515-18-109 Bid Drawings - Signed_Part4.pdf

PDF 15 MB Posted

Attached to
Z1DA--Renovate Outpatient Pharmacy & Urgent Care 515-18-109
Solicitation number
36C25020B0058
Issued by

About this file

This federal contract opportunity solicitation is for renovation services for an outpatient pharmacy and urgent care facility located at the Battle Creek Healthcare System in Battle Creek, Michigan. The solicitation number is 36C25020B0058 and seeks bids to furnish all labor, materials, supervision, equipment, tools and other necessary resources for the project according to contract specifications, drawings, terms and conditions. Site visits are scheduled and bids must be submitted in sealed envelopes to the Department of Veterans Affairs Network 10 Contracting Office by September 10, 2020 at 2:00PM. The place of performance is 5500 Armstrong RD, Battle Creek, Michigan 49037. This procurement is fully set aside for Service Disabled Veteran Owned Small Businesses and has a $39.5 million small business size standard. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF.REF.

REF.

REF.

UP

H

J

L

M

M.4

N

M.1

13.3

A

B

13.2

HH

FF

JJ

GG

KK

12 3 4 5 6 7 8 9 10 11 12 13 14 15

FA401

FA402

FA403

FA404

FA402

10.8

TEMPORARY

PHARMACY

(PHASE 1) OPEN

OFFICE AND

AUDIOLOGY

(PHASE 3)

PHARMACY

(PHASE 2)

URGENT CARE

(PHASE 4)

SHADE INDICATES

APPROXIMATE

AREA OUT OF

SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:4

P

M

FA101

FIRE DETECTION AND ALARM

GROUND FLOOR COMPOSITE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

EP405 3/32" = 1'-0"

1 FIRE ALARM PLAN GROUND FLOOR COMPOSITE

GENERAL NOTES :

1. REFER TO SHEET FA000 FOR SYMBOLS AND

GENERAL NOTES.

187216

NOT TO SCALE

KEY PLAN - GROUND FLOOR

100% BID DOCUMENTS

Revisions: Date:

REF. REF.

P

P

P

P

P

W F

W F

W F

H

J

L

M

M.4

N

M.1

HH

JJ

GG

KK

2 3 4 5 6 7 8

15cd

15cd

30cd

CONFERENCE RM

BREAK RM

0225 STAFF TLT

HAC

PHARM. STORAGE

MECHANICAL

WORK STATIONS

OFFICE

OFFICE

RECEIVING

INV. CONTROL

MANAGER

MAIL-OUT

DISPENSING WINDOWS

FILLING

CALL ROOM

VAULT

PHARMACY WORK RM

MECH

(TYP)

(TYP)

75cd

15cd

15cd

75cd

15cd

75cd

75cd

(R)

(ER)(ER) (ER)

(ER)

(ER)(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(R)

(R)

(R)

(R)

(R)

(TYP)

(TYP)

(ER)

(ER)

15cd

15cd

15cd

15cd

15cd

STAIR

S6

Space

021G

15cd

15cd

Space

021H

EXIT PASSAGEWAY

01228

HOUSE KEEPING

HVAC

0020E

EP405

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:5

P

M

FA401

FIRE ALARM LARGE SCALE VIEW -

PHARMACY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

FA101 1/4" = 1'-0"

1 FIRE ALARM PLAN GROUND FLOOR - PHARMACY

187216

GENERAL NOTES :

1. REFER TO SHEET FA000 FOR SYMBOLS AND GENERAL

NOTES.

2. EXISTING WORK IS SHOWN WITH LIGHT LINE WEIGHT.

NEW WORK IS SHOWN WITH HEAVY LINE WEIGHT.

3. FIRE ALARM DEVICES ( NOTIFICATION AND INITIATION

DEVICES) SHALL BE ADDRESSABLE AND CONNECTED TO

EXISTING FIRE ALARM CONTROL PANEL THROUGH SIGNAL

LINE OF CIRCUIT (SLC).

4. SPEAKERS/HORN WITH STROBE SHALL BE 15db ABOVE

AMIENT NOISE LEVEL.

SHEET NOTES :

1. INSTALL FIRE ALARM PULL STATIONS NEXT TO EXIT DOOR.

CONNECT TO FIRE ALARM SYSTEM LOOP .

2. INSTALL FIRE ALARM NOTIFICATION DEVICES AS INDICATED.

CONNECT IT TO EXISTING AND/OR NEW ADDRESSABLE SYSTEM

LOOP PER NFPA 72.

3. CONTRACTOR SHALL EXTEND WIRING BRANCH CIRCUITRY TO NEW

LOCATION OF RELOCATED DEVICES AS NECESSARY.

NOT TO SCALE

KEY PLAN - PHARMACY

FACP

P

P

P

P

B

FF

GG

2 3 4 5 6 7 8

75cd

30cd

CONSULT

CONSULT

CONSULT

HALL

CONSULT / DISPENSING

PHARMACY WAITING

CONSULT

CORRIDOR

C02

VEST. / BOX BREAK

DOWN

NF AND PENDING

CORRIDOR

C014

ELEC.

15cd

15cd

(TYP)

(ER)

(R)

(TYP)

(R)

(R)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER) (ER) (ER)

(ER)

I.T.

EXISTING IT ROOM EXISTING IT ROOM

EXISTING ELECTRICAL ROOM

15cd

(ER)

(ER)

EXIT PASSAGEWAY

01228

STOR.

016A

STAIR

S1

ELEV. MACH.

0018E

ELEV.

E2

ELEV.

E1

HVAC

0017E

HOUSE KEEPING

15cd

30cd

(ER)

A

7 8 9 10

75cd

UC WAITING

GENERAL WAITING

WALK-IN ENTRANCE

30cd

(TYP)

(TYP)

(R)

(ER)

(R)

(TYP)

CORRIDOR

C014

(TYP)

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:5

P

M

FA402

FIRE ALARM LARGE SCALE VIEW -

WAITING AND ENTRANCE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

FA101 1/4" = 1'-0"

1 FIRE ALARM PLAN GROUND FLOOR - PHARMACY WAITING

SCALE:

NORTH

FA101 1/4" = 1'-0"

2 FIRE ALARM PLAN GROUND FLOOR - SOUTH ENTRANCE

187216

SHEET NOTES :

1. INSTALL FIRE ALARM PULL STATIONS NEXT TO EXIT DOOR.

CONNECT TO FIRE ALARM SYSTEM LOOP .

2. INSTALL FIRE ALARM NOTIFICATION DEVICES AS INDICATED.

CONNECT IT TO EXISTING ADDRESSABLE SYSTEM LOOP.

3. CONTRACTOR SHALL EXTEND WIRING BRANCH CIRCUITRY TO NEW

LOCATION OF RELOCATED DEVICES AS NECESSARY.

GENERAL NOTES :

1. REFER TO SHEET FA000 FOR SYMBOLS AND GENERAL

NOTES.

2. EXISTING WORK IS SHOWN WITH LIGHT LINE WEIGHT. NEW

WORK IS SHOWN WITH HEAVY LINE WEIGHT.

3. FIRE ALARM DEVICES ( NOTIFICATION AND INITIATION

DEVICES) SHALL BE ADDRESSABLE AND CONNECTED TO

EXISTING FIRE ALARM CONTROL PANEL THROUGH SIGNAL

LINE OF CIRCUIT (SLC).

4. SPEAKERS/HORN WITH STROBE SHALL BE 15db ABOVE

AMIENT NOISE LEVEL.

NOT TO SCALE

KEY PLAN - WAITING AND ENTRANCE

P

AOM

P

P

H

J

L

M

M.4

N

M.1

13.3

HH

JJ

GG

KK

8 9 10 11 12 13 14 15

30cd

75cd

15cd

75cd

15cd

CORRIDOR

C05

CORRIDOR

C03

30cd

(R)

(ER)

(R)

(R)

(R)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER) (ER)

(ER)

(ER)

(ER)

(ER)

15cd

15cd

15cd

15cd

15cd

CORRIDOR

C01

UC BREAK RM AND

LOCKERS

ON-CALL TLT / SHOWER

0097B

AUDIOLOGY CLEAN

STORAGE

CORRIDOR

C03

AUDIOLOGY EXAM

AUDIOLOGY AND UC

OFFICES

MECH

MECH

AGENT CASHIER

0051A

VAULT

0051B

HVAC

021E

PATIENT FUNDS

OFFICE

OFFICE

(ER)

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:2

:5

P

M

FA403

FIRE ALARM LARGE SCALE VIEW -

OPEN OFFICE AND AUDIOLOGY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

FA101 1/4" = 1'-0"

1 FIRE ALARM PLAN GROUND FLOOR - OPEN OFFICE AND AUDIOLOGY

187216

SHEET NOTES :

1. INSTALL FIRE ALARM NOTIFICATION DEVICES AS INDICATED.

CONNECT IT TO EXISTING ADDRESSABLE SYSTEM LOOP.

2. CONTRACTOR SHALL EXTEND WIRING BRANCH CIRCUITRY TO

NEW LOCATION OF RELOCATED DEVICES AS NECESSARY.

1(TYP)

(TYP)

GENERAL NOTES :

1. REFER TO SHEET FA000 FOR SYMBOLS AND GENERAL

NOTES.

2. EXISTING WORK IS SHOWN WITH LIGHT LINE WEIGHT. NEW

WORK IS SHOWN WITH HEAVY LINE WEIGHT.

3. FIRE ALARM DEVICES ( NOTIFICATION AND INITIATION

DEVICES) SHALL BE ADDRESSABLE AND CONNECTED TO

EXISTING FIRE ALARM CONTROL PANEL THROUGH SIGNAL

LINE OF CIRCUIT (SLC).

4. SPEAKERS/HORN WITH STROBE SHALL BE 15db ABOVE

AMIENT NOISE LEVEL.

NOT TO SCALE

KEY PLAN - OPEN OFFICE AND AUDIOLOGY

2 (TYP)

UP

P

P

P

P

P

P

P

13.3

A

B

13.2

FF

GG

8 9 10

11 12 13

14 15

CORRIDOR

C011

15cd

CORRIDOR

C011

NURSE MANAGER

EQUIP. STORAGE

LINEN

STOR.

CORRIDOR

C06

STAFF TLT

STAFF TLT

STORAGE

ON-CALL

0097A

HAC

EXAM / FLEX M.H.

M.H. TLT

EXAM / FLEX M.H.

EXAM

SOILED

EXIST. IT CLOSET

CORRIDOR

C010

CORRIDOR

C012

ELECTRICAL CLOSET

ELECTRICAL CLOSET

GAS - EMPTY AND

IN-USE

OFFICE

MECH

0112A

PROCEDURE

0111A

PROCEDURE

0110A

STOR.

0110B

EXAM

EXAM

EXAM

PATIENT TLT

CLEAN

MED

MH EXAM

MH EXAM

TRIAGE

RECEPTION

0103A

PHOTO

VAULT

0103B

TRIAGE

ISO / PATIENT TOILET

ISO EXAM

PROCEDURE ROOM

VESTIBULE

C09

2 (TYP)

2 (TYP)

30cd

3 (TYP)

GENERAL NOTES :

5. PROVIDE TAMPERED PROOF FIRE ALARM NOTIFICATION

DEVICES IN MENTAL HEALTH ROOMS / M.H. TOILET.

SHEET NOTES :

1. INSTALL FIRE ALARM PULL STATIONS NEXT TO EXIT DOOR.

CONNECT TO FIRE ALARM SYSTEM LOOP.

2. INSTALL FIRE ALARM NOTIFICATION DEVICES AS INDICATED.

CONNECT IT TO EXISTING ADDRESSABLE SYSTEM LOOP.

3. CONTRACTOR SHALL EXTEND WIRING BRANCH CIRCUITRY TO NEW

LOCATION OF RELOCATED DEVICES AS NECESSARY.

(TYP)

15cd

1. REFER TO SHEET FA000 FOR SYMBOLS AND GENERAL

NOTES.

2. EXISTING WORK IS SHOWN WITH LIGHT LINE WEIGHT. NEW

WORK IS SHOWN WITH HEAVY LINE WEIGHT.

3. FIRE ALARM DEVICES ( NOTIFICATION AND INITIATION

DEVICES) SHALL BE ADDRESSABLE AND CONNECTED TO

EXISTING FIRE ALARM CONTROL PANEL THROUGH SIGNAL

LINE OF CIRCUIT (SLC).

4. SPEAKERS/HORN WITH STROBE SHALL BE 15db ABOVE

AMIENT NOISE LEVEL.

(ER)

(R)

(R)

(R)

(ER)

(R)

(R)

(R)

(R)

30cd

15cd

(TYP)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(R)

(ER)

(ER)

(R)

EY407

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd 15cd

15cd

15cd15cd

SHOWER

0106A

CORRIDOR

C013

NURSE

0135A

NURSE / DICTATION

GAS - FULL

CORRIDOR

C05

CORRIDOR

C06CORRIDOR

C06

CORRIDOR

C014

(TYP)

15cd 15cd

15cd

15cd

(ER)

(TYP)

1 (TYP)

(TYP)

LEGEND:

(ER) - EXISTING TO REMAIN

(R) - RELOCATED

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e \R e v it \1

E

C

E N

T R

A L rv t_ p h e ro h a lli .r v t

/1

/2

:5

:5

P

M

FA404

FIRE ALARM LARGE SCALE VIEW -

URGENT CARE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/2020 M. Sabapathy P. Herohalli

100% BID DOCUMENTS

PART. SPRINKLERED

SCALE:

NORTH

FA101

1/4" = 1'-0"

1 FIRE ALARM PLAN GROUND FLOOR - URGENT CARE

187216

NOT TO SCALE

KEY PLAN - URGENT CARE

H

J

L

M

M.4

N

M.1

13.3

A

B

C

DD

3.8 4.9 5.3 5.7 6.5 11.9

EE

HH

FF

JJ

GG

KK

1 2 3 4 5 6

8 9

11 12 13 14 15

SHADED AREAS ARE NOT INCLUDED IN SCOPE OF WORK

RELOCATE 4" FP

PIPE UP TO

UNDERSIDE OF

STEEL, ROUTE

BETWEEN

JOISTS/BEAMS AS

MUCH AS

POSSIBLE

(E) FIRE MAIN

HATCHED AREA NOT CURRENTLY SPRINKLERED - EXTEND FIRE SUPPRESSION TO THESE AREA, PER NOTES

REMAINING AREA CURRENTLY SPRINKLERED - REWORK PER SCOPE OF WORK, SEE NOTES

MECH

STAFF TLT

CLOSET

0107A

PROC RM STOR.

0110B

GAS - FULL

STAFF TLT

ON-CALL

0097A

GENERAL WAITING

CONSULT

PROCEDURE

0110A

INV. CONTROL

MANAGER

RECEIVING

MAIL-OUT

HVAC

021E

HVAC

0017E

STAIR

S5

MECH

OFFICE

OFFICE

OFFICE

OFFICE

EXAM

OFFICE

OFFICE

0074A

OFFICE

STOR.

CUSTOMER SERVICE

OFFICE

STAIR

S3

HSK

ELEC.

TOILET

0078A

SECURITY OFFICE

ELEV.

E3

MALE

STOR.

016A ELEV. MACH.

0018E

HVAC

0020E

STOR.

CHIEF

HVAC

0042E

EXAM SOUND BOOTH

TREATMENT

PROSTHETICS

STOR.

NURSE MANAGER

TRIAGE

0105A

CLOSET

0111B

NEW VESTIBULE

C09

ELECTRICAL CLOSET

PATIENT FUNDS

HALL

DISPENSING WINDOWS

FEMALE

OFFICE

FEMALE

MALE

CONSULT

STAFF LOUNGE/

LOCKER ROOM

CORRIDOR

C04

OFFICE

I.T.

OFFICE

HOUSE KEEPING

STORAGE

OFFICE

OFFICE

EXAM SOUND BOOTH

STAIR

S6

AUDIOLOGY CLEAN

HAC

CONSULT

CONSULT

EXIST. IT CLOSET

SOILED

CORRIDOR

C08

ELECTRICAL CLOSET

GAS - EMPTY AND

IN-USE

TRIAGE

MH EXAM

WALK-IN ENTRANCE

SUB WAITING

CORRIDOR

C015

WAITING

PROCEDURE

0111A

OFFICE

EXIT PASSAGEWAY

01228

EXAM SOUND BOOTH

VAULT

MECH

ELEV.

E1

ELEV.

E2

CORRIDOR

C02

HAC

PHARMACY WAITING

VEST. / BOX BREAK

DOWN

SHOWER

0105B

UC BREAK RM AND

LOCKERS

CONSULT / DISPENSING

CORRIDOR

C01

VAULT

0051B

LINEN

EQUIP. STORAGE

PHOTO

VAULT

0103B

CORRIDOR

C06

CORRIDOR

C05

CORRIDOR

C014

UC WAITING

FILLING

CALL ROOM

AGENT CASHIER

0051A

ON-CALL TLT / SHOWER

0097B

STAFF TLT

PROCEDURE ROOM

WORK STATIONS

OFFICE

RECEPTION

0103A

ISO EXAM

ISO / PATIENT TOILET

BREAK RM

AUDIOLOGY EXAM

AUDIOLOGY AND UC

OFFICES

CORRIDOR

C012

PHARM. STORAGE

MECH

0112A

OFFICE

STAIR

S2

EXAM

PATIENT TLT

CONFERENCE RM

NURSE

EXAM

EXAM / FLEX M.H.

EXAM

EXAM

CLEAN

MH EXAM

STORAGE

EXAM / FLEX M.H.

M.H. TLT

NURSE

0135A

NURSE / DICTATION

CORRIDOR

C03

MECHANICAL

NF AND PENDING

SERVER FOR ROBOT

SECRETARY

H

J

L

M

M.4

N

A

B

C

DD

EE

HH

FF

JJ

GG

KK

1 2 3 4 5 6

8 9

11 12 13 14 15

AREAS WITH EXISTING FIRE SUPPRESSION

1.

2.

3.

4.

5.

6.

7.

8.

A.

B.

C.

FIRE PROTECTION NOTES

PRIOR TO START OF WORK, CONDUCT THROUGH FIELD SURVEY TO VERIFY EXISTING

CONDITIONS, INCLUDING DETERMINE SIZE, LOCATION AND DETAILS OF EXISTING FIRE

PROTECTION RISERS, MAINS, BRANCHES, COMPONENTS, ALARM VALVES, AND OTHER

SYSTEM ELEMENTS.

IN AREAS OF WORK WITH NO EXISTING FIRE PROTECTION, PROVIDE FIRE PROTECTION,

EXTENDED FROM EXISTING FIRE PROTECTION SYSTEMS.

IN AREAS OF WORK WITH EXISTING FIRE PROTECTION, REWORK EXISTING FIRE

PROTECTION PIPING SYSTEM TO MEET DESIGN DENSITY REQUIREMENTS AND TO

ACCOMMODATE RELOCATED, MODIFIED AND NEW PARTITIONS, AND RELOCATED,

MODIFIED AND NEW CEILINGS. RELOCATE SPRINKLER HEADS AS NEEDED TO

ACCOMMODATE OTHER CEILING ELEMENTS AS NECESSARY WITHIN AREAS OF NEW

WORK. "REWORK" INCLUDES ANY NECESSARY MODIFICATION, DEMOLITION OR

INSTALLATION OF NEW PIPING AND SPRINKLERS TO PROVIDE A COMPLETE AND

OPERATIONAL SYSTEM. WHERE PARTITIONS ARE RELOCATED, REVISED OR NEW,

VERIFY ADEQUATE SPRINKLER COVERAGE ON BOTH SIDES OF PARTITIONS, WHETHER

DENOTED AS WITHIN "AREA OF WORK" OR NOT. REFER TO ARCHITECTURAL FOR AREAS

OF WORK.

FIRE PROTECTION SYSTEMS SHALL BE HYDRAULICALLY DESIGNED IN ACCORDANCE

WITH APPLICABLE NFPA STANDARDS, INCLUDING NFPA 13, AND THE AUTHORITY HAVING

JURISDICTION.

REFER TO SHEET M-001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS.

SUBMIT SHOP DRAWINGS, HYDRAULIC CALCULATIONS AND TECHNICAL DATA SHEETS

FOR ALL EQUIPMENT TO BE INSTALLED TO THE COR. DO NOT START ANY INSTALLATION

WORK UNTIL APPROVAL HAS BEEN RECEIVED.

MAINTAIN PROTECTION IN EXISTING AREAS ADJACENT TO AREAS OF NEW WORK. ANY

NECESSARY SHUTDOWN OF EXISTING SYSTEM SHALL BE COORDINATED AND APPROVED

BY THE VA.

DESIGN DENSITY SHALL BE AS FOLLOWS:

LIGHT HAZARD: 0.10 GPM/SF OVER THE MOST REMOTE 1,500 SF

- OFFICES

- CORRIDORS

- TREATMENT AREAS

- WAITING AREAS

- STORAGE ROOMS UNDER 100 SF

ORDINARY HAZARD GROUP 1: 0.15 GPM/SF OVER THE MOST REMOTE 1,500 SF

- ELECTRICAL ROOMS

- ELECTRICAL CLOSETS

- MECHANICAL EQUIPMENT ROOMS

- ELEVATOR MACHINE ROOMS

ORDINARY HAZARD GROUP 2: 0.20 GPM/SF OVER THE MOST REMOTE 1,500 SF

- STORAGE ROOMS

- LINEN ROOMS

- PHARMACY AND ASSOCIATED STORAGE ROOMS

9.

10.

A.

B.

C.

11.

12.

13.

14.

15.

16.

FURNISH NEW SPRINKLER HEADS, 165° F, ½” ORIFICE.

UNLESS NOTED OTHERWISE:

SPRINKLERS IN AREAS WITH LAY-IN OR HARD CEILINGS SHALL BE SEMI-

RECESSED. SPRINKLER HEADS SHALL BE CENTERED IN 2X2 CEILING TILES, OR

CENTERED IN THE HALF-PANEL OF 4X2 CEILING TILES.

SPRINKLERS IN AREAS OF EXPOSED CONSTRUCTION SHALL BE STANDARD

UPRIGHT.

COORDINATE WITH ARCHITECTURAL TRADES.

PROVIDE 1” AUX DRAIN VALVES WITH HOSE END CONNECTIONS WHERE TRAPPED

SECTIONS OF PIPING ARE INSTALLED.

OBTAIN HYDRANT FLOW TEST OR FIRE PUMP TEST REPORT FROM OWNER. IF A REPORT

FROM WITHIN THE LAST YEAR DOES NOT EXIST, CONTRACTOR IS RESPONSIBLE TO

ARRANGE FOR AND OBTAIN REPORT.

FIRE PROTECTION SYSTEMS, COMPONENTS AND LOCATIONS SHALL BE COORDINATED

THOROUGHLY WITH OTHER TRADES AND EXISTING CONDITIONS PRIOR TO START OF

INSTALLATION. COORDINATE INSTALLATION OF FIRE PROTECTION SYSTEMS, INCLUDING

SUPPORT SYSTEMS, WITH WORK OF MECHANICAL, ARCHITECTURAL AND ELECTRICAL

TRADES, OWNER'S PROCESS EQUIPMENT PROVIDERS, AND EXISTING SYSTEMS,

EQUIPMENT AND BUILDING TRADES.

HANGERS AND SUPPORTS SHALL BE PER NFPA 13. USE OF C-CLAMPS WITHOUT

RETAINING CLIPS IS PROHIBITED. SUPPORT FROM STRUCTURE ONLY.

OFFSET SPRINKLER PIPING AROUND OBSTRUCTIONS AND PROVIDE REQUIRED

CLEARANCE FROM OBSTRUCTIONS FOR ALL AUTOMATIC SPRINKLERS IN ACCORDANCE

WITH NFPA 13. LOCATE PIPING BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING FLOOR-TO-FLOOR HEIGHT IS

10'-0". THOROUGH COORDINATION WITH ALL TRADES IS ESSENTIAL.

THE FOLLOWING SPACES SHALL HAVE "INSTITUTIONAL" TYPE QUICK RESPONSE

SPRINKLER HEADS: EXAM/ FLEX MH ROOMS 0120 & 0121, MH EXAM ROOMS 0123 & 0124;

AND MH TOILET ROOM 0122.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:1

P

M

FX101

FIRE SUPPRESSION PLAN GROUND

FLOOR

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

NORTH

3/32" = 1'-0"

FIRE PROTECTION PLAN GROUND FLOOR

SCALE:

NORTH

3/64" = 1'-0"

FIRE PROTECTION PLAN GROUND FLOOR EXISTING

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - GROUND FLOOR

1" PIPE (AS REQUIRED)

90° ELL

1" NIPPLE

2"x2"x1" TEE BRANCH

LINE (SIZE VARIES)

1/2"x1" REDUCER

165° PENDANT

SPRINKLER HEAD

CEILING PLATE

CEILING TILE

1" PIPE AS REQUIRED

90° ELL

6"

TYP

PLATE WASHER (TYP

TOP AND BOTTOM)

ADJ. SWIVEL

RING.

ANVIL FIG. 69

SEE PLAN FOR PIPE SIZE

THREADED

ROD

ANVIL FIG. 146

FLAT WASHERS FOR

THREADED ROD (TYP

TOP AND BOTTOM)

BEAM CLAMP

UNISTRUT MODEL NO.

DOUBLE HEX NUT

UNISTRUT CHANNEL

MODEL NO.

P2000KO

PURLIN SPACING (FIELD VERIFY)

EXISTING ROOF

PURLIN

(FIELD VERIFY SIZE)

THREADED ROD

ADJ. SWIVEL

RING

PIPE HANGER

EXTENSION PIECE

TOP BEAM CLAMP

DOUBLE HEX NUT

ADJUSTABLE

CLEVIS

TYPE PIPE HANGER

EXISTING ROOF

PURLIN

FIELD VERIFY SIZE

ADJUSTABLE BEAM CLAMP

EXTENSION PIECE

THREADED ROD

THREADED ROD

BEAM CLAMP UNISTRUT

MODEL NO. 2867

ADJ. SWIVEL RING.

PLATE WASHER

(TYP TOP AND

BOTTOM)

DOUBLE HEX NUT

FLAT WASHERS FOR

THREADED ROD (TYP

TOP AND BOTTOM) UNISTRUT CHANNEL

MODEL NO. P2000KO

ADJ. CLEVIS

PURLIN SPACING (FIELD VERIFY)

THREADED ROD

ADJ. SWIVEL RING

PIPE HANGER

TOP BEAM CLAMP

C-CLAMP

RETAINING STRAP

EXISTING ROOF

PURLIN

(FIELD VERIFY SIZE)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:2

P

M

FX501

FIRE SUPPRESSION DETAILS RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

NOT TO SCALE

SPRINKLER DROP

NOT TO SCALE

PIPING HANGER

NOT TO SCALE

UTILITY PIPING HANGER

NOT TO SCALE

UTILITY PIPING HANGER

NOT TO SCALE

UTILITY PIPING HANGER

NOT TO SCALE

UTILITY PIPING HANGER

HWR

W R

HWR

HW

H W

HW

CW

C W

CW

H

J

L

M

M.4

N

M.1

13.3

A

B

C

DD

3.8 4.9 5.3 5.7 6.5 10.6 10.8 11.3 11.8 11.9 13.2

EE

HH

FF

JJ

GG

KK

1 2 3 4 5 6

8 9

11 12 13 14 15

REMOVE PLUMBING IN HATCHED AREAS, CAP BRANCH

LINES AT MAIN, CAP SAN FLUSH WITH SLAB -

COORDINATE WITH SCOPE OF NEW WORK

AREA NOT IN SCOPE

REMOVE SINK,

PREPARE

BRANCH PIPING

FOR

RECONNECTION

CAP 4" DWC & 6" FP

STUB-UPS FLUSH

WITH SLAB, PROVIDE

FLOOR MARKER,

WORK TO BE DONE

ON WEEKENDS

(E) 4"ø DCW

(E) 6"ø FP

CAP FD FLUSH

WITH SLAB

CAP DCW LINE AT BRANCH

MAIN ABOVE CEILING

REWORK SANITARY

RISER TO BE WITHIN

NEW COLUMN

ENCLOSURE, CAP

ABANDONED PIPING

ABOVE CEILING

REWORK SANITARY

RISER, COORD W/

SCOPE OF NEW

WORK

(E) MAINS

TO REMAIN

(E) DCW, DHW,

DHWR BRANCH

MAINS TO REMAIN

(E) BRANCH

MAINS TO

REMAIN

(E) PIPING AND CONDUIT TO

BE REWORKED IN THIS AREA

TO COORDINATE WITH NEW

DUCT AND UTILITIES

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

3. CONTRACTOR TO PERFORM THOROUGH SURVEY OF

EXISTING PLUMBING SYSTEM AND COMPONENTS TO

VERIFY EXISTING CONDITIONS.

4. DEAD LEGS ARE PROHIBITED. ANY DCW OR DHWS BRANCH

LINES NOT SERVING FIXTURES SHALL BE CAPPED AT THE

MAIN.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:5

P

M

PD101

PLUMBING DEMOLITION PLAN

GROUND FLOOR

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

NORTH

3/32" = 1'-0"

PLUMBING DEMOLITION PLAN GROUND FLOOR

(E) DCW, DHW,

DHWR BRANCH

MAINS TO REMAIN

(E) DCW, DHW,

DHWR BRANCH

MAINS TO REMAIN

UG

SCALE:

NORTH

1" = 50'-0"

J

L

M

M.4

N

M.1

13.3

A

B

C

DD

3.8 4.9 5.3 5.7 6.5 10.6 10.8 11.3 11.8 11.9 13.2

EE

HH

FF

JJ

GG

KK

1 2 3 4 5 6

8 9

11 12 13 14 15

PP403

PP402

PP401

(E) 4"ø SAN

(E) 4"ø SAN

RELOCATE 4"

SAN RISER

1. REFER TO SHEET M-001 FOR GENERAL NOTES

AND ABBREVIATIONS.

2. REFER TO FIXTURE CONNECTION SCHEDULE ON

SHEET PP501.

3. GRAVITY PIPING SHALL BE SLOPED A MINIMUM OF

1/8" PER FOOT IN THE DIRECTION OF FLOW.

4. FINISHED FLOOR ELEVATION: 100'-0".

NOTES

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:1

P

M

PP100

PLUMBING PLAN UNDERGROUND

COMPOSITE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

NORTH

3/32" = 1'-0"

PLUMBING PLAN UNDERGROUND COMPOSITE

SCALE:

NORTH

1" = 50'-0"

J

L

M

M.4

N

M.1

13.3

A

B

C

DD

3.8 4.9 5.3 5.7 6.5 10.6 10.8 11.3 11.8 11.9 13.2

EE

HH

FF

JJ

GG

KK

1 2 3 4 5 6

8 9

11 12 13 14 15

PP411

PP412

PP413

REWORK SANITARY

AS REQ'D TO RE-

ROUTE SAN RISER

4" SAN DN

(E) 4"ø SAN

UP & DN

(E) 4"ø SAN

(E) 4"ø SAN

PP414

(E) DCW,

DHW, DHWR

TO REMAIN

(E) PIPING AND CONDUIT TO

BE REWORKED IN THIS AREA

TO COORDINATE WITH NEW

DUCT AND UTILITIES; COORD

WITH ALL TRADES PRIOR TO

START OF WORK

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. SANITARY PIPING SHALL SLOPE MINIMUM 1/8" PER FOOT IN

THE DIRECTION OF FLOW.

5. REFER TO FIXTURE CONNECTION SCHEDULE ON SHEET

PP501.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

NOTES

AREA NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:4

P

M

PP101

PLUMBING PLAN GROUND FLOOR

COMPOSITE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

NORTH

3/32" = 1'-0"

PLUMBING PLAN GROUND FLOOR COMPOSITE

SCALE:

NORTH

1" = 50'-0"

J

L

M

M.4

N

M.1

HH

JJ

GG

KK

1 2 3 4 5 6 7 8

(E

"ø

S A

N

(E) 4"ø SAN

(E

"ø

S A

N

(E) 3"ø SAN

CAP VENT LINE

FLUSH WITH SLAB

(E) FD

3" SAN UP

1 1/2" SAN UP TO SINK

3"ø SAN

UP TO

WC

1 1/2" SAN UP TO LAV

UP TO SS

UP TO FD

3" SAN UP

UP TO

CO

4"ø SAN

"ø

S A

N

4"ø SAN

4" SAN UP

4"ø SAN

4" SAN UP

3"ø SAN

3" SAN UP

4"ø SAN

UP TO CO

3"ø SAN

3"ø SAN

4"ø V UP

(E) 4"ø SAN

(E) CAP

BACKWATER

VALVE

AREA NOT IN SCOPE

1. REFER TO SHEET M-001 FOR GENERAL NOTES

AND ABBREVIATIONS.

2. REFER TO FIXTURE CONNECTION SCHEDULE ON

SHEET PP501.

3. GRAVITY PIPING SHALL BE SLOPED A MINIMUM OF

1/8" PER FOOT IN THE DIRECTION OF FLOW.

4. FINISHED FLOOR ELEVATION: 100'-0".

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:0

P

M

PP401

PLUMBING LARGE SCALE VIEW -

PHARMACY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP100

1/4" = 1'-0"

1 PLUMBING PLAN UNDERGROUND - PHARMACY

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - PHARMACY

L

M

M.4

N

M.1

13.3

HH

JJ

GG

KK

8 9 10 11 12 13 14 15

(E

"ø

S A

N

(E) 4"ø SAN

3" SAN UP

UP TO SINK

UP TO LAV

UP TO WC UP TO WCO

FD

FD

UP TO

SINK

3"ø SAN4"ø SAN

UP TO CO

3"ø SAN

"ø

S A

N

4"ø SAN

UP

UP TO

FCO

4"ø SAN

UP

"ø

S A

N

UP TO

FCO

4"ø SAN

UP

(E

"ø

S A

N

"ø

S A

N

4"ø SAN 4"ø SAN

I.E.: 98' - 3"

I.E.: 98' - 0"

I.E.: 98' - 1 3/4"

UP TO LAV

"ø

S A

N

I.E.: 98' - 10 1/2"

I.E.: 98' - 6"

(E) 4"ø SAN

UP

1 1/2"ø SAN 1 1/2"ø SAN

UP

1 1/2"ø SAN

1 1/2"ø SAN

1 1/2"ø SAN

(E) 4"ø SAN

UP

2"ø V UP

2"ø V

UP

(E) 4"ø SAN

(E) 4"ø SAN

(E) 4"ø SAN

AREA NOT IN SCOPE

1. REFER TO SHEET M-001 FOR GENERAL NOTES

AND ABBREVIATIONS.

2. REFER TO FIXTURE CONNECTION SCHEDULE ON

SHEET PP501.

3. GRAVITY PIPING SHALL BE SLOPED A MINIMUM OF

1/8" PER FOOT IN THE DIRECTION OF FLOW.

4. FINISHED FLOOR ELEVATION: 100'-0".

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:1

P

M

PP402

PLUMBING LARGE SCALE VIEW -

OPEN OFFICE AND AUDIOLOGY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP100

1/4" = 1'-0"

1 PLUMBING PLAN UNDERGROUND - OPEN OFFICE AND AUDIOLOGY

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - OPEN OFFICE AND AUDIOLOGY

13.3

A

B

C

DD

10.6 10.8 11.3 11.8 11.9 13.2

EE

FF

GG

8 9 10

11 12 13

14 15

(E) 4"ø SAN

(E

"ø

S A

N

(E) 4"ø SAN

(E) 4"ø SAN

(E) 4"ø SAN

(E) 4"ø SAN

(E

"ø

S A

N

(E

"ø

S A

N

"ø

S A

N

"ø

S A

N

"ø

S A

N

3"ø SAN

"ø

S A

N "ø

S A

N

"ø

S A

N

3"ø SAN3"ø SAN

"ø

S A

N

3"ø SAN

(E

"ø

S A

N

(E

"ø

S A

N

"ø

S A

N

(E) 3"ø SAN(E) 4"ø SAN(E) 4"ø SAN

(E

"ø

S A

N (E

"ø

S A

N

(E) 4"ø SAN

4"ø SAN

UP TO WC

UP TO WC

UP TO

2 LAV

UP TO (E) CO -

SET TO NEW FIN

FLR AS REQ'D

(E

"ø

S A

N

UP TO (E) CO -

SET TO NEW FIN

FLR AS REQ'D

UP TO SINK

UP TO SINK

UP TO CLINICAL

SERVICE SINK

UP TO SINK

UP TO SINK

UP TO SINK

UP TO (E) CO -

SET TO NEW FIN

FLR AS REQ'D

UP TO FCO

UP TO SINK

UP TO LAV

FD

UP TO SINK

3"ø SAN

UP TO SS

UP TO CO

UP TO FD

1 1/2"ø SAN

(E) CO

(E) 4"ø SAN

CAPPED

AT FLR

(E) 1 1/2"ø SAN

CAPPED

AT FLR

(E) CO

(E) CO

(E) 1 1/2"ø SAN

(E) 1 1/2"ø SAN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

(E) 1 1/2"ø SAN

CAPPED

FLUSH W/

SLAB

CAPPED

FLUSH W/

SLAB

CAPPED

FLUSH W/

SLAB

CAPPED

FLUSH W/

SLAB

CAPPED FLUSH

W/ SLAB

(E) 1 1/2"ø SAN

CAPPED

AT FLR

(E) 1 1/2"ø SAN

CAPPED AT FLR

(E) 4"ø SAN

(E) 1 1/2"ø SAN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

CAPPED AT FLR

CAPPED FLUSH

W/ SLAB

CAPPED FLUSH

W/ SLAB

(E) 1 1/2"ø SAN

(E) 4"ø SAN (E) 1 1/2"ø SAN

CAPPED AT FLR

CAPPED AT FLRCAPPED

AT FLR

(E) CO

(E) 1 1/2"ø SAN

CAPPED AT FLR

(E) 4"ø SAN

UP

1 1/2"ø SAN

1 1/2"ø SAN

1 1/2"ø SAN

UP TO SINK

1 1/2"ø SAN

1 1/2"ø SAN

1 1/2"ø SAN

(E) 4"ø SAN

UP

1 1/2"ø SAN

1 1/2"ø SAN

1 1/2"ø SAN

INSTALL CO ON

(E) SAN LEVEL

WITH FIN FLR

CAPPED

BELOW FIN

FLR

4"ø SAN UP

FD

1 1/2"ø SAN

UP TO SINK

3"ø SAN

3"ø SAN

1 1/2"ø SAN

UP TO SINK

1 1/2"ø SAN

UP TO LAV

4"ø SAN

UP TO WC

4"ø SAN

3"ø SAN

CAPPED AS

REQ'D FOR

NEW WORK

1 1/2"ø SAN

4"ø SAN

UP TO LAV

UP TO WC

1 1/2"ø SAN

1 1/2"ø SAN

1 1/2"ø SAN

UP TO SINK

UP TO SINK

UP TO SINK

1 1/2"ø SAN

UP TO SINK

1 1/2"ø SAN

UP TO SINK

"ø

S A

N

3"ø SAN

4"ø SAN

3"ø SAN

3"ø SAN

UP TO WC

4"ø SAN

2"ø V

UP

1 1/2"ø V

UP

1 1/2"ø V

UP

(E) 1 1/2"ø SAN

TO SITE SANITARY

1 1/2"ø V UP

4"ø SAN

4"ø SAN

AREA NOT IN SCOPE

1. REFER TO SHEET M-001 FOR GENERAL NOTES

AND ABBREVIATIONS.

2. REFER TO FIXTURE CONNECTION SCHEDULE ON

SHEET PP501.

3. GRAVITY PIPING SHALL BE SLOPED A MINIMUM OF

1/8" PER FOOT IN THE DIRECTION OF FLOW.

4. FINISHED FLOOR ELEVATION: 100'-0".

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:2

P

M

PP403

PLUMBING LARGE SCALE VIEW -

URGENT CARE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP100

1/4" = 1'-0"

1 PLUMBING PLAN UNDERGROUND - URGENT CARE

5. FOR SINKS AND LAVATORIES WITH BASINS INTEGRAL TO

COUNTERS, MILLWORK OR FURNITURE SYSTEMS,

COORDINATE PLUMBING CONNECTION LOCATIONS WITH

SUPPLIER(S) AND ARCHITECTURAL TRADES.

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - URGENT CARE

L

M

M.4

N

M.1

HH

JJ

GG

KK

1 2 3 4 5 6 7 8

1 1/2"ø SAN

(E

/2 "ø

S A

N

(E) 1 1/2"ø SAN

2"ø SAN

1 1/2"ø SAN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

(E) 1 1/2"ø SAN

(E) 1 1/2"ø SAN

P-528

P-101

2" SAN DN

CO

FD

3/4"ø DHWS

3/4"ø DCW

(E) 1 1/2"ø SAN UP

P-418

1 1/2"ø DCW

3/4"ø DHWS 3/4"ø DHWR

3/4"ø DHWS

3/4"ø DCW

P-502

CO

(E) 1 1/2"ø SAN

(E) 1 1/2"ø SAN

(E) 4"ø SAN

(E) 3"ø SAN

(E) 1 1/2"ø SANUP

4"ø SAN

P-TRAP

UP

UP

3/4"ø DHWR

3/4"ø DHWS

1 1/2"ø DCW

3/4"ø DHWR

1"ø DHWS

2"ø DCW

(E) 1"ø DHWR

(E) 2"ø DHWS

(E) 3"ø DCW

(E) 2"ø DHWS

(E) 1"ø DHWR (E) 3"ø DCW

4"ø SAN

DN

4"ø SAN

DN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

(E) 3"ø SAN

UP

UP UP

CO

P-TRAP

(E) 3"ø SAN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

UP

UP

P-TRAP

CO4"ø SAN

DN

CO

(E) 1 1/2"ø SAN

3"ø SAN

DN

CO

P-531 & P-712, CONNECT TO (E) DCW,

DHW, SAN & V

(E) FD

(E) 4"ø V

UP

4"ø V

4"ø V DN

1 1/2"ø V 2"ø V 2"ø V

2"ø V

(E) 2"ø V

(E) 3"ø V

UP

PROVIDE A 3/4" VALVED OUTLET

AT WALL ADJACENT TO SINK FOR

FUTURE COFFEE MAKER

UP

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. SANITARY PIPING SHALL SLOPE MINIMUM 1/8" PER FOOT IN

THE DIRECTION OF FLOW.

5. REFER TO FIXTURE CONNECTION SCHEDULE ON SHEET

PP501.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:4

P

M

PP411

PLUMBING LARGE SCALE VIEW -

PHARMACY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP101

1/4" = 1'-0"

1 PLUMBING PLAN GROUND FLOOR - PHARMACY

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - PHARMACY

L

M

M.4

N

M.1

13.3

HH

JJ

GG

KK

8 9 10 11 12 13 14 15

P-528

3/4"ø DHWS 3/4"ø DCW

P-532

WCO

P-101

P-711

FD

FD

P-418

3/4"ø DCW 3/4"ø DHWS

1"ø DCW 1"ø DHWS

1 1/2"ø DCW

P-532

3/4"ø DCW

3/4"ø DHWS

3/4"ø DHWS

3/4"ø DCW

3/4"ø DCW

3/4"ø DHWS

(E) 4"ø SAN

UP & DN

FCO

FCO

(E) 1 1/2"ø SAN

UP

1 1/2"ø SAN

DN TO UG

(E) 1 1/2"ø SAN

1 1/2"ø SAN

UP

DN TO UG

(E) 1 1/2"ø SAN

UP

4"ø SAN

DN TO UG

(E) 3"ø SAN

(E) 4"ø SAN

UP TO FD

UP

(E

"ø

S A

N

(E) 3"ø SAN

(E) 1 1/2"ø SAN

(E) 3"ø SAN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

UP

UP

UP

UP TO FD

CO

4"ø SAN

DN TO UG

(E) 1 1/2"ø SAN

(E) 3"ø SAN

(E) 4"ø SAN

(E) 1 1/2"ø SAN

4"ø SAN

UP

UP

UP TO FD

UP

DN TO UG

2"ø V2"ø V

DN TO UG

2"ø V

DN TO UG

PROVIDE A 3/4" VALVED

OUTLET AT WALL

ADJACENT TO SINK FOR

FUTURE COFFEE MAKER

(E) 3"ø DCW

(E) 3"ø DHWR

(E) 3"ø DHWS

FCO

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. SANITARY PIPING SHALL SLOPE MINIMUM 1/8" PER FOOT IN

THE DIRECTION OF FLOW.

5. REFER TO FIXTURE CONNECTION SCHEDULE ON SHEET

PP501.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:5

P

M

PP412

PLUMBING LARGE SCALE VIEW -

OPEN OFFICE AND AUDIOLOGY

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP101

1/4" = 1'-0"

1 PLUMBING PLAN GROUND FLOOR - OPEN OFFICE AND AUDIOLOGY

KEYNOTES

FIELD ROUTE VENT BRANCH LINE AND CONNECT TO

(E) 2" VENT MAIN.

SCALE:

NORTH

1" = 50'-0"

KEY PLAN - OPEN OFFICE AND AUDIOLOGY

A

B

C

DD

10.6 10.8 11.3 11.8 11.9 13.2

EE

FF

GG

8 9 10

11 12 13

14 15

(E) 3"ø DCW

(E) 3"ø DHWS

(E) 2"ø DCW

(E) 2"ø DHWS

(E) 2 1/2"ø DHWS

(E) 2 1/2"ø DCW

(E) 1 1/2"ø DHWS

(E) 2"ø DCW

1 1/4"ø DHWS

2"ø DCW

1"ø DHWS

1 1/2"ø DCW

3/4"ø DHWS 3/4"ø DCW

3/4"ø DHWS

3/4"ø DCW

1"ø DHWS

1 1/2"ø DCW

1"ø DHWS

1 1/2"ø DCW

3/4"ø DHWS

1 1/2"ø DCW

P-502

3/4"ø DCW 3/4"ø DHWS

3/4"ø DHWR

CIRCUIT SETTER

SET TO 0.5 GPM

1 1/2"ø DCW 1 1/4"ø DHWS

P-101

P-418

1 1/2"ø DCW

3/4"ø DHWS

2"ø DCW

(E) 3"ø DHWR

3/4"ø DHWR

(E) 2 1/2"ø DHWR

(E) 2 1/2"ø DHWR

P-418

(E) 1"ø DHWR

3/4"ø DCW 3/4"ø DHWS

P-418 P-404

3/4"ø DCW

3/4"ø DHWS

P-505

P-532

3/4"ø DHWS

3/4"ø DCW

P-404

3/4"ø DCW 3/4"ø DHWS

(E) 1"ø DHWR

(E) 1 1/2"ø DHWS

(E) 2"ø DCW

P-404

P-935

P-910

3/4"ø DHWR

(E) 1 1/2"ø DCW

(E) 1"ø DHWS

(E) 1"ø DHWR

(E) 2"ø DCW

(E) 2"ø DHWS

(E) 2"ø DHWR

P-533

P-404

P-711

FD

P-418

P-101

P-404

3/4"ø DHWS

3/4"ø DCW

1"ø DHWS

1 1/2"ø DCW

P-404

P-404

3/4"ø DCW

3/4"ø DHWS

P-404

3/4"ø DCW

3/4"ø DHWS

3/4"ø DHWS

3/4"ø DCW

1 1/2"ø DCW

1 1/4"ø DHWS

CIRCUIT SETTER,

SET TO 0.5 GPM

FCO

FD

(E)FCO

(E) 2 1/2"ø DHWS

(E) 2 1/2"ø DCW

P-101

P-418

P-404

P-533

P-404

(E) 4"ø SAN

(E) 2"ø SAN

(E) 3"ø SAN

4"ø SAN

(E) 3"ø SAN

UP

UP

UP

DN TO UG

FD

1 1/2"ø V

FCO

1 1/2"ø V

1 1/2"ø V

2"ø V

2"ø V

DN TO

UG

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

1 1/2"ø V

11 1/2"ø V

1 1/2"ø V

SHUT-OFF

VALVE (TYP)

PROVIDE BFP AND PIPING TO

ICE MAKER/ BEVERAGE

DISPENSER, REFER TO

DETAIL

(E)FCO

(E)FCO

(E)FCO

(E)FCO

(E)FCO

1"ø DCW

3/4"ø DCW1 1/2"ø DCW

1 1/2"ø DCW

3/4"ø DHWS

1"ø DHWS

1"ø DHWS

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. SANITARY PIPING SHALL SLOPE MINIMUM 1/8" PER FOOT IN

THE DIRECTION OF FLOW.

5. REFER TO FIXTURE CONNECTION SCHEDULE ON SHEET

PP501.

6. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

7. REFER TO ARCH GENERAL SERIES SHEETS FOR RATED

WALLS, TEMPORARY PARTITIONS, AND PHASING.

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:1

P

M

PP413

PLUMBING LARGE SCALE VIEW -

URGENT CARE

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP101

1/4" = 1'-0"

1 PLUMBING PLAN GROUND FLOOR - URGENT CARE

KEYNOTES

FIELD ROUTE VENT BRANCH LINE AND CONNECT TO

(E) 2" MIN VENT MAIN.

SCALE:

NORTH

1" = 50'-0"

A

B

C

DD

10.6 10.8 11.3 11.8 11.9 13.2

EE

FF

GG

8 9 10

11 12 13

14 15

(E) 3/4"ø O2

3/4"ø O2 3/4"ø MVAC

MED GASES

DN TO ZONE

VALVE BOX

3/4"ø MVAC

3/4"ø O2

MED GASES DN TO

(1) O2 OUTLET AND

(1) MVAC INLET IN

EXAM ROOM

(E) 3/4"ø O2

3/4"ø O2

3/4"ø MVAC

MED GASES DN TO

ZONE VALVE BOX

MED GAS

ALARM PANEL

MED GAS

ALARM PANEL

(E) 3/4"ø O2

3/4"ø MVAC

3/4"ø O2

3/4"ø MVAC

3/4"ø O2

3/4"ø O2 3/4"ø MVAC

3/4"ø MVAC 3/4"ø O2

MED GASES DN

TO (1) O2 OUTLET

AND (1) MVAC

INLET IN EACH

EXAM ROOM

MED GASES DN TO

(1) O2 OUTLET AND

(1) MVAC INLET IN

EXAM ROOM

MED GASES DN TO

(1) O2 OUTLET AND

(1) MVAC INLET IN

EXAM ROOM

MED GASES DN TO

(1) O2 OUTLET AND

(2) MVAC INLETS IN

PROCEDURE ROOM

MED GASES DN TO

(1) O2 OUTLET AND

(2) MVAC INLETS IN

PROCEDURE ROOM

MED GASES DN TO

(1) O2 OUTLET AND

(2) MVAC INLETS IN

PROCEDURE ROOM

MED GASES DN TO

(1) O2 OUTLET AND

(1) MVAC INLET IN ISO

ROOM

(E) 1"ø MVAC

FIELD VERIFY LOCATION OF

EXISTING VACUUM PIPING

MAIN

FIELD VERIFY LOCATION OF

EXISTING OXYGEN PIPING

MAIN

(E) 1" MVAC,

CONTINUES TO

SOURCE

(E) 3/4" O2, CONTINUES TO

SOURCE

(E) 1" MVAC,

CONTINUES TO

OTHER LOADS

(E) 3/4" O2, CONTINUES TO

OTHER LOADS

(E) 3/4" O2, CONTINUES TO

OTHER LOADS

AREA NOT IN SCOPE

1. WORK WHICH WILL AFFECT FIRST FLOOR ABOVE SHALL BE

DONE AT NIGHT OR ON WEEKENDS. COORDINATE WITH

THE COR.

2. HOLD ALL UTILITIES UP AS HIGH AS POSSIBLE, LOCATING

BETWEEN AND THROUGH JOISTS WHERE POSSIBLE.

CEILING SPACE IS EXCEEDINGLY CONGESTED - EXISTING

FLOOR-TO-FLOOR HEIGHT IS 10'-0". THOROUGH

COORDINATION WITH ALL TRADES IS ESSENTIAL.

3. REFER TO SHEET M-001 FOR GENERAL NOTES AND

ABBREVIATIONS.

4. OFFSET PIPING AS REQUIRED TO AVOID INTERFERENCES

WITH STRUCTURE AND OTHER TRADES. NOT ALL

REQUIRED OFFSETS WHICH MAY BE REQUIRED ARE

INDICATED - CONTRACTOR TO COORDINATE WITH EXISTING

CONDITIONS AND ALL TRADES.

5. IN NO CASE SHALL ANY MEDICAL GAS PIPING BE LESS THAN

1/2". IN NO CASE SHALL ANY MEDICAL VACUUM PIPING BE

LESS THAN 3/4".

NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:2

P

M

PP414

PLUMBING LARGE SCALE VIEW -

URGENT CARE - MEDICAL GAS

RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

SCALE:

PP101

1/4" = 1'-0"

1 PLUMBING PLAN GROUND FLOOR - URGENT CARE - MEDICAL GASES

KEYNOTES

Medical Gases NO Smoking or Open Flame

PROVIDE LABEL FOR THE GAS BOTTLE STORAGE

ROOM. COORDINATE WITH THE GOVERNMENT'S

SIGNAGE PROVIDER. SIGN SHALL READ:

SCALE:

NORTH

1" = 50'-0"

INSTALL ZONE VALVE BOXES PER MANUFACTURER'S RECOMMENDATIONS.

FRONT VIEW

WALL

FIN. FLR.

SIDE VIEW

50"

SHUT-OFF

VALVE (TYP)

PRESSURE

GAUGE (TYP)

CL

NOTE:

REFER TO PLANS FOR PIPE

SIZES & DESIGNATIONS.

MEDICAL

GASES FROM

SOURCE

BRANCHES

MEDICAL

GASES TO

ROOMS

DOUBLE ZONE

VALVE BOX

SINGLE COMPARTMENT SINK

LAV 1/2" 1/2" 1 1/2" 1 1/2"

1 1/2"1/2"1/2" 1 1/2"

3" 1 1/2"SS SERVICE SINK 2" 3/4"

LAVATORY

FS -- -FLOOR SINK

NOTES:

1.

2.

3.

4.

PLUMBING FIXTURE SCHEDULE

VENTWASTE

HOT WATER/

TEMPERED

(DHW)

COLD

WATER

(DCW)

POINT CONNECTION

PLUMBING FIXTUREMARK

WC 1 1/4" 2"4"-

4"

NOTE 2

SK

WATER CLOSET

FD FLOOR DRAIN - -

3"

NOTE 2

3" 1 1/2"CSS CLINICAL SERVICE SINK 1 1/4" 3/4"

WH -3/4" -FREEZELESS

WALL HYDRANT

INSTALL FIXTURES PER MANUFACTURER'S INSTRUCTIONS TO MEET

BARRIER FREE REQUIREMENTS, AND PER CODE.

FURNISH AND INSTALL A DEEP SEAL TRAP WITH 4" SEAL AND 1/2" TRAP

PRIMER PIPING.

PROVIDE EACH LAVATORY, SINK AND SHOWER WITH POINT-OF-USE

THERMOSTATIC MIXING VALVE. ALL POINT-OF-USE MIXING VALVES

SHALL BE IN ACCORDANCE WITH APPLICABLE ASSE STANDARD.

PROVIDE SHUT-OFF VALVE ON SUPPLY LINES TO EACH FIXTURE

GROUP.

EWC -1/2" 1 1/2"ELECTRIC WATER

COOLER

1 1/2"

SH SHOWER 3/4" 3/4" --

STEAM, GAS, OR AIR PIPING

BRANCH SECTIONALIZING

VALVE, OR EQUIPMENT

SHUT-OFF VALVE

SUPPLY MAIN

BRANCH PIPING

OFF TOP OF MAIN

WATER PIPING

BRANCH SECTIONALIZING

VALVE, OR EQUIPMENT

SHUT-OFF VALVE

SUPPLY OR

RETURN MAIN

BRANCH PIPING OFF

BOTTOM OF MAIN

NOTE: BRANCHES MAY BE 45 OR 90 DEGREES ABOVE/BELOW MAIN

STEEL PIPE

SLEEVE AS

REQUIRED

FIRE RATED

PARTITION

UNINSULATED PIPE

REFER TO UL APPROVED

MFG LITERATURE FOR

SPECIFIC PRODUCT

LIMITATIONS.

FIRESTOP SEALANT

SEE MANUFACTURER

LITERATURE FOR DEPTH

FIRESTOP SEALANT OF

SLEEVE PENETRATION BY

OTHERS WHERE

REQUIRED

FIRESTOP SEALANT

SEE MANUFACTURER

LITERATURE FOR DEPTH

STEEL PIPE

SLEEVE WHERE

REQUIRED

FIRE RATED

PARTITION

REFER TO UL APPROVED

MFG LITERATURE FOR

SPECIFIC PRODUCT

LIMITATIONS.

PIPING

PIPE INSULATION

FIRESTOP SEALANT OF

SLEEVE PENETRATION BY

OTHERS WHERE REQUIRED

ENTENTES TO SEWER LINE

NOTE:

PIPING AND JOINT TYPE PER SPECIFICATIONS

EXTERIOR

PROVIDE NICKEL BRONZE FLOOR

PLATE TO BE COMPATIBLE

W/ TYPE FLOOR INSTALLED

EXTENSION TO

SOIL OR WASTE

LINE

JOINT TYPE

PER SPECS

FINISHED FLOOR OR PAVED

AREA. PROVIDE 18"x18"x8"

CONCRETE PAD WHEN

FINISHING AT GRADE

FLOOR WALL

SOIL OR WASTE

CLEANOUT TEE

CHROME PLATED

BRONZE WALL PLATE

JOINT TYPE

PER SPECS

BRASS PLUG

CLEANOUT

ACCESS

COVER

SANITARY OR

STORM PIPING,

SLOPED IN

DIRECTION OF FLOW

AT SLOPE NOTED

ON PLANS

CAST IRON

CLEANOUT FERRULE

AND PLUG

FINISHED FLOOR OR PAVED

AREA PROVIDE 18" x 18"x 6"

CONCRETE PAD WHEN

FINISHING AT GRADE.

BALL VALVES

1 1/2" VENT

1/2" DHWS

3/4" DCW

1/2" DCW

1/2" DHWS &

DCW TO SINK

1 1/2" SAN

FILTER WITH

GAUGES AND

BALL VALVE

INSTALL TRAP PRIMER

BEHIND 8" SQUARE

STAINLESS STEEL

ACCESS PANEL

M

IN

SECURE TUBING DRAIN

LINES TO UNDERSIDE OF

COUNTER TOP & TERMINATE

OF TRAPPED SAN INLET

1 1/2" SAN

FIN FLR

CEILING

WALL

3/4" DCW

1 1/2" VENT

ICE

MAKER

ICE MAKER

FILTER

TUBING DRAINS

2" AIR GAP

1 1/2" SAFE WASTE

DRAIN WITH TRAP,

CONNECT TO VENTED

SAN RISER IN WALL

1 1/2" VENTED

SAN RISER

FIN FLR

CEILING

FOOT PEDAL

FLUSH VALVE

1 1/2" VENT

3/4" DHWS

1 1/4" DCW

1 1/4"

3/4"

1/2"

PEDAL VALVE

SUPPORT

BRACKET

VACUUM

BREAKER

FIN FLR

CEILING

FIXTURE

SUPPORT

3" WASTE

NOTES:

INSTALL FIXTURE AND COMPONENTS PER MANUFACTURER'S GUIDELINES AND INSTRUCTIONS.

RINSE UNIT TO

DRIP OVER SINK

AND BE LONG

ENOUGH TO

EXTEND TO

SINK RIM

SERVICE

SINK FAUCET

PEDAL VALVE

FOOT PEDAL

FLUSH VALVE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

GUIDON DESIGN INC. | 1221 N PENNSYLVANIA SUITE 200 | INDIANAPOLIS, IN 46202

317.800.6388 | WWW.GUIDONDESIGN.COM

GHAFARI ASSOCIATES LLC. | 17101 MICHIGAN AVENUE | DEARBORN, MI 48126

313.441.3000 | WWW.GHAFARI.COM

C g h a fa ri l o c a l c a c h e

\R e v it \1

M

C

E N

T R

A L p e la y y a n .r v t

/1

/2

:4

:4

P

M

PP501

PLUMBING PIPING DETAILS RENOVATE PHARMACY &

URGENT CARE

5500 Armstrong Road, Battle Creek

515-18-109

05/20/20 MAP PME

100% BID DOCUMENTS

PART. SPRINKLERED

100% BID DOCUMENTS

NOT TO SCALE

MEDICAL GASES ZONE VALVE BOX

NOT TO SCALE

PLUMBING BRANCH CONNECTIONS

NOT TO SCALE

PENETRATION - FIRESTOPPED UNINSULATED PIPE THRU RATED PARTITION

NOT TO SCALE

PENETRATION - FIRESTOPPED INSULATED PIPE THRU RATED WALL

NOT TO SCALE

CLEANOUTS

NOT TO SCALE

CLEANOUT DETAIL

NOT TO SCALE

COUNTER-TOP BEVERAGE DISPENSER OR ICE MAKER PIPING

NOT TO SCALE

CLINICAL SERVICE SINK PIPING DIAGRAM - WALL MOUNT PEDAL FLUSH

F

T

TS

H

S

PD

SP

TS

FS

1.

2.

3.

4.

5.

6.

7.

GENERAL MECHANICAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

GENERAL HVAC NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

A.

B.

GENERAL HVAC PIPING NOTES

FINAL ELECTRICAL POWER CONNECTIONS TO ALL MECHANICAL EQUIPMENT SHALL BE BY

ELECTRICAL TRADE.

FINAL GAS CONNECTIONS TO ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED BY

PLUMBING TRADE.

ALL FIELD CONTROL WIRING AND INTERLOCK WIRING SHALL BE FURNISHED AND

INSTALLED BY TEMPERATURE CONTROL TRADES. FOR EXAMPLE, WIRING FROM

CONTROL PANEL TO CONTROLLED DEVICE SHALL BE SHOWN AND INSTALLED BY

TEMPERATURE CONTROL TRADES.

KEEP ALL EXHAUST AIR AND SANITARY VENTS AWAY FROM OUTSIDE AIR INTAKE, AT

LEAST A MINIMUM OF 10 FEET.

MECHANICAL CONTRACTOR SHALL COORDINATE ALL OPENINGS IN MASONRY/PRE-CAST

WALLS WITH MASON/PRE-CAST CONTRACTOR.

MECHANICAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL TRADES

PAINTING OF ALL EXPOSED DUCTWORK, DIFFUSERS AND PIPING/INSULATION.

ACCESS DOORS: PROVIDE ACCESS DOORS FOR ALL EQUIPMENT THAT REQUIRES

ROUTINE MAINTENANCE OR SERVICE; AND THAT IS CONCEALED BEHIND NON-

ACCESSIBLE WALL OR CEILING CONSTRUCTION. TYPICALLY ACCESS PANELS ARE NOT

SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING

AND SIZING OF ACCESS DOORS TO PERMIT REQUIRED ACCESS FOR ROUTINE

MAINTENANCE OPERATIONS.

1.

2.

3.

4.

5.

6.

GENERAL DEMOLITION NOTES

DEMOLITION OF EACH SYSTEM SHALL INCLUDE ALL ACCESSORIES (DAMPERS, VALVES,

AND OTHER COMPONENTS), PIPE, DUCT AND EQUIPMENT SUPPORTS, AS WELL AS ALL

EXISTING ABANDONED EQUIPMENT AND MATERIALS WHERE SUCH ITEMS ARE NOT

REQUIRED FOR THE PROPER OPERATION OF THE REVISED SYSTEMS.

REMOVE ALL ITEMS INDICATED FOR DEMOLITION. REMOVE ASSOCIATED SUPPORTS,

ACCESSORIES, INSULATION, CONDUIT, WIRING AND CONTROLS. POWER AND CONTROL

WIRING SHALL BE REMOVED BACK TO SOURCE. PIPING AND DUCTWORK SHALL BE

CAPPED AT MAIN, UNLESS SHOWN OTHERWISE.

DURING DEMOLITION AND CONSTRUCTION, PROTECT EQUIPMENT, PIPING, DUCTWORK,

ACCESSORIES, SUPPORTS, AND OTHER EXISTING SYSTEMS THAT ARE TO REMAIN.

PROTECT ALL EQUIPMENT, DUCT, AND PIPE ENDS OF COMPONENTS TO REMAIN WITH

TEMPORARY CLOSURES DURING DEMOLITION WORK.

EXCEPT FOR ITEMS IDENTIFIED AS BEING TURNED OVER TO THE OWNER, ALL

DEMOLISHED ITEMS SHALL BE COMPLETELY REMOVED FROM THE SIDE AND PROPERLY

DISPOSED OF BY CONTRACTOR.

SERVICES TO ADJACENT AREAS SHALL BE MAINTAINED DURING DEMOLITION AND

CONSTRUCTION. PROVIDE MEANS FOR TEMPORARY SERVICES IF REQUIRED IN ORDER

TO PROVIDE FOR CONTINUOUS OPERATIONS.

GENERAL NOTES

1. CONTRACTOR IS RESPONSIBLE TO COMPLETE A THOROUGH FIELD SURVEY OF THE AREA

OF WORK. CONTRACTOR MUST CONDUCT A SITE SURVEY DURING BID PERIOD TO CONFIRM

EXISTING CONDITIONS AND EXTENTS OF SCOPE.

2. VERIFY EXACT SIZE AND LOCATION OF EXISTING UTILITIES BEFORE START OF

CONSTRUCTION.

3. CONNECTIONS TO AND SHUT-DOWNS OF EXISTING SYSTEM SHALL BE COORDINATED WITH

THE VA TO ALLOW MINIMUM INTERFERENCE WITH THE VA'S OPERATIONS AND DOWN TIME

OF EXISTING SERVICES. CONTRACTOR SHALL SUBMIT TO VA FOR REVIEW AND APPROVAL

THE PROPOSED PHASING PLAN FOR CONNECTING NEW SERVICES.

4. IT IS MANDATORY FOR CONTRACTOR TO COORDINATE WITH ALL OTHER MECHANICAL AND

ELECTRICAL TRADES IN REGARDS TO ROUTING OF PIPING IN MECHANICAL ROOMS, SHAFTS,

ABOVE CEILINGS AND ATTIC SPACES.

5. ALL ITEMS THAT REQUIRE ACCESS, SUCH AS FOR OPERATING, CLEANING, SERVICING,

MAINTENANCE, AND CALIBRATION, SHALL BE EASILY AND SAFELY ACCESSIBLE BY PERSONS

STANDING AT FLOOR LEVEL, OR STANDING ON PERMANENT PLATFORMS, WITHOUT THE USE

OF PORTABLE LADDERS. EXAMPLES OF THESE ITEMS INCLUDE, BUT ARE NOT LIMITED TO:

ALL TYPES OF VALVES, FILTERS AND STRAINERS, TRANSMITTERS, CONTROL DEVICES.

PRIOR TO COMMENCING INSTALLATION WORK, REFER CONFLICTS BETWEEN THIS

REQUIREMENT AND…