515-18-109 Bid Drawings - Signed_Part5.pdf

PDF 14 MB Posted

Attached to
Z1DA--Renovate Outpatient Pharmacy & Urgent Care 515-18-109
Solicitation number
36C25020B0058
Issued by

About this file

This document outlines a federal contract opportunity to renovate the outpatient pharmacy and urgent care center at the Battle Creek Healthcare System in Battle Creek, Michigan. The solicitation number is 36C25020B0058 and seeks bids to furnish all labor, materials, supervision, equipment, tools and other necessary resources for the project according to contract specifications, drawings, terms and conditions. An organized site visit is scheduled and sealed bids must be delivered to the specified address by 2:00PM on September 10, 2020. The project number is 515-18-109. This procurement is a 100% set-aside for Service Disabled Veteran Owned Small Businesses and has a $39.5 million small business size standard. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

H

J

L

M

M.4

N

M.1

13.3

A

B

C

DD

3.8 4.9 5.3 5.7 6.5 10.6 10.8 11.3 11.8 11.9 13.2

EE

HH

FF

JJ

GG

KK

1 2 3 4 5 6

8 9

11 12 13 14 15

MP402

MP401

MP402

MP403

MP404

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE

WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH

HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.

5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS

NOTED OTHERWISE.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC

ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE

WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS

AND INSTRUCTIONS. GOVERNMENT'S PREFER ROUTING IS

SHOWN - IF THE ROUTING MUST DIFFER FROM THE

PROPOSED, COORDINATE WITH A/E & GOVERNMENT.

COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,

AND WITH NEW CONSTRUCTION ELEMENTS.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:5

P

M

MP101

PIPING PLAN GROUND FLOOR

COMPOSITE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

NORTH

3/32" = 1'-0"

PIPING PLAN GROUND FLOOR COMPOSITE

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - GROUND FLOOR

Revisions: Date:

J

L

M

M.4

N

M.1

HH

JJ

GG

KK

1 2 3 4 5 6 7 8

VAV-11

VAV-07

VAV-08

VAV-12

VAV-05

VAV-04

VAV-06

VAV-09

VAV-10

VAV-03

VAV-02

VAV-01

3/4"ø HWR 3/4"ø HWS

3/4"ø HWR

3/4"ø HWS

3/4"ø HWR

3/4"ø HWS

3/4"ø HWS

3/4"ø HWR

3/4"ø HWR

3/4"ø HWS

3/4"ø HWR

3/4"ø HWS

3/4"ø HWR 3/4"ø HWS

3/4"ø HWR

3/4"ø HWS

3/4"ø HWR 3/4"ø HWS

1"ø HWS

1"ø HWR

3/4"ø HWS 3/4"ø HWR

3/4"ø HWS

3/4"ø HWR

3/4"ø HWR

3/4"ø HWS

1"ø HWS

1"ø HWR 1"ø HWS

1"ø HWR

1 1/2"ø HWS

1 1/2"ø HWR

(E) 3/4"ø PC

(E) 2"ø LPS

(E) 3"ø CHWR

(E) 3"ø HWS

(E) 3"ø CHWS

(E) 3"ø HWR

(E) 1"ø HWR

(E) 1"ø HWS

3/4"ø HWR 3/4"ø HWS

1"ø HWS 1"ø HWR

CONNECT TO

40 PSI STEAM

MAIN

SHUT-OFF

VALVE (TYP)

RELOCATE EXISTING

STRAINER, VALVES

AND CONTROLLER

MH401

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE

WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH

HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.

5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS

NOTED OTHERWISE.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC

ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE

WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS

AND INSTRUCTIONS. GOVERNMENT'S PREFERRED

ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM

THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.

COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,

AND WITH NEW CONSTRUCTION ELEMENTS.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:0

P

M

MP401

PIPING LARGE SCALE VIEW -

PHARMACY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

MP101

1/4" = 1'-0"

1 PIPING PLAN GROUND FLOOR - PHARMACY

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - PHARMACY

B

C

DD

3.8 4.9 5.3 5.7

6.5

EE

FF

GG

1 2 3 4 5 6

7 8

VAV-13

VAV-14

VAV-15

VAV-17

VAV-16

3/4"ø HWR

3/4"ø HWS 3/4"ø HWS 3/4"ø HWR

(E) PIPING AND CONDUIT TO

BE REWORKED IN THIS AREA

TO COORDINATE WITH NEW

DUCT AND UTILITIES; COORD

WITH ALL TRADES PRIOR TO

START OF WORK

NOTE 8

ROUTE LINES DOWN

EXTERIOR OF WALL,

COORDINATE WITH

EXISTING WINDOW

LOCATIONS, SEE

NOTE 8

ACU-02-EVAP

ROUTE PUMPED

CONDENSATE FROM

EVAPORATOR TO NEARBY

HOUSEKEEPING CLOSET

ROUTE REFG LINES IN

CEILING SPACE, COORD W/

ALL TRADES, SEE NOTE 8

ACU-02-COND

A

7 8 9 10

1 1/4"ø HWR

1 1/4"ø HWS

CUH-01

(E) 3/4"ø HWS

(E) 3/4"ø HWR

(E) 3/4"ø HWS

(E) 3/4"ø HWR

UP

UP

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE

WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH

HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.

5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS

NOTED OTHERWISE.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC

ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE

WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS

AND INSTRUCTIONS. GOVERNMENT'S PREFERRED

ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM

THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.

COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,

AND WITH NEW CONSTRUCTION ELEMENTS.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:1

P

M

MP402

PIPING LARGE SCALE VIEW -

WAITING AND ENTRANCE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

MP101

1/4" = 1'-0"

1 PIPING PLAN GROUND FLOOR - PHARMACY WAITING

SCALE:

MP101

1/4" = 1'-0"

2 PIPING PLAN GROUND FLOOR - SOUTH ENTRANCE

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - WAITING AND ENTRANCE

KEYNOTES

MOUNT ON WALL, INSTALL PER MANUFACTURER'S

INSTRUCTIONS. REFER TO DETAIL ON AS502.

COORDINATE WITH ARCH FOR PENETRATIONS THROUGH

EXTERIOR WALL, SEAL PENETRATIONS WATERTIGHT.

L

M

M.4

N

M.1

13.3

HH

JJ

GG

KK

8 9 10 11 12 13 14 15

MH403

VAV-22

VAV-21

VAV-23

VAV-25

VAV-20

VAV-19

VAV-18

3/4"ø HWS

3/4"ø HWR

1"ø HWR

1"ø HWS

1"ø HWS

1"ø HWR

3/4"ø HWR

3/4"ø HWS

1"ø HWS

1"ø HWR

2"ø HWR

2"ø HWS

1"ø HWR 1"ø HWS 1"ø HWR

1"ø HWS

(E) 3/4"ø HWR

(E) 3/4"ø HWS

(E) 3/4"ø SC

(E) 2"ø LPS

(E) 3"ø CHWS

(E) 3"ø CHWR

(E) 3"ø HWS

(E) 3"ø HWR

2"ø MPS

2"ø MPS

RELOCATE EXISTING

STRAINER, VALVES AND

CONTROLLER

3/4"ø HWS 3/4"ø HWR

SHUT-OFF

VALVE (TYP)

RELOCATED

PIPING &

VALVES

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE

WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH

HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.

5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS

NOTED OTHERWISE.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC

ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE

WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS

AND INSTRUCTIONS. GOVERNMENT'S PREFERRED

ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM

THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.

COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,

AND WITH NEW CONSTRUCTION ELEMENTS.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:2

P

M

MP403

PIPING LARGE SCALE VIEW - OPEN

OFFICE AND AUDIOLOGY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

MP101

1/4" = 1'-0"

1 PIPING PLAN GROUND FLOOR - OPEN OFFICE AND AUDIOLOGY SCALE:

NORTH

1" = 50'-0"

KEY PLAN - OPEN OFFICE AND AUDIOLOGY

13.3

A

B

C

DD

10.6 10.8 11.3 11.8 11.9 13.2

EE

FF

GG

8 9 10

11 12 13

14 15

VAV-24

VAV-37

VAV-38

VAV-36

CUH-02

VAV-35

VAV-34

DCP-01

VAV-33

VAV-32

VAV-31

VAV-28

VAV-26

VAV-27

VAV-29

1 1/4"ø HWR

1 1/4"ø HWS

(E) 3/4"ø HWR

(E) 3/4"ø HWS

1"ø HWR

1"ø HWS 1"ø HWR

1"ø HWR

1"ø HWS 3/4"ø HWS

3/4"ø HWR

3/4"ø HWS 3/4"ø HWR

3/4"ø HWR

3/4"ø HWS

PRESSURE POWERED

CONDENSATE PUMPS:

DUPLEX WITH RECEIVER, 4,000

LB/HR CAPACITY, BACKPRESSURE

15 PSI, MOTIVE PRESSURE 40 PSI

3/4"ø SC

3/4"ø SC

ROUTE STM COND PREVIOUSLY

RETURN TO COND PUMP IN

THIS LOCATION TO PUMP

DCP-01

ROUTE STM COND PREVIOUSLY

RETURN TO COND PUMP IN

THIS LOCATION TO PUMP

DCP-01

2"ø MPS

SHUT-OFF

VALVE (TYP)

ACU-01-EVAP

3/4"ø HWS

3/4"ø HWR

3/4"ø HWS

3/4"ø HWR

1"ø HWS

1"ø HWR

1"ø HWS

VAV-30

ROUTE PUMPED

CONDENSATE FROM

EVAPORATOR TO FLOOR

DRAIN IN NEARBY

MECHANICAL CLOSET

ROUTE REFG LINES IN

CEILING SPACE,

COORD W/ ALL

TRADES, SEE NOTE 8

ACU-01-COND

ROUTE LINES DOWN

EXTERIOR OF WALL,

COORDINATE WITH

EXISTING WINDOW

LOCATIONS, SEE NOTE 8

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. LOCATE AIR VENTS AT ALL LOCAL HIGH POINTS WHERE

WATER IS FLOWING UPWARD, AND DRAIN VALVES WITH

HOSE CONNECTIONS AT ALL LOCAL LOW POINTS.

5. BRANCH RUN-OUTS TO VAV BOXES ARE 3/4", UNLESS

NOTED OTHERWISE.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

8. REFRIGERANT LINES - ROUTING SHOWN IS SCHEMATIC

ONLY, ACTUAL ROUTING BY CONTRACTOR IN ACCORDANCE

WITH SPLIT SYSTEM MANUFACTURER'S REQUIREMENTS

AND INSTRUCTIONS. GOVERNMENT'S PREFERRED

ROUTING IS SHOWN - IF THE ROUTING MUST DIFFER FROM

THE PROPOSED, COORDINATE WITH A/E & GOVERNMENT.

COORDINATE WITH EXISTING STRUCTURE AND SYSTEMS,

AND WITH NEW CONSTRUCTION ELEMENTS.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:4

P

M

MP404

PIPING LARGE SCALE VIEW -

URGENT CARE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

MP101

1/4" = 1'-0"

1 PIPING PLAN GROUND FLOOR - UREGENT CARE

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - URGENT CARE

AIR FLOW

THERMOMETER (TYP)

PRESSURE AND

TEMPERATURE TEST

PLUG (TYP)

MANUAL AIR VENT

HEATING COIL

CONTROL VALVE

FLOW MEASURING DEVICE

BALANCING VALVE

WITH MEMORY STOP

(SEE SPECS FOR VALVE

DETAILS)

HWR

SHUT-OFF VALVE

HWS

UNION (TYP)

DRAIN VALVE WITH

HOSE END

CONNECTION

SHUT-OFF VALVE

STEAM, GAS, OR AIR PIPING

BRANCH SECTIONALIZING

VALVE, OR EQUIPMENT

SHUT-OFF VALVE

SUPPLY MAIN

BRANCH PIPING

OFF TOP OF MAIN

WATER PIPING

BRANCH SECTIONALIZING

VALVE, OR EQUIPMENT

SHUT-OFF VALVE

SUPPLY OR

RETURN MAIN

BRANCH PIPING OFF

BOTTOM OF MAIN

NOTE: BRANCHES MAY BE 45 OR 90 DEGREES ABOVE/BELOW MAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:4

P

M

MP501

PIPING DETAILS RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

NOT TO SCALE

HOT WATER HEATING COIL PIPING DIAGRAM

NOT TO SCALE

PIPING BRANCH CONNECTIONS

J J

PANEL;CIRCUIT

D

DT

K

KP

LV

LM

MC

P

T

WP

PS

XP

HP

D

OS OS

CONDUIT UP

GROUND ROD

CONDUIT HOME RUN TO PANEL

CONDUIT RUN

UNDERGROUND GROUND WIRE

UNDERGROUND TELECOMMUNICATIONS CONDUIT / DUCT BANK

UNDERGROUND ELECTRICAL CONDUIT / DUCT BANK

JUNCTION BOX

WEATHERPROOF SWITCH

TIMER SWITCH

VACANCY SENSOR SWITCH

LOW VOLTAGE MASTER SWITCH

LOW VOLTAGE SWITCH

KEY OPERATED W/ PILOT LIGHT SWITCH

THREE-WAY SWITCH

DOUBLE POLE SWITCH

SINGLE POLE TOGGLE SWITCH

KEY OPERATED SWITCH

MOMENTARY CONTACT SWITCH

SINGLE POLE/DOUBLE THROW SWITCH

FOUR-WAY SWITCH

DIMMING MASTER CONTROL

MOTORIZED PROJECTION SCREEN SWITCH

EXPLOSION-PROOF SWITCH

DIMMER SWITCH

HORSEPOWER RATED SWITCH

VACANCY/OCCUPANCY SENSOR -

WALL / CEILING MOUNTED

POLE MOUNTED FIXTURE - DOUBLE HEAD

POLE MOUNTED FIXTURE - SINGLE HEAD

PULL BOX

GROUND TEST WELL

LIGHTNING PROTECTION COPPER DOWN CONDUCTOR

CADWELD CABLE CONNECTION

AIR TERMINAL

GROUND BUS

PB

LIGHTNING PROTECTION /

GROUNDING SYMBOL LIST

WIRING SYMBOL LIST

POWER SYMBOL LIST

LIGHTING SYMBOL LIST

SWITCHING SYMBOL LIST

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

G

T

E

GFR

CAPACITOR

VALUE AS

INDICATED ON

DRAWINGS

V

G

A

SINGLE LINE DIAGRAM SYMBOL LIST

CONTACTOR - NORMALLY OPEN

CONTACTOR - NORMALLY CLOSED

LINE TERMINATOR

ELECTRICAL CONNECTOR

GROUND

FUSE

DISCONNECT SWITCH

TRANSFORMER

JAGGED RESISTOR

VOLTAGE REGULATOR

3-PHASE MOTOR

WYE CONNECTION

SERVICE WEATHERHEAD

METER

CONTROL TRANSFORMER

POTENTIAL TRANSFORMER

CURRENT TRANSFORMER

CABLE POT HEAD

CIRCUIT BREAKER

DELTA CONNECTION

BATTERY

SURGE ARRESTOR

DRAW OUT, LOW VOLTAGE CIRCUIT BREAKER

GROUND FAULT RELAY

AUTOMATIC TRANSFER SWITCH

H.R.C FUSE RATING AS INDICATED ON

DRAWING

RATINGS AS INDICATED ON DRAWING

H.R.C FUSED CUT-OUT

SURGE PROTECTION DEVICE

LIGHTNING ARRESTOR

POWER FACTOR CORRECTION CAPACITOR BANK

POTENTIAL TRANSFORMER WITH PRIMARY

AND SECONDARY FUSES

FULL VOLTAGE NON-REVERSIBLE MOTOR

STARTER AND OVERLOAD RELAY,

MOUNTED IN MOTOR CONTROL CENTER

REDUCED VOLTAGE (STAR/DELTA) NON-

REVERSIBLE MOTOR STARTER AND OVERLOAD

RELAY, MOUNTED IN MOTOR CONTROL CENTER

OVERLOAD RELAY

KEY INTERLOCK

AMMETER, VOLTMETER

AMMETER, VOLTMETER SELECTOR SWITCH

INDICATOR LAMP

STAND-BY DIESEL GENERATOR SET

COMBINATION POWER MONITORING SYSTEM,

PROGRAMMING AND DISPLAY

ADDRESSABLE ELECTRONIC MODULE

DRAW OUT, MEDIUM VOLTAGE VACUUM

CIRCUIT BREAKER (VCB)

M

SPD

ASS VSS

K

AEM

ELECTRICAL BUS DUCT WITH FUSIBLE BUS PLUGS

BAT

PC

C

EMERGENCY LIGHTING FIXTURE - CEILING MOUNTED

LIGHTING FIXTURE - CEILING SURFACE MOUNTED

LIGHTING FIXTURE - CEILING / PENDANT / WALL MOUNTED

LINEAR WALL WASHER LIGHTING FIXTURE - CEILING / PENDANT MOUNTED

SPOT LIGHT FIXTURE

TRACK LIGHTING, LENGTH AND NUMBER OF FIXTURES AS INDICATED ON DRAWINGS

INDUSTRIAL LIGHTING FIXTURE - CEILING / WALL MOUNTED

EXIT SIGN - CEILING / WALL MOUNTED, HATCH INDICATES NUMBER OF

FACES, ARROWS AS INDICATED ON PLANS

BATTERY OPERATED EMERGENCY LIGHTING UNIT - CEILING / WALL MOUNT

SINGLE REMOTE HEAD EMERGENCY LIGHTING UNIT - CEILING / WALL MOUNT

DUAL REMOTE HEAD EMERGENCY LIGHTING UNIT - CEILING / WALL MOUNT

EMERGENCY LIGHTING UNIT BATTERY

REEL LIGHT

PHOTO CELL

LIGHTING CONTACTOR

LIGHTING FIXTURE - PENDANT / WALL MOUNTED

POLE MOUNTED FIXTURE - THREE HEAD

POLE MOUNTED FIXTURE - FOUR HEAD

STATIC GROUNDING RECEPTACLEG

HOT

CONDUCTOR

GROUND

CONDUCTOR

NEUTRAL

CONDUCTOR

SHUNT TRIPST

PM

1-PHASE MOTOR

EXISTING

NEW

LINETYPE LEGEND

OS OCCUPANCY SENSOR SWITCHS

INSTANTANEOUS OVER CURRENT

OR RATE OF RISE RELAY

TIME PHASE OVER CURRENT RELAY

GROUND INSTANTANEOUS AND TIME

OVER CURRENT RELAY

50N/51N

ANSI RELAY DESIGNATIONS

POWER FACTOR RELAY55

UNDERVOLTAGE RELAY27

OVERVOLTAGE RELAY59

FREQUENCY RELAY81

86 LOCKOUT RELAY

DIFFERENTIAL PROTECTION RELAY87

DEMOLITION

CONDUIT DOWN

FIXED CAPACITOR

RL

EMERGENCY LIGHTING FIXTURE - PENDANT / WALL MOUNTED

EMERGENCY LIGHTING FIXTURE - CEILING / PENDANT / WALL MOUNTED

LIGHTING FIXTURE IDENTIFIERS (REFER TO LIGHTING FIXTURE SCHEDULE):

"C" COMPACT FLUORESCENT TYPE

"F" FLUORESCENT LIGHTING FIXTURE TYPE

"H" HID LIGHTING FIXTURE TYPE

"L" LED LIGHTING FIXTURE TYPE

"S" SITE LIGHTING FIXTURE TYPE

"T" TRACK LIGHTING FIXTURE TYPE

"X" EXIT SIGN FIXTURE TYPE

"EM" EMERGENCY LIGHTING FIXTURE TYPE

"NL" NIGHT LIGHT FIXTURE TYPE

"+ X' - X" (or XXXXMM) AFF" LIGHT FIXTURE MOUNTING HEIGHT ABOVE FINISHED FLOOR

TH THERMAL OVERLOAD SWITCHS

WALL WASHER LIGHTING FIXTURE - CEILING / PENDANT MOUNTED

EMERGENCY INDUSTRIAL LIGHTING FIXTURE - CEILING / WALL MOUNTED

ELECTRICAL EQUIPMENT DESIGNATION LEGEND

EQUIPMENT SEQUENCE NUMBER

01, 02, 03, etc.

LEVEL

0 LEVEL G (GROUND FLOOR)

1 LEVEL 1 (FIRST FLOOR)

2 LEVEL 2 (SECOND FLOOR)

R LEVEL R (ROOF)

EQUIPMENT ABBREVIATIONS

ATS AUTOMATIC TRANSFER SWITCH

BAT BATTERY

BTC BATTERY CHARGER

CAP CAPACITOR BANK

CBS CENTRAL BATTERY INVERTER SYSTEM

DCP 28V DC PANEL

DP DISTRIBUTION PANEL

ECAP CAPACITOR BANK FED FROM EMERGENCY SWB

EDP EMERGENCY DISTRIBUTION PANEL STANDBY GENERATOR POWER

ELP EMERGENCY LIGHTING PANEL STANDBY GENERATOR POWER

EMLP EMERGENCY LIGHTING PANEL BATTERY POWER

ERP EMERGENCY RECEPTACLE PANEL STANDBY GENERATOR POWER

ESDP EMERGENCY SUB-DISTRIBUTION PANEL STANDBY GENERATOR

POWER

ESWB EMERGENCY LOW VOLTAGE SWITCHBOARD

FP FEEDER PILLAR

GEN GENERATOR

GPU 400Hz GROUND POWER UNIT

LB LOAD BANK

LP LIGHTING PANEL NORMAL POWER

LRP LIGHTING RELAY PANEL

MCC LOW VOLTAGE MOTOR CONTROL CENTER

SWB LOW VOLTAGE SWITCHBOARD

MPSWG MEDIUM VOLTAGE PARALLELING SWITCHGEAR

MSWG MEDIUM VOLTAGE SWITCHGEAR

PIT POP-UP UTILITY PIT

RP RECEPTACLE PANEL

SDP SUB-DISTRIBUTION PANEL

TR DRY-TYPE TRANSFORMER

ULP LIGHTING PANEL UPS POWER

UPS UNINTERRUPTIBLE POWER SUPPLY

URP RECEPTACLE PANEL UPS POWER

VFD VARIABLE FREQUENCY DRIVE

XXXX - X XX

UNDERGROUND ELECTRICAL CONDUIT

CABLE TRAY (TYPE AND SIZE INDICATED ON DRAWINGS)

CABLE TRAY UP OR DOWN OR SECTION CUT

DL DAYLIGHT SENSOR

LIGHTING FIXTURE - CEILING RECESSED

SWITCH W/ PILOT LIGHT

VSS

VS VS

EMERGENCY LIGHTING FIXTURE - CEILING

RECESSED

SINGLE RECEPTACLE - WALL, HORIZONTAL, ABOVE COUNTER,

EMERGENCY, FULLY CONTROLLED, CEILING, FLOOR

RECEPTACLE, 220V, 3 PHASE - SINGLE, DUPLEX

RECEPTACLE, 240/208V, 3 PHASE - WALL, FLOOR

RECEPTACLE, 480V, 3 PHASE - WALL, FLOOR

POWER POLE

ELECTRICAL EQUIPMENT - TYPE OF EQUIPMENT AS INDICATED

RECESSED ELECTRICAL PANEL

SURFACE MOUNTED ELECTRICAL PANEL

CONTROL PANEL

DOOR CONTROL PANEL

COMBINATION DISCONNECT SWITCH / MOTOR STARTER

FUSED DISCONNECT SWITCH

NON-FUSED DISCONNECT SWITCH

1-PHASE MOTOR, "X" DENOTES HORSE POWER

MOTOR STARTER

VARIABLE FREQUENCY DRIVE

PUSHBUTTON - 2 BUTTON, W/ PILOT LIGHT

PUSHBUTTON - 3 BUTTON, W/ PILOT LIGHT

PUSHBUTTON - EMERGENCY OFF

ELECTRICAL BUS DUCT W/ FUSIBLE BUS PLUGS

UTILITY METER

CABLE TRAY

PUSHBUTTON - 1 BUTTON, W/ PILOT LIGHT

RECEPTACLE, 240/208V, 3 PHASE, W/DISCONNECT - FUSED,

W/DISCONNECT - NON-FUSED - WALL

RECEPTACLE, 480V, 3 PHASE, W/DISCONNECT - FUSED,

W/DISCONNECT - NON-FUSED - WALL

MANUAL MOTOR STARTER

C

C

DUPLEX RECEPTACLE - WALL, HORIZONTAL, ABOVE COUNTER, HOSPITAL

GRADE, EMERGENCY, FULLY CONTROLLED, HALF CONTROLLED, HOSPITAL

GRADE EMERGENCY, CEILING, FLOOR

QUADPLEX RECEPTACLE - WALL, HORIZONTAL, ABOVE COUNTER, HOSPITAL

GRADE, EMERGENCY, FULLY CONTROLLED, HALF CONTROLLED, HOSPITAL

GRADE EMERGENCY, CEILING, FLOOR

C

X

3-PHASE MOTOR, "X" DENOTES HORSE POWERX

RECEPTACLE IDENTIFIERS:

"GFCI" GROUND FAULT CIRCUIT INTERRUPTER

"IG" ISOLATED GROUND

"PT" POKE THRU

"WP" WEATHERPROOF

"TP" TAMPER PROOF

"XP" EXPLOSION PROOF

"USB" UNIVERSAL SERIAL BUS OUTLET.

M

CPCP

DCPDCP

VFDVFD

PP

D THREE WAY-DIMMER SWITCHS3

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

(ALL MAY NOT APPLY)

CENTERLINE

SWITCH

WIREMOLD

COUNTER

VOICE/DATA POWER

CENTERLINE

POWER VOICE/DATA

CENTERLINE

THERMOSTAT

CARD READER

SWITCH

2'

(MIN.) 4'3'-10" 3'-8"

6' 6'-8"

3'-10" 3'-10"

OR PER

PROJECTCODE

REQUIREMENTS

HIGHEST

DISCONNECT

/ BREAKER

BACKSPLASH

(WHERE

PRESENT)

MAXIMUM

HEIGHT

OPERATING

CONTROLS

NURSE CALL

CONTROLS

FIRE ALARM

AUDIBLE

VISUAL

STROBE

FIRE ALARM

PULL BOX

TYPICAL

AREA

HAZARDOUS

AREAS

OUTLETS

UNFINISHED

AREAS

SWITCHES &

CONTROLS

WALL MOUNTED

TELEPHONE

ELECTRIC

PANEL

DEVICES OVER

COUNTERS

FINISHED

FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:0

P

M

EO000

ELECTRICAL SYMBOL LIST RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

NOT TO SCALE

MOUNTING HEIGHTS

187216

NOTE:

MOUNTING HEIGHT OF NEW FIRE ALARM DEVICES SHALL

MATCH EXISTING.

100% BID DOCUMENTS

1. DRAWINGS ARE DIAGRAMMATIC AND INDICATE DESIGN INTENT.

2. DO NOT SCALE DRAWINGS.

3. FIELD-VERIFY EXISTING CONDITIONS AND ACTUAL DIMENSIONS PRIOR TO START OF WORK.

4. COORDINATE ELECTRICAL WORK WITH OTHER TRADES TO AVOID PHYSICAL CONFLICTS AND CONFLICTS WITH

WORK SEQUENCE.

5. REFER TO ARCHITECTURAL DRAWINGS FOR WALLS WITH SPECIAL WALL FINISHES. COORDINATE OVERALL WALL

COVERING THICKNESS AND PROVIDE PLASTER RING WITH APPROPRIATE DEPTH.

6. REFER TO ONE-LINE OR RISER DIAGRAM FOR CONDUIT AND FEEDER SIZES.

7. BRANCH WIRING SHALL BE SIZED PER THE SCHEDULES, UNLESS OTHERWISE NOTED, DERATING OF WIRE HAS BEEN INCORPORATED INTO SIZES SHOWN ON SCHEDULES. ADDITIONAL DERATING, IF NECESSARY, SHALL COMPLY WITH NEC SECTION 310.15. DUE TO HARMONIC LOADING, THE NEUTRAL CONDUCTOR SHALL BE CONSIDERED AS

CURRENT CARRYING CONDUCTOR FOR DERATING PURPOSES.

8. CONDUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC ARTICLE 250.

9. CONDUIT AND WIRING SHALL BE CONCEALED IN WALL OR CEILING CAVITY EXCEPT FOR EXISTING BLOCK WALLS AND AREAS WITH EXPOSED CEILING CONSTRUCTION. AREAS WITH NEW WALLS OR RECONSTRUCTED WALLS SHALL HAVE CONDUIT AND WIRING CONCEALED IN WALL CAVITY. EXPOSED CONDUIT IN LOW AND HIGH BAY STORAGE, MANUFACTURING, ASSMEBLY, MAINTENANCE, AND SHIPPING AND RECEIVING AREAS SHALL BE RGS (RIGID GALVANIZED STEEL) UP TO 10 FT HEIGHT ABOVE FINISHED FLOOR, WHERE MOUNTED EXPOSED AND

SUBJECT TO DAMAGE.

10. MAIN BRANCH CIRCUIT CONDUIT RUNS SHALL BE EMT, UNLESS NOTED OTHERWISE. FLEXIBLE CONDUIT OR MC CABLE MAY BE USED FOR FINAL RUN TO POWER POLE (MAXIMUM OF 10 FEET LENGTH). REFER TO SPECIFICATIONS

FOR ADDITIONAL RACEWAY RESTRICTIONS.

11. TYPE MC CABLE SHALL BE CONCEALED IN WALL AND CEILING SPACES WITH ACCESSIBLE CEILING ONLY. REFER TO

SPECIFICATIONS FOR ADDITIONAL RACEWAY RESTRICTIONS.

12. WHERE GFCI PROTECTION IS INDICATED, A GFCI TYPE RECEPTACLE SHALL BE PROVIDED AT EACH LOCATION.

LOAD SIDE PROTECTION OF DOWN STREAM DEVICES IS NOT ACCEPTABLE.

13. RECEPTACLES WITHIN 6 FEET OF SINKS AND ALL OTHER WASH BASINS SHALL BE GFCI.

14. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE POWER FEED(S) TO MECHANICAL EQUIPMENT THAT REQUIRES A POWER FEED, UNLESS OTHERWISE NOTED. COORDINATE WITH INFORMATION ON MECHANICAL

DRAWINGS AND MECHANICAL TRADES ON SITE.

15. REFER TO ARCHITECTURAL DRAWINGS FOR WALLS TO BE PROVIDED WITH INSULATION FOR ACOUSTICAL

PURPOSES.

16. FIRE-STOPPING MATERIAL SHALL BE PROVIDED FOR RACEWAY PENETRATIONS THROUGH FIRE-RATED WALLS OR

ASSEMBLIES.

17. EMPTY CONDUITS SHALL BE DEBURRED, CLEANED, TAGGED AND PROVIDED WITH A NYLON PULL STRING.

18. IN AREAS WITH GYPSUM BOARD CEILINGS, THE ELECTRICAL TRADES SHALL ROUTE CONDUIT AND POSITION PULL/JUNCTION BOXES TO ALLOW ACCESS THRU ACCESS PANELS PROVIDED BY ARCHITECTURAL TRADES, WHERE POSSIBLE. WHERE ADDITIONAL ACCESS PANELS ARE REQUIRED FOR ELECTRICAL EQUIPMENT, THE ELECTRICAL TRADES SHALL INCLUDE THE ACCESS PANEL IN THE BID. ACCESS PANEL SHALL BE INSTALLED BY THE CEILING

INSTALLER. ADDITIONAL ACCESS PANEL LOCATIONS SHALL BE APPROVED BY THE ARCHITECT.

19. IN GENERAL, ELECTRICAL DEVICES, WHICH ARE INDICATED ON THE PLAN, MAY BE SCALED AND MOUNTED TO THE NEAREST STUD EXCEPT WHERE DIMENSIONED OR ADDITIONAL LAYOUT CRITERIA IS INDICATED AT CRITICAL

LOCATIONS.

20. ELECTRICAL DEVICE OUTLETS SHALL NOT BE LOCATED BACK TO BACK WITHIN THE SAME STUD SPACE IN INTERIOR

INSULATED WALLS. ONE OF THE DEVICES SHALL BE OFFSET TO THE NEXT STUD SPACE.

21. MULTIGANG DEVICES SHALL BE GANGED UNDER SINGLE MULTIGANG COVERPLATE.

22. WHERE ELECTRICAL DEVICES ARE INDICATED ON A COLUMN, THE DEVICE SHALL BE CENTERED ON THE COLUMN

SURFACE.

23. FURNITURE LAYOUTS ARE SHOWN FOR REFERENCE ONLY. COORDINATE FINAL LOCATION OF ELECTRICAL DEVICES, FLOOR BOXES, AND FLOOR CORES WITH FINAL FURNITURE LAYOUT PRIOR TO INSTALLATION.

24. WHERE POWERED FURNITURE SYSTEMS ARE INDICATED TO BE POWERED FROM COLUMN OR HARD WALL, THE ELECTRICAL TRADES SHALL PROVIDE A BLANK COVER WITH CENTER HOLE FOR CONNECTION AND TERMINATION TO THE FURNITURE SYSTEM WHIP. FURNITURE SYSTEM WHIP, CONNECTOR AND WIRING TO FURNITURE SYSTEM WILL BE FURNISHED BY FURNITURE INSTALLER. COORDINATE EXACT TERMINATION POINT WITH THE FURNITURE SUPPLIER. COORDINATE THE PHASING/CIRCUITING AS INDICATED ON THE ELECTRICAL DRAWINGS WITH THE

FURNITURE INSTALLER FOR CONFIGURATION CONSISTENT WITH THE DESIGN INTENT.

25. WHERE POWERED FURNITURE SYSTEMS ARE INDICATED TO BE POWERED FROM POWER POLES, THE ELECTRICAL TRADES SHALL PROVIDE A JUNCTION BOX ABOVE CEILING NEAR THE TOP OF THE POWER POLE, PROVIDE FLEX CONDUIT TO EXTEND FURNITURE WIRING TO JUNCTION BOX AND PROVIDE TERMINATION TO THE FURNITURE SYSTEM CABLING. FURNITURE SYSTEM POWER POLE, CONNECTOR AND WIRING TO FURNITURE SYSTEM WILL BE FURNISHED BY FURNITURE INSTALLER. COORDINATE EXACT TERMINATION POINT WITH THE FURNITURE SUPPLIER.

COORDINATE THE PHASING/CIRCUITING AS INDICATED ON THE ELECTRICAL DRAWINGS WITH THE FURNITURE

INSTALLER FOR CONFIGURATION CONSISTENT WITH THE DESIGN CONTENT.

26. ASSUMPTIONS OF FURNITURE SYSTEM (BY OTHERS) ARE AS FOLLOWS:

A. FURNITURE IS 5 WIRE TYPE (L1, L2, L3, N & G).

B. CUBICLE FURNITURE, POWER POLES AND FURNITURE WHIPS ARE TO BE FURNISHED BY OTHERS.

C. FURNITURE SHALL UTILIZE FREE-STANDING POWER POLES WITH WHIPS TO FURNITURE CONNECTION WHERE

INDICATED ON DRAWINGS.

D. FURNITURE SHALL UTILIZE POWER POLES WHICH ARE INTEGRAL WITH FURNITURE WALLS (TEE OF CORNERS)

WHERE INDICATED ON DRAWINGS.

E. TERMINATION OF WHIP AT BOTTOM OF POWER POLE, CONNECTION OF WHIP TO FURNITURE RAIL WILL BE BY

ELECTRICAL CONTRACTOR.

27. EMERGENCY (NEC SECTION 700) WIRING SHALL BE IN SEPARATE CONDUIT FROM NON-EMERGENCY WIRING

(EXCEPT AT FINAL CONNECTION TO LIGHT FIXTURES).

28. EACH 120 VOLT BRANCH CIRCUIT PHASE CONDUCTOR SHALL BE PROVIDED WITH SEPARATE FULL SIZE NEUTRAL

CONDUCTOR.

29. 120 VOLT BRANCH CIRCUITS MAY SHARE FULL SIZE GROUND WITH UP TO 3 CIRCUITS WHICH SERVE SIMILAR LOADS.

30. WHERE ADEQUATE CIRCUIT QUANTITIES ARE NOT AVAILABLE WITHIN A DESIGNATED PANEL, BUT ARE AVAILABLE IN ANOTHER PANEL NEARBY, THE ELECTRICAL CONTRACTOR SHALL REVISE THE CIRCUITS TO THE AVAILABLE PANEL

BOARD AT NO ADDITIONAL COST.

31. PROVIDE FIELD LABELING OF BRANCH CIRCUITS AND RECEPTACLE DEVICES TO INDICATE PANEL BOARD AND

CIRCUIT NUMBER OF SOURCE. PROVIDE LABELING ON DEVICE COVER PLATE OR J-BOX COVER.

32. CONDUCTORS SIZED FOR VOLTAGE DROP THAT ARE TOO LARGE FOR LUGS SHALL BE REDUCED USING EITHER COMPRESSION PIN TERMINALS PIGTAIL ADAPTERS OR MODULAR INSULATED POWER DISTRIBUTION BLOCKS.

33. PANEL BOARD SUPPLIER SHALL PROVIDE A GROUND BAR ASSEMBLY MOUNTED ON A BAKELITE BACKING AND MOUNT TO PANEL IN SUCH A WAY AS TO INSURE AN ISOLATED GROUND CONNECTION FOR CIRCUITS.

34. FEEDER SIZES ARE BASED ON NEC 2014 ARTICLE 310.15, 250.122, AND 110.14. CONDUIT SIZES SELECTED ARE BASED ON RIGID METAL CONDUIT (UNLESS NOTED OTHERWISE) AND 40% CONDUIT FILL. CONDUIT SIZE SHALL BE ADJUSTED AS REQUIRED FOR OTHER TYPES OF CONDUIT. CONDUCTOR SIZE IS BASED ON AN AMBIENT TEMPERATURE OF 60°C AND 600V INSULATED COPPER CABLE APPLIED AT 60°C FOR TERMINATIONS RATED 100 AMPS AND LESS AND 75°C FOR TERMINATIONS RATED MORE THAN 100 AMPS. CONDUCTOR SIZE IS A MINIMUM AND DOES NOT TAKE INTO ACCOUNT VOLTAGE DROP OR DERATING. CONDUCTOR SIZE SHALL BE ADJUSTED AS REQUIRED PER NEC. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR

APPROPRIATE TYPE OF CONDUCTORS AND LUGS FOR ALL MECHANICAL EQUIPMENT.

ELECTRICAL GENERAL NOTES (ALL MAY NOT APPLY)

1. SCOPE OF WORK: ELECTRICAL DEMOLITION WORK SHALL INCLUDE DISCONNECTION OF LIGHTING FIXTURES, RECEPTACLES, WIRING, CONDUIT, BOXES, ETC. IN THE AREA OF NEW AND/OR RENOVATION CONSTRUCTION.

2. SITE SURVEY: ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMISSION OF HIS/HER BID TO EXAMINE

THE EXISTING CONDITIONS AND THE EXTENT OF THE DEMOLITION WORK.

3. SITE UTILITIES: ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REQUESTING EXISTING AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER.

ELECTRICAL CONTRACTOR IS FULLY RESPONSIBLE FOR REPAIRING ALL DAMAGED UTILITIES RESULTING FROM

CONSTRUCTION RELATED ACTIVITIES.

4. COORDINATION WITH OTHER TRADES: EXAMINE ALL DRAWINGS BY OTHER TRADES TO BE FAMILIAR WITH DEMOLITION REQUIREMENTS BY OTHER TRADES. PROVIDE ALL INCIDENTAL ELECTRICAL DEMOLITION OF AND/OR RELOCATION OF ELECTRICAL SYSTEMS TO FACILITATE THE DEMOLITION WORK FROM OTHER TRADES WHETHER

OR NOT INDICATED ON THE DRAWINGS.

5. COORDINATION: COORDINATE THE DEMOLITION WITH THE NEW WORK FOR THE EXTENT OF DEMOLITION WORK.

6. RACEWAYS: REMOVE ALL UNUSED EXPOSED CONDUIT, WIRE, RACEWAY, JUNCTION BOXES, HANGERS, AND CLAMPS BACK TO THE SOURCE PANELBOARDS. WHERE CONDUITS ARE CONCEALED IN WALL CAVITIES, CUT AND REMOVE THE CONDUITS ABOVE EXISTING WALL LEADING INTO AN ACCESSIBLE CEILING OR TRUSS SPACE. REMOVE

SURFACE MOUNTED ELECTRICAL DEVICES, BOXES, AND RELATED CONDUITS.

7. PANEL SCHEDULES: PROVIDE UP-TO-DATE PANEL SCHEDULES FOR ALL PANELS DESIGNATED AS EXISTING TO REMAIN. SHOW ACTIVE CIRCUITS AND LOADS. IDENTIFY CONDUITS AND LABEL CIRCUITS FOR FUTURE

RELOCATION.

8. CONDUIT STATUS: FIELD VERIFY STATUS OF CONDUITS IN THE CEILING SPACE AND DETERMINE IF CONDUITS ARE TO REMAIN OR BE REMOVED. WHERE APPLICABLE AND NOT SPECIFICALLY INDICATED OTHERWISE, EXISTING IN- PLACE CONDUITS ABOVE CEILINGS OR IN WALLS, JUNCTION BOXES, PULL BOXES, AND HANGERS ABOVE CEILINGS, TRUSS SPACE, OR IN WALLS MAY BE RE-USED FOR NEW WIRING. COMPLY WITH CONDUIT FILL REQUIREMENTS

LISTED IN THE NEC.

9. ACTIVE CIRCUITS: EXISTING ACTIVE CIRCUITS IN WORK AREAS TO REMAIN. WHERE REMOVAL OF CONDUIT AND WIRING AFFECTS THE OPERATION UPSTREAM AND/OR DOWNSTREAM OF ELECTRICAL EQUIPMENT, WHICH IS NOT INDICATED TO BE REMOVED, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN AND PROVIDE ALL REQUIRED CONDUITS AND WIRING TO RESTORE THE UPSTREAM AND/OR DOWNSTREAM CONNECTIONS OF ELECTRICAL EQUIPMENT TO ITS NORMAL OPERATION. ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WITH

OWNER AND ASSOCIATED PARTIES.

10. FEEDERS: DISCONNECT AND REMOVE FEEDERS FROM THE ARCHITECTURAL AND MECHANICAL EQUIPMENT TO BE REMOVED. COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS AND CONTRACTORS FOR FULL

SCOPE OF WORK. REMOVE ALL DISCONNECTS, JUNCTION BOXES, AND CONTROL STATIONS.

11. LOW VOLTAGE CABLING: REMOVE UNUSED DATA/COMMUNICATION CONDUITS AND CABLING COMING FROM TELEPHONE AND DATA CLOSETS. CONDUITS THAT ARE EXISTING TO REMAIN SHALL BE TAGGED AS SUCH.

12. SUPPORT: RE-SUPPORT ITEMS WHERE WALLS AND SUPPORTS ARE SCHEDULED FOR REMOVAL.

13. PROTECTION: PROTECT EXISTING ITEMS TO REMAIN FROM DAMAGE BY OTHER DEMOLITION ACTIVITIES.

14. TEMPORARY POWER: FURNISH AND INSTALL TEMPORARY FEEDS FOR EXISTING ITEMS AFFECTED BY

CONSTRUCTION AND REQUIRED TO BE OPERATIONAL DURING THE CONSTRUCTION PERIOD.

15. MATERIAL: MATERIAL INCLUDING, BUT NOT LIMITED TO, WIRING DEVICES, CONDUIT, WIRING, JUNCTION BOXES, ETC.

THAT IS REMOVED SHALL BECOME PROPERTY OF THE VA ELECTRICAL SHOP. THE VA ELECTRICAL SHOP TO INSPECT AND KEEP ANY MATERIAL THAT ARE STILL USABE, PRIOR TO CONTRACTOR DISPOSING OF THESE

MATERIALS.

16. SALVAGED EQUIPMENT: ELECTRICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO, PANELBOARDS, TRANSFORMERS, LIGHT FIXTURES, DISCONNECT SWITCHES, CONTROL PANELS, ETC. THAT IS REMOVED SHALL BE

CLEANED AND RETURNED TO OWNER, UNLESS OWNER ELECTS TO DISPOSE OF THIS EQUIPMENT.

ELECTRICAL GENERAL NOTES (DEMOLITION WORK)

(ALL MAY NOT APPLY)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:0

P

M

EO001

DEMOLITION AND GENERAL

NOTES

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

187216

L

M

M.4

N

M.1

13.3

A

B

13.2

HH

FF

JJ

GG

KK

12 3 4 5 6 7 8 9 10 11 12 13 14 15

ED402

ED403

ED404

ED402

ED401

10.8

TEMPORARY

PHARMACY

(PHASE 1) OPEN

OFFICE AND

AUDIOLOGY

(PHASE 3)

PHARMACY

(PHASE 2)

URGENT CARE

(PHASE 4)

SHADE INDICATES

APPROXIMATE

AREA OUT OF

SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:0

P

M

ED101

DEMOLITION PLAN GROUND

FLOOR

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

EP405 3/32" = 1'-0"

1 DEMOLITION PLAN GROUND FLOOR COMPOSITE

GENERAL NOTES :

1. REFER TO SHEET EO000, EO001, EY000 AND FA000 FOR

SYMBOLS, DEMOLITION AND GENERAL NOTES RESPECTIVELY.

187216

NOT TO SCALE

KEY PLAN - GROUND FLOOR

F

P

P

P

P

P

J J

J

J

J

W F

W F

W F

F

F

F

C R

F

F F

F F

F

H

J

L

M

M.4

N

M.1

HH

JJ

GG

KK

2 3 4 5 6 7 8

0015E

0015A

S6

VEST

0020E

0015E

0015A

S6

VEST

0020E

0015E

0015A

S6

VEST

0020E

(TYP)

(TYP)

HVAC

0015E

CONTROLLED

SUBSTANCE

0015A

STAIR

S6

VEST

OF-002

SHELL

OF-001

PHARMAC

HVAC

0020E

HOUSEKEEPING

(R)

(ER)

(R)

(TYP)

(ER) (ER)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(R)

(R)

(TYP)

(TYP)

(TYP)

(TYP)

(ER)

(ER)(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(E R

(ER)

(ER)

(ER)

(ER)

(R)

(R)

(R)

(R)

(R)

(R)

(R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

VESTVESTVESTVEST

OF-003

(ER)

(ER)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(R) (R) (R)

(R)

(R)

(R)

(R) (R)

(R) (R)(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(ER)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

(R)

(R)

(ER)

(ER)(ER)(ER)

(ER)(ER)

(ER)

(ER)

(ER)

(ER)

(E R)

(ER)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(ER)

(ER)

EXIT PASSAGEWAY

CO-1

(ER)

(R)

(R)

(ER)

(ER)

(ER) (ER)

(R)

(R)

(R)

(R)(R)

EP405

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:0

P

M

ED401

DEMOLITION LARGE SCALE VIEW-

PHARMACY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

ED101 1/4" = 1'-0"

1 DEMOLITION PLAN GROUND FLOOR - PHARMACY

GENERAL NOTES :

DEMOLITION KEY NOTES :

1. REMOVE SECURITY CAMERAS AND RETAIN FOR RE-USE.

2. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES,

SMOKE DETECTORS, STROBE, SPEAKERS, PULL BOX AND

RETAIN FOR RE- USE. DISCONNECT POWER WIRING BRANCH

CIRCUITRY AND BRING IT BACK TO SOURCE.

3. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.

4. ELECTRICAL PANELS TO REMAIN.

5. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,

SWITCHES. REFER TO ARCHITECTURAL DRAWINGS FOR

DETAILS OF ROOMS, CEILINGS TO BE REMOVED. DISCONNECT

POWER WIRING BRANCH CIRCUITRY AND BRING IT BACK TO

SOURCE.

187216

NOT TO SCALE

KEY PLAN - PHARMACY

GENERAL NOTES :

1. REFER TO SHEET EO000, EO001 AND FA000 FOR SYMBOLS,

DEMOLITION AND GENERAL NOTES RESPECTIVELY.

DEMOLITION KEY NOTES : #

FACP

F

F

P

P

P P

F

F

F

P P P

P

P

P

PP

P

P

P P

P

P

P

P

F F

F

P

P

P P

P

B

FF

GG

2 3 4 5 6 7 8

OFFICE

OFFICE

EXAM

OFFICE

0074 SUB WAITING

OFFICE

I.T

OFFICE

HSK

ELEC.

SECURITY OFFICE

ELEV.

E3

TOILET

STAFF LONGE/

LOCKER ROOM

WAITING

C03

PIPE

0014E

OFFICE

STOR.

MALE

FEMALE

OFFICE

MALE

FEMALE

HVAC

0017A

ELEV.

E1

ELEV.

MACH.

0018E

ELEV.

E2

PATIENT

FUNDS

AGENT

CASHIER

STOR.

0016A

STAIR

S1

(R)

(R)

(ER)

(ER)

(ER)

(ER)

(R)

(R)

(R)

EXISTING FIRE ALARM

CONTROL PANEL

TO REMAIN

A-8

(R)

(R)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)(ER)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)(R)

(R)

(R)

(R) (R) (R)

(R)

(R)(R)(R)

(R)

(R)

(TYP)

(TYP)

(TYP)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

(R)

CORRIDOR

C02

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

EXISTING IT ROOM

EXISTING

ELECTRICAL ROOM

(R)

(R)(R)

(R)

(R)

(ER)

(ER)

(ER) (ER)

(R)

(R)

(R)

(TYP)

(TYP)

(TYP)

(ER)

(ER)

(ER)

(R)

(ER)

(ER)

(R)

(ER)

(ER)

(ER)(ER)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(ER)

A

7 8 9 10

STAIR

S5

ADMISSIONS

WAITING ROOM

(ER)

(R)

(R)

(R)

(TYP)

(TYP)

(ER)(ER)(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(R)

VESTIBULE

(ER) (ER) (ER)

(ER)

(ER)

(ER)

(R)

(R)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(TYP)

(TYP)

(TYP)

(TYP)

(R)

(R)

(R)

(R)

(R)

RECEPTION

(R)

(R)

(R)

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:0

P

M

ED402

DEMOLITION LARGE SCALE VIEW -

WAITING & ENTRANCE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

ED101 1/4" = 1'-0"

1 DEMOLITION PLAN GROUND FLOOR - PHARMACY WAITING

SCALE:

NORTH

ED101 1/4" = 1'-0"

2 DEMOLITION PLAN GROUND FLOOR - SOUTH ENTRANCE

GENERAL NOTES :

DEMOLITION KEY NOTES :

1. REMOVE SECURITY CAMERS AND RETAIN FOR RE-USE.

2. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES,

SMOKE DETECTORS, STROBE, SPEAKERS, PULL BOX AND

RETAIN FOR RE- USE.DISCONNECT POWER WIRING BRANCH

CIRCUITRY AND BRING IT BACK TO SOURCE.

3. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.

4. ELECTRICAL PANELS TO REMAIN.

5. REMOVE PANEL (E)A-8 IN WAITING-C03 AND RETURN TO OWNER

FOR RE-USE. REMOVE ALL ASSOCIATED CONDUITS AND

CONTROL WIRING BACK TO SOURCE.

6. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,

SWITCHES. REFER TO ARCHICHETURAL DRAWINGS FOR

DETAILS OF ROOMS, CEILINGS TO BE REMOVED. DISCONNECT

POWER WIRING BRANCH CIRCUITRY AND BRING IT BACK TO

SOURCE.

7. REMOVE ALL EXISTING PUBLIC ADDRESS SPEAKERS

DESIGNATED AS (R) CLEAN AND SAFE KEEP FOR

REINSTALLATION.

8. EXISTING PHARMACY PAGING SYSTEM AMPLIFIER LOCATED IN

CLOSET C03A, MICROPHONE AND PAGING SPEAKERS LOCATED

IN WAITING AREA SHALL BE DISCONNECTED AND REMOVED.

SYSTEM SHALL BE CLEANED, SAFE KEPT AND REUSED IN

TEMPORARY PHARMACY AND REUSED AGAIN IN PERMANENT

PHARMACY.

187216

NOT TO SCALE

KEY PLAN - WAITING AND ENTRANCE

1. REFER TO SHEET EO000, EO001 AND FA000 FOR SYMBOLS,

DEMOLITION AND GENERAL NOTES RESPECTIVELY.

FF

P

F

F

P

AOM

P

P

J

J

J

F

P

P

P

P

P

H

J

L

M

M.4

N

M.1

13.3

HH

JJ

GG

KK

8 9 10 11 12 13 14 15

HVAC

0021E

OFFICE

OFFICE

VENDING

EXAM SOUND

BOOTH

EXAM SOUND

BOOTH

OFFICE

CORRIDOR

C07

SHELL

OG-001

TYPICAL

(ER)

(ER)

(ER)

(ER)(ER)

(ER)

(ER)

(ER)

(R)

(R)

(R)

(R)

(ER)

(ER)

(ER)

(R)

(R)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

CORRIDOR

C05

EXIT PASSAGEWAY

CO-2

SECRETARY

EXAM SOUND BOOTH

CHIEF

HVAC

0042E

(ER)

(ER)

(R)

(R)(R)

(R) (R) (R)

(R)(R)(R)

(R) (R)

(R) (R) (R)

(R) (R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(TYP)

(TYP)

(ER)

(ER)

(R)

(R)

(R)

(R)

(ER)

(R)

(ER)

(TYP)

(ER)

(R)

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:1

P

M

ED403

DEMOLITION LARGE SCALE VIEW -

OPEN OFFICE AND AUDIOLOGY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

ED101 1/4" = 1'-0"

1 DEMOLITION PLAN GROUND FLOOR - OPEN OFFICE AND AUDIOLOGY

GENERAL NOTES :

DEMOLITION KEY NOTES :

1. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES.

RETAIN FOR RE- USE.

2. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.

3. ELECTRICAL PANELS TO REMAIN.

4. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,

SWITCHES ETC. TO BE DEMOLISHED. REFER TO

ARCHICHETURAL DRAWINGS FOR DETAILS OF ROOMS,

CEILINGS TO BE REMOVED. DISCONNECT POWER WIRING

BRANCH CIRCUITRY AND BRING IT BACK TO SOURCE.

5. REMOVE ALL EXISTING PUBLIC ADDRESS SPEAKERS

DESIGNATED AS "R" CLEAN AND SAFE KEEP FOR

REINSTALLATION.

NOT TO SCALE

KEY PLAN - OPEN OFFICE AND AUDIOLOGY

187216

GENERAL NOTES :

DEMOLITION KEY NOTES : #

1. REFER TO SHEET EO000,EO001 AND FA000 FOR SYMBOLS,

DEMOLITION AND GENERAL NOTES RESPECTIVELY.

100% BID DOCUMENTS

(R)

FF

F

F

SR

CB

SR

CB

SR

CB

SR

CB

S R

C B

S R

C B

F

S R

C B

S R

C B

S R

C B

S R

C B

SR

CB

SR

CB

SR

CB

S R

C B

F

F

F

P

P

P

P

P

P

F

F

P P

P

P

P

P

PP

P

P

P

P

P P

13.3

A

B

13.2

FF

GG

8 9 10

11 12 13

14 15

CORRIDOR

C07

WAITING

PROSTHETICS

TREATMENT

(ER)

(ER)

(R)

(R)

(R)

ER

R

(R)

(R)

ER

(ER)

RECEPTION

PATIENT

INFORMATION

EQUIP.

STAFF LOUNGE

TOILET

ROOM

TREATMENT

CORRIDOR

C01

CORRIDOR

C011

CORRIDOR

C012

CORRIDOR

C06

STORAGE

0110 TRIAGE

TRIAGE

TRIAGE

OFFICE

EXAM

EXAM

EXAM

TOILET

0122A

EXAM

NURSE

STATION

IMMEDIATE CARE

OFFICE

0103A

TELE

0050E

OFFICE

RECORDS

HVAC

0050A

MEN'S

WOMEN'S

CORRIDOR

C09

CORRIDOR

C08

RECOVERY

TOILET

0092A

DRESSING ROOM

SOILED UTILITY

(R)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

(TYP)

(TYP)

(TYP)

CORRIDOR

C013

HSK

CORRIDOR

C010

CORRIDOR

C08

STOR.

STAIR

S2

(R)

(R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)(R)

(R) (R)

(R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(R)

(R)

(R)(R) (R)

(R) (R) (R)

(R)

(R)

(R)

(R)

(R)

(R) (R) (R)

(R)

(R)

(R)

(R)

EY407

(TYP)

(R)

(R)

(R)

(R)

(R) (R)

(R)

(R)

(R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R) (R)(R)

(R)

(R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R) (R) (R)

(R) (R)

(R) (R)

(R)

(R) (R)

(R)

(TYP.)

(R)

(R)

(R)

(R)

(ER) (ER)(ER)

(R)

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:5

:4

P

M

ED404

DEMOLITION LARGE SCALE VIEW -

URGENT CARE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

ED101

1/4" = 1'-0"

1 DEMOLITION PLAN GROUND FLOOR - URGENT CARE

GENERAL NOTES :

DEMOLITION KEY NOTES :

1. REMOVE SECURITY CAMERS AND RETAIN FOR RE-USE.

2. REMOVE FIRE ALARM INITIATING AND NOTIFICATION DEVICES.

RETAIN FOR RE- USE.

3. REMOVE LUMINAIRES, CLEAN AND STORE FOR RE-USE.

4. ELECTRICAL PANEL A-1 AND A-2 ARE RELOCATED TO NEW

LOCATION. REMOVE ALL ASSOCIATED CONDUITS AND

CONTROL WIRING BACK TO SOURCE.

5. ELECTRICAL PANELS TO REMAIN.

6. REMOVE ALL MISCELLANEOUS POWER RACEWAYS, WIRE,

SWITCHES ETC. TO BE DEMOLISHED. REFER TO

ARCHICHETURAL DRAWINGS FOR DETAILS OF ROOMS,

CEILINGS TO BE REMOVED. DISCONNECT POWER WIRING

BRANCH CIRCUITRY AND BRING IT BACK TO SOURCE.

7. CONTRACTOR SHALL REMOVE DOOR MAGNATIC DOOR

HOLDER, SMOKE DETECTORS, STROBE, SPEAKER, PULL BOX

AND POWER WIRING BRANCH CIRCUITRY BACK TO SOURCE.

8. REMOVE ALL EXISTING PUBLIC ADDRESS SPEAKERS

DESIGNATED AS "R" CLEAN AND SAFE KEEP FOR

REINSTALLATION.

NOT TO SCALE

KEY PLAN - URGENT CARE

187216

GENERAL NOTES :

DEMOLITION KEY NOTES : #

1. REFER TO SHEET EO000, EO001 AND FA000 FOR SYMBOLS,

DEMOLITION AND GENERAL NOTES RESPECTIVELY.

REF.REF.

REF.

REF.

UP

H

J

L

M

M.4

N

M.1

13.3

A

B

13.2

HH

FF

JJ

GG

KK

12 3 4 5 6 7 8 9 10 11 12 13 14 15

EL402

EL403

EL404

EL402

EL401

TEMPORARY

PHARMACY

(PHASE 1) OPEN

OFFICE AND

AUDIOLOGY

(PHASE 3)

PHARMACY

(PHASE 2)

URGENT CARE

(PHASE 4)

SHADE INDICATES

APPROXIMATE

AREA OUT OF

SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:2

P

M

EL101

LIGHTING PLAN GROUND FLOOR

COMPOSITE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

EP405 3/32" = 1'-0"

1 LIGHTING PLAN GROUND FLOOR COMPOSITE

GENERAL NOTES :

1. REFER TO SHEET EO000 AND EO001 FOR SYMBOLS, DEMOLITION

AND GENERAL NOTES.

2. REFER TO LUMINAIRE SCHEDULE ON SHEET EL701 FOR THE

LUMINAIRE DESCRIPTION AND MOUNTING HEIGHTS, UNLESS

OTHERWISE NOTED.

187216

NOT TO SCALE

KEY PLAN - GROUND FLOOR

REF. REF.

D D

OS

D D

3D

D

D

D

D

OS

OS

OS

OS

OS

3D

OS

OS

OS

OS

OS

OS

D

OS

OS

OS

OS

H

J

L

M

M.4

N

M.1

HH

JJ

GG

KK

2 3 4 5 6 7 8

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2L1

LP-CB6;2

L1

LP-CB6;2

EL1

EP-CB1;2

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

EL1

EP-CB2;14

L1

LP-CB6;2

EL1

EP-CB2;14

EL1

EP-CB2;14

EL1

EP-CB2;14

L1

LP-CB6;2

EL1

EP-CB2;14

L1

LP-CB6;2

L1

LP-CB6;2 EL1

EP-CB2;14

L1

LP-CB6;2

L1

LP-CB6;2

EL1

EP-CB2;14

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

EL1

EP-CB2;14

L1

LP-CB6;2

EL1

EP-CB2;14

EL1

EP-CB2;14

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

EL1

EP-CB2;14

L1

LP-CB6;2

L1

LP-CB6;2

L1

LP-CB6;2

LP-CB6

EL1

EP-CB2;14

EL6

(R)EL6

(ER)

MDP-4

RP-CB6

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)(ER)

(ER)

(ER)

X1

E…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .