACITY, BACKPRESSURE
15 PSI, MOTIVE PRESSURE 40 PSI
3/4"ø SC
3/4"ø SC
ROUTE STM COND PREVIOUSLY
RETURN TO COND PUMP IN
THIS LOCATION TO PUMP
DCP-01
ROUTE STM COND PREVIOUSLY
RETURN TO COND PUMP IN
THIS LOCATION TO PUMP
DCP-01
2"ø MPS
SHUT-OFF
VALVE (TYP)
ACU-01-EVAP
3/4"ø HWS
3/4"ø HWR
3/4"ø HWS
3/4"ø HWR
1"ø HWS
1"ø HWR
1"ø HWS
VAV-30
ROUTE PUMPED
CONDENSATE FROM
EVAPORATOR TO FLOOR
DRAIN IN NEARBY
MECHANICAL CLOSET
ROUTE REFG LINES IN
CEILING SPACE,
COORD W/ ALL
TRADES, SEE NOTE 8
ACU-01-COND
ROUTE LINES DOWN
EXTERIOR OF WALL,
COORDINATE WITH
EXISTING WINDOW
LOCATIONS, SEE NOTE 8
AREA NOT IN SCOPE
1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE
DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH
THE COR.
2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING
BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.
CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING
FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH
COORDINATION WITH ALL TRADES IS ESSENTIAL.
3. REFER TO SHEET M-001 FOR GENERAL NOTES AND
ABBREVIATIONS.
4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE
WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH
HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.
5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS
NOTED OTHERWISE.
6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES
WITH STRUCTURE AND OTHER TRADES. NOT ALL
REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE
INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING
CONDITIONS AND ALL TRADES.
7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED
WALLS, TEMPORARY PARTITIONS, AND PHASING.
8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC
ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE
WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS
AND INSTRUCTIONS. GOVERNMENT'S PREFERRED
ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM
THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.
COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,
AND WITH NEW CONSTRUCTION ELEMENTS.
NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e
\R e v it \1
M
C
E N
T R
A L p e la y y a n .r v t
/1
/2
:4
:4
P
M
MP404
PIPING LARGE SCALE VIEW -
URGENT CARE
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/20 MAP PME
100% BID DOCUMENTS
PART. SPRINKLERED
100% BID DOCUMENTS
SCALE:
MP101
1/4" = 1'-0"
1 PIPING PLAN GROUND FLOOR - UREGENT CARE
SCALE:
NORTH
1" = 50'-0"
KEY PLAN - URGENT CARE
AIR FLOW
THERMOMETER (TYP)
PRESSURE AND
TEMPERATURE TEST
PLUG (TYP)
MANUAL AIR VENT
HEATING COIL
CONTROL VALVE
FLOW MEASURING DEVICE
BALANCING VALVE
WITH MEMORY STOP
(SEE SPECS FOR VALVE
DETAILS)
HWR
SHUT-OFF VALVE
HWS
UNION (TYP)
DRAIN VALVE WITH
HOSE END
CONNECTION
SHUT-OFF VALVE
STEAM, GAS, OR AIR PIPING
BRANCH SECTIONALIZING
VALVE, OR EQUIPMENT
SHUT-OFF VALVE
SUPPLY MAIN
BRANCH PIPING
OFF TOP OF MAIN
WATER PIPING
BRANCH SECTIONALIZING
VALVE, OR EQUIPMENT
SHUT-OFF VALVE
SUPPLY OR
RETURN MAIN
BRANCH PIPING OFF
BOTTOM OF MAIN
NOTE: BRANCHES MAY BE 45 OR 90 DEGREES ABOVE/BELOW MAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e
\R e v it \1
M
C
E N
T R
A L p e la y y a n .r v t
/1
/2
:4
:4
P
M
MP501
PIPING DETAILS RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/20 MAP PME
100% BID DOCUMENTS
PART. SPRINKLERED
100% BID DOCUMENTS
NOT TO SCALE
HOT WATER HEATING COIL PIPING DIAGRAM
NOT TO SCALE
PIPING BRANCH CONNECTIONS
J J
PANEL;CIRCUIT
D
DT
K
KP
LV
LM
MC
P
T
WP
PS
XP
HP
D
OS OS
CONDUIT UP
GROUND ROD
CONDUIT HOME RUN TO PANEL
CONDUIT RUN
UNDERGROUND GROUND WIRE
UNDERGROUND TELECOMMUNICATIONS CONDUIT / DUCT BANK
UNDERGROUND ELECTRICAL CONDUIT / DUCT BANK
JUNCTION BOX
WEATHERPROOF SWITCH
TIMER SWITCH
VACANCY SENSOR SWITCH
LOW VOLTAGE MASTER SWITCH
LOW VOLTAGE SWITCH
KEY OPERATED W/ PILOT LIGHT SWITCH
THREE-WAY SWITCH
DOUBLE POLE SWITCH
SINGLE POLE TOGGLE SWITCH
KEY OPERATED SWITCH
MOMENTARY CONTACT SWITCH
SINGLE POLE/DOUBLE THROW SWITCH
FOUR-WAY SWITCH
DIMMING MASTER CONTROL
MOTORIZED PROJECTION SCREEN SWITCH
EXPLOSION-PROOF SWITCH
DIMMER SWITCH
HORSEPOWER RATED SWITCH
VACANCY/OCCUPANCY SENSOR -
WALL / CEILING MOUNTED
POLE MOUNTED FIXTURE - DOUBLE HEAD
POLE MOUNTED FIXTURE - SINGLE HEAD
PULL BOX
GROUND TEST WELL
LIGHTNING PROTECTION COPPER DOWN CONDUCTOR
CADWELD CABLE CONNECTION
AIR TERMINAL
GROUND BUS
PB
LIGHTNING PROTECTION /
GROUNDING SYMBOL LIST
WIRING SYMBOL LIST
POWER SYMBOL LIST
LIGHTING SYMBOL LIST
SWITCHING SYMBOL LIST
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
G
T
E
GFR
CAPACITOR
VALUE AS
INDICATED ON
DRAWINGS
V
G
A
SINGLE LINE DIAGRAM SYMBOL LIST
CONTACTOR - NORMALLY OPEN
CONTACTOR - NORMALLY CLOSED
LINE TERMINATOR
ELECTRICAL CONNECTOR
GROUND
FUSE
DISCONNECT SWITCH
TRANSFORMER
JAGGED RESISTOR
VOLTAGE REGULATOR
3-PHASE MOTOR
WYE CONNECTION
SERVICE WEATHERHEAD
METER
CONTROL TRANSFORMER
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
CABLE POT HEAD
CIRCUIT BREAKER
DELTA CONNECTION
BATTERY
SURGE ARRESTOR
DRAW OUT, LOW VOLTAGE CIRCUIT BREAKER
GROUND FAULT RELAY
AUTOMATIC TRANSFER SWITCH
H.R.C FUSE RATING AS INDICATED ON
DRAWING
RATINGS AS INDICATED ON DRAWING
H.R.C FUSED CUT-OUT
SURGE PROTECTION DEVICE
LIGHTNING ARRESTOR
POWER FACTOR CORRECTION CAPACITOR BANK
POTENTIAL TRANSFORMER WITH PRIMARY
AND SECONDARY FUSES
FULL VOLTAGE NON-REVERSIBLE MOTOR
STARTER AND OVERLOAD RELAY,
MOUNTED IN MOTOR CONTROL CENTER
REDUCED VOLTAGE (STAR/DELTA) NON-
REVERSIBLE MOTOR STARTER AND OVERLOAD
RELAY, MOUNTED IN MOTOR CONTROL CENTER
OVERLOAD RELAY
KEY INTERLOCK
AMMETER, VOLTMETER
AMMETER, VOLTMETER SELECTOR SWITCH
INDICATOR LAMP
STAND-BY DIESEL GENERATOR SET
COMBINATION POWER MONITORING SYSTEM,
PROGRAMMING AND DISPLAY
ADDRESSABLE ELECTRONIC MODULE
DRAW OUT, MEDIUM VOLTAGE VACUUM
CIRCUIT BREAKER (VCB)
M
SPD
ASS VSS
K
AEM
ELECTRICAL BUS DUCT WITH FUSIBLE BUS PLUGS
BAT
PC
C
EMERGENCY LIGHTING FIXTURE - CEILING MOUNTED
LIGHTING FIXTURE - CEILING SURFACE MOUNTED
LIGHTING FIXTURE - CEILING / PENDANT / WALL MOUNTED
LINEAR WALL WASHER LIGHTING FIXTURE - CEILING / PENDANT MOUNTED
SPOT LIGHT FIXTURE
TRACK LIGHTING, LENGTH AND NUMBER OF FIXTURES AS INDICATED ON DRAWINGS
INDUSTRIAL LIGHTING FIXTURE - CEILING / WALL MOUNTED
EXIT SIGN - CEILING / WALL MOUNTED, HATCH INDICATES NUMBER OF
FACES, ARROWS AS INDICATED ON PLANS
BATTERY OPERATED EMERGENCY LIGHTING UNIT - CEILING / WALL MOUNT
SINGLE REMOTE HEAD EMERGENCY LIGHTING UNIT - CEILING / WALL MOUNT
DUAL REMOTE HEAD EMERGENCY LIGHTING UNIT - CEILING / WALL MOUNT
EMERGENCY LIGHTING UNIT BATTERY
REEL LIGHT
PHOTO CELL
LIGHTING CONTACTOR
LIGHTING FIXTURE - PENDANT / WALL MOUNTED
POLE MOUNTED FIXTURE - THREE HEAD
POLE MOUNTED FIXTURE - FOUR HEAD
STATIC GROUNDING RECEPTACLEG
HOT
CONDUCTOR
GROUND
CONDUCTOR
NEUTRAL
CONDUCTOR
SHUNT TRIPST
PM
1-PHASE MOTOR
EXISTING
NEW
LINETYPE LEGEND
OS OCCUPANCY SENSOR SWITCHS
INSTANTANEOUS OVER CURRENT
OR RATE OF RISE RELAY
TIME PHASE OVER CURRENT RELAY
GROUND INSTANTANEOUS AND TIME
OVER CURRENT RELAY
50N/51N
ANSI RELAY DESIGNATIONS
POWER FACTOR RELAY55
UNDERVOLTAGE RELAY27
OVERVOLTAGE RELAY59
FREQUENCY RELAY81
86 LOCKOUT RELAY
DIFFERENTIAL PROTECTION RELAY87
DEMOLITION
CONDUIT DOWN
FIXED CAPACITOR
RL
EMERGENCY LIGHTING FIXTURE - PENDANT / WALL MOUNTED
EMERGENCY LIGHTING FIXTURE - CEILING / PENDANT / WALL MOUNTED
LIGHTING FIXTURE IDENTIFIERS (REFER TO LIGHTING FIXTURE SCHEDULE):
"C" COMPACT FLUORESCENT TYPE
"F" FLUORESCENT LIGHTING FIXTURE TYPE
"H" HID LIGHTING FIXTURE TYPE
"L" LED LIGHTING FIXTURE TYPE
"S" SITE LIGHTING FIXTURE TYPE
"T" TRACK LIGHTING FIXTURE TYPE
"X" EXIT SIGN FIXTURE TYPE
"EM" EMERGENCY LIGHTING FIXTURE TYPE
"NL" NIGHT LIGHT FIXTURE TYPE
"+ X' - X" (or XXXXMM) AFF" LIGHT FIXTURE MOUNTING HEIGHT ABOVE FINISHED FLOOR
TH THERMAL OVERLOAD SWITCHS
WALL WASHER LIGHTING FIXTURE - CEILING / PENDANT MOUNTED
EMERGENCY INDUSTRIAL LIGHTING FIXTURE - CEILING / WALL MOUNTED
ELECTRICAL EQUIPMENT DESIGNATION LEGEND
EQUIPMENT SEQUENCE NUMBER
01, 02, 03, etc.
LEVEL
0 LEVEL G (GROUND FLOOR)
1 LEVEL 1 (FIRST FLOOR)
2 LEVEL 2 (SECOND FLOOR)
R LEVEL R (ROOF)
EQUIPMENT ABBREVIATIONS
ATS AUTOMATIC TRANSFER SWITCH
BAT BATTERY
BTC BATTERY CHARGER
CAP CAPACITOR BANK
CBS CENTRAL BATTERY INVERTER SYSTEM
DCP 28V DC PANEL
DP DISTRIBUTION PANEL
ECAP CAPACITOR BANK FED FROM EMERGENCY SWB
EDP EMERGENCY DISTRIBUTION PANEL STANDBY GENERATOR POWER
ELP EMERGENCY LIGHTING PANEL STANDBY GENERATOR POWER
EMLP EMERGENCY LIGHTING PANEL BATTERY POWER
ERP EMERGENCY RECEPTACLE PANEL STANDBY GENERATOR POWER
ESDP EMERGENCY SUB-DISTRIBUTION PANEL STANDBY GENERATOR
POWER
ESWB EMERGENCY LOW VOLTAGE SWITCHBOARD
FP FEEDER PILLAR
GEN GENERATOR
GPU 400Hz GROUND POWER UNIT
LB LOAD BANK
LP LIGHTING PANEL NORMAL POWER
LRP LIGHTING RELAY PANEL
MCC LOW VOLTAGE MOTOR CONTROL CENTER
SWB LOW VOLTAGE SWITCHBOARD
MPSWG MEDIUM VOLTAGE PARALLELING SWITCHGEAR
MSWG MEDIUM VOLTAGE SWITCHGEAR
PIT POP-UP UTILITY PIT
RP RECEPTACLE PANEL
SDP SUB-DISTRIBUTION PANEL
TR DRY-TYPE TRANSFORMER
ULP LIGHTING PANEL UPS POWER
UPS UNINTERRUPTIBLE POWER SUPPLY
URP RECEPTACLE PANEL UPS POWER
VFD VARIABLE FREQUENCY DRIVE
XXXX - X XX
UNDERGROUND ELECTRICAL CONDUIT
CABLE TRAY (TYPE AND SIZE INDICATED ON DRAWINGS)
CABLE TRAY UP OR DOWN OR SECTION CUT
DL DAYLIGHT SENSOR
LIGHTING FIXTURE - CEILING RECESSED
SWITCH W/ PILOT LIGHT
VSS
VS VS
EMERGENCY LIGHTING FIXTURE - CEILING
RECESSED
SINGLE RECEPTACLE - WALL, HORIZONTAL, ABOVE COUNTER,
EMERGENCY, FULLY CONTROLLED, CEILING, FLOOR
RECEPTACLE, 220V, 3 PHASE - SINGLE, DUPLEX
RECEPTACLE, 240/208V, 3 PHASE - WALL, FLOOR
RECEPTACLE, 480V, 3 PHASE - WALL, FLOOR
POWER POLE
ELECTRICAL EQUIPMENT - TYPE OF EQUIPMENT AS INDICATED
RECESSED ELECTRICAL PANEL
SURFACE MOUNTED ELECTRICAL PANEL
CONTROL PANEL
DOOR CONTROL PANEL
COMBINATION DISCONNECT SWITCH / MOTOR STARTER
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
1-PHASE MOTOR, "X" DENOTES HORSE POWER
MOTOR STARTER
VARIABLE FREQUENCY DRIVE
PUSHBUTTON - 2 BUTTON, W/ PILOT LIGHT
PUSHBUTTON - 3 BUTTON, W/ PILOT LIGHT
PUSHBUTTON - EMERGENCY OFF
ELECTRICAL BUS DUCT W/ FUSIBLE BUS PLUGS
UTILITY METER
CABLE TRAY
PUSHBUTTON - 1 BUTTON, W/ PILOT LIGHT
RECEPTACLE, 240/208V, 3 PHASE, W/DISCONNECT - FUSED,
W/DISCONNECT - NON-FUSED - WALL
RECEPTACLE, 480V, 3 PHASE, W/DISCONNECT - FUSED,
W/DISCONNECT - NON-FUSED - WALL
MANUAL MOTOR STARTER
C
C
DUPLEX RECEPTACLE - WALL, HORIZONTAL, ABOVE COUNTER, HOSPITAL
GRADE, EMERGENCY, FULLY CONTROLLED, HALF CONTROLLED, HOSPITAL
GRADE EMERGENCY, CEILING, FLOOR
QUADPLEX RECEPTACLE - WALL, HORIZONTAL, ABOVE COUNTER, HOSPITAL
GRADE, EMERGENCY, FULLY CONTROLLED, HALF CONTROLLED, HOSPITAL
GRADE EMERGENCY, CEILING, FLOOR
C
X
3-PHASE MOTOR, "X" DENOTES HORSE POWERX
RECEPTACLE IDENTIFIERS:
"GFCI" GROUND FAULT CIRCUIT INTERRUPTER
"IG" ISOLATED GROUND
"PT" POKE THRU
"WP" WEATHERPROOF
"TP" TAMPER PROOF
"XP" EXPLOSION PROOF
"USB" UNIVERSAL SERIAL BUS OUTLET.
M
CPCP
DCPDCP
VFDVFD
PP
D THREE WAY-DIMMER SWITCHS3
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
(ALL MAY NOT APPLY)
CENTERLINE
SWITCH
WIREMOLD
COUNTER
VOICE/DATA POWER
CENTERLINE
POWER VOICE/DATA
CENTERLINE
THERMOSTAT
CARD READER
SWITCH
2'
(MIN.) 4'3'-10" 3'-8"
6' 6'-8"
3'-10" 3'-10"
OR PER
PROJECTCODE
REQUIREMENTS
HIGHEST
DISCONNECT
/ BREAKER
BACKSPLASH
(WHERE
PRESENT)
MAXIMUM
HEIGHT
OPERATING
CONTROLS
NURSE CALL
CONTROLS
FIRE ALARM
AUDIBLE
VISUAL
STROBE
FIRE ALARM
PULL BOX
TYPICAL
AREA
HAZARDOUS
AREAS
OUTLETS
UNFINISHED
AREAS
SWITCHES &
CONTROLS
WALL MOUNTED
TELEPHONE
ELECTRIC
PANEL
DEVICES OVER
COUNTERS
FINISHED
FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:0
P
M
EO000
ELECTRICAL SYMBOL LIST RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
NOT TO SCALE
MOUNTING HEIGHTS
187216
NOTE:
MOUNTING HEIGHT OF NEW FIRE ALARM DEVICES SHALL
MATCH EXISTING.
100% BID DOCUMENTS
1. DRAWINGS ARE DIAGRAMMATIC AND INDICATE DESIGN INTENT.
2. DO NOT SCALE DRAWINGS.
3. FIELD-VERIFY EXISTING CONDITIONS AND ACTUAL DIMENSIONS PRIOR TO START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH OTHER TRADES TO AVOID PHYSICAL CONFLICTS AND CONFLICTS WITH
WORK SEQUENCE.
5. REFER TO ARCHITECTURAL DRAWINGS FOR WALLS WITH SPECIAL WALL FINISHES. COORDINATE OVERALL WALL
COVERING THICKNESS AND PROVIDE PLASTER RING WITH APPROPRIATE DEPTH.
6. REFER TO ONE-LINE OR RISER DIAGRAM FOR CONDUIT AND FEEDER SIZES.
7. BRANCH WIRING SHALL BE SIZED PER THE SCHEDULES, UNLESS OTHERWISE NOTED, DERATING OF WIRE HAS BEEN INCORPORATED INTO SIZES SHOWN ON SCHEDULES. ADDITIONAL DERATING, IF NECESSARY, SHALL COMPLY WITH NEC SECTION 310.15. DUE TO HARMONIC LOADING, THE NEUTRAL CONDUCTOR SHALL BE CONSIDERED AS
CURRENT CARRYING CONDUCTOR FOR DERATING PURPOSES.
8. CONDUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC ARTICLE 250.
9. CONDUIT AND WIRING SHALL BE CONCEALED IN WALL OR CEILING CAVITY EXCEPT FOR EXISTING BLOCK WALLS AND AREAS WITH EXPOSED CEILING CONSTRUCTION. AREAS WITH NEW WALLS OR RECONSTRUCTED WALLS SHALL HAVE CONDUIT AND WIRING CONCEALED IN WALL CAVITY. EXPOSED CONDUIT IN LOW AND HIGH BAY STORAGE, MANUFACTURING, ASSMEBLY, MAINTENANCE, AND SHIPPING AND RECEIVING AREAS SHALL BE RGS (RIGID GALVANIZED STEEL) UP TO 10 FT HEIGHT ABOVE FINISHED FLOOR, WHERE MOUNTED EXPOSED AND
SUBJECT TO DAMAGE.
10. MAIN BRANCH CIRCUIT CONDUIT RUNS SHALL BE EMT, UNLESS NOTED OTHERWISE. FLEXIBLE CONDUIT OR MC CABLE MAY BE USED FOR FINAL RUN TO POWER POLE (MAXIMUM OF 10 FEET LENGTH). REFER TO SPECIFICATIONS
FOR ADDITIONAL RACEWAY RESTRICTIONS.
11. TYPE MC CABLE SHALL BE CONCEALED IN WALL AND CEILING SPACES WITH ACCESSIBLE CEILING ONLY. REFER TO
SPECIFICATIONS FOR ADDITIONAL RACEWAY RESTRICTIONS.
12. WHERE GFCI PROTECTION IS INDICATED, A GFCI TYPE RECEPTACLE SHALL BE PROVIDED AT EACH LOCATION.
LOAD SIDE PROTECTION OF DOWN STREAM DEVICES IS NOT ACCEPTABLE.
13. RECEPTACLES WITHIN 6 FEET OF SINKS AND ALL OTHER WASH BASINS SHALL BE GFCI.
14. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE POWER FEED(S) TO MECHANICAL EQUIPMENT THAT REQUIRES A POWER FEED, UNLESS OTHERWISE NOTED. COORDINATE WITH INFORMATION ON MECHANICAL
DRAWINGS AND MECHANICAL TRADES ON SITE.
15. REFER TO ARCHITECTURAL DRAWINGS FOR WALLS TO BE PROVIDED WITH INSULATION FOR ACOUSTICAL
PURPOSES.
16. FIRE-STOPPING MATERIAL SHALL BE PROVIDED FOR RACEWAY PENETRATIONS THROUGH FIRE-RATED WALLS OR
ASSEMBLIES.
17. EMPTY CONDUITS SHALL BE DEBURRED, CLEANED, TAGGED AND PROVIDED WITH A NYLON PULL STRING.
18. IN AREAS WITH GYPSUM BOARD CEILINGS, THE ELECTRICAL TRADES SHALL ROUTE CONDUIT AND POSITION PULL/JUNCTION BOXES TO ALLOW ACCESS THRU ACCESS PANELS PROVIDED BY ARCHITECTURAL TRADES, WHERE POSSIBLE. WHERE ADDITIONAL ACCESS PANELS ARE REQUIRED FOR ELECTRICAL EQUIPMENT, THE ELECTRICAL TRADES SHALL INCLUDE THE ACCESS PANEL IN THE BID. ACCESS PANEL SHALL BE INSTALLED BY THE CEILING
INSTALLER. ADDITIONAL ACCESS PANEL LOCATIONS SHALL BE APPROVED BY THE ARCHITECT.
19. IN GENERAL, ELECTRICAL DEVICES, WHICH ARE INDICATED ON THE PLAN, MAY BE SCALED AND MOUNTED TO THE NEAREST STUD EXCEPT WHERE DIMENSIONED OR ADDITIONAL LAYOUT CRITERIA IS INDICATED AT CRITICAL
LOCATIONS.
20. ELECTRICAL DEVICE OUTLETS SHALL NOT BE LOCATED BACK TO BACK WITHIN THE SAME STUD SPACE IN INTERIOR
INSULATED WALLS. ONE OF THE DEVICES SHALL BE OFFSET TO THE NEXT STUD SPACE.
21. MULTIGANG DEVICES SHALL BE GANGED UNDER SINGLE MULTIGANG COVERPLATE.
22. WHERE ELECTRICAL DEVICES ARE INDICATED ON A COLUMN, THE DEVICE SHALL BE CENTERED ON THE COLUMN
SURFACE.
23. FURNITURE LAYOUTS ARE SHOWN FOR REFERENCE ONLY. COORDINATE FINAL LOCATION OF ELECTRICAL DEVICES, FLOOR BOXES, AND FLOOR CORES WITH FINAL FURNITURE LAYOUT PRIOR TO INSTALLATION.
24. WHERE POWERED FURNITURE SYSTEMS ARE INDICATED TO BE POWERED FROM COLUMN OR HARD WALL, THE ELECTRICAL TRADES SHALL PROVIDE A BLANK COVER WITH CENTER HOLE FOR CONNECTION AND TERMINATION TO THE FURNITURE SYSTEM WHIP. FURNITURE SYSTEM WHIP, CONNECTOR AND WIRING TO FURNITURE SYSTEM WILL BE FURNISHED BY FURNITURE INSTALLER. COORDINATE EXACT TERMINATION POINT WITH THE FURNITURE SUPPLIER. COORDINATE THE PHASING/CIRCUITING AS INDICATED ON THE ELECTRICAL DRAWINGS WITH THE
FURNITURE INSTALLER FOR CONFIGURATION CONSISTENT WITH THE DESIGN INTENT.
25. WHERE POWERED FURNITURE SYSTEMS ARE INDICATED TO BE POWERED FROM POWER POLES, THE ELECTRICAL TRADES SHALL PROVIDE A JUNCTION BOX ABOVE CEILING NEAR THE TOP OF THE POWER POLE, PROVIDE FLEX CONDUIT TO EXTEND FURNITURE WIRING TO JUNCTION BOX AND PROVIDE TERMINATION TO THE FURNITURE SYSTEM CABLING. FURNITURE SYSTEM POWER POLE, CONNECTOR AND WIRING TO FURNITURE SYSTEM WILL BE FURNISHED BY FURNITURE INSTALLER. COORDINATE EXACT TERMINATION POINT WITH THE FURNITURE SUPPLIER.
COORDINATE THE PHASING/CIRCUITING AS INDICATED ON THE ELECTRICAL DRAWINGS WITH THE FURNITURE
INSTALLER FOR CONFIGURATION CONSISTENT WITH THE DESIGN CONTENT.
26. ASSUMPTIONS OF FURNITURE SYSTEM (BY OTHERS) ARE AS FOLLOWS:
A. FURNITURE IS 5 WIRE TYPE (L1, L2, L3, N & G).
B. CUBICLE FURNITURE, POWER POLES AND FURNITURE WHIPS ARE TO BE FURNISHED BY OTHERS.
C. FURNITURE SHALL UTILIZE FREE-STANDING POWER POLES WITH WHIPS TO FURNITURE CONNECTION WHERE
INDICATED ON DRAWINGS.
D. FURNITURE SHALL UTILIZE POWER POLES WHICH ARE INTEGRAL WITH FURNITURE WALLS (TEE OF CORNERS)
WHERE INDICATED ON DRAWINGS.
E. TERMINATION OF WHIP AT BOTTOM OF POWER POLE, CONNECTION OF WHIP TO FURNITURE RAIL WILL BE BY
ELECTRICAL CONTRACTOR.
27. EMERGENCY (NEC SECTION 700) WIRING SHALL BE IN SEPARATE CONDUIT FROM NON-EMERGENCY WIRING
(EXCEPT AT FINAL CONNECTION TO LIGHT FIXTURES).
28. EACH 120 VOLT BRANCH CIRCUIT PHASE CONDUCTOR SHALL BE PROVIDED WITH SEPARATE FULL SIZE NEUTRAL
CONDUCTOR.
29. 120 VOLT BRANCH CIRCUITS MAY SHARE FULL SIZE GROUND WITH UP TO 3 CIRCUITS WHICH SERVE SIMILAR LOADS.
30. WHERE ADEQUATE CIRCUIT QUANTITIES ARE NOT AVAILABLE WITHIN A DESIGNATED PANEL, BUT ARE AVAILABLE IN ANOTHER PANEL NEARBY, THE ELECTRICAL CONTRACTOR SHALL REVISE THE CIRCUITS TO THE AVAILABLE PANEL
BOARD AT NO ADDITIONAL COST.
31. PROVIDE FIELD LABELING OF BRANCH CIRCUITS AND RECEPTACLE DEVICES TO INDICATE PANEL BOARD AND
CIRCUIT NUMBER OF SOURCE. PROVIDE LABELING ON DEVICE COVER PLATE OR J-BOX COVER.
32. CONDUCTORS SIZED FOR VOLTAGE DROP THAT ARE TOO LARGE FOR LUGS SHALL BE REDUCED USING EITHER COMPRESSION PIN TERMINALS PIGTAIL ADAPTERS OR MODULAR INSULATED POWER DISTRIBUTION BLOCKS.
33. PANEL BOARD SUPPLIER SHALL PROVIDE A GROUND BAR ASSEMBLY MOUNTED ON A BAKELITE BACKING AND MOUNT TO PANEL IN SUCH A WAY AS TO INSURE AN ISOLATED GROUND CONNECTION FOR CIRCUITS.
34. FEEDER SIZES ARE BASED ON NEC 2014 ARTICLE 310.15, 250.122, AND 110.14. CONDUIT SIZES SELECTED ARE BASED ON RIGID METAL CONDUIT (UNLESS NOTED OTHERWISE) AND 40% CONDUIT FILL. CONDUIT SIZE SHALL BE ADJUSTED AS REQUIRED FOR OTHER TYPES OF CONDUIT. CONDUCTOR SIZE IS BASED ON AN AMBIENT TEMPERATURE OF 60°C AND 600V INSULATED COPPER CABLE APPLIED AT 60°C FOR TERMINATIONS RATED 100 AMPS AND LESS AND 75°C FOR TERMINATIONS RATED MORE THAN 100 AMPS. CONDUCTOR SIZE IS A MINIMUM AND DOES NOT TAKE INTO ACCOUNT VOLTAGE DROP OR DERATING. CONDUCTOR SIZE SHALL BE ADJUSTED AS REQUIRED PER NEC. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR
APPROPRIATE TYPE OF CONDUCTORS AND LUGS FOR ALL MECHANICAL EQUIPMENT.
ELECTRICAL GENERAL NOTES (ALL MAY NOT APPLY)
1. SCOPE OF WORK: ELECTRICAL DEMOLITION WORK SHALL INCLUDE DISCONNECTION OF LIGHTING FIXTURES, RECEPTACLES, WIRING, CONDUIT, BOXES, ETC. IN THE AREA OF NEW AND/OR RENOVATION CONSTRUCTION.
2. SITE SURVEY: ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMISSION OF HIS/HER BID TO EXAMINE
THE EXISTING CONDITIONS AND THE EXTENT OF THE DEMOLITION WORK.
3. SITE UTILITIES: ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REQUESTING EXISTING AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER.
ELECTRICAL CONTRACTOR IS FULLY RESPONSIBLE FOR REPAIRING ALL DAMAGED UTILITIES RESULTING FROM
CONSTRUCTION RELATED ACTIVITIES.
4. COORDINATION WITH OTHER TRADES: EXAMINE ALL DRAWINGS BY OTHER TRADES TO BE FAMILIAR WITH DEMOLITION REQUIREMENTS BY OTHER TRADES. PROVIDE ALL INCIDENTAL ELECTRICAL DEMOLITION OF AND/OR RELOCATION OF ELECTRICAL SYSTEMS TO FACILITATE THE DEMOLITION WORK FROM OTHER TRADES WHETHER
OR NOT INDICATED ON THE DRAWINGS.
5. COORDINATION: COORDINATE THE DEMOLITION WITH THE NEW WORK FOR THE EXTENT OF DEMOLITION WORK.
6. RACEWAYS: REMOVE ALL UNUSED EXPOSED CONDUIT, WIRE, RACEWAY, JUNCTION BOXES, HANGERS, AND CLAMPS BACK TO THE SOURCE PANELBOARDS. WHERE CONDUITS ARE CONCEALED IN WALL CAVITIES, CUT AND REMOVE THE CONDUITS ABOVE EXISTING WALL LEADING INTO AN ACCESSIBLE CEILING OR TRUSS SPACE. REMOVE
SURFACE MOUNTED ELECTRICAL DEVICES, BOXES, AND RELATED CONDUITS.
7. PANEL SCHEDULES: PROVIDE UP-TO-DATE PANEL SCHEDULES FOR ALL PANELS DESIGNATED AS EXISTING TO REMAIN. SHOW ACTIVE CIRCUITS AND LOADS. IDENTIFY CONDUITS AND LABEL CIRCUITS FOR FUTURE
RELOCATION.
8. CONDUIT STATUS: FIELD VERIFY STATUS OF CONDUITS IN THE CEILING SPACE AND DETERMINE IF CONDUITS ARE TO REMAIN OR BE REMOVED. WHERE APPLICABLE AND NOT SPECIFICALLY INDICATED OTHERWISE, EXISTING IN- PLACE CONDUITS ABOVE CEILINGS OR IN WALLS, JUNCTION BOXES, PULL BOXES, AND HANGERS ABOVE CEILINGS, TRUSS SPACE, OR IN WALLS MAY BE RE-USED FOR NEW WIRING. COMPLY WITH CONDUIT FILL REQUIREMENTS
LISTED IN THE NEC.
9. ACTIVE CIRCUITS: EXISTING ACTIVE CIRCUITS IN WORK AREAS TO REMAIN. WHERE REMOVAL OF CONDUIT AND WIRING AFFECTS THE OPERATION UPSTREAM AND/OR DOWNSTREAM OF ELECTRICAL EQUIPMENT, WHICH IS NOT INDICATED TO BE REMOVED, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN AND PROVIDE ALL REQUIRED CONDUITS AND WIRING TO RESTORE THE UPSTREAM AND/OR DOWNSTREAM CONNECTIONS OF ELECTRICAL EQUIPMENT TO ITS NORMAL OPERATION. ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WITH
OWNER AND ASSOCIATED PARTIES.
10. FEEDERS: DISCONNECT AND REMOVE FEEDERS FROM THE ARCHITECTURAL AND MECHANICAL EQUIPMENT TO BE REMOVED. COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS AND CONTRACTORS FOR FULL
SCOPE OF WORK. REMOVE ALL DISCONNECTS, JUNCTION BOXES, AND CONTROL STATIONS.
11. LOW VOLTAGE CABLING: REMOVE UNUSED DATA/COMMUNICATION CONDUITS AND CABLING COMING FROM TELEPHONE AND DATA CLOSETS. CONDUITS THAT ARE EXISTING TO REMAIN SHALL BE TAGGED AS SUCH.
12. SUPPORT: RE-SUPPORT ITEMS WHERE WALLS AND SUPPORTS ARE SCHEDULED FOR REMOVAL.
13. PROTECTION: PROTECT EXISTING ITEMS TO REMAIN FROM DAMAGE BY OTHER DEMOLITION ACTIVITIES.
14. TEMPORARY POWER: FURNISH AND INSTALL TEMPORARY FEEDS FOR EXISTING ITEMS AFFECTED BY
CONSTRUCTION AND REQUIRED TO BE OPERATIONAL DURING THE CONSTRUCTION PERIOD.
15. MATERIAL: MATERIAL INCLUDING, BUT NOT LIMITED TO, WIRING DEVICES, CONDUIT, WIRING, JUNCTION BOXES, ETC.
THAT IS REMOVED SHALL BECOME PROPERTY OF THE VA ELECTRICAL SHOP. THE VA ELECTRICAL SHOP TO INSPECT AND KEEP ANY MATERIAL THAT ARE STILL USABE, PRIOR TO CONTRACTOR DISPOSING OF THESE
MATERIALS.
16. SALVAGED EQUIPMENT: ELECTRICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO, PANELBOARDS, TRANSFORMERS, LIGHT FIXTURES, DISCONNECT SWITCHES, CONTROL PANELS, ETC. THAT IS REMOVED SHALL BE
CLEANED AND RETURNED TO OWNER, UNLESS OWNER ELECTS TO DISPOSE OF THIS EQUIPMENT.
ELECTRICAL GENERAL NOTES (DEMOLITION WORK)
(ALL MAY NOT APPLY)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:0
P
M
EO001
DEMOLITION AND GENERAL
NOTES
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
187216
L
M
M.4
N
M.1
13.3
A
B
13.2
HH
FF
JJ
GG
KK
12 3 4 5 6 7 8 9 10 11 12 13 14 15
ED402
ED403
ED404
ED402
ED401
10.8
TEMPORARY
PHARMACY
(PHASE 1) OPEN
OFFICE AND
AUDIOLOGY
(PHASE 3)
PHARMACY
(PHASE 2)
URGENT CARE
(PHASE 4)
SHADE INDICATES
APPROXIMATE
AREA OUT OF
SCOPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:0
P
M
ED101
DEMOLITION PLAN GROUND
FLOOR
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
SCALE:
NORTH
EP405 3/32" = 1'-0"
1 DEMOLITION PLAN GROUND FLOOR COMPOSITE
GENERAL NOTES :
1. REFER TO SHEET EO000, EO001, EY000 AND FA000 FOR
SYMBOLS, DEMOLITION AND GENERAL NOTES RESPECTIVELY.
187216
NOT TO SCALE
KEY PLAN - GROUND FLOOR
F
P
P
P
P
P
J J
J
J
J
W F
W F
W F
F
F
F
C R
F
F F
F F
F
H
J
L
M
M.4
N
M.1
HH
JJ
GG
KK
2 3 4 5 6 7 8
0015E
0015A
S6
VEST
0020E
0015E
0015A
S6
VEST
0020E
0015E
0015A
S6
VEST
0020E
(TYP)
(TYP)
HVAC
0015E
CONTROLLED
SUBSTANCE
0015A
STAIR
S6
VEST
OF-002
SHELL
OF-001
PHARMAC
HVAC
0020E
HOUSEKEEPING
(R)
(ER)
(R)
(TYP)
(ER) (ER)
(ER)
(ER) (ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(R)
(R)
(TYP)
(TYP)
(TYP)
(TYP)
(ER)
(ER)(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(E R
(ER)
(ER)
(ER)
(ER)
(R)
(R)
(R)
(R)
(R)
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
VESTVESTVESTVEST
OF-003
(ER)
(ER)
(ER)
(ER)
(ER) (ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(R) (R) (R)
(R)
(R)
(R)
(R) (R)
(R) (R)(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(ER)
(ER)
(ER)
(ER) (ER)
(ER)
(ER)
(ER)
(ER)
(R)
(R)
(ER)
(ER)(ER)(ER)
(ER)(ER)
(ER)
(ER)
(ER)
(ER)
(E R)
(ER)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(ER)
(ER)
EXIT PASSAGEWAY
CO-1
(ER)
(R)
(R)
(ER)
(ER)
(ER) (ER)
(R)
(R)
(R)
(R)(R)
EP405
LEGEND:
(ER) - EXISTING TO REMAIN
(R) - RELOCATED
AREA NOT IN SCOPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:0
P
M
ED401
DEMOLITION LARGE SCALE VIEW-
PHARMACY
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
SCALE:
NORTH
ED101 1/4" = 1'-0"
1 DEMOLITION PLAN GROUND FLOOR - PHARMACY
GENERAL NOTES :
DEMOLITION KEY NOTES :
1. REMOVE SECURITY CAMERAS AND RETAIN FOR RE-USE.
2. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES,
SMOKE DETECTORS, STROBE, SPEAKERS, PULL BOX AND
RETAIN FOR RE- USE. DISCONNECT POWER WIRING BRANCH
CIRCUITRY AND BRING IT BACK TO SOURCE.
3. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.
4. ELECTRICAL PANELS TO REMAIN.
5. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,
SWITCHES. REFER TO ARCHITECTURAL DRAWINGS FOR
DETAILS OF ROOMS, CEILINGS TO BE REMOVED. DISCONNECT
POWER WIRING BRANCH CIRCUITRY AND BRING IT BACK TO
SOURCE.
187216
NOT TO SCALE
KEY PLAN - PHARMACY
GENERAL NOTES :
1. REFER TO SHEET EO000, EO001 AND FA000 FOR SYMBOLS,
DEMOLITION AND GENERAL NOTES RESPECTIVELY.
DEMOLITION KEY NOTES : #
FACP
F
F
P
P
P P
F
F
F
P P P
P
P
P
PP
P
P
P P
P
P
P
P
F F
F
P
P
P P
P
B
FF
GG
2 3 4 5 6 7 8
OFFICE
OFFICE
EXAM
OFFICE
0074 SUB WAITING
OFFICE
I.T
OFFICE
HSK
ELEC.
SECURITY OFFICE
ELEV.
E3
TOILET
STAFF LONGE/
LOCKER ROOM
WAITING
C03
PIPE
0014E
OFFICE
STOR.
MALE
FEMALE
OFFICE
MALE
FEMALE
HVAC
0017A
ELEV.
E1
ELEV.
MACH.
0018E
ELEV.
E2
PATIENT
FUNDS
AGENT
CASHIER
STOR.
0016A
STAIR
S1
(R)
(R)
(ER)
(ER)
(ER)
(ER)
(R)
(R)
(R)
EXISTING FIRE ALARM
CONTROL PANEL
TO REMAIN
A-8
(R)
(R)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)(ER)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)(R)
(R)
(R)
(R) (R) (R)
(R)
(R)(R)(R)
(R)
(R)
(TYP)
(TYP)
(TYP)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER) (ER)
(ER)
(ER)
(R)
CORRIDOR
C02
(ER)
(ER)
(ER) (ER)
(ER)
(ER)
EXISTING IT ROOM
EXISTING
ELECTRICAL ROOM
(R)
(R)(R)
(R)
(R)
(ER)
(ER)
(ER) (ER)
(R)
(R)
(R)
(TYP)
(TYP)
(TYP)
(ER)
(ER)
(ER)
(R)
(ER)
(ER)
(R)
(ER)
(ER)
(ER)(ER)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(ER)
A
7 8 9 10
STAIR
S5
ADMISSIONS
WAITING ROOM
(ER)
(R)
(R)
(R)
(TYP)
(TYP)
(ER)(ER)(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(R)
VESTIBULE
(ER) (ER) (ER)
(ER)
(ER)
(ER)
(R)
(R)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(TYP)
(TYP)
(TYP)
(TYP)
(R)
(R)
(R)
(R)
(R)
RECEPTION
(R)
(R)
(R)
LEGEND:
(ER) - EXISTING TO REMAIN
(R) - RELOCATED
AREA NOT IN SCOPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:0
P
M
ED402
DEMOLITION LARGE SCALE VIEW -
WAITING & ENTRANCE
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
SCALE:
NORTH
ED101 1/4" = 1'-0"
1 DEMOLITION PLAN GROUND FLOOR - PHARMACY WAITING
SCALE:
NORTH
ED101 1/4" = 1'-0"
2 DEMOLITION PLAN GROUND FLOOR - SOUTH ENTRANCE
GENERAL NOTES :
DEMOLITION KEY NOTES :
1. REMOVE SECURITY CAMERS AND RETAIN FOR RE-USE.
2. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES,
SMOKE DETECTORS, STROBE, SPEAKERS, PULL BOX AND
RETAIN FOR RE- USE.DISCONNECT POWER WIRING BRANCH
CIRCUITRY AND BRING IT BACK TO SOURCE.
3. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.
4. ELECTRICAL PANELS TO REMAIN.
5. REMOVE PANEL (E)A-8 IN WAITING-C03 AND RETURN TO OWNER
FOR RE-USE. REMOVE ALL ASSOCIATED CONDUITS AND
CONTROL WIRING BACK TO SOURCE.
6. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,
SWITCHES. REFER TO ARCHICHETURAL DRAWINGS FOR
DETAILS OF ROOMS, CEILINGS TO BE REMOVED. DISCONNECT
POWER WIRING BRANCH CIRCUITRY AND BRING IT BACK TO
SOURCE.
7. REMOVE ALL EXISTING PUBLIC ADDRESS SPEAKERS
DESIGNATED AS (R) CLEAN AND SAFE KEEP FOR
REINSTALLATION.
8. EXISTING PHARMACY PAGING SYSTEM AMPLIFIER LOCATED IN
CLOSET C03A, MICROPHONE AND PAGING SPEAKERS LOCATED
IN WAITING AREA SHALL BE DISCONNECTED AND REMOVED.
SYSTEM SHALL BE CLEANED, SAFE KEPT AND REUSED IN
TEMPORARY PHARMACY AND REUSED AGAIN IN PERMANENT
PHARMACY.
187216
NOT TO SCALE
KEY PLAN - WAITING AND ENTRANCE
1. REFER TO SHEET EO000, EO001 AND FA000 FOR SYMBOLS,
DEMOLITION AND GENERAL NOTES RESPECTIVELY.
FF
P
F
F
P
AOM
P
P
J
J
J
F
P
P
P
P
P
H
J
L
M
M.4
N
M.1
13.3
HH
JJ
GG
KK
8 9 10 11 12 13 14 15
HVAC
0021E
OFFICE
OFFICE
VENDING
EXAM SOUND
BOOTH
EXAM SOUND
BOOTH
OFFICE
CORRIDOR
C07
SHELL
OG-001
TYPICAL
(ER)
(ER)
(ER)
(ER)(ER)
(ER)
(ER)
(ER)
(R)
(R)
(R)
(R)
(ER)
(ER)
(ER)
(R)
(R)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER) (ER)
(ER)
(ER)(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
CORRIDOR
C05
EXIT PASSAGEWAY
CO-2
SECRETARY
EXAM SOUND BOOTH
CHIEF
HVAC
0042E
(ER)
(ER)
(R)
(R)(R)
(R) (R) (R)
(R)(R)(R)
(R) (R)
(R) (R) (R)
(R) (R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(TYP)
(TYP)
(ER)
(ER)
(R)
(R)
(R)
(R)
(ER)
(R)
(ER)
(TYP)
(ER)
(R)
LEGEND:
(ER) - EXISTING TO REMAIN
(R) - RELOCATED
AREA NOT IN SCOPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:1
P
M
ED403
DEMOLITION LARGE SCALE VIEW -
OPEN OFFICE AND AUDIOLOGY
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
SCALE:
NORTH
ED101 1/4" = 1'-0"
1 DEMOLITION PLAN GROUND FLOOR - OPEN OFFICE AND AUDIOLOGY
GENERAL NOTES :
DEMOLITION KEY NOTES :
1. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES.
RETAIN FOR RE- USE.
2. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.
3. ELECTRICAL PANELS TO REMAIN.
4. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,
SWITCHES ETC. TO BE DEMOLISHED. REFER TO
ARCHICHETURAL DRAWINGS FOR DETAILS OF ROOMS,
CEILINGS TO BE REMOVED. DISCONNECT POWER WIRING
BRANCH CIRCUITRY AND BRING IT BACK TO SOURCE.
5. REMOVE ALL EXISTING PUBLIC ADDRESS SPEAKERS
DESIGNATED AS "R" CLEAN AND SAFE KEEP FOR
REINSTALLATION.
NOT TO SCALE
KEY PLAN - OPEN OFFICE AND AUDIOLOGY
187216
GENERAL NOTES :
DEMOLITION KEY NOTES : #
1. REFER TO SHEET EO000,EO001 AND FA000 FOR SYMBOLS,
DEMOLITION AND GENERAL NOTES RESPECTIVELY.
100% BID DOCUMENTS
(R)
FF
F
F
SR
CB
SR
CB
SR
CB
SR
CB
S R
C B
S R
C B
F
S R
C B
S R
C B
S R
C B
S R
C B
SR
CB
SR
CB
SR
CB
S R
C B
F
F
F
P
P
P
P
P
P
F
F
P P
P
P
P
P
PP
P
P
P
P
P P
13.3
A
B
13.2
FF
GG
8 9 10
11 12 13
14 15
CORRIDOR
C07
WAITING
PROSTHETICS
TREATMENT
(ER)
(ER)
(R)
(R)
(R)
ER
R
(R)
(R)
ER
(ER)
RECEPTION
PATIENT
INFORMATION
EQUIP.
STAFF LOUNGE
TOILET
ROOM
TREATMENT
CORRIDOR
C01
CORRIDOR
C011
CORRIDOR
C012
CORRIDOR
C06
STORAGE
0110 TRIAGE
TRIAGE
TRIAGE
OFFICE
EXAM
EXAM
EXAM
TOILET
0122A
EXAM
NURSE
STATION
IMMEDIATE CARE
OFFICE
0103A
TELE
0050E
OFFICE
RECORDS
HVAC
0050A
MEN'S
WOMEN'S
CORRIDOR
C09
CORRIDOR
C08
RECOVERY
TOILET
0092A
DRESSING ROOM
SOILED UTILITY
(R)
(ER)
(ER) (ER)
(ER)
(ER)
(ER)
(ER)
(TYP)
(TYP)
(TYP)
CORRIDOR
C013
HSK
CORRIDOR
C010
CORRIDOR
C08
STOR.
STAIR
S2
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)(R)
(R) (R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(ER)
(ER)
(ER) (ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(R)
(R)
(R)(R) (R)
(R) (R) (R)
(R)
(R)
(R)
(R)
(R)
(R) (R) (R)
(R)
(R)
(R)
(R)
EY407
(TYP)
(R)
(R)
(R)
(R)
(R) (R)
(R)
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R) (R)(R)
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R) (R) (R)
(R) (R)
(R) (R)
(R)
(R) (R)
(R)
(TYP.)
(R)
(R)
(R)
(R)
(ER) (ER)(ER)
(R)
LEGEND:
(ER) - EXISTING TO REMAIN
(R) - RELOCATED
AREA NOT IN SCOPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:5
:4
P
M
ED404
DEMOLITION LARGE SCALE VIEW -
URGENT CARE
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
SCALE:
NORTH
ED101
1/4" = 1'-0"
1 DEMOLITION PLAN GROUND FLOOR - URGENT CARE
GENERAL NOTES :
DEMOLITION KEY NOTES :
1. REMOVE SECURITY CAMERS AND RETAIN FOR RE-USE.
2. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES.
RETAIN FOR RE- USE.
3. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.
4. ELECTRICAL PANEL A-1 AND A-2 ARE RELOCATED TO NEW
LOCATION. REMOVE ALL ASSOCIATED CONDUITS AND
CONTROL WIRING BACK TO SOURCE.
5. ELECTRICAL PANELS TO REMAIN.
6. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,
SWITCHES ETC. TO BE DEMOLISHED. REFER TO
ARCHICHETURAL DRAWINGS FOR DETAILS OF ROOMS,
CEILINGS TO BE REMOVED. DISCONNECT POWER WIRING
BRANCH CIRCUITRY AND BRING IT BACK TO SOURCE.
7. CONTRACTOR SHALL REMOVE DOOR MAGNATIC DOOR
HOLDER, SMOKE DETECTORS, STROBE, SPEAKER, PULL BOX
AND POWER WIRING BRANCH CIRCUITRY BACK TO SOURCE.
8. REMOVE ALL EXISTING PUBLIC ADDRESS SPEAKERS
DESIGNATED AS "R" CLEAN AND SAFE KEEP FOR
REINSTALLATION.
NOT TO SCALE
KEY PLAN - URGENT CARE
187216
GENERAL NOTES :
DEMOLITION KEY NOTES : #
1. REFER TO SHEET EO000, EO001 AND FA000 FOR SYMBOLS,
DEMOLITION AND GENERAL NOTES RESPECTIVELY.
REF.REF.
REF.
REF.
UP
H
J
L
M
M.4
N
M.1
13.3
A
B
13.2
HH
FF
JJ
GG
KK
12 3 4 5 6 7 8 9 10 11 12 13 14 15
EL402
EL403
EL404
EL402
EL401
TEMPORARY
PHARMACY
(PHASE 1) OPEN
OFFICE AND
AUDIOLOGY
(PHASE 3)
PHARMACY
(PHASE 2)
URGENT CARE
(PHASE 4)
SHADE INDICATES
APPROXIMATE
AREA OUT OF
SCOPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202
317.800.6388 | WWW.GUIDONDESIGN.COM
GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126
313.441.3000 | WWW.GHAFARI.COM
C g h a fa ri l o c a l c a c h e \R e v it \1
E
C
E N
T R
A L rv t_ p h e ro h a lli .r v t
/1
/2
:2
:2
P
M
EL101
LIGHTING PLAN GROUND FLOOR
COMPOSITE
RENOVATE PHARMACY &
URGENT CARE
5500 Armstrong Road, Battle Creek
515-18-109
05/20/2020 M. Sabapathy P. Herohalli
100% BID DOCUMENTS
PART. SPRINKLERED
SCALE:
NORTH
EP405 3/32" = 1'-0"
1 LIGHTING PLAN GROUND FLOOR COMPOSITE
GENERAL NOTES :
1. REFER TO SHEET EO000 AND EO001 FOR SYMBOLS, DEMOLITION
AND GENERAL NOTES.
2. REFER TO LUMINAIRE SCHEDULE ON SHEET EL701 FOR THE
LUMINAIRE DESCRIPTION AND MOUNTING HEIGHTS, UNLESS
OTHERWISE NOTED.
187216
NOT TO SCALE
KEY PLAN - GROUND FLOOR
REF. REF.
D D
OS
D D
3D
D
D
D
D
OS
OS
OS
OS
OS
3D
OS
OS
OS
OS
OS
OS
D
OS
OS
OS
OS
H
J
L
M
M.4
N
M.1
HH
JJ
GG
KK
2 3 4 5 6 7 8
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2L1
LP-CB6;2
L1
LP-CB6;2
EL1
EP-CB1;2
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
EL1
EP-CB2;14
L1
LP-CB6;2
EL1
EP-CB2;14
EL1
EP-CB2;14
EL1
EP-CB2;14
L1
LP-CB6;2
EL1
EP-CB2;14
L1
LP-CB6;2
L1
LP-CB6;2 EL1
EP-CB2;14
L1
LP-CB6;2
L1
LP-CB6;2
EL1
EP-CB2;14
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
EL1
EP-CB2;14
L1
LP-CB6;2
EL1
EP-CB2;14
EL1
EP-CB2;14
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
EL1
EP-CB2;14
L1
LP-CB6;2
L1
LP-CB6;2
L1
LP-CB6;2
LP-CB6
EL1
EP-CB2;14
EL6
(R)EL6
(ER)
MDP-4
RP-CB6
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)(ER)
(ER)
(ER)
X1
E…
This is the start of the file's text. The full file is on GovTribe.